MG6-F2

image

Contents

1. 28 USING SOFTWARE Menu commands Data Operation A Current Data Connect MG6 F2 and a PC turn on MG6 F2 run KSJ Data Operator set the upload date then click Upload button to upload data Notes The data is uploaded one by one group with sounds and flash indicating Uploading troubles can usually be settled according to the hints of a pop up window Historical Data Turn to the interface of Historical Data set a time interval for data inquiring then click the Query button to get a result 29 USING SOFTWARE Meter Setup This group of commands is used to set the measuring conditions of MG6 F2 ina communication state AAngle Mode There are six options to be select including single angle double angle and treble angle AGroup Presetting To preset a number of measurements in a group you can choose from 1 to 99 A Verified Values This is for modifying the verified values of the Calibrating Standard in the Holder Note It is very important to keep the verified values correct for a calibrating standard Therefor don t modify those values at will 30 USING SOFTWARE A Shutoff Time This command is for setting a no operation time interval for which the meter will be shut down automatically There are three options to be selected AClear Memory This is for cllearing all the data stored in the memory of MG6 F2 permanently And so It is better to reconsider bef
2. wasted batteries properly A The meter should not be taken down at will in order to avoid permanent damage 16 MENU OPERATION E Menu interface On the measurement Interface push the Menu Wheel to enter the menu interface as below m Option selecting Turn up or down the Menu Wheel to select the options Push down the Menu Wheel for entering your option selected The following describes what the symbols mean Return to the prior menu Selecttoreturn Enterthe next submenu Selectto enter Hint Anytime press the Measuring Button to terminate menu operation and return to the measurement interface MENU OPERATION n pement Option Select this option and push down the Menu Wheel to return to measurement interface B fate menu and its submenu ire Ha MENU OPERATION inal submenu In data menu select inquiry option and push down the Menu Wheel to enter the inquiry submenu Turn up and down to set the group number that you want to inquire and then push down the Menu Wheel to enter the inquiry interface Here you can browse all the measurements in this group by turning the Menu Wheel xx Notes 1 EES represents the first measurement i in a current group that has been preset to involve five measurements represents the averages of this group 2 Turn up and down the Menu Wheel to browse data Push down th
3. KSJ MG6 F2 GLOSSMETER USER s MANUAL Please read this manual seriously before using Made in China Add Middle of Binnan Street Dongbin Industrial Zone Donghai Bincheng Quanzhou Fujian 362000 China Tel 86 595 22391040 Fax 86 595 22391048 Website www ksj cn www glossmeter cn E mail sales ksj cn sales hidea cn CONTENTS Brief Introduction n Specifications EUER Main Functions Construction n Measurement n Warning And Notice ee ete RENAA Menu Operation pP PETRI Using Software n Trouble shooting Warranty RR E DE VAARA VARAN Packing List n aw BRIEF INTRODUCTION Thanks for your choice to purchase MG6 F2 MG6 F2 is designed and manufactured according to 1502813 and GB9754 It is also compatible with the standards of ASTM D523 ASTM D2457 GB T13891 GB7706 and GB8807 The technical parameters conform with JJG 696 2002 The gloss values can be traced to those of the National Primary Standards in SIMT in the P R China Main Applications e All kinds of coating and finishing surfaces such as paints varnishes printing ink etc Decorative materials such as marble granite polishing brick ceramic tile and so on The other kinds of materials and objects such as plastic woodenware paper etc SPECIFICATIONS Specifications Unit MG6 F2 Glossmeter Measuring Range GU Gs 60 0 0 119 9 Gs 60 120 1000 R
4. e Menu Wheel to return to the previous interface and press the Measuring Button to exit and back to the measurement interface 19 MENU OPERATION 15 Enter the submenu and turn the Menu Wheel to select to clear all data in memory Or else select Hii to exit amp Hil submenu En Menu and its submenu 20 MENU OPERATION submenu Enter the submenu turn the Menu Wheel to select a value and push down the Menu Wheel to confirm then turn the Menu Wheel to modify the value push down the Menu Wheel to confirm again It is the same operation for other values option Calibration menu turn the Menu Wheel to select down the Menu Wheel to confirm The calibrating will be carry out automatically and meanwhile the result will be shown in the Display Window Finally it will return to the measurement interface option and push yx Notes 1 Before calibrating be sure that the Calibrating Standard is clean 2 You can also calibrate the meter with Checking Standard that is available for purchase 21 gp MENU OPERATION menu and its submenu 22 MENU OPERATION submenu Only an angle mode for this model Shutaobf Tire submenu This menu is for setting a no operation time interval for which the meter will be shut down automatically In the menu select an option and push down the Men
