Home
User`s Manual EN
Contents
1. 11 SAFETY PRECAUTIONS J Do not install the device in a place subject to direct sun light without protective cover Do not install the device and cabling close to a source of strong electro magnetic fields like radio transmitting antenna Do not place the device near or above heating equipments If cleaning do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel Do notlet children touch the device without supervision Note that if the sensor is cleaned by detergent benzene or thinner the surface will be damaged and the fingerprint can t be entered 12 TROUBLESHOOTING J There were 15 unsuccessful attempts of authentication The Red Led on the Biometric Reader is blinking all the time Finger or PIN The Red LED will turn off after the first accepted finger or PIN Check the Ser No of the Readers Check if proper termination is done as described before Check if the Communication wires A amp B are properly connected to the reader Enrollment from desktop reader can be done but the Fingerprints are not sent to all Biometric Readers in the network The Biometric Reader is not powered ON The tricolour LED is OFF Check the power Supply red amp black wire If the user is not deleted from the reader and the same user is enrolled again with new ID the reader will recognize the finger with the first ID To resolve this delete
2. Valid from 1 28 2014 Mana Waliser Mateja Svet Valid unti 12 31 2099 l ll Controller2 Michaela Figgini i i i e Michaela Tabb Apply Anb pass policy v Setimage i F i H 5 H Main Entrance Nikola Cuculov Unset image Paul Hunter g Single entry User Stole Toda Barda Save changes Delete user Properties Check version Firmware update Get settings Send configuration 34 Delete all users from reader Z Upload all users to reader tq Delete pending updates BE Delete expired users from reader Header Door Event 8 3 ENROLLING FINGERPRINTS FROM DESKTOP READER Plug the Desktop Reader BIOE in the PC If the device is not installed automatically use the drivers located on the CD provided with the Biometric reader It is installed in the same way as a USB Device When the desktop reader has been installed it will automatically appear in the Software 8 13 1 Openthe Users Window and create a new user Click on New User put a name and ID card number 8 7 2 Go to the Biometric Tab 3 Select the USB desktop Reader with left click 4 Place the finger on the BIOE right click on the fingertip and select enroll 8 9 5 The finger tip will turn red with the percentage of successful enrollment shown next to the fingertip 8 10 6 Repeat point 5 for each finger that should be enrolled 7 Click on Save New and the fingerprint will be sent automatically to all Biometric Read
3. po p ow Yellow zm pi WEGAND py vaso Gray Tamper Glue m Tamper 5 CONNECTING BIOMETRIC READERS TO EWS CONTROLLER J The Biometric readers can be connected to virtually any controller that conforms to Wiegand format standards standard Wiegand 26bit or self defined Wiegand The lines DO and D1 are the Wiegand lines and the Wiegand Number is sent through them The RS485 line A B is used for fingerprint transfer and reader settings The Biometric readers must be powered from the controller f you use different power supply for the biometric reader connect the GND from the both devices to ensure correct transfer of the wiegand signal When you have connected the reader and powered on the LED should flash in orange light 2 beeps This lets you know it s on and ready for use Fingerprint enrollment is done from the PC Software Connection between the Biometric readers and the PC must be established C40 LD22 S at EL 12Vdc Out IN LN MARIAM 2 5Om max BUSES MILD Ser No 11 04 16 013 e Mac 00 04 A3 16 90 D T ZNI VVV ZNI LNNNNGNOA zsa pub eee ous eel IEEE AES aN9 ORT QQ 3N AZL Si Im0ACL Ben CQ ONS q e BFN v ssr Su e ANIL pe1 aosa OAI z pe1 ears ANIL pet eas AJY z p27 e214 PY DO ondi2v DT im pink A violet B green LG orange LR black GND red 12V white DO yellow D1 5 1 CONNE
