Home

user manual

image

Contents

1. Press A key or V key to adjust the value each press means increase or reduce 0 1V Press ENTER to choose 11 3 Press ENTER key to next page V5 floating charge voltage T1 1 Linel whole power output Press A key or V key to adjust the number each press means increase or reduce 0 1V If set time each press means increase or reduce 1 hour while setting time Press ENTER to choose 11 4 Press ENTER key to next page T1 2 Linel half power output time T1 3 Linel Turn off output time Press A key or V key to adjust the number each press means increase or reduce 1 hour Press ENTER to choose Page 14 Specification of excellent controller 11 5 Press ENTER key to next page T2 1 Line2 whole power output time T2 2 Line2 half power output time Press A key or V key to adjust the number each press means increase or reduce hour Press ENTER to choose 11 6 Press ENTER key to next page T2 3 Line2 Turn off output time VsTH DC power output turn on while voltage of solar panel lower than this value and turn off while solar panel voltage higher than it T2 3 xxh VsTH xxV Press A key or V key to adjust the number each press means increase or reduce hour If set voltage each press means increase or reduce 1V Press ENTER to choose 11 7 Press ENTER key to next page VwCH xxV MODE X 11 7 1
2. WwTH this value is mean controller would rise voltage of wind turbine to charge battery Please be mind if your system are 24V will showing is 12v it was rectified value wind turbine output approximate 10vac 12v system will showing6 0v wind turbine output approximate 6vac Press A key or V key to adjust the number each press means increase or reduce 1 0V A CAUTION This parameter must be modify by professional technician general user re setting is prohibited 11 7 2 Mode parameter is meaning different system Press A key or V key to choose mode type according to actual your system correctly Page 15 Specification of excellent controller 11 8 Press ENTER key to next page Save Y N If you have selected Y and press Enter key controller will save value which you modified If you have selected N controller wouldn t save what your adjustment Saved gt gt gt gt gt gt Then approximate 2seconds later LCD will back to show first page of browsing window content A CAUTION When you have completed all setting please to do disconnection battery aim to power off controller Then 10seconds later re start connection of battery to power up controller This is intent to make sure the program running in you done modified setting condition _ PLEASE MAKE SURE NO CONNECTIION WITH WIND TURBINE AND SOLAR PANEL BEFORE SETTING 11 9 wind turb
3. For 12V system battery voltage must be greater than 9V The controller will identify system by detection of this parameter If the battery voltage is between 16V 17V the controller is in discriminant blind spot the controller will not work normally please be noted Page 6 Specification of excellent controller CONTROLLER WIND amp SOLAR HYBIRD C 2 oe Figure 8 2 MPPI Charge 12V724V Auto 6 eataa BATTERY Wire an in line fuse holder no more than 150mm from the battery positive terminal Confirm the connection are correct Step 2 Loading Wiring The controller load output can connect DC electronic devices of which rated voltage is same as battery s Device will provide battery voltage to the loads DC loading could be LED lamp or monitor devices etc CONTROLLER WIND amp SOLAR HYBIRD Figure 8 3 1 Connect loadl positive and negative to the controller related terminals and connect load2 positive and negative to the controller related terminals accordingly 2 The load terminals may exist voltage connect carefully to avoid short circuit 3 An in line fuse holder should be wired in series in the load positive or negative wire as shown Do not insert a fuse at this time Page 7 Specification of excellent controller 4 Confirm the connections are correct If wiring the load connection to a load distribution panel each load circuit should be
4. System is initial Please wait 9 2 2 Then LCD screen will show Ist page content of screen Ub voltage of batteries Eb xxx Eb mean power volume of battery with percent format Uw meaning voltage of wind turbine but this value is DC voltage which be rectified voltage from wind turbine output Iw charging current from wind turbine to battery Us mean solar panel voltage charging current from solar panel to battery Output is turn on will show ON night and if output was turn off will show OFF day characters It will show normal while battery voltage is good condition and will show float when floating charge states BATTERY normal If you stop pressing any key for 60 seconds approximately the LCD would showing back to first browsing page content Page 12 Specification of excellent controller 10 LCD display when system abnormal situation e If the battery is overcharge the LCD display Uplink displays the current battery voltage Downlink display over_v characters which be flashing Ub xx x V over_V Tip Once the battery voltage drops to the overcharge recovery value the LCD is automatically back to first browsing page content e If the battery voltage is under voltage the LCD display Uplink displays the current battery Downlink display low_v character which be flashing Tip Once the battery voltage rise to the discharge recover
