1. see the following figure with its band positioned outside and press it until it clicks For the band inserting direction refer to the arrow In the case a cable clamp is attached 3 Put the cable of the external speaker through the looped cable clamp band and pull the band for fixing the cable Cable clamp 4 2 Unit Installation The installation procedure for the sound output unit is explained using the GT1575 1 Power off the GOT 2 Remove the one extension unit covers of the GOT with a tightening torque of 0 36 to 0 48N m two places 5 When mounting any communication unit on the outer stage refer to the User s Manual for the GOT used When not mounting any communication unit on the outer layer stick accessory labels on the top of mounting screws 2 places to cover the top of them in order to avoid receiving electrostatic Keep the connector cover and label see the following figure fixed Accessory labels Connector cover Uo Sticker Precautions for connecting external speaker Do not connect or disconnect the cable of the external speaker during sound outputs Do not connect any devices other than external speakers to the sound output unit Removing sound output unit When removing the sound output unit tilt A PULL of the unit and remove the unit so as not to break the connector Cable clamp 1 Pulling out the cable clamp band The cable clamp band can be pulled out
2. after cable treatment Pull out the band with pressing the tab of the cable clamp outward using a driver etc 2 Removing from sound output unit The cable of the external speaker can be removed even though the cable is fixed with the cable clamp Remove the cable clamp by pressing it in both directions arrow A Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 B
3. MITSUBISHI GT15 Sound Output Unit User s Manual GT15 SOUT Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 SOUT U MODEL CODE 1D7M68 IB NA 0800383 F 1106 MEE GRAPHIC OPERATION TERMINAL GOTioo9o0 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct In this manual the safety precautions are ranked as DANGER and DESIGN PRECAUTIONS CAUTION Do not bunch the control wires or communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100mm 3 94 inches otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doin
4. ct in a place except for home Packing List After unpacking the box check that the following products are included Model name Product name Quantity GT15 SOUT Sound output unit 1 7 Mounting screw set 2 pieces of 1 screw 2 pieces of label Cable clamp set 1 1 OVERVIEW This User s Manual describes the GT15 sound output unit hereinafter referred to as the sound output unit With installing the sound output unit the GOT can be connected to a speaker with amplifier hereinafter referred to as external speaker When using the sound output unit set the Communication Settings For the setting refer to the User s Manual for the GOT used 2 SPECIFICATIONS The performance specifications of the sound output unit are indicated below The general specifications of the sound output unit are the same as those of the GOT Refer to the User s Manual for the GOT used for the general specifications of the printer unit Item Specification For connecting external L R speakers 1 channel for each speaker 2Vp p 0 4mW for rated load 10kQ Sound output terminal Applicable jack 3 5 stereo mini jack straight type GOT1000 Series Connection Manual Windows WAV format 8 000KHz 16 bits CAUTION i i i s iets ete cleaning always shut off GOT power externally Microcomputer MODBUS Products SH 080871ENG Playable file mono 8 secon
5. ct it to string shock A module damage may result Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the unit DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User s Manual for the GOT used as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Manuals The following shows manuals relevant to this product Detailed Manual Manual number Manual name Model code GT16 User s Manual Hardware SH 080928ENG Sold separately 1D7MD3 GT15 User s Manual SH 080528ENG Sold separately 1D7M23 Compliance with the Radio Waves Act South Korea This product complies with the Radio Waves Act South Korea Note the following when using the product in South Korea OIE 898 AS HUHS BOW LE ASHE 0 SS FASHA HHA PAM ASAI ANBote AS SHO g Suc The product is for business use Class A and meets the electromagnetic compatibility requirements The seller and the user must note the above point and use the produ
6. ds sound file eee i ee ae a a ae a ie ee X Not doing so can cause a unit failure or malfunction Peripherals for GT ee separately 1D7MC5 Internal consumed 0 08 1 Indicates that incorrect handling may cause a inl a can cause the GOT to drop short circuit or P y current DC5V iti ing i malfunction 7 F i DANGER leer hada oer l Overtightening can cause a short circuit or malfunction due to Relevant Manuals Weight 0 07kg 0 154Ib Including cable clamp i l the damage of the screws or unit mi Indicates that incorrect handling may cause I Do not disassemble or modify any unit For relevant manuals refer to the PDF manuals stored in the CD l A CAUTION iti ingi j l This will cause failure malfunction injuries or fire ROM for the drawing software used I hazardous conditions resulting in medium or Inj 3 l slight personal injury or physical damage Do not touch the conductive areas and electronic parts of this 2007 MITSUBISHI ELECTRIC CORPORATION B aibi a Sate a a i al S a Se i i eS i unit directly Doing so can cause a unit malfunction or failure Compliance with the EMC and Low Voltage Note that the A CAUTION level may lead to a serious accident Directives according to the circumstances Always follow the precautions of both levels because they are impor ee i ee es tant to personal safety nes A Please save this manual to make it accessible when required and Low Hle E E nee eee fih always forward it to the end use
7. g Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan June 2011
8. g so can cause a malfunction CAUTION Use this unit in the environment that satisfies the general specifications described in the User s Manual for the GOT used Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAUTION Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction STARTUP AND MAINTENANCE PRECAUTIONS lt gt DANGER CAUTION Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Do not drop the module or subje
9. r SQUIPMENL TEET 1o orme y General Description included with the GOT used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the GOT 4 Tighten the mounting screws of the sound output unit Warranty 3 PART NAMES AND EXTERNAL DIMENSIONS GOT main unit 4 2 ae S _22 Unit mm inch 0 87 The above figures show the external dimensions after installing the cable clamp Dimensions of X when mounted to the GOT GOT GT16 GT15 15 19 5 0 77 21 0 83 12 1 18 0 71 18 0 71 10 4 21 0 83 21 0 83 8 4 23 0 92 23 0 92 5 7 23 0 92 23 0 92 Unit mm inch No Name Description Mounting screws fixed with the 1 Mounting screw front communication unit or GOT Extension connector installed to a 2 Interface connector front extension unit or the GOT Extension connector to which a 3 Extension connector back extension unit is installed 4 Cable clamp For cable treatment Terminal for connecting a cable of 5 Sound output terminal external speakers 6 Rating plate 4 INSTALLATION PROCEDURE 4 1 Cable Connection 1 Connect a cable of an external speaker to the sound output unit 1 Cable of external speaker 2 Attach the cable clamp to the unit Be sure to attach the cable clamp to section A
10. razil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang don