Home
User Manual - CommDTM ET 200M
Contents
1. CommDTM ET 200M User Manual English Dear Customer This User Manual describes the functionalities of the CommDTM for the Remote I O SIMATIC ET 200M in a FDT frame application If you have any further questions please contact our Technical Support Trebing amp Himstedt Proze automation GmbH amp Co KG Technical Support Wilhelm Hennemann Str 13 19061 Schwerin Germany Phone 49 385 39572 500 Fax 49 385 39572 22 E mail support t h de Internet http www t h de The information contained in this User Manual is the property of Trebing amp Himstedt Proze automation GmbH amp Co KG The User Manual and extracts thereof may only be duplicated or forwarded to third parties following explicit written approval by Trebng amp Himstedt Proze automation GmbH amp Co KG We reserve the right to make changes and improvements to this User Manual as well as the hardware and software features at any time and without prior notification All product names used herein are trademarks or otherwise protected by law even if not specifically indicated 2005 2010 Trebing amp Himstedt Proze automation GmbH amp Co KG Doc Version 4 0 January 2010 Content CommDTM ET 200M asseeeseseenreineeee ee 4 FDT Frame Applications aussen 6 Context Men ssssssise aleren eere EE MEHEHEEEREEREEEEEEUEEENEREFEUEEFERFEEGERELNERRPRFR 7 Change Device Addresses rrrnnnrnvvrnnnnnrrvvvrnnnnnnssvvvsvnnn
2. ET 200M 14 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Types of Licenses In the following table you licenses Licensing find an overview of the types of Type of license Explanation Demo version days remaining without functional limitations DTM is not licensed Trebing Himstedt DTM Library Full License License valid for all DTMs from the Trebing Himstedt DTM Library Trebing Himstedt DTM Library Single License License valid for one DTM from the Trebing Himstedt DTM Library No license demo version expired DTM projecting possible no online connection can be established 15 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application Example Application The CommDTM ET 200M allows access to HART field devices HART field devices do not have a PROFIBUS address Every device is operated through one channel of the HART modules of the ET 200M The PROFIBUS communicates acyclically via an MCL2 configuration master For communication with field devices the respective field deviceDTM needs to be integrated into the project ofthe FDT frame application Via this integration the field deviceDTM is assigned to the respective HART module channel of the ET 200M PACTware FL FieldCare Device Setup Advanced FieldCare DEN FieldMate M Certified Network Tag Host PC
3. in the project window with the right mouse key and selectAdditional Functions gt Change device addresses Select the channel where the field device for which you want to change the address is connected and click the Refresh button Afterwards the field device is listed in the Change device addresses window Respective device name DTM vendor and DTM version can only be displayed if this functionality is supported by the frame application Mark the field device Select a new address from the list box Current device address in the bottom part of the window and click Accept Automatically an online connection to the field device is established the address is modified and the field device disconnected In the status bar of the window information is displayed on whether this function has been completed successfully or whether the device does not support this functionality Attention A After device address modification you need to set the DTM address of the respective deviceDTM to the same address Note Not all devices support device address setting through the CommDTM ET 200M Device addresses for some field devices can only be set directly at the field device For respective information please refer to the manual of the respective field device vendor e CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu Change DTM Addresses With this function you can display and chang
4. NT M PA V1 0 Channel 0 114 Addresses Z PROSONIC FLOW 90 P Channel 0 57 X Change DTM Addresses About the CommDTM ET 200M Help t Licensing L CommDTM ET 200M E Types of Licenses Example Application BE Design Projects Requirements FDT frame application Add CommDTM PROFIBUS DP V1 Add CommDTM ET 200M Add PROFIBUS English deviceDTM E Online Offline Operation EHE General Conditions E Right to make additions or Co B Lesezeichen Doc Version 4 0 User Manual i Network CommDTM ET 200M Trebing Himstedt Proze automation GmbH Co KG 3 0 0 3 Administrator Administrator 2 Fig 7 User Manual 13 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Licensing Licensing The CommDTM ET 200M is protected by software key You need to license the software for unlimited use Without licensing you can use the CommDTM ET 200M as a demo version with unlimited functionality for 30 days from date of installation After expiry of the 30 day demo version online connections can no longer be established At the time of expiration existing online connections will be terminated r Note 1 The license is generated for the current system License transfer to other systems is not possible You can find the current license status in the window About CommDTM ET 200M context menu gt Additional Functions gt About CommDTM
5. PROSONIC FLOW 90 P dp Channel 0 57 CommDTM ET 200M 3 0 0 3 Trebing Himstedt DTM Library Full License Instructions Open folder Trebing amp Himstedt Proze automation GmbH amp Co KG support t h de www th de s Network t CommDTM ET 200M About CommDTM ET 200M Administrator Administrator Fig 6 About CommDTM ET 200M Procedure for opening the window About CommDTM ET 200M Click CommDTM ET 200M in the project window with the right mouse key and select Additional Functions gt About CommDTM ET 200M The information about the CommDTMET 200M opens 12 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu Help This function starts the User Manual in PDF format Adobe Acrobat Reader is required Installation of the Trebing Himstedt DTM Library saves the user manual locally on your system FieldCare Device Setup Advanced r User Manual CommDTM ET 200M pdf Adobe Acrobat 3D Network Tag Conn Channel Address Devic host PC ER CommDTM PROFIBUS DP V1 1 E A CommDTM ET 200M gt Channel 0 110 go ME Volume Flow Slot 8C 0 m eu k MICROPIL 4 Slot 8C 1 g E A CommDTM ET 2005P Channel 0 111 CommDTM ET 200M SE CERABAR 4 Slot 4C 0 DELTABAR Slot 4C 0 5 Ja E TEMP Slot 4C 0 3 8 CommDTM DP PA Link Channel 0 120 Context Menu BE ESK2PA Channel 0 E Change Device e LIQUIPHA
6. Qg CommDTM PROFIBUS DP V1 E Se M8 Volume Flow 2 MICROPIL Qe CommDTM ET 200SP A CommDTM DP PA Link Ethernet PROFIBUS DP Fig 8 Communication principle to field devices 16 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application Design Projects Requirements The following software has to be installed FDT frame application Trebing Himstedt DTM Library HART field deviceDTM FDT frame application Startthe FDT frame application Open and update the device catalog Create a new project Add CommDTM PROFIBUS DP V1 Click Host PC in the project window with the right mouse key and select the function Add device Select CommDTM PROFIBUS DP VI1 from the device catalog and click OK Configure the CommDTM PROFIBUS DP V1 To do so open the CommDTM PROFIBUS DP V1 context menu and select Configuration For further information please turn to the CommDTM PROFIBUS DP V1 user manual 17 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application FL FieldCare Device Setup Advanced Eile Edit View Device Operation DTMCatalog Tools Window Extras Help jose oa g Network Tag Conn Channel Address Device typ El Host PC i TEE pf 4 on 8 pap UT Fig 9 Added CommDTM PROFIBUS DP V1 Add CommDTM ET 200M Click Co