5. e 12V 24V Auto 1 There are 2 wires from controller need connect to switch power Red wire is positive Black wire is negative polarity 2 Please make sure connection are correct with switch power related terminals 3 Switch power AC input terminal please connect with your city electric Please refer to instruction from manufacturer of switch power AN CAUTION reverse polarity connection was prohibited Step 6 Accessories Option If your buy unit isn t this type mode please ignore following guide Please skip to next step 7 Install the data communication wire if required 2 Refer to the instructions provided for detailed installation procedures of software guide Page 9 Specification of excellent controller Figure 8 7 Step 7 Confirmation for Wirin Double check the wiring in step through 5 Confirm correct polarity at each connection Verify that all 10 power terminals are tightened CONTROLLER WIND amp SOLAR HYBIRD mal oe MPPT Charge Figure 8 8 12V 24V Auto Step 8 Power up sequence after confirmation of connection Turn on battery firstly Turn on solar panel Turn on wind turbine Turn on DC loading Turn on switch power for city electric if be this mode oa iS AN CAUTION if you would take down system as need must be comply with following sequence 1 Remove wind turbine wiring firstly Page 10 Specification of excellent controller 2 Remove
6. solar panel wiring 3 Remove DC load wiring 4 Remove batteries wiring lastly When battery power is applied and the controller powers up the LCD will showing message as system initial please wait Meantime backlight is lighting in green approximate 5 seconds then backlight would turn off System is initial Please wait If the controller does not power up or LCD will not lighting please refer to following section troubleshooting 1 Double check battery connection whether be correct and tight 2 Make sure battery voltage higher than 9V 3 Controller DC power output have one 1 minute delay 4 If battery voltage lower than over discharge point no DC power output 5 As street lighting system while solar panel voltage higher than threshold voltage controller no DC power output LCD backlight is on after pressing any key The backlight will last 15 seconds then would be power off if you stop press any key long time 9 1 Description of Key Press A key In browsing window press this key to back previous page content of LCD showing Vv key In browsing window press this key to look next page content of LCD showing 9 2 Displayed Content Description 9 2 1 while battery connected with controller and power up then LCD would showing content as system is initial please wait and last approximate 3 seconds with backlight Page 11 Specification of excellent controller
7. N a Ta 20 Dimensions mm Net weight 1 2KG L 152 Page 21
8. Specification of excellent controller Z00W 600 W series User Manual wind solar hybrid Controller Model No SSWC 06 1224 TA Version 5 0 Thank you very much for selecting our product This manual offers important information and suggestions with respect to installation use and troubleshooting etc Please read this manual carefully before using the product and pay attention to the safety recommendations in it ANDAR WN 9 10 11 12 13 14 15 16 17 18 19 20 Specification of excellent controller Contents Important Safety Operation Information cc eee General Safety Information 0 ccc cece cece cece cece ee ee eee eee eens General WESCMplUO Mic Secinn annette al Product Teal Brener n a nied ade centetmacni N Protection F nctionSssra aar RA A E OTUN Controller application mode illumination 0 cece eee e eee Instruction for panel of controller c ccc cece cece eee e eee e es Installation Instructions 8 1 General Installation Notes cece ccc cece nec cc eee eee eeees G2 MODNE wtcacdeseect teva A ER 8 3 System connection with controller SEPI Battery Wiis erae tet ce deh ceunechcaend EE E Sep 2 Loadine WIDE naei tea len dcnewhenctenadaoseuie eeoter iia dee step 3 Solar Module W iting p i555550 etniniais lt isa ches Step 4 Wind turbine PMG Wiring 0 ccc cece cece cece eens Step 5 Switch pOW
9. Specification of excellent controller _ Step 1 Choose Mounting Location Locate the controller on a vertical surface protected from direct sun high temperature and water _ Step 2 Check for Clearance Place the controller in the location where it will be mounted Verify that there is sufficient room to run wires and that there is sufficient room above and below the controller for air flow Step 3 Mark Holes Use a pencil or pen to mark the four 4 mounting hole locations on the mounting surface _ Step 4 Drill Holes Remove the controller and drill four sizeable holes in the marked locations Step 5 Secure Controller Place the controller on the surface and align the mounting holes with the drilled holes in step 4 Secure the controller in place using the mounting screws 8 3 System connection with controller CF NOTE A recommended connection sequence has been provided for maximum safety during installation Figure 8 1 e tan Ki DC OUTPUT BATTERY WIND INPUT SOLAR INPUT o ws w de a Step 1 Battery Wirin WARNING Risk of explosion or fire Never short circuit battery positive and negative or cables If your battery voltage lower than 9V connect to controller is prohibited Controller was damaged much possibly caused by this occurrence AN CAUTION 1 Before connecting the battery please measure the battery voltage 2 For 24V system batteries voltage must be greater than 18V 3