4. B OC3 Biometric Reader User s Manual Contents DEE THE 3 2 SPECIFICATIONS es 3 3 MOUNTING EEEE 3 4 WIRING s cccssssssetnvtvvssssssesenasasenmuisivvviisssssisnnsesuunmisvivessssssssassssuisiuvsvsssssesaseeeeee 2 5 CONNECTING BIOMETRIC READERS TO EWS CONTROLLER es i 5 1 CONNECTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS a 5 5 2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP IP COMMUNICATION ss 5 6 CONNECTING BIOMETRIC READERS TO 3RD PARTY CONTROLLER L 011 6 6 1 CONVERTERS PIN DESCRIPTION ssssssssssssssR A e e e ee ee e ee ee ee es eh es s a ye ya ye ye ae a e ea e een 6 BS PR UA gt 8 CONFIGURING THE BIOMETRIC READERS IN PROS SOFTWARE 1 11e 7 8 1 ADDING BIOMETRIC READER cnet y e e e s ee eee een 7 8 2 ENROLLING FINGERPRINTS FROM A READER sss sss she he bbb a spen n g 8 3 ENROLLING FINGERPRINTS FROM DESKTIOPRREADER aaaea aaaea EEEE s e e em e en EEEE eei 9 So DEE VIG ENEE ENEE AE ut ede cbse etd rb EE 10 8 5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS ehe dn eee nra we d oie XU raga n tein Re ve x en phase ged 10 shobdlishugicR Di c 11 8 7 SENSOR CALIBRATION n 8 7 SEND CONFIGURATION seen 11 8 9 ADVANCED SETTING 11 9 CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER CONFIGURING THE BIOMETRIC READERS IN BIOM
5. L weg K K EK Ki S D o s Ec WI Kb WI Kb WU 2 n 2 2 uc i d y 110418013 E H o 11 06 1613 gt H oe Pi E 11 04 16 013 10443 15 90 D MA 15 90 D Mac 00 04 43 15 90 D m e u s nm E e When all the controllers are connected via TCP IP then the RS485 network becomes local from Reader 1 to the Controller then to the Reader 2 e Connect the readers directly to the Rs485 terminals in each controller e f the distance Reader Controller is high bOmeters and if the communication with the reader can not be established then terminate the RS485 network by closing the jumper in the EWS Controller or as described in chapter 4 6 CONNECTING BIOMETRIC READERS TO THIRD PARTY CONTROLLERS 3rd party controller 3rd party controller D0D1 _ DO0D1 D0D1 DOD1 BIOE USB Desktop Reader RS485 A A A RS485 B B tt optional BIOMANAGER Software La CSS DAG MAMM cp o E fale SSS e Connectthe lines DO D1 Gnd and 12V to the third party controller e Connect the RS485 Line A B to the converter Connect the converter in the PC e Fingerprint enrollment is done from the PC Software Connection between the Biometric readers and the PC must be established e The Biometric readers communicate with each other with a RS485 and with the PC Software through a Converter e The RS485 Line should be configured in the form of a daisy chai
6. Type BIOC3 8 6 Controllers Readers Search Basic Free Access Time Zones Biometric 5 Entrance SN l Serial 05 08 12 055 ww Serial Type Version BIOPAD M 2 1206 1500 BIOC3 n7 Sound level 5 Finger Acceptance Flexibility Automatic Secure Sensitivity 0 lowest 7 X C Send this ID for unknown finger 0000000000 EF Properties BIOINFROX 49 Firmware update BIOINPROX gt BIOINPROXSW ml a BIOPAD M Add Controller CU Send configuration BIOPROX EM d dit i A Calibrate BIOPROX MF a Properties BIOPROX MF FOC j a KI BIOXRC DW Delete Portal Delete all users from reader BIOXRSW Bm e Lat 2 Upload all users to reader DINBIO i d Search devices DINBIO DINMTPX M Ze DINBIO DINMTPX MF Firmware Update E cde pied cen from seals Get settings Memory status Delete pending updates 8 2 ENROLLING FINGERPRINTS FROM A READER 1 Open the Users Window and create a new user Click on New User put a name and ID card number 8 7 Go to the Biometric Tab Select the reader with left click from which the enrollment will be done 8 8 Right click on the fingertip and select enroll 8 9 In the next 25 sec present the finger on the selected reader and the finger tip will turn red with the percentage of successful enrollment shown next to the fingertip 8 10 In these 25 sec the reader will continuously blink in orange Repeat point
7. USB Biometric reader Note The Desktop Biometric reader BIOE is only compatible to Biometric readers with capacitive sensor not with the ones with thermal sensor Fingerprint Transfer Finger templates can be sent to any Reader in the Network Different Users can be sent to different Biometric readers PIN Codes management and transfer PIN Code length configuration 1 to 8 digits and PIN Code transfer Wiegand Output Configuration The Wiegand output of the Biometric reader can be customized bitwise 9 1 ADD READER Fill the Reader form Right click on the portal connected to the reader and select Add reader T Add reader m DUOUOUOUOU UDUUOOUUDU DUDUDUOUOD aam OO CCCII Click on Save and the reader icon appears Right click on reader and select Version info under the selected portal WD a m M i ara e S a 7 Network portal R Version info If reader is online new line is added on top of the event table If reader is online right click on reader and select Upload configuration 10M d gra as quant d Main entry Upload configuration 2 3 2010 15 55 15 Network portal Main entm Configure parameters SUCCES 9 2 EDIT READER Right click on the reader and select Properties Edit reader properties and click Save button Right click on the reader and select Upload configuration Te pee Properties Upload configuration Check at event table if configuration was s
