SETUP MANUAL

image

Contents

1. A 9 A 4 1 Cable Processing cola ede e d d e rt ee a A 9 A 4 2 SOIGGLING sd Hee dt el en i ae A 10 A 4 3 Shield Assemlbly e RU atit IE MS A 10 A 4 4 Method for Fabricating the Cable for Connection to OMRON A 11 A 4 5 Method for fabricating the cable for connection to A 13 AS List Of rre A 14 A 6 List of Options CPP A 19 Revision HISTOFV QUEE QUEM AWARAR CURE QUADRA 1 NB series Programmable Terminals Setup Manual V107 Read and Understand this Manual Please read and understand this manual before using the product Please consult your OMRON representative if you have any questions or comments Warranty and Limitations of Liability WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQ
2. 2 4 3 Settings for each Unit 2 5 FINS UDP Communication Connection 2 5 1 Connecting to Host Via Ethernet 2 5 2 Parameter Settings for FINS UDP at NB 2 5 3 Types and Settings of Ethernet Unit 2 5 4 Host Types and Settings of Ethernet IP Unit 2 5 5 Parameter Settings for FINS UDP at Host NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 1 Installing the NB Unit This section describes the methods used to mount the NB Unit onto an operation panel and connect the power supply 2 1 1 Installation environment When mounting the NB Unit onto the operation panel pay attention to the following precautions Always ensure that the personnel in charge confirm that installation inspection and maintenance were properly performed for the NB Unit Personnel in charge refers to individuals qualified and responsible for ensuring safety during machine design installation operation maintenance and disposal Ensure that installation and post installation checks are performed by personnel in charge who possess a thorough understanding of the machinery to be installed V Precautions for Correct Use
3. sw swa wor 0 System Setting Mode Calibrate Modo OFF Downloader Mode User Project Mode RESET MODE vi ETHERNET COM1 PLC RS232C PC RS232C SLAVE 1 q 1 Precautions for Safe Use Confirm the safety of the system before turning ON or OFF the power supply or pressing the reset button NB series Programmable Terminals Setup Manual V107 1 Part Names and Functions NB7W TWOOB NB7W TWO01B model Front view Power Indicator Display Back view 5 Sm dia mm RR Precautions for Safe Use Confirm the safety of the system before turning ON or OFF the power supply or pressing the reset button NB series Programmable Terminals Setup Manual V107 1 Part Names and Functions NB10W TWO1B model Front view SOWEN Hed 1 Power Indicator Display Back view 3 2 9 2 2 Precautions for Safe Use Confirm the safety of the system before turning ON or OFF the power supply or pressing the reset button NB series Programmable Terminals Setup Manual
4. 2 6 2 Network Device Setting Cour PLC Communication Setting PLC Communication Type WP Device No PLCO PLC Communication Time Out s 1 1982 168 250 2 Protocol Time Out 1 ms 1 Nico AC Gs E Protocol Time Out 2 ns 1 Port Num 9600 Max interval of word block pack 0 Max interval of bit block pack 16 Comm Protocol e Re Max word block package sire 1 it i Node ID ax bit block package size 16 Use Default Setting Note The settings of communication parameters should be the same as that of the actual PLC NB series Programmable Terminals Setup Manual V107 2 29 2 Installing the NB Unit and Connecting Peripheral Devices 2 30 Take the communication between single HMI and the PLC of Omron CJ2M CPU33 hereinafter abbreviated as PLCO as example DP Slave Configure the devices and set the communication parameters in the Construct Window then click Add in HMI Attribute HMI Network Device Setting to set parameters for HMI network interface communication HMI settings sample Communication nd Device Type Device No IP Address Port Number Mater Slave Node Protocol Number HMI HMIO 192 168 250 1 9600 Omron CJ Series M Master 1 Fins UDP PLC PLCO 192 168 250 2 9600 Omron CJ Series S Slave 2 Fins UDP Slave Please note that the IP address set here should be same as the actual IP address of PLC during the conf
5. A 7 A 3 1 Grounding and Shielding of the Cables A 7 A 4 Fabrication of the Connection Cable A 9 A 4 1 Cable 0 1 A 9 A 4 2 Soldering cz hl eit he RR RE eb ee ashe dk paced A 10 A 4 3 Shield Assembly A 10 A 4 4 Method for Fabricating the Cable for Connection to OMRON PLC A 11 A 4 5 Method for fabricating the cable for connection A 13 A 5 List of Models ip et ee ee ee a Ee A 14 A 6 List of Options eee bee ee eee A 19 NB series Programmable Terminals Setup Manual V107 A 1 Appendices A 1 Specifications A 1 1 A 1 2 A 2 General Specifications Items Specifications NB3Q NB5Q NB7W NB10W s TWOOB TWO1B TWOOB TWO1B TWOOB TWO1B TWO1B Rated power supply voltage DC24V 15 DC20 4 27 6V Power consumption 5W 9W 6W 10W 7W 11W 14W Ambient operating 0 C 50 C temperature Ambient storage temperature 20 C 60 C Ambient operating humidity 10 90 RH without condensation Ambient storage humidity 10 90 RH without condensation Operating environment No corrosive gases Noise Immunity Compliant with 61000 4 4 2KV Power cable Vibration resistance During operation 1
6. ON Switch Status Descriptions of Function corresponding model s ON Terminal resistance ON oe SW3 NB3Q Terminal resistance OFF SW3 NB10W Reserved SW4 NB3Q NB10W Reserved e Reset Switch When pressing the reset switch located on the back side of the PT the system will be rebooted NB series Programmable Terminals Setup Manual V107 1 9 1 Part Names and Functions NB series Programmable Terminals Setup Manual V107 Installing the NB Unit and Connecting Peripheral Devices This section describes the methods used to install the NB Unit and connect peripheral devices 2 1 Installing the NB 2 1 1 Installation 2 1 2 Installation onto the Operation 2 1 3 Connecting the Power Supply 2 1 4 Grounding 0 2 2 Start of NB Series 2 3 Connecting of NB series with PC 2 3 1 Connecting by RS 232C 2 3 2 Connecting by 2 3 3 Connecting by 2 4 Serial Communication Connection 2 4 1 Host Link Connection Method 2 4 2 Connecting more than one PLC
7. Do not install the product in any of the following locations Locations subject to rapid changes in temperature Locations subject to temperatures or humidity outside the range specified in the specifications Locations subject to condensation as the result of high humidity Locations subject to corrosive or flammable gases Locations subject to strong shock or vibration Locations outdoors subject to direct wind and rain Locations subject to strong ultraviolet light Locations subject to dust Locations subject to direct sunlight Locations subject to splashing oil or chemicals Take appropriate and sufficient countermeasures when the product is used in the following locations Locations subject to static electricity or other forms of noise Locations subject to strong electric field or magnetic field Locations close to power supply lines Locations subject to possible exposure to radioactivity Precautions for Safe Use When unpacking the NB Units and the peripheral devices check carefully for any external scratches or other damage Also shake the Units gently and check for any abnormal sound 2 2 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 1 2 Installation onto the Operation Panel Install the NB Unit by embedding it into the operation panel Use the panel mounting brackets and Phillips screwdriver for installation Proceed the installation following the
8. 2 You must use reinforced insulation or double insulation for the DC power supply and the DC power supply must have minimal voltage fluctuations and provide a stable output even if the power supply input is interrupted for 10 ms 3 The PTs conform to the standard EN 61131 2 but radiated emission characteristics 10m regulations may vary depending on the configuration of the control panel used other devices connected to the control panel wiring and other conditions You must therefore confirm that the overall machine or equipment complies with EC Directives 4 This is a Class A product Product for industry purpose It may cause radio interference in residential areas in which case the user may be required to take adequate measures to reduce interference NB series Programmable Terminals Setup Manual V107 17 Related Manuals The related manuals are as follows Devices and Software Manual Name Manual No NB series NB Series NB Designer Operation Manual V106 NB Series Setup Manual This manual V107 NB Series Host Connection Manual V108 NB Series Startup Guide V109 PLC SYSMAC CP Series CP1L CPU Unit Operation Manual W462 SYSMAC CP Series CP1H L CPU Unit Programming Manual W451 SYSMAC CP Series CP1H CPU Unit Operation Manual W450 SYSMAC CP Series CP1E CPU Unit Hardware USER S W479 Manual SYSMAC CP Series CP1E CPU Unit Software US
9. CPIH jom CP1L L NB series Programmable Terminals Setup Manual V107 2 13 2 Installing the NB Unit and Connecting Peripheral Devices When connecting to C Series CPU Units C200HX HG HE Z 10 2 CQM1H type CPU Units Connection Methods The connection methods for the CPU Units of different PLC models PLC Models RS 232C connection RS 422A connection C200HX HG HE Z Connect to the RS 232C port built in the Connect to the RS 422A port port A of CPU Unit the serial communication board Connect to the RS 232C port Ports A B of the serial communication board CPM1A Connect to the peripheral port with a Connect to the peripheral port with a dedicated RS 232C adaptor dedicated RS 422A adaptor CPM1 CIFO 1 CPM1 CIF11 type CPM2A Connect to the RS 232C port built in the Connect to the peripheral port with a CPU Unit dedicated RS 422A adaptor Connect to the peripheral port with a CPM1 CIF11 type dedicated RS 232C adaptor CPM1 CIFO1 CPM2C Connect to the RS 232C port built in the Connect to the peripheral port with a CPU Unit or the peripheral port with a dedicated conversion cable CPM2C dedicated conversion cable CPM2C CN111 type or CS1W CN114 type and CN111 type CS1W CN118 type and a RS 422A adaptor CPM1 CIF11 type CS1W CN114 type CPM2C CN1 11 2 111 type is a cable that type is a cable that divides the Unit port divides th
10. 24 10110 enne nenne nnne nnne nnns nennen nnns 2 5 2 1 4 Grounding Wing is ws serait i is cere Ce eie a o 2 6 2 2 Start of NB Serles 2 7 2 3 Connecting of NB series with PC 2 8 2 3 1 Connecting by 5 232 isi eine 2 8 2 3 2 Connecting Dy t t eo tefie ftoi ccrta ertet 2 9 2 3 3 Connecting by Ethernet ei ect ee e EXON t 2 10 2 4 Serial Communication 2 11 2 4 1 Host Link Connection 2 11 2 4 2 Connecting more than one 2 22 2 10 00 aiii edini didide 2 12 2 4 3 Settings for each Unit recede 2 13 2 5 FINS UDP Communication Connection cesses seen eese eene nnne nnn nnns 2 26 2 5 1 Connecting to Host Via Ethernet sssssssseeeeneeeee nennen neret renes 2 26 2 5 2 Parameter Settings for FINS UDP at NB 2 29 2 5 8 Host Types and Settings of Ethernet 2 31 2 5 4 Host Types and Settings of Ethernet IP Unit sssseeeeeeenenenneens 2 38 2 5 5 Parameter
11. side Ethernet Cable Communication conditions Select the corresponding download method by clicking the Download Way option in Tools menu of the NB Designer For details refer to 3 15 Download in the NB Designer Operation Manual 2 10 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 4 Serial Communication Connection 2 4 1 Host Link Connection Method Host Link is a connection method in which one PLC is connected to one NB Unit There are 2 kinds of connection methods RS 232C and RS 422A UOHeIIUNWIWOD Jenas t z The RS 232C connection method using serial ports COM1 COM2 This is the simplest and most feasible method NB Unit Hoet RS 232C cable maximum length 15m The following cables are recommended XW2Z 200T Cable length 2m by OMRON 27 500 Cable length 5m by OMRON pouije N uonoeuuo yu ISOH 1 The RS 422A connection method using the serial port COM2 With this method the communication distance can be extended to a maximum of 500m NB Unit RS 422A cable maximum length 500m The following cables are recommended NB RSEXT 2M Cable length 2m by OMRON Note please adopt 4 wire RS 422A connection and Host Link does not support 2 wire RS 485 connection Connectable Units at the host side When using OMRON PLCs the Units with built in Host Link function vary depending o
12. HMI Uploads the recipe data file rcp in HMI to the USB memory RCP HMI Downloads the recipe data file in USB memory to HMI The System Setting Mode screen of the NB7W TWO B is as follows 2000 01 01 00 03 47 NB7W TW01B SETUP Gateway Backlight Saver Time Startup Window No f USB SD NB series Programmable Terminals Setup Manual V107 3 3 3 System Setting Mode 3 4 The System Setting Mode screen of the NB7W TWOOB is as follows 2611 89 15 05 13 47 OMRON NB7W TWOOB SETUP Options Startup Window No Backlight Saver Time Min If you want to change the month click where the month is eg 09 and a digit input keyboard will pop up Input the month value and click the Enter button to confirm the change Startup Window Nc Backlight Saver Tin Brightness NB series Programmable Terminals Setup Manual V107 Calibrate Mode EINER This section describes the Calibrate Mode 4 1 Display Method of Calibrate Mode 4 2 4 2 Functions of Calibrate 4 2 4 3 On line Touch control Calibration Function 4 2 NB series Programmable Terminals Setup Manual V107 4 1 4 Calibrate Mode 4 1 Display Method of Calibrate Mode There are 2 methods for entering into Calibrate Mode 1 Set the DIP switches SW1 and SW2 on the back side respectively to OFF and
13. m 1 m 11 0000 000A 1 Communication speed 2 m 3 13 0000 Unit No 00 1 The communication speed should be set to the same value as that of the NB Unit Settings for the front side Switches Take CJ1W SCUA41 as an example CJ1W SCU41 5 041 RUN ERC SD ROI TER O O Display indicators Terminating resistance switch TERM Ez 65 o ie eD A Unit number setting switch Set a value between 0 and F that is not the same as these used by other Units in the system Two wire four wire switch WIRE RS 422A 4 four wire right position RS 485 2 two wire left position Port 1 RS 422A 485 Port 2 RS 232C NB series Programmable Terminals Setup Manual V107 2 25 2 Installing the NB Unit and Connecting Peripheral Devices 2 5 FINS UDP Communication Connection This section describes how to connect the PT with the Host through the FINS UDP protocol Note OMRON Ethernet UDP communication protocol both CJ CS Series and CP Series are FINS UDP protocol The difference between these two protocols is only in the address range of the channel 2 5 1 Connecting to Host Via Ethernet To connect to the network using Ethernet the network number node number and IP address must be set Use the NB Designer to set the settings The default IP address of HMI Unit is 192 168 250 1 Connecting PT Directly to the Host Connect the NB to the host using twisted pair cable NB Ho
14. Appendices Figure a Figure b CPU Rack CPU Rack RS 422A 485 RS 422A 485 Signal line Signal line NB series Programmable Terminals Setup Manual V107 Appendices 4 Fabrication of the Connection Cable Fabricate the connection cable following the procedures below A 4 1 Cable Processing Cut the cable to the required length Use a tool like a razor etc to cut off the ethylene peel of the cable Be care not to damage the shielding layer for grouping purpose Use a pair of scissors to snip off the shielding layer Bring out the core of each wire using a wire stripper Fold back the shielding layer 0 A Q Nou Wrap the folded part of the shielding layer with aluminum foil tape 2 i 5 2 Loo 40 RS 232C 5 25 RS 422A RS485 3 o 9 2 3 Oo 5 6 Unit mm Aluminum foil tape BuisseooJgd 2 L p v NB series Programmable Terminals Setup Manual V107 A 9 Appendices A A 2 Soldering 1 Sheathe each wire with a heat shrinkable tube 2 Place some standby soldering tin on each wire and each pin of the connector 3 Solder each wire and each pin of the connector Soldering iron Heat shrinkable tube Inside diameter 1 5 Length 10 4 Pull the heat shrinkable tubes back to the soldering parts heat them with a heat shrinking gun to make them shrink Heat shrinkable tube 4 3 Shield Assembly Assembl
