User Manual - PiSector Home Security Alarm Systems

image

Contents

1. stands for default setting 2 Alarm delay is not workable for smoke detector gas detector or emergency button That is even though this system is set as alarm delay triggering of the mentioned sensors will cause immediate alarm without delay 3 In alarm delay state if any of the door sensor PIR sensor or wired sensor is triggered the siren will ring once per 5 second After the delay time the siren will keep ringing consecutively and the panel will send SMS and make alarm call 4 For the above phone operation one beep shows your input Vi successful a long beep shows the sentence you input is successful two short beeps shows your input is failed you should try again In the above SMS operation you will receive a reply message for confirmation after you send the message command to the base the replied message for example Disarm Sms ON Phone ON Siren ON Center Tel OFF Arm Center Tel OFF Disarm Center Tel OFF You will know the working state of the base then arm disarm or alarm Remote controllers The remote controller has four buttons 1 Out Arm Press the Out Arm button on the remote controller the STATUS indicator on the main panel flashes in orange 10 seconds later it will turn green with slow flash The system enters Out Arm mode and all the detectors will be in working status 2 Home Arm Press the Home arm button the STATUS indicator o
2. accessory and the main panel and adjust the position 3 Code it to the main panel
3. 950001 Save the 1st alarm phone number 13905950001 into the base 2 There are 7 default SMS contents in the base but you can change it When the wireless detector in zone 01 to 05 is triggered the default SMS content will be Wireless Activated X X can be 01 to 05 For example if detector in zone 01 is triggered the SMS will be Wireless Activated 01 When the wireless detector in zone 06 to 16 is triggered the default SMS content will be Wireless Activated X X 06 16 When the wire detector is triggered the SMS message will be Wire Activated X X 1 3 for port 1 to 3 alarm 3 You can send SMS commands to rewrite the above 7 kinds of SMS contents every SMS cannot excess 24 English characters 123456 8X SMS content X 1 to 5 For example Rewrite the 1 SMS content into Middle door open 123456 81 Middle door open Rewrite the 6 to 16 SMS content into Middle window open 123456 86 Middle window open Rewrite the wire detectors SMS content into Back window open 123456 87 Back window openi IV Test the host alarm When you start the base if the base is in Disarm status the signal LED keep still green you can use controller to change the base into Arm status or you can send SMS 123456 1 1 to the base to change the base into Arm status the signal LED will change to flashing green 1 Under Arm status with green LED on any port of input 11 12 13 short circuit or d
4. Wireless GSM Alarm System GSM 01 ww Ny Q User Manual Profile For a better understanding of this product please read this user manual thoroughly before using it 10 11 12 13 14 15 Features GSM 900 1800 1900 bands can be used all over the world 3 zones for wired detectors and 16 zones for wireless detectors Set arm disarm emergency alarm by remote controller Set arm disarm monitor output by calling the host Set arm disarm monitor output by sending SMS Monitor environment on the spot Voice and message alert 5 group phone room number 1 group alarm monitor center phone 2 group phone to report alarm and non alarm status Can program 7 group alarm messages Easy to set ON or OFF for every wired or wireless detector 1 relay output to trigger camera when alarm 2 output for home appliances connection lamp cooker air condition SMS alert for external power failure or recovery Built in battery ensures normal work even power failure Il Installation 1 Host a Insert SIM card in alarm system Press the yellow point on the unit with a pencil tip or other tools SIM card tray will come out Put the SIM card into the tray and make sure the Metal contacts of the card to be downwards and then push the tray back Before inserting SIM card in the alarm unit using a regular mobile phone do the following steps Set PIN code request to off Delete all stored numbers
