Home

USER MANUAL

image

Contents

1. 26 16 7 Customization function menu ACTIV i dEFAULt sess 2 17 Maintenance and repairs of small defects enn 28 Declaration Of CON OTT t DE Mee O 29 OPERATION MANUAL 3 1 General description BLM series scales are destined for identical pieces counting and can be used in store houses control of production and in similar tasks Counting pieces function 1s based on calculation individual mass of detail from sample weight or keyboard inscribed Scale avails a learn algorithm during calculation and this algorithm is correcting inaccuracy conversion Scale owns summing register This register allows to addition or subtraction of next result and observation current state of this register Scales grant claims of regulations abort safeties in European Union sign inform about that on brand table CE This type of scale not requires legalization PKW1U classification 33 20 31 2 Completeness Standard set consist of Scale 2 Carrying pan 3 Fish plate pan 4 Feeder 5 User manual 6 Guarantee card 4 OPERATION MANUAL 3 Security rules To avoid electrical shock or damage of the scale or connected peripheral devices it is necessary to follow the security rules below All repairs and necessary regulations can be made by authorised personnel only To avoid fire risk use a feeder of an appropriate t
2. PCS SPW AT tare subtract package weight from weighed mass approve options in menu zero option switch on switch off standby special key database print out special function menu change of mass units on main display change data on displays DATA temporary increased indication resolution gross weight indication switch get to record base start counting procedure with added sample long hold key turn on turn off function MIN OK MAX selection start counting procedure with subtractive sample long hold key turn on turn off function MIN OK MAX selection set a sample detail mass by numeric keys and ENTER added current indication to summing register subtracted current indication from summing register 8 OPERATION MANUAL Main display indicators result stabilisation indicator indicator a indicator Q zero indicator indicator NET net weight indicator indication with subtracted tare indicator kg g change of unit displayed indicators units of masses current indications lb oz ozt ct DATA display indicators indicator B G gross mass key B G indicator T actual tare indicator PT stored tare indicator APW sample mass indicator 2 contents of summing register COUNT display indicators indicator V not working indicator MIN indication under minimum threshold indicator OK indication between minimum and maximum threshold
3. Production Manager Jan Konczak Podpis 30 OPERATION MANUAL Notes
4. USER MANUAL BLM Series File 2011 10 04 BLM 136 010 GB 2 OPERATION MANUAL Index 1 General COSCON EE 3 NIE 3 Diy DCCV TOS 4 DTE 5 General VIEW ON DalaliGO saaan 6 6 Keys and indicators ne Preparation of work place nnne nnne nnn 9 D DIO WON CU a 9 NECI M 10 OAT OW Oli dE 11 POS 11 12 Summation of measurements series X sss 15 55 9 16 14 Connecting a computer OF a printer ccccccceeceetscesssenssensscesesessenssessesetsesserseseeeents 18 19 BASIC TUNCTON OESCHOUON kx MAGANA NAG A Rcx RAS ERA 20 NANG KNA 20 19 22 ach n acie ands kana 20 16 Special function description nnns 21 1 T X 22 16 2 Calibration with external weight CALID sese 23 16 3 Serial port parameters setting rS232 sene 24 16 4 Print out configuration function Print esee 25 16 5 Date and time setting function GALE
5. calculation on the basic of removed pieces default is 10 pieces second phase recalculating a weighting portion Put on pan a box with details 2 Turn a pieces counting by press 3PCS key and confirm by ENTER key 3 Remove one or more details from the portion 4 If one detail is removed press ENTER key If amount of removed is other write correct value by using numeric keys and ENTER 5 Number of details has been showed on right display with PCS indicator A sample mass has been showed in centered display with APW 6 Result of calculation 1s read from right display OPERATION MANUAL 13 Change write a sample mass by numeric keys During a pieces counting indicator PCS user can change actual sample mass Write a sample mass when a counting process is turn off initiate a counting process count MAXIS i in oPut kee b oz ot a kela ct Press a gt SPW key 2 Write sample mass by using a numeric keys and ENTER 3 Number of details has been showed on right display with PCS indicator A sample mass has been showed in centered display with AP W 4 Result of calculation is read from right display Note 1 It is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units 2 Err PCS communicate signalizes that a sample was not put on the pan or single piece weight is less than one reading uni
6. ON MANUAL 11 10 Start of work Leave the pan empty plug the feeder to the mains 230V S50Hz and plug the feeder connector to the 12V power socket at the bottom side of the scale Scale will execute following step test of electronic components display type of scale and version of program zeroing the indication After displayed an indication on the main left display scale is ready to work 11 Pieces counting PCS Scale enables to count identical pieces e g turnbuckles or buttons Measurement with single pieces putting on pan A measurement is performed in two phases first phase single piece weight calculation on the basis of defined pieces amount default 1s 10 pieces second phase pieces counting PLACE C p Put on pan quantified details sample 2 Turn a counting by press gt PCS key 3 If the quantified sample consists 10 pieces press ENTER solid line on the drawing If amount of detail 1s other write correct value by using numeric keys and ENTER dotted line on the drawing 4 Number of details has been showed on right display with PCS indicator A sample mass has been showed in centered display with APW indicator 5 Remove ample form pan and put o portion of pieces 6 Result of calculation 1s read from right display 12 OPERATION MANUAL Measurement with single pieces removing from pan A measurement is performed in two phases first phase single piece weight
