PEL 102 PEL 103 - Chauvin Arnoux Group
Contents
1. OU gt END TEO S GO a lt ODA Suc THE S N SEE NUK E GATI AN DES lt gt PRODUCT PACKAGING Shipping Contents MODEL PEL 102 MODEL PEL 103 POWER amp ENEF 1 Small Classic Tool Bag Cat 2133 72 POWER amp ENERGY LOGGER o zel EO EA X 30 KE 1 of the following 12 ID Markers Power amp Energy Logger Model PEL 102 Cat 2140 45 Power amp Energy Logger Model PEL 103 Cat 2137 51 2137 52 2137 61 2137 62 3 MiniFlex MA193 10 BK Cat 2140 48 1 USB SD Card Adapter included only with Cat 5000 45 the purchase of Cat 2137 51 or Cat 2137 52 4 Black Test Leads and Alligator Clips Cat 2137 76 1 Power Cord Also Included 1 Multifix mounting system Cat 5000 14 1 Safety Sheet for the PEL Cat 5000 44 1 Safety Sheet for the MiniFlex Sensors 1 Compliance Sheet 1 2 GB SD Card 1 Quick Start User Guide 1 5 ft USB Cable 1 4 GB USB Stick with User Manual amp DataView Software Cat 2140 46 1 Battery NIMH AAA 8 4V Cat 2137 75 USB STICK DataView software and user manuals for the Power Energy Logger PEL and Current Probes can be found on the USB stick supplied with the instrument Control Features MODEL PEL 103 POWER amp ENERGY LOGGER ON OFF START STOP seo fY o sz ED E PEL 108 CONTROL BUTTON Starts stops the recording session a
2. oe j FRA IVA PEL 103 POWER amp ENER ON OFF y START stop S D a START Stop he aa led AEMG INSTRUMENTS Q ONC AS U f AV JE J OXO certifies that this instrument has been calibrated using JE standards and instruments traceable to international e standards NO g Chauvin Arnoux Inc d b a AEMC Instruments We guarantee that at the time of shipping your instrument has met its published specifications CU OD S D An NIST traceable certificate may be requested at the time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge W DED is Sa The recommended calibration interval for this instrument is 12 months and begins on the date of 0 receipt by the customer For recalibration please use our calibration services Refer to our repair and calibration section at www aemc com OSSEC FT ES A WY OY Serial KO Catalog 2137 51 2137 52 2137 61 2137 62 Model PEL 102 PEL 103 CSS CCD Y Ce UD Please fillin the appropriate date as indicated KX OE Date Received CEDO CoE E uD Date Calibration Due Chauvin Arnoux Inc DB d b a AEMC Instruments z INSTRUMENTS www aemc com 2 ue Sa cama A es E G gt D E lt J f l ESSES SS ES Ss sa a Statement of Compliance 7 A O ONO ae D EO CCO
3. V2 V3 NAM 12 13 3 Phase 3 Wire A Balanced 1 current sensor e Connect the terminal V1 test lead to L1 e Connect the terminal V2 test lead to L2 e Connect the terminal l3 current probe to L3 A g0 4a nr v V2 V3 NAM 3 Phase 4 Wire Y Balanced e Connect the terminal N test lead to Neutral e Connect the terminal V1 test lead to L1 e Connect the terminal l1 current probe to L1 iz QA Tv V2 V3 NAM 12 l3 NOTE Ensure that the current arrow on the sensor is directed towards the load This ensures proper phase angle for power measurements and other phase sensitive measurements 3 Phase 3 Wire Y 3 current sensors Connect the terminal V1 test lead to L1 Connect the terminal V2 test lead to L2 Connect the terminal V3 test lead to L3 Connect the terminal l1 current probe to LI Connect the terminal l2 current probe to L2 Connect the terminal l3 current probe to L3 4 OQ rR v V2 V3 NAM 12 13 3 Phase 4 Wire Y 3 current sensors Connect the terminal N test lead to Neutral Connect the terminal V1 test lead to L1 Connect the terminal V2 test lead to L2 Connect the terminal V3 test lead to L3 Connect the terminal l1 current probe to LI Connect the terminal l2 current probe to L2 Connect the terminal I3 current probe to L3 L2 Q gt Q Bi v V2 V3 NAM I2 13 3 Phase 4
4. Wire Y 212 Element Connect the terminal N test lead to Neutral Connect the terminal V1 test lead to L1 Connect the terminal V3 test lead to L3 Connect the terminal l1 current probe to LI Connect the terminal l2 current probe to L2 Connect the terminal I3 current probe to L3 L2 lt Q O Px v V2 V3 NAM 12 NOTE Ensure that the current arrow on the sensor is directed towards the load This ensures proper phase angle for power measurements and other phase sensitive measurements 3 Phase 4 Wire A 3 Phase 4 Wire Open A Connect the terminal N test lead to Neutral Connect the terminal N test lead to Neutral Connect the terminal V1 test lead to L1 Connect the terminal V1 test lead to L1 Connect the terminal V2 test lead to L2 Connect the terminal V2 test lead to L2 Connect the terminal V3 test lead to L3 Connect the terminal V3 test lead to L3 Connect the terminal l1 current probe to LI Connect the terminal l1 current probe to LI Connect the terminal l2 current probe to L2 Connect the terminal 12 current probe to La Connect the terminal I3 current probe to L3 Connect the terminal 13 current probe to L3 4 em fi Em N FR rR v V2 V3 NAM 12 13 v V2 V3 NAM 12 l3 DC 2 Wire DC 3 Wire e Connect the terminal N lead to the common conductor Connect the terminal N lead to the common conductor e Connect the terminal V1 test lead to cond
