Home
Manual (pdf 280k) - Schreder-CMS
Contents
1. sure the instrument and the cables are installed in a location where they will not get soaked Voltage Warning Power Supply e Make sure to check the power supply voltage and type AC DC before connecting the device to the power supply Connecting the device to other power supplies than specified will lead to damage and accidents J1034 UV A B E DETECTOR Manual 2 GENERAL DESCRIPTION This manual outlines the UV A UV B UV E UV AB and UV A UV E Broadband Detectors for measuring precise global UV irradiance for different spectral ranges The system provides a considerably improved measurement accuracy comparison to the traditional detectors The direct cosine error fz is typically less than 1 5 The detectors are flexible enough to be easily installed on every measurement site Detector base plates for individual alignment work and a shadow ring system J1033 SCHADOWRING make an effective meteorological system Technical Data UV E UV B UV A UV AB UV A UV E Relative spectral ISO response 17166 1999 265 315 310 400 280 400 See individual CIE S nm nm nm detectors 007 E 1998 Type Single band Dual band Cosine error 2 lt 1 5 Cosine Response lt 2 5 between 70 solar zenith angle Measure range 0 0 6 0 5 0 100 0 100 0 0 5W m W m W m W m W m 100W m2 Signal output 0 5 on request 0 2 5 V Temp
2. 2 0 eraann rannen nenna 2 GENERAL DESCRIPTION 3 DATA 3 PIN CONNECTION OF ALL UV 3 RELATIVE SPECTRAL 4 MOUNTING AND ALIGNMENT ccsssssssssssssosssesssseesessnsessnseessonseesenseeessnseessenseceenseeseeaessens 5 COMPONENTS PARTS REFERENCE sccsssssosssssosssssssecsestessestessusseeateseesteseuseeesateseasees 6 LIST OF ADDITIONAL 6 PREBERENCES 6 J1034 UV A B E DETECTOR Manual USER INFORMATION Thank you for using the UV broadband detector Make sure to read this instruction manual thoroughly and to understand the contents before starting to operate the instrument Keep this manual at safe and handy place for whenever it is needed For any questions please contact us at the CMS office given below CMS reserve the right to make changes to specifications without prior notice Warranty For warranty terms and conditions contact CMS or your distributor for further details CMS guarantees that the product delivered to customer has been verified checked and tested to ensure that the product m
3. Calibration of instruments for radiation measurements Measurement of radiation from UV to IR Software for special requirements The Austrian Calibration Measurement Software Company J1034 UV A B E DETECTOR USER S MANUAL CMS Ing Dr Schreder GmbH LofererstraBe 32 A 6322 Kirchbichl Tel 43 0 5332 77056 00 Fax 43 0 5332 77056 14 E Mail info schreder cms com Web www schreder cms com CMS Ing Dr Schreder GmbH J 1034 First printed January 2011 this revision October 2015 Copyright 2011 2016 by CMS Ing Dr Schreder GmbH All rights reserved Purchasers may make one copy of the software disk for backup purposes The software may not be copied or distributed in any other way No part of this manual may be reproduced or transmitted in any form or by any means electronic optical or mechanical including photocopying and recording or by any information storage and retrieval system without permission in writing from CMS Ing Dr Schreder GmbH TABLE OF CONTENTS TABLE OR CONTENTS TION ce ace 1 5 1 CONTACT INFORMATION 1 SAFETY INFORMATION csccssssssssssssssosseesssnseesssseecsenseessnseeseesuesesenseseesueessanssessueessonseessaess 2 WARNING 9 2 VOLTAGE
4. 4 SHADOWRING 100229 Circlevel1 Circular spirit level References 1 WMO GAW Report No 141 Report of the LAP COST WMO Intercomparison of Erythemal Radiometers Thessaloniki Greece 1999 WMO TD No 1051 2 WMO GAW Report No 146 Quality Assurance in Monitoring Solar Ultraviolet Radiation the State of the Art WMO TD No 1180 3 WMO GAW Report No 164 Instruments to measure Ultraviolet Radiation Part 2 Broadband Instruments Measuring Erythemally Weighted Solar Radiation WMO TD No 1289 4 ISO 17166 1999 CIE S 007 E 1998 Erythema reference action spectrum and standard erythema dose 5 Schreder J J Grdbner Los and Blumthaler 2004 Intercomparison of monochromatic source facilities for the determination of the relative spectral response of erythemal broadband filter radiometers Optics Letters 29 13 6 G H lse J Gr bner A Bais Blumthaler Disterhoft Johnsen Lantz Meleti J Schreder J M Vilaplana Guerro L Ylianttila Intercomparison of erythemal broadband radiometers calibrated by seven UV calibration facilities in Europe and USA Atmos Chem Phys 8 4865 4875 2008 http www atmos chem phys net 8 4865 2008 acp 8 4865 2008 html J1034 UV A B E DETECTOR Manual 6
