Home
PowerWalker VI 1000-2000 Manual
Contents
1. Power monitoring software performs the monitoring and controlling functions This software displays the status and diagnostic symptoms on the monitor In case of the power failure it provides the auto shutdown for the computer If you download the software from Internet please key the serial number 726T25 4791 2N39546 smart Power Yeri 0 S 8 s 6 5 e 5 0 o e COM Pot Record Alarm Broadcast E Mail Shutdown Self Test Sehedule Remote Language Help Exit Search Setting Setting Sitent Setting Setting Setting Setting UPS UPS Status Agentin Computer Port Name UPS Model Location ics2000 COM1 LINE INT Normal Local jes200 USB LINE INT Normal 6 Remote z jno connection lez Remote I ino connection iz Normal On Battery 00 00 00 Model Yoltage l Voltage LINE INT 216 0 Y 217 0 Voltage 13 8 Y O O Standard 12 0 Y 25 Capacity 100 Com Port COM1 Frequency 59 9 Hz Load 21 Temperature 38 0 C 7 TECHNICAL SPEICIFICATION 8 TROUBLE SHOOTING MODEL LOMAS e Poner talker To call for service please have the model serial number and description of 1000 1400 2000 the problem available CAPACITY a 1000VA 600W 1400VA 840W 2000VA 1080W PROBLEM POSSIBLE CAUSE SOLUTION voles Rame Ilo 85 140VAC or 162 290VAC 170 280VAC NO LIGHT UPS 1 The power switch is in
2. l Press power switch to turn on Frequency 45 65 Hz Auto Sensing OFF or not pressed OUTPUT Voltage Batt 110 120 220 230 240VAC 10 2 The voltage for battery is 2 Re charge the UPS at least 8 pd ee 50Hz or 60Hz 1 Hz Mode Output Waveform Modified Sinewave Battery mode batt ll fo ice Battery Type 12V7Ahx2 12V9 Abhx2 i O attery or call for service dany mi N Aomine ine DE mimites 4 Power Connection looses 4 Check the input power and replug 15 monitor 1t again 8 hours to 90 after complete discharge TRANSFER UZZER BEEPS 1 Overload of the UPS 1 Remove the noncritical load or call CONTINUOUSLY for service INDICATOR ACMod 1 green LED lighting ia 2 to 5 green LEDs lighting indicating load level l 1 green LED flahsing ACKUP TIME IS _ 1 Battery failure 1 Replace with same type of battery 2 to 5 green LEDs lighting indicating battery capacity SHORT OR ALWAYS Breall S TT Red LED lighting AUDIBLE Backup Mode Sounding every 10 seconds 2 AC fuse may be burnout 2 Replace fuse or call for service ALARM Sounding every second Overload Soundingevery 0 5 second si Sounding every 0 5 second 3 Battery is not fully charged B Re charge the UPS at least 8 Fault Continuously sounding sid Continuously sounding PROTECTION Full Protection Full Protection Discharge overcharge and overload protection 4 Check the input power and replug PHYSICAL Dimension 368 3 x 140 2 x 180 4 4 Po
3. Do not block off ventilation openings in the UPS system s housing Do not place the UPS near water or in environments of excessive humidity Remove personal metal items such as rings bracelets necklaces and watches when working with batteries Batteries can produce a short circuit current high enough to make metal melt and could cause severe burns When replacing batteries replace with the same number of the sealed lead acid batteries 3 OVERVIEW Front Panel ON OFF Button Press the On Off button to turn on or off Fault LED The Fault LED will be on and beeps continuously when the UPS is at faulty condition On Line Indicator Load Level LEDs Backup Indicator Battery Capacity LEDs On Line Indicator The green light indicator illuminates when the input line voltage is normal Backup Indicator The green light indicator flashes when the internal battery is being used Back Panel 1000VA 1400 VA 2000VA Battery Power Supplied Receptacle The power supplied receptacles are used for battery to power up your equipments while AC is failure AC Input Power Receptacle The power receptacle is used to plug in the power cord that provides power to the UPS Circuit Breaker The circuit breaker is used to protect your equipment against the event of short circuit or system overload Telephone Fax Modem Surge Suppression Port This surge suppression port is used to protect the telephone or modem li
4. POWERWALKER Uninterruptible Power Supply Line Interactive VI 1000 1400 2000 User s Manual 28 2PW 0000003 Thank you for purchasing PowerWalker UPS Safety information and operating instructions are included in this manual To ensure the correct use of the UPS please read this manual thoroughly before operate it And save this manual properly 1 INTRODUCTION PowerWalker VI series is an intelligent and compact line interactive UPS which is designed to protect your personal computer or sensitive electronic equipments The UPS is equipped with advanced microprocessor controlled and included built in boost and buck AVR to prevent the equipment damage and data loss The UPS can be automatically started up without AC power supplied The special feature is that hot swappable user replaceable battery is easy to replace or change in case of battery In addition this UPS provides advanced modem or telephone line surge protection and the small footprint tower design can be placed on your desk space or floor It is equipped with many features that allow any attached equipment to operate longer and more reliability PowerWalker VI series protects computer systems servers storage systems and network peripherals from blackouts power surges and spikes Description of Features Compact size and light weight design which can be placed on the cabinet or desk Utilized microprocessor control to maximize the reliability and efficien
5. cy Equipped with built in boost and buck AVR to prevent the equipment damage and data loss Cold start capability enables UPS can be automatically turned on in battery mode during blackout Include discharge overcharge and overload protection Provides advanced telephone fax or modem surge suppression protection Built in RS 232 with connecting intelligent monitoring software User replaceable batteries allow on site battery replacement USB available optional 2 SAFETY REQUIREMENTS Please save this manual properly This manual includes important safety information Please read it carefully and thoroughly before operating the UPS Comply with all the warnings and operating instructions on the unit and in the manual strictly To reduce the risk of electric shock the user must disconnect the UPS from the mains supply before installing any cable To reduce the risk of electric shock Do not attempt to disassemble the UPS This UPS is no user serviceable parts inside Please contact qualified service personnel to do any service Do not connect with laser printers cosmetic appliances medical equipments microwave ovens vacuum cleaners or heavy duty hardware to UPS because they take too much power Do not dispose of batteries in a fire They may explore Do not open or mutilate batteries They contain an electrolyte that is toxic and harmful to the skin and eyes Do not allow liquid or foreign object to enter inside of UPS
6. ect the interface cable from your computer to the output receptacles on the back panel of the UPS Connect the Telephone Modem Line Connect a single telephone cable into the IN telephone modem surge suppression port on the back of the UPS Require another length of telephone cable to connect into OUT telephone modem port on the back of UPS to the modem input socket Connect the RS 232 USB Communication Port Connect a RS 232 serial cable USB cable from RS 232 USB communication port on the back of the UPS to Computer Systems that will be auto detected Green Mode Function 1000VA only Green mode enables to save the power if none of the load is connecting DC Start Function When the power is not supplied from AC utility DC start function will be started up automatically Switch Off Press OFF button to turn off the UPS after use or test optional 5 BATTERY REPLACEMENT Before battery replacement please ensure the power switch on the UPS is in OFF position Step 1 Remove the front panel of the UPS Step 3 Disconnect the battery cable and pull the battery out onto a flat area Step 4 Slide the new battery and reconnect the battery cable by screwing up the battery retaining battery bracket Step 5 Close and reinstall the front panel of the UPS 6 MONITORING SOFTWARE After the UPS has been installed you must install the software Smart Power that came packaged with your UPS Smart
7. ne while connecting the INTERNET service RS 232 Communication Port This communication port is used to communicate with a computer or modem and support the operating systems USB Communication Port optional This USB communication port is used by downloaded software 4 INSTALLATION Before the installation please ensure the power switch on the UPS is in OFF position and the voltage of the AC utility source corresponds to the identification label on the rear panel Inspection Inspect the UPS upon the receipt If there is any damage please report it to dealer immediately The packaging is used recyclable material please save it for reuse or dispose of it properly Placement Install the UPS in a protected area within a temperature range from 0 40 C and relative humidity of 0 90 without condensing And place the UPS in a location free from excessive dust and chemical fumes Please notice that the UPS voltage and power rating match to the line voltage and load requirements Connection Connect the power cord to the utility power to power up the UPS Press ON button to turn on the UPS the green light indicator illuminates that AC utility voltage is present Charge the Battery Charge the battery automatically when UPS is connected to utility power Some It is recommended that the battery will be re charged for at least charges may be lost 8 hours before using the UPS 10 Connect the Computer Conn
8. wer Connection loses DxWxH mm l it again ENVIRONMENT Less than 45dB INTERFACE Smart RS 232 Windows family Sun Solaris IBM Aix Compaq True64 UnixWare FreeBSD HP UX Linux and MAC USB Port Windows 98 2000 ME XP Option 3 Battery failure 3 Replace with the same type of