8. device ON or OFF Finger Acceptance Flexibility Accepted tolerance The recommended value is Automatic Secure Sensitivity Bio sensor sensitivity the recommended value is 7 most sensitive roller3 Aj Send configuration Calibrate 5 11 000 Memory status Delete all users from reader X e D Z Upload all users to reader Ca Z Delete pending updates Delete expired users from reader Device Main Entrance BIOC2 Firmware file Version Product GU Upload Properties S Check version Firmware update Er Get settings ay send configuration Calibrate Memory status Delete all users from reader Upload all users to reader Delete pending updates Delete expired users from reader S Properties ge Check version Firmware update Er Get settings Calibrate Memory status Delete all users from reader Upload all users to reader Delete pending updates Delete expired users from reader Basic Free Access Time Zones Biometric Serial 14 08 16 001 Sound level 0 Finger Acceptance Flexibility Automatic Secure Sensitivity 0 lowest 7 v Send this ID for unknown finger 777 Backlight 50 9 CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER BioManager is software for fingerprint management of XPR Biometric readers when used with third party access controllers Main functions Fingerprint Enrollment It can be done by ANY Biometric reader in the network or by Desktop
9. the parameters and do not change it later For more information please refer to BioManager User Manual 10 WIEGAND PROTOCOL DESCRIPTION The data is sent over the lines DATA O for the logic 0 and DATA 1 for the logic 1 Both lines use inverted logic meaning that a pulse low on DATA O indicates a 0 and a pulse low on DATA 1 indicates a 1 When the lines are high no data is being sent Only 1 ofthe 2 lines DATA O DATA 1 can pulse at the same time Example data 0010 DO 5V OV 1 ms E 100 us D1 5V OV Data bit O approximately 100 us microseconds Data bit 1 approximately 100 us microseconds Time between two data bits approximately 1 ms millisecond Both data lines DO and D1 are high Description for the 26 bits Wiegand format Each data block consists of a first parity bit P1 a fixed 8 bits header 16 bits of user code and a 2nd parity bit P2 Such a data block is shown bellow Parity bit bit1 8bitsheader 16bitsusercode 2 bytes Parity bit bit 26 P1 XXXXXXXX XXXXYYYY YYYYYYYY P2 Example 170 21527 1 10101010 0111101100100111 0 Note Parity bits are calculated as follows P1 even parity calculated overthe bits 2 to 13 X P2 odd parity calculated over the bits 14 to 25 Y E AAA AAA AAB BB BB BBBBBBBBBBHBI3oO MN PT Parit Parit Sr Site Code User Code pe
10. w e f 1st july 2006 Selon les Directives Europ ennes 2002 95 EC et 2002 96 EC ce produit est en conformit avec la norme ROHS pour la restriction des substances dangereuses Directive 2002 95 EC et ce produit ne doit pas tre depose avec les ordures municipales mais doit tre remis aux organismes gouvernementaux ou municipaux indiqu s et designes a cet effet pour permettre leur recuperation et leur r utilisation selon la directive WEEE Directive 2002 96 CE w e f 1st july 2006 In conformit alle direttive europee 2002 95 CE e 2002 96 CE Questo prodotto in conformit con la restrizione d utilizzo delle sostenze pericolose ROHS Direttiva 2002 95 CE e questo prodotto non deve essere gettato nella raccolta rifiuti indifferenziata ma deve essere portato alle apposite raccolte rifiuti realizzate dal governo o dalle autorit municipali per permettere il recupero e il riciclo dei materiali come da normativa WEEE Direttiva 2002 96 CE w e f 1 july 2006 A partir de las Directivas Europeas 2002 95 EC y 2002 96 EC Este producto cumple con la restricci n de sustancias peligrosas bajo ROHS Directiva 2002 95 EC y este producto no puede eliminarse en la red minicipal de basuras y debe manipularse seg n las instrucciones del gobierno o autoridades locales para permitir su recuperaci n y reciclado a partir de WEEE Directiva 2002 96 EC w e f 1 de julio de 2006 Gem EU Richtlinie 2002 95 EC amp 2002 96 EC Diese
