Home
Punch User Manual
Contents
1. flow sc series Cashflow SC83 Installation amp Operation Manual Cds mel Mars Inc 2004 Printed in USA MEI is a trademark of Mars Inc Information is subject to change without notice MEI has made every effort to ensure that the information in this document is accurate However we cannot be held responsible for any errors or omissions Technical Support 1 800 345 8172 CASHFLOW SC83 Page 1 www meiglobal com Part 252055088 R1 TABLE OF CONTENTS OVERVIEW teure Eege 3 SL ri l IN UD CE eis ccecencevstcyoscececsesssvesesececacdsencootenscopssesssuecuecssvssvecussurscassseseecousteseevsz s 3 De NEE 4 5 Main Components of the SC83 Bill Acceptor 6 Power FR e VE E TE saseccecesnces ossssicevascasssussuosesescxceveeesstseeeteacesseuecsseresetessoseeessecasv eases 6 INSTALLATION AND REMOVAL OF COMPONENTS Installing the Chassis 7 Inserting and Removing the Acceptor Module 8 Installing a Bill Entry Guide 9 lostalhine the CashDOX eet 10 Removing the Cashbosx 10 Installing Locks on the Cashbosx 11 UPDA
2. When installing or removing the prom observe all ESD precautions to prevent damage Technical Support 1 800 345 8172 CASHFLOW SC83 Page 3 www meiglobal com Part 252055088 R1 OVERVIEW Features Chassis Cashbox Technical Support 1 800 345 8172 CASHFLOW SC83 Page 4 www meiglobal com Part 252055088 R1 OVERVIEW Features GI LIGHT BAR s LENSED RECEIVER CUSTOM BAR CODE READER L 100 MHZ DSP PROCESSOR EARLY BILL PICK UP SMOOTH SEALED BILL PATH DIRECT ROLLER DRIVE RIDGES MATE WITH ACCEPTOR INTERNAL DIRECT ROLLER DRIVE ELEVATOR Un SHORT BILL PATH DURABLE WELDED PLASTIC EXTERIOR RECESSED PLASTIC GEARS DUAL LOCK CAPABILITY COMMON ACCEPTOR MODULES PC STYLE EDGE CONNECTOR INTERFACE CARDS ACCEPTOR RELEASE LATCH BILL PATH RELEASE DISPUTE RESOLUTION WINDOW BILL ENTRY GUIDE amp POWER MOUNTING CONFIGURATION BUTTON NOT USED ON SC83 SERIES Ei DIAGNOSTIC LEDS SEE PAGE 18 FOR DETAILS USB SERVICE PORT SEE PAGE 12 AND FIGURE 2 FOR DETAILS ACCEPTOR USER INTERFACE FLEXIBLE HANDLE PASSIVE CASHBOX LATCHES Technical Support 1 800 345 8172 CASHFLOW SC83 Page 5 www meiglobal com Part 252055088 R1 OVERVIEW Main Components of the Cashflow SC83 Bill Acceptor The SC83 consists of three main components Cashbox LRC Acceptor Module Chassis The Acceptor Module and Cashbox are interchangeable with other identical SC83 models Bill Entry Guides for the SC83 Not all b
3. Installing Locks On The Cashbox The cashbox may be fitted with either one or two security locks The product is designed to accept locks from a range of manufacturers including Medeco Kaba Abloy VSR Miwa Duo Standard 5 8 and 1 1 8 formats are supported There is a significant variety of lock designs and spacer washers may be required for some lock types Two locking hasps are shipped with every cashbox Contact MEI for cashbox lock specifications Locks vary greatly in price security keying policies etc The customer is responsible for selecting a lock with performance that is fit for the intended purpose MEI does not test or endorse any specific brand of lock for security characteristics When only one lock is used the remaining blank hole does not give access to the contents of the cashbox However some jurisdictions may require a blanking plug Contact MEI for assistance in obtaining a suitable plug When two locks are installed they must rotate in opposite directions See the figure below Bottom View of Cashbox Technical Support 1 800 345 8172 CASHFLOW SC83 Page 11 www meiglobal com Part 252055088 R1 UPDATING SOFTWARE There are two ways of updating the software of a Cashflow SC83 bill acceptor 1 Via a hand held device called the cashflow Portable Programming Module PPM 2 By replacing the programmed PROM Chip Change Portable Programming Module CONNECTING THE PPM TO THE CASHFLOW SC83 1
4. Locate the two USB ports located on the top of the Cashflow Programming Module See fig 1 below 2 Plug the type A end of your USB cable to the USB type A port of the PPM Plug the type B end of the same USB cable into the USB type B port of the Cashflow SC83 see fig 2 Type A USB port Type B USB port download button fig 1 PPM fig 2 Note Once you install a PROM chip the bill acceptor can no longer be programmed by the Programming module PPM Once a prom is installed the bill acceptor disables the ability for the programing module PPM to communicate with the bill acceptor Future software changes will have to be made by replacing the PROM chip change only Technical Support 1 800 345 8172 CASHFLOW SC83 Page 12 www meiglobal com Part 252055088 R1 UPDATING SOFTWARE PPM DOWNLOADING PROCEDURE 1 After connecting the PPM to the Cashflow SC83 via the USB interface refer to previous page illustration you are now ready to start the download procedure 2 Press the square download button located on the front of the PPM see fig 2 on previous page 3 When downloading the PPM will have a solid green and a flashing red LED indicating the PPM is busy Once the dowload is complete the LED on the PPM will change to solid green and a solid red indicating a successful download The bill acceptor will perform a run and stack and the the LEDs on the PPM will turn off 4 Disconnect the USB harness from the Cashflow
5. slide it back and remove it 5 You may now remove the PROM using a PLC puller Technical Support 1 800 345 8172 CASHFLOW SC83 Page 14 www meiglobal com Part 252055088 R1 UPDATING SOFTWARE Replacing the programmed prom Continued Replacing the yellow cover N ote To install the yellow cover the acceptor module must remain open 6 To re install the yellow cover align the cover back to the position shown below 7 Once in position move the yellow cover forward as if you were opening the acceptor module untill the cover locks into place 8 Close the acceptor module and re install it into the chassis 9 If the power is on the unit will power up and perform a run and stack Technical Support 1 800 345 8172 CASHFLOW SC83 Page 15 www meiglobal com Part 252055088 R1 HARNESSING AND CONNECTORS EBDS Interface Pin Out N ote Some SC 83 units will come with connectors that are OE M Speatic Please refer to the host machine manual for pinout and connector information Cashflow SC83 bill acceptors with an EBDS Interface will have a cable with a 12 Pin Connector Latch Pin 12 Pin Chassis Docking Station Connector End View SC 8307 RS232 E BDS version ConnectorPin Wire Color Signal P2 pin 1 White Cassette present 10 2 Gray Bezel LED drive 2 3 Red 4 Yellow Out of Service 11 5 Blue G round D amp H 6 Pink RS232 EBDSRXD L 7 Black Power 2 2 amp B 8 Purple LE
6. Bill Entry Guide Acceptor Module e Once the bill entry guide is aligned properly remember to go back and tighten the screws on the chassis refer back to Chassis installation instructions e To remove a bill entry guide slide a flat head screwdriver between the bill entry guide and the acceptor module as shown in the diagram on the right Technical Support 1 800 345 8172 CASHFLOW SC83 Page 9 www meiglobal com Part 252055088 R1 INSTALLATION Installing The Cashbox e With the chassis mounted securely to the machine you may now insert the cashbox into the chassis The cashbox has slots on both sides that will guide it into the chassis When you insert the cashbox you will feel some resistance from the two springs inside the chassis Make sure to insert the cashbox all the way in so that the rear of the cashbox is flush against the chassis wall Removing the Cashbox e When the bill acceptor is installed in a machine you just need to grab the yellow strap on the cashbox and pull firmly to release it The cashbox does not lock on to the Chassis e To remove the cashbox when the unit is not installed grab on to the yellow handle and place your thumb on the chassis were indicated in this diagram Placing your thumb at this location will give you sufficient leverage to remove the cashbox Place Thumb Here Technical Support 1 800 345 8172 CASHFLOW SC83 Page 10 www meiglobal com Part 252055088 R1 INSTALLATION
7. SC83 once the LEDs on the PPM are off 5 Once dowload is complete the Cashflow SC83 s diagnostic LED s will flash five times green continuously until communication between the bill acceptor and the machine is re established Diagnostic Codes For The PPM Led Codes solid green PPM on solid green flashing red PPM busy solid green solid red upgrade complete Error Codes flashing green battery low alternating flashing green and red wrong product connected solid green flashing red 1 time bill reader error solid green flashing red 2 times PPM error solid green flashing red 3 times program error Technical Support 1 800 345 8172 CASHFLOW SC83 Page 13 www meiglobal com Part 252055088 R1 UPDATING SOFTWARE Replacing the programmed PROM Chip Change Note Once you remove the programmed PRO M perform a chip change the bill acceptor can no longer be programmed by the Programming module PPM Once a PRO M is inserted or removed the bill acceptor disables the ability for the programing module PPM to communicate with the bill acceptor Future software changes can only be made by replacing the PROM chip change 1 Remove the acceptor module from the chassis Instructions on how to remove it are on page 8 2 Open the acceptor module 3 Release the yellow cover from the left and the ia front comer of the acceptor module Lift the clip on both sides 4 Once the yellow cover is released in the front
8. these modules refer to the CASHFLOW SC83 Operation amp Maintenance Manual What purpose do the Cash Box arrows serve Arrows highlight a cassettes position upright or upside down Arrows provide a visual aid to Soft count crews who frequently arrange cassettes by position to signal that they are full or empty What is the purpose of the USB and 8 pin connectors on the front of the Acceptor Module The USB connector is used to connect a PPM Portable Programming Module to a CASHFLOW SC83 unit The PPM is used to download new software into a CASHFLOW SC83 The pupose of the 8 pin connector is to provide appropriate drive voltage and enable signals in some lighted BEG Bill Entry Guide that get installed on the bill acceptor Some BEG do not plug into the bill acceptor they plug directly to the machine How is software updated in CASHFLOW SC83 Flash units and PROM units in the field Flash versions of CASHFLOW SC83 units can be updated in the field by using a PPM Portable Programming Module PROM versions of CASHFLOW SC83 units can be updated by replacing the PROM Chip that is located under the yellow Acceptor Latch on the Acceptor What is a PPM Portable Programming Module and how does it work A PPM is a yellow handheld device that is programmed by MEI and is used to download software into a CASHFLOW SC83 Flash units The PPM consists of a yellow button a red and green LED and 2 USB connectors To use a PPM f
9. 088 R1 FREQUENTLY ASKED QUESTIONS 9 10 11 Can a CASHFLOW SC83 unit be calibrated in the Field A CASHFLOW SC83 unit can not be calibrated in the field The CASHFLOW SC83 is designed not require field calibration Calibration is only required after certain repairs that are done to aCASHFLOW SC83 unit Therefore only an approved CASHFLOW SC83 Service Center are trained to calibrate a CASHFLOW SC83 unit What are the differences among model Zei SC 8300 is a vanilla unit that has no recognition or interface software installed in it It also does not have a harness attached to the chassis SC 8302 is a Flash unit made to interface to IGT s Netplex machines It uses the IGT ID 024 interface SC 8302 P isa PROM unit made to interface to IGT s Netplex machines It uses the IGT ID 024 interface SC 8304 is a Flash unit made to interface to various machines It uses MEI Opto Isolated EBDS Interface SC 8304 P is a Prom unit made to interface to various machines It uses MEI Opto Isolated EBDS Interface SC 8307 is a Flash unit made to interface to various machines It uses MEI RS 232 EBDS Interfaces SC 8307 P US is a PROM unit made to interface to various machines It uses MEI RS 232 EBDS Interfaces What are the differences among interfaces MEI EBDS Extended Bi Directional Serial Protocol is a proprietary MEI protocol specification used to accomplish two way serial communication between the bill a
