1. H User s Manual ENGLISH CONTENTS INTRODUCTION 5 CAUTIONS 5 DESCRIPTION 7 IV INSTALLATION SWITCHING ON 9 4 1 UNPACKING THE DEVICE 9 4 2 RECOMMENDATIONS 9 4 3 INSTALLATION 9 4 4 FIRST USE 9 V USING THE DEVICE 10 5 1 USING THE HANDPIECE 10 5 2 USING THE 90 AND 120 NOZZLES 12 VI SERVICING PRE DISINFECTION CLEANING DECONTAMINATION AND STERILIZATION 12 6 1 RECOMMENDATION 12 6 2 SERVICING PRE DISINFECTION CLEANING AND STERILIZATION OF METAL 90 120 SUPRA NOZZLES AND HEAD 13 6 3 SERVICING AND CLEANING THE TANK 17 6 4 SERVICING PRE DISINFECTION CLEANING AND STERILIZATION OF THE HANDPIECE 20 VII CHECKING MAINTENANCE 23 7 1 CHECKING 7 2 MAINTAINING THE STOP POWDER PISTON 7 3 MAINTAINING THE METAL SHAFT 7 4 MAINTAINING AND REPLACING THE SILICONE RING 7 5 MAINTAINING AND REPLACING O RINGS 7 6 OPERATING FAULTS VIII DISPOSAL AND RECYCLING IX MANUFACTURER RESPONSIBILITY X REGULATIONS XI MANUFACTURER WARRANTY XIII DATE OF REVISION OF THESE INSTRUCTIONS XIV FIGURES 23 23 24 25 26 27 27 27 28 28 28 28 29 INTRODUCTION Congratulations on receiving your AIR N GO device Indications This medical device is used in conjunction with SATELEC dental polishing powder This medical device is intended for prophylactic treatments of dental and prosthetic surfaces Created by SATELEC AIR N GO is
2. Your device must be fitted with an adaptor compatible with your turbine connector Using a non compatible connector may permanently damage your device Autoclave cycles dry out the o rings It is necessary to lubricate all o rings after sterilization with grease silicone paste only Refer to Chap VII The turbine function of your unit shall not be activated during connection of your device The various connection accessories must be clean and completely dry Prior to each use check the condition of the o rings on your turbine connector 1 The presence of moisture may lead to clogging of the device powder air circulation pipes 4 3 INSTALLATION AW Important For supra gingival treatments only use the 120 or 90 nozzle that must be connected to the blue tank and AIR N GO CLASSIC or PEARL polishing powders Make sure there are no signs of moisture around the nozzle or in the powder tank Eliminate any moisture found by wiping and blowing with air using the multipurpose syringe Connect the device by simply plugging it into the turbine cord connector 4 4 FIRST USE Before using your AIR N GO device for the first time it is essential to service and to sterilize all equipment in accordance with the procedures defined in chapter VI Sterilization Only the nozzle Fig 1 1 or Fig 1 2 head Fig 1 3 or Fig 1 4 silicone ring Fig 1 5 plastic front body of the handpiece Fig 1 6 and metal sh
3. PEARL powder neutral e An AIR N GO PERIO kit transforming the AIR N GO into a sub gingival treatment device The maximum powder level is marked by a MAX line Figure 2 The STOP POWDER piston used to bleed and rinse the device with air and water is located on the tank lid Fig 1 10 The turbine adapter is equipped with check valves to prevent possible backflow of the dental chair unit 3 2 TECHNICAL CHARACTERISTICS a The device Name of device AIR N GO Manufacturer SATELEC Air supply by turbine cord 3 to 5 bars pressure recorded at the outlet of the turbine cord Water supply by turbine cord irrigation flow at 15ml min 5ml min Temperatures Operating 10 C to 40 C Storage 0 to 60 C Humidity Operating 30 to 5 Storage 10 to 75 condensation taken into account Principal performance specifications Air pressure flow Water pressure flow SATELEC abrasive dental powder controlled grain size Part s applied Polishing nozzle Front section of the medical device b Powders Refer to the AIR N GO powder instructions provided in the AIR N GO carrying case IV INSTALLATION SWITCHING ON 4 1 UNPACKING THE DEVICE Upon receipt of the device check for any damage that may have occurred during transportation and contact your supplier if necessary 4 2 RECOMMENDATIONS Connection to the dental unit The AIR N GO connection model must be identical to that of your turbine
4. 33708 MERIGNAC cedex France Tel 33 0 556 34 06 07 Fax 33 0 556 34 92 92 gt E mail satelec acteongroup com www acteongroup com www airngoconcept com
5. the non compliance with the instructions in this document 27 Note the manufacturer reserves the right to modify the device and or the user manual without notice X REGULATIONS This medical device is classified lla in accordance with the applicable European directive pertaining to Medical Devices This equipment was designed and manufactured in accordance with an ISO 13485 certified quality assurance system XI MANUFACTURER SATELEC 17 AVENUE GUSTAVE EIFFEL BP30216 33708 MERIGNAC CEDEX FRANCE Tel 33 0 556 34 06 07 Fax 33 0 556 34 92 92 E mail satelec actongroup com 0459 WWW acteongroup com Symbole Signification Washer disinfector for thermal disinfection 132 C Sterilization at 132 in an autoclave 134 C Sterilization at 134 C in an autoclave Refer to the user s manual Refer to the instruction manual For USA only Rx only United States Federal Law restricts the use of this device solely to qualified trained and competent dental professionals XII WARRANTY The warranty does not cover user misuse XIII DATE OF REVISION OF THESE INSTRUCTIONS This user manual was last revised in 05 2013 28 XIV FIGURES i 2 Q FIGURE 2 FIGURE 1 FIGURE 3 1 FIGURE 3 2 O Q 29 30 31 110200 V3 05 2013 SATELEC A Company of Acteon Group 17 av Gustave Eiffel gt BP 30216 gt
6. Fig 1 7 and the turbine adaptor Fig 1 11 Autoclave cycles dry out the o rings It is necessary to lubrificate all o rings after sterilization with grease silicone paste only Refer to Chap VII 134 C 132 C NERS Before starting the cleaning procedure it is essential to disassemble the tank and its lid see 6 3 Tank disassembly procedure Do not use an abrasive product to clean the device f the device has not been used or has been misplaced for a period of time you will need to empty the powder from the tank Disposal according to regulations in force and clean the powder tank Do not use the device if it appears to be faulty Prior to any sterilization check the cleanliness of your autoclave and the quality of the water used After each sterilization cycle immediately remove the parts from the autoclave to reduce risks of the corrosion of metal parts Sterilized parts must be left to cool and dry until they reach ambient temperature prior to being used again 6 2 SERVICING PRE DISINFECTION CLEANING AND STERILIZATION OF METAL 90 120 SUPRA NOZZLES AND HEAD Sterilization Only the nozzle Fig 1 1 or Fig 1 2 head Fig 1 3 or Fig 1 4 silicone ring Fig 1 5 plastic front body of the handpiece Fig 1 6 and metal shaft Fig 1 12 can be sterilized Do not sterilize the tank Fig 1 8 and its lid Fig 1 9 the plastic rear body Fig 1 7 and the turbine adaptor Fi
7. tank from the handpiece Bleed the device by pressing the control pedal on the dental chair for a minimum of 5 seconds Unscrew and remove the lid from the powder tank Empty all the powder from the tank Disposal according to regulations in force After each use it is important to service and to sterilize all equipments in accordance with the procedures defined in chapter VI 11 5 2 USING THE 90 AND 120 NOZZLES The patient and dentist must wear suitable protection accessories goggles masks Apply Vaseline to the patient s lips before polishing Point the nozzle at the tooth enamel ensuring a distance of 3 to 5mm Ensure a spray angle between the nozzle and the surface of the tooth of 30 to 60 degrees Do not spray directly on the gum Make small circular movements over the treated area Use a wide suction cannula and hold it near the area to be treated reduces bacterial air contamination The air powder spray continues for several seconds after releasing the control pedal Take this into account and wait before removing the nozzle from the patient s mouth to prevent irritation of the mucosa After polishing we recommend you apply a fluoride gel to the patient s teeth T Advise your patient not to smoke eat or drink anything that could stain the teeth for up to 2 to 3 hours following treatment VI SERVICING PRE DISINFECTION CLEANING DECONTAMINATION AND STERILIZATION Importa
8. REPLACING O RINGS It is important to check the integrity and presence of o rings on the nozzle metal shaft of the handpiece and the tank SATELEC recommends the carrying out of this inspection prior to each use Total number of o rings eight 8 on the metal shaft two 2 on the nozzle one 1 on the tank one 1 on the tank lid EV Ain E VET Check that the o rings are in good condition f necessary replace any damaged o rings with those supplied Spare o ring kit to order F10205 Return the metal shaft to its recess by pushing it Check that it is securely in place Note An o ring in poor condition may prevent correct operation of the device or damage it 26 7 6 OPERATING FAULTS Refer to the table below Check that the water inlet connection is correctly unattached or faulty connected No water Water flow adjusting ring If there is an adjusting ring on the turbine cord connector check that it is correctly adjusted Check that air is arriving at the dental chair air inlet Unscrew the nozzle from the handpiece body Check that air comes out of the handpiece by pressing the pedal No powder no air but If yes see paragraph 7 1 presence of water or weak If no go to the next step spray Nozzle clogged Unclip the tank Check once again that air is coming out of the Tank clogged and or handpiece tank side handpiece clogged If yes rem
9. a dental air polishing device used to perform treatments such as Supragingival prophylaxis treatments using a sodium bicarbonate or calcium carbonate based powder To maximise use of this cutting edge product for as long as possible please read this user s manual carefully before switching on using and servicing the device Sentences containing the symbol are points of particular importance Il CAUTIONS To reduce the risk of accidents please read and adhere to the following precautions User population This medical device can only be used by skilled and capable qualified dental health professionals as a part of their normal activities f you have received this device by mistake contact your supplier to arrange for its return The user must have a perfect practical knowledge of accepted dental rules and practices in compliance with established data of the science and of the principles of medical hygiene such as the cleaning disinfection and sterilisation of medical devices and must observe those rules practices and principles This medical device can be used irrespectively of specific adult user details such as weight age height gender and nationality The user must wear gloves The user is not the patient Users must not have any of the following ailments Eye problems unless the latter are appropriately corrected Disability of the upper limbs correct holding of a handpiece or of the lower lim
10. aft Fig 1 12 can be sterilized Do not sterilize the tank Fig 1 8 and its lid Fig 1 9 the plastic rear body Fig 1 7 and the turbine adaptor Fig 1 11 T Autoclave cycles dry out the o rings It is necessary to lubrificate all o rings after sterilization with grease silicone paste only Refer to Chap VII It is also vital to comply with the device user s instructions Refer to Chap V V USING THE DEVICE 5 1 USING THE HANDPIECE Important All accessories used must be previously pre disinfected cleaned and sterilized n order to bleed the device we strongly recommend you to connect the handpiece without the powder tank and hold the control pedal for a minimum of 5 seconds Repeat this action three times before assembling the tank Adjust the spray drop by drop Ts Sterilization Only the nozzle Fig 1 1 or Fig 1 2 head Fig 1 3 or Fig 1 4 silicone ring Fig 1 5 plastic front body of the handpiece Fig 1 6 and metal shaft Fig 1 12 can be sterilized Do not sterilize the tank Fig 1 8 and its lid Fig 1 9 the plastic rear body Fig 1 7 and the turbine adaptor Fig 1 11 Autoclave cycles dry out the o rings It is necessary to lubrificate all o rings after sterilization with grease silicone paste only Refer to Chap VII For your safety and that of your patient AIR N GO must only be used with the accessories supplied or recommended by SATELEC Thoroughly check the d
11. are pregnant or breastfeeding suffering from asthma chronic bronchitis or any other breathing disorders shall not be treated with this device As with all similar devices a sensitivity or allergy to the powder ingredients may become apparent during treatment In this case rinse the mouth with plenty of water to fully remove all traces of the powder To reduce the risk of powder inhalation and or of viral or bacterial air contamination the dentist and patient are advised to wear a protective mask and protective goggles Never point the device at the eyes even if it is not being used Accidental spraying of the powder into the eyes may cause ocular damage We strongly recommend that the dentist and the patient wear protective goggles during treatment We strongly recommend that patients remove corrective glasses or contact lenses prior to treatment Body areas or types of tissue treated The medical care can only be carried out in the patient s oral environment Principle of operation of the medical device Air and water are supplied to the medical device equipped with its dental powder tank The air penetrating into the tank creates a cloud of powder which is projected onto the clinical zone via a polishing nozzle The water air and powder are mixed together at the output of the medical device Use of the device Refer to IV and V Do not use the device if it appears to be damaged or faulty Do not connect or use your d