15. C200HX Z models C200H LK201 LK202 V1 model Settings for the Switches For C200H LK201 V1 RS 232C Front side switches Each switch is a rotary switch Use a straight screwdriver set the switches as follows to display the numbers and symbols shown in the table UOHeIIUNWIWOD Jenas t z Set unit number SW1 SW2 SW1 and SW set to 0 e Command level parity check transmit code setting SW4 SWA set to 2 yun uoee 10 sDumes p z Communication speed setting SW3 4 800Bit s Set SWS to 4 9 600Bit s Set SWS to 5 19 200Bit s Set SW3 to 6 Back side switches Link Type switch Set SW3 to ON 1 to 1 CTS switch setting Default set to OV ON NB series Programmable Terminals Setup Manual V107 2 21 2 Installing the NB Unit and Connecting Peripheral Devices 2 22 For C200H LK202 V1 RS 422A Front side switches Each switch is a rotary switch Use a straight screwdriver set the switches as follows to display the numbers and symbols shown in the table Unit number settings SW1 SW2 Both of SW1 and SW are set to 0 e Settings of insrruction levels parity check and transmission codes SW4 SWA is set to 2 e Settings of communication speed SW3 4 800Bit s SW3 is set to 4 9 600Bit s SW3 is set to 5 19 200Bit s SW3 is set to 6 Back side switches e Settings of the terminal resistance selector switch Set it t
16. Net ID 7 bits Host ID 24 bits 31 15 0 bits Class B afol Net ID 14 bits Host ID 16 bits 31 7 0 bits Class C 1110 Net ID 21 bits Host ID 8 bits The number of networks and hosts that can be identified depends on the class used Class Network scope Number of hosts Class A Small 224 2 max 16 777 214 max Class B Medium 216 2 max 65 534 max Class C Large 28 2 max 254 max The IP address is a 32 bit value divided into four 8 bit fields Each octet is expressed as a decimal and is separated by a period Example 10000010 00111010 00010001 00100000 gt 130 58 17 32 ES Additional Information Set the same net ID for all nodes in the same network The net ID of the IP address is the value that identifies the Ethernet network IP network segment The net ID is not the same as the network address used for FINS communications The IP network segment is the logical network unit that is configured by the nodes that have the same net ID IP Address Allocation The IP addresses are allocated so that they are unique for each node in the network or between two or more networks If two or more nodes are allocated the same IP address the remote nodes with the same IP address will also malfunction IP Internet Protocol is a communications protocol that conforms to international standards Therefore to connect to the Internet always obtain IP addresses that have been allocated by a public organ
17. Press the Reset switch restart the NB Unit and then it enters into the Calibrate Mode 2 Place a Function Key component in the window and set its function to Touch Calibration Click this icon to start Calibrate Mode 4 2 Functions of Calibrate Mode Procedures to carry out Calibrate Mode Track and touch the displayed on the screen and you will hear a click Carry on with this until the disappear followed by a TP Adjust Success turning up on the screen Set both of the DIP switches SW1 and SW2 to OFF press the Reset switch again 4 3 On line Touch control Calibration Function Besides using the switches Touch control Calibration can also be achieved with a function key while the software is running thus sparing the time of equipment adjustment and the trouble of opening the control panel For details refer to 3 7 2 Function Key in the NB Designer Operation Manual 4 2 NB series Programmable Terminals Setup Manual V107 Appendices A 1 Specifications x3 uu Bee ee E 2 A 1 1 General Specifications A 2 A 1 2 Performance Specifications A 2 A 1 3 Communication Specifications 4 A 2 External Dimensions 5 A 3 RS 422A 485
18. address can be set from 01 to FE hex 1 to 254 decimal Setting range 01 to FE 1 to 254 decimal Set the upper digit using the left rotary switch and the lower digit using the right rotary switch The factory setting is 01 The Node ID of the dip switch here must be consistent with that of PLC in the Network Device Setting dialog box for the actual project created in the NB Designer Setting Local IP Addresses Set the local IP address with the CX Programmer or other Support Software For the setting procedure refer to the SYSMAC CS CJ series Ethernet IP Units Operation Manual Cat No W465 Ethernet Connectors This is the connector used to connect the twisted pair cable to the Ethernet e Electrical Characteristics Conforms to IEEE802 3 standards Connector Layout RJ45 8 pin modular connector conforms to ISO 8877 2 40 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices Connecting to a CJ series Ethernet IP Unit Note 1 Always turn OFF the power to the PLC before setting the rotary switches 2 Create I O tables for the CPU Unit when setting the unit number for the first time or changing settings CJ series EtherNet IP Unit CJ1W EIP21 Setting the Front Panel Switches dan SNl4 S Z Setting Unit Numbers Always set the unit numbers so that the unit numbers of other CPU Bus Units mounted to
19. 54 64 C200HW C200HX CPU44 64 65 85 Z C200HX CPU34 44 54 64 65 85 Z COMO02 04 05 06 V 1 CPM1 10 20CDR O CPM1 CIF01 CPM1A 10 20 30 40CDO O CPM1 CIF01 CPM24A 30 40 60CDLILI L1 CPM1 CIF01 When a peripheral port is connected cCPmM2c 10 20000000 0 1 CQM1H CPU11 21 51 61 2 CQM1H CPU51 61 CQM1H SCB41 CS Series CS1G CPU42 43 44 45 V1 CS1H CPU63 64 65 66 67 V1 CS1G CPU42 43 44 45 V1 CS1H CPU63 64 65 66 67 V1 CS1W SCU21 V1 CS1W SCB21 41 V1 CS1G CPU42H 43H 44H 45H CS1H CPU63H 64H 65H 66H 67H CS1G CPU42H 43H 44H 45H CS1H CPU63H 64H 65H 66H 67H CS1W SCU21 V1 CS1W SCB21 41 V1 CJ1 Series CJ1G CPU44 CPU45 CJ1G CPU44 CPU45 CJ1W SCU21 41 V1 CJ1G CPU42H 43H 44H 45H CJ1H CPU65H 66H 67H CJ1M CPU1 1 12 13 21 22 23 CJ1G CPU42H 43H 44H 45H CJ1H CPU65H 66H 67H CJ1M CPU1 1 12 13 21 22 23 CJ1W SCU21 41 V1 CJ1W SCU21 41 V1 CJ2 Series CJ2M CPU31 32 33 34 35 CJ2M CPU1 1 12 13 14 15 CP1W CIFO1 CJ2H CPU64 65 66 67 68 EIP 1 Connect using conversion cables CPM2C CN111 type or CS1W CN114 118 type the RS 232C adaptor CPM1 CIFO1 type or the RS 422A adaptor CPM1 CIF11 type 2 The CQM1H CPU11 model does not have the RS 232C port built in the CPU therefore it requires a peripheral port to be connected to a PT through a conversion cable CS1W CN118 type NB series Programmable Terminals Setup Manual V107
20. 67H CJ1M CPU11 12 13 21 22 23 CJ1W SCU31 41 V1 CJ2 Series CU2M CPU31 32 33 34 35 CP1W CIF11 CIF12 1 Connect using conversion cables CPM2C CN111 type or CS1W CN114 118 type the RS 232C adaptor CJ2M CPU1 1 12 13 14 15 CJ2H CPU64 65 66 67 68 EIP CPM1 CIFO1 type or the RS 422A adaptor CPM1 CIF11 type NB series Programmable Terminals Setup Manual V107 SI PON Jo 1611 S V Od uonoeuuoo 10 ejqeo Buneouqej 10 POAN G p v Appendices Units at the host side which can be connected using the Ethernet port of the NB Unit mU APE CPU Unit that can be connected through Options PLC Series with DH Ethernet adding Ethernet Communication required for communication function Stes Unit optional communication board connection CP Series CP1L L14 L20 M30 M40 M60 CP1W CIF41 CP1H X40 XA40 Y20 CP1W CIF41 CP1E N30 N40 N60 NA20 CP1W CIF41 CP1L EL20 EM30 EM40 CS Series CS1G CPU42 43 44 45 V1 CS1W ETN21 CS1H CPU63 64 65 66 67 V1 CS1W EIP21 CS1G CPU42H 43H 44H 45H CS1W ETN21 CS1H CPU63H 64H 65H 66H 67H CS1W EIP21 CS1H CPU63 64 65 66 67 V1 CS1W ETN21 CS1W EIP21 CS1H CPU63H 64H 65H 66H 67H CS1W ETN21 CS1W EIP21 CJ1 Series CJ1G CPU42H 43H 44H 45H CJ1W ETN21 CJ1H CPU65H CPU66H CJ1W EIP21 CJ1M CPU11 12 13 21 22 23 CJ1W ETN21 CJ1W EIP21 CJ1H CPU65H R 66H R 67H R CJ1W ETN21 CJ1H CPU65H CPU66H CJ1W EIP21 CJ2 Series CU2M CPU31 32 33 34 35
21. 9 NB10W TWO1B 14W lt NB5Q NB7W NB10W TWLILIB The reverse side of NB 2 DC24V Precautions for Safe Use Making the connection by using terminal screws crimping on a twisted pair cable with a crimping range of 12 26 AWG and only 6 5 mm of insulation peel of the cable needs to be peeled off Tighten the terminal screws at a torque of between 0 3 and 0 5 N m Make sure the screws are properly tightened NB series Programmable Terminals Setup Manual V107 2 5 2 Installing the NB Unit and Connecting Peripheral Devices 2 1 4 Grounding Wiring The NB Unit has a functional grounding terminal Arrange the wiring according to the following conditions 1 When a potential difference occurs between the NB Unit and the host arrange the grounding as illustrated If the distance is too long to realize a single point grounding do not ground the A of the NB Unit 7 2 When the NB Unit and noise source equipment such as motors and inverters etc are installed on the same panel do not ground the of the Unit NB Unit Single point grounding Precautions for Safe Use To prevent malfunctions caused by noise ground the Unit correctly 2 6 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 2 Start of NB Series Confirm the hardware are all correctly connected turn on the power supply and start the N
22. Unit to hold the fixators properly and tighten the screws firmly with the screwdriver NB5Q NB7W TWLILIB Special Information See below Icons are used to indicate precautions and additional information EN Precautions for Safe Use When operating on the operation panel make sure to keep metal particles from entering the Unit The mounting panel must be between 1 6 and 4 8 mm thick The NB Unit must be installed in a control panel For the sake of waterproof and dustproof all the fixators must be evenly tightened to a torque of 0 5 0 6 Nm If the tightening torque exceeds the specified value or the tightening is not even deformation of the front panel may occur Make sure that the operation panel is clean unbent and strong enough for the installation process M anu al name NB series Programmable Terminals Setup Manual V107 This illustration is provided only as a sample and may not literally appear in this manual Special Information Special information in this manual is classified as follows Precautions for Safe Use Precautions on what to do and what not to do to ensure using the product safely 14 Precautions for Correct Use Precautions on what to do and what not to do to ensure proper operation and performance amp Additional Information Additional information to increase understanding or make operation easier 4 NB series Programmable Terminals Setup Manual V107 Terminology
23. V107 1 Part Names and Functions 1 2 Part Specifications Touch Panel Input operation can be carried out by means of the touch panel By pressing the touch panel the Screens can be switched and the contact information can be transmitted to the host Do not use the input functions of the touch switch etc of the NB Unit in applications that involve human life in applications that may result in serious injury or for emergency stop switches Never press more than two points on the touch panel of the NB Unit at a time Otherwise it may activate a switch somewhere between the two points Precautions for Safe Use Do not press a touch switch with a force greater than 30 Do not accidentally press the touch panel when the backlight is not lit or when the display does not appear Make sure of the safety of the system before pressing the touch panel Confirm the safety of the system before pressing the touch panel Do not use hard or pointed objects to operate or scrub the screen or the surface of the screen may be damaged Signals from the touch switches may not be input if the switches are pressed consecutively at high speed Confirm each input before proceeding to the next one Deterioration over time can cause the touch points to move Calibrate the touch panel periodically Serial Port COM1 NB5Q NB7W NB10W TWLILIB Serial port COM1 is a 9 D type socket port This port support
24. and activate the settings in PLC system settings For CPM2A omron lt i sa PW2A o Set the communication condition setting switch to OFF downwards Carry out settings according to the using conditions of the peripheral port and built in RS 232C port When connecting the PT to the built in RS 232C port connect the device that needs to perform communications other than that within the standard setting range Set SW1 to OFF Set SW2 to ON When connecting the PT to the built in RS 232C port connect a programming console to the peripheral port PRO 0N Set SW1 to OFF Set SW2 to ON swi Ei rl 2 16 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices Setting methods for communication board switches For RS 422A For C200HX HG HE Z Switch 1 14 Side 4 wire RS 422A Switch 2 ON side terminal resistance ON Terminal resistance activated For 2 wire 4 wire switch WIRE 4 side 4 wire RS 422A Terminal resistance ON OFF switch TERM ON side terminal resistance ON Terminal resistance activated UONeIIUNWIWOD Jenas t z Serial Communication Board Lining Board Slot 1 Set the terminal resistance ON OFF switch to ON right side uoee 10 sbDumes p z 2 wire 4 wire Selector Switch RS 422A 4 4 wire right side RS
25. are defined as follows Functions Pins Signals I O ey RS 232C RS 485 RS 422A 1 SDB Sending data 2 SD PLC Sending data 3 RD PLC Receiving data 4 RS RTS Request to send 5 CS CTS Clear to send 6 RDB RS485B Receiving Send Receive data data 7 SDA y o Sending data 8 RDA RS485A Receiving Send Receive data data 9 SG Signal ground Pins 4 and 5 are not used thus not compliant with RS or CS functions Serial Port COM2 NB5Q NB7W NB10W TWLILIB Serial port COM2 is a 9 pin D type socket port This port supports RS 232C RS 485 RS 422A communication function The pins are defined as follows Pins Signals RS 232C Functions RS 422A 1 Sending data 2 SD O Sending data 3 RD Receiving data 4 Terminal R1 Terminal resistor 1 5 Terminal R2 Terminal resistor 2 6 RDB Send Receive Receiving data data 7 SDA Sending data 8 RDA Send Receive Receiving data data 9 SG Signal ground NB series Programmable Terminals Setup Manual V107 1 Part Names and Functions e USB HOST NBLILI TWO1B is equipped with USB HOST port which is USB A type port Through this port USB memory can be connected to perform uploading downloading project operation and storage of related
26. data And its pins are defined as follows din Pins 123 4 dh 1 2 3 Precautions for Safe Use Signals Functions Vbus USB 5V power supply output Max current 150mA D Data D Data GND USB power supply ground When connecting the equipment with the USB HOST connector make sure the supply equipment s current capacity is below 150mA before using it The DC 5V voltage output of the NB Unit is 5V 5 and the maximum current is 150mA e USB SLAVE USB SLAVE port is USB B type port which can connect the USB port on PC side to perform the uploading downloading and debugging of the programs for the product And its pins are defined as follows 3 2 4 1 Pins Signals Functions 1 Vbus USB 5V power supply output 2 D Data 3 D Data 4 GND USB power supply ground Ethernet Interface NBLILI TWO1B is equipped with Ethernet Interface which is adaptive RJ 45 type interface with the transmission rate of 10M 100M It can be connected with PC to perform the uploading and downloading of the programs and the system refreshing and can also be used to realize the communication with the controller supporting the Ethernet communication And its pins are defined as follows TOP Bottom Pins Signals Functions a T pe 1 TD pad data 2 TD Sending data i 3 RD Receiving data ZI 4 Not used 1 8 3 5 Not used 6 RD Receivin