7. erted values display together with a green diode in lower left corner of middle screen DATA count AXIS 10000 KAA nG 2 MA MIN OK x PCS e A o r pain amp mp C 4 After choosing the proper option user can insert numeral value using keyboard and confirm it with ENTER key Entering record library Shortly press LIB key to enter record library in order to readout inscribed earlier record User can differ saved records green diode lights on middle screen from empty ones count AXIS DATA re We choose record using 2 and 27 keys and confirm our choice by pressing ENTER It is also possible to inscribe directly the record number In order to do that press t and then insert numeral value using keyboard Confirm pressing ENTER key Selection of empty record is signalized by EMPtY message Currently used record is marked by additional n USE message If user wants to cancel choosing of records press CLR key 18 OPERATION MANUAL 14 Connecting a computer or a printer The scale is equipped with RS232C which can be used to connect external devices such as a computer or a printer When cooperating with a computer data is send after initiate signal from a computer or after a press L button RS232C Ry Receive TxD send When cooperating with the scale a computer should be equipped with a program which enables processing data Housin
8. ey choose Autot and Aut on To leave the function press MENU key then with ENTER key choose Autot and AUt OFF Note Autozeroing function 1s activated automatically for 10 min after switching on OPERATION MANUAL 23 16 2 Calibration with external weight CALIb Calibration with external weight standard in verified balances should be performed in case balance indications exceed permissible error To calibrate the balance a service centre should use calibration weight as stated in Technical Data table or of better accuracy Operations sequence Cause a user function by press MENU key Press ENTER key during the CALIb is displayed They will be displayed following options CAL OFF out without calibration CAL on calibration with external weight out leave option Press ENTER key during the CAL on 1s displayed Wait until zeroing 1s finished When LOAD communicate put a calibration weight on the pan Wait until calibration process 1s finished and zero indicated 24 OPERATION MANUAL 16 3 Serial port parameters setting rS232 v bh 15232 v v v v b The function enables to set the following transmission parameters standard parameters underlined bAud 4800 9600 115200 transmission speed bitS 7 amp the number bits in a byte PArlt 0 1 parity control Odd 0 1 type of parity Send continous transmi
9. g from the scale Mass The Axis company offers programs to cooperating with scales These programs are available on site www axis pl Test RS232C program to tests serial connections full version ProCell program enabling cooperation with Microsoft Excel or different Windows applications demo version Information for programmers transmission protocol describe Signal description Computer Scale initialising signal S I CR LF 53h 49h ODh OAh Scale Computer weighing result according to the diagram below 16Bytes transmission parameters bits Istop no parity 4800bps Byte description Byte 1 sign or space 2 space 324 digit or space 349 digit decimal dot or space 10 digit 11 space 12 k l c p or space 13 g b t cor 14 space 15 CR 16 LF OPERATION MANUAL 19 Connecting cable WK 1 connect scale with computer interface 9 pin SCALE ba COMPUTER Connecting cable WD 1 connect scale with printer KAFKA SCALE KAFKA PRINTER 20 OPERATION MANUAL 15 Basic function description 15 1 Normal weighing Press the 37 4 key when indication 1s different from zero at empty scale Weighing result should be read when the indicator lights The scale 1s equipped with tare equal to its range Joint value tare and netto mass can not surpass the range of weight Max OPERATION MANUAL 21 16 Special functi
10. l package Scale should be protected against pressure Error communicates C 1 6 self test failed if displayed more than 1 minute over min contact an authorised service balance protection rod remove protection rod and cap doesn t work the scale was switched on with remove the load from the pan loaded pan unstable ground place the balance on a stable ma vibrations ground not affected by indicator does air flows mechanical vibrations and airflows balance damage contact an authorized service EE taring 1s progress contact an authorized service not appear OPERATION MANUAL 29 Declaration of Conformity AXIS Sp lka z 0 0 80 125 Gdansk ul Kartuska 375B confirm with all responsibility that scales BLM 1 5 BLM5 BLM6 BLMI5 BLM30 marked with CE mark comply with the following 1 EN 55022 2000 standard Limits and methods of measurement of radio disturbance characteristics of information technology equipment and IEC 61000 4 3 Electromagnetic compatibility EMC Part 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test harmonised with the Council Directive 89 336 EEC Additional information Conformity evaluation for the Council Directive 73 23 EEC and 89 336 EEC were carried out by Laboratorium Badaweze Oddziatu Instytutu Elektrotechniki in Gdansk accredited by PCA Gdansk 23 03 2009 r Per pro Director of AXIS Sp z 0 0
