Home
PRODIGY - Breathalyzer
Contents
1. NOTE A Passive Test is only used for screening it checks for the presence of alcohol in a breath sample An accurate test result can only be obtained through use of a Standard Test with a mouthpiece NOTE Test records of the screen tests cannot be printed or stored is clear of alcohol so it does not alter the outcome of the breath sample test No Alcohol SOFTWARE FEATURES Passive Test Specific Test Settings Record Ed Number Ej Auto Print PRINT If you have a compatible printer use this section to set the number of copies printed a and if you want all readings to print automatically select b E Keyboard DATE amp TIME Set correct Date and Time Select Update to confirm CI Use MDY restart
2. Bi icon is 10 C 50 C Use within this temperature range wil Record No 00089 When the screen displays Please Blow take a deep breath and limit condensation from the subject s breath and ensure Use B or GJ to move to the next or previous record Date Jul 27 2011 blow towards the sampling cup until the BEEP tone stops an accurate reading is taken It is recommended that the operator observes the subject for approximately 20 minutes before administering the breath test This is to ensure the subject does not consume anything Following this procedure will ensure the subject s saliva Press the On Off button to move 10 records forward and press Test Mode Passive the Function button to move 10 records backward Test Result 0 000 Alcohol Detected or No Alcohol displays on the screen A passive test can be performed by selecting Passive whilst Driver Name Press the On Off button and Function buttons together to jump to the record needed First Jump to first Record End Jump to end Record 0 00 00 Jump to a specific record e g 0 01 00 means jump to record 100 0 92 00 means jump to record 09200 In order to download your data to a PC you must have the Prodigy PC software available from www alcosense com au the user is blowing Select Gio start another test If the screen shows Alcohol Present use a mouthpiece to perform a standard test so that an accurate BAC reading can be obtained
3. 0C0O 0CCCO8OGCCC0C00G9C9C8088GC90G0C808OO9CG8COOOOOOOO AlcoSense Qandatech PRINTER PRINT If a printer is to be used press the ON OFF button on the printer the indicating lamp should turn on If an alcohol breathalyser with a wireless print feature is used make sure the S N number on the printer is the same as the breathalyser if this is not working or the printer cannot receive a signal from the breathalyser please connect the breathalyser and printer with a cable To turn off the printer press and hold the ON OFF button on the printer INSERT PAPER Pull the handle When inserting a new roll of paper make sure glossy side of paper is kept close to indentation NOTE If nothing can be printed change the side of the paper and try again BATTERY LIFE High Capacity Lithium rechargeable batteries can print around 30 meters of paper The printer can also be powered through a car battery with a 6V cigarette cable In order to down load your data to a PC you must have the Prodigy PC software available from www alcosense com au STANDARD TERMAL PAPER SIZE 6cm X 1000cm Release lever ues eth On Off FE button Wr A wireless thermal printer can be used with the device Caution Only use Lithium battery provided ALCOSENSE PRODIGY QUICK START USER GUIDE ATTACHING A MOUTHPIECE e Tear the perforated section from the wrapper of a new mouthpiece Pull back the wrapper to expose half the mouthpiece Ens
4. Calibration Centre Andatech Corporation Pty Ltd PO Box 3038 Nunawading VIC 3131 1300 800 200 www andatech com au A www alcosense com au el D a T So Lic No QEC24924 version 11 440 2 Te SAI GLOBAL O andatech AlcoSense PRODIGY User Manual INTRODUCTION Thank you for purchasing an AlcoSense Prodigy The AlcoSense6 Prodigy is a state of the art instrument used to detect ethyl alcohol from a valid breath sample It uses an electrochemical fuel cell to measure the concentration of alcohol from the breath sample expelled from a human subject If alcohol is present a corresponding voltage is generated from the fuel cell which is proportional to the alcohol content of the sample provided by the human subject This voltage is then sent to the CPU and converted to the subject s BAC blood alcohol concentration which is then displayed PREPARATION Gently pull down the battery compartment cover to remove it Insert fresh alkaline batteries 4 x AA checking that the and on each battery are aligned according to the polarity diagram inside Carefully replace the battery compartment cover DIAGRAM EXPLANATION Disposable mouthpiece Button to remove mouthpiece Touch screen display On Off button External power connectors Stylus pen Function button WARRANTY The manufacturer warrants for 1 year from the date of purchase the product to be free from defects i
5. c drinks mouthwash medicines and drops as well as by belching and vomiting Rinsing your mouth with water or non alcoholic drinks does not substitute for an interval A person s blood alcohol concentration BAC can continue to rise for up to 2 hours after drinking alcohol If a caution results or a result is close to the designated BAC it is recommended to wait and retest after 20 minutes It can take 10 hours or more for a person s BAC to return to zero after a high BAC has been reached A further test should be carried out later in the day or the following morning Working temperature range of AlcoSense6 Prodigy 5 C to 40 C Storage temperature range of AlcoSense Prodigy 15 C to 65 C LIABILITY FOR PROPER FUNCTION OR DAMAGE The liability for proper functioning of the instrument is irrevocably transferred to the owner or operator in the event the instrument is serviced or repaired by personnel not employed or authorised by Andatech In such an event the warranty will be void E Keyboard Test Result 0 000 ADVANCED SETTINGS Only a qualified person is authorised to use these settings A password is needed E Keyboard iy AUTO OFF Select time limit to turn off the device automatically Select to confirm By TEST RECORDS PASSIVE TEST The optimum temperature range for operating the unit pera MU can be stored depending on the Attach a sampling cup to the sample port and select the
