Home
CS+ V3.00.00 Integrated Development Environment User`s Manual
Contents
1. Explanation This message only appears during debugging Data was modified W1811330 Message The area where CPU access is needed was accessed while the program is run ning Explanation This message only appears during debugging The debugger is not allowed to read data from the CPU access area while the user program is running W1811333 Message The writing data for OFS1 register was modified to disable the voltage monitoring reset after a reset Explanation Ensure that the voltage monitoring reset is disabled after a reset LVDAS bit 1 W1811334 Message There s no data for option setting memory Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify the values to be set for the option setting memory in the file for download ing ztENESAS Page 147 of 152 CS V3 00 00 5 MESSAGES W1811336 Message Warning The download data were not written in the Trusted Memory area Explanation The area for the downloading of data includes locations in the trusted memory area Action by User Ensure that the area for the downloading of data does not include any locations in the trusted memory area W1811337 Message Warning The wait setting for the RAM was changed temporarily to access it cor rectly Explanation The memory wait cycle setting is incorrect
2. Specify a project file which can be handled by this product to open ztENESAS Page 25 of 152 CS V3 00 00 E0202006 Message 5 MESSAGES This is not a convertible project file Explanation This error occurs when attempting to open a file other than a project file that this product can handle Action by User Specify a project file which can be handled by this product to open E0202007 Message The project information cannot be restored Explanation This error occurs when the program fails to restore or convert project information It will also occur if the program fails to extract the structure of a project to copy Action by User Specify a project file which can be handled by this product to open E0202008 Message This is not a valid project file Explanation This error occurs when the program fails to restore project information Action by User Specify a project file which can be handled by this product to open E0202009 Message The specified item could not be removed from the project Explanation This error occurs when a deletion operation fails Action by User This item cannot be removed E0202010 Message Subproject addition failed Explanation This error occurs when an add operation fails Action by User Make sure that the file exists and is not corrupt E 0202011 Me
3. Action by User Yes Disconnect the pin connected to the external periphery and change the settings No Return to the original status without changing the settings R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 124 of 152 CS V3 00 00 Q0300009 Message 5 MESSAGES One or more pins are used in other macro Do you want to change all settings Action by User Yes Change the settings of all pins including those otherwise in use No Return to the original status without changing the settings Q0404000 Message xxx has been changed Save Q0615000 Message Also disable Access by stopping execution property of the debug tool Q0615001 Message Also enable Access by stopping execution property of the debug tool Q0615002 Message Also change Usage RAM monitoring and DMM by a debugging DTC system prop erty of the debugtool Q0801001 Message The file already exists Overwrite Action by User Yes Overwrite the file No Return the focus to the original dialog box without overwriting the file Q0810001 Message Discard analysis data and close the xxx panel of Program Analyzer to increase available memory Explanation When the application runs out of memory during analysis this appears to confirm whether to discard analysis results Action by User Yes This discards the analysis
4. E1208201 Message Device file is damaged or error is in file E1208203 Message Can not copy E1208204 Message Not enough memory E1208207 Message The specified name exceeds 15 characters E1208447 Message Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1208738 Message Illegal condition E1212288 Message No mapped address was accessed E1212289 Message Memory has different value E1212290 Message Illegal start address E1212291 Message Illegal end address E1212292 Message Illegal start address and end address E1212293 Message Illegal condition E1212294 Message User program is running
5. E1710063 Message The error occurred by the open break reference direct cause error message E1710064 Message The timer function is not supported in this debugger E1710065 Message The timer function is not supported in this environment E1710066 Message The error occurred by referring to the timer function direct cause error message E1710067 Message The trace function is not supported in this debugger E1710068 Message The trace function is not supported in this environment E1710069 Message The error occurred by referring to the trace facility direct cause error message E1710070 Message The error occurred by setting the coverage function direct cause error message E1710071 Message The error occurred by setting the function function direct cause error message E1710072 Message The error occurred by setting the open break function direct cause error message E1710073 Message The error occurred by setting the timer function direct cause error message E1710074 Message The error occurred by setting the trace function direct cause E1710075 Message The specified option is illegal E1710076 Message The input value is illegal Please input either a character string or a numerical value E1710077 Message Failed to obtain the download information