7. ame Application Help Depending on the selected device you can now read out the configuration or write the configuration set in the FDT frame application to the device To do so use the respective function in the context menu Terminate the online connection by clicking on the respective entry in the project window with the right mouse key and selecting Go Offline Note You need to establish connection for each field device You can terminate the connection for each single field device The connection is established and terminated via the context menu of the respective field deviceDTM me If you terminate connection to the CommDTM ET 200M or to the CommDTM PROFIBUS DP V1 all online connections to the field devices are terminated automatically 23 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG General Conditions General Conditions Right to make additions or alterations Trebing amp Himstedt Proze automation GmbH amp Co KG reserves the right to continue development of this user manual and the properties of the hardware and software at any time also without releasing information about this or about alterations prior to doing so Exclusion from liability Trebing amp Himstedt ProzeRautomation GmbH amp Co KG assumes no warranty for proper function of the hardware and software in all conceivable situations Currently available technical means do not enable the development
8. e DTM addresses of subordinate field deviceDTM This function is only available in offline mode The DTM address shown and set is used to establish connection to the respective field device Please make sure to use an identical address both for the field device and for its respective DTM PL FieldCare Device Setup Advanced CommDTM ET 200M Change DTM addresses DER id Fie Edit View Device Operation DTMCatalog Tools Window Extras He bel Sed Network Tag Conn Channel Address Devic EM B Hos PC EQ CommDTM PROFIBUS DP V1 Be TM ET 200M 4p PROFIBUS Remote I O 1 Channel 0 110 CommDTM ET 200M A 38 M8 Volume Flow Sit 8C 0 DTM address Tag Daves 4 0 olurne Flow 0 MICROPIL J MICROPIL E A CommDTM ET 2005P R M8 Volume Flow E CERABAR Micropilot M FMR 25x V5 xx 32 LIQUIPHANTM PA V10 4 PROSONIC FLOW 90 P 4 z z etres Close Network CommDTM ET 200M Change DTM Adresses 1 Administrator Administrator Fig 5 Change DTM addresses Procedure for changing DTM address Click CommDTM ET 200M in the project window with the right mouse key and select Additional Functions gt Change DTM addresses The scan procedure is performed by clicking the Refresh button 10 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu Afterwards the DTM addresses are listed in the Change DTM addresses
9. envensnnnn 8 Change DTM Addresses rrrannnnnvnnnnnnnnnrrvvvvnnnnnnnenvernnnnenennvnnnn 10 About the CommDTM ET 200M arunrnnnnnnnnvrvvrnrrnnerrennnnnnnnrneeen 12 EEE ERE 13 HEEN mere cect ARRRIEEELETEEFRERFERTTEBIRRFREREEINRRRREREGTERTELTEFTEIFEREERERERERE 14 Example Application aussen e 16 Design POPES ernannt 17 Online Offline Operation rrvrrrnrrnnnvvvnnnnnnvrvnnvnnnnnnnarnvvnnnnnnnnnnernnnessevnvnnnn 23 General Conditions 0 cccccccceccccecccceccececeececeeaecueaecueeeceeaeaesueaeaeeaeaeeneass 24 CommDTM ET 200M CommDTM ET 200M The SIMATIC ET 200M Remote I O frequently used in process control plants is an essential structural element for the connection of HART devices to PROFIBUS The respective CommDTM ET 200M developed by Trebing amp Himstedt Proze automation GmbH amp Co KG can be implemented into all FDT frame applications according to FDT Specification 1 2 Addendum There the DTM functions as a device driver enable DP V1 communication with HART devices at ET 200M peripheral device and its deviceDTM The CommDTM ET 200M considerably facilitates configuration parameterization and calibration as well as commissioning diagnosis and maintenance of field devices You can use the CommDTM ET 200M within one FDT frame application severalfold and concurrently depending on the available ET 200M peripheral devices in the PROFIBUS network To do so load the CommDTM ET 200M severalfold into the project w
10. ication are described in the FieldCare Help Fl FieldCare T NUN Endress Hauser EI New i P Create Project HART MultiDrop HART Point to Point Service Readwin 2 gt ar Profibus PROFIdtm Service Flow FXA193 Service Level 7231 Pressure FXA13 Fig 2 FieldCare CommDTM ET 200M Trebing amp Himstedt Proze automation GmbH amp Co KG Context Menu Context Menu Click an entry in the project tree in the project window of the FDT frame application with the right mouse key The context menu opens Its entries are default entries ofthe FDT frame application When you selectAdditional Functions the respective DTM entries are displayed Functionalities displayed in gray are not supported or already opened To select these functions an online connection might be necessary Integration ofthe CommDTMET 200M into a project is described in the chapter Example Application PL FieldCare Device Setup Advanced E BK Eile Edit View Device Operation DTM Catalog Tools Window Extras Help Dea se Network Tag Host PC hs CommDTM PROFIBUS DP V1 A CommDTM ET 200M ge M8 Volume Flow 2 MICROPIL EQ CommDTM ET 2005P e CERABAR 2 DELTABAR i ITEMP j A EQ CommDTM DP PA Link ner 2 ESK3 PA SE LIQUIPHANTM PA V1 0 Device type DTM info f PROSONIC FLOW 90 P Za Connect ania ie SPT 4 Channel functio