11. 4 amp 5 for each finger that should be enrolled 7 Click on Save New and the fingerprint will be sent automatically to all Biometric Readers where that user has access i e to all the readers according to the Access Level assign to that user U AUN lon Example If the user has Unlimited Access level then the fingerprints will be sent to all readers if the user has Access level only for Reader1 and Reader 3 then the fingerprints will be sent only to those two readers Note To check if all the fingerprints are sent to the reader right click on the reader and select Memory Status 8 11 In the event window a line will appear indicating the number of fingerprints stored in the reader 8 12 Note If more fingerprints are added for one user all fingerprints will send the same Wiegand Code to the controller the one written in the field User ID card Number Output control 13 Biometry User ID s Card numbers 5339048 Access Code 1234 Sitecode 81 Usercode 30632 Select reader to Enroll Wiegand26 ID 5339048 Sitecode 81 Usercode 30632 Send or Delete user Ari Peka Nicola Sele ct fed Nar Ann Staplewood S Dee mith qaa B ad 192 168 1 100 Dino Radja e Basic 4 Personal details d Personal details 2 E Output control T Biometry i Domnika Barda D Elena Access level Unlimited l B H D2 140626004 Hans Enn Department General Y B R2 140626004 John Smith Workgroup None Josh Lee
12. ANAGER EE 12 9 1 ADD READER se 12 SAC PINE READER EEN 13 A WI READER EN 14 9 4 CALIBRATE SENSOR A ID ee 14 IIT ee 14 9 7 DELETE USERS eene 15 9 8 ENROLL FINGERS CDI 15 9 9 UPLOAD FINGERPRINTS TO READER essen 15 9 10 DELETE FINGERPRINTS 16 9 10 1 Deleting one user from the biometric reader sss eee nnne eene 16 9 10 2 Deleting all users fromthe biometric reader ee 16 9 11 COMPLEX USER UPLOAD 2222 2L ees ee n ls 16 9 12 CUSTOM WIEGAND 2222 11 LJee e Re eneepes ees s enl erp enden een een rn n 17 10 WIEGAND PROTOCOL DESCRIPTION Ghee Reed Ri EIHPODERE NEGO HI OE UD OEC IRIHE EREM AER I Sob o 18 11 SAFETY PRECAUTIONS rrm m 19 1 DESCRIPTION BIOC3 is a Wiegand biometric reader for indoors access control applications It offers storage up to 9500 fingerprints and programmable Wiegand Output 8to 128 bits Configuration of the readers and fingerprint enrollmentis done through PC Software Connection between the biometric readers is RS485 and it is used for fingerprint transfer and configuration When used with third party controllers the connection between the Biometric readers and the PC is done through a converter CNV100 RS485 to RS232 or CNV200 RS485 to USB or CNV300 RS485 to TCP IP Only one converter is needed per sy
13. CTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS Jumper for RS485 termination 1M O TCP IP 1 km max 32 Units EWS Biometric Readers Hooooooooooooo s 50 ohm e The Biometric readers are connected through RS485 bus The same RS485 bus that the EWS controllers are connected to e Maximum units in one network EWS Biometric readers is 32 e Ifthere are more than 32 units in one network please utilize RS 485 HUB to connect e The RS485 Line should be configured in the form of a daisy chain NOT in a form of a star If star must be used in some points keep the stubs from the RS485 backbone as short as possible Maximum length of the stub is dependant of the installation total number of devices in RS485 line total cable length termination cable type so recommendation is to keep stubs shorter than 5 meters keeping in mind that this can be possible reason for errors in Communication with PC software e The cable must be twisted and shielded with a min 0 2 mm2 cross section e Connect the ground OV of each unit in the RS 485 Line using a third wire inthe same cable e The shield of the communication cable between two devices must be connected to the EARTH from ONE side of the RS 485 Line Use the side that has earth connection to the building s grounding network 5 2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP IP COMMUNICATION TCP IP Ser No Ser No
14. all users from the reader and upload all users to the reader Check the Wiegand Bus yellow amp white wire Check if the ground of the controller and the Biometric Reader is the same Check if the length between Biometric Reader and the controller is less than 50 m Fingerprint or PIN Code is recognized the tricolor LED is green but the controller reports other ID number and the access is denied Electro static discharge influences the Fingerprint Connect the housing of the Biometric Reader to the scan earth wire Check if fingerprint reading area is dirty Do not clean the device with any form of liquid Use soft and dry cloth Reader reading performance is decreased only Reading area is damaged If the damage is minor try to calibrate the sensor Retry after drying the wetness of your finger When your finger is too dry touch your forehead and try Fingerprint is not recognized normally again When you have a cut on your registered finger register another fingerprint As per the European Directives 2002 95 EC amp 2002 96 EC This product is in compliance to the restriction of hazardous substance ROHS under Directive 2002 95 EC and this product should not be disposed in the municipal waste stream but should be handed over to any designated collection facilities appointed by the government or the local authorities to enable recovery amp recycling as per WEEE Directive 2002 96 EC
15. ard numbers 5339048 Access Code 0000 Properties Name Site code 81 User rode 30632 o pee Wiegand26 ID 5339048 Sitecode 81 Usercode 30632 Ari Peka Nicola David Smith t Dino Radja Basic Personal details Personal details 2 E Output control Biometry Fi rmware u pd ate Domnika Barda J D A Get sett E ings Check version Elena na UU Hans Enn Department General M Send configuration John Smith None e Calibrate Workgroup Valid fron 28 20 E ana aliser Mateja Svet Valid until 12 31 2099 Memory status Michaela Figgini Michaela Tabb Nikola Cuculov Joi z m oe Paul Hunter ibiq 4 amp Upload all users to reader G9 Delete pending updates Apply Ant pass policy v Setimage Single entry User Stole Toda Barda S Delete expired users from reader ei Delete all 8 5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS Right click on the biometric reader E SE Properties Select Upload all users to reader Door2 Check version While receiving the fingerprints the reader will blink in orange mere Get settings I7 11 0t D Send configuration 3 Calibrate Note Use this feature when you change or add a reader if pending tasks are deleted in the software or if there are doubts that fingerprints in the reader Memory status memory are not synchronized with the software database Delete all users from reader I
16. ck the users to be deleted e Right click on the users table e Click on Delete checked users menu Confirm warning message e Select the User in the User Column not the check box the check box is for sending the fingerprints and the User name cell will turn blue e Select the Biometric reader or Desktop reader BIOE from where the enrollment will be done J BioDesk Blim s a ea E x je TEE uu nen click on the fingertip and ek je wm NON ea Select Enrol Swipe the finger on the Reader and the finger tip will become blue with percentage of successful enrollment given right beside the fingertip Note If more fingerprints are added for one user all fingerprints will send the same Wiegand Code to the controller 9 9 UPLOAD FINGERPRINTS TO READER Check the users which fingerprints will be sent to the Reader Right click on the Biometric reader those users should be sent and select Upload users As each user is being sent the checkbox will become unchecked indicating that the user is successfully sent In the same time the orange LED of the Biometric reader blinks Note Average time fortransferring one finger template is 0 6 sec Note The PIN Codes are also being sent if there are any Upload users 9 10 DELETE FINGERPRINTS After the transfer the fingerprint are stored in the Biometric reader and in the PC Deleting can be done only in the software only in the readers or from the both p
17. ers where that user has access i e to all the readers according to the Access Level assign to that user If the reader is off line the fingers will be sent upon the connection is established between PROS server and the reader No need for additional enrollment or actions The fingerprints will be sent as soon as communication is established Example If the user has Unlimited Access level then the fingerprints will be sent to all readers if the user has Access level only for Reader1 and Reader 3 then the fingerprints will be sent only to those two readers Note To check if all the fingerprints are sent to the reader right click on the reader and select Memory Status 8 11 Inthe event window a line will appear indicating the number of fingerprints stored in the reader 8 12 Note If more fingerprints are added for one user all fingerprints will send the same Wiegand Code to the controller the one written in the field User ID card Number Find user Name Ste code 81 User code 30632 Wiegand26 ID 5339048 Sitecode 81 Usercode 30632 Select reader to Enroll AR PUN OM le ct reag Send or Delete user David Smith Dino Radja eo Basic v Personal details P Personal details 2 E Output control T Biometry N a f es lnc Domnika Barda Ann Staplewood gag MyP Elena NENNEN Tore er r Hans Enn Department Genera x B w 192 168 1 100 John Smith Workgroup None Josh Lee i B a test ne