6. E1830001 Message The simulator version may be older to use the debugger Action by User Check that the simulator version is the latest E1830107 Message Memory allocation failed E1830108 Message An error has occurred during a memory access E1830200 Message The number of events has exceeded the maximum value E1830201 Message The specified event is not set E1830202 Message The specified pass count is outside the supported range E1830203 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 The specified data is outside the selected access size ztENESAS Page 95 of 152 CS V3 00 00 E1830204 Message 5 MESSAGES The specified data range is not correct The compare data1 should be smaller than the compare data2 E1830205 Message The specified interrupt vector is outside the supported range E1830206 Message The specified interrupt priority level is outside the supported range E1830700 Message Tracing is in progress E1830701 Message There is no trace data E1830702 Message There is no trace data of the specified frame E1830800 Message This function cannot be used during time measurement Action by User Only use this function while timer measurement is halted E1830801 Message Specified channel number is out of range Action
7. E0613010 Message Two or more events cannot be set to one timer event E0613012 Message Because the event of the same name already exists the event can t be made E0613013 Message A software break has already been set to the address except Simulator E0613014 Message Enable this event E0613015 Message Two or more events cannot be set to one trace event RL78 MINICUBE2 E0613016 Message An event can t be set as a variable beyond xxx bytes of size Action by User For example if an event is to happen in the value of a four byte variable set the event as two points by dividing the variable into the two lower and two higher order bytes In the case of a more detailed event change the setting by specifying the address range and not specifying a range of data E0615000 Message This is not a importable watch data file R20UT3099EJ0100 Rev 1 00 ztENESAS Page 49 of 152 Aug 01 2014 CS V3 00 00 E0800001 Message 5 MESSAGES Analysis aborted because memory is low Explanation This appears when an out of memory exception is detected during analysis Action by User Restart CS close all other panels and open the panel in which you wish to view analysis results E0801003 Message Could not find the file Explanation This appears when the specified file was not found Action by User Make sure that the file exists
8. E1203243 Message The type of the FPGA IFPGA in the main emulator unit is incorrect Update it with the programming tool E1203244 Message The version of the FPGA IFPGA in the main emulator unit did not match Update it with the programming tool E1203246 Message The combination of the target MCU and emulator pod is incorrect Update it with the programming tool E1203247 Message Trace block can not be stepped over E1203251 Message The version of the FPGA TFPGA in the emulator pod did not match Update it with the programming tool E1203253 Message Target is not connected E1203254 Message Failed in connect by LPD Please check the LPD connection settings E1203255 Message Can not find ENV file Explanation Opening the ENV file RH850Emulator env that is used for managing the combi nations of RH850 emulator products was not possible E1203256 Message Failed in reading ENV file Explanation The format of the ENV file RH850Emulator env that is used for managing the combinations of RH850 emulator products is incorrect E1203257 Message The emulator connected is over the number of restriction 4 sets Explanation This message appears if the CS is connected to a debugger while five or more E1 or E20 emulators are connected to the host machine via USB Action by User Ensure that no more
9. Explanation The specified project is already open Action by User Specify a different project E0222010 Message The specified file is invalid Enter a divert project file Explanation The specified file is invalid Action by User Specify a different project E0222011 Message The file name including the path is too long Make it within xxx characters Explanation The path specified by the project name and location is too long Action by User Specify a different project name or location E0222012 Message The subproject name is invalid A subproject with the same name cannot be made in the location where the main project exists Explanation There is already a main project with the same name excluding extension in the specified location Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a different project name or location ztENESAS Page 41 of 152 CS V3 00 00 5 MESSAGES E0222013 Message Any microcontroller type can be created doesn t exist Check the installation Explanation Microcontroller not found Action by User Make sure that the product is correctly installed E0222014 Message Failed to copy some files See the All Messages tab in the Output panel Explanation This indicates that there was a file copy error when
