1. User Manual Ruby 8 ahead of the curve Ruby 8 Alternating Micro Low Air Loss Pressure Relief System User Manual Distributed by Quart Healthcare Inc www quarthealthcare com User Manual Ruby 8 ahead of the curve e e kS kS kS Warning Connect the Master Control unit to a proper power source Do not use the system in the presence of any flammable gases such as Anesthetic Agents Keep the pump and mattress away from sources of liquid and open flames Keep mattress away from sharp objects The device is not AP APG protected Keep mattress system away from heating devices Caution Consult clinical instructor before use of mattress Support surfaces should always be used in conjunction with a care plan that includes the turning repositioning of the patient over a 24 hour period The control unit should only be repaired by an authorized distributor Do not drop the control unit or store it in direct sunlight or extreme cold conditions Product Description The Ruby 8 system is a unique and innovative specialized mattress replacement unit It features a patented 8 shape twin cell design whereby the bottom half of the cell is always inflated and the top half is free to alternate The system utilizes micro low air loss technology with a low rate of flow The advanced 3 1 alternating function also provides active prevention for pressure relief especially for thos
2. bes allow smooth airflow Is an air tube kinked Is there any air leakage from the air cells Is there any air leakage from air tube between mattress and control unit Has the air tube connector been connected properly 1 Use power regulator 2 Adjust the air tubes to enable smooth air flow 3 Replace with new air cells 4 Replace with new air tubes 5 Re connect the air tubes The Control Unit is not working 1 Check the power cord and the power voltage 2 Check the fuse 1 Use a power regulator 2 Replace with a new fuse Some air cells have abnormal low air pressure while the air pressure for other air cells is normal 1 2 Is the connection between air cells and the manifold kinked Is there any air leakage from the air cells 1 Adjust the connection between cells and manifold 2 Replace with a new air cell User Manual Ruby 8 ahead of the curve 5 Warranty Quart Healthcare Inc guarantees that this equipment is free from defects in materials and workmanship Our obligation under this warranty is limited to the repair of equipment returned to the place of purchase within 24 months of delivery date We agree to service adjust any equipment returned and to replace or repair any part that is proven to be a warranty defect at no charge This warranty excludes equipment damage through shipping tampering improper maintenance carelessness accident negligen
3. ce or misuse or products that have been altered repaired or dismantled other than with the manufacture s written authorization and by its approved procedures and by properly qualified technicians In no event shall Quart Healthcare Inc be liable for any direct indirect or consequential damages or losses resulting from the use of equipment
4. e in acute care and long term care settings the cells inflate and deflate in a 3 1 cycle meaning 2 3rds of the body is always supported at any one time The soft firm adjustment allows the patient to adjust the firmness or softness of the surface for optimal comfort The surface also has 2 inches of enclosed convoluted foam to provide extra protection and comfort for the patient Control Unit Features pump Alternating time is set at a non adjustable 7 minute cycle time The caregiver can select the Static Function stopping the alternating function and providing only micro low air loss therapy Power failures produce an audio alarm for added safety The alarm can be disabled by pushing the ALARM RESET Button on the front panel Ser URE ALARM RESET Double insulation provides near silent operation The foot board mounting rack provides convenient placement for the control unit on the bed User Manual Ruby 8 ahead of the curve Master Control Unit Model No FC QHI0059 Size cm 32 L x12 W x23 H Weight Kg 3 Phase Time min 5 30 Rated Voltage 100 120 volt Max Current 0 2 Amp Rated Frequency 60 Hz Protection Type Class Il Type BF Mode of Operation Continuous Safety Standard UL CSA Mattress Replacement Features Individual air cushion design for maximum pressure distribution Air cells are vented to provide micro air loss therapy Centre air cells are ve
5. nted to provide micro low air loss therapy Model No FM QHI0002 Size cm 89 W x203 L x24 H Weight Kg 20 Kg Cells Material Nylon w PU backing Cover Type Zipper cover with removable foam base Cover Material Nylon woven fabric w PU coating finish Base Material Woven Polyester fabric w PVC backing Cells Number 18 cells Optional foot rest copes with a variety of heights and prevents patient sliding Alternating System 2 Instructions for Proper Use i Remove the existing mattress from the bed frame ii Replace the standard mattress with mattress replacement system orient mattress so that the air tube is at the foot of the bed iii Secure straps beneath the mattress to the bed frame iv Hang the control unit on the foot board of the bed frame v Attach the air tube connectors to the socket on the left panel of the control unit vi Verify that air hoses are not kinked under the mattress vii Attach cover to mattress viii Plug in the control unit and turn on the master power switch on the front panel ix After the mattress is fully inflated the caregiver can transfer the patient to the mattress User Manual Ruby 8 ahead of the curve Static Function Push the ALTERNATE STATIC switch to STATIC mode and adjust the comfort control by turning the pressure control knob On this mode the system provides only low air loss therapy Perform a hand check by placing hand under the patient s but
6. tocks between the cells and foam The patient should have at least 4 cm of clearance between the buttocks and the bottom of the mattress Dynamic Function Push the ALTERNATE STATIC switch to ALTERNATE mode to enable the 3 1 alternating function CPR Deflation For quick mattress deflation disconnect the hose connector from the controller and release the CPR quick deflation valve Cleaning The mattress should be cleaned on the bed weekly using a damp soft cloth and mild detergent If the top or bottom cover becomes severely soiled remove clean as follows and replace with a clean cover Covers can be washed and thermally disinfected in a washing machine Never use phenol based cleaning solutions Industrial cleaning Break wash cold 10 min Main wash 60C 6 min Main wash 70C 10 min Extraction 2 min 3 cold rinses Extraction 5 min Domestic cleaning Pre wash cold Main wash 70C 10 min Extraction 2 min Cold rinses Extraction 5 min TUMBLE DRYING OR TUNNEL DRYING IS NOT RECOMMENDED Mattress cells can be wiped with a solution of sodium hypochlorite 1000ppm or any other non phenolic germicidal solution The control unit should also be cleaned weekly using a damp soft cloth and mild detergent Switch off the electrical supply to the pump and disconnect the power cord from the main supply before cleaning and inspection The Pump The casing of the pump is manufactured from ABS plastic If soiled it can be wiped down with a sodium h
7. ypochlorite solution to dilution of 1000ppm or any EPA approved hospital grade disinfectant Do not use phenol based cleaning solutions User Manual Ruby 8 EA Overs ahead of the curve 3 Storage and Care Control Unit Check the power cord and plug for abrasions and excessive wear Plug in the unit and verify air flow from the hose connection ports Place in plastic bag for storage Mattress Replacement System Check the air manifold for kinks or breaks Replace if necessary Twist open the CPR plug at the head of the mattress and disconnect the air feed tubes All of the air will be expelled Starting at the head of the mattress roll towards the foot of the bed Use the base mounted straps to secure Place the system in a plastic bag for storage It is recommended that the following guidelines are used whenever the system is being stored or transported to another location Temperature limitations Relative humidity 10C to 40C 30 to 95 4 Maintenance and Troubleshooting No daily maintenance is required This equipment should only be serviced by authorized technical personnel In case of minor problems refer to the following Symptom Inspection Procedure Possible Solution The air is flowing out from the control unit but the mattress is not inflating Is the power source correct Improper voltage may cause the pump to function abnormally and damage the control unit Do the air tu