27. make sure the panel is not dirty or warped and that itis strong enough to hold the Units Display Mode of NB Series touch panel NB Series touch panel has 2 display modes horizontal and vertical The display mode can be selected when dragging a HMI from the Graph element window into the Construct Window Graph element window Connector HMI 4 Display Mode NBTW TWO1B NBTW TWOOB NBSQ TWO1B NBSQ THOOB HMI Display Mode JF Menu Task Bar Menu Task Bar T P Horizontal display Vertical display 2 4 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 1 3 Connecting the Power Supply Precautions for Safe Use Do not connect an AC power supply to the DC power terminals Use a DC power with a slight voltage fluctuation and that will provide a stable output even if the input is momentarily interrupted for 10 ms Rated Power Supply Voltage DC 24 V Allowable range DC 20 4 27 6 V eui 1 2 Power Supply The connectable power supply specifications are as follows figure out a suitable power supply specification so as to satisfy the requirement for power supply capacity Models Rated Voltage Allowable Voltage Range Power NB3Q TWOOB DC20 4V to 27 6V 5W a NB3Q TW01B 9W S NB5Q TW00B ew 2 NB5Q TWO1B 10W a NB7W TWOOB 7W 2 NB7W TWO1B 11W
28. procedures CP1L EL EM SYSMAC CP Series CP1L EL EM CPU Unit Operation Manual Cat No W516 jo sBumes pue 1S0H 6 5 2 Ethernet Connector CP1L ETN21 This is the connector used to connect the twisted pair cable to the Ethernet e Electrical Characteristics Conform to the IEEE 802 3 standard Connector Layout RJ45 8 pin modular connector conforms to 1508877 NB series Programmable Terminals Setup Manual V107 2 37 2 Installing the NB Unit and Connecting Peripheral Devices 2 5 4 Host Types and Settings of Ethernet IP Unit NB series PTs can communicate with CS CJ series Ethernet IP Units and CJ2H CPULILI EIP CJ2M Units that are used for Ethernet IP communications vary according to the type and series of OMRON PLC used When connecting an Ethernet IP Unit check the series and type of the PLC that it will be connected to and the model of the Unit that is mounted to the PLC NB series PTs and the following Controllers can be connected with Ethernet IP units Series name Using the built in board CS Series Using an Ethernet Unit Ethernet Unit CS1G H CPULILI V1 CS1W EIP21 CS1G H CPULILIH CS1D CPULILIH CJ Series CJ1G H CPULILIH CJ1W EIP21 CJ1M CPULIDI ETN CJ2H CPULILI EIP CJ2M CPUSLI CJ2H CPULILI EIP CJ1W EIP21 CJ2M CPULILI CP Series CP1H CJ1W EIP21 Note Ethernet IP Unit Unit version 2 1 or later the CJ2H CPULILI
29. procedures below 1 Panel cutout with dimensions is shown below Fit the NB Unit into the panel from the front side eui 1 2 Opening dimensions us Models Opening Dimension W XH mm NB3Q TWOOB TWO1B 119 0 0 5 0 x 93 0 0 5 0 NB5Q TWOOB TWO1B 172 4 0 5 0 131 0 0 5 0 NB7W TWOOB TWO1B 191 0 0 5 0 x 137 0 0 5 0 NB10W TWO1B 258 0 0 5 0 x 200 0 0 5 0 joueg eui 5 z L c 2 As follows insert the panel mounting brackets at the locations indicated by red box around the back of the NB Unit Insert the hooks of positioners into the square holes on the Unit to hold the fixators properly and tighten the screws firmly with the screwdriver NB5Q NB7W TWLILIB NB series Programmable Terminals Setup Manual V107 2 3 2 Installing the NB Unit and Connecting Peripheral Devices The insert positions on the body of NB3Q TWLILIB NB10W TWO1B same fixing method as above NB3Q TWLILIB NB10W TWLILIB Precautions for Safe Use Do not let metal particles enter the Units when preparing the panel The mounting panel must be between 1 6 and 4 8 mm thick Tighten the Mounting Brackets evenly to a torque of between 0 5 and 0 6 N m to maintain water and dust resistance If the tightening torque exceeds the specified value or the tightening is not even deformation of the front panel may occur What is more
30. sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given NB series Programmable Terminals Setup Manual V107 Manual Structure Page Structure and Icons The following page structure and icons are used in this manual 2 Installing the NB Unit and Connecting Peripheral Devices Level 1 heading Level 2 heading Level 3 heading 2 1 2 Installation onto the Operation Panel Level 3 heading Install the NB Unit by embedding it into the operation panel Gives the current headings Use the metal kit and tool a crosshead screwdriver supplied with the Unit for installation Proceed the installation following the procedures below Step In a p roced u re 1 Panel cutout with dimensions is shown below Fit the NB Unit into the panel from the front side HUN L Z Indicates a step in a procedure Page tab Gives the number of the section Opening dimensions Models Opening Dimension mm NB3Q TWOOB TWO1B 119 0 0 5 0 93 0 0 5 0 NB5Q TWOOB TWO1B 172 4 0 5 0 131 0 0 5 0 NB7W TWOOB TWO1B 191 0 0 5 0 137 0 0 5 0 NB10W TWO1B 258 0 0 5 0 200 0 0 5 0 loued uoneiedo eu uonerersu 2 1 2 2 As follows insert panel fixators at the locations indicated by red box around the back of the NB Unit Insert the hooks of positioners into the square holes on the
31. 0 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 1 The RS 232C port of the Communication Board 2 The RS 232C port of the Serial Communication Board 3 OU is the set value of the communication speed Set the communication speed to the same value as that of the NB Unit 4 Standard settings of the Communication conditions are as follows Start bit 1 bit Data bit 7 bit Stop bit 2 bit parity check even uon2euuo jenas t z For RS 422A Host Model Channel No Write Value Setting Port A of DM6555 0001 Use Host Link C200HX HG HE 556 OSLILI 3 Communication conditions are standard settings 4 d DM6558 0000 Unit No 00 Port 2 of DM6550 0001 Use Host Link CQM1H 2 DM6551 O3LILI 3 Communication conditions are standard settings 4 DM6553 0000 Unit No 00 1 The RS 422A port of the Communication Board 2 The RS 422A port of the Serial Communication Board 8 OU is the set value of the communication speed Set the communication speed to the same value as that of the NB Unit 4 Standard settings of the Communication conditions are as follows Start bit 1 bit Data bit 7 bit Stop bit 2 bit parity check even uoee 10 sbDumes p z For operations on PLC System Settings Area refer to the manual of the PLC employed Connection methods for CPM2C CPM2C only has a conn
32. 0 POUN NB series Programmable Terminals Setup Manual V107 11 Appendices i COM2 The cable for connecting the NB5Q NB7W NB10W Unit serial port COM2 to OMRON PLC RS 232C RS232 port at the COM female NB Unit side OMRON PLC side OMRON PLC side at the NB Unit side Signal Name Shielded Cable Pin _ Signal female Connector EA Shield RD RXD 6 8 9 The cable for connecting the NB5Q NB7W NB10W Unit serial port COM2 to OMRON PLC RS 422A COM2 female NB Unit side OMRON PLC side at the NB Unit side 1 6 gt O d 6 8 Y sa 9 Shielded Cable 5 9 Connector Note If the RS 485 connection is adopted all needed to do is to connect the No 6 and No 8 pins and the shielded cable to the corresponding pins on the PLC side 12 NB series Programmable Terminals Setup Manual V107 Appendices A 4 5 Method for fabricating the cable for connection to PC When fabricating the cable for connecting with NB Designer refer to the following methods Depending on the type of the RS 232C connector compatible with PCs according to DOS V deploy the wiring as shown below i 25 pin Connector COM female NB Unit side DB25 Serial Port at the PC side RS232 DB25 male at the NB Unit side Signal Name Pin No Shielded Cable Pin No Sign
33. 0 to 57Hz with a 0 075mm amplitude 57 to 150Hz 9 8m s for 30 min each in X Y and Z directions Shock resistance During operation 147m s for 3 times each in X Y and Z directions with each time lasting for 11 ms Dimensions WxHxD mm 129 8x103 8x52 8 184 0x142 0x46 0 202 0x148 0x46 0 268 8x210 8x54 0 Panel opening dimension WxH mm 119 0x93 0 172 4x131 0 191 0x137 0 258 0x200 0 Panel thickness range 1 6 4 8 mm Weight 310g 315g 620g 625g 710g 715g 1545g Degree of protection Front operation part IP65 Dust proof and drip proof only from the front of the panel Battery life 5 years at 25 Applicable standards EC Directives KC cULus508 Performance Specifications Display specifications Specifications Items NB3Q NB5Q NB7W NB10W 00 TWO1B TWO1B Display Display device 3 5 TFT LCD 5 6 TFT LCD 7 TFT LCD 10 1 TFT LCD panel Resolution 320x240 320x234 800x480 800x480 Display color 65536 colors Valid display area 71x53 113x85 154x85 221x133 WxH mm Backlight Life 50 000 hours Typ of operating time at the normal temperature 25 with 40 brightness Front side LED ON power connected OFF power disconnected NB series Programmable Terminals Setup Manual V107 Appendices Operation part specifications Specifications Items NB3Q NB5Q NB7W NB10W TWOOB TWO1B TWOOB TWO1B TWOOB TWO1B TWO1B Touch panel T
34. 00000 FFFFFFOO The subnet mask must have a value that is common to all nodes on the same sub network Setting the subnet mask is not required if sub networks are not used The system recognizes subnet masks without a subnet ID field i e subnet masks with net ID and host ID fields only The methods for setting each Unit are described next H CS series PLCs Note 1 Always turn OFF the power to the PLC before setting the rotary switches 2 Create I O tables for the CPU Unit when setting the unit number for the first time or changing settings jo sbBumes pue sed ISOH 6 5 2 CS series Ethernet Units CS1W ETN21 Setting the Front Panel Switches Setting Unit Numbers Always set the unit numbers so that the unit numbers of other CPU Bus Units mounted to the CPU Unit are all unique Use a small screwdriver to set the rotary switches being careful not to damage them The factory setting is 0 Setting range OtoF NB series Programmable Terminals Setup Manual V107 2 33 2 Installing the NB Unit and Connecting Peripheral Devices Setting Node Numbers Setting range 01 to FE 1 to 254 decimal Set the upper digit using the left rotary switch and the lower digit using the right rotary switch The factory setting is 01 The Node ID of the dip switch here must be consistent with that of PLC in the Network Device Setting dialog box for the actual project created in the NB Designer Setti
35. 422A RS 485 communication cable RS232C Connector use short wire to connect 4 and 5 pay attention to wiring do not short circuit with other pins except PIN4 and PIN5 when connection finished please assembled well RS232C Connector When using NB3Q TWLILIB Unit turn the DIP switch SW3 of the unit to ON By default RS 422A RS 485 communication cable do not connect terminal resistance e USB Memory It can be connected to the USB HOST port on the back of PT to perform the uploading downloading project operation and storage of related data Recommended Purchasing Model FZ MEM2G FZ MEM8G Descriptions USB disk with 2GB capacity manufactured by OMRON USB disk with 8GB capacity manufactured by OMRON NB series Programmable Terminals Setup Manual V107 Revision History A manual revision code appears as a suffix to the Catalog number on the front cover of the manual Revision code Cat No V107 E1 L October 2011 Revision code Revised content Original production February 2012 Adding optional RS 422A RS485 communication cable in Appendix 6 Correcting the descriptions of the battery April 2012 Adding descriptions and new functions of NB5Q NB7W TWO01B model NB series Programmable Terminals Setup Manual V107 August 2012 Adding descriptions and new functions of NB3Q TWOOB TWO1B and NB10W TWO1B models Revision 1 Revision 2 NB series Programmable Termin
36. 485 z 2 wire left side Settings for the communication adaptor switch For RS 232C adaptor CPM1 CIFO1 type Set the mode setting switch to HOST Up side For RS 422A adaptor CPM1 CIF11 type Set the terminal resistance switch to ON Up side NB series Programmable Terminals Setup Manual V107 2 17 2 Installing the NB Unit and Connecting Peripheral Devices When connecting to CS Series CPU Units For C81G H CPULILI V1 types and CS1G H CPULILIH types Connection Methods Connect to the RS 232C port built in the CPU Unit or the RS 232C port of the communication board When connecting to the peripheral port a connection cable dedicated for the peripheral port is needed CS1W CN118 type Only RS 232C can be used for connection PLC System Settings Area When connecting to CS Series CPU Unit refer to the following table and set the communication conditions as follows in PLC System Settings based on the communication port in use Connection Methods Channel No Write Value Setting Use the RS 232C port built 160 8000 Use Host Link CS1G H CS1G H H 161 0000 000A 1 Communication speed 163 0000 Unit No 00 Use the peripheral port of 144 8000 Use Host Link CS1G H CS1G H H 145 0000 000A 1 Communication speed 147 0000 Unit No 00 1 The communication speed should be set to the same value as that of the NB Unit PLC System Settings can be directly set with a peri
37. 8877 NB series Programmable Terminals Setup Manual V107 2 41 2 Installing the NB Unit and Connecting Peripheral Devices 2 5 5 Parameter Settings for FINS UDP at Host Side Because the port number of NB is dynamic the user doesn t need to set it during the communications through the FINS UDP protocol But user needs to set the UDP parameters at the Host side of OMRON PLC in the CX Programmer referring to the following limitations Take the settings of CJ1W ETN21 as example CJIW ETN21 ETN21Mode Edit Parameters Setting FINS TCP DNS 9 POP Mail Address Mail Send Mail Receive Clock amp Broadcast FINS UDP Port FINS TCP Port TCP IP keep alive 6 Default 960 Default 960 10 nin 0 default C User defined C User define b b Performance of socket service High Speec Conversion Baud Rate FINS UDP Option Destination IP is changed dynamic Auto amic 6 Auto C 10 Sub net Mask 9559 29 ombine Enable CIDE C IP address tab C ETNII compatible mode IP Address Table IP Router Table FTP Login Password Port No o 0 ss zaf 2 Unit to PO rensferPC to Unit Conpere Set Defaults The limitations are as follows 1 Do not check the Auto Static option in the Conversion check box 2 Do not check the Destination IP is Not changed dyn in the FINS UDP Option check box 3 Only the Destination IP is changed dynamic can be ch
38. Appendices Units at the host side which can be connected using the serial port of the NB Unit in the RS 422A mode through Host Link CPU Unit with built in Host CPU Unit that can be connected Options required for PLC Series 5 through adding Host Link Link function 2 PAURA connection Units communication boards CP Series CP1L L14 L20 M30 M40 M60 CP1L L14 L20 M30 M40 M60 CP1W CIF1 1 CIF12 CP1H X40 XA40 Y20 CP1H X40 XA40 Y20 CP1W CIF11 CIF12 CP1E N30 N40 N60 NA20 CP1E N30 N40 N60 NA20 CP1W CIF11 CIF12 CP1L EL20 EM30 EM40 CP1W CIF11 CIF12 C Series C200HE CPU1 1 32 42 C200H LK202 V 1 C200HE CPU1 1 32 42 2 C200HG CPU33 43 53 63 C200HG CPU33 43 53 63 Z C200HX CPU34 44 54 64 C200HX CPU34 44 54 64 65 85 Z C200HE CPU32 42 C200HW COMO3 06 V 1 C200HE CPU32 42 Z C200HG CPU33 43 53 63 C200HW COMO3 06 V 1 C200HG CPU33 43 53 63 Z C200HX CPU34 44 54 64 C200HW COMO3 06 V 1 C200HX CPU34 44 54 64 65 85 Z CPM1 10 20CDR O CPM1 CIF1 1 CPM14A 10 20 30 40CDLI L1 1 11 CPM2A 30 40 60CDLILI E 1 11 When peripheral port is connected CPM2cC 10 20000000 O0 1 CQM1H CPU51 61 CQM1H SCB41 CS Series CS1G CPU42 43 44 45 V1 CS1W SCB41 V1 CS1H CPU63 64 65 66 67 V1 CS1W SCU31 V1 CS1G CPU42H 43H 44H 45H CS1W SCB41 V1 CS1H CPU63H 64H 65H 66H 67H CS1W SCU31 V1 CJ1 Series CJ1G CPU44 45 CJ1W SCU31 41 V1 CJ1G CPU42H 43H 44H 45H CJ1W SCU31 41 V1 CJ1H CPU65H 66H