10. 2 to another SC8302 Consider the machine denomination and verify that the correct bills are enabled disabled and that any bezel place cards display proper denominations Contact our technician prior to swapping non like model i e SC8304 to SC8302 Not all non like models can be swapped 21 Who can contact for service on aCASHFLOW SC83 MEI Technical Support 1301 Wilson Drive West Chester PA 19380 610 430 2500 MEI Toll Free Us amp Canada 1 800 345 8172 Technical Support 1 800 345 8172 CASHFLOW SC83 Page 23 www meiglobal com Part 252055088 R1 DRAWINGS 1 457 1 496 2X 37 0 2X 38 0 PETER 4X 3 75 148 t ACCESSORY MOUNTING HOLES d j i MAX DEPTH 7 5 295 geit WM D eee La L d pom Ll A HE 3 740 E 2X 95 0 _ 374 SCH mg L Eee 2X 2 76 108 SUITABLE FOR 4 PLASTITE Id SCREW MAX DEPTH 8 0 314 l oe ___ fi E T E A eg ek Ce 1 UR H LUGS FOR INTERFACE Se a rt _ gp CABLE STRAIN RELIEF 84 6 3 307 CASHFLOW 83 i 87 1 2 642 CASHFLOW BB Ll 157 l L SOSLOTFOR
11. D Supply 9 9 Brown e 10 Orange _ H Green Power 1 amp A D Tan RS232 EBDSTXD K NOTES RXD refers to input to Bill Acceptor TX D is an output 2 Pins 7 and 5 are tied with a loop of wire in back of the 12pin connector SC 8304 Opto Isolated EBDS version ConnectorPin Wire Color Signal P2 pin 1 White AuxA 14 2 Gray LED 1 3 Red V opt 7 4 Yellow V ret 3 5 Blue G round D amp H 6 Pink Isolated Reset 6 7 Black Aux B 15 8 Purple LED 8 9 Brown Isolated TX D 4 10 Orange Isolated RX D 3 H Green Power 1 amp A D Tan Power 2 amp B NOTES RXD refers to input to Bill Acceptor TX D is an output Pins 12 and 5 are tied with a loop of wire in back of the 12pin connector Technical Support 1 800 345 8172 www meiglobal com CASHFLOW SC83 Page 16 Part 252055088 R1 Non Committed Contacts Depending on the desired interface the SC83X X may be supplied with one or two sets of non committed contact leads for OEM use The contacts are rated at 125VAC 54 MPs Maximum Wire connections are as follows OEM SW1 or2 COM White OEM SW1 or2 NC Red OEM SW1or2 NO Maintenance Periodic maintenance can improve the performance and extend the working life of a bill accep tor Additional attention may be required if the bill acceptor becomes inoperable due to a jammed object or acceptance rates fall below normal Cleaning the Acceptor Module Note You must remove the Acceptor Module from the chassis to open the front senso
12. GPTIONAL rr ee ES EXTERNAL CASSETTE LOCK 2 SIDES LIGSPINTYEREKEE h CABLE MAY EXIT tt HORIZONTALLY n 6X MOUNTING HOLES OR VERTICALLY d M4 THREAD MAX DEPTH 6 0 i L 1 969 0 50 6 ul i SN _ N Mi I 2 992 i 76 6 11 944 10 984 303 3 279 0 10 121 J BILL PATH Gel MOUNTING HOLES 4X 64 0 THROUGH 4 0 MAX SCREW HEAD 7 0 x 2 5 THICK H I 7 283 KR 185 0 2 000 50 1 181 300 s i f b 7 748 e a 2X 19 0 6 879 174 7 HANDLE SUPPORT 7 247 8 856 F 184 1 FLEXIBLE HANDLE 2249 Part 252055088 R 1 CASHFLOW SC83 Page 24 Technical Support 1 800 345 8172 www meiglobal com
13. TINGSOFTWARE Portable Programing Module PP N 12 13 Replacing the Eprom 14 15 HARNESSINGAND CONNECTORS Ph Int D t C Pim Oul u u uuu Sasa EE aE EOE EONS erae ria 16 ee it D oe Pn Eegeregie 16 COUPON Coupon Configuration Instructions 17 C WE 18 MAINTENANCE Cleaning the Acceptor Module 19 C ii iii o n sS 19 TROUBLESHOOTING RE e TE 20 Frequently Asked Questions 21 25 SC83 DIMENSION DRAWINGS 26 Technical Support 1 800 345 8172 CASHFLOW SC83 Page 2 www meiglobal com Part 252055088 R1 OVERVIEW Model Number SC 83 XX X Flash Unit blank P Prom Unit 00 OEM Configurable No Harness 02 OEM Proprietary 04 Opto Isolated EBD S 07 RS232 EBD S Secure Cashbox 83mm bill path FBDS is a MEI protocol EBDS stands for Extended bi directional serial Note Other interfaces will also be supported Serial Number WW Y LCC Sequential Production Number Configuration Code Manufacturing Location Year Manufactured Last digit of year Week Manufactured 0 52 When installing the SC83XX into a host machine turn off all power
14. ade you will need to line up the locating holes on the bottom of the chassis with the machine s locating pins Then line up the mounting screw holes and insert M4 screws through as many of the 10 mounting holes There are three on each side of the chassis and four located on the back Leave screws slightly loose until the bezel is mounted and aligned with the machine door closed Screws must not exceed a 6mm depth through the mounting plate otherwise they may interfere with the removable cashbox Technical Support 1 800 345 8172 CASHFLOW SC83 Page 7 www meiglobal com Part 252055088 R1 INSTALLATION Inserting And Removing the Acceptor Module e Insert the Acceptor Module so that the release lever locks into place e To remove the unit pull upwards on the release lever located on the front of the Acceptor Module and pull away from the chassis Acceptor Module Technical Support 1 800 345 8172 CASHFLOW SC83 Page 8 www meiglobal com Part 252055088 R1 INSTALLATION Installing A Bill Entry Guide e To install a bill entry guide just slide it onto the Acceptor Module until it locks into place No screws are required If the bill entry guide has lights you will have to first connect the har ness from the bill entry guide to the eight pin connector located on the left hand side of the face of the Acceptor Module e Make sure that the bill entry guide is aligned so the machine door closes properly Eight pin harness connector
15. cceptor and a host machine It is not used for interfacing to IGT machines Open collector EBDS uses opto isolated interface hardware RS 232 EBDS uses RS 232 level interface hardware IGT Netplex Serial Protocol is proprietary IGT interface used to communicate between the IGT host machine and the Bill Acceptor Technical Support 1 800 345 8172 CASHFLOW SC83 Page 21 www meiglobal com Part 252055088 R1 FREQUENTLY ASKED QUESTIONS 12 HowisaCASHFLOW SC83 unit manufacturing date determined Locate the unit s serial number on the product label The product label is located on the front of the Acceptor below the BEG The first three digits of the serial number are the date code of the bill acceptor The first two digits indicate the week of the year it was made The third digit indicates the year of manufacture For example 082 means the unit was manufactured the 8th week of 2002 13 How do I and how often should I clean the CASHFLOW SC83 unit The best way to clean the bill acceptor is with mild non abrasive diluted cleaning solution sprayed onto a soft cloth and not directly onto the bill acceptor Remove the Acceptor and open the bill acceptor mouth Wipe out the bill path Cleaning should be performed after two years depending upon use or if the unit s acceptance rate drops below normal 14 Can I use alcohol to clean a CASHFLOW SC83 unit Alcohol is not the preferred cleaning solution Refer to Question 13 15 Can I
16. ill entry guides fit in every machine Your choice regarding bill entry guides will depend on machine specifications Below are two bill entry guides that we currently manufacture For customers who prefer to tool their own bill entry guide please contact our technical department Platform Bill Entry Guide Universal Bill Entry Guide Power Specification Input Voltage 12 28 VDC Standby 10 Watts Acceptance Peak 30 Watts Stacking Peak 70 Watts Technical Support 1 800 345 8172 CASHFLOW SC83 Page 6 www meiglobal com Part 252055088 R1 INSTALLATION gt Note Always power down machine prior to Installation The cashbox does not lock to the chassis When you remove the unit from the container or when the unit is not installed in the machine you must never carry the bill acceptor by the handle of the cashbox The cashbox may release causing the rest of the unit to fall and damage the chassis Installing The Chassis e Most models have a configuration specific cable installed on the back of the chassis see Interface Manual 002850103 for more details Connect the cable from the chassis to the machine Always dress all wires to avoid interference with any equipment operation Mounting Holes Mounting Holes use M4 screws use M4 screws Locating Holes Back Side Bottom Note If you have a custom configuration you may need to contact our technical support group for assistance e Once the connections are m