11. m off date on the print bad t out on turn on date on the print out Pin access code 4 digits v GA dam 26 03 eves out leave the function ENTER v th CF mle cy IN OPERATION MANUAL 27 16 7 Customization function menu ACtIV i dEFAULt hh v Sy O ODE O bh ad WT This function enables to select special functions that will be displayed after pressing MENU key Easy access to the most useful functions will shorten operation time and make work more comfortable User can return to factory setting using special function dEFAULt Operation sequence shown on the picture presents how to add RS232C parameters setting function to the Function Menu To remove a function from the Function Menu choose rS oFF in the last operation 28 OPERATION MANUAL 17 Maintenance and repairs of small defects 1 The scale should be kept clean 2 Take care that no dirt gets between the platform and the scale base If found any remove the pan lift 1t up remove dirt and then replace the pan 3 In case of improper operation caused by short lasting power supply decay unplug the scale from the mains and then plug it again after few seconds 4 It is forbidden to make any repairs by unauthorised persons 5 To repair the scale please contact our nearest service List of authorized services 1s show on site www axis pl 6 Damages scales should be sent to repair only in origina
12. on description All scales beside basic functions like weighing and tare are equipped with the set of additional functions Basic set of user special functions consists of autozero Autot calibration with external standard weight CALIb serial port parameters setting 75232 print out configuration Print date and time setting dAZE menu customization function ACTIV return to default settings dEFAU Other special functions can be enabled as an option on customer request all functions are described in additional brochure when ordered Press MENU key to enter the function menu Functions are displayed successively with consecutive numbers F Autot F2 rS232 etc To customise the function menu with most frequently used functions use Menu Customisation function A CtIV To make clear how to manage with each function in further part of instruction descriptions are replaced with pictures Every time the picture of a hand appears press the indicated key put a load on the pan remove the load from the pan press the key when indication 1s mls displayed 3 3 forced change v VW automatic change 22 OPERATION MANUAL 16 1 Autozeroing Autot When F Aut function is activated the scale automatically ensures stable zero indication if the pan 15 empty or if zero indication was acquired by pressing T lt key To activate the function press MENU key then with ENTER k
13. ontinuous displaying of register in this case an indicator is turn on 16 OPERATION MANUAL 13 Data library LIB key The scale is equipped with data library where user can save detail characteristics number single piece mass default amount of samples and others in chosen record number and later when it is needed recall to it During scale work scanner configuration prefix 04h sufixx CR LF readout of detail number causes searching through scale record library and in case of finding the right record recalling single piece mass and other data Record library edition Longer pressing of LIB key enters edition menu On left display a Edit sign shows up and on the middle one a record identification number from 000 to 999 Next using 3 and Z keys choose record number and press Enter to edit it COUNT MAXIS Chosen record id will show up on the left display On the middle one following options will successively display PA no detail number inserting SPW single piece mass SPL default sample quantity PTARE inserting constant tare value for the detail undEr lower threshold value OVEr upper threshold value SAVE saving settings ErASE erasing settings out exit the library user can also use CLR key OPERATION MANUAL 17 To speed up options displaying user can press 2 and 27 button We choose option by pressing ENTER key options that have ins
14. s indicator MAX indication above maximum threshold indicator 2 signalize indication of summing register contents OPERATION MANUAL 9 7 Preparation of work place Works place of scale should be chosen carefully This place should be assured a proper temperature and essential area for attendance Weight should stand on stable table Violent movements of air dust vibrations violent changes of temperature or humidity above 90 are inadmissible Scale should be disallow from strong electromagnetically or magnetically fields 8 Preparation to work 1 Take the scale pan and 1 feeder out of the package N It is recommended to keep the original scale package in order to transport the balance safely in future 2 Place the scale on a stable ground not affected by mechanical vibrations and airflows 3 Put a carrying pan 2 in wholes 4 Put the fish plate pan 1 5 Level the scale with the rotating rear legs 6 so that the air bubble in the water level 3 at the back of the scale is in the middle If scale has been moved from places with low temperature to places with N upper temperature for example in winter please weight on time 4 hours purpose of acclimatization 10 OPERATION MANUAL 9 General rules 1 It is advised to check scale indication accuracy before and after series of measurement using any load with known weight To check the scale with legal verification uses a calibration weight wi