39. B Series This part describes the operations of the NB Series when it starts When starting the NB Unit for the first time 1 Confirm that the DIP switches SW1 and SW2 on the back side are both ON 2 Turn on the power supply of the NB Unit and with the POWER LED on the front side turning green the NB Unit starts entering into the System Setting Mode 3 Through the System Setup screen the system time starting window No screen saving time buzzer and the screen brightness can be set When the setup is finished turn OFF the power supply turn OFF both of the DIP switches SW1 and SW2 and then switch on the power supply again JO 11815 Z Z When starting the NB Unit after downloading the screen data to it 1 Confirm that the DIP switches SW1 and SW2 on the back side are both OFF 2 Turn on the power supply of the NB Unit and with the POWER LED on the front side turning green the NB Unit starts 3 The starting screen of the screen data downloaded to the NB Unit will be shown p L z Entering into Calibrate Mode 1 Confirm that the DIP switches SW1 and SW2 on the back side are respectively OFF and ON 2 Turn on the power supply of the NB Unit and with the POWER LED on the front side turning green the NB Unit starts 3 When the user touches the panel a symbol will pop up on the screen with which the touch control precision level can be calibr
40. CJ2M CPU11 12 13 14 15 CJ1W ETN21 CJ1W EIP21 CJ2H CPU64 65 66 67 68 EIP Software related to the NB Unit Name Version Release Time Descriptions NB Designer V1 0X February 2012 HMI with model number of NB5Q TWOOB and NB7W TWOOB supported V1 1X June 2012 HMI with model number of NB5Q TW01B and NB7W TWO01B added V1 2X August 2012 HMI with model number added Related connecting objects Cable with connectors NB Unit lt gt PLC of NB3Q TWOOB TWO1B and NB10W TWO1B are Remarks OS Windows XP SP1 or higher Windows Vista Windows 7 32 64 bit The NB Designer incorporates a transmission program and a standard system program specified for the NB Series Units For download the application programs please access your local Omron website If local site cannot be found please access Omron global site http www ia omron com at first and select the area where you Models Cable Length Object Unit Communications methods Specifications XW2Z 200T 2m Units with 9 pin Host Link 9 pin lt 9 XW2Z 500T connectors by RS 232C OMRON NB RSEXT 2M 2m RS 422 485 Host Link 9 pin 5 wire Communication RS 422 485 Units by PLC manufacturers NB series Programmable Terminals Setup Manual V107 Appendices A 6 List of Options e Anti reflection Film It adheres to the display preventing reflection and also dirt from sticking to the display It is colorless a
41. Cat No V107 E1 04 NB series NB3Q TWOOB NB5Q TWOOB NB7W TWOOB NB10W TW01B Programmable Terminals SETUP MANUAL OMRON 2012 rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of OMRON No patent liability is assumed with respect to the use of the information contained herein Moreover because OMRON is con stantly striving to improve its high quality products the information contained in this manual is subject to change without notice Every precaution has been taken in the preparation of this manual Nevertheless OMRON assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in this publication NB series 5 NB7W TWLILIB NB10W TWOIB Programmable Terminals Setup Manual Hevised August 2012 Introduction Thank you for purchasing an NB series Programmable Terminal NB Series Programmable Terminals PTs are designed to handle information generated in FA production sites Be sure to understand the functions and performances etc thoroughly before using PT correctly Intended Audience This manual is intended for the following personnel who must also have knowl
42. EIP and 2 CPU Units have built in Ethernet connector For details on the hosts that can be connected to NB series PTs via the Ethernet IP refer to A 5 List of Models Refer to the following manual for host parameter settings SYSMAC CS CJ series Ethernet IP Units Operation Manual Cat No W465 SYSMAC CJ2 CPU Units Operation Manual Cat No W472 For the limitations to the Host parameters setting refer to 2 5 5 Parameter Settings for FINS UDP at Host Side i Connecting to a CJ series CPU Unit Note 1 Always turn OFF the power to the PLC before setting the rotary switches 2 Create I O tables for the CPU Unit when setting the unit number for the first time or changing settings CJ series CPU Unit Built in EtherNet IP Port CJ2H CPULIDI EIP CJ2M CPU30 Setting Local IP Addresses Set the local IP address with the CX Programmer or other Support Software Refer to the SYSMAC CS CJ Series Ethernet IP Units Operation Manual Cat No W465 for details on setting methods 2 38 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices Setting the Front Panel Switches Setting the Unit Numbers Set a unique unit number for the CJ2 CPU Unit built in Ethernet IP port The same unit number cannot be used by any other CPU Bus Unit connected to the CJ2 CPU Unit Use a small screwdriver to make the setting and be sure not to damage the ro
43. ER S W480 Manual SYSMAC C200HX HG HE E ZE Installation Guide W302 SYSMAC C200HX HG HE Operation Manual W303 SYSMAC C200HX HG HE ZE Operation Manual W322 SYSMAC 1 Operation Manual W317 SYSMAC CPM2A Operation Manual W352 SYSMAC CPM1 CPM1A CPM2A CPM2C SRM1 V2 W353 Programming Manual SYSMAC CPM2C Operation Manual W356 SYSMAC CS1 Series CS1G H Operation Manual W339 SYSMAC CS CJ Series Serial Communications Boards and W336 Serial Communications Units Operation Manual SYSMAC CJ Series CJ1G H H CJ1M CJ1G Operation W393 Manual SYSMAC CS CJ Series Programming Manual W394 SYSMAC CS CJ Series INSTRUCTIONS Reference Manual W340 SYSMAC CS CJ Series Programming Consoles Operation W341 Manual SYSMAC CS CJ Series Communications Commands W342 Reference Manual SYSMAC CJ Series CJ2 CPU Unit Hardware USER S Manual W472 SYSMAC CJ Series CJ2 CPU Unit Software USER S Manual W473 SYSMAC CS CJ Series CS1W CJ1W ETN21 100Base TX W420 Ethernet Units Operation Manual Construction of Networks SYSMAC CS CJ Series CS1W CJ1W ETN21 100Base TX W421 Ethernet Units Operation Manual Construction of Applications SYSMAC CS CJ Series CS1W CJ1W EIP21 100Base TX W465 EtherNet IP Units Operation Manual SYSMAC CP Series CP1L EL EM CPU Unit Operation Manual W516 External Tool CX Programmer Ver 9 L Operation Manual W446 18 NB series Programmable Terminals Setup Manual V107 Part Names and Functions This section describes the nam
44. Jenas t z PLC System Settings Area for RS 232C When connecting to the CJ Series CPU Unit refer to the following table and set the communication conditions as follows in PLC System Settings based on the communication port in use Connection Methods Channel No Write Value Setting Use the RS 232C port built 160 8000 Use Host Link t CJ1G CPULTH type 161 0000 000A Communication speed CJ1G H CPULILH types a CJ1M CPULILI types 163 0000 Unit No 00 o Use the peripheral port of 144 8000 Use Host Link Sg CJ1G CPULTH type 145 0000 000A 1 Communication speed 8 1 types 5 1 147 0000 00 1 The communication speed should be set to the same value as that of the NB Unit PLC System Settings can be directly set with a peripheral tool Programming console or it can be set by transmitting the PLC System Settings set up by a peripheral tool CX Programmer to the CPU Unit For details about the PLC System Settings refer to SYSMAC CJ Series Operation Manual W393 Settings for the front side Switches Set the DIP switches 4 or 5 as follows according to the NB Series port connected DIP Switch in the battery jar When connecting a NB Series Unit to a peripheral port set SW4 to ON communications carried out according to the PLC system settings When connecting a NB Series Unit to a RS 232C port set S
45. RS 422A 485 2 ports CS series CS1G H CS1G H H CJ1W SCU21 RS 232C 2 ports CJ1 series CJ1G H H CJ1M CJ1W SCU31 RS 422A 2 ports CJ1 series CJ1G H H CJ1M CJ1W SCU41 RS 232C 1 port CJ1 series CJ1G H H CJ1M RS 422A 1 port Ethernet Communication Unit Models Specifications Applicable PLCs CS1W ETN21 100Base TX 10Base T CS series CS1G H CS1G H H CS1W EIP21 100Base TX 10Base T CS series CS1G H CS1G H H CJ1W ETN21 100Base TX 10Base T CJ1 series CJ1G H H CJ1M CJ1W EIP21 100Base TX 10Base T CJ1 series CJ1G H H CJ1M CJ1W CIF41 100Base TX 10Base T CP1H CP1L CP1E NB series Programmable Terminals Setup Manual V107 PLC Series Connectable to NB Series through Host Link Appendices PLC Series Specifications CP Series Connecting through the RS 232C optional communication board CP1W CIF01 with a RS 232C cable C200HE HG HX Series With a connector for RS 232C connection switch 9 pin type CQM1H Series With a connector for RS 232C connection 9 pin type CPM1A Series Connecting through the RS 232C adaptor CP1W CIFO01 with a RS 232C cable 2 Series With a connector for RS 232C connection 9 pin type CPM2C Series Connect to the branched RS 232C connector through a conversion cable CPM2C CN111 type CS Series With a connector for RS 232C connection 9 pin type CJ1 CJ2 Series With a connector for RS 232C connection 9 pin type PLC Ser
46. S1W ETN21 This is the connector used to connect the twisted pair cable to the Ethernet e Electrical characteristics Conforms to IEEE802 3 standards e Connector structure RJ45 8 pin modular connector conforms to 1508877 Connector Pin Signal name Abbreviation Signal direction 1 Send data TD Output 2 Send data TD Output 3 Receive data RD Input 4 Not used 5 Not used 6 Receive data RD Input 7 Not used 8 Not used CJ series PLCs Note 1 Always turn OFF the power to the PLC before setting the rotary switches 2 Create I O tables for the CPU Unit when setting the unit number for the first time or changing settings CJ series Ethernet Units CJ1W ETN21 Setting the Front Panel Switches Setting Unit Numbers Always set the unit numbers so that the unit numbers of other CPU Bus Units mounted to the same CPU Unit are all unique Use a small screwdriver to set the rotary switches being careful not to damage them The factory setting is O Setting range Oto F 2 35 NB series Programmable Terminals Setup Manual V107 5 S Z jo pue sed ISO 6 5 2 2 Installing the NB Unit and Connecting Peripheral Devices Setting Node Numbers Set the node numbers as hexadecimal values with the node number setting switch Always set the node numbers so that othe
47. Settings for FINS UDP at Host 2 42 Sec 3 System Setting OUI 3 1 Display Method of System Setting Mode 3 2 3 2 Functions of System Setting 3 3 NB series Programmable Terminals Setup Manual V107 7 4 4 1 4 2 4 3 Calibrate 2 Display Method of Calibrate 4 2 Functions of Calibrate Mode 4 2 On line Touch control Calibration 4 2 Sec A teehee Lu egre ze Ic A 2 A 1 1 General Specifications etii Per ed ado et cep eco Seve det A 2 A 1 2 Performance Specifications ence ete A 2 A 1 3 Communication Specifications eeesssssessssseseeeseeeneenne enne nennen 4 2 External Dimensions 5 3 RS 422A 485 Connections erc eee rire a irte rua een A 7 A 3 1 Grounding and Shielding of the Cables essere A 7 A 4 Fabrication of the Connection
48. The following terminology is used in this manual Terms Descriptions NB Unit Indicates the main Unit of the products in the OMRON NB Series of Programmable Terminal NB Series Indicates products in the OMRON NBLILI Series of Programmable Terminal In this manual unless otherwise specified NBLILI Series is taken as the subject concerned PLC Indicates a Programmable Controller CP Series Indicates the following products in the OMRON CP Series of Programmable Controllers CP1H CP1L CP1E CS CJ Series C Series Indicates the following products the OMRON CS CJ Series of Programmable Controllers CS1G CS1H CS1G H CS1H H CJ1G CJ1M CJ2M CJ2H Indicates the following products in the OMRON C Series of Programmable Controllers C200HX Z C200HG Z C200HE Z COM1 CPM1A 2 CPM2C Serial Communication Unit Indicates a Serial Communication Unit for an OMRON SYSMAC CS CJ Series PLC Serial Communication Board Indicates a Serial Communication Board for an OMRON SYSMAC CS CJ Series PLC Communication Board Indicates a Communication Board for an OMRON C200HX HG HE Z PLC CPU Unit Indicates a CPU Unit in the OMRON CP CS CJ or SYSMAC C Series of Programmable Controllers NB Designer Indicates the OMRON NB Designer Host Indicates the PLC and other units functioning as the control devices for NB Series Units PT Indicates an OMRON Programmable Termina
49. UIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR NB series Programmable Terminals Setup Manual V107 9 Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products At the customer s request OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine System or other application or use The follo
50. W5 to OFF communications carried out according to the PLC system settings Peripheral Port Used for connecting programming consoles ect RS 232C Port Used for connecting devices other than programming consoles NB series Programmable Terminals Setup Manual V107 2 19 2 Installing the NB Unit and Connecting Peripheral Devices When connecting to CJ2 Series CPU Units For CJ2M CPUSLI type CJ2M CPU1L1 type and CJ2H CPUGLI EIP type Connection Methods Connect to the RS 232C port built in the CPU Unit or the RS 232C port of the communication board PLC System Settings Area for RS 232C Carry out setting by transmitting the PLC System Settings set up by a peripheral tool CX Programmer to the CPU Unit On the Serial Port options page of PLC System Settings set the connection mode to Host Link 7 Data Bits 2 Stop Bits Even And set the communication speed to the same as that of the NB Unit For details about the PLC System Settings refer to SYSMAC CJ2 Series Software User s Manual W473 Settings for the front side Switches Set the DIP switch 5 of the CPU Unit as follows according to the NB Series port connected Turn DIP SW5 OFF for serial communications 2 20 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices i When connecting to Host Link Units of C Series Base mounted type for C200HE Z C200HG Z
51. air cable to the Ethernet Electrical Characteristics Conforms to IEEE802 3 standards Connector Layout RJ45 8 pin modular connector conforms to ISO 8877 1 Connector Pin Signal name Abbreviation Signal direction 1 Send data TD Output 2 Send data TD Output 3 Receive data RD Input 8 4 Not used 5 Not used 6 Receive data RD Input 7 Not used 8 Not used NB series Programmable Terminals Setup Manual V107 2 39 2 Installing the NB Unit and Connecting Peripheral Devices fi Connecting to a CS series Ethernet IP Unit Note 1 Always turn OFF the power to the PLC before setting the rotary switches 2 Create I O tables for the CPU Unit when setting the unit number for the first time or changing settings CS series EtherNet IP Unit CS1W EIP21 Setting the Front Panel Switches Setting Unit Numbers Always set the unit numbers so that the unit numbers of other CPU Bus Units mounted to the same CPU Unit are all unique Use a small screwdriver to set the rotary switches being careful not to damage them The factory setting is 0 Setting range OtoF Setting Node Numbers Use the node address switches to set the node address to a unique hexadecimal value Do not set it to the same value as any other Ethernet IP Unit or built in port on the same Ethernet IP network As long as it does not duplicate the address of any other Ethernet IP Unit or built in port the node
52. al Name at the PC side Connector 9 pin Connector COM female NB Unit side DB9 Serial Port at the PC side RS232 DB9 male at the NB Unit side Signal Name Pin No Shielded Cable Pin No Signal Name at the PC side Connector 80009 A AE 1 6 Note As to the 2 connection methods introduced above the No 2 3 9 pins of COM1 on the unit side have the same definitions as those described in the above diagram and the method for connection to a PC is also the same as above NB series Programmable Terminals Setup Manual V107 A 13 Od uonoeuuoo 10 ejqeo eu Buneouqe 10 POLJAN G p v au Jo p v Appendices A 5 List of Models EE NB Unit USB Models Resolution Size Communication Equivalent of USB 2 0 Full Speed NB3Q TWOOB QVGA 320X 240 3 5 inches 1 Slave NB3Q TWO1B QVGA 320X 240 3 5 inches COM1 Ethernet Host Slave NB5Q TWOOB QVGA 320X 234 5 6 inches 1 COM2 Slave NB5Q TWO1B QVGA 320X 234 5 6 inches COM 1 COMO Ethernet Host Slave NB7W TWOOB WVGA 800X 480 7 inches 1 2 Slave NB7W TWO1B WVGA 800X 480 7 inches 1 2 Ethernet Host Slave NB10W TWO1B WVGA 800X 480 10 1 inches COM COMO Ethernet Host Slave Serial Communication Unit Models Specifications Applicable PLCs CS1W SCU 21 RS 232C 2 ports CS series CS1G H CS1G H H CS1W SCU31