5. atus LED light on panel will be red Push the reset button for one second the status LED light will light up in orange for 20 seconds This is code learning mode of inner defense zone You can trigger the sensors or detectors the LED will flash in red to show it is coded successfully into inner defense zone For above operation the host will exit code learning mode 20 seconds later automatically and enters into working mode the light on panel changes to orange to search for GSM network then to green Note If there were 4 wireless sensors in the host they stand for zone 1 to zone 4 and then the new added sensor will be 5th zone in the host VIII Delete detectors In case of the coded sensors or detectors are lost you can delete the coded information of these detectors so that they can not control your alarm system Keep pressing the reset button then power on the system One beep sound or LED flashes shows reset is successful All registered detectors have been deleted from the unit You can register them again with the above mentioned procedures System reset will not change the SMS message Basic Kit Main Panel 1 pc Wireless PIR detector 1 pc Wireless door gap sensor 1 pc Remote controller 2 pcs Antenna 1pc Mini wired siren 1 pc Power adaptor 1pc User manual 1pc The following sensors are optional a Wireless Outdoor Siren with flash Signal Rep
6. b Connect the antenna Screw the antenna to the unit carefully do not over tighten the nut or leave it too loose c Connect the power supply Plug the alarm system into power and turn on the power switch The signal status LED on the unit will turn red and last for 20 seconds This shows it s waiting for wireless detectors to be coded into the unit Then the status LED will turn orange with flash indicating the unit is checking the SIM card and searching for GSM network After checking if the LED changes to green with slow flash it shows phone numbers have been saved in the unit and the unit is now in Arm status If the LED keeps in green it means phone numbers have not been saved in the unit and the unit is in Disarm status you can call in or send SMS to program the phone numbers LED status explanation LED LED Status System working status Hasn t turned on the switch hasn t connected the power no power in built in POWER battery power supply is normal Ready to code wireless sensors Power Orange flash slowly Check SIM card and search GSM network Green flash slowly SIM card and GSM signal are normal have on y stored numbers in SIM card in arm status ST Gren have not stored numbers in SIM card in disarm status AT Red flash slowly In alarm status US Red flash quickly Remote controlled by SMS commands or Normal phone working Green Disarm Green flash slowly O
7. eater Wireless keypad 3 fa C PaO Glass Sensor Panic Button Remote Controller d4 A a p Wireless Smoke Gas Detector Wireless Pet Detector Immune PIR Detector Optional sensors detectors are packed separately You can choose according to your specific requirements Typical house configuration External Sirens Door window Garage Smoke J PIR Movement Detector Detectors TECHNICAL PARAMETERS Main Panel Static current 20mA Power 9V 12V DC Working temperature 100 40 GSM 900 1800 1900MHz band Receiving code ASK Frequency 433MHZ Wireless distance 100 M Wireless detectors 16 Wire detectors 3 Wireless Gap Detector Door Window Contact Power Supply DC12V inner 7 4V battery Static Current lt 20 uA Transmission Current 15mA Transmission Frequency 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Internal Distance 15mm Working Condition Temperature 100 40 Humidity lt 90 rh Wireless PIR Detector Power Supply DC9V inner 9V battery Static Current lt 100 uA Transmission Current 20mA Transmission Frequency 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 O 40 Humidity lt 90 rh Remote Controller Power Supply DC 12V 8 4 Inside A23 DC 12V dry batte
8. isconnected or any wireless detectors has been activated or you press the emergency key on the controller the alarm system will send alarm information by SMS and dialing out stored telephone numbers 2 It will send SMS before dial alarm phone numbers If the SMS function has been closed or limited it will only dial out the preset telephone numbers You can make them disarm with remote controller 3 When there is alarm it will dial out phone numbers you can answer the phone not need input password to operate it press 3 1 to start the siren and press 3 O to stop it press 4 1 to listen in and press 4 O to stop it press 93 1 to talk with the spot and press 93 O to stop it 4 When there is alarm it will dial out phone numbers you can answer the phone not need input password if you do not want the unit to dial next phone numbers just press 1 1 or 1 2 to re turn the unit into Arm status 5 When there is alarm you can use the controller to change the base into disarm status when you are in nearby can control the situation 6 When the external power is cut off the system will send SMS Power changer off to inform When the external power recovered the system will send SMS Power changer on to inform V Control the host 1 Send message to the host phone number SIM Card number Send message to the unit password 123456 add the following commands to control the unit 2 Call the host phone numbe
9. ist should use it with caution O3 SPEAKER This port is for voice output it can be connected to the speaker The other port of the speaker is to connect to ground You can control it by call in or send the SMS RELAY1 RELAY2 These two ports will close 3 minutes when alarm happens You can use these two ports to start the power supply of the camera when alarm happens also you can disable this function by setting command 16 1 you can also make this relay close or open anytime by sending SMS or dialing 94 1 or 94 0 LAMP AC 220V MAX 100W C LILI a e oG lo O DC12V LM o 00201 I b Ii SIM RESET OFF ON ANT Wiring Explanation For home appliance control for special order The controller box has four wires i Two yellow AC 220 wires to be connected with Home appliance ii GND 12V DC wires to be connected with a 12V DC Power supply NOTE lt Try to install the main panel in the center of defense zone and pull out the antenna to get longer wireless receiving distance lt Installation position should be far away from huge metal objects and wireless interference 2 Door sensor Door sensors are used for detecting the status of open and close of windows and doors It will detect it and send the signal to main panel 1 3 Tear apart the double side adhesive tape on the magnet and the transmitter Then adhere them t
10. n the main panel flashes in orange 10 seconds later it will turn green with fast flash Detectors inside the house in inner defense zone will not work only the detectors outside the house in outside defense zone will work so that people inside can move freely but others who break in from outside will trigger the alarm 3 Disarm Press Disarm button the system will enter into disarmed status the STATUS indicator on the main panel is green 4 Emergency When there is an emergency press the Emergency D button on the remote controller the system will alarm immediately no matter it is in arm or disarm status Vil Add more detectors You can add new sensors or detectors such as wireless door sensors PIR Sensors gas and smoke detectors into the unit 1 Add sensors ready to work when you set both Out Arm and Home Arm When the GSM host begins to be powered on the status LED light on panel will be red for 20 seconds this is code learning mode You can trigger the sensors or detectors and the red LED will flash to show it is coded successfully into the host The coding mode ends 20 seconds later automatically and system enters into working mode status LED light on panel will change to yellow then to green 2 Add sensors into inner defense zone Detectors in this zone are ready to work when you set Out Arm and will not work when you set Home Arm When the GSM host begins to be powered on the st
11. ntly wireless zone 1 16 wire zone 21 23 39 Set disarm of zone independently wireless zone 1 16 wire zone 21 23 50 show preset phone numbers in the host SMS command applicable only 51 First group phone 52 Second group phone number 0 l1 5bit number 0 l1 5bit 53 Third group phone 54 fourth group phone number 0 l1 5bit number 0 l1 5bit 55 Fifth group phone number 0 1 5bit 80 show preset SMS in the host 8 1 Wireless zone 01 82 Wireless zone 02 Message 0 24bit Message 0 24bit 83 Wireless zone 03 84 Wireless zone 04 Message 0 24bit Message 0 24bit 85 Wireless zone 05 86 Wireless zone I Message 0 24bit Message 0 24bit I 06 16 8 7 Wired zone Message 0 24bit 90 Show Output status in the host 91 1 Set Output 1 to high 91 0 Set Output 1 change to low 92 1 Set Output 2 to high 92 0 Set Output 2 change to low 93 1 Set talk to the host 93 0 Set talk to the host available Output 3 unavailable Output 3 94 1 Set Relay to be 94 0 Set Relay to be disconnected connected 95 1 Set alarm when input 1 95 0 Set alarm when input 1 open connect to GND 96 1 Set alarm when line 96 0 Set alarm when line input 2 input 2 open connect to GND 97T 1 Set alarm when line 97 0 Set alarm when line input 3 input 3 open connect to GND Note 1 Inthe above table
12. o the appropriate position Magnet should be near to the side of transmitter with indicator The two should align with each other and the distance should not exceed 10mm Please plug out the antenna for better signal If the low power indicator is on please change the battery in A less than 10mm Wireless PIR detector PIR detectors are used to detect the movement within a certain range lt gt Fix the adjustment bracket on the wall with the provided screws and attach the detector to the bracket It is recommended to mount it at a height of 2 2 2m above the floor Effect of the PIR detection is best when the detection direction is in 90 angle with the walking direction of the intruder Choose the most suitable installation place and angle according to actual situation and taking the following installation diagram as reference to ensure the detection effect is best Please do not fix it under direct sunlight or other strong lights and also keep it away from places with frequent strong air stream If the low power indicator is on please change the battery window ad door Set alarm phone numbers You can send message to the unit to set 5 alarm phone numbers and 7 alarm SMS The command format password operation code content 1 Save the alarm phone numbers 123456 5X alarm phone numbers X 1 to 5 Save 5 group alarm phone numbers into the base For example 123456 51 13905
13. r SIM Card number Call in the unit and enter password 123456 then input the following command to set the base Commands table Com Function Com Function 1 1 Out arm 1 2 Home arm all detectors work part detectors work 1 0 Disarm all detectors not work 3 1 Siren Sounds 3 0 Stop sounding immediately 4 1 Start listen in Call the 4 0 Stop listen in alarm panel and then Call the alarm panel and then input this command input this command 11 1 Need siren sound when 11 0 No siren sound when alarming alarming 12 1 Send SMS when 12 0 No SMS when alarming alarming 15 1 Dial phone number 15 0 Just alarm and no dialing when alarming 16 1 Relay does not close for 16 0 Set Relay close for 3 Min 3 Min when alarming when alarm 21 1 Siren rings when 21 0 Siren off when pressing out pressing out arm arm button button 22 1 Siren rings when 22 0 Siren off when pressing pressing home arm home arm button button 23 1 Siren rings when 23 0 Siren off when pressing pressing disarm button disarm button 27 00 Arm delay 00 99 delay time default 10sec 99 28 00 Alarm delay 00 99 delay time default 00 99 30 show the arm and disarm status of every zone SMS command applicable only 31 Change password Enter a new password 1 6 bit 38 Set arm of zone independe
14. ry Static Current 0 Emission Current lt 15 mA Emission Frequency 433 0 2 MHz Emission Speed Ts1 second Emission Distance no obstacle 80m Working Environment Temperature 10 C 40 C Humiditys90 FAQ Problems Cannot alarm by phone Causes 1 Hasn t armed 2 Less than 30 seconds after arming 3 Set wrong phone number 4 The two parts of door window sensor is installed too far from each other 5 Haven t activated PIR 6 Hasn t checked code Solutions 1 Arm the unit 2 Operate after 30 seconds 3 Set the number again according to the manual 4 Adjust the installation place of the door sensor 5 Activate the PIR Check code again 9 Remote controlling distance is too short and the light indicator is not on bright enough 1 The battery of remote controller is rusty 2 Low battery Clean the rust Change battery D Light indicator of door sensor and PIR is always on Dial alarm number slowly Low power battery The main panel has stored other numbers Change battery Set it again according to the operation manual The main panel cannot receive signals from the accessory 1 Low power battery in the accessory 2 There is block between the control panel and the wireless accessory or the distance between them is too far 3 The accessory has not been coded to the panel 1 Replace the battery 2 Pull out the antenna of the
15. ut Arm Green flash quickly Home Arm On Can monitor the scene when alarming but MONITOR the siren will not ring l off Can not monitor the scene when alarming but the siren will ring On The siren will ring when alarming ALARM Off The siren will not ring when alarming d Configuration of the alarm unit There are 10 connect ports at the top side of the unit GND SIREN RELAY1 RELAY2 03 SPEAKER 02 01 13 12 11 GND power ground SIREN Connect the black wire to GND port and the red wire to siren port 0 Black GND e II a oO DC12V M 003020 BRK SIM RESET OFF ON ANT 11 12 13 Connect wired sensors Three inputs are available to connect wired sensors Inputs are independent and not coded as different zones When these sensors are triggered the unit will sent SMS message Wire Activate 1 3 Sensors can be NO normally Open or NC normally Close type More than 1 sensor can be connected to one input connect their alarm contacts in series The number of the sensors is not limited as long as the total resistance is under 220 ohms Wired sensors Onn mum sO N DC12V M o 00302013121 SIM RESET OFF ON ANT 01 02 These 2 ports for output you can call in or send SMS to set them If output of these goes high the light of OUT 1 or OUT 2 will light on the panel non special

Download Pdf Manuals

image

Related Search

Related Contents

STAGE SCAN - Clay Paky  Petit mode d`emploi  Modulation format comparison in PMD  EPSON EMP-765/755/760/750 クイックリファレンスガイド  bd-7000 istruzioni per l`uso  Dicota Harbour 2.0  Radio Shack 26-234 User's Manual  JVC V.NETWORKS VN-C10 User's Manual  Kit Manual - Alere Technologies GmbH  Motorola H17 Bluetooth Headset User Manual  