5. the selected hook up diagram Do not forget to define the transformer ratio when necessary Mounting The PEL is equipped with integrated magnets on the back panel used for mounting to a magnetic surface or it can also mount to a door top using the Multifix multi purpose mounting accessory Setting a Recording Start Stop To start a recording perform one of the following e In the PEL Control Panel Select the option from the Recording tab of the Configuration dialog box The instrument can be configured to start a recording either at a future date time or immediately upon writing the configuration to the instrument e On the Instrument Press and hold the CONTROL button until the Green LED lights then release the control button This starts the instrument recording using the previous configuration settings To stop a recording perform one of the following e Inthe PEL Control Panel From the menu select Instrument gt Stop Recording e On the Instrument Press and hold the CONTROL button until the Green LED lights then release the control button Viewing the Recording Recorded data can be transferred to the PC for viewing and report generation in one of two ways e The SD card can be removed from the instrument and connected to the PC via the supplied SD card reader Start the PEL Control Panel select the Open command from the File menu point to the icp file with the desired session number on the SD card and se
6. le to N I S T Includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 E mail repair aemc com Or contact your authorized distributor Costs for repair standard calibration and calibration traceable to N I S T are available NOTE You must obtain a CSA before returning any instrument Technical and Sales Assistance If you are experiencing any technical problems or require any assistance with the proper operation or application of your instrument please call mail fax or e mail our technical support team Chauvin Arnoux Inc d b a AEMC Instruments 200 Foxborough Boulevard Foxborough MA 02035 USA Phone 800 343 1391 508 698 2115 Fax 508 698 2118 E mail techsupport aemc com www aemc com NOTE Do not ship Instruments to our Foxborough MA address IE AEMC INSTRUMENTS 10 13 99 MAN 100372 v3 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive e Dover NH 03820 USA e Phone 603 749 6434 e Fax 603 742 2346 www aemc com
7. lect Open e Direct connection between the PC and the PEL USB Network or Bluetooth Start the PEL Control Panel open a connection to the instrument select the instrument be sure the instrument is connected in the tree view and select Recorded Sessions Double click on the desired recording session When downloading is complete select the downloaded test and click the Open button in the Download dialog box In both cases the session is added to My Open Sessions in the PEL Network Data can now be viewed DISTRIBUTION SYSTEMS AND PEL HOOK UPS NOTE Ensure that the current arrow on the sensor is directed towards the load This ensures proper phase angle for power measurements and other phase sensitive measurements Single Phase 2 Wire e Connect the terminal N test lead to Neutral e Connect the terminal V1 test lead to L1 e Connect the current probe to L1 Source Q Load v V2 V3 NAM 12 i 3 Phase 3 Wire A 2 current sensors e Connect the terminal V1 test lead to L1 e Connect the terminal V2 test lead to L2 e Connect the terminal V3 test lead to L3 e Connect the terminal l1 current probe to LI e Connect the terminal 13 current probe to L3 2 esa v V2 V3 NAM 12 13 3 Phase 3 Wire Open A 2 current sensors e Connect the terminal V1 test lead to L1 e Connect the terminal V2 test lead to L2 e Connect the terminal V3 test lead to L3 e Connect the terminal l1 current p