53. als Setup Manual V107 Authorized Distributor
54. ample Set the Unit No of the serial communication Unit by the rotary switch on the front side of the Unit Use a straight screwdriver set the switches as follows to display the numbers and symbols shown in the table Unit number settings Set it to 0 F in order to avoid duplicating other Units 2 24 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices When connecting to a CJ1 Series Serial Communication Unit For CJ1W SCU21 type Both of port 1 and 2 are RS 232C ports For CJ1W SCU31 type Both of port 1 and 2 are RS 422A 485 ports Unit version1 3 For CJ1W SCUA1 type Port 1 is RS 422A 485 port and Port 2 is RS 232C port Settings for the DM Fixed Allocation Area of the CPU Unit Write settings directly to the DM Fixed Allocation Area of the CPU Unit System Settings Area with a peripheral tool programming console or CX Programmer After finishing the write in the settings can be activated through any of the methods of reconnecting the power supply restarting the Unit reactivating the communication port executing the STUP instruction uon2euuo UOHeIIUNWIWOD Jenas t z The followings are the Channel Nos and settings of the DM Fixed Allocation Area It is the same when using RS 232C RS 422A N m DM30000 100 x Unit No CH S DM Fixed Allocation Area CH A Write Value Setting Port 1 Port 2 o m 10 8000 Use Host Link
55. at are provided are extremely important to safety Always read and heed the information provided in all safety precautions Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Additionally there may be severe property damage Precautions for Safe Use Indicates precautions on what to do and what not to do to ensure using the product safely Precautions for Correct Use Indicates precautions on what to do and what not to do to ensure proper operation and performance Note Indicates suggestive information and precautions on operation of the product Symbols Prohibition Indicates a general prohibition Caution Indicates general cautionary warning or danger level information 12 NB series Programmable Terminals Setup Manual V107 AWARNING Do not attempt to take the product apart and do not touch the product inside while the power is being supplied Otherwise it may result in electric shock Always ensure that the personnel in charge confirm that installation inspection and maintenance were properly performed for the NB Unit Personnel in charge refers to individuals qualified and responsible for ensuring safety during machine design installation operation maintenance and disposal Ensure that installation and post installation checks are performed by personnel in charge who possess a thorough understanding of th
56. at hand for reference during installation and operation NB series Manuals NB series manuals are organized in the sections listed in the following tables Refer to the appropriate section in the manuals as required Programmable Terminals Setup Manual Cat No V107 This Manual Section Section 1 Part Names and Functions Contents This section describes the names and functions of the various parts of an NB Unit Section 2 Installing the NB Unit and Connecting Peripheral Devices This section describes the methods used to install the NB Unit and connect peripheral devices Section 3 System Setting Mode This section describes the System Setting Mode Section 4 Calibrate Mode This section describes the Calibrate Mode Appendices The appendices provide information on specifications dimensions wirings and lists of the NB Units the applicable PLCs and options Programmable Terminals NB Designer Operation Manual Cat No V106 Section Section 1 Introduction Contents This section provides an outline of the NB series PTs including their functions features connection types and communication methods Section 2 Installation and Startup of NB Designer This section describes how to install and start the NB Designer Section 3 Functions of NB Designer This section describes the functions of NB Designer Section 4 Functions of NBManager This section describes the funct
57. ated Precautions for Safe Use Confirm the safety of the system before turning ON or OFF the power supply or pressing the reset button NB series Programmable Terminals Setup Manual V107 2 7 2 Installing the NB Unit and Connecting Peripheral Devices 2 3 Connecting of NB series with PC In order to transmit the screen data established by the NB Designer to the NB Unit the NB Unit needs to be connected to a PC with a RS 232C USB or Ethernet cable 2 3 1 Connecting by RS 232C NB5Q NB7W TWO1B as example Connect the RS 232C cable at the PC side to the serial port COM1 of the NB Unit Communication conditions Select the downloader mode through the tool menu of the NB Designer For details refer to 3 15 Download in the NB Designer Operation Manual Communication cable Users can make connection cables by themselves For details refer to A 4 Fabrication of the Connection Cable in the NB Series Setup Manual 2 8 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 3 2 Connecting by USB Use the USB transmission cable to connect the USB A type port on PC side with the USB SLAVE B type port on NB Unit As to the USB connection there are some preparations and restrictions that need to be done or heeded Refer to the following content to ensure a correct connection Take NB5Q NB7W TWO1B as example Connect the USB port at the PC side and the USB s
58. ble check the connection with a 10Base T cable tester Environment Precautions The UTP cable is not shielded and the hub is designed for use in OA environments In environments subject to noise construct a system with shielded twisted pair STP cable and hubs suitable for an FA environment Do not lay the twisted pair cable together with high voltage lines Do not lay the twisted pair cable near devices that generate noise Do not lay the twisted pair cable in locations subject to high temperature or high humidity Do not lay the twisted pair cable in locations subject to excessive dirt and dust or to oil mist or other contaminants Hub Installation Environment Precautions Do not install the hub near devices that generate noise Do not install the hub in locations subject to high temperature or high humidity Do not install the hub in locations subject to excessive dirt and dust or to oil mist or other contaminants Connecting the Cable Note 1 Turn OFF the PLC s power supply before connection or disconnecting twisted pair cable 2 Allow enough space for the bending radius of the twisted pair cable 1 Lay the twisted pair cable 2 Connect the cable to the hub Be sure to press in the cable until it locks into place Request cable installation from a qualified professional 3 Connect the cable to the connector on the PLC Be sure to press in the cable until it locks into place 2 28 NB series Programmable Ter
59. ces The following products are recommended for configuring the network when an Ethernet Unit is used Part Maker Model number Specifications Inquires Hub 100BASE TX OMRON WAS1 03B 10 100 Mbit s 3 port hub OMRON WAS1 05B C 10 100 Mbit s 5 port hub Phoenix SWITCHSTX 10 100 Mbit s 5 port hub Contact 10BASE T AlliedTelesis MR820TLX 9 port hub with 10Base Allied Telesis 0120 5backbone port 86 0442 in Japan only Twisted pair cable 100BASE TX Fujikura F LINK E0 5mm x STP shielded twisted 4P pair cable Category 5 5e Note Impedance is limited to 100 Fujikura CTP LAN50 5mm UTP unshielded twisted x 4P pair cable Category 5 5e 10BASE T Fujikura 0 5 STP shielded twisted 4P pair cable Category 3 4 5 5e Note Impedance is limited to 100 Fujikura CTP LAN50 5mm UTP unshielded twisted x 4P pair cable Category 3 4 5 5e Connectors Modul STP Plug ar plug Panduit Corp MPS588 zn UTP Plug Panduit Corp MP588 C NB series Programmable Terminals Setup Manual V107 2 27 uomnoeuuo uoneoiunuluo 5 S Z VIA ISOH 1 9 2 2 Installing the NB Unit and Connecting Peripheral Devices Precautions on Laying Twisted pair Cable Basic Precautions Press the cable connector in firmly until it locks into place at both the hub and the PLC After laying the twisted pair ca
60. e Unit port into the RS 232C into the RS 232C port built in the CPU port built in the CPU Unit and the Unit and the peripheral port When peripheral port connecting to the peripheral port a RS 232C adaptor CPM1 CIFO1 type is also needed to be connected CQM1H Connect to the RS 232C port built in the Connect to the RS 422A port Port 2 of CPU Unit the serial communication board Connect to the peripheral port with a conversion cable CS1W CN118 type Connect to the RS 232C port Port 1 of the serial communication board PLC System Settings Area Write settings directly into the PLC System Settings Area Data memory with a peripheral tool CX Programmer etc based on the model and port of the host For RS 232C Host Model Setting The RS 232C port built in DM6645 0001 Use Host Link C200HX HG HE Z DM6646 OSLILI 3 Communication conditions are standard settings 4 COMIF MEAS 10000 Unit No 00 CPM1A DM6650 0001 Use Host Link DM6651 OSLILI 3 Communication conditions are standard settings 4 DM6653 0000 Unit No 00 Port A of DM6555 0001 Use Host Link C200HX HG HE Z 1 DM6556 O3LIL 3 Communication conditions are standard settings 4 Port 1 of COMIE C2 pesa 0000 Unit No 00 Port B of DM6550 0001 Use Host Link C200HX HG HE Z 1 DM6551 031111 3 Communication conditions are standard settings 4 DM6553 0000 Unit No 0
61. e machinery to be installed Do not use the input functions of the touch switch etc of the NB Unit in applications that involve human life in applications that may result in serious injury or for emergency stop switches Do not attempt to disassemble repair or modify the NB Unit Otherwise it may impair the safety functions Never press more than two points on the touch panel of the NB Unit at a time Otherwise it may activate a switch somewhere between the two points OOOP PO NB series Programmable Terminals Setup Manual V107 13 Precautions for Safe Use 14 When unpacking the NB Units and the peripheral devices check carefully for any external scratches or other damages Also shake the Units gently and check for any abnormal sound The NB Unit must be installed in a control panel The mounting panel must be between 1 6 and 4 8 mm thick Tighten the Mounting Brackets evenly to a torque of between 0 5 0 6 N m to maintain water and dust resistance If the tightening torque exceeds the specified value or the tightening is not even deformation of the front panel may occur What is more make sure the panel is not dirty or warped and that it is strong enough to hold the Units Do not let metal particles enter the Units when preparing the panel Do not connect an AC power supply to the DC power terminals Use a DC power with a slight voltage fluctuation and that will provide a stable o
62. e the connector shield as shown below Aluminum The end connected Foil Tape The end not connected to the connector to the connector 10 NB series Programmable Terminals Setup Manual V107 Appendices A 4 4 Method for Fabricating the Cable for Connection to OMRON PLC When fabricating the cable for connecting the NB Unit and OMRON PLC refer to the following methods 1 The cable for connecting the Unit serial port COM1 to OMRON PLC RS 232C RS232 port at the COM female NB Unit side OMRON PLC side OMRON PLC side at the NB Unit side Signal Name Shielded Cable Pin SignalName female E 6 O7 8 9 CS CTS gt The cable for connecting the NB3Q Unit serial port COM1 to OMRON PLC 5 422 8 COM female NB Unit side OMRON PLC side 5 at the NB Unit side 9 1 e sbdB 1 z d 2 8 B e o T 5 9 Note If the RS 485 connection is adopted all needed to do is to connect the No 6 and No 8 pins and the shielded cable to the corresponding pins on the PLC side The cable for connecting the NB5Q NB7W NB10W Unit serial port COM1 to OMRON PLC RS 232C RS232 port at the COM1 female NB Unit side OMRON PLC side OMRON PLC side at the NB Unit side Signal Name Shielded Cable Pin SignalName female Connector 01 uonoeuuo JO ejqe9 DuneouqeJ 1
63. ecked in the FINS UDP Option check box after either of Auto dynamic Combined and IP address table is checked in the Conversion check box When insert the IP address into the IP Address Table after the IP address table or Combined is checked do not make the Node ID of NB into it 1 1 If the Node ID of NB is placed into the IP Address Table the system will require the NB to use the same port with the PLC and PLC response error information will appear on NB The prompts for possible errors occurred to NB when FINS UDP protocol is adopted are described as follows PLC Response Error Response to the abnormal information caused by the Read Write command to PLC PLC No Response No response is made by PLC and represents HMI No Node ID of PLC Port Number 2 42 NB series Programmable Terminals Setup Manual V107 System Setting Mode This section describes the System Setting Mode 3 1 Display Method of System Setting 3 2 3 2 Functions of System Setting Mode 3 3 NB series Programmable Terminals Setup Manual V107 3 1 3 System Setting Mode 3 1 Display Method of System Setting Mode Enter the System Setting Mode following the procedures below 1 Set both the DIP switches SW1 and SW2 on the back side to ON 2 Press the Reset switch restart the NB Unit and then it enters into the System S
64. ector with the same shape of the CS Series peripheral port but the signal cables inside are classified as used for the RS 232C port built in the CPU Unit and for the peripheral port Therefore when using 2 differentiate between the settings for the RS 232C port built in the CPU and for the peripheral port based on the conversion cable and port employed to ensure correct use Besides when using a simple communication device CPM2C CIF21 type connect to the RS 232C port For details refer to the CPM2C Operation Manual W356 Use a self made connection cable to connect the NB Unit and CPM2C Connect to CPM2C s built in RS 232C port instead of the peripheral port Port connected to the PT PLC System Settings CS1W CN118 type port D Sub 9 pin Carry out settings for the built in RS 232C port CPM2C CS1W CN118 type RS 232C port D Sub 9 pin socket When using a simple communication device CPM2C CIF21 type connect to the RS 232C port directly RS 232C port NB series Programmable Terminals Setup Manual V107 2 15 2 Installing the NB Unit and Connecting Peripheral Devices Settings for the front side DIP Switches To activate the settings of PLC System Settings Area Data memory set as follows according to the PLC For C200HX HG HE Z and RS 232C of COM1H For C200HX HG HE Z For COM1H ON 4 gt Communication condition setting for the RS 232C port Set the DIP switch 5 to OF
65. edge of electrical systems an electrical engineer or the equivalent Personnel in charge of introducing FA systems into production facilities Personnel in charge of designing FA systems Personnel in charge of installing and connecting FA facilities Personnel in charge of managing FA systems and facilities General Precautions NB series Programmable Terminals Setup Manual V107 The user must operate the product according to the performance specifications described in the operation manuals Do not use the PT touch switch input functions for applications where danger to human life or serious property damage is possible or for emergency switch applications Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems railroad systems aviation systems vehicles combustion systems medical equipment amusement machines safety equipment and other systems machines and equipment that may have a serious influence on lives and property if used improperly consult your OMRON representative Make sure that the ratings and performance characteristics of the product are sufficient for the systems machines and equipment and be sure to provide the systems machines and equipment with double safety mechanisms This manual provides information for connecting and setting up an NB Series PT Be sure to read this manual before attempting to use the PT and keep this manual close
66. es and functions of the various parts of an NB Unit 4 1 Part Names ic EIER ee ee 1 2 1 2 Part Specifications 1 6 NB series Programmable Terminals Setup Manual V107 1 1 1 Part Names and Functions 1 1 Part Names NB3Q TWOOB NBS3Q TWO1B model Front view POWER omnon Power Indicator Display Back view HHHHHHHHHHHUHHHBHHHH 9 Swi SW2 MODE ON ON System Setting Mode OFF Calibrate Mode nm ON OFF Downloader Mode OFF OFF User Project Mode sw3 ON Terminating Resistor ON OFF Terminating Resistor OFF SW4 Is reserved 5 RESET MODE 1 ETHERNET 5 Tk Anal Precautions for Safe Use Confirm the safety of the system before turning ON or OFF the power supply or pressing the reset button 1 2 NB series Programmable Terminals Setup Manual V107 1 Part Names and Functions NB5Q TWOOB NB5Q TWO1B model Front view y 2 z o 3 o Power Indicator Display Back view
67. etting Mode 3 2 NB series Programmable Terminals Setup Manual V107 3 System Setting Mode 3 2 Functions of System Setting Mode The following items can be set in System Setting Mode 1 Time calibration check whether the year month day hour minute and second are the current time values and if not rectify them manually 2 IP Address Only supported by NBLILI TWO1B Sets the IP address for HMI Port Only supported by NBLILI TWO1B Sets the port number Subnet Mask Only supported by NBLILI TWO1B Sets the subnet mask Gateway Only supported by NBLILI TWO1B Sets the gateway 3 Startup Window No the window displayed after launching the NB Unit The default is window O 4 Backlight Saver Time time to activate the screen saver and the Unit is minute The default is 10 minutes The screen saver is not brought into effect when the set value is O 5 Mute Enabled Disabled ON OFF of the buzzer 6 Brightness Up Down with this brightness of the screen can be adjusted bringing the screen to its best visual effect 7 Export Import Only supported by NBLILI TWO1B USB HMI Uploads the user project file pkg required by the HMI operation to the USB memory And the upload password is required during the export If the upload password is not set it needs to use the default password of 888888 po Dunes weiss jo suonoung 2 6 USB gt HMI Downloads the user project file pkg in USB memory to HMI RCP
68. g data EE 7 Not used 8 Not used NB series Programmable Terminals Setup Manual V107 1 Part Names and Functions DIP Switch NB5Q NB7W only has 2 switches SW1 SW2 while for the NB3Q and NB10W there are totally 4 DIP switches and for all models SW1 SW2 feature the same functions The settings and corresponding operating modes are as follows 5 ON swi Sw2 Operating modes a 1 ON ON System Setting Mode i 12 OFF ON Calibrate Mode ON OFF Downloader Mode OFF OFF User Project Mode System Setting Mode The PT will be launched into a built in system setup screen and is subject to the user for brightness system time and buzzer settings Calibrate Mode When the user touches the panel a symbol will pop up on the screen with which the touch control precision level can be calibrated Downloader Mode This is used for basic operations such as updating the firmware downloading and uploading the user s engineering documents etc and this mode is not intended for general users User Project Mode This is the User Project Mode of NB Series PTs The PT will display the startup screen of the project already downloaded As mentioned above the settings and corresponding operating modes of the switches SW1 and SW2 of and NB10W are the same as those of NB5Q NB7W see the table above and the functions of SW3 SW4 of NB3Q and NB10W are stated as below
69. ies connectable to NB Series through the Ethernet Unit PLC Series Specifications CP Series Connecting through the Ethernet optional communication board CJ1W CIF41 CS Series Connecting through the Ethernet Unit CS1W ETN21 or CS1W EIP21 CJ1 Series Connecting through the Ethernet Unit CJ1W ETN21 or CJ1W EIP21 CJ2 Series Connecting through the Ethernet Unit CJ1W ETN21 or CJ1W EIP21 NB series Programmable Terminals Setup Manual V107 SI PON Jo 1611 S V Od uonoeuuoo 10 10 POUAN S p v Appendices Units at the host side which can be connected using the serial port of the NB Unit in the RS 232C mode through Host Link PLC Series CP Series CPU Unit with built in Host CPU Unit that can be connected through adding Host Link Options required for Ein fUngion Units communication boards connection CP1L L14 L20 M30 M40 M60 CP1W CIF01 CP1H X40 XA40 Y20 CP1W CIF01 CP1E N14 N20 CP1E N30 N40 N60 NA20 CP1E N30 N40 N60 NA20 CP1W CIF01 CP1L EL20 EM30 EM40 CP1W CIF01 C Series C200HE CPU11 32 42 C200HE CPU11 32 42 Z C200HG CPU33 43 53 63 C200HG CPU33 43 53 63 Z C200HX CPU34 44 54 64 C200HX CPU34 44 54 64 65 85 Z C200H LK201 V1 C200HE CPU42 C200HE CPU32 42 C200HW C200HE CPU42 Z C200HE CPU32 42 Z COMO02 04 05 06 V 1 C200HG CPU43 63 C200HG CPU33 43 53 63 C200HW C200HG CPU43 63 Z C200HG CPU33 43 53 63 Z 02 04 05 06 1 C200HX CPU44 64 C200HX CPU34 44
70. iguration The result is shown as below Network Config IP Addr Master Slave HMIO 192 168 250 1 9600 Omron CJ Series Fins UDP M 1 PLCO 192 168 250 2 9600 Omron CJ Series Fins UDP Slave 5 2 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 5 3 Host Types and Settings of Ethernet Unit Units that are used for Ethernet communications vary according to the type and series of OMRON PLC used When connecting an Ethernet Unit check the series and type of the PLC that it will be connected to and the model of the Unit that is mounted to the PLC 5 S Z NB series PTs and the following Controllers can be connected with Ethernet units Ethernet Unit CS1W ETN21 Series name Using the built in board Using an Ethernet Unit CS Series CS1G H CPULILI V1 CS1G H CPULILIH CS1D CPULILIH CJ Series CJ1G H CPULILIH CJ1M CPULILI ETN CJ1M CPULILI ETN CS1W ETN21 CJ1W ETN21 m I 9 2 CJ1W ETN21 2 CJ2M CPUOO i CP1H Series 1 CJ1W ETN 1 1 CP1W CIF41 1 m CP1L Series CP1L L14 20 CP1W CIF41 3 CP1L M30 40 60 CP1L EL20 5 CP1L EM30 40 CP1E Series CP1E N30 CP1W CIF41 CP1E N40 CP1E N60 CP1E NA20 For details on the hosts that can be connected to NB se
71. ions of NBManager Section 5 Maintenance and Abnormality Handling This section describes the maintenance and check to prevent the abnormality occurrence and the handling of the abnormalities occurred in NB Unit Section 6 Descriptions of New Functions Added into NBLILI TWO1B This section describes the new functions added into NBLILI TWO1B the system attributes and the component attributes Appendices The appendices provide lists of the NB Units the Communication Units the applicable PLCs and the list of NB Designer functions NB series Programmable Terminals Setup Manual V107 Programmable Terminals Host Connection Manual Cat No V108 Section Section 1 List for PLCs Supported by NB series Contents This section lists all PLCs supported by NB Units Section 2 Connecting to SIEMENS PLCs This section describes the connection to SIEMENS PLCs Section 3 Connecting to Mitsubishi PLCs Section 4 Connecting to Schneider PLCs This section describes the connection to Mitsubishi PLCs This section describes the connection to Schneider PLCs Section 5 Modbus Connection This section describes the connection on Modbus protocol Section 6 Connecting to Delta PLCs This section describes the connection to Delta PLCs Section 7 Connecting to LG PLCs This section describes the connection to LG PLCs Section 8 Connecting to Panasonic PLCs This section describes the c
72. ization i e the NIC in the country of use such as the JPNIC in Japan Using IP addresses that are not recognized by the NIC JPNIC to connect to the Internet could have unforeseen social consequences such as causing the networks of another organizations to malfunction unexpectedly 2 32 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices Local IP Address The local IP address indicates the IP address of the Ethernet Unit that is used to set the settings The following IP address settings are not possible Net ID with all bits set to O or 1 Host ID with all bits set to O or 1 Subnet ID with all bits set to 1 IP addresses that begin with 127 7F Hex e g 127 35 21 16 uonoeuuo daf SNI4 S Z Subnet Mask When more than one node is connected to the network network operation and management can be difficult Therefore for convenience configure the system by dividing a single network into multiple sub networks The system operates internally as multiple networks but externally appears as a single network To operate a system in this way divide the host ID field of the IP address into a subnet ID field and a host ID field The subnet ID field is identified by the information in the subnet mask The subnet mask is a bit mask in which the net ID and subnet ID fields are 1 and the host ID field is O Example 11111111 11111111 11111111 000
73. l HMI Indicates an OMRON Programmable Terminal NB series Programmable Terminals Setup Manual V107 NB series Programmable Terminals Setup Manual V107 CONTENTS Introduction L 1 NB series Manuals 5 5 bo inen e n iai Ex E EV Ka FUE ds 2 Manual Structure t 4 Terminology 5 Safety Precautions irse cease cin ka ano tx IU vao nu 12 Precautions for Safe Use croient eic rade se ca aa a s CX i a ld a 14 Precautions for Correct Use necessa taza ia Eo anco inan R Edna E Mx r Feu a SapR UN DRE aai 16 Conformance to EC enne nnne 17 Related pr n 18 Sec 1 Part Names and 1 1 151 Pair eterne er 1 2 1 2 Part Specificatioris ete adesse 1 6 Sec 2 Installing the NB Unit and Connecting Peripheral Devices 2 1 2 1 Installing the NB 2 2 2 1 1 Installation environment ceo eec n tm a replete etel a e 2 2 2 1 2 Installation onto the Operation Panel nennen nnne nnne 2 3 2 1 3 Connecting the Power
74. lave connector of the NB Unit Od seues gw 6 2 gsn Aq z z USB driver for the NB Designer A USB driver needs to be installed in the PC for the purpose of transmitting screen data through USB The USB driver should be installed at the first time when connecting the NB Unit to a PC Please refer to 2 4 Installation of USB Driver for NB in the NB Designer Operation Manual for details on the USB driver Precautions for Safe Use Commercially available and the recommended USB HUBs are different from the general specifications of the NB Unit The Unit may not function well in an environment subject to noise static electricity Therefore when using a USB HUB employ sufficient noise and static electricity insulation measures or install it at a site free of noise or static electricity Do not connect a USB connector to any device that is not applicable Before connecting a USB connector to a device make sure that the device is free of damage NB series Programmable Terminals Setup Manual V107 2 9 2 Installing the NB Unit and Connecting Peripheral Devices 2 3 3 Connecting by Ethernet HMI with model number of NBLILI TWO1B other than NBLILI TWOOB can perform the uploading amp downloading of data such as user project and recipe etc and the refreshing of HMI firmware through connecting the Ethernet cable with RJ45 connectors on both ends and the network interface on PC
75. llation conditions in applications where the PT is subject to contact with oil or water Do not perform the following operations during the communication of the USB memory Turning off the power supply of the NB Unit Pressing the Reset button on the NB Unit Removing the USB memory Do not use the USB memory in the environment subject to strong vibration NB series Programmable Terminals Setup Manual V107 15 Precautions for Correct Use 16 Do not install the unit in any of the following locations Locations subject to severe changes in temperature Locations subject to temperatures or humidity outside the range specified in the specifications Locations subject to condensation as the result of high humidity Locations subject to corrosive or flammable gases Locations subject to strong shock or vibration Locations outdoors subject to direct wind and rain Locations subject to strong ultraviolet light Locations subject to dust Locations subject to direct sunlight Locations subject to splashing oil or chemicals Take appropriate and sufficient countermeasures when installing systems in the following locations Locations subject to static electricity or other forms of noise Locations subject to strong electric field or magnetic field Locations close to power supply lines Locations subject to possible exposure to radioactivity Precautions for software The update restoration uninstall and reinstallation of software in
76. minals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 5 2 Parameter Settings for FINS UDP at NB Side After placing the desired HMI and PLC into the Construct Window select Network Device Setting in the Option menu and then click the Add button after the Network Device Setting dialog box pops up After selecting the Device Type and the related FINS UDP protocol you can make settings of IP Address Node ID and Network No and etc for the HMI 2 daf SNI4 S Z Network Device Setting Device Type C PLC PLC Communication Setting PLC Communication Type DI Device No PLC Communication Time Out s 1 Protocol Time Out 1 ms 1 Protocol Time Out 2 ms 1 IP Address 192 168 250 1 Port Num 9600 Max interval of word block pack 9 Max interval of bit block pack 16 Comm Protocol Omron CJ Series F Max word block package size 1 Node ID 1 Max bit block package size 16 Use Default Setting Network NO Default 0 CP1E EUN 5 ini C User Defined OK Note When there is CP1E PLC in the FINS UDP network architecture the Network No should be 0 Otherwise the communications through the FINS UDP protocol between the NB and CP1E in this architecture will be impossible The settings of IP Address Node ID and related communication parameters for PLC can be made AN 1 dAN SNIH 10 58 14
77. n models series There is also the CPU Unit connected in a Host Link method through adding the serial communication board or communication board When connecting confirm the connected PLC s series model and the models of the installed circuit board Unit As to the Units at the host side which can be connected to NB series Unit by RS 232C or RS 422A through a Host Link refer to A 5 List of Models in the NB Series Setup Manual NB series Programmable Terminals Setup Manual V107 2 11 2 Installing the NB Unit and Connecting Peripheral Devices Communication setting The communication settings need to be set as following values before carrying out communications in the Use Host link Items Settings Data bit 7bit Stop bit 2bit Parity check Even Communication speed Any value but the values for the NB Unit and the host must be the same Connected Unit No 00 At the NB Unit side these settings are made through the PT menu of the NB Designer For details refer to 3 10 8 1 2 Setting in the NB Designer Operation Manual For communication settings at the host side refer to the related PLC manuals as needed 2 4 2 Connecting more than one PLC Select the RS 232C method for COM1 and one from RS 232C RS 422A and RS 485 for COM2 NB3Q TWLILIB is not equipped with serial port COM2 PT with the model number of NBLILI TWO1B which supports Ethernet can connect single PLC or multiple PLCs simultaneously thr