17. irst connect a USB cable to the front of aCASHFLOW SC83 unit then connect the other end to the PPM Then press the yellow button and the PPM downloads new software into the CASHFLOW SCH unit The PPM uses the red and green LED s to report its status and also give error messages For more information on the PPM refer to the PPM User Guide Technical Support 1 800 345 8172 CASHFLOW SC83 Page 19 www meiglobal com Part 252055088 R1 FREQUENTLY ASKED QUESTIONS 6 Can a PPM be used to update software for PROM CASHFLOW SC83 units No A PPM can only be used to download software into Flash CASHFLOW SC83 units 7 How can I tell the difference between a Flash and PROM CASHFLOW SC83 unit On purchased units that have not be modified PROM CASHFLOW SC83 units should have a P after the model number Flash CASHFLOW SC83 units will not have a designator after the model number Examples SC8302 Flash CASHFLOW SC83 unit SC8302 P PROM CASHFLOW SC83 unit 8 What are the MMI Diagnostic Error Codes Green Yellow and Red LED MMI Indicator Status Activated by Slot Technician Needs Green Solid Normal Normal Power up None Green 1 flash Disabled by 1st Gaming machine due Clear the condition on interface to other condition like the gaming machine that empty coin hopper caused the banknote This is delayed by 10 acceptor to be disabled seconds see Note 1 Green 2 flashes No communication by No communication by In
18. ns occur the most severe condition will be displayed Red conditions Hard Fault One of the bill acceptor components needs to be replaced Q Yellow condtions Soft Fault The operator can correct the issue at the machine Q Green conditions No Fault No problem with the bill acceptor 8 galid Light F Fash LED INDICATORS STATUS Green Ei Maer Green Lei Deeg by machine ren G Beie mas ma mone in Green CODO raeed Yellow z Gash box not seated or not sent Seilen J Poy sacaqnanas Yellow L L jam n acceptor Yellow Q Pi 7 Jam n cach Bem Rea Ka Gash bo full Reri La Ancestor hamware fault Pel Gy karaos boari hawar sult fni GGG Lemos urut Take re actori Fa the machine condition ep fill he Coen tes Comect the rgtercgie Ronen Pesan the asi In Deen the acceptor De ge jeer kum Ihe re Remi ge KEIN an Oy Ip Go EE Replace with an empty CP Da Repe the arem wth d POET Hen pepa the interface Wai Pigan unt wf a marie UA Note By opening the machine door you will disable the primary interface The 10 second delay allows you to see a normal condition on the unit prior to the MMI display update Technical Support 1 800 345 8172 www meiglobal com CASHFLOW SC83 Page 18 Part 252055088 R1 FREQUENTLY ASKED QUESTIONS 1 What are the 3 parts that make up a CASHFLOW SC83 unit A CASHFLOW SC83 unit consists of an Acceptor Chassis and Cash Box For more information on
19. r area Forcing the bill path open without removing the Acceptor Module from the chassis will damage the connector board located at the rear of the Acceptor Module Remember to turn off the machine as per machine manufacturer when performing any cleaning e Release the Acceptor Module from its normal operating position e Open the Acceptor Module unit by pulling up on the yellow cap e Clear the bill path area of any foreign objects e Clean bill path and sensor areas as needed For stubborn dirt a small amount of mild non abrasive soap may be applied to a damp cloth Make sure no streaks or residual from the cleaning product