User Manual Motion Detector Infra Garde 360 AP Acoustic
Contents
1. and ambient temperature the response may vary depending on the installation site floor heating hot environment etc Louvre clips to contain detection area Troubleshooting error light does not turn on cause amendment twilight adjustment value set too low check light fitting and lamp check mains power fuses detector triggers without reason light never turns off check detection area for errors draught animals heating may cause faulty switching detector is too sensitive reduce sensitivity contain detection area with louvre clips check distances to lamps heat reflection or direct light influence check vicinity for background noise and ad just microphone sensitivity connect RC element in parallel to transfor mers relays electric ballast turns the light on during daytime twilight adjustment set too high Electronic Control Induction in long installation wires if several detectors connected in parallel may generate a considerable capacitive current on the switched phase For electric loads using only a small control current such as staircase timer switches this may lead to permanent switching or general malfunctions In order to minimise the capacitive current an RC element may be connected in parallel to the load Alternatively a contactor which is more tolerant to capacitive currents may be installed before the load We recommend a maximum of four detectors connected in paral
2. User Manual Motion Detector Infra Garde 360 AP Acoustic Warning Any work on the main power supply must only be completed by trained specialists The product must be installed in accordance with installation guideli nes standards specific to your country Disconnect the 230V power supply before starting the installation process The device s power supply must always be fitted with a 250VAC 10A type C fuse in accordance with EN60898 1 The device must not be installed on conductive surfaces The device is suitable for indoor installation only Disconnect power prior to replacing a lamp Faulty lamps may cause a short circuit and thereby permanently damage the device To ensure the operational reliability of the detector keep a minimal distance of 1m to lamps installed on the same height level Lamps installed underneath the detector or in the detection area may impair functionality Keep away from heating devices In case of malfunction such as continuous lighting or false triggering please refer to the troubleshooting section on this page Function The detector reacts to the motion of heat positive or negative in relation to the environment If a person approaches the monitored area the device will turn on the connected light automatically If the person leaves the area the light will be switched off after the preset duration Short impulse 30 sec to 30 min The in built microphone extends the de
3. ange adjustment max approx 8 m diameter Technical Data Nominal power Switching power 230V 50Hz max 1000W 5A cos 1 max 250VA 1 25A inductive impulse 30 s to 30 min adjustable approx 50 to 70 dB Dimensions Time adjustment IP protection Microphone Twilight switch Detection area Connection of electrical loads High inrush currents will considerably shorten the lifetime of the detector s in built relay Please verify the technical data provided by the lamp or lumi naires manufacturer concerning inrush currents specifically with compact fluorescent fluorescent lamps electronic ballast etc in order not to over load the internal relay We recommend connecting a maximum of three to four motion detectors in parallel If the number of switching cycles is above average or in the event of increased inductive loads we recommend using the short pulse function on the motion detector and switching the load via an external staircase timer switch or contactor Detection Range frontal detection NOT SENSITIVE _ approx 50 max 8m I S tangential detection Qem SENSITIVE R S max 8m The 360 omnidirectional detection zone and the dense detection field gua rantee an optimal function The range depends on the installation height and walking direction high sensitivity when cutting or changing a switching seg ment Since the detector reacts to temperature differences between heat source
4. lay time while lights are still on as well as during a maximum 10 seconds after lights switch off The connected light will be turned on only when the ambient light value is below the adjusted value Installation Install the device at a height of approx 2 to 4 m away from heat sources trees and light reflecting areas Wire the detector as follows SENSOR N 230V AC 50Hz lz phase outer conductor L brown neutral neutral conductor N blue switching output switched phase outer conductor L red Screw and tighten the detector to the ceiling The device is operational after approx 1 minute from connecting to mains voltage Qa xt ru 30 C A eT VOICE TIME SENS LUX VOICE microphone Activate in built microphone to extend delay time during lights on without additional movement detection or visual contact max 10 seconds after lights switch off Each detected noise re triggers set delay time Middle position detects normal talking volume maximum setting detects whispers TIME Set up delay time for lights on time period after last movement detection Choose between impulse function for staircase switches 30s 1m 3m 5m 10m 20m 30m LUX twilight sensor Controls light value from which motion detection triggers lights on Moon symbol activation at night sun symbol activation during daytime TEST detection area check with short delay time SENS sensitivity detection range Detection r
5. lel Do not dispose of electrical appliances in your waste bin use the collecting point of your municipality or return the old device to your dealer approx 5 1000 Lux 360 8 m 143 x 70 mm IP20 indoors class ll