18. laces 9 10 1 Deleting one user from the biometric reader Select the users checkbox The user is deleted from the reader but his fingerprints are still in the software s database They can be sent ones again without the need of re enrollment 9 10 2 Deleting all users from the biometric reader Right click on the Reader and select Delete all Delete all 9 11 COMPLEX USER UPLOAD Complex user upload is used to sent multiply user selection to more readers Click on Upload table at main menu mory Status Upload table t English Use mouse click to select the combination you need or use right click to check or clear entire row or column Ae NN T RN NT T E Tom Smith a Select Upload Users to readers or Delete Users from readers at right click menu As upload is progressing check boxes are cleared mining appropriate combination was successfully done When upload is over if there are still checked items repeat the upload command 9 12 CUSTOM WIEGAND BioManager has defined Wiegand 26 and 34 bit as standard options and other 3 Wiegand settings as user definable To setup custom Wiegand format Select Wiegand menu from Settings Custom 3 At Wiegand setup window select one from customs Wiegand Wiegand eee Click on Save button v o Wb Jo p p W a w p po po po po p j o pe m he ha D M5 Je Note Wiegand settings are out of scope for common end user Please ask your installer to set
19. n NOT in a form of a star Keep the stubs from the RS485 backbone as shortas possible not more than 5 meters e Only one converter per installation is needed not per reader 6 1 CONVERTERS PIN DESCRIPTION PIN 1 PIN 1 PIN 1 CNV100 CNV200 CNV300 Converter RS485 to RS232 Converter RS485 to USB Converter RS485 to TCP IP Does not requires installation Requires installation as USB serial Does not require installation IP device refer to CNV200 Manual The address set through Internet Drivers are located on the CD Browser refer to CNV300 Manual Biometric Reader Converter RS 485A PIN 1 RS 485 RS 485 B PIN 2 RS 485 7 ENROLLMENT J 8 CONFIGURING THE BIOMETRIC READERS IN PROS CS SOFTWARE 8 1 ADDING BIOMETRIC READER 1 Expand the Door item to view the readers 2 Right click on the reader and select properties 8 1 3 In the Basic tab for Type of the Reader select BIOC3 8 2 4 After selecting the type a third tab will appear Biometric Go to that tab and put the serial number of the Biometric Reader 8 3 Important Note The serial number of the reader can be found on a sticker inside the reader on the packaging box and it can be search from the software right click on the portal search devices readers 8 4 amp 8 5 To check if the reader is On Line right click on the reader and select Check version In the Event Window a message should appear Device ON Line
20. n normal usage the fingerprints are sent automatically and this feature is 2 Delete pending updates not used SC Delete expired users from reader 8 17 8 6 FIRMWARE UPDATE E Main AF Properties Joor2 Check version Right click on the reader and select Firmware update menu 8 18 sm Jutputs e Get settings On the Firmware update window click on the Browse button 8 19 The default location of the firmware files installed with PROS CS is in the folder roller4 Firmware Select the firmware file with a xhc extension Click on the Upload button Important Wait for the update end message Do not turn off the reader the software or any communication device in between during the entire process 8 7 SENSOR CALIBRATION Right click on the biometric reader and select Calibrate and wait for confirmation message Note It is recommended to do a calibration while commissioning the reader and in cases when there are problems with reading the fingers 8 8 SEND CONFIGURATION Right click on the reader and select the Send configuration menu See the events panel to check the configuration flow Note The biometric reader gets its settings automatically This function is used if the reader was off line while making the changes 8 9 ADVANCED SETTINGS Send This ID for Unknown Finger sends the desired Wiegand when an unknown finger is applied Click on the Save amp Exit button Sound level Sound level of the
