Home

IEXT IEHR DC/DC converter - user manual

image

Contents

1. linearly derate to 50 output at l l Temperature 50 C Use with laptops Some laptops require a SENSE terminal the diode is replaced with a resistor and the Specifications are subject to change without prior notice www innovative co nz 2 Dunna wae Converter Ll EX lf Wars STANDARD MODEL TABLE IEXT 70 Watt 1 Model codes without DC Input DC Output 41 i the P suffix do not have MODELS Voltage x4 Amps Voltage diode and alarm relay fit Voltage Range Range ted 2 IEXT LV 05P 2 No overvoltage protec IEXT LV 12P tion IEXT LV 18P IEXT LV 24P IEXT LV 48P 4 Refer to terminal con nections below Output IEXT MV 08P 7 6 9 5 voltage is set at D output except for 12V models IEXT MV 12P 11 14 where the output is set lEXT MV 18P l 16 6 20 3 to 13 8V IEXT MV 24P 22 28 IEXT MV 48P 43 55 2 IEXT HV 12P IEXT HV 24P IEXT HV 48P 3 No input rectifier bridge STANDARD MODEL TABLE IEHR 150 Watt DC Input DC Output x1 MODELS Voltage Voltage x4 Amps Voltage Range Range IEHR LV 12P IEHR LV 24P IEHR LV 36P IEHR LV 48P IEHR 24 12P IEHR 24 24P IEHR 24 36P IEHR 24 48P IEHR 48 12P IEHR 48 24P IEHR 48 36P IEHR 48 48 IEHR HV 12P IEHR HV 24P Dimensions IEXT 180L x 82W x 37H Dimensions IEHR IEHR HV 36P l 207L x 130W x 60H IEHR HV 48P TERMINAL LAYOUTS IEXT Green LED indicates output present IEHR VA et O No Kc Ral al INPUT ALARM CONTACTS
2. 6 mm Transient Protection Input varistor IEHR To flat surface with brackets supplied M4 holes Isolation 1KV DC input output chassis Side mounting centres 140 x 78 mm End mounting centres 216 x 78 mm Efficiency LV 72 80 MV 24 48 80 87 HV 85 87 Overvoltage Protection Operates at 25 above nominal output volt OPTIONS IEXT only age converter shuts down reset by power Rack mount Converter fitted into 19 x 2U subrack off Add RM2U plus REARHR6 1 Soft Start 1 second typical DIN Rail Mount Using DIN rail clips code DINKIT Output Power IEXT 70W continuous Fork Hoist Use Please contact our sales office add option IEHR 150W continuous FORKHOIST Output Voltages Refer to model table other voltages availa Low Temperature Operation to 20 C add sufix LT ble please ask our sales staff l l Conformal Coating For harsh environments add option Voltage Adj Range Approx 10 refer to model table CONFORMAL COATING Line Regulation lt 0 5 over input range Battery Charging The IEXT has a constant output current limit Please specify output and is suitable for battery charging Load Regulation lt 0 7 open circuit to full load voltage on ordering The IEHR does not have a constant current limit but may be used for battery charging for Ripple Typically 1 Peak Peak some applications EMC To CISPR22 1985 Undervoltage lockout Available on IEXT LV models Lockout at 10 2V auto reset at 12 4V add suffix UV Operating 0 to 40 C
3. OUTPUT VOLT ADJ POT DIODE OUTPUT Specifications are subject to change without prior notice www innovative co nz 3 L ait he Installation amp Saey A AN N N Safety The user is responsible for ensuring that input and output wiring segregation complies with local standards and that in the use of the equipment access is confined to operators and service personnel A low resistance earth connection is essential to ensure safety and additionally satisfactory EMI suppression see below HAZARDOUS VOLTAGES EXIST WITHIN A POWER SUPPLY ENCLOSURE AND ANY REPAIRS MUST BE CARRIED OUT BY A QUALIFIED SERVICEPERSON Electrical Strength Tests Components within the power supply responsible for providing the safety barrier between input and output are construct ed to provide electrical isolation as required by the relevant standard However EMI filtering components could be dam aged as result of excessively long high voltage tests between input output and ground Please contact our technicians for advice regarding electric strength tests Earth Leakage Where fitted EMI suppression circuits cause earth leakage currents which may be to a maximum of 3 5mA Ventilation High operating temperature is a major cause of power supply failures for example a 10 C rise in the operating temper ature of a component will halve its expected life Therefore always ensure that there is adequate ventilation for
4. ative Energies Ltd warrants its power supplies for 24 months two years from date of shipment against material and workmanship defects Innovative Energies liability under this warranty is limited to the replacement or repair of the defective product as long as the product has not been damaged through misapplication negligence or unauthorized modification or repair Specifications are subject to change without prior notice www innovative co nz 4
5. ovative energies n c Ee aa aa O AS gt ISO9001 Certified User Manual IEXT IEHR 70 150 Watt DC DC Converter Z367 Specifications are subject to change without prior notice www innovative co nz 09 06 15 WEA amp Wein Ans DC gt DC converters ovative energies Isolated input output chassis Designed for industrial use Output over voltage protection IEXT Constant current limit for charging IEXT Input transient surge suppression Short circuit protection Reverse polarity protection External trim pot for output voltage adjustment Output decoupling diode and dc fail alarm standard 24 Month Warranty SPECIFICATIONS All specifications are typical at nominal input full load and at 20 C unless otherwise stated ELECTRICAL PHYSICAL DC Input nominal 12 24 36 48V Connections In Out IEXT Plug in screw terminal block IEHR Barrier type screw terminal Protection input All models Input fuse Enclosure Base anodised aluminium e output IEXT Overload constant current limit Cover black powder coated mild steel Severe overload shuts down when output lt 5V power off to reset Indicators Green LED for Power On IEHR Hiccup mode current limit Weight IEXT 450g IEHR 1 25Kg Reverse Polarity IEXT LV amp IEHR input fuse Mountin l IEXT MV amp IEXT HV not polarity sensitive owe EATS Mo holas 164 x 40 mm andion M3 threaded inserts 164 x 6
6. the equipment Batteries in particular suffer shortened lifetimes if subjected to high ambient temperatures Water Dust Every effort must be made in the installation to minimise the risk of ingress of water or dust Water will almost always cause instant failure The effects of dust are slower in causing failure of electronic equipment but all electrical equip ment should be cleaned free of any dust accumulation at regular intervals Electromagnetic Interference EMI Switching power supplies and converters inherently generate electrical noise All wiring should be as short as practica ble and segregated from all equipment wiring which is sensitive to EMI Residual noise can be reduced by looping DC wiring through ferrite cores sleeves These are most effective as close to the power supply as possible and as many turns of the wire taken through the core and in the same direction as the core will accommodate External fuse protection Fuses or circuit breakers must be used in all battery circuits to protect against short circuits External fuses should be used for power supplies chargers even though they are usually internally protected Connection polarity It is critical to check the polarity carefully when connecting DC devices Some Innovative Energies models have non destructive reverse polarity protection but usually a reverse polarity connection will result in a blown fuse or serious damage to the device WARRANTY Innov