1. C 4 F to 158 F Guarantee terms and conditions STABILA provides a guarantee against deficiencies and faults in the assured characteristics because of material or manufacturing faults for a period of 24 months from date of purchase Any faults will be eliminated at STABILA s own discretion either by repairing or replacing the unit STABILA accepts no en further claims No liability is accepted for any faults due to inappropriate treatment e g damage caused by the unit falling operation with the wrong voltage or type of current use of unsuitable current supply sources or for any autonomous changes made to the unit by the purchaser or a third party Also no claims under guarantee are accepted for natural wear and tear or any small faults that do not significantly affect the unit s operation Any guaran tee claims must be made via the dealer on the duly completed guarantee form see last page to be returned with the unit Notice for Canada This Class B digital device meets all requirements of Candian Radio Stan dards Specification RSS 210 FCC Statement Applicable in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in acc
2. STABILA sets standards REC 410 Line RF J Operating instructions en Operating instructions The STABILA REC 410 Line RF is a simple to use receiver for the rapid capture of laser lines The STABILA REC 410 Line RF can only receive pulse modulated laser beams The receiver will not work with rotation lasers We have ende avoured to explain the unit s handling and functioning in as clear and com prehensible manner as possible If however you still have any unanswered questions we should be pleased to provide advice over the telephone at any time on the following telephone number 0049 6346 309 0 Main components a b c d e f g h i ON OFF Volume Accuracy Automatic precision adjustment Manual precision adjustment Laser receiver glass Display LED display red yellow green line marks j k 0 Magnet for fixing the receiver directly to a metal surface Integrated steel plate to attach the receiver directly to the magnet of the bracket Beeper Battery compartment cover Fold out support for using the receiver a flat surface Vial Fold out indicator notch a q Audio signals b en Getting started Press the ON OFF button a An audio signal a brief flash from the display and the LEDs confirm that the receiver is switched on Press the ON OFF but ton a quickly once to switch the instrumen
3. a de www stabila de STABILA Inc 332 Industrial Drive South Elgin IL 60177 1 800 869 7460 www stabila com
4. ausing elec tromagnetic disturbances to other equipment WARNING Electromagnetic radiation can cause disturbances in other equipment Alt hough the product meets the strict regulations and standards which are in force in this respect STABILA cannot completely exclude the possibility that other equipment may be disturbed en CAUTION Disturbances caused by electromagnetic radiation can result in erroneous measurements Although the product meets the strict regulations and stan dards whichin this respect STABILA cannot completely exclude the possibi lity product may be disturbed by very intense electromagnetic radiation near radio transmitters two way radios or diesel generators Precautions Check the plausibility of results obtained under these conditions Technical data Working range up to 100 m 328 ft At 21 C under optimum Laser dependent atmospheric conditions Move o 328 ft as N 2 KG Accuracy 4 fine 1 0 mm 5 128 medium 3 0 mm 1 8 wide 5 0 mm 25 128 Detectable spectrum 610 700 nm Acoustic signals Loud 100 dBA Low 70 dBA Batteries 3 1 5V Mignon cells Alkaline Size AA LR6 Battery display Yes LCD symbol Operating life gt 50 hours of receiver operation 1000 activations of the buttons during remote operation Automatic Shut Off 30 minutes Operation temperature range 10 C to 50 C 14 F to 122 F Storage temperature range 20 C to 70
5. e gt Cleaning Please do not remove dust and dirt from the receiving or display window by using dry cloths or abrasive materials as this procedure scratches the win dows A soft cloth and mild soap and water are effective The unit can be cleaned under a tap or with a hose with a low water pressure Do not use any other fluids other than water or glass cleaner as they may attack polymer components Prohibited Uses Operation without instruction Operation other than the intended uses Opening the detector except the battery compartment Modification or conversion of the detector Important information The person in charge of the detector must understand the instructions in this manual and ensure other users do also Periodically carry out test measure ments particularly after the detector has been subjected to abnormal use and before and after important measurements gt Positioning and adjustment of the instrument When setting up the instrument take care that the laser beam does not pro duce any unwanted reflections from reflective surfaces These reflections may also be captured by the receiver and produce incorrect readings Recycling programme for our EU customers In accordance with the WEEE regulations STABILA provides a dis posal programme for electronic products at the end of their service life For more details please contact 0049 6346 309 0 en Responsibilities Manufacturer of th