5. eets the appropriate specifications The product warranty is valid only if the product has been installed and used according to the directives provided in this instruction manual CMS shall in no event be liable for incidental or consequential damages arising from the faulty and incorrect use of the product In case of any manufacturing defect the product will be repaired or replaced under warranty However the warranty does not apply if e Any modification or repair was done by any person or organization other than CMS service personnel e The damage or defect is caused by not respecting the instructions of use as given on the product brochure or the instruction manual Contact Information CMS Ing Dr Schreder GmbH LofererstraBe 32 6322 Kirchbichl Austria Tel 43 0 5332 77056 00 Fax 43 0 5332 77056 14 E Mail info schreder cms com Web www schreder cms com J1034 UV A B E DETECTOR Manual 1 SAFETY INFORMATION This product is designed and manufactured under the consideration of the safety precautions Please make sure to read and understand this instruction manual thoroughly in order to be able to operate the instrument safely and in the correct manner Warning Caution Setup e The installation base should have enough load capacity for the instrument to be mounted Fix the equipment securely Otherwise the instrument may drop due to gale or earthquake which may lead to unexpected accidents
6. erature range 40 C 60 C Temp coefficient 0 1 K Power Supply 9 24 0 75 Time switch lt 1 Linearity lt 1 Housing Anodised aluminium Quartz glass dome Dimension 80 mm diameter D x 88mm height H Leveling plate 115 mm D x 88mm H Weight lt 1kg 8 4 1 Vec white 1 Vcc white l a 2 2 GND brown Pin connection e 3 N C Gray 2 GND brown 1 2 4 output UV yellow 3 5 housing sreen 4 UV Ane 5 Housing Screen Pin connection of all UV detectors 1 Vcc white 9 24V 0 75mA 2 GND brown Ground for power supply and signal output 3 N C Output UV gray not connected single band UV E dual band output 4 Output UV yellow UV B UV A UV E UV AB output UV A dual band output 5 Housing J1034 UV A B E DETECTOR Manual 3 Relative Spectral Response RELATIVE SPECTRAL RESPONSE 4 10 260 280 300 320 340 360 380 400 WAVELENGTH nm Figure 1 Relative Spectral Response of the single band detectors Erythemal weighting function ERY defined ISO 17166 1999 CIE S 007 E 1998 10 10 10 10 RELATIVE SPECTRAL RESPONSE 4 10 260 280 300 320 340 360 380 400 WAVELENGTH nm Figure 2 Relative Spectral Response of the dual band detector Erythemal weighting function ERY defined ISO 17166 1999 CIE S 007 E 1998 J1034 UV A B E DETECTOR Manual 4 MOUNTING AND ALIGNMENT The Detector should be aligned
7. with the help of the spirit level and the montage screw and fixing screw The sprit level is mounted inside the levelling plate The following picture illustrates the components to align the detector correctly To avoid measurement errors the detector should be carefully levelled in the horizontal plane The additional available Detectorbase 105303 allows a robust and quick alignment of the detector do individual grounds Use the tilting screws to align the detector and control the correct settings with the help of the spirit level After that use the montage screws to fix the detector to the ground TILTING SCREW MONTAGE SCREW 105103 This part fits ideally to qhe Figure 3 UV gear on D Detectorbase Art No J1033 Shadowring which can be seen on the next page J1034 UV A B E DETECTOR Manual 5 COMPONENTS PARTS REFERENCE List of additional parts Order No Parts Description 103401 UV A UV A radiometer 103404 UV B UV B radiometer 103406 UV E UV E radiometer erythemally weighted 103410 UV AB UV AB radiometer 103411 UV A UV E UV A and UV E radiometer dual band 103402 UV 10m 10 m weatherproof Cable connection for UV radiometers 105102 Power 12V Plug in power supply 12VDC 2A 105103 DETECTORBASE Detector base to hold detector in selected place Shadow ring for manually alignment To measure diffuse part of J1033 solar radiation 10330
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung Freak Kompaktbike Intellinet 19" Server Cabinet 42U La route 113 La route 113 InFocus IN3102 User's Manual StarTech.com SAT3510BUVEU storage enclosure Cooper Lighting Tahoe 504 User's Manual 広報誌(2015年1月) - 日本科学技術振興財団 Bedienungsanleitung - Amazon Web Services Copyright © All rights reserved.
Failed to retrieve file