Home
user manual for sesamo automations for swinging doors
Contents
1. 1 SAR PAA a PSE 1 Logic setting Z E e 8 y 2 2 radar 3 1 radar 4 Stop open io 5 5 Manual opening logic ee il 6 6 Stop close 4 7 Manual opening device 8 Browse command g S 9 Browse command 10 Confirm 11 Reset 7 8 9 10 11 e Stop Close the automatism controls the complete closure of the door wings In this logic the inputs START1 and START2 of the electronic control card are not monitored if present the electric locking system blocks the door wings e Stop Open the automatism controls the complete opening of the door wings n this logic the inputs START 1 and START2 of the electronic control card are not monitored e 2 radar Entry exit radar both the inputs START 1 and START 2 of the electronic controlcard are monitored A signal originating from a sensor connected to one of theseinputs triggers the opening and consequent closing of the door wings The electriclocking system if present never blocks the door wings e 1 radar Exit only radar only the input START 2 of the electronic control card is moni tored A signal originating from a sensor connected to this input triggers the open ing and consequent closing of the door wings The electric locking system if pres ent blocks the door wings every time that these reach the position of complete closure Manual opening the automatism controls the complete closure of the door wings In this logic the inputs START1 and START2 of the e
2. USER MANUAL i SESAMO SWINGING DOORS USER MANUAL FOR SESAMO AUTOMATIONS FOR SWINGING DOORS TYPE OF AUTOMATISM SERIAL NUMBER DATE Q Piuma Millennium Q SWINGO Purpose of the manual These instructions are intended for the manager or user of a SESAMO automatic doors installation In order to obtain the best performance from the automatism Sesamo recommends that you read and carefully follow the user instructions in this manual This device has been designed for the automation of swinging doors Any other use will be considered contrary to the use provided for by the manufacturer who therefore cannot be held responsible Do not tamper with or modify the internal equipment of the automatism or any of the safety devices provided in the control unit for any reason The manufacturer accepts no responsibility in the event the internal parts of the automatism are modified or tampered with or if safety devices are used in the system which are different from those indicated by the manufacturer Operation of the automatisms Power the automatism with the mains voltage of 230V The automatism carries out a low speed manoeuvre during which the length of the passageway is stored in the memory the wings will first open and then close stopping in the closed position At this point the automatism is ready to operate with modes that depend on the type of peripherals and accessories installed and the logic selected using the select
3. ance Cleaning Object procedures Painted surfaces Clean with soap and water Anodised surfaces Clean with non alkaline soap pH 5 5 7 and water Photocells Clean with a damp cloth Selectors Clean with a damp cloth Maintenance The maintenance interval on the SESAMO automatisms is determined by the intensity and conditions of use of the automation In high traffic installations airport entrances supermarkets shopping centres motorway service areas etc or installations operating under particularly demanding conditions exposure to corrosive agents near the sea in very windy locations wings subject to frequent impacts with moving objects such as shopping carts etc it is advisable to perform maintenance on a six month basis scheduled with a specialized technician In low traffic installations small businesses private offices residences operating rooms etc it is advisable to perform maintenance annually scheduled with a specialized technician MU_BA_EN 2 09 10
4. ectrical power is out the automatism runs with battery power The led blink to show a low charge battery level Installation with opening push button or with sensors without selector Once the opening push button is pressed or the detection sensors are activated the door carries out the opening manoeuvre with automatic reclosure after the pause USER MANUAL i SESAMO SWINGING DOORS Electronic key Through this accessory together with the wing locking device it is possible to close the wings from the outside regardless of the logic selected on the advanced or basic selector Any power failure following this closure will not cause the doors to open Each time the electronic key is inserted the automatism passes from a normal operation state to a closed and locked state and vice versa During the transition from the locked state to the normal operation state the wings perform a complete opening and closing manoeuvre so as to allow the entry of a person if necessary Operation in case of power failure with batteries installed Antipanic mode during a power failure the wings will stop in the open position from the advanced selector it is possible to select only the stop closed function Continuous operation when a power failure occurs the automatism continues to operate with the set logic until the batteries run down The choice of operation type is carried out during installation by a trained technician Cleaning and mainten
5. lectronic control card are not monitored and the electric locking system if pres ent blocks the door wings Pushing the manual comand button the automatism controls a complete opening and complete closure of the doors The led indicators indicate the logic currently active led lit up To change the logic press the SELECT key every time the key is pressed the led corresponding to the various logics lights up in sequence When the desired logic is reached the led blinks for a few seconds when the light remains on the control card acquires the new logic If the multislave option is active when change the logic you can select a single door select the number of the door or operate on every door connected select all USER MANUAL i SESAMO SWINGING DOORS Installation with the base selector D Manual opening device Q va Z 1 2 Stop close SOQQA 4 1 Radar 5 2 Radar PR Manual opening logic L ESC Esc QOH A RESET Reset Battery mode Stop Close the automatism controls the complete closure of the door wings In this logic the inputs START 1 and START2 of the electronic control card are not monitored if present the electric locking system blocks the door wings e Stop Open the automatism controls the complete opening of the door wings n this logic the inputs START 1 and START2 of the electronic control card are not monitored e 2 radar Entry exit radar bo
6. or it will carry out the automatic opening and closing of the doors so as to allow the continuous passage of people in complete safety The opening of the wings can be controlled by detection sensors by the advanced or basic selector and by the push buttons for the manual control the opening manoeuvre can be followed by a pause or by the automatic reclosing of the doors depending on the logic chosen see the description of the logics selector The pause of the wings in the open position facilitates the passage of people according to the needs of the customer the pause time can be adjusted during installation The closing of the wings occurs automatically at the end of the pause time at a slower speed than the opening The safety of the automatism is ensured by the photocells or active safety sensors that detect any presence of obstacles in the passage zone and prevent the reclosing of the wings if necessary For additional safety the automatism is equipped with a sophisticated microprocessor device that in case of danger limits the thrust force of the wings so as not to pose a hazard for the people in transit For safety reasons the automatism is designed so that it is always possible even during power failure and with no battery to manually move the wings after having released the locking device if installed with the special key USER MANUAL iS SESAMO SWINGING DOORS Installation with the advanced selector
7. th the inputs START 1 and START 2 of the electronic controlcard are monitored A signal originating from a sensor connected to one of theseinputs triggers the opening and consequent closing of the door wings The electriclocking system if present never blocks the door wings e 1 radar Exit only radar only the input START 2 of the electronic control card is moni tored A signal originating from a sensor connected to this input triggers the open ing and consequent closing of the door wings The electric locking system if present blocks the door wings every time that these reach the position of complete closure e Manual opening the automatism controls the complete closure of the door wings In this logic the inputs START1 and START2 of the electronic control card are not monitored and the electric locking system if present blocks the door wings The automatism controls a complete opening and complete closure of the doors when you push the manual opening button you try to open the door with the push amp go function active and without the electric locking system The led indicators indicate the logic currently active led lit up To change the logic press the SELECT key every time the key is pressed the led corresponding to the various logics lights up in sequence When the desired logic is reached the led blinks for a few seconds when the light remains on the control card acquires the new logic The battery led is on if the el
Download Pdf Manuals
Related Search
Related Contents
座安全に関するご注意 =防雨型器具です。 { い土 ニ几 ョー Spirit topLine 8120 - Schulthess Maschinen AG Airis LW105H Manual - Recambios, accesorios y repuestos Copyright © All rights reserved.
Failed to retrieve file