Home
DAVENHAM STEAM SHOWER ENCLOSURE
Contents
1. Fan button in for 3 seconds to switch the display from Celsius to Fahrenheit Image 7 8 emis Ge Steam ON OFF Ki L Push the Steam ON OFF button to turn the steam function on Image 9 When the steam function is on the steam ON OFF symbol flashes The steam function is automatically turned off when the cabin temperature reaches 4 degrees higher than the set temperature and on when the temperature drops to 4 degrees below the set temperature customer service 1 866 855 2284 ei SIGNATURE HARDWARE Signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 16 CONTROL PANEL A MP3 Press the MP3 button to select the MP3 function Adjust the channel to match the channel set on the MP3 emitter Hold the MP3 button in for 3 seconds to set the channel and volume FM Radio ON OFF Push the FM Radio ON OFF button to turn the radio function on When the radio is on the FM Radio ON OFF symbol flashes The channel will default to that last selected gt A Volume Channel Push the Volume Channel button with the radio on Image 12 to adjust the volume Push the 7 A buttons to make adjustments as necessary To change the channel press the button twice when the radio is Image 12 on Image 13 Push the Ki Al buttons to scan Image 13 customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Davenham Steam Shower Enclosure Installatio
2. MANUAL LCD Display zech Fahrenheit Celsius Temperature Temperature Indicator T Timer Setting FM Radio Function FM Radio Volume FM Radio Channel Chromatherapy ON OFF 10 Fan ON OFF 11 Steam ON OFF 12 Power ON Indicator 13 FM Radio Channel 14 MP3 ON OFF 2 3 A 5 6 T 8 9 A ei SIGNATURE HARDWARE y QY E E H Pa Ka ei II customer service 1 866 855 2284 signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 13 CONTROL PANEL Steam Cabin Control Parts zech LCD Display Control Panel Water Diverter Steam Outlet Hand Shower Set Oo dO N O a A O N 10 Steam Generator Cleaning Liquid Jet ei SIGNATURE HARDWARE Steam Temperature Sensor Water Volume Adjustment Water Temperature Adjustment Back Massage Jet Steam Cabin Control Panel Power ON OFF Steam Temperature Setting Steam Timer Setting Fan ON OFF Chromatherapy Steam ON OFF MP3 Radio Volume Channel Radio Settings Adjustment Adjustment customer service 1 866 855 2284 signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 14 CONTROL PANEL Push any button to light the display Image 1 Push the Power button to turn the system on Image 2 and off When the power is turned off the display and background light shuts off immediately while the drain valve for the steam gen
3. DAVENHAM STEAM SHOWER ENCLOSURE INSTALLATION AND USER MANUAL KS AS DN ma Jm CONTENTS Steam Shower Enclosure Installaton eee 2 Technical INfOPMMAUOM BEE 2 Sieten Wlan 2 PAS SOIMONY TEE 3 TOOIS ANG WE EHNEN EEN 3 VS Cel AON EE 3 Safety INTOrMatiOn icc 23 ccc ss hac Hele ee i eee 10 Steam Cabin Technical SGpechhcatons eee 11 n UCI EE 11 Bee MEI EE 11 CONE Ol AINE lives EE 12 Steam Generator Cleanmg 16 lee Ee e d du LE 17 customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 1 STEAM SHOWER ENCLOSURE INSTALLATION Before you begin read the following installation and care instructions Observe all local plumbing building and electrical codes Unpack and inspect the product for any shipping damages If you find damages do not install Contact Customer Service at 1 866 855 2284 If you need assistance or have questions while installing your shower enclosure contact Customer Service We recommend that all plumbing and electrical rough in work be completed by a professional prior to shower enclosure assembly Signature Hardware accepts no liability for any damage to the enclosure walls floor or for personal injury during installation TECHNICAL INFORMATION e 220 volt 20 amp GFCI breaker e Line 1 line 2 and ground 1 dedicated line for steam e The size of breakers and wire gages is determined by local state and nat
4. alls with assembly screws and blocks provided ST4 50 flat head tapping screw front door frame 4 Attach the hand spray slide bar and shower basket M4 25 screw black O ring technical panel gt M4 gasket J M4 gasket a black O ring small copper meson D M4 25 screw i small decorative cap chained holder ei SIGNATURE HARDWARE customer service 1 866 855 2284 signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 4 5 Drill holes in Wall A and Wall B and insert the wall anchors inflating nut Attach the door frame to the wall with the ST4 x 30 mm tapping screws press block ge nut a 30 mushroom head tapping screw is 6 Secure the door frame to the shower tray ST4X25 flat head tapping screw q lower track Shower tray en customer service 1 866 855 2284 signaturehardware com a e ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 5 7 Attach the right wall panel to the shower tray ST4X16 round head tapping screw ST4X25 flat head tapping screw 8 Attach the back wall panel to the shower tray ST4X25 flat ei ad tapping screw ST4X16 round head H tapping screw customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 6 9 Atta
5. ch the left wall panel to the shower tray L_ ST4X16 round head tapping screw a ST4X16 round head tapping screw 10 Install the door panels F type block A ST4X20 flat head tapping screw customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 7 11 Attach the top cover to the shower frame amp copper meson ST4X16 flat head tapping screw small decorative cap 12 Connect the flexible water feed tubes and electrical wiring to the corresponding outlets jet pipe GEN Be XQ AS 8 1 exhaust fan 8 2 chromatherapy lamp 8 3 speaker 00000 e ez CH Z Ceiling shower pipe CS o ei SIGNATURE HARDWARE customer service 1 866 855 2284 signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 8 13 Install the shower door gasket hinge back cover movable glass door gasket main body 14 Attach the door handle to the shower door customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 9 15 Install the plastic sealing and magnetic strips according to the drawing specifications to prevent leakage roof mag
6. erator remains running for one minute Ir Steam Temperature Setting The default steam temperature setting is 113 degrees To adjust the temperature push the Steam Temperature Setting button Image 3 until the desired temperature is reached When the cabin temperature reaches 4 degrees above the set temperature the steam generator automatically shuts off When the cabin temperature reaches 4 degrees below the set temperature the steam generator automatically turns on L Steam Timer Setting The default steam timer setting is 45 minutes To adjust the timer setting push the Steam Timer Setting button Image 4 until the desired time is reached The system automatically shuts off at the end of the specified time Image 4 customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 15 CONTROL PANEL Chromatherapy The Chromatherapy button controls the color of the chromatherapy lights The chromatherapy symbol on the LCD display flashes when the chromatherapy lights are turned on Image 5 Press the Chromatherapy button to adjust the turn the lights on and off and to adjust the lights as desired e E d en f b t Igi H i s K R 4 E p E E d cE 4 T wl fy H E 3 i eh Le Y3 Fan ON OFF E The Fan button turns the ventilation fan on and off When the fan is running the fan symbol on the LCD display flashes Hold the
7. hut off Turn the water supply valve on if necessary e Remove the scale on the water level sensor and clean with warm water and a mild detergent Replace the scale if it appears to be broken e Make sure that the temperature setting is not lower than the room temperature Reset the temperature if necessary e Replace the thermal switch inside the heater e Ifall parts appear to be clean and in working order and problems persist it may be necessary to replace the heater If water does not stop being added to the steam generator e Replace the water inlet valve e Remove the scale on the water level sensor and clean with warm water and a mild detergent If problems persist it may be necessary to replace the scale If the unit will not turn ON e Replace the heater or thermal switch If water is leaking from the valve e Replace the valve seal If the water flow volume is low e Impurities in the water supply can clog the filter resulting in low water flow To remove clogs remove the filter and rise with warm water customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 19
8. iate GFCI should be provided by the installer and should be tested on a routine basis e To test the GFCI push the Test button The GFCI should power off Push the Reset button to restore the power If the GFCI fails to operate in this matter it is defective e Ifthe GFCI fails to provide power to the shower enclosure and a ground current is flowing the user could potential ly incur an electric shock Do not use the shower enclosure and repairs performed by a qualified electrician before using e Agreen colored terminal or wire connector marked G GR or Ground is provided within the front column To reduce the risk of electric shock connect this terminal or connector to the grounding terminal of your electric service or supply panel with a connector equivalent in size to the circuit of the conductors supplying this equipment To reduce the risk of injury e The wet surfaces of steam enclosures may be slippery Use care when entering or leaving e The steam head is hot Do not touch the steam head and avoid the steam near the steam head e Prolonged use of the steam system can raise internal body temperature and impair your body s ability to regulate temperature hyperthermia Limit steam use to 10 15 minutes at a time until you are certain of your body s reaction e Excessive temperatures have a high potential for causing fetal damage during the early months of pregnancy Pregnant or possibly pregnant women should cons
9. ional codes as interpreted by the installing electrician PLUMBING REQUIREMENTS e This unit is equipped with hot and cold braided water supplies with 1 2 NPT pipe threads e Install hot and cold shut off valves with 1 2 male NPT pipe threads to connect to water supplies e Tighten all connections prior to installation e We recommend preparing the drain location with the shower enclosure base on site A drain pipe 2 in diameter is required hose can stretch 6 customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 2 ASSEMBLY TOOLS AND MATERIALS Level Screwdriver Silicone Sealant Caulking Gun Adjustable Wrench Drill Set Square Rubber Mallet INSTALLATION 1 The distance between Wall A and Wall B should be within 58 59 The distance between the Floor Drain and Wall C should be less than 23 Use a level to verify that the walls are perfectly straight Wall A Wall C Wall B mg Le Floor Drain 2 Set the shower tray in place Place a level on the tray and adjust the tray legs as necessary until completely straight Each leg should be touching the floor eg fixep after adjusting customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 3 3 With a drill insert the assembly nuts into Wall A and Wall B Attach the door frame to the w
10. n and User Manual 17 CONTROL PANEL Radio Settings Selecting and saving preset radio stations e Turn the radio on e Push the Radio Settings button twice to display the preset numbers 1 8 Image 14 e Scan to the desired station and hold the Radio Settings button until the appropriate preset number is displayed Finding a preset station e Turn the radio on e Push the Radio Settings button to scan through the preset stations STEAM GENERATOR CLEANING To clean the steam generator remove the cover from the cleaning liquid inlet Input 1L of mild detergent Turn the steam function on to fill the generator with water Before steam is released turn the steam function off Do not shut off the control system the system will drain the dirty water automatically after 60 minutes Repeat these steps to clean the steam generator every 3 months ei SIGNATURE HARDWARE Image 14 Leg e xw a d e CO customer service 1 866 855 2284 signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 18 TROUBLESHOOTING If the touch panel is not functioning properly e Check the connection from the control panel to the power box If the control panel and power box are properly connected and problems persist it may be necessary to replace the panel or box If the steam function is ON but no steam is being released into the cabin e Check to ensure the water supply valve has not been s
11. netic stripe on the movable door 309B seal E movable glass door fixed door i ovaie glaSs door movable glass door shower tray 16 Install the decorative trim pieces aa SS CG E 4 4 lt 5 CZ E E Be customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 10 14 Apply silicone sealant around the base of the shower Connect the steam drainage pipe to the floor drain LEN E 15 Install the shower grid and shower seat Allow the silicone sealant to dry for at least 24 hours before using your new steam shower CA NN Jim customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Davenham Steam Shower Enclosure Installation and User Manual 11 SAFETY INFORMATION e When using this unit basic safety precautions should always be followed e Children under the age of 16 should not be permitted to use the steam shower enclosure e Use this unit only for its intended purposes as described in this manual Do not use any additional attachments not recommended by the manufacturer e Never drop or insert objects into openings in the steam shower enclosure e The unit must be connected to a supply circuit that is protected by a ground fault circuit interrupter GFCI The ap propr
12. ult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory problems or diabetes should consult a physician before using the steam system e f using medication consult a physician before using the steam system as some medication may induce drowsiness or affect heart rate blood pressure and circulation Hyperthermia warning Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include dizziness lethargy drowsiness and fainting The effects of hyperthermia include e Failure to perceive heat e Failure to recognize the need to exit the steam shower e Unawareness of impending risk e Fetal damage in pregnant women e Physical inability to exit the steam shower e Unconsciousness WARNING The use of alcohol drugs or medication can greatly increase the risk of hyperthermia customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Davenham Steam Shower Enclosure Installation and User Manual 12 STEAM CABIN TECHNICAL SPECIFICATIONS Rated Power 3 0 KW Rated Voltage AC240V Rated Electric Current 16A Frequency 60 Hz Power Supply Location Wall Water Supply 2 NPT pipe thread hot cold water Water Supply Location Wall Diameter of Drainage Pipe 1 72 flex pipe Length of Drainage Pipe 39 USER
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 - DXアンテナ Copyright © All rights reserved.
Failed to retrieve file