10. Explanation This error occurs when the open action fails for some reason Action by User Check the path to Explorer E0200004 Message Could not open a file with the specified application Explanation This appears when an application file specified in the project tree could not be opened Action by User Make sure that an executable application was specified E0200005 Message Clipboard setting failed Explanation This error occurs when data could not be set in the clipboard Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 There may not be enough memory ztENESAS Page 23 of 152 CS V3 00 00 E0200006 Message 5 MESSAGES Can not open the help Explanation When help is not opened it is displayed Action by User Please update this product Please contact your vendor or your Renesas Electronics overseas representative E0200007 Message The target item cannot be moved because it is not on the same row as the destina tion item Explanation This message appears when a sub item fails to be moved within the same hierar chy level of the tree E0200008 Message Failed to restart this product You may not have permission to restart Explanation This error occurs when failing in a restart of IDE Action by User Make sure you have access privileges to a restart of this produ
11. W0242002 Message The upper limit 64 of categories that can be registered to the Watch panel has been exceeded Explanation The maximum number of categories that can be registered in a single Watch panel is 64 Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Remove unnecessary categories or register it in a new Watch panel ztENESAS Page 134 of 152 CS V3 00 00 W0243001 Message 5 MESSAGES Cannot paste because the display format notation system bit width is different Explanation This message appears when pasting a memory value or ASCII characters in the Memory panel and the display formats of the string to paste and the Memory panel are different number base and bit width and the paste can therefore not be per formed Action by User In the Memory panel set the display format number base and bit width the same as the text to paste W0243002 Message Characters that cannot be pasted in the Memory Value Display area are included Explanation Illegal characters have been typed or pasted into the Memory panel s Memory Value Display area Action by User Specify a string that can be treated as a memory value W0243003 Message Only ASCII code can be pasted in the Character Display area Explanation On the Memory panel in the Character Display area text can only be pasted when the encoding is
12. Disconnect and close the window No Close the window without disconnecting Cancel Cancel closing the Main window ztENESAS Page 117 of 152 CS V3 00 00 Q0210002 Message 5 MESSAGES Also change the security ID of the debug tool Explanation In the Build Tool when the Security ID property is changed this message asks whether to also change the security ID of the debugging tool Action by User Yes Change the security ID of the debug tool No Cancel action Q0210004 Message Also change the programmable I O area start address of the debug tool Explanation In the Build Tool when the Programmable I O area start address property is changed this message asks whether to also change the Programmable I O area start address of the debugging tool Action by User OK Change the programmable I O area start address of the debug tool Cancel Cancel action Q0210005 Message Are you sure you want to clear all coverage information Explanation This appears when coverage information is cleared Action by User OK Clear all coverage information Cancel Cancel action Q0210006 Message Also change the endianness of the debug tool Explanation This appears when the endian property setting is changed in the build tool and the application asks whether you want to change the endian property setting als
13. E1812106 Message Coverage function is not available Action by User Check the connection between the emulator and the PC E1812500 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 PPC is used by the user program ztENESAS Page 92 of 152 CS V3 00 00 E1812501 Message 5 MESSAGES PPC1 is not enabled E1812502 Message PPC is working now E1812503 Message The specified function is not supported for this mcu E1812700 Message Can t invoke the Go with program break points because there s no events to use E1812701 Message The step command is not executable because the current address is in the Trusted Memory area Explanation You have attempted to start stepped execution from an address in the trusted memory area Stepped execution cannot be started from any addresses in the trusted memory area E1812800 Message An error has occurred in erasing of the external flash ROM The flash ROM may have been degraded E1812801 Message An error has occurred in programming of the external flash ROM The flash ROM may have been degraded E1812802 Message An error has occurred in verification of the external flash ROM The flash ROM may have been degraded E1812803 Message Failed to read data The external bus setting would be incorrect E1812804 Message Maker ID or device ID for the
