Home

USER MANUAL

image

Contents

1. Yellow 2 RCV RCV 5 Black Green 3 XMT GNDt 6 White Blue 1 GNDt Connection to ground is optional Standard color codes yours may be different 3 2 CONNECTION TO THE El A TI A 561 SERI AL PORT Every serial device connected to the Model 1000R must have a special interface cable that conforms to the EIA TIA 561 standard On one end this cable must have a male RJ 45 plug on the other end it must have a connector that fits into your serial device The diagram on the following page shows the pin connections for the Model 1000R Connect each pin to the appropriate connection on your serial device Model 1000R EIl A TIA 561 8 Position Interface Pin No Function DSR 2 DCD 3 DTR 4 SG 5 RD 6 TD CTS 8 RTS 3 3 OPERATING THE MODEL 1000R Once the Model 1000R is properly installed it should operate transparently as if it were a standard cable connection Operating power is derived from the EIA TIA 561 data and control signals there is no ON OFF switch APPENDIX A PATTON MODEL 1000R SPECI FI CATI ONS Transmission Format Asynchronous Data Rate Distance Surge Protection Control Signal Tr
2. between 19 and 26 AWG the higher number gauges may limit distance Standard dial up telephone circuits or leased circuits that run through signal equalization equipment are not acceptable For your convenience the Model 1000R is available with two different twisted pair interfaces an RJ 11 jack or an RJ 45 jack 3 1 1 TWISTED PAIR CONNECTION USING RJ 11 OR RJ 45 The RJ 11 and RJ 45 connectors on the Model 1000R s twisted pair interface are pre wired for a standard TELCO wiring environment see Figure 1 The table on the following page shows the signal pin relationships Blue 1 1 Blue 2 Orange 2 Yellow 3 Black 3 Green 4 Red 4 Red 5 Green 5 Black 6 Yellow 6 White 7 Brown 8 Slate Figure 1 AT amp T standard modular color codes RJ 1 SIGNAL RJ 45 SIGNAL en GND fines N C Das RCV ane acne GND peu XMT RCV F ES XMT de XMT CES RCV Bus XMT a GND a RCV F ES GND 8 N C When connecting two Model 1000Rs it is necessary to use a crossover cable The diagram below shows how a crossover cable should be constructed for an environment where both Model 1000Rs use a 4 wire RJ 11 connector Similar logic should be followed when using an RJ 45 connector or a combination of the two SIGNAL PIN COLOR COLOR PIN SIGNAL GNDt 1 Blue White 6 GNDt RCV 2 Yellow Red 4 XMT XMT 3 Green Black 5 RCV XMT 4 Red
3. USER MANUAL MODEL 1000R and 1000RS Async Short Range Modem for Modular EIA TIA 561 Systems at PE PATTON E Elecironics To ISO Part 07M1000R B SALES OFFICE J Doc 082011UB 301 975 1000 qu Revised 04 28 98 TECHNICAL SUPPORT en 801 975 1007 An 150 2001 http www patton com Certified Company 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 1000R components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 1000R generates and uses radio frequency energy and if not installed and used properly that is in strict acco
4. ansmit Line Transmit Mode Transmit Level Line Connection Power Supply Temperature Humidity Size 0 to 19 200 bps See table below Compliant with IEC 801 5 level 2 1kV Model 1000RS only DCD pin 2 and DSR pin 1 turn on when modem is powered up connected CTS pin 7 turns on immediately after the terminal raises RTS pin 8 4 wire unconditioned line Full duplex 4 wire 0 dBm RJ 11 RJ 45 No external power required uses ultra low power from data and control signals 32 to 140 F 95 non condensing 2 0 x 1 7 x 0 8 5 1 x 4 3 x 2 0 cm APPENDIX B PATTON MODEL 1000R CABLE RECOM M ENDATI ONS The Patton Model 1000R operates at frequencies of 20kHz or less and has been performance tested by Patton technicians using twisted pair cable with the following characteristics Wire Gauge Capacitance Resistance 19 AWG 9mm 83nf mi or 15 72 pf ft 0163 Ohms ft 22 AWG 6mm 83nf mi or 15 72 pf ft 0326 Ohms ft 24 AWG 5mm 83nf mi or 15 72 pf ft 05165 Ohms ft To gain optimum performance from the Model 1002 please keep the following guidelines in mind Always use twisted pair wire this is not an option e Use twisted pair wire with a capacitance of 20pf ft or less e Avoid twisted pair wire thinner than 26 AWG i e avoid higher AWG numbers than 26 e Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtainable Functi