10. above sea level RS232 RS485 USB be optional Page 18 Specification of excellent controller 15 Model Description S S5 W C 06 1224 T gt Top advanced r Battery voltage 12V 24V AUTO Wind turbine Max power 600W controller wind solar Company code 16 Maintenance The following inspections and maintenance tasks are recommended at least two times per year for best controller performance e Check that the controller is securely mounted in a clean and dry environment e Check that the air flow and ventilation around the controller is not blocked Clear all dirt or fragments on the heat sink e Check all the naked wires to make sure insulation is not damaged for serious polarization frictional wear dryness insects or rats etc Maintain or replace the wires if necessary e Tighten all the terminals Inspect for loose broken or burnt wire connections e Check and confirm that LCD is consistent with required Pay attention to any troubleshooting or error indication Take necessary corrective action e Confirm that all the system components are ground connected tightly and correctly e Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten terminal screws to the suggested torque e Inspect for dirt insects and corrosion and clear up e Check and confirm that lighting arrester is in good condition Replace a new one in time to avoid damagin
11. battery voltage lower than 9V connect to controller is prohibited Controller was damaged much possibly caused by this occurrence Solar panel and loading rated power do not higher than controller rating accordingly 2 General Safety Information Please don t use low quality battery to avoid leakage rust or burn Please don t use thin or low quality cable to avoid leakage or fire Do not open cover and maintain personally Keep it away from water moist rain severe dust shaking corrosion and Intensive or under intense electromagnetic interference This machine prohibited around the place with any flammable explosive and dangerous goods Keep any symbols on the controller complete To avoid accidents keep it away from this children 3 General Description The advanced wind solar hybrid controller is specially designed for high end small scale wind solar hybrid system and especially suitable for wind solar hybrid street light system and wind solar hybrid monitoring system Topology Diagram Page 3 Specification of excellent controller 4 Product features MPPT technology to optimize using the wind energy Optional Boost circuit designed User can set this voltage parameter Optional 12V 24V System automatic recognition function Optional Be able to use for 200W 600W wind turbine with high compatibility Digital design module structure stable and reliable Dual line output light sensor and timer functio
12. er WIPTING 00cccsececscesecceweaveusecseraccenaees Step 6 Accessories Option 545522526 h i eee ta shen oieececden totes Aeneneaes Step 7 Confirmation for Wiring cece cece ecee eee ee cece eee eens Step Os POWer Up sege NCE inciichtconiatannesebes aG VCD Browsins Ins truCh Ons ereere aena A NTa 10 LCD display when system abnormal situation 0 00008 12 System Setting Instructions ccc cece cece eee e eee e cece cece cece eeeees 13 Controller working mode instruction cceeeeeeeeeeee eens 15 About time delay illumination ccc cc cecee sence eee eeeeeeeeeees 16 Performance Parameters orereta ea o ae a 17 Model Description serere T E a 18 Mantenan OX as actin Sy ceased EE EE 18 Troubleshootuns Guides sorisa ae ratee ete nt aioe ei 19 Warmranty and after Sales Service coschscasstugeiuarensrdes hates actonus 19 Dor aeee a a E 20 DIMENSIONS aaisen a aa ER AE 20 Page 2 Specification of excellent controller 1 Important Safety Operation Information This manual contains important safety installation and operating instructions for controller ZN WARNING Reverse connection of positive and negative is prohibited Short circuit of positive and negative is prohibited DC supply switching power supply or motor driven generator to simulate the wind generator to charge testing is prohibited N CAUTION If your