remain on the bill path Note SC amp 3 does not require the use of a cleaning card Never use a petroleum based product to clean this device Petroleum based products will damage the bill path Mild non abrasive soap is preferred over alcohol Calibration The SC83 series bill acceptor was designed not to require calibration Thus the unit has no Switch settings or calibration mode that allows a user to perform a calibration Calibration may only be performed by one of our trained technicians Technical Support 1 800 345 8172 CASHFLOW SC83 Page 17 www meiglobal com Part 252055088 R1 Diagnostic Codes The chart below indicates the 15 color coded combinations of diagnostic LEDs on the acceptor module For each color there is a solid indicator and four flashing combinations If multiple failure conditio
20. use cleaning cards Not necessary Cleaning cards offer simple preventative maintenance for some bill acceptors Since the CASHFLOW SC83 unit is easily opened more effective cleaning can be accomplished with a soft lint free cloth and an appropriate cleaning solution Refer to Question 13 16 What is the operating voltage fora CASHFLOWTM SC83 unit The operating voltage range is 12 to 28 VDC 17 DoesaCASHFLOW SC83 unit have dip switches A CASHFLOW SC83 unit does not have any dip switches Bills can be enabled and disabled by using a configuration coupon Contact MEI for more information 18 What is the purpose of the red black and white wires that come out of the main cable The wires are connected to an internally mounted switch and are used in conjunction with Player Tracking Systems to identify that a cassette cash box is present or that it has been pulled Different combinations allow Normally Open or Normally Closed wiring Technical Support 1 800 345 8172 CASHFLOW SC83 Page 22 www meiglobal com Part 252055088 R1 FREQUENTLY ASKED QUESTIONS 19 How do I clear a bill jam Remove the acceptor by pulling upwards on the release lever located on the front of the Acceptor Module and pull away from the chassis O pen the Acceptor by sliding the yellow Acceptor Latch forward then clear the bill jam 20 IsitOK to swap Acceptors among my machines Like model number Acceptors may be easily swapped i e SC830
21. vestigate amp Correct 2 interface 2 interface only used Issues with 2 interface with 2 interfaces Green 3 flashes Not used Green 4 flashes Not used Yellow Solid Cash Box unseated Cash Box not present To be able to reseat the not present Cash Box Yellow C flash Poor Acceptance Need for cleaning Needs to clean acceptor Yellow 2 flashes Jam in Bill Path Self evident condition To clear jam and jam rate on system Yellow 3 flashes Jam in Cash Box Self evident condition Need to check Cash Box Yellow 4 flashes Not used Red Solid Cash Box Full Self evident condition Need to swap Cash Box Red 1 flash Hardware Fault Auto detected failure Need to swap the Acceptor Acceptor in Accceptor Red 2 flashes Hardware Fault Auto detected failure Need to swap Interface Communications in Interface Card Board Red 3 flashes Not Used Red 4 flashes Hardware Fault Auto detected failurein Need to swap Cash Box Cash Box memory Cash Box memory system Green Red Yellow Hardware Fault Unit not programmed Need to use PPM to or PROM Solid Green and Red Calibration Mode Self evident condition Insert SC83 Calibration Test Flashing Coupon Note 1 Opening the machine door will disable the primary interface The 10 second delay is to allow the technician to see anormal condition on the unit prior to the MMI display update to disabled Technical Support 1 800 345 8172 CASHFLOW SC83 Page 20 www meiglobal com Part 252055
Download Pdf Manuals
Related Search
Related Contents
IBM eServer xSeries 206 3.4 GHz 1MB 256 MB SATA o/b EM64 exclusief power cord a Ear Force Foxtrot pdf à télécharger Anleitung - CONRAD Produktinfo. 1 - Vivotek RBAND/OS – RBAND/OSB - JCM Technologies SA Manual de Instruções Copyright © All rights reserved.
Failed to retrieve file