14. E2201012 Message multiple module name or register name Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Some of the module names or register names in the device file are multiple ztENESAS Page 102 of 152 CS V3 00 00 5 3 Information Table 5 3 M0120001 Information Message 5 MESSAGES Installation is suspended because xxx is running It will be resumed next time you start the tool M0120002 Message You must restart your system for the updates to take effect M0120003 Message Installation is suspended because related updates are suspended It will be resumed next time you start the tool M0140033 Message All CS related tools were uninstalled so Integrated Uninstaller will be deleted Explanation All of the CS related tools that are displayed have been uninstalled by the inte grated uninstaller M0140044 Message The following product was also installed at the same time XXX Please install the latest service packs and security updates for this product using Windows Update and Microsoft Upadate Explanation This message appears when all installation of required environments has com pleted successfully without a reboot request and the window of the subsequently executed integrated installer has been closed M0190000 Message Failed to read license information The file is broken Please re enter licen
15. Writing xxx failed Explanation This error occurs when the program fails to write a file Action by User Check the access privileges to the file E0201008 Message Moving the file xxx to yyy failed Explanation This error occurs when the program fails to move a file Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Check the access privileges to the file ztENESAS Page 24 of 152 CS V3 00 00 E0201009 Message 5 MESSAGES Temporary file creation failed Explanation This message appears when a temporary file could not be created Action by User Check the access privileges to the file E0201010 Message Temporary file deletion failed Explanation This message appears when a temporary file could not be removed Action by User Check the access privileges to the file E0201011 Message Saving xxx failed Explanation Failed to save file Action by User Follow the instructions in the message to remedy the problem E0201012 Message Copy failed E0201013 Message Creating the file xxx failed Explanation This message appears when a file could not be created Action by User Check the access privileges to the file E0201015 Message Failed to apply save settings for the file xxx Explanation Failed to save file settings
16. An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0113015 Message A connection with the proxy server was denied Please contact your network administrator Action by User Make sure that you can display ordinary and secure Internet sites sites starting with https in Internet Explorer Contact your network administrator if you cannot E0113098 Message An internal error occurred in Update Manager Failed to download Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Please contact your vendor or your Renesas Electronics overseas representative ztENESAS Page 18 of 152 CS V3 00 00 E0113099 Message 5 MESSAGES An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0114000 Message A connection with the server has timed out Action by User Make sure that you can display ordinary and secure Internet sites sites starting with https in Internet Explorer Contact your network administrator if you cannot If you can the site may be blocked by a personal firewall or other security software Allow the Update Manager to conduct http and https communication The following executable file must be allowed lt
17. E1710029 Message Failed to read the coverage data direct cause E1710030 Message Failed to obtain the coverage data E1710031 Message XRunBreak can only be used in the simulator environment E1710032 Message The specified XRun Break option is illegal E1710033 Message The unit of the input break set time is illegal Please input the value within the range of 0 4 E1710034 Message Failed to set XRunBreak direct cause E1710035 Message Failed to refer XRunBreak direct cause E1710036 Message Sum of time tag can only be used in the simulator environment E1710037 Message Cannot use the sum of time tag option E1710038 Message The trace control mode can only be used in the simulator and IECUBE environ ment E1710039 Message Cannot use the trace control mode option E1710040 Message The trace complement can only be used in the IECUBE environment E1710041 Message Cannot used the trace complement option E1710042 Message The input option is illega Please input either Clear Addup Mode or Complement E1710043 Message The input option is illega Please input either Addup or Complement E1710044 Message The input trace mode is illega Please input either FullBreak FullStop or NonStop E1710045 Message Failed to obtain the trace data
18. Restart CS C1700003 Message Failed to execute the script file Action by User Restart CS C1700004 Message Failed to display the string direct error Action by User Restart CS C1710000 Message The specified name is illegal Action by User Restart CS If this does not resolve the problem reinstall CS C1710001 Message The specified name is already used Action by User Restart CS If this does not resolve the problem reinstall CS C1710002 Message Failed to read the necessary DLL Action by User Restart CS If this does not resolve the problem reinstall CS C1710003 Message Cannot fine the specified name Action by User Restart CS If this does not resolve the problem reinstall CS C1710004 Message Specified GUID is illegal Explanation This appears when the GUID for access is illegal Action by User Specify a correct GUID C1720000 Message Specified GUID is illegal Explanation This appears when access to a Bip execution instance fails C1720001 Message Specified name is illegal Explanation This appears when access to a Bip execution instance fails C1720100 Message Specified GUID is illegal Explanation This appears when access to a Pip execution instance fails C1720101 Message S