13. esh water available to wash and clean any contact with battery acid e Uses insulated tools and avoid placing metal objects near the batteries e Explosive battery gasses may be present during charging Be certain there is sufficient ventilation to release the gasses e Avoid direct sunlight and do not install in locations where water can enter the controller e Loose power connections and or corroded wires may result in resistive connections that melt wire insulation burn surrounding materials or even cause fire Ensure tight connections and use cable clamps to secure cables and prevent them from swaying in mobile applications e Use with Gel Sealed or Flooded batteries only e Battery connection may be wired to one battery or a bank of batteries The following instructions refer to a singular battery but it is implied that the battery connection can be made to either one battery or a group of batteries in a battery bank e Select the system cables according to 3A mm current density 8 2 Mounting F NOTE When mounting the controller ensure free air through the controller heat sink fins There should be at least 150mm of clearance above and below the controller to allow for cooling If mounted in an enclosure ventilation is highly recommended A WARNING Risk of explosion Never install the controller in a sealed enclose with flooded batteries Do not install in a confined area where battery gas can accumulate Page 5
14. fused separately The total load draw current should not exceed the 10A load rating Step 3 Solar Module Wirin N WARNING Risk of electric shock Exercise caution when handling solar wiring The solar module s high voltage output can cause severe shock or injury Cover the solar module s from the sun before installing solar wiring A CAUTION 1 If you can not confirm the scientific and rational PV module connection by series or parallel way please contact the manufacturer of controller 2 The controller can be applied to the single crystal silicon polycrystalline silicon thin film photo voltaic group 3 PV groups open circuit voltage Voc do not higher than rated battery bank voltage 2 0times 4 PV groups operation voltage Vmp do not lower than rated battery bank voltage 1 2times CONTROLLER WIND amp SOLAR HYBIRD Figure 8 4 E Le me MPPI Charge 12V 24V Figure 8 5 Specification of excellent controller 7 NOTE _ The wind turbine rated voltage rated wind speed level should be equal to voltage of battery bank If your wind turbine output is DC power polarity wire can connect to 2 of whereby 3 terminals be optional Please connect wind turbine to controller related terminals Step 5 Switch power wiring If your buy unit isn t this type mode please ignore following guide Please skip to next step 6 CONTROLLER Figure 8 6 WIND amp SOLAR HYBIRD ml me MPPI Charg
15. g of the controller and even other equipments AN Warning Risk of electric shock Make sure all the power is turned off before above operations and then follow the corresponding inspections and operations Page 19 Specification of excellent controller 17 Troubleshooting Guide i Fault Phenomenon Reason 1 Connected to the The battery voltage is too Charger to charge battery the controller low the battery or does not work replace the batter The battery voltage is below Normal ihe for the the release point system to charge to the recovery point 2 Connected to the battery the controller Access photovoltaic panels Remove the does not output Switch on PV photovoltaic panels Controller is 1 minute output delay battery voltage is Normal normal The voltage of Wind turbine Observe When and photovoltaic panels Wind or PV is The controller is not too low strong enough charging The battery voltage is too high has been in the Normal overvoltage condition Still no output when Batteries rose toa The controller has two observe and test recovery point from minutes delayed output after 1 minute over discharge point Observe When The wind speed is too low a taen The battery is not connected the controller starts the Securely connected open circuit protection again function The battery voltage is too high has been in the brake condition The speed of the wind turbine is very low Observe after t
16. he Battery discharge 18 Warranty and after Sales Service The charge controller is warranted to be free from defects for a period of ONE 1 years from the date of shipment to the original end user We will at its option repair or replace any such defective products e Claim procedure Before requesting warranty service check the Operation Manual to be certain that there is a problem with the controller Return the defective product to us with shipping charges prepaid if problem cannot be solved Provide proof of date and place of purchase To obtain rapid service under this warranty the Page 20 Specification of excellent controller returned products must include the model serial number and detailed reason for the failure the module type and size type of batteries and system loads This information is critical to a rapid disposition of your warranty claim e This warranty does not apply under the following conditions Damage by accident negligence abuse or improper use PV or load current exceeding the rating of product Unauthorized product modification attempted repair Damage occurring during shipment Damage results from acts of nature such as lightning weather extremes Irreclaimable mechanical damage 19 Declare The product has applied for patent protection counterfeiting will be subject to legal sanctions Our Company reserves the right to change products and without notice when products update O