6. e product STABILA Messger te Gustav Ullrich GmbH her einafter referred to as STABILA is responsible for supplying the product including the user manual and original accessories in a completely safe condition Person in charge of the product The person in charge of the product has the following duties To understand the safety instructions on the product and the instructions in the user manual To be familiar with local regulations relating to safety and accident prevention To inform STABILA immediately if the product and the application becomes unsafe WARNING The person responsible for the product must ensure that it is used in accordance with the instructions This person is also accountable for the trai ning and the deployment of personnel who use the product and for the safety of the equipment in use Hazards of Use WARNING The absence of instruction or the inadequate imparting of instruction can lead to incorrect or adverse use and can give rise to accidents with far reaching human material financial and environmental consequences Precautions All users must follow the safety directions given by the manufacturer and the directions of the person responsible for the product Electromagnetic Compatibility EMC The term Electromagnetic Compatability is taken to mean the capability of theproduct to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without c
7. h the laser transmitter 1 Switch off the laser transmitter button 1 1a 2 Press and hold down buttons 1c and 1d _ 1 3 Switch on the laser transmitter button 1 4 The laser transmitter is in registration mode 1d The LEDs red and green flash alternately 5 Press the button automatic precision alignment d on the REC 410 Line RF receiver d 6 The red and green LEDs on the laser transmitter will flash 3 times for 3 seconds Registration was successfully completed Replacing the batteries Battery display Open the battery compartment cover m in the direction of the arrow Insert new batteries as indicated by the symbols in the battery com partment 3 x 1 5V miniature alkaline batteries size AA LR6 Remove the batteries if the recei ver will not be used for a long period Protective casing Do not unscrew receiver Do not submerge into water Protected against dust penetration and against water jets from all directions according to IP65 70 100 20 69 o 19 Bracket a Magnet For securing the receiver b Reading reference The edge is in line and can therefore be used for taking accurate readings on levelling staffs en c Securing knob Turning the securing knob fixes releases the clamp with the receiver to from the levelling staff d Moveable clamping jaw for fixing to the levelling staff b Care and maintenanc
8. ordance with the instructions may cause harmful interference to radio communications How ever there is no guarantee that interference will not occur in a particular ins tallation If this equipment does cause harmful interference to radio or tele vision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING Changes or modifications not expressly approved by the manufacturer for compliance could void the user s authority to operate the equipment Automatic precision adjustment The range of wireless connections strongly dependents on the environ mental conditions Thus wireless transmitters e g WLAN or Bluetooth connections and operation directly on the ground can impair reception If the automatic alignment function will not start it is helpful to increase the height of the laser or the receiver USA Canada STABILA Messgerate Gustav Ullrich GmbH P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 76855 Annweiler Tel 49 0 63 46 309 0 Fax 49 0 63 46 309 480 e mail info stabil
9. reference lines edges or compo nents The laser transmitter continues to rotate automatically until the laser line is precisely in line with the recei ver Using the remote operation func tion the laser transmitter can be alig ned with the REC 410 Line RF within the range 5 The receiver must be registered with the laser for this to be pos sible Registration It is only sensible to use this function if the receiver is positioned on a flat surface particularly in conjunction with LA180L 1 Align the laser approximately with the receiver 2 Precision adjustment can be undertaken in two different operating modes A Semi automatic 4 Use the arrow buttons for precision adjustment in the required direc tion The laser transmitter will rotate in a single movement in the direction indicated e B Fully automatic The laser transmitter initially rotates to the limit of the operating range 5 and then moves in the opposite direction until it reaches the position where the maximum strength of laser signal is received B1 Simple mode The laser transmitter will rotate in a single movement until it reaches the position where the maximum strength of laser Oe signal is received en B2 Continuous mode Continuous independent rotation tracking of the receiver by the laser beam 7 Registering the receiver with the laser transmitter Registering the REC 410 Line RF receiver wit
10. t off If the instrument is not used it will automatically switch itself off after 30 minutes Display 9 display steps indicate the divergence from the centre of the laser line The central bar indica tes the in line position of the REC 410 Line RF The arrow increases in size as the distance from the in line position increases REC 410 Line RF 5 0 El V me iJe mie UJO UJO UJO JO UJO UJO m 01 Fe RR 2 75 3 13 23 3 13 13 HAT A U FR Ac fo Ao he he 7 EA L E E Im m fee ce Lo Llo Lao Flo Flo Flo Lie Me L L gt EA Medium pitched audio signal a constant audio signal in line High pitched audio signal too high gt back Low pitched audio signal too low gt forward Setting the volume The volume is increased decreased by repeatedly pressing the button b Loud 1 out 2 or soft 3 If the instrument is set to silent only a short beep is emitted when the laser beam is received 4 4 1 2 3 en Measuring modes Accuracy fine 1mm 5 128 wide 5 0 mm 25 128 2 medium 3 0 mm 1 8 Automatic precision adjustment Only operates in conjunction with a laser transmitter with the appropriate features The precision adjustment lt 40 m 131 ft function can be used for example to T align laser lines exactly with the requi red