11. indow For the PROFIBUS DP V1 communication a respective physical access to the PROFIBUS and a respective CommDTM PROFIBUS DP V1 need to be available see figure 1 on page 5 You can use the Trebing amp Himstedt Proze automation GmbH amp Co KG Comm DTM PROFIBUS DP V1 with xEPI 2 or the CP5512 CP5611 hardware The CommDTM ET 200M is protected by software key You need to license the software see Licensing on page 14 Without licensing you can use the CommDTM ET 200M as a demo version with full functionality for 30 days from date of installation CommDTM ET 200M functionalities can be accessed through the context menu of the used FDT frame application CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG CommDTM ET 200M PACTware Rz FC FieldCare Device Setup Advanced FieldCare Ea Datei Bearbeiten Ansicht Ger tebedienung DTM FieldMate VCertified Ethernet xEPI 2 2 MICROPIL E A CommDTM ET 200SP E A CommDTM DP PA Link PROFIBUS DP Fig 1 Example of a PROFIBUS network with several ET 200M CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG CommDTM ET 200M FDT Frame Applications The different FDT frame applications vary in functionality and appellation of the various functions This user manual refers to the FieldCare frame application with regard to appellations Complete functions for the frame appl
12. ls A Slot 7 Channel 7 Slot 7 Channel 8 Slot 8 Channel 1 Slot 8 Channel 2 Slot 8 Channel 3 Slot 8 Channel 4 Slot 8 Channel 5 Slot 8 Channel 6 Slot 8 Channel 7 Slot 9 Channel 1 Slot 9 Channel 2 Slot 9 Channel 3 Slot 9 Channel 4 Slot 9 Channel 5 Slot 9 Channel 6 Fig 12 Select channel Establish an online connection see Online Offline Operation on page 23 21 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application FC FieldCare Device Setup Advanced Bile Edit View Device Operation DTMCatalog Tools Window Extras Help jo ca Sag Network Tag Conn Channel Address Device typ El Host PC CommDTM PROFIBUS DP V1 dp 3 CommD Ed CommDTM ET 200M Ap Chann 110 lt j CommD se S8 0 kl Fig 13 Added field deviceDTM P Note 1 You cannot modify the selected slot and channel number for a HART field deviceDTM If you do have to change the slot or channel number remove the DTM from the project via context menu and then reinsert the DTM again 22 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Online Offline Operation Online Offline Operation Establish an online connection to the PROFIBUS To do so click on an entry in the project window with the right mouse key and select Go Online The existing online connection is shown in the FDT frame application see FDT Fr
13. mmDTM PROFIBUS DP VI1 in the project window with the right mouse key and select the function Add device Select CommDTM ET 200M from the device catalog and click OK The window for setting DTM addresses opens 18 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application Fig 10 Set DTM addresses Set the DTM address and click OK 19 mm CommDTM ET 200M Trebing amp Himstedt Proze automation GmbH amp Co KG Example Application FC FieldCare Device Setup Advanced Elle Edit View Device Operation DTM Catalog Tools Window Extras Help Dbsases Network Tag Conn Channel Address Device typ te Host PC E CommDTM PROFIBUS DP V1 4p 3 Chann 110 amp se v F X Fig 11 Added CommDTM ET 200M Add PROFIBUS deviceDTM Up to 96 HART field devices can be connected to one ET 200M Likewise up to 96 HART field deviceDTMs can be intergated into the project Click Comm DTM ET 200M gt Add Device with the right mouse key Select the deviceDTM from the device catalog and click OK Select the slot with the respective channel for the HART field device numeration of slots channels see Siemens documentation for ET 200M Click OK 20 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application FC Assign Device to Channel Channels Count Assigned Device
