User Manual for the interfaces "is HRT USB" and "is
Contents
1. add a device to your configuration Select the device and make your settings Use the Remove Button to remove a selected device from your configuration Add Remove ifak system GmbH 15 Software Installation and Configuration is HRT USB is HRT 5 Add a Device Please press the button Add choose the device type you would like to add Then make your settings Figure 4 Configuration software add a device Add Device x Select device type YD Pel OF i EmptySlot Device is HRT USB is HRT USBeX The device possesses an unique serial number for clear identifi cation The number is located on the downside of the case The configuration software offers the possibility to search automati cally for all attached devices and to detect their serial numbers Please fill in the number in the intended field The device can work like a serial modem under the operating systems Windows 2000 and XP Therefore it offers a serial COM port so that already existing applications can be used with out any changes The serial COM port can be selected The configuration software checks the available COM ports to avoid an address conflict 16 ifak system GmbH is HRT USB is HRT USBeX Configuration Software Figure 5 Configuration software select a serial COM port B isHaRT Driver Configuration E Devices Device USB _isHART Driver Configurati
2. 1 Driver installation The driver software has to be installed before the hardware installation Otherwise the operating system can t find the respective driver 2 Under Windows NT 4 0 reboot the PC 3 Interface installation 4 Configuration The interface can be connected to the HART network with the pin test clips directly With the integrated USB cable the interface can be connected with the PC notebook The green LED indicates the actual operating mode It flashes during the start up reset process After the end of the reset pro cess the LED should darken again ifak system GmbH 9 Hardware Installation is HRT USB is HRT USBexX 10 ifak system GmbH is HRT USB is HRT USBexX Software Installation CHAPTER 2 SOFTWARE INSTALLATION AND CONFIGURATION Software Installation The driver software has to be installed before the hardware installation Otherwise the operating system can t find the respective driver The driver software package is HRT Multidriver contains a Dynamic Link Library DLL which allows the access to the HART firmware under the operating systems Windows 9x ME NT 4 0 2000 and XP The actual operating system is detected automatically by the driver DLL The configuration of the interface can be done fast and easily with the configuration software is HRT Driver Configurator which is installed into the ifak system directory of the Start Menu The software comes on CD ROM The installati
3. Member States relating to the electromagnetic compatibility 89 336 EEC Tested according to EN55022 Class B and EN55024 Serial 4000 5999 Changes or modifications not approved by ifak system void the validity of the declaration A copy of the signed Certificate of Conformity can be requested at the above address ifak system GmbH 5 Hardware Installation is HRT USB is HRT USBexX ATEX Certificate for is HRT USBex The interface type is HRT USBeX has been tested for the use in potentially explosive atmospheres according to the Directive 94 9 CERT Certification Body has certified that the type meets the provisions of the Directive in the essential health and safety requirements for the conceptional design and manufactur ing of equipment protection systems and devices set out in Annex II of the Directive account being taken of their intended use in potentially explosive atmosphere The EC equipment type examination number is TUV 04 ATEX 2503 The interface type was tested according to EN 50014 1998 Al A2 and EN 50020 2002 On the product following information must be given 1 2 EEx 6 ifak system GmbH is HRT USB is HRT USBeX PC Connection PC Connection System Requirements To connect the interface is HRT USB or is HRT USBexX with your computer an available USB port is required The operating sys tems Windows 9x ME NT 4 0 2000 and XP are support
4. SB is HRT USBeX umentation refer to both device types otherwise a particular type is named specially Figure 2 The intrinsic safe interface is HRT USBeX is HRT usBeX HART USB Interface The interface supports the transmission speed of 1200 bit s and can work as primary Master as well as secondary Master The interface is available with opto isolation to the HART network The device comes with a Windows DLL which allows the easy integration of the modem into any applications The device can work like a serial modem under the operation systems Windows 2000 and XP Therefore it offers a serial COM port so that already existing applications can be used without any changes Optionally a device type manager DTM compliant to the cur rent version 1 2 of the FDT specification is delivered It works like a device driver witch allows the communication between devices on the HART bus and their DTMs With the help of the DTM the start up process of the HART bus can be done easily 2 ifak system GmbH is HRT USB is HRT USBexX Introduction Documentation This documentation contains important information for the secure and correct operation of the interfaces is HRT USB and is HRT Please read this documentation carefully before using the device Throughout the manual different fonts are used to indicate differ ent meanings A short explanation can be found below Courier New file names