78. nd transparent with 1 set containing 5 pieces NB Unit Models Models Specifications NB3Q TWLILIB NB3Q KBA04 5 pieces NB5Q TWLILIB NB5Q KBA04 NB7W TWLILIB NB7W KBAO4 NB10W TWO1B NB10W KBA04 Installation fittings Models Descriptions NB5Q ATTO1 When HMI users switch from the NT31 C or NQ5 Series to HMI of NB5Q Series due to the difference of the unit size installation fittings can be utilized to guarantee the process quick and smooth NB10W ATTO1 When HMI users switch from the NB10W TWOOB Z Series to HMI of NB10W TWO B Series due to the difference of the unit size installation fittings can be utilized to guarantee the process quick and smooth suondo 101611 9 V Od uonoeuuoo 10 ejqeo 10 POAN G p v NB series Programmable Terminals Setup Manual V107 19 Appendices A 20 RS 422A RS 485 Communication Cable Models NB RSEXT 2M Descriptions Only applies to the port of the NB series product when performing communications using RS 422A RS485 can be equipped with this communication cable NB Model NB5Q NB7W sese cere shield wire NB3Q TWLILIB NB10W TWOOB signal wire ed 3 RD RD White Blue Brown Black Conform to UL2464 AWG28 Instruction When users need to carry out long distance signal transmission can connect with terminal matching resistance How to use When using NB5Q NB7W NB10W TWLILIB Unit open RS
79. ng the Rear Panel Switches Setting Local IP Addresses Set the local IP address for the Ethernet Unit using the eight hexadecimal rotary switches local IP address setting switches expressing each 4 bit value as a single hexadecimal digit Set the IP address as hexadecimal using the eight switches combining SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 as shown in the following diagram Setting range for each switch SW8 SW7 k SW6 e SW5 Local IP address 1 2 3 4 5 6 7 8 Example Setting 130 58 17 32 Decimal This address will be 82 3A 11 20 in hexadecimal so the switch would be set as shown in the following table Switch Setting Local IP address in hexadecimal Local IP address in decimal EN Additional Information When converting the data by automatic generation method default method please set the node numbers to be consistent with the values of local IP address setting switches SW7 SWS and set ID thresholds for other Hosts to 0 If the Host ID value corresponding to the IP address is not consistent with the node number the ERC indicator will flash Please use the CX Programmer to set the subnet mask for the CPU Bus Unit Setup Area 2 34 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices Ethernet Connectors C
80. o ON upwards Selection of Link Type DIP switch Set it to 1 for 1 ON upwards NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices When connecting to a CS Series Serial Communication Board For CS1W SCB21 type Both of port 1 and 2 are RS 232C ports For CS1W SCB41 type Port 1 is RS 232C port and Port 2 is RS 422A 485 port Serial Communication Board for CS Series CPU Units with RS 232C port RS 422A port Settings for the DM Fixed Allocation Area of the CPU Unit Write settings directly to the DM Fixed Allocation Area of the CPU Unit System Settings Area with a peripheral tool programming console or CX Programmer After finishing the write in the settings can be activated through any of the methods of reconnecting the power supply restarting the Unit reactivating the communication port executing the STUP instruction The followings are the Channel Nos and settings of the DM Fixed Allocation Area uon2euuo UOHeIIUNWIWOD Jenas t z It is the same when using RS 232C RS 422A port 2 of the CS1W SCB41 type DM Fixed Allocation Area CH e Write Value Setting o Port 1 Port 2 2 DM32000 DM32010 8000 Use Host Link 2 DM32001 DM32011 0000 000A 1 Communication speed 5 DM32003 DM32013 0000 Unit No 00 8 c 3 1 The communication speed should be set to the same value as that of the NB Unit Setting
81. o change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the products may be changed without any notice When in doubt special model numbers may be assigned to fix or establish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown PERFORMANCE DATA Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty and Limitations of Liability ERRORS AND OMISSIONS The information in this manual has been carefully checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions NB series Programmable Terminals Setup Manual V107 11 Safety Precautions Notation Used for Safety Information The following notation is used in this manual to provide precautions required to ensure safe usage of the product The safety precautions th
82. onnection to Panasonic PLCs Section 9 Connecting to Allen Bradley Rockwell PLC This section describes the connection to Allen Bradley PLC Section 10 Connecting to PLC of GE Fanuc Automation Inc This section describes the connection to PLC of GE Fanuc Automation Inc Programmable Terminals Startup Guide Manual Cat No V109 Programmable Terminals Startup Guide Manual Cat V109 Section Section 1 NB Overview Contents This section provide specifications of the NB Unit describes its names and functions of the various parts Section 2 System Design This section describes the manual structure takes NB7W as an example to introduce the operation procedures of the NB system Section 3 Installation and Wiring This section describes how to install and wire the NB Unit Section 4 Screen Creation This section describes how to create a demonstration project through NB Designer Section 5 Run This section describes how to start running at the Host side and prepare to send screen data to NB7W Section 6 Maintenance and Troubleshooting This section describes the maintenance and inspection methods for preventing errors occurring and troubleshooting measures when errors occur Failure to read and understand the information provided in this manual may result in personal injury or death damage to the product or product failure Please read each section in its entirety and be
83. ough the Ethernet through the router When connecting with multiple PLCs it can connect the Host manufactured by the same manufacture or different manufactures simultaneously Note At a certain time only one from RS 232C RS 422A and RS 485 can be designated for COM2 to perform communications The example of NB5Q NB7W NB10W TW01B connecting with PLCs simultaneously is as shown below NB Unit NB Unit 1 1 RS 232C cable COM RS 232C 422A 485 cable NB Unit 2 NB Unit 3 Ethernet cable Precautions for Safe Use Always keep the connector screws firmly tightened after the communication cable is connected The maximum tensile load for cables is 3ON Do not apply loads greater than this The communication cables of the COM1 and COM connectors are not interchangeable Confirm the pins of the ports before carrying out communications 2 12 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices 2 4 3 Settings for each Unit When connecting with the serial communication ports the settings for each Unit are as follows i When connecting to CP Series Units CP1L L14 L20 M30 M40 M60 models 40 40 20 models CP1E N14 N20 models CP1E N30 N40 N60 NA20 models CP1E EL20 EM30 EM40 models Jenas t z PLC System Settings Area Y A Write settings di
84. pb or above to or delivering them through California USA the following precautionary measures have to be publicized Perchlorate material applicable through special processing Refer to http www dtsc ca gov hazardouswaste perchlorate NB Series products contain lithium primary batteries When exporting products containing this kind of batteries to or delivering them through California USA label all the product packages as well as the appropriate delivery packages Do not use benzene paint thinner or other volatile solvents and do not use chemically treated cloths Do not dispose the Units together with general waste at waste yards When disposing them follow the related local ordinances or rules Customers may not replace the backlight lamp inside the NB Unit Please contact OMRON s customer service center Deterioration over time can cause the touch points to move Calibrate the touch panel periodically Water and oil resistance will be lost if the front sheet is torn or is peeling off Do not use the Unit if the front sheet is torn or is peeling off The rubber packing will deteriorate shrink or harden depending on the operating environment Inspect and replace the rubber packing periodically The communication cables of the COM1 and COM connectors are not interchangeable Confirm the pins of the ports before carrying out communications NBSQ TWOOB and NB3Q TWO1B only have COM Periodically check the insta
85. pheral tool programming console or it can be set by transmitting the PLC System Settings set up by a peripheral tool CX Programmer to the CPU Unit For details about the PLC System Settings refer to SYSMAC CS Series Operation Manual W339 Settings for the front side Switches Set the DIP switches 4 or 5 as follows according to the NB Series port connected DIP Switch in the battery jar When connecting a NB Series Unit to a peripheral port set SW4 to ON communications carried out according to the PLC system settings When connecting a NB Series Unit to a RS 232C port set SW5 to OFF communications carried out according to the PLC system settings Peripheral Port Mainly used for connecting peripheral tools ect also used for connecting RS 232C devices RS 232C Port Mainly used for connecting RS 232C devices also used for connecting CX Programmer NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices When connecting to CJ1 Series CPU Units For CJ1G CPULILI type CJ1G H CPULILIH types and CJ1M CPULILI type Connection Methods Connect to the RS 232C port built in the CPU Unit or the RS 232C port of the communication board When connecting to the peripheral port a connection cable dedicated for the peripheral port is needed CS1W CN118 type Only RS 232C can be used for connection uon2euuo UONeIIUNWIWOD
86. r Ethernet Units connected to the same Ethernet network all have unique addresses As long as the addresses are unique they can be set between 01 and FE 1 to 254 decimal NODE _ 8 54 2 0 01 to FE 1 to 254 decimal SHAS _01 to FE 1 to 254 VR x16 599 cos SOY x16 Set the upper digit using the top rotary switch and the lower digit using the bottom rotary switch The factory setting is 01 Setting Local IP Addresses For CJ series Ethernet Units set the local IP address from the CX Programmer or other Support Software for the CPU Unit Refer to the SYSMAC CS CJ Series Ethernet Unit Operation Manual Cat No W343 for details on setting methods Ethernet Connectors CS1W ETN21 This is the connector used to connect the twisted pair cable to the Ethernet Electrical Characteristics Conforms to IEEE802 3 standards Connector Layout RJ45 8 pin modular connector conforms to 1508877 EN Additional Information e CX Programmer version 8 1 or higher is required when CP1W CIF41 is used I CP series PLCs CP series Ethernet Option Board CP1W CIF41 Setting Node Numbers Set the node number to a unique value Do not set it to the same value as any other Ethernet node on the same Ethernet network Refer to the following manuals for the setting procedures CP1H SYSMAC CP Series CP1H CPU Unit Operation Manual Cat No W450 CP1L SYSMAC CP Series CP1L CPU Unit Operation Man
87. rd may cause the screen to fail to function When using an equipment monitor confirm the safety of the system before carrying out the following operations Changing monitor data Changing operation mode Forced setup reset Changing the current value or the set value Do not connect a USB connector to any device that is not applicable When connecting the equipment with the USB HOST connector make sure the supply equipment s current capacity is below 150mA before using it The DC 5V voltage output of the NB Unit is 5V 5 and the maximum current is 150mA Before connecting a USB connector to a device make sure that the device is free of damage Commercially available and the recommended USB HUBs are different from the general specifications of the NB Unit The unit may not function well in an environment subject to noise static electricity Therefore when using a USB HUB employ sufficient noise and static electricity insulation measures or install it at a site free of noise or static electricity While uploading or downloading screen data or system programs do not perform the following operations that may corrupt the screen data or the system program Turning OFF the power supply of the NB Unit Pressing the PT s reset switch Dispose of the Units and batteries according to local ordinances as they apply ri 8 Rete When exporting products with lithium primary batteries containing perchlorate at 6p
88. rectly into the PLC System Settings Area with a peripheral tool CX Programmer etc based on the model and port of the host i Host model and Port No Channel No 1 Write Value Setting CP1L M30 M40 MOO serial port 1 144 8000 Use Host Link 5 CP1H X40 XA40 Y20 serial port 445 0000 000A 2 Communication speed 8 CP1L EM30 EM4O serial port 1 E 147 0000 001 Unit number 5 CP1L L14 L20 serial port 1 160 8000 Use Host Link CP1L M30 M40 MOO serial port 2 CP1H X40 XA40 Y20 serial port2 161 0000 000A 2 Communication speed CP1L EL20 serial port 1 CP1L EM30 EM40 serial port 2 163 0000 001F Unit number Host model and Port No Channel No Write Value Setting CP1E N14 N20 serial port 1 A617 15 12 0 Use Host Link CP1 2 ii 617 11 08 0 3 A 2 Communication speed serial por p A617 07 00 00 7 data bits 2 stop bits Even CP1E N30 N40 N60 NA20 A618 15 12 0 Use Host Link serial port 2 A618 11 08 0 3 A 2 Communication speed A618 07 00 00 7 data bits 2 stop bits Even 1 The channel No of CP1L H is PLC Setup area 2 The communication speed should be set to the same value as that of the NB Unit Settings for the front side DIP Switches Set the front side DIP switches so as to validate the settings for PLC System Settings Area Set the SW4 to OFF when serial port 1 is used set SW5 to OFF when serial port 2 is used As the has only one serial port it has no DIP switch SW5 B 19 CPILM
89. ries PTs via the Ethernet refer to A 5 List of Models Host Settings The types of hosts that can be connected to NB series PTs with the Ethernet and the host settings are as follows The following settings must be set at the host Item Host Settings Number of nodes 33 See note 1 Network number 0 127 See note 2 UDP port number 1024 to 65535 default is 9600 IP address 0 0 0 0 to 255 255 255 255 Subnet mask 0 0 0 0 to 255 255 255 255 Default gateway 0 0 0 0 to 255 255 255 255 Node number 0 to 254 See note 3 Note 1 The max total number of registered nodes by NB Designer in the network is 33 at least 1 NB series PT and 1 host included 2 If there is CP1E PLC in the actual network architecture the Network No must be set 0 3 The Node ID of 0 is equivalent to that of 1 default NB series Programmable Terminals Setup Manual V107 2 31 2 Installing the NB Unit and Connecting Peripheral Devices For the limitations to the Host parameters setting refer to 2 5 5 Parameter Settings for FINS UDP at Host Side IP Address Configuration The IP address is comprised of 32 bits of binary data consisting of the net ID and host ID The net ID is the address that identifies the network and the host ID is the ID that identifies the host node The IP address is divided into class A B and C Select the address system from among the classes according to the network configuration 31 23 0 bits Class A 0