6. n workmanship or material excluding recalibration under normal use The manufacturer s obligation under this warranty is limited to replacing adjusting or repairing the unit if returned along with proof of purchase This warranty is void if the unit has been tampered with damaged or abused in any way To register your warranty online go to www alcosense com au warranty RECALIBRATION AND SERVICE The AlcoSense Prodigy uses a sensor to measure breath alcohol levels Depending upon the amount of alcohol registered by the sensor after a period of time it will require recalibration Andatech recommends the AlcoSense Prodigy is calibrated every 12 months or after 1500 uses For recalibration and technical support please contact us at Andatech Corporation Pty Ltd Hot line 1300 800 200 Website www alcosense com au PRODUCT REGISTRATION Register online at www alcosense com au warranty to extend your warranty by one year and receive calibration reminders Alternately complete this form and forward to Andatech Corporation Pty Ltd PO BOX 3038 Nunawading VIC 3131 Australia Product AlcoSense Prodigy Date of purchase 00 eeccccssecesccccecesseccsrcceoees Place of purchas6 ueeeiiio u Surname eceoeoeoeoooooeoooDeoooDDD O 0008000000000 OODDOODDDeDDO 2060900000 OGOOOoO Seoecooeeoooooooeoooooooooooooooooooooo o oo o OO OO OO O OOOOODoDo CCO0OO89OOOOOCDOOOCCC0CC9C99890080
7. n or of their level of intoxication or of their fitness to drive and in particular should not take any action in reliance on such information as the product can provide no more than an indication of alcohol on the breath If the user of this product makes any decision or takes any action based on the use of the product such decision or such action shall be at the sole risk of the user and neither the manufacturer nor the supplier assumes any responsibility for such decision or action In particular neither the manufacturer nor the supplier shall be in any way liable if the user of the product asserts that the product led them to believe they were fit to operate a motor vehicle and are subsequently found not to be so fit If the subject fails to give a valid breath sample the operator can either select Discontinue to confirm or can select Test Again to allow the subject to redo the test again A passive test can be performed by selecting Passive whilst the user is blowing Slide up the button underneath the mouthpiece to remove the mouthpiece MEASUREMENTS amp CONDITIONS FOR TEST Use a clean mouthpiece for each test Do not allow samples containing smoke tobacco or other chemical products to enter the unit as damage to the fuel cell can occur There must be an interval of at least 15 minutes after alcohol consumption as alcohol residue in the mouth may give a false reading Such residue may also be left by aromati
8. other test If the subject does not blow into the unit within 30 seconds the operator can either select Refuse to confirm the subject refused to do the test or can select Test Again to allow the subject to redo the test LG andatech EFFECTS OF ALCOHOL ON THE HUMAN BODY Alcohol is a central nervous system depressant This means it slows down the processes occurring in the higher centres of the brain resulting in such classical symptoms as loss of balance poor coordination of the eyes and limbs tunnel vision and an inability to be self critical with the result that affected persons genuinely believe themselves to be driving better and safer than they really are DISCLAIMERS This product must be used strictly in accordance with the instructions in this manual This product is intended to provide the user with an indication of alcohol on the breath However neither the manufacturer nor the supplier gives any warranty express or implied that the product can give any indication of blood alcohol level A person s BAC Blood Alcohol Concentration can only be accurately measured by the administration of a blood test This product only measures breath alcohol content which in turn only gives an approximate indication of blood alcohol concentration In these circumstances the user of this product should not rely on the information provided thereby as an accurate indication of their blood alcohol concentratio
9. uring the two small holes in the bottom of the mouthpiece are aligned with the sensor insert the notched end of the mouthpiece into the slot on the right of the screen Lower the other end of the mouthpiece until it snaps into place Discard remaining wrapper from mouthpiece COMPLETING A TEST e Hold down the on off button to switch the unit on e Select the top right icon to enter Specific Testing Mode e Take a deep breath and blow into the mouthpiece until the progress bar counts down from 100 to O then stop blowing e The reading is displayed on the screen THINGS TO REMEMBER Always wait a minimum of 15 minutes after your last drink before testing e NEVER take a sip of alcohol and blow immediately into the device e Ignoring these two points WILL cause damage to the unit that is NOT covered by warranty andatech andatech OPERATING INSTRUCTIONS STANDARD TEST WITH INPUT Attach a mouthpiece to the sample port and select the G icon Using the stylus pen select keyboard in the settings 1 then input information 2 If Keyboard is not selected the unit will move directly to test mode 3 Note 16 character maximum for each input When the screen displays Please Blow take a deep breath and blow until the operator advises The display will show a progress bar indicating 0 once a sufficient sample has been taken The test result will display a Select C to start an
Download Pdf Manuals
Related Search
Related Contents
Cables Direct B6ST-710K networking cable Leia completamente as Instruções antes de operar F 26237 OM, PP 518, 2012-06, EN, FR, NL, DE Definitive Technology DEFINITIVE'S REVOLUTIONARY BIPOLAR 30 User's Manual Viewsonic TD2240 touch screen monitor Sandberg HDMI 19M-19M 2m SAVER 10pac 58928_IT_NL_PT - Lidl Service Website Copyright © All rights reserved.