19. W0403016 Message Please firstly input valid xxx value W0403017 Message Please input or select a valid SFR address W0403018 Message When 20 MHz has been selected the circuit cannot be changed to a 1 MHz inter nal high speed oscillator W0403019 Message The following interrupt conflicts have been detected You must change the setting in that module before you can use it for other purpose W0403020 Message No channel can be used please modify anolog input pins selection W0403021 Message Xxx was changed the following macros should be updated yyy W0403022 Message Cannot reflect user option byte to Code generator Design Tool Please change the value of user option byte or set it at Code Generator Design Tool R20UT3099EJ0100 Rev 1 00 ztENESAS Page 141 of 152 Aug 01 2014 CS V3 00 00 5 MESSAGES W0403023 Message Cannot reflect build option to Code generator Design Tool Please change the set ting of build option or Code Generator Design Tool W0403028 Message The xxx function shared by the yyy pin can be only used in input mode using the port function in output mode is prohibited W0403029 Message Please select pin assignment setting W0403030 Message To use xxx module please release yyy module firstly W0403031 Message Please select the xxx W0403
20. Check that you have access rights for the files and folders Check that the files and folders exist E0223009 Message Failed to invoke the Windows Explorer menu for the specified file or folder Explanation This message appears when the Windows Explorer menu was not displayed in the Project Tree panel Action by User When multiple nodes have been selected check that all of them are files or fold ers in the same folder Check that you have access rights for the files and folders Check that the files and folders exist E0223010 Message Failed to change the microcontroller Explanation This message appears when changing the microcontroller in the Project Tree panel was not possible Action by User Check that the device file has been installed E0223011 Message There is no any selectable microcontroller Explanation This message appears in response to an attempt to change the microcontroller but there is no specifiable microcontroller in the target for the change Action by User Check that the device file has been installed E0223012 Message Can not change the extension of the editing file Explanation This message appears when an attempt is made to change the extension of the file being edited Action by User Close the editing file and change the extension of the file E0223013 Message Can not ch
21. Connect with a debugger ztENESAS Page 72 of 152 CS V3 00 00 E1710002 Message 5 MESSAGES Failed to start the debugger E1710003 Message Failed to stop the debugger E1710004 Message The input memory option is illegal Please input either Byte HalfWord or Word when you specify the access size Action by User Specify MemoryOption Byte MemoryOption HalfWord or MemoryOption Word E1710005 Message The input value is illegal Please input the value within the range of 0 4294967295 Action by User Specify the value within the range of 0 4294967295 E1710006 Message The input address is illega Please confirm the address Action by User Specify a correct address E1710007 Message It was not possible to write it at the specified address E1710008 Message Failed to read from the specified address E1710009 Message The specified option is illega Please input either Copy or Fill E1710010 Message Failed to copy E1710011 Message Failed to fill E1710012 Message The input option is illega Please input Coverage to specify UploadOption only E1710013 Message Failed to save the coverage data direct cause E1710014 Message The type of the input address is illega Please input either a numerical value or a character string Action by User Enter
22. E1212295 Message Verification error E1212296 Message No condition specified E1212297 Message Parameter size does not align with access size alignment E1212298 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specified address does not align with access size alignment ztENESAS Page 60 of 152 CS V3 00 00 E1212299 Message 5 MESSAGES Source address does not align with access size alignment E1212300 Message Destination address does not align with access size alignment E1212301 Message Illegal end address E1212302 Message Different access size in specified area E1212303 Message Different access size both in source and destination areas E1212304 Message Different access size in destination area E1212305 Message Different access size source and destination E1212306 Message Not enough memory E1212307 Message Failed in writing DMM E1212308 Message Overflowed mapping area E1212309 Message Processing was interrupted E1212310 Message This feature is not supported E1212543 Message Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Too
23. Q0293003 Message Are you sure you want to set the current compile options to the individual compile options for all build modes If No is selected copy the current build mode options only Explanation This message appears when individual compile options are specified Action by User Yes The individual compiler options are set for all build mode No Apply the current compile options to the individual compile options for the current build mode only Cancel Cancel action R20UT3099EJ0100 Rev 1 00 ztENESAS Page 121 of 152 Aug 01 2014 CS V3 00 00 Q0293004 Message 5 MESSAGES Are