5. ecessary to install a driver for a USB Adapter Please find the driverin the CD which comes with MG6 F2 26 USING SOFTWARE Software interface Interface of Current Data default Title Bar intuens KSJ gt Data Operator For KSJ Glossmeters Menu Bar und ib The uris ae orejas T average mdeMab tpbsdTme m 205095 onspmseden a7 msa msa anseo eaaa am spese cann 20805 9 18 2008 8 48 0 asoa 9 8 2008 8 48 0 asoa 9 18 2008 8 48 0 200085 9 5 2008 848 0 20605 9 8 2008 848 0 ases 9 18 2008 848 0 msgs an6 Baan megas an6a Baan 205065 9 16 2008 648 0 Upload Area Data Area 88888888888888 Function Area m Ready 4 USING SOFTWARE Interface of Historical Data Title Bar alol x Menu Bar Query Area Data Area Function Area of Phototesbeal nckurments KSJ 2 pus Operator For KSJ Glossmeters stor pcne 5 18 2008 91382563 Voies deco Angle Modo upload Tire 206055 9 1600 BABO 2055 ospa Baan 2055 aosa 9 15 2003 ees a050 9 15 2003 Bn 206155 9 18 2003 848 0 206155 9 18 2003 848 0 206055 9 18 2003 sen 206055 206055 206055 2068085 2068085 SED
6. esolution GU 0 1 1 Repeatability GU 0 2 0 2 Reproducibility GU 0 5 0 5 Deviation GU 11 5 1 596 Zero point Deviation GU 0 2 Operating Temperature 106 40C SPECIFICATIONS Specifications Unit MG6 F2 Glossmeter Storage Temperature 10 60 Relative Humidity Up to 85 no moisture condensation for operation Measuring Spot 9x16 Power Supply One AA sized battery 1 2V 1 5V Rechargeable or alkaline Consumption It s different to battery types An alkaline battery may support 20000 measurements or more Volume mm 155x48x75 without a holder Weight 9 400 with a battery and a holder MAIN FUNCTIONS MG6 F2 has the main functions as below eOne key to get a measurement The result will be automatically stored into memory eSelf diagnosis and self calibration This function help to find some faults and so you can deal with them in time eFriendly display interface In measurement mode current values averages and other information are synchronously shown on the Display Window The clear characters and simple menus make operation more easily ePresettable measurement number in a group According a requirement you can choose a proper number between 1 to 99 for a group A correct choice will make measurement and data processing easier eLarge memory for measurement data More than30000 measurements or 999 groups can be allowed to stored in MG6 F2 einquiry for data in mem
7. in unit lay in the Holder properly the meter can pass the procedure of self diagnose and self calibration 33 TROUBLE SHOOTING E Recalibate the meter A big temperature difference between environment and the meter would badly affect measuring and the warning message will be shown In this case please wait for a period of time till the temperature get to a balance and then calibrate the meter Moisture condensation When the meter is taken from a cold location to a hot environment moisture conden sation occurs easily If so don t use the meter any more and wait for the moisture to evaporate See above item also Corrosion caused by a bad battery A bad or over discharged battery will produce corrosive liquid to damage the electric poles and elements When it happens please remove the battery in time and clean the poles with a cotton bud dipped in absolute ethanol If the meter don t work well please contact us for repair 34 TROUBLE SHOOTING Problems with communication AFailing to communicate through a Series Port on a PC It is all right to use a Series Port to carry out a communication Problems usually occur because MG6 F2 don t connect with a PC properly e MG6 F2 is not in a turn on state No data is in meter s memory AFailing to communicate through a USB Port on a PC Please be sure that e driver of the USB adapter has been installed properly All connecting cables are con
8. ird of five measurements in the eighth group e Angle mode is shown in the first column the values of A current measurement in the second and the averages in the third 12 MEASUREMENT Deleting measurements To delete a current measurement please push down operation button for more than 2 seconds Note Only the measurements in a current group can be deleted one by one Turn off the meter The meter will shut off automatically according to the preset time See page 25 Note After turning off the meter will be in a sleeping state which consume little power Even so itis strongly recommended to remove the battery when no use for a long time interval 13 MEASUREMENT Notice e The holder removed from the main device should be kept in a safe and clean place to prevent from damage or pollution While measuring please keep environment light f rom directly irradiating into the Measurement Aperture If necessary especially under strong light shade it with a piece of light tight cloth A big temperature difference between environment and the meter would badly affect measuring In this case please wait for a period of time till the temperature get to a balance and then calibrate the meter again f measurement operation last a long time for example an hour or more it s necessary to recalibrate the meter Pay attention to keep Calibrating Standard and Measurement Aperture clean Any dirt such a
9. nected correctly e USB adapter works in order Notes A USB adapter i e USB Serial Port Convertor is an optional accessory 35 TROUBLE SHOOTING How to verify your glossmeter A glossmeter is a kind of metrical instruments It is important and necessary to keep its accuracy For this reason the meter must be verified in a period of time usually a year Then we recommend you to verify the glossmeter as follow e Send it to a public organization which is authorised by the government and able to perform the gloss verifying Send it to a manufacturer that produces glossmeters Purchase certified standards to verify the glossmeter by yourself Note We also provide some models of Standards for gloss verifying as below MG268S H high gloss MG268S M medium gloss MG268S L low gloss 36 WARRANTY Limited Warranty And Technical Support e The limited warranty period is one year commencing on the date of purchase If your e meter needs service carry it to the local reseller or contact us at http www ksj cn for repair e We provide spare parts anytime for distributors and customers The inquiries on the gloss measurement may be directed to support ksj cn We also provide glossmeter customizing for a special application Notes e The meter should not be taken down at will in order to avoid precision destroying and maintaining difficulty f the breakdown is caused by taking down or inap
10. ore clearing Help AContents The contents of help AAbout KSJ Data Operator About the copyright and version of KSJ Data Operator and other informations 31 USING SOFTWARE Tool bar Current Data Equivalent to the corresponding menu command Historical Data les Equivalent to the corresponding menu command Print amp Equivalent to the function button of print Print Equivalent to the corresponding menu command Wi Function Button Delet Button To delete selected data shown in the Data Area permanently Delet All Button To delete all data shown in the Data Area permanently Excel Button To export data to an Excel document Print Button To make a printout 32 TROUBLE SHOOTING Wi Errors in self diagnose and self calibration When the meter is turned on with the Holder the warning message on right hand side may come out It says something would be wrong Please check ane settle the troubles in turn ia Clean STD Clean the Calibrating Standard Observe the surface of the Calibrating Standard against light If any dirt such as dust fingermarks steam and filth is found it should be cleaned gently with lens paper or a piece of soft cloth dipped in absolute ethanol Some abrasion and damage on the surface will change its verified values If so please contact the manufacturer to deal with z RetHolden Setthe main unit into the Holder Only when the ma
11. ory By menu operation you can browse the data in memory MAIN CUNCTIONS eDeleting defective measurements By pressing Measuring Button for two seconds or more the measurement displaying on the Display Window will be deleted This function is only effective in current group RS232 port 9 pins Through this series port MG6 F2 can communicate with a PC ePractical and friendly software KSJ Data Operator is not only friendly but practical It can help you to upload the data from MG6 F2 preset the measuring conditions process data and make a printout export the data to an Excel document eLow power consumption MG6 F2 needs only 1 2v to 1 5v DC power supply You can choose a piece of AA battery which may be alkaline or rechargeable An alkaline battery will support more than 20000 measurements ePrompt for low battery and full memory e Automatic shutoff If no operation MG6 F2 will be turned off by itself in a preset time interval CONSTRUCTION Whole set of MG6 F2 Display Window Menu Wheel Front Shell Rear Shell Bat Chamber Cover CONSTRUCTION Main Device Measuring Button Rear Shell RS232 Port Mark For Location Incidence Direction Front Shell Measurement Aperture CONSTRUCTION Holder With Calibrating Standard Calibrating Standard Gloss Value Label Holder CONSTRUCTION Battery in Position Battery Chamber Cover Battery With Positive Pole Up AA o