5. TECHNOLOGIEN MIT VORSPRUNG is HRT USB is HRT USBeX User Manual RR 2 SSD ifak system Copyright ifak system GmbH 2005 all rights reserved No part of this work may be reproduced in any form or by any means graphic electronic or mechanical including photocopying recording taping or storage in an information retrieval system without prior written permission of the ifak system GmbH Information in this manual is subject to change without notice and does not represent a commitment of the ifak system GmbH ifak system GmbH Oststrasse 18 D 39114 Magdeburg Germany www ifak system com1 Tel 49 391 544 563 10 Fax 49 391 544 563 99 Email hart ifak system com is HRT USB is HRT USBexX Contents Contents Chapter 1 Hardware Installation Introduction Stand Skeet 2 1 Documentation gt Sad 3 OUR Sit 3 Certificates iu wetiee teed tee ee ea 4 EMC Certificate 4 EMC Certificate of Conformity for is HRT USB 4 EMC Certificate of Conformity for is HRT USBex 5 ATEX Certificate for is HRT USBeX 6 PC Connection Bake 7 System Requirements 7 Delivery Contents 0 eee 7 TechnicalData 8 Installation s 9 Steps o
6. ables a free enumeration of devices by inserting empty devices between existing ones Figure 7 Configuration software add an empty slot R _isHART Driver Configuration x _isHART Driver Configuration Device Empty gt Device 0 USB Device Device 1 empty You can use an Empty Slotto reserve device numbers Add Device x Ifyou want to configure a device as Device 6 and you don t want a Device Select device type 5 you insert this type OPC POCA EmptySlot OK Cancel Remove a Device Mark the device you wish to remove and press the button Remove 18 ifak system GmbH
7. code sequences Arial names commands remarks Our Service In case you have any questions which can t be solved by this manual please contact our service by phone fax or e mail ifak system GmbH Oststrasse 18 D 39114 Magdeburg Germany www ifak system com Tel 49 391 544 563 10 Fax 49 391 544 563 99 e mail hart ifak system com ifak system GmbH 3 Hardware Installation is HRT USB is HRT USBexX Certificates EMC Certificate EMC Certificate of Conformity for is HRT USB We the producers ifak system GmbH Oststrasse 18 D 39114 Magdeburg certify hereby that the product is HRT USB meets the protection requirements of the European Union council directive of 3 May 1989 on the approximation of the laws of the Member States relating to the electromagnetic compatibility 89 336 EEC Tested according to EN55022 Class B and EN55024 Serial no 2000 3999 Changes or modifications not approved by ifak system void the validity of the declaration A copy of the signed Certificate of Conformity can be requested at the above address 4 ifak system GmbH is HRT USB is HRT USBexX Certificates EMC Certificate of Conformity for is HRT USBexX We the producers ifak system GmbH Oststrasse 18 D 39114 Magdeburg certify hereby that the product is HRT USBeX meets the protec tion requirements of the European Union council directive of 3 May 1989 on the approximation of the laws of the
8. ed Delivery Contents The interfaces are delivered with user manual and driver soft ware on CD Driver for the operating system Windows NT 4 0 is delivered only on request ifak system GmbH 7 Hardware Installation is HRT USB is HRT USBex Technical Data Attention Table 1 Hardware capabilities Hardware Modem Chip is HRT USB Modem Chip is HRT USBex Connector Transmission speed Maximal output values Test voltage of opto isolation HART H amp B 0743849 HT 2012 2 pin test clips 1200 bit s 1 0 V lo 7 mA 7 mW 3 KV Connector Input values Transmission speed Operation USB 1 device connector Uin 5 V 10 5 5 V lin Max 200 Pin 1 W Um 253 12 Mbit s up to 16 devices in parallel Table 2 Software capabilities Driver Interfaces Operating systems DLL Windows 9x ME 2000 XP Windows NT 4 0 on request Product changes which are not approved by ifak system result in a voidness of the Certificate of Conformity Intrinsic safe device Only the HART connector test clips can be led into the explosive area The device is HRT USBeX can t ifak system GmbH is HRT USB is HRT USBexX PC Connection never be used in a potentially explosive area An unauthorised opening of the device expires the operating license for the use in explosive area Installation Steps of Installation
9. f Installation 9 Chapter 2 Software Installation and Configuration Software Installation 11 Installation under Windows NT 4 0 12 Install6d FileS Setiego iaaa ee ee at 13 Configuration Software 15 Adda DEVICE n reana aaae tnd die alta kb oh 16 Device is HRT USB is HRT USBeX 16 Configuration under Windows NT 4 0 17 Emipty Slot Gee erotic 18 Remove a Device 18 ifak system GmbH 1 is HRT USB is HRT USBex II ifak system GmbH is HRT USB is HRT USBexX Introduction CHAPTER 1 HARDWARE INSTALLATION Introduction The advantages of the Universal Serial Bus USB combined with the operational range of HART these practically orientated features turn the device is HRT USB in a state of the art fieldbus component Desktop PCs as well as notebook devices without HART interfaces can be made HART nodes within seconds based on the plug amp play features of USB The device is bus powered thus not depending on external power connections Figure 1 The HART interface is HRT USB For the use in hazardous areas we deliver an intrinsic safe ATEX certified version is HRT USBex It is functionally equivalent to the standard type is HRT USB All information given in this doc ifak system GmbH 1 Hardware Installation is HRT U
10. on Device 0 USB Device Serial No 2005 Search attached device provide serial COM port Serial port COM2 Add Remove Cancel If you are working under Windows 98 ME XP or 2000 just fill in your settings and end with OK Configuration under Windows NT 4 0 For licence reasons the using of the USB driver stack under NT 4 0 is protected by a licence number The licence number is only valid for that single device The number is put down on the inside of the documentation NT 4 0 USB Extension 1996 2000 BlueWater Systems Inc Figure 6 Configuration software input of serial and licence number 5_isHART Driver Configuration x r Devices s _isHART Driver Configuration Device USB gt Device 0 USB Device gt Device 1 USB Device Serial No 2001 Search attached device Licence number 1511 605 10 9 973 Add Remove When adding a device for the first time under Windows NT 4 0 the program checks whether the driver software has been ifak system GmbH 17 Software Installation and Configuration is HRT USB is HRT USBex installed correctly and then enables the stack functionality Therefore it is necessary to reboot the PC Under the operating system Windows NT 4 0 the device can not work as a serial modem Empty Slot The empty device does not contain any resources It serves as a substitute for device numbers not yet assigned Using empty slots en
11. on follows the steps mentioned below e Login as administrator under the operating systems Windows NT 4 0 2000 and XP e Insert the installation CD ROM into your CD drive The setup starts with an autoroutine proceed according to the instructions displayed on the screen The software is installed in the default program directory of your computer under the subdirectory ifak system is HRT Multidriver ifak system GmbH 11 Software Installation and Configuration is HRT USB is HRT 5 Installation under Windows NT 4 0 For a correct operation of the device it is necessary to install the driver software including the NT 4 0 USB stack to configure the hardware and to reboot the PC only in the order subsequently described 1 Install the driver software setup 2 Boot the PC 3 Start the configuration program is HRT Driver Configurator and change the device settings according to your hardware 4 Close the configuration program 5 Reboot the PC 12 ifak system GmbH is HRT USB is HRT USBeX Software Installation Installed Files Depending on the operating system the following files are installed on your computer Table 3 Installed files nt4 isHARTusbNT4 sys W2000 isHARTusb sys W2000 isHARTusbW2000 inf W98 isHARTusb sys W98 isHARTusb inf DLL isHARTdrv dll the Dynamic Link Library providing access to the firmware driver DLL isHARTd rv lib the corresponding lib
12. rary for C C envi ronments INC isHARTdrv h definition of software interface and error codes USB Driver provides the access to the USB stack under Win NT 4 0 provides the access to the USB stack under Win 2000 and XP installation information for Win 2000 and XP provides the access to the USB stack under Win 98 and ME installation information for Win 98 USB Stack NT 4 0 USB Extension provides USB support for NT 4 0 Configuration Software bin HARTDriverConfig exe Setup Program NT 4 0 USB Extension 1996 2000 BlueWater Systems Inc ifak system GmbH 13 Software Installation and Configuration is HRT USB is HRT USBex 14 ifak system GmbH is HRT USB is HRT USBex Configuration Software Configuration Software The configuration software is HRT Driver Configurator is pro vided in order to adapt the DLL access to your hardware It is installed in the Start Menu This dialog based application allows the easy addition and removal of HART interfaces It also checks the available resources of the system A device number is assigned to each USB interface which ena bles the software to address it Empty devices can be included in order to allow gaps in the enumeration of devices see section Empty Slot Figure 3 Configuration program add and remove devices isHART Driver Configuration _isHART Driver Configuration Device Use the Add Button to