14. ns Change device es About CommDTM ET 200M Help Fig 3 Context menu for the CommDTM ET 200M CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu Change Device Addresses With this function you can display and modify PROFIBUS addresses of the connected field devices This functionality is only available in online mode Field device addresses can only be changed if the respective field device supports this function PC FieldCare Device Setup Advanced CommDTM ET 200M Change device addresses EEK dd Eile Edit Viem Device Operation DTM Catalog Tools Window Extras Help De SeeD ET 200M lost PC PROFIBUS Remote I O E 3 CommDTM PROFIBUS DP V1 4 ow TM ET 200M 4 CommDTM ET 200M ITEMP BP CommDTM DP PA Link ESK2PA 4 3 UQUIPHANT M PA V1 0 4 32 PROSONIC FLOW 90 P 4 Channel Slot 8 Channel x Network Scanning finished CommDTM ET 200M Change device addresses Administrator Administrator Fig 4 Change device addresses Procedure for Device Address Modification Click CommDTM ET 200M in the project window with the right mouse key and select Establish Connection The existing online connection is displayed in the FDT frame application see Help for FDT Frame Application CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu Click CommDTM ET 200M
15. of software which is completely free of errors in all conceivable applications Trebing amp Himstedt ProzeRautomation GmbH amp Co KG does not accept any liability for damages both direct and indirect arising from the use ofthe hardware and software and the information contained in this user manual Duty to monitor products As part of our duty to monitor products we strive to warn about dangers we have identified which can result from the interaction of hardware and software and product use with third party products Monitoring is only possible if we receive sufficient information from our customers on the planned application s and the existing hardware and software components As a result of the complex interactions it is no longer possible for us to accurately identify all dangers and to check the effect on the overall system and in particular on our hardware and software if the conditions of application have changed and or hardware or software has been exchanged This user manual does not describe all technical characteristics of the hardware and software and their variants For more information please contact Trebing amp Himstedt Proze automation GmbH amp Co KG Warranty Our products are subject to warranty in accordance with our general business and delivery terms 24 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG
16. window Respective device names DTM vendors and DTM versions can only be displayed if this functionality is supported by the frame application Mark the respective DTM Select a new address for the field deviceDTM in the Current DTM address list box and then click Accept In the status bar of the window information is displayed on whether this function has been completed successfully or whether the DTM does not support this functionality pr Note 1 This function is not supported by all DTM In this case you can only modify DTM addresses directly through the field deviceDTM in the project 11 CommDTM ET 200M Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu About the CommDTM ET 200M This functionality displays information about the installed CommDTM ET 200M PC FieldCare Device Setup Advanced CommDTM ET 200M About CommDTM ET 200M DER l ie Edit vew Device Operation DTM Catalog Tools Window Extras Help n A E E x Network Tag Conn Channel Address Devic BE ar Host pc il ll Ifi PROFIBUS Remote vo EQ CommDTM PROFIBUS DP V1 1 gt li CommDTM ET 200M Channel 0 110 col ee ho a MB Volume Fow ip Shot BC 0 3E MICROPIL dp Slot 8C 1 EA CommDTM ET 200SP ip Channel 0 111 32 CERABAR 4 Skt 4C 0 ge DELTABAR Ip Sot 4C 0 ITEMP Ip S4C 0 QP CommDTM DP PA Link Jy Channel 0 120 f l ESK2PA ip Channel 0 f LIQUIPHANT M PA V1 0 4p Channel 114 F