Home

PDF (272KB, English)

image

Contents

1. ID numbers 800 899 are in the contiguration software reserved for interfaces in DS 700 boxes i e are not available for user stations By ticking the INTERFACES SEARCH amp REFRESH button in the Interface screen of the ConfigurlT software all installed interface modules and their ID numbers appear in the List of Interfaces For each event the system administrator assigns interfaces to groups and if required adjusts the properties of each interface See general user manual for ASL Digital chapter D ConfigurlT In the unlikely event that your DS 700 box does not work properly it can be reset by pushing the RESET button on the front panel Quick Guide DS 700 January 2014 ASL Intercom BV 6 0 DS 700 FRONT PANEL CONTROLS DIGITAL DS 700 Interface box INTERCOM 1 On LED green When this LED is lit the internal power supply is activated 2 Mains LED yellow Indicates whether the DS 700 is connected to mains power 3 DISPLAY showing e Unit number of the DS 700 e Sections A B C and D e The ID and TYPE numbers of the on board interface modules e DETECTING MATRIX message during login procedure see user manual e NO SERVICE message during login procedure see user manual e THIS DS 700 IN USE etc See section 5 of this quick guide 4 MINI SWITCHES Two Mini Switches labelled and to be pushed using a pin or pen 5 RESET button 7 0 DS 700 REAR PANEL CONTROLS amp CONN
2. to mains power The DS 700 may be connected to a mains power outlet 100 240 V AC 50 60 Hz which provides at least 75 watts The outlet should have a clean earth Avoid using mains power outlets which also power dimmer controlled lighting equipment The wires in the mains lead are color coded green yellow Earth safety ground blue Neutral brown Live In case the wires in the mains lead do not correspond with the colored markings identifying the terminals in your mains plug proceed as follows To a string a maximum of 8 interface modules 2 fully loaded DS 700 s can be connected or any combination of interface modules and user stations to a maximum of 8 units It is not allowed to connect the DS 700 to the INTERCOM OUT connector of a DS 80 wall box nor to one of the INTERCOM OUT connectors of a DS 88 Hub After a matrix unit is switched on it sends a handshake signal to its 5 intercom lines strings This signal triggers an electronic switch in the DS 700 by which its power supply section is activated the green LED on the front panel is now lit As soon as a matrix unit is switched off the handshake signal disappears Now the power supply section of the DS 700 switches off and the green LED extinguishes If any damage has occurred please notify your dealer so that a written claim can be initiated Please also refer to the warranty section of this quick guide WARNING During installing or removing interfa
3. DIGITAL INTERCOM DS 700 INTERFACE BOX DS 700 Interface box QUICK GUIDE January 2014 This product is designed and manufactured by ASL Intercom B V Zonnebaan 42 3542 EG Utrecht The Netherlands Phone 31 0 30 2411901 Fax 31 0 30 2667373 E Mail info asl inter com Web www asl inter com 1 0 GENERAL DESCRIPTION In case the interface slots in the matrix units of a particular intercom system do not offer enough space for the number of the required interface modules the DS 700 with 4 interface slots labelled A D may be used The DS 700 has a built in power supply a control DSP and a display All types of ASL interface modules may be fitted ina DS 700 except for the DS 79 Emergency interface which should only be installed in the rear panel of a matrix unit The DS 700 is connected to an intercom line string via the INTERCOM IN connector The INTERCOM LINK OUT connector is to connect another DS 700 or several user stations to the same string daisy chaining 2 0 UNPACKING After unpacking the unit please inspect for any ohysical damage to the unit and retain the shipping carton and relevant packing materials for use should the unit need returning 3 0 INSTALLATION A vertical rack space of 1RU 1 75 44 5 mm is needed The rack must have adequate ventilation Forced cooling is not required 4 0 MAINS POWER amp SAFETY EARTH WARNING This appliance must be earthed Connecting
4. ECTORS 6 INTERFACE SLOTS These slots marked A B C and D are for installing any type of interface module except for the DS 79 Emergency Interface which should only be fitted in a matrix unit WARNING Do not try to install a Matrix Link Module in a DS 700 interface slot 7 INTERCOM IN connector Ethercon To connect the DS 700 to the intercom line string 8 INTERCOM LINK OUT connector Ethercon To daisy chain the intercom line string 9 MAINS connector fuse holder To connect the DS 700 to mains power For more information about the use of the DS 700 and its pin configurations see the ASL Digital General User Manual Ask ASL via info asl inter com 8 0 WARRANTY This unit is warranted by ASL Intercom to the Original end user purchaser against defects in workmanship and materials in its manufacture for a period of 12 months from date of shipment to the end user Faults arising from misuse unauthorised modifications or accidents are not covered by this warranty If the unit is faulty it should be sent in its original packing to the supplier or local ASL dealer with shipping prepaid A note must be included stating the faults found and a copy of the original Suppliers invoice PAGE 4 Quick Guide DS 700 October 2013 ASL Intercom BV
5. ce modules the DS 700 has to be disconnected from mains e The wire which is colored green yellow must be connected to the terminal in the plug which is marked with the letter E or by the ground symbol or is colored green e The wire which ts colored blue must be connected to the terminal which is marked with the letter N or colored black e The wire which is colored brown must be connected to the terminal which is marked with the letter L or colored red Safety Earth For personal safety and proper operation of the DS 700 the green yellow wire of the mains lead must always be connected to the electrical installation safety earth or ground This wire is in the DS 700 connected to all exposed metal surfaces Any rack framework into which this unit might be mounted is assumed to be connected to the same grounding circuit Quick Guide DS 700 January 2014 ASL Intercom BV 5 0 DS 700 UNIT NUMBERS INTERFACE ID NUMBERS DS 700 display If a DS 700 box is connected to an intercom line string its display shows its unit number in above picture 1 and 4 slot sections marked A B C and D If the DS 700 is fully loaded carrying 4 interface modules each section shows the ID number of each interface module These ID numbers are 800 801 802 and 803 and are linked to unit number 1 lf a DS 700 carries less than 4 interface modules for instance one in slot A and one in slot B the ID numb
6. ers relating to slot C and D are not used and therefore not shown in the display The display of a DS 700 also shows the type numbers e g DS71 or DS72 of its installed interfaces These type numbers are embedded in the hardware of all interface modules If in an intercom system a second DS 700 is installed unit number 1 has to be changed to 2 by using the mini switch next to the display If that DS 700 is fully loaded the ID number range 804 807 appears in the display Same for a third DS 700 getting ID number range 808 811 and so on in case of more DS 700 boxes If by mistake two DS 700 boxes in the intercom system are given the same unit number the display of one of these DS 700 boxes shows THIS DS 700 IN USE PUSH THE BUTTONS Once you push such a button mini switch to enter another unit number the display shows TRYING TO LOG IN WITH After a while the interface modules in the DS 700 are logged in with their new ID numbers and the DS 700 returns to normal operation Each DS 700 memorizes its previously entered unit number and therefore the ID number range linked to that unit number When a DS 700 has been used in an intercom system and is then installed in another system its display shows after the unit is connected to a string its previously entered unit number and ID number range Often the unit number has now to be adjusted for the other system by using the or mini switch The