90. running status is prohibited in order to guarantee the correct use of the product NB series Programmable Terminals Setup Manual V107 Conformance to EC Directives NB Series Programmable Terminals are EMC compliant Concepts OMRON products are electronic devices that are incorporated in machines and manufacturing installations OMRON PTs conform to the related EMC Directives see note so that the devices and machines into which they are built can more easily conform to EMC Directives The actual products have been through inspections and are completely in accordance with EMC directives However when they are built into customers systems whether the systems also comply with these Directives is up to the customers for further inspection EMC related performance of OMRON PTs will vary depending on the configuration wiring and other conditions of the OMRON equipment or control panel The customer must therefore perform final checks to confirm that the overall machine or device conforms to EMC standards Note The applicable EMC Electromagnetic Compatibility standards are as follows EMS Electromagnetic sensitivity EN61131 2 2007 EMI Electromagnetic Interference EN61131 2 2007 Conformance to EC Directives NB Series Programmable Terminals are EC compliant Heed the following precautions in order to ensure that the customer s overall machine and device conform to EC Directives 1 The PT must be installed in a control panel
91. s RS 232C communication function making it connectable to a controller which features RS 232C function and it can also be used for downloading programs or debugging for the product The pins are defined as follows Pins Signals Functions 2 SD Sending data 3 RD Receiving data 4 RS RTS Request to send 5 CS CTS Clear to send 6 DC 5V DC 5V output Max current 250mA 7 NC 8 NC 9 SG Signal ground Pins 4 and 5 are not used thus not compliant with RS or CS functions 1 6 NB series Programmable Terminals Setup Manual V107 Precautions for Safe Use When using the No 6 pin of the serial communications port COM1 connector for a voltage of DC 5V make sure the supply equipment s current capacity is below 250 mA before using it The DC 5V voltage output of the NB Unit is 5V 5 and the maximum current is 250 mA NB3Q TWLILIB NB3Q TWLILIB has only 1 serial port COM and this port supports communication based on RS 232C RS 422 and RS 485 of which only 1 connection mode can be applied at one time By means of the RS 232C mode PIN 2 5 it can be connected to a controller based on RS 232C 1 Part Names and Functions suoneoyioeds ed 2 1 can also be used for downloading programs as well as debugging for the product connected to a PC While with the RS 422 or the RS 485 mode PIN 1 PIN 6 8 only a PLC can be connected The pins
92. s for front side switches For RS 422A Port1 RS 232C Terminating resistance switch Set to ON right position Two wire four wire switch RS 422A 4 four wire right position RS 485 2 two wire left position Port2 RS 422A 485 NB series Programmable Terminals Setup Manual V107 2 23 2 Installing the NB Unit and Connecting Peripheral Devices When connecting to CS Series Serial Communication Unit For CS1W SCU21 type Both of port 1 and 2 are RS 232C ports For CS1W SCU31 type Both of port 1 and 2 are RS 422A 485 ports Unit version1 3 Settings for the DM Fixed Allocation Area of the CPU Unit Write settings directly to the DM Fixed Allocation Area of the CPU Unit System Settings Area with a peripheral tool programming console or CX Programmer After finishing the write in the settings can be activated through any of the methods of reconnecting the power supply restarting the Unit reactivating the communication port executing the STUP instruction The followings are the Channel Nos and settings of the DM Fixed Allocation Area m DM30000 100 x Unit No CH DM Fixed Allocation Area CH Write Value Setting Port 1 Port 2 m 10 8000 Use Host Link m 1 m 11 0000 000 1 Communication speed m 3 m 13 0000 Unit No 00 1 The communication speed should be set to the same value as that of the NB Unit Settings for the front side Switches CS1W SCU21 as an ex
93. st Twisted pair cable 10Base T 100Base T Connecting PT to Host with a Hub Multiple NBs and hosts can be connected using twisted pair cable and a hub Hub Twisted pair cable 10Base T 100Base T NB 1 NB2 Host 1 Host 2 The Ethernet FINS communication for NB series products is only limited the local network but the Ethernet communication cross the network segment is allowable with the prerequisite of using the router That s to say the supported FINS network is only limited to the local network but the various devices in the network can be cross the network segment Please take the following architecture as reference Twisted pair cable 10Base T 100Base T NBx 1 NBx PLCy 1 PLCy 2 26 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices X represents the amount of NB series products and y represents the amount of PLC The relationship between x and y must meet the following conditions e x21 gt 1 e lt 33 In this system architecture the system has only one network number And the unique ID i e Node ID is assigned to both NB and PLC in the system When the actual amount of configured devices NB series products PLC is greater than 33 the customer can create a new NB Designer project to handle this problem e Recommended Network Configuration Devi
94. tary switch The unit number is factory set to O Setting range Oto F dan SNl4 S Z Setting Node Numbers Set a FINS address for the built in Ethernet IP port With the FINS communications service multiple Ethernet IP Units including the CJ2 Unit built in Ethernet IP port connected by Ethernet are identified by their node addresses Using the node address switches set a unique node address in hexadecimal The same node address cannot be used by any other Ethernet IP Unit or Ethernet Unit connected on the same Ethernet network As long as it does not duplicate any other address the node address can be set from 01 to FE 1 to 254 in decimal MIB Mz NODE Setting range 0 00 OMS lt lt No 01 to FE hex 1 to 254 decimal ANY x16 NULL clar cd ed o Note The node address is factory set to 01 With the default setting the values set on these switches become the last two digits of the built in Ethernet IP port s IP address iun jo sBumes pue sed 5 2 The default IP address is 192 168 250 node address With the factory set node address of 01 the default IP address is 192 168 250 1 The Node ID of the dip switch here must be consistent with that of PLC in the Network Device Setting dialog box for the actual project created in the NB Designer Ethernet Connectors This is the connector used to connect the twisted p
95. th Max 15m RS 232C Max 500m RS 422A 485 D sub 9 pin connector socket Pin 6 DC 5V output Max current 250mA Communication cable length Max 15m COM2 Compliant with EIA RS 232C 422A 485 D sub 9 pin connector socket At one point only one from RS 232C RS 422A and RS 485 can be designated to perform communications Communication cable length Ethernet communication specifications Max 15m RS 232C Max 500m RS 422A 485 Note The HMI of the NBLILI TWO1B has the Ethernet connection function Conformance standards Items Specifications Conforms to IEEE 802 3 Ethernet 10 100Base T Transmission medium 2 pair Cat 3 UTP 22 to 26AWG Cat 5 Cat 5e Cat 6 Transmission distance 100 m node to hub and hub to hub Connector 4 8 pin modular connector NB series Programmable Terminals Setup Manual V107 Appendices A 2 External Dimensions NB3Q TWOOB NB3Q TWO1B model 116 9 L v suoisuauiiq Z Y NB series Programmable Terminals Setup Manual V107 A 5 Appendices NB7W TWOOB NB7W TWO1B model A 6 NB series Programmable Terminals Setup Manual V107 Appendices A 3 RS 422A 485 Connections A 3 1 Grounding and Shielding of the Cables When performing communications using RS 422A 485 carry out the connec
96. the same CPU Unit are all unique Use a small screwdriver to set the rotary switches being careful not to damage them The factory setting is O 9 UNIT Setting range DS No Oto F Setting Node Numbers Use the node address switches to set the node address to a unique hexadecimal value Do not set it to the same value as any other Ethernet IP Unit or built in port on the same Ethernet IP network As long as it does not duplicate the address of any other Ethernet IP Unit or built in port the node address can be set from 01 to FE hex 1 to 254 decimal 9 NODE Setting range 4 01 to FE 1 to 254 decimal 9 YUN jo sBumes pue sed 5 2 S Set the upper digit using the left rotary switch and the lower digit using the right rotary switch The factory setting is 01 The Node ID of the dip switch here must be consistent with that of PLC in the Network Device Setting dialog box for the actual project created in the NB Designer Setting Local IP Addresses Set the local IP address with the CX Programmer or other computer support software Refer to the Ethernet IP Unit Operation Manual Cat No W465 for details on setting methods Ethernet Connectors This is the connector used to connect the twisted pair cable to the Ethernet Electrical Characteristics Conforms to IEEE802 3 standards Connector Layout RJ45 8 pin modular connector conforms to 150
97. tions shielding and grounding as follows Grounding wiring The NB Unit has a functional grounding terminal FG 1 Generally make the grounding according to Fig a e Connect the grounding terminals GR of the devices and the functional grounding terminal UA at only one point make a D type grounding Max grounding resistance 1009 e Short circuit the LG terminal and GR terminal of the PLC Usea cable with a minimum of 2 mm for the grounding cable For details about the connection methods refer to the related communication Unit manuals 2 As shown in Fig b when the NB Unit and noise source equipments such as motors and inverters etc are installed on the same panel do not ground the NB Unit s functional grounding terminal e Shielding of RS 422A 485 Cables Be sure to shield the RS 422A 485 cables Connect the grounding terminals GR of the devices and the functional grounding terminals UA at only one point make a D type grounding Max grounding resistance 1009 carry out a single end shielding according to Fig a If grounding is not done to the functional grounding terminal UA of the NB Unit shield both ends as Gcgy Vcci SH shown in Fig b Note In order to avoid malfunctions caused by interferences shield the cables properly seiqe Buipjerus pue v NB series Programmable Terminals Setup Manual V107 A 7 8
98. ual Cat No W462 CP1E SYSMAC CP Series CP1E CPU Unit Software User s Manual Cat No W480 2 36 NB series Programmable Terminals Setup Manual V107 2 Installing the NB Unit and Connecting Peripheral Devices Setting Local IP Addresses Use a Web browser to set the local IP address of the CP series Ethernet Option Board Refer to the following manuals for the setting procedures CP1H SYSMAC CP Series CP1H CPU Unit Operation Manual Cat No W450 CP1L SYSMAC CP Series CP1L CPU Unit Operation Manual Cat No W462 CP1E SYSMAC CP Series CP1E CPU Unit Software Users Manual Cat No W480 Ethernet Connector CP1W CIF41 This is the connector used to connect the twisted pair cable to the Ethernet e Electrical Characteristics Conform to the IEEE 802 3 standard Connector Layout RJ45 8 pin modular connector conforms to 1508877 i CP1L EL EM Setting Node Numbers Set the node number to a unique value from the CX Programmer or other Support Software Do not set it to the same value as any other Ethernet node on the same Ethernet network Refer to the following manuals for the setting procedures CP1L EL EM SYSMAC CP Series CP1L EL EM CPU Unit Operation Manual Cat No W516 uonoeuuo dAN SNI S Z Setting Local IP Addresses Set the local IP address from the CX Programmer or other Support Software for the CP1L EL EM series CPU Unit Refer to the following manuals for the setting
99. utput even if the input is momentarily interrupted for 10 ms Rated Power Supply Voltage DC 24 V Allowable range DC 20 4 27 6 V Do not perform a dielectric voltage test Making the connection by using terminal screws crimping on a twisted pair cable with a crimping range of 12 26 AWG and only 6 5 mm of insulation peel of the cable needs to be peeled off Tighten the terminal screws at a torque of between 0 3 and 0 5 Make sure the screws are properly tightened To prevent malfunctions caused by noise ground the Unit correctly Do not touch the packaging part of the circuit board with your bare hands Discharge any static electricity from your body before handling the board When using the No 6 pin of the serial communication COM1 connector for a voltage of DC 5V make sure the supply equipment s current capacity is below 250mA before using it The DC 5V voltage output of the NB unit is 5V 5 and the maximum current is 250 The serial communication port COM1 of NB3Q TWOOB and NB3Q TWO1B is unable to output the current Turn OFF the power supply before connecting or disconnecting cables Always keep the connector screws firmly tightened after the communication cable is connected The maximum tensile load for cables is 30 N Do not apply loads greater than this Confirm the safety of the system before turning ON or OFF the power supply or pressing the reset button The whole system may stop depending on how the po
100. wer supply is turned ON or OFF Turn ON OFF the power supply according to the specified procedure Reset by pressing the reset button or restart the power supply once the DIP switch settings are changed To ensure the system s safety make sure to incorporate a program that can confirm the normal functionality of the NB Unit before running the system Start actual system application only after sufficiently checking screen data macros and the operation of the program at the host side Do not press the touch panel with a force greater than 30 N Do not use hard or pointed objects to operate or scrub the screen otherwise the surface of the screen may be damaged Confirm the safety of the system before pressing the touch panel Signals from the touch switches may not be input if the touch switches are pressed consecutively at high speed Confirm each input before proceeding to the next one Do not accidentally press the touch panel when the backlight is not lit or when the display does not appear Make sure of the safety of the system before pressing the touch panel To use numeric input functions safely always make maximum and minimum limit settings Before initializing screen data confirm that existing data is backed up at the NB Designer NB series Programmable Terminals Setup Manual V107 When changing the password with the screen do not reset or turn OFF the power supply until writing is finished Failure to save the passwo
101. wing are some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor is it intended to imply that the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this manual Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product or any consequence thereof 10 NB series Programmable Terminals Setup Manual V107 Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice t
102. ype resistance type Operation force 0 5 0 8 N Press endurance min 1 000 000 times at 25 External specifications Specifications Items NB3Q NB5Q NB7W NB10W TWOOB TWO1B TWOOB TWO1B TWOOB TWO1B TWO1B USB Slave 1 port for screen data transmission with a PC Equivalent of USB 2 0 Full speed USB Host 1 port 1 port 1 port 1 port Equivalent Equivalent Equivalent Equivalent of USB2 0 of USB2 0 of USB 2 0 of USB 2 0 Full speed Full speed Full speed Full speed Programmer a software for making screen data and 7 mark means support Items Specifications NB3Q NB5Q NB7W NB10W Name Version TWOOB TWO1B TWOOB TWO1B TWOOB TWO1B TWO1B NB Designer version 1 0X Y Y NB Designer version 1 1X Y Y 2 NB Designer version 1 2 v v Y Y Y suoneoyroeds W z L v NB series Programmable Terminals Setup Manual V107 A 3 Appendices A 1 3 Communication Specifications Host Link communication specifications Items COM1 Specifications NB3Q NB5Q NB7W NB10W 00 01 00 TWO1B 00 01 TWO01B Compliant with EIA RS Compliant with EIA RS 232C 232C 422A 485 D sub 9 pin connector socket At one point only one from RS 232C RS 422A and RS 485 can be designated to perform communications Communication cable leng