5. onality should not be affected Environmental factors too numerous to mention can affect the maximum distances obtainable at a particular site Use maximum distance figures as a general guideline only Model 1000 Distance Table in Miles km Data Rate Wire Gauge bps 19 AWG 24 AWG 26 AWG 0 9 mm 0 5 mm 0 4 mm 19 200 6 2 9 9 3 7 5 9 1 2 1 9 9 600 7 5 12 0 4 9 7 8 2 5 4 0 4 800 8 7 13 9 5 6 9 0 3 7 5 9 2 400 11 8 18 9 8 0 12 8 4 9 7 8 27 2 1 200 17 0 27 2 11 8 18 9 8 0 12 8 APPENDIX B PATTON MODEL 1000R BLOCK DI AGRAM JOHA Tea PS en Henie Copyright 1998 Patton Electronics Company All Rights Reserved
6. r batteries Measuring only 2 0 x 1 7 x 8 5 1 x 4 3 x 2 0 cm the Model 1000R is housed in an ABS plastic case Connection to the EIA TIA 561 serial port is achieved using a modular RJ 45 jack Connection to the twisted pair interface is made through either an RJ 11 jack or an RJ 45 jack The serial device at the other end of the twisted pair cable can be connected to the Model 1000R using a Patton Model 1000 DB 25 1009 DB 9 1015 DB 15 or another Model 1000R The Model 1000S is a surge protected version of the Model 1002 that uses the latest in bi directional clamping transient suppressors to protect itself and connected equipment against harmful transient discharges For surge handling capability the Model 1000S is compliant with IEC 801 5 level 2 1kV 3 3 0 INSTALLATION The Model 1000R is easy to install This section tells you how to properly connect the Model 1000R to the twisted pair and EIA TIA 561 interfaces and how to operate the Model 1000R 3 1 CONNECTION TO THE TWISTED PAI R I NTERFACE The Model 1000R supports data only communication between an EIA TIA 561 device and another serial device There are two requirements for installation 1 These units work in pairs Therefore you must have one Model 1000R or compatible modem at each end of a two twisted pair cable 2 To function properly the Model 1000R needs two twisted pairs of metallic wire The pairs must be unconditioned dry metallic wire
7. rdance with the manufacturer s instructions may cause interference to radio and television reception The Model 1000R has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 1000R does cause interference to radio or television reception which can be determined by disconnecting the modem the user is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 1 2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive LVD of the Union European EU A Certificate of Compliance is available by contacting Patton Technical Support 1 3 SERVICE All warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This n
8. umber may be obtained from Patton Electronics Technical Service at telephone 301 975 1007 web address http www patton com email support patton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1000R Technical Service hours 8AM to 5PM EST Monday through Friday 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for One Year parts and labor If any questions or problems arise during installation or use of this product please do not hesitate to contact Patton Electronics Technical Support at 301 975 1007 2 1 FEATURES e Connects directly to the EIA TIA 561 device e Range to 17 miles 27 2 km e Data rates to 19 200 bps e No AC power or batteries required e Miniature size fits in tight locations e RJ 11 and RJ 45 twisted pair connection Silicon Avalanche Diode surge protection 1000RS only Compatible with Patton Models 1000 1009 and 1015 e Made in USA 2 2 DESCRI PTI ON The Patton Model 1000R Low Cost Short Range Modem allows an EIA TIA 561 device to communicate with RS 232 devices at distances up to 17 27 2 km miles over two unconditioned twisted pair Supporting asynchronous data rates to 19 2 Kbps the Model 1000R requires no AC power o