15. ssion without using LF key To set desired transmission parameters activate 7 232 function choose appropriate parameter and press ENTER key to accept needed parameter value The example at the left presents how to set transmission speed value to 9600bps To leave the function chooses out option OPERATION MANUAL 2 16 4 Print out configuration function Print v v v v ij b This function allows choosing following fields on the print out HEAd header name model and number of scale OPEr operator code max 6 digits dAtE date HME time Pr no number of print out choose his function 1s clearing a counter PA no product number 13 digits Count counting result totAL ammount of results APW netto mass tArE actuall tare value GrOSS gross mass If the function OPEr 1s checked operator code can be inscribe directlty by press t key The example at the left presents how to set header and operator code setting of other function 1s similar 26 OPERATION MANUAL 16 5 Date and time setting function dAtE option This function allows setting actual 0 009 MENU date time and setting a PIN code to protect by non authorized changes v This function is installed on the QATE ENTER special order v Press ENTER key during the dAtE GATE ENTER Is displayed They will be displayed following v M T ies tu
16. t it is possible to count pieces but measuring error is bigger 14 OPERATION MANUAL MIN OK MAX selection turn on turn off counting detail Hold a PCS PCS key causes display following options OFF disable a counting details on enable a counting details thr setting a threshold selection MIN OK MAX Pag COUNT MAXIS COUNT MAXIS COUNT OPERATION MANUAL 15 Set a value of threshold causes a turn on an indicators MIN OK 1 MAX state of these indicators depends on value on indicator and thresholds If the result of details calculation 1s lower than threshold undEr scale signalizes MIN between thresholds scale signalizes OK and during a pass a threshold scale turn on buzzer bigger than threshold OVEr and during a pass a threshold scale turn on buzzer Note On the first start scale value of thresholds are set to maximum During a setting a upper threshold remember that his value can t be lower that value of minimum threshold 12 Summation of measurements series Scale is equip In summation register That registers enable addition a next result of measurements count MAXIS 1 Put element on the pan and press Z button Contents of this register have been showed temporary in centered display with indicator Note Using a gt key causes a subtract indication from register 2 Press several times a DATA key to belongs for c
17. th valid calibration certificate In case permissible error is exceeded it 1s advised to contact the nearest service to calibrate the scale 2 Weighed sample should be placed in the centre of the pan 3 The scale 1s equipped with a tare equal to its range To tare the scale press T key left or right Storing a tare value does not extend measuring range but only subtracts it from a load placed on a pan To make weight control easier and to avoid range overdrawing the scale 1s equipped with a load indicator graduated in percentages 4 Weighing result should be read when the indicator lights which signalizes stabilization of a result 5 When the scale is not used but it is necessary to be ready to work immediately it can be switched off by pressing I O key The scale reading system 1s then switched off to standby mode To switch the scale on press I O key The scale is immediately ready to operate maximum accuracy after self tests 6 Before each measurement make sure that zero indicator 1s displayed If zero indicator does not displayed or communicate appears press 0 key and wait until zero indication and zero indicator appears 7 The mechanism of scale is a precision devices and susceptible on congestions impacts and mechanical shakes Do not overload the scale more then 20 of maximum load Max Do not press a pan by hand Scale should be protected during the transport Dp OPERATI
18. ype supplied with the scale Pay attention that supply voltage 1s compatible with specified technical data Do not use the scale when its cover 1s opened Do not use the scale in explosive conditions Do not use the scale 1n high humidity If the scale seems not to operate properly unplug it from the mains and do not use until checked by authorised service According to legal regulations it if forbidden to dispose wasted electronic equipment in waste containers Please return wasted scale to the point of purchase or other company specialised in recycling of wasted electronic components OPERATION MANUAL 5 4 Technical data Scale type BLM1 5 BLM3 BLM6 BLM15 BLM30 Maximum loading Max 1 5kg 15kg 30kg Reading unit d Minimal sample weight Pan dimension 250x180mm Working temperature 10 C 40 C Weighting time lt 3s Scale base dimension 255x310x107mm ocale weight 2 6k a AG Power supply 230V 50Hz 6VA 512V 1 2A 6 OPERATION MANUAL 5 General view of balance pan welt pan 2 carrying pan under welt 3 LED display 4 keyboard 5 level 6 rotary legs Connections views Feeder Supply 12V 500mA RS232C RxD Receive TxD send Mass OPERATION MANUAL 6 Keys and indicators count MAXIS 60000 OK Keys function description Te gt lt t LIB MENU UNITS DATA HR 5 G LIB PCS

Download Pdf Manuals

image

Related Search

Related Contents

InLine 76440R networking cable  IR4000DABWS Deutsche Bedienungsanleitung  EWS10 EWS11 Manual do usuário 1  Lucent Technologies 555-661  User`s Manual - Airis Support  Bedienungsanleitung/Garantie DONUT  

Copyright © All rights reserved.
Failed to retrieve file