12. propriate use we reserve the rights not to guarantee it free in repair 37 PACKING LIST Main Device Model MG6 F2 Holder With Calibrating Standard RS232 Cable KSJ Data Operator Carrying case User s Manual Tracable Certificate Note 1 Unit 1 Unit 1 Piece 1 CD 2 Piece 1 Piece 1 Piece USB Adapter is provided as an optional accessory 38
13. r LR6 Alkaline or Rechargeable Rear Shell Front Shell 10 MEASUREMENT Bl Turn on the meter Lay the main unit into the holder then push down the Menu Wheel to turn on the meter The infos of model and series number will be shown in the Display Window meanwhile the meter performs self diagnose and self calibrating After passing this procedure the display should turn to measuring mode the meter would be ready for operation Or else it shows as below The messages prompt you to confirm that 1 The calibrating Standard STD is clean 2 The main device is set into the holder properly 3 Recalibrating is required when environment temperature change is great In this case the meter needs some time to establish a balance of temperature before calibrating Notes e If the main unit don t lay into the holder it is possible to turn on the meter by pushing down the Menu wheel But it will skip the self diagnose and self calibrating e Battery installing can also turn on the meter directly 11 MEASUREMENT Measuring and measurement interface Remove the holder and lay the Measurement Aperture just against the position that you want to measure Then push the Measuring Button Within 2 seconds a measurement will be completed Meanwhile the result will be shown in the Display Window as below and stored into the memory automatically Notes e GES express that the current measuement is the th
14. s fingermarks dust steam and filth should be cleaned gently with lens paper or a piece of soft cloth dipped in absolute ethanol 14 MEASUREMENT e If memory is full of data a prompt would be shown as below in Display Window In this case measuring operation will be in order but the results can t be stored into memory any more It is better to upload the data in memory to PC and clear the memory e When a battery runs out the following message will be shown Please replace the old battery with a new one 15 WARNING AND NOTICE A The whole set of the meter should be kept in dry and non corrosive environment under the temperature between 10 C to 60 C A Although the exterior parts of the meter are made of good quality plastic they may not resist some chemicals especially some strong solvents such as acetone and so on A If the meter is not in use please lay it into the holder A When moisture condensation occurs you may be unable to make a correct measurement A To avoid damage of the meter due to leak of corrosive liquid we strongly recommend you use a high quality battery A After turning off the meter will be in a sleeping state which consume little power Even so itis strongly recommended to remove the battery when no use for a long time interval A When the battery run out Low Battery will appear on the Display Window replace the old battery with a new one at once A For environment dispose the
15. u Wheel to confirm And then it will return to the measurement interface 23 MENU OPERATION iocur submenu Enter the menu turn the Menu Wheel to set a number of measurements in a group and confirm Then it will return to the measurement interface automatically Note The range is between 1 to 99 24 USING SOFTWARE Wi Brief introduction KSJ Data Operator is a simple software for data processing Using it we can perform a communication between MG6 F2 and a PC and upload the data of measurements Then we can process the data uploaded and export them to an Excel file or as a printout We can also operate on a PC to set the measuring conditions for MG6 F2 and clear its memory Software installation and uninstall To use KSJ Data Operator you need the following e an IBM compatible PC with a CD ROM e Microsoft Windows XP or later versions The software is on the CD that comes with MG6 F2 The procedure of intallation and uninstall is same as a normal software and it is unnecessary to be described here 25 USING SOFTWARE Wl How to connect between MG6 F2 and a PC There are two connecting cables for MG6 F2 to connect with a PC One is a RS232 Cable 9 pins and the other is a USB Adapter optional extra Using a COM port Simply connect one terminal to MG6 F2 and the other to a COM port on a PC Using a USB port Just connect the USB Adapter to MG6 F2 and a USB port on a PC 3 Note It is n