17. ine brake function This advanced controller have manual operation for wind turbine brake while you have maintenance or repair wind turbine Please Press constantly A key and key with simultaneity Then your wind turbine would slow running gradually to stop If you stop press keys then brake will be abated 12 Controller working mode instruction 12 1 Mode A Street lighting system Ith and 2 line output are full power halt power turn off morning lighting J T1 1 fullpower Q T1 2halfpower Tl 3 tum off Q T1 4 moming lighting y dusk light on dawn light off Page 16 Specification of excellent controller NOTE 1 When solar module voltage goes below the point of NTTV Night Time Threshold Voltage at sunset the solar controller will recognize the starting voltage and turn on the load after 1 minutes delay 2 When solar module voltage goes above point of DTTV Day Time Threshold Voltage the solar controller will recognize the starting voltage and turn off the load after 1 minutes delay 3 We set NTTV equal to DTTV by VsTH this parameter to adjust T1 X mean 1th line output T2 X mean 2 line output for example T1 X e Tl 1 default is 5 mean full power time is 5hours then go intoT 1 2 step e T1 2 default is O mean half power time is Ohours then go intoT1 3 step directly e T1 3 default value be 5 mean turn off time is 5hours then go intoT 1 4 step e T1 4 this process
18. is balance of whole night time And turn off lamp while dawn This value would not show on LCD so this value is not adjustable Of course you could to cover this process by 2 3 value with longer time 12 2 DC output constant MODE C Such so mode control way is for monitor system On this mode related street lighting function will be shut down DC power will be output constant with 24hours 13 About time delay illumination Over discharge cut off output 10 seconds approximately Over discharge recovery for output 2 minutes approximately Loading abnormally output DC power 2 minutes approximately Wind turbine brake 1 hours approximately Page 17 Specification of excellent controller 14 Performance Parameters 14 1 Wind generator control set up definition Rated Wind Turbine Power 200W 600W Wind Turbine brake voltage 12v 24v ISVAC 25VAC 14 2 Solar panel set up definition SOW 508 14 3 Battery management definition 13 5V 27 0V 14 4 Output Set up function Each Line Output Current rating A Each Line Output rated Power 12V 24V 60W 120W Dusk and dawn threshold voltage VsTH default 6 0V 14 5 Product Conventional parameter Display LCD with backlight adjustable adjustable adjustable adjustable O O Self consumption 30mA backlight turn off Temperature compensation coefficient 35mV C 25 C ref Ambient temp range 30 C to 55 C lt 5000 meters
19. ns morning lighting constantly output 24hours e User can adjust setting of system parameters as voltage protection point boost voltage light sensor voltage timer and so on 5 Protection Functions Solar cells reverse charging solar cells anti reverse connection Battery over charging over discharge battery anti reverse connection Over load load anti reverse connection and load short circuit protection Wind turbine current and voltage limited rotation limited and brake 6 Controller application mode illumination This device be able to be using several type systems as following If your buy is city electric supply type as following mode How to set MODE A C B D please refer to 11 7 section guide 7 Instruction for panel of controller CONTROLLER WIND amp SOLAR HYBIRD eee MPPT Charge Page 4 Specification of excellent controller 1 Wiring connection with system terminals 2 LCD with green backlight 8 A setting key to increase value of parameters 4 Esc key for existing system without save setting W setting key to reduce value of parameters Enter key to process setting condition or save modification of parameters 8 Installation Instructions 8 1 General Installation Notes e Read through the entire installation section first before beginning installation e Be very careful when working with batteries Wear eye protection Have fr
20. y value the LCD is automatically back to first browsing page content e If loading overload over current short circuit the LCD display The screen display over_A characters and flashing Please check the loading circuit whether be right Tip Once the load abnormal is troubleshooting the screen will automatically back to first browsing page content e If the wind turbines in the brake protection status the screen display The screen display Brake characters and flashing This is the normal brake protection action for wind turbine Tip Once the wind turbine brake action is stop the screen will automatically back to first browsing page content Page 13 Specification of excellent controller 11 System setting Instructions ENTER key symbolizes set or confirm press this key to access setting window In setting window press this key to choice each parameter and go to next page Esc key cancel or manual switch In setting window press this key to return to browsing window and do not save the modified parameters 11 1 Press ENTER to access following content of screen firstly Vis SRV V1 Battery over discharge voltage Woe SN V2 Battery over discharge recovery voltage Press A key or V key to adjust the value each press means increase or reduce 0 1V 11 2 Press ENTER key to next page V3 Battery over charge voltage V4 Battery over charge recovery voltage