12. bs operation of a control pedal Ear problems use of audible signals depending on the equipment Memory or concentration problems settings sequences or medical procedures etc Specific training for users No specific training other than the original professional training is required in order to use this medical equipment Precautions of use The device is designed to be used with SATELEC CLASSIC or PEARL AIR N GO polishing powders The use of powders not supplied by SATELEC may compromise the effectiveness of the device and the safety of your patient Comply with the conditions of use for the powders recommended by SATELEC Refer to Powder instructions Patient population This medical device is intended for use on the following patient Population children teenagers adults and elderly people This medical device can be used irrespectively of specific patient details such as weight age height gender and nationality Interactions Contraindications The treatment of your patients with a dental device may cause bacteremia Prior to any treatment find out about the general health of your patients in particular in the case of patients e witha known allergy to one of the components of the polishing powder used suffering from endocarditis with an immune deficiency following a course of antibiotic chemotherapy radiotherapy treatment etc who are diabetic who are haemophiliac who
13. ction of the SUPRA nozzles and heads as follows Rinse soiled devices nozzle and head under running cold tap water for one minute Remove heavy soil using a soft bristled brush or clean soft lint free cloth Immerse the nozzle and head in a newly made enzymatic ultrasonic tank cleaner adhering to the concentration and contact time recommended by the solution manufacturer in terms of powder breakdown 15 Proceed for a minimum of 2 minutes Remove the nozzle and the head used from the ultrasonic tank and tap them on a hard surface to remove any remaining particles Rinse the SUPRA nozzle and head under running tap water for at least one minute Use a syringe or water jet to flush SUPRA nozzle head and hard to reach areas Manually clean all the devices for 2 minutes in a freshly prepared enzymatic cleaner solution adhering to the concentration and contact time recommended by the solution manufacturer Use a soft bristled brush to remove soil and debris Rinse devices thoroughly with deionized or purified water Repeat the cleaning procedure until no visible soil remains on devices Perform final rinse using deionized or purified water Automatic method after pre clean Use the following cycle parameters Time minutes Temperature Water Type of Detergent Cold tap water Hot tap water 40 C Enzymatic or Alkaline cleaner va Neutralize noe tap WALT odo IU Neutralizer if necessary
14. d at ambient temperature Before the next use in the event of a packaging non conformity repackage and resterilize in accordance with the defined protocol n the event of visible contaminations in the bag destroy the product g Product disposal Dispose of the nozzles and the heads in bins reserved for waste following treatment with risks of infection 6 3 SERVICING AND CLEANING THE TANK CAUTION Before using the device it is important to carefully check the integrity of the materials thread condition of the tank and its cap button STOP POWDER good maintenance of metal pins tank etc In case of damage observed replace immediately the entire tank tank and lid to stay in optimal conditions of safety during the pressurizing device a Tank disassembly procedure Firmly hold the AIR N GO handpiece in one hand Hold the tank Fig 1 8 with the other hand 17 Rotate the tank 1 8 of a turn counter clockwise to release it b Bayonet tank assembly procedure T Before fitting the tank the handpiece you must check that there is no powder on the o ring shown on the back of the metal shaft We strongly recommend checking the condition of the threads powder tank and lid Prior to each tank installation we strongly advise you to remove all traces of powder using the multipurpose syringe air spray or cleaning wipes Check that it is securely in place Cleaning and maintenance o
15. ded by the solution manufacturer Use a soft bristled brush to remove soil and debris Rinse devices thoroughly with deionized or purified water Use a syringe or water jet to flush the metal shaft air circulation Repeat the cleaning procedure until no visible soil remains on devices Perform final rinse using deionized or purified water 21 b Automatic pre disinfection cleaning of the metal shaft the silicone ring and the plastic front body Proceed to a pre disinfection and precleaning of the metal shaft Fig 1 12 the silicone ring Fig 1 5 and the plastic front body Fig 1 6 of the handpiece as per chapter 6 4 a Rinse soiled devices metal shaft and the plastic front body with its silicone ring under running cold tap water during one minute Remove gross soil using a soft bristled brush or clean soft lint free cloth Immerse these elements in a newly made enzymatic ultrasonic tank cleaner adhering to the concentration and contact time recommended by the solution manufacturer in terms of powder breakdown Proceed to a minimum of 2 minutes att Rinse the metal shaft the plastic front body with its silicone ring under running tap water for at least one minute Use a syringe or water jet to flush the metal shaft air circulation Manually clean all the devices for 2 minutes in a freshly prepared enzymatic cleaner solution adhering to the concentration and contact time recommended by the solutio
16. department WWW satelec com E mail satelec acteongroup com DESCRIPTION 3 1 PHYSICAL DESCRIPTION Refer to XIV The AIR N GO handpiece is comprised of e An adjustable 120 SUPRA standard polishing nozzle Fig 1 1 e A long metal head Fig 1 3 e A handpiece body which is comprised of A non slip silicone ring Fig 1 5 A plastic front body Fig 1 6 A rear body Fig 1 7 A metal shaft Fig 1 12 A turbine adapter Fig 1 11 depending on the quick coupling model of the turbine refer to listing of compatible turbine couplings the WWW airngoconcept com AN We encourage you to use exclusively the turbine coupling of the original manufacturer e A blue SUPRA CLIP N GO powder tank with a bayonet system Fig 1 8 e A SUPRA powder tank lid Fig 1 9 OO O0 O 0 The basic AIR N GO box contains in addition to the items mentioned above A short metal hygienist head Fig 1 4 A SUPRA nozzle cleaning probe Fig 3 1 An AIR N GO handpiece body cleaning probe Fig 3 2 A set of replacement o rings 5 single dose sticks samples of 4 flavors 1 PEARL A 2509 bottle of CLASSIC peppermint powder Optional e An adjustable 90 SUPRA polishing nozzle Fig 1 2 e Set of 4 x 250g multi dose bottles with pouring spout or box of 50 x 20g single dose disposable sticks o AIR N GO CLASSIC powders natural aromas available depending on option peppermint lemon raspberry cola or neutral 0 AIR N GO
17. erse the SUPRA nozzle and the metal head in a newly made alkaline ultrasonic tank cleaner adhering to the concentration and contact time recommended by the solution manufacturer in terms of powder breakdown Proceed for a minimum of 10 minutes Remove the nozzle and the head used from the ultrasonic tank and tap them on a hard surface to remove any remaining particles Rinse the SUPRA nozzle and head under running tap water for at least one minute Use a syringe or water jet to flush SUPRA nozzle head and hard to reach areas Manually rinse all the devices for 6 minutes in a freshly prepared alkaline cleaner solution adhering to the concentration and contact time recommended by the solution manufacturer Use a soft bristled brush to remove soil and debris Rinse devices thoroughly with deionized or purified water Use a syringe or water jet to flush SUPRA nozzle head and hard to reach areas Repeat the manual cleaning procedure until no visible soil remains on devices Perform final rinse using deionized or purified water b Drying Using the multipurpose syringe air spray and or a clean disposable non woven cloth dry until there is no liquid left Proceed to sterilization as per chapter 6 2 e C Automatic pre disinfection and cleaning i Precleaning Proceed to a pre cleaning of the SUPRA nozzles and head as per chapter 6 2 a i ii Automatic pre disinfection and cleaning Proceed to the pre disinfe
18. evice and its accessories before and after each use to identify any problem If necessary do not use the device and replace any faulty parts Use your AIR N GO device as follows In order to bleed the device and remove any water into the air circulation pipe or on the quick coupling system Connect the handpiece to the turbine cord connector Rotate the tank 1 8 of a turn counter clockwise to release it Remove the tank from the handpiece gt Press the control pedal on the dental chair for minimum of 5 seconds Adjust the water flow 15ml min x 5ml min Repeat this operation three times between every reassembly of the tank 10 t is essential to repeat this action each time you must connect and disconnect the handpiece on its cord connector Unscrew and remove the lid from the powder tank Fill the tank with the powder recommended by SATELEC making sure you do not fill above the MAX line Reinstall the tank on the handpiece Rotate the tank a 1 8 of a turn clockwise to secure it by locking the bayonet system d QU X Check that the tank is securely in place Treat your patient as required by pressing the control pedal on the dental chair At the end of the treatment or prior to sterilization simultaneously press the STOP POWDER piston on the tank lid Fig 1 10 and the control pedal on the dental chair to bleed and rinse the device A Remove the
19. evice if the o rings on your turbine connector are worn Never open or fill the powder tank when the device is in use Do not fill the powder tank over the MAX line Fig 2 Use a completely dry powder Make sure that the powder tank is completely dry Do not put water in the powder tank Do not use the device without irrigation Do not use the device for any purpose other than that for which it was designed Prior to treatment do not shake the device Moving powder may clog the device pipe For best results from first use in the mouth test first on an oxidised metal object e g coin Do not point the device at the patient s eyes Environment Do not cover the device during use Do not use outside Do not place the device near a heat source Make sure that the cord connecting the device to the unit does not prevent people from moving around unobstructed When not in use store the device in its original packaging in a suitable place where it will not endanger people Servicing Refer to Before and after each use it is essential to thoroughly pre disinfect and clean your device using products recommended by SATELEC Prior to each intervention it is essential to use pre disinfected cleaned and sterilized accessories f the device has not been used or has been misplaced for a period of time fully empty and clean the tank to remove all powder residues Refer to Chap VI T Sterilization Only the n
20. f the bayonet tank We recommend that you clean the tank after each use 18 Fully and systematically empty all powder from the tank if the device is not going to be used for several hours e g overnight Residual air humidity alters the properties of the powder i Inside of the tank and the lid Remove all traces of powder residue from inside the tank and the lid using the multipurpose syringe air spray Clean the tank central outlet orifice using the probe diam 1mm Fig 3 2 Fully eliminate all traces of powder residue by using the multipurpose syringe air spray again and placing your index finger over the tank outlet 3 a Use a dry cloth to clean the inside of the tank and its lid The presence of humidity may cause blockage of the device powder or air circulation pipe 19 ii Outside of the tank and the lid The outside of the tank and its lid must be cleaned daily with a dry cloth 6 4 SERVICING PRE DISINFECTION CLEANING AND STERILIZATION OF THE HANDPIECE ta 1 aS 134 C 132 C 134 C 132 C a Servicing and manual cleaning of the AIR N GO handpiece i Cleaning of the AIR N GO handpiece After each use you must clean the handpiece in order to remove the residual powder The entire AIR N GO handpiece must be cleaned daily using cleaning wipes Disconnect the AIR N GO handpiece from the turbine cord prior to pre di
21. g 1 11 13 T Autoclave cycles dry out the o rings It is necessary to lubrificate all o rings after sterilization with grease silicone paste only Refer to Chap VII V 134 C 132 C Important During sterilization metal parts of a different nature must not be in contact with each other Any contact will lead to the creation of galvanic couples resulting in local deterioration To prevent this phenomenon place the objects individually in a sterilisable microporous bag or cloth Pre disinfection and manual cleaning i Precleaning of the SUPRA nozzles and head This operation must be performed with gloves immediately following the treatment After each use unscrew the nozzle Fig 1 1 or Fig 1 2 from the body of the AIR N GO handpiece Remove any possible residual powder from the 90 or 120 nozzle using the SUPRA nozzle cleaning probe diam 0 5mm Fig 3 1 provided in the case Repeat this action twice Only use the cleaning probe diam 0 5mm Fig 3 1 supplied in your AIR N GO case Remove any residue from inside the nozzle using the air spray of the chair multipurpose syringe 14 Unscrew the head Fig 1 3 or Fig 1 4 from the AIR N GO handpiece body ii Manual pre disinfection and cleaning Rinse soiled devices nozzle and head under running cold tap water for one minute Remove heavily soiled devices using a soft bristled brush or clean soft lint free cloth Imm
22. lization duration 4 minutes Pressure 1 85 bars minimum VII CHECKING MAINTENANCE Important In the event of a fault we recommend that you contact the supplier of your device rather than a general repair center who could render your device dangerous for you and your patients 7 1 CHECKING You will need to check the device and its accessories regularly to detect any fault or deterioration Where necessary replace faulty parts The tank and its lid are wearing parts repetitive uses abrasion screwing unscrewing maintenance cleaning as such it is recommended to replace the entire tank tank and lid preventively each 12 to 18 months T CAUTION you must comply with this advice notably to prevent any risk of clogging by the powder inside the AIR N GO handpiece 7 2 MAINTAINING THE STOP POWDER PISTON FIG 1 10 Make sure that the STOP POWDER piston on the tank lid is working correctly by pressing and releasing it several times 23 In case of malfunction immerse the lid into the ultrasonic cleaner This can also be done as a preventive measure Check that there is an o ring in the lid Check the status of wear of the o ring and replace it if necessary Spare o ring kit to order F10205 7 3 MAINTAINING THE METAL SHAFT Recommendation To ensure the device works for as long as expected we recommend that you clean the outside of the metal shaft and check the condition of the o rings a
23. n manufacturer Use a soft bristled brush to remove soil and debris Rinse the devices thoroughly with deionized or purified water Use a syringe or water jet to flush the metal shaft air circulation Repeat the cleaning procedure until no visible soil remains on devices Perform final rinse using deionized or purified water Automatic method after pre clean Use the following cycle parameters Time minutes Temperature Water Type of Detergent Cold tap water Hot tap water gt 40 C Neutralizer if necessary Rinse 2 E Distilled or purified water water gt 40 C Dy Thermal Disinfection For automated cleaning thermal disinfect at 90 C for a minimum of 5 minutes d Sterilization of the plastic front body and the metal shaft After each treatment store the metal shaft Fig 1 12 the silicone ring Fig 1 5 and the plastic front body Fig 1 6 of the handpiece separately in disposable sterilization sleeves or bags in 22 compliance with the specifications defined in standard EN ISO 11607 or in any equivalent standard that may be required by national regulations The sterilization conditions and cycles are Autoclave Type B in compliance with standard EN 13060 Sterilization temperature 134 C Sterilization duration 3 to 18 minutes Pressure at least 2 bars minimum Autoclave Type B in compliance with standard EN 13060 Sterilization temperature 132 C Steri
24. neutralizer if necessary 2 Rinse with distilled or purified Distilled or purified water water gt 40 C d Thermal disinfection For automated cleaning thermal disinfect at 90 for a minimum of 5 minutes e Sterilization of nozzle and head l CAUTION Prior to sterilization remove any liquid from the accessories To ensure sterile and aseptic conditions keep all parts in hermitically sealed tanks or bags designed for medical use After each treatment store the disassembled nozzle and head separately in disposable sterilization sleeves or bags in compliance with the specifications defined in standard ISO 11607 or in any equivalent standard that may be required by national regulations 16 Sterilize the nozzles and the heads separately in an autoclave in compliance with the following parameters bees pe 1 d gt Autoclave Type B in compliance with standard EN 13060 Sterilization temperature 134 C Sterilization duration 3 to 18 minutes Pressure at least 2 bars minimum Autoclave Type B in compliance with standard EN 13060 Sterilization temperature 132 C Sterilization duration 4 minutes Pressure 1 85 bars minimum Autoclave cycles dry out the o rings It is necessary to lubrificate all o rings after sterilization with grease silicone paste only Refer to Chap VII f Storage Next store the sterilized products in a dry place free from dust an
25. nt The servicing pre disinfection cleaning and sterilization instructions that follow must be applied after each use of the device or its accessories Utilisation Depending on the number of utilisations of the medical device and or on the number of cleaning disinfection and sterilisation cycles performed on the sterilisable parts the performance of the medical device may decline 6 1 RECOMMENDATION a At the end of the working day you must Simultaneously press the STOP POWDER piston on the tank lid Fig 1 10 and the control pedal on the dental chair to transform the devise into an air and water syringe Before disconnecting the handpiece from the turbine connector remove the powder tank and bleed the device by pressing the control pedal on the dental chair for a minimum of 5 seconds Disconnect the handpiece from the turbine connector Empty all the powder from the tank Disposal according to regulations in force and clean the tank with compressed air Unscrew and clean the nozzle b After each use of the device and its accessories The device must be disconnected during pre disinfection and cleaning procedures 12 T Sterilization Only the nozzle Fig 1 1 or Fig 1 2 head Fig 1 3 or Fig 1 4 silicone ring Fig 1 5 plastic front body of the handpiece Fig 1 6 and metal shaft Fig 1 12 can be sterilized Do not sterilize the tank Fig 1 8 and its lid Fig 1 9 the plastic rear body
26. ove the lid from the tank and refer to paragraph 7 2 inside the tank If not contact your nearest SATELEC dealer Fill the tank up to the MAX line or empty out any powder that is over the MAX line Only use powders recommended by SATELEC Drop in device performance Empty and clean the tank and fill with completely dry powder STOP POWDER piston Immerse the lid of the tank into the ultrasonic blocked or still activated bath Irregular spray but water Check the presence and integrity of the o rings at present the tank the metal body and the nozzle Leakage of water from the 5 5 If necessary replace them with spares provided in handpiece tank or nozzle the case VIII DISPOSAL AND RECYCLING When your device or its accessories have reached the end of their service life we recommend that you contact your nearest dental equipment dealer or visit the ACTEON GROUP site whose list is included in chapter XI to find out how to proceed Tank empty or too full MANUFACTURER RESPONSIBILITY The manufacturer shall not be held responsible in the event of non compliance with manufacturer recommendations during installation intervention modifications or repairs carried out by people who have not been authorised by the manufacturer usage other than that specified in this manual the use of accessories and or powders that have not been recommended by SATELEC
27. ozzle Fig 1 1 or Fig 1 2 head Fig 1 3 or Fig 1 4 silicone ring Fig 1 5 plastic front body of the handpiece Fig 1 6 and metal shaft Fig 1 12 can be sterilized Do not sterilize the tank Fig 1 8 and its lid Fig 1 9 the plastic rear body Fig 1 7 and the turbine adaptor Fig 1 11 Autoclave cycles dry out the o rings It is necessary to lubrificate all o rings after sterilization with grease silicone paste only Refer to Chap VII 134 C 132 C ys Accessories The device was designed and developed with its accessories in order to provide optimum safety and performance The device can only be fitted with devices designed by SATELEC of a suitably adapted purpose The use of accessories or powders supplied by other manufacturers or not recommended by SATELEC may present a risk for you your patients or your device The infringement of these cautions fully implicates the dentist in the event of a problem Repair Do not repair or modify the device without the prior authorization of SATELEC If the device is modified or repaired specific inspections and tests must be performed to ensure that the device can still be used safely n the event of a fault we recommend that you contact the supplier of your device rather than a general repair center who could render your device dangerous for you and your patients If in doubt contact an approved dealer or the SATELEC customer service
28. sinfection cleaning and sterilization of the silicone ring Fig 1 5 and the plastic front body Fig 1 6 of the handpiece After each use remove the tank unscrew the nozzle and the head from the body of the AIR N GO handpiece Remove all residual powder from the ducts of the handpiece metal shaft using the cleaning probe diam 1 mm Fig 3 2 supplied with the device 20 Only use the handpiece body cleaning probe diam 1mm Fig 3 2 supplied in your AIR N GO case Remove any residue from the AIR N GO handpiece metal shaft using the multipurpose syringe air spray Rinse soiled devices metal shaft and plastic front body with its silicone ring under running cold tap water for one minute Remove heavy soil using a soft bristled brush or clean soft lint free cloth ii Manual pre disinfection and cleanin Immerse the elements in a newly made alkaline ultrasonic tank cleaner adhering to the concentration and contact time recommended by the solution manufacturer in terms of powder breakdown Proceed for a minimum of ten minutes Remove the plastic front body with its silicone ring and the metal shaft and rinse them under running tap water for at least one minute Use a syringe or water jet to flush the metal shaft air circulation Manually clean all the devices for 6 minutes in a freshly prepared alkaline cleaner solution adhering to the concentration and contact time recommen
29. t least once to twice per month Autoclave cycles dry out the o rings It is necessary to lubrificate all o rings after sterilization with grease silicone paste only Refer to Chap VII a Metal shaft and nozzle disassembly procedure Disassemble the nozzle and the head and remove the plastic front body Hold the rear body in one hand Take hold of the metal shaft with your other hand Pull the metal shaft to remove it from its recess b Maintaining the nozzle and metal shaft Clean the outside of the nozzle and metal shaft once or twice per month using cleaning wipes Check wear of the o rings Replace them if necessary Refer to 8 4 24 Spare o ring kit to order F10205 We advise you to lubricate the o rings on the nozzle and the metal shaft with silicone grease only Replace then when necessary We strongly recommend removing the excess of silicone grease with a dry cloth C Metal shaft assembly procedure Relocate the metal shaft in its recess by pushing it Check that it is securely in place In case of clogging of the metal shaft or nozzles refer to the troubleshooting table or the maintenance flyer 7 4 MAINTAINING AND REPLACING THE SILICONE RING In the same way as for the handpiece the outside of the silicone ring must be cleaned with cleaning wipes We recommend replacement of the silicone ring annually or when it appears faulty 25 7 5 MAINTAINING AND