21. s Produkt erf llt die Vorschriften zur Beschr nkung gef hrlicher Substanzen gem RoHS Richtlinie 2002 95 EC Es darf nicht mit dem Hausm ll entsorgt werden sondern ist zwecks Aufbereitung und Verwertung gem WEEE Richtlinie 2002 96 EC bei einer daf r beh rdlich eingerichteten Sammelstelle abzugeben w e f 1 Juli 2006 Volgens de Europese Richtlijnen 2002 95 EC amp 2002 96 EC Dit product is overeenkomstig met het risicobeperkingswezen volgens de richtlijnen 2002 95 EC en dit product mag niet verloren gaan in de gemeentelijke afvalstroom maar zal moeten worden overhandigd aan een aangestelde inzamelvoorziening aangewezen door regering of gemeente voor herstel en recycling volgens WEEE Richtlijn 2002 96 EC W E F 1 juli 2006 Visual Plus Corporation s a Dr ve Richelle 161 e WOP G Bte 34 e XDI 1410 Waterloo Belgium Plus Company
22. stem one converter for 1 2 3 30 31 Biometric readers The tamper switch output can trigger the alarm system if an attemptis made to open or remove the unit from the wall 2 SPECIFICATIONS J Fingerprint capacity up to 9500 fingerprints Technology Biometry Authentication Finger Fingerprints per user 1 10 fingerprints Interface Wiegand 8 to 128 bits Default Wiegand 26bit Protocol programming By PROS software EWS system and BIOMANAGER all access control systems Cable distance 50m Fingerprint Sensor Type Capacitive 1 1000 identification time 970 msec including feature extraction time Fingerprint enrolment On the reader or from the USB desktop reader BIOE Panel Connection Cable 1m Green and Red LED Externally Controlled Orange LED Idle mode Buzzer Yes Backlight ON OFF Yes by software settings Tamper Yes Consumption 100mA IP Rating 54 Power supply 9 14V DC Operating Temperature 0 C to 40 C Dimensions mm 92x51x25 Housing Moulded Aluminium Colour Silver Red Green Dark Grey Blue White 3 MOUNTING J AT HP IU E ft eege o 2893 HI SE EELQ2LO pem 25mm 92mm 4 WIRING Red mam 12V DC Black wm GND ae s Pink A A ees Violet m B TTT ev muss Orange mum LED Red Green pm LED Green White
23. uccessful LO UM h EE been D Oral Ze Em 23 2010 17 58 16 Network portal Main entry Configure Wiegand SUCCES 2 3 2010 17 53 15 Network portal Main entm Configure Flexibility Level SUCCES 28 03 2010 17 58 15 Network portal Mam entry Save Flexibility Level SUCCES dar U32010 15 59 15 Network portal Main entm Configure parameters SUCCES 9 3 DELETE READER Right click on the reader and select Delete reader Delere reader 9 4 CALIBRATE SENSOR Right click on the reader and select Calibrate See the events panel to check the calibration flow It is recommended to do sensor calibration once after reader is mounted Clean the fingerprint sensor before calibration 9 5 ADD USER At user table click on the last empty user field and enter user name 1 NN NN Click on ID User code field and enter ID number This number will be sent by the reader to the access controller when user finger is recognized by the reader Click on PIN code field and enter the PIN PIN code is used at readers with keypad When PIN code is typed at reader User ID will be sent to the access controller 9 6 EDIT USER e Find the user at user table to edit Click on the user field for edit Name ID or PIN Type new value Press Enter on the keyboard Important When ID is changed warning message is displayed reminding that if ID exist in some reader should be deleted from reader prior to change 9 7 DELETE USERS e Che
24. w 39 Valid from Mana Walser Mateja Svet Valid until 12 31 2099 ij amp D acim x J BT da E reen Nikola Cuculov l i Yy 192 168 1 201 j i Controller2 e Main Entrance L B Main Entrance E d D Door2 T b Toda Barda A Properties S Check version Firmware update Get settings pntroller3 4 Send configuration pntroller4 gt Calibrate 99 11 00 34 Delete all users from reader d Upload all users to reader G Delete pending updates BE Delete expired users from reader Reader Door Event 8 4 DELETING FINGERPRINTS In General the fingerprints are stored in the Biometric reader and in the Software Deleting can be done only in the readers or from both places Deleting one user from the biometric reader Select the User Click on Delete User The User together with its fingerprints will be deleted from both the software and the fingerprint readers 8 14 Deleting all users from the biometric reader Right click on the reader and select Delete all users from reader 8 15 Delete one or more fingerprints Select the User and open the Biometric tab Go to the fingertip that needs to be deleted right click and select Delete for one finger or Delete All for all fingers of the User Click Save Changes With this procedure the User s fingerprints are deleted from the software and from the reader 8 16 Find user Username Enca Hess UserlD s C