8. nd enables disables Bluetooth The function is obtained by a 2s press on the CONTROL button which causes the lighting of the REC LED for 3s followed by the Bluetooth LED in sequence REC LED START STOP release while lit starts recording if stopped release while lit stops recording if started BLUETOOTH LED ON OFF A release while lit enables Bluetooth if disabled release while lit disables Bluetooth if enabled PEL 102 Same features as the PEL 103 without the LCD Enter or Navigation buttons MODEL PEL 102 POWER amp ENERGY LOGGER ENTER BUTTON PEL 103 Only Displays partial energies long push NAVIGATION BUTTON PEL 103 Only Enables browsing and the selection of displayed data ON OFF BUTTON To turn ON Connect the power cord into an AC outlet To turn OFF Disconnect the power cord from the AC outlet then press the ON OFF button for gt 2s NOTE The instrument cannot be turned OFF while connected to an AC outlet or if a recording is in progress TOP VIEW Lead Inputs Voltage Inputs Current Inputs Location for Color coded ID Markers see page 7 for input connection diagram BOTTOM VIEW Connections Ethernet Connection RJ 45 Power Cord SD Card USB Connection Slot LED Status LED GJE under ON OFF button embedded in the connector embedded in the connector STATUS Green LED Rec
9. ording Status LED blinks once per second every 5s Logger in standby not recording LED blinks twice per second every 5s Logger in recording mode Blue LED Bluetooth LED OFF Bluetooth OFF disabled LED ON Bluetooth ON enabled not transmitting LED blinks twice per second Bluetooth ON enabled transmitting Red LED Phase Order OFF Phase rotation order correct LED blinks once per second Phase rotation order incorrect Red LED Overload OFF No input overload LED blinks once per second At least one input is in overload LED ON Indicates a current probe is either mismatched or missing Red Green LED SD Card Status Green LED ON SD Card is OK Red LED blinks five times every 5s SD Card is full Red LED blinks four times every 5s less than 1 week capacity remaining Red LED blinks three times every 5s less than 2 weeks capacity remaining Red LED blinks twice every 5s less than 3 weeks capacity remaining Red LED blinks once every 5s less than 4 weeks capacity remaining Red LED ON SD Card is not present or locked Yellow Red LED Battery Status When the AC power cord is connected the battery charges until it is full LED OFF Battery full with or without power supply Yellow LED ON Battery is charging Yellow LED blinks once per second Battery is recovering from a full discharge Red LED blinks twice per second Low battery and no power supply Green LED ON OFF LED ON External power supply
10. pening the PEL Control Panel in DataView e Connect the power cord to an AC outlet The File Edit View Instrument Tools instrument will power on ETT e Connect the supplied USB cable to the PEL m ES and the PC Wait for the drivers to finish i i fa Workstati installing before proceeding Er Workstation 1 8 PEL Network Er PEL 102 12345 ee 3 Recorded Sessions e Double click the PEL icon LI located on your desktop to open the PEL Control Panel HU KB Real time Data EI E Foxborough Par 5 Recorded Sessions AD Real time Data E E PEL1O3_004_RUN3 9 Recorded Sessions e Select the Add an Instrument icon from the toolbar or the main Instrument menu e Follow the instructions from the Add an Instrument wizard If the Control Panel cannot locate the instrument in the drop down list click on the Refresh button or disconnect and reconnect the USB cable J kn Real time Data d My Open Sessions ES Main distibution box E bey 1 min Summary e When a connection to the instrument has been established the instrument s name should appear along the left side of the Con trol Panel within the PEL Network len 1s Measurernents Sim 1s Harmonics u Ej Session Totals Example of the PEL Network within the Control Panel Configuring the Instrument To configure the PEL select the instrument in the PEL Network branch Open the Configure Instrument dialog box from the Configure icon on
11. present LED OFF No external power supply Green LED Ethernet LED OFF No activity LED blinking Activity Yellow LED Ethernet LED OFF The stack failed to initialize or Ethernet controller failed to initialize Blink Slow toggle every second The stack initialized properly Blink Fast toggle 10 times per second The Ethernet controller initialized properly Blink Twice toggle 2 times then pause DHCP Error LED ON Network initialized and ready for use Installing DataView O DO NOT CONNECT THE INSTRUMENT TO THE PC BEFORE INSTALLING THE SOFTWARE AND DRIVERS 1 Insert the USB stick into an available USB port wait for driver to be installed If Autorun is enabled an AutoPlay window should appear If Autorun is disabled it will be necessary to open Windows Explorer then locate and open the USB stick drive labeled DataView to view the files on the drive 3 Inthe AutoPlay window select Open folder to view files 4 Double click on Setup exe from the opened folder view to launch the Dataview setup program NOTE For more information on using the DataView software refer to the Power Energy Logger PEL user manual that is supplied on the USB stick SD Card Insert the supplied SD Card into the PEL SD Cards up to 2 GB and SDHC Cards 4 GB up to 32 GB are supported e 2GB card supports a 4 week recording if harmonics are not recorded e Hot extraction is possible when not recording O
12. robe to LI e Connect the terminal I3 current probe to L3 3 eso L2 L1 v V2 V3 NAM 12 13 Single Phase 3 Wire Connect the terminal N test lead to Neutral Connect the terminal V1 test lead to L1 Connect the terminal V2 test lead to L2 Connect the terminal l1 current probe to LI Connect the terminal l2 current probe to L2 Dal 8 N Fr IA v V2 V3 NAN 12 13 3 Phase 3 Wire A 3 current sensors Connect the terminal V1 test lead to L1 Connect the terminal V2 test lead to L2 Connect the terminal V3 test lead to L3 Connect the terminal l1 current probe to LI Connect the terminal l2 current probe to L2 Connect the terminal l3 current probe to L3 A o o FR Vi V2 V NAN R B 3 Phase 3 Wire Open A 3 current sensors Connect the terminal V1 test lead to L1 Connect the terminal V2 test lead to L2 Connect the terminal V3 test lead to L3 Connect the terminal l1 current probe to LI Connect the terminal l2 current probe to L2 Connect the terminal 13 current probe to L3 L3 4 Gun L2 L1 PN a VI V2 V3 NAH I2 3 Phase 3 Wire Y 2 current sensors Connect the terminal V1 test lead to L1 Connect the terminal V2 test lead to L2 Connect the terminal V3 test lead to L3 Connect the terminal l1 current probe to LI Connect the terminal I3 current probe to L3 L2 Q Q v
13. the toolbar the Instru ment menu or the Status frame This dialog box consists of five tabs Configure Instrument General Communication Measurement Recording Meters e General Provides instrument labeling fields auto power off control LCD control operation button control set clock and format SD card options e Communication Options for Bluetooth and LAN connections e Measurement Distribution system selection voltage ratio frequency selection and setting for current sensors e Recording Options for selecting recording parameters e Meters Resets meters and options for partial energy reset periods Click on the x button to transfer the new configuration to the instrument Installation of the Leads and Current Sensors Twelve sets of color coded rings and inserts are supplied with your PEL instrument Use these ID markers to identify the leads and input terminals e Detach the appropriate inserts from the color coded marker and place them in the holes provided under the terminals larger inserts for current terminals smaller inserts for voltage terminals e Clip the rings of the same color to the ends of the lead you will be connecting to the terminal Connect the measuring leads to your PEL as follows e Current measurement l1 12 13 4 pin connectors e Voltage measurement V1 V2 V3 and N terminals The measuring leads must be connected to the circuit to be monitored according to
14. uctor 1 Connect the terminal V1 test lead to conductor 1 e Connect the terminal l1 current probe to conductor 1 Connect the terminal V2 test lead to conductor 2 Connect the terminal l1 current probe to conductor 1 Connect the terminal l2 current probe to conductor 2 e 8 v v2 V3 NAM 12 qi v V2 V3 NAM DC 4 Wire Connect the terminal N lead to the common conductor Connect the terminal V1 test lead to conductor 1 Connect the terminal V2 test lead to conductor 2 Connect the terminal V3 test lead to conductor 3 Connect the terminal l1 current probe to conductor 1 Connect the terminal l2 current probe to conductor 2 Connect the terminal I3 current probe to conductor 3 e e PRs v V2 V3 NAM 12 13 Repair and Calibration To ensure that your instrument meets factory specifications we recommend that it be scheduled back to our factory Service Center at one year intervals for recalibration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceab