Home
User`s Manual - Gtest.com.ua
Contents
1. BA HOLD MIN KFc 6 Operating Instructions 1 Open battery cover and install a 9 volt battery in the battery compartment 2 Install the battery compartment and lock the screw 3 Power the meter on 4 Press MODE key to select the desired function Notes When the low battery icon mele appears replace the meter s battery Hold the meter in hand or use the tripod to affix the meter in the desired location The best measuring distance is 1 1 5m away from the microphone to the sound source When the AC adapter is used insert the plug of the adapter 3 5 into the DC 9V connector on the side panel 7 Operating Procedures 7 1 Temp Humidity reading selection After power the meter on press key to select Temperature reading or Humidity reading 7 2 Backlight ON OFF After power the meter on press E key once the backlight will be on press this key again to turn it off The backlight will be automatically turned off after approx 30 seconds of inactivity 7 3 Data Hold Press Cj button once HOLD icon will appear on the LCD which indicates the data is freezed To release the held reading press the button again 7 4 Units selection 7 4 1 Measuring Air Velocity e 1 After entering Air Velocity mode press button to select desired units they appear in turns cyclically m s km h ft min knots Mph 7 4 2 Measuring Light 2 After entering Light mode press rs button t
2. User s Manual 5 In 1 Multifunctional Environment Meter MAXKLuxdBA HOLD MIN KFc Please read this user s manual thoroughly before using this unit and keep it properly for your future Contents DEES aleu sense eet ne ret E etre ES 1 QalMinOdUCU ONE aaa aaa nasag E sa aa aaa aaa ngana a a I Spec ification S HI Na NGNE a en EN 3 AMIN eter D CSCHIPELO Taree rere tree erent ere eee 5 5 LCD Display Description ccsscescsesseeeseeeseeeees 7 GUD crac 8 AO IWIES Ti KN NK 9 NC ak fearon a aa 13 QUIN CCE SSODIES a E 13 1 AAN Safety Read the following safety information carefully before attempting to operate or service the meter Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired Environment conditions Altitude less than 2000 meters RH lt 90 Non Condensation Operating Temperature 30 C 60 C Maintenance Repairs or servicing not covered in this manual should only be performed by qualified personnel Wipe the unit with a dry soft cloth Do not use abrasives or solvents on this instrument Safety Symbol C Coa with EMC 2 Introduction The 5 in 1 digital Multifunctional Environment Meter is designed to combine the functions of Sound Level Meter Light Meter Anemometer Humidity Meter and Temperature Meter It is an ideal M
3. o select Lux or Fe 7 5 Power ON OFF Turn the meter on by pressing button for 1 second and turn the meter off by pressing and holding button for at least 3 seconds 7 6 MODE button After power the meter on press da button to select desired function they appear in turns cyclically Sound Level Air Velocity Light 7 7 MAX MIN record In the measurement mode press the E key for one time to enter MAX MIN measurement MAX will appear on lower LCD the captured maximum value will be displayed on the LCD Press the key again MIN will appear on lower LCD and minimum value will be displayed on the LCD Press the key once again to exit MAX MIN measurement mode 7 8 Temperature units selection After enter measuring mode press Qe button to select C or F 7 9 Sound Level Calibration Procedure 7 9 1 Set frequency weighting as A weighting dBA 7 9 2 Insert the microphone housing carefully into the 1 2 inch insertion hole of the calibrator 94dB 1kHZ 7 9 3 Turn on the switch of calibrator and adjust the CALL potentiometer until 94 0dB is displayed Acoustic Calibrator NOTE All products are well calibrated before delivery Recommended recalibration cycle 1 year 8 Notes 1 Do not store or operate the meter in high temperature or humidity 2 Remove the bat
4. tery when the meter is to be stored for long periods of time to avoid battery leakage 3 Wind blowing across the microphone increases the noise measurement Use the supplied windscreen to cover the microphone when appliance 4 Keep microphone dry and avoid severe vibration 9 Accessories User s manual Temperature and Humidity probe Anemo probe Light detector Windscreen Regulatorrod Tripod Optional OOS O O oO 9V battery and Adaptor Optional
5. ultifunctional Environment Meter with different practical applications for professional and home use like monitoring and collecting data of environment temperature and humidity measuring noise in factories schools offices airports home etc 3 Specifications Sound Level Applied standard IEC61672 1 CLASS2 Accuracy 2 0dB Display Adigts Resolution 0 1dB Frequency response 31 5Hz 8kHz Measurement range Auto 35dB 130dB Frequency weighting dBA Microphone 1 2 inch Electric condenser microphone Light Measuring range 0 Lux 200K Lux 0Fe 20KFe Spectral response CIE photopic CIE human eye response curve Spectral accuracy CIE VAfunction fl 6 Cosine response PE 2 Accuracy 4 rdg 0 5 f s lt 10 000Lux 5 rdg 10dgts gt 10 000Lux Photo detector One silicon photo diode with filter Air velocity Air velocity range 0 5m s 30 0m s Air velocity accuracy 3 0 3d Measurement units m s km h ft min knots Mph Temperature Measurement range 40 70 C 40 158 F Accuracy 2 0 C 3 6 F Measurement units CR Resolution 0 1 Humidity Measurement range 10 95 RH Accuracy 5RH Resolution 0 1 Data update 1 time sec Maximum value MAX Minimum value MIN Data Hold HOLD Auto power off Automatically power off after approx 15 min
6. utes of inactivity Power supply one 9V battery with type of 006P NEDA1604 or IEC6F22 Battery life About 30 hours Operating condition 20 C 60 C 10 RH 90 RH Storage condition 40 C 60 C 10 RH 75 RH Dimensions 252 L 66 W 33 H mm Weight 568g 4 Meter Description Windscreen microphone cover A Microphone LCD display Temp Humidity selection key Backlight ON OFF key HOLD key Units selection key DIS 2 o es Power ON OFF key D rh MAX KLux dBA HOLD MIN KFc Function selection key MAX MIN C F selection key Potentiometer calibration for sound level Anemo probe and Photo detector terminal Temperature and Humidity sensor interface External DC 9V power supply terminal positive inside and negative outside Pore size OD 3 5mm ID 1 35mm Tripod nut 4 les o gt 47 Battery Compartment P x yy Battery Compartment screw 5 LCD Display Description G Temp Humidity reading display 2 Battery indication 3 Temperature unit icon 4 Humidity unit icon 5 Air velocity unit icon 6 Sound level Air velocity or Light reading display 7 Sound level unit icon D D Light unit icon 1 5 cr MAX MIN Lt Data Hold pgp pi ma Gi Power off Timer I X 6 UU _ MAX KLux d
Download Pdf Manuals
Related Search
Related Contents
pliegos técnicos IOM 30HKS 20-60TR_194.01.011-F-04 A-PDF PageMaster Demo. Purchase from www.A-PDF Philips 046677410292 energy-saving lamp 等 ( とう ) が 行 ( おこな ) うべき 事項 PS 2013/14 User Manual (Opens in a new window) Copyright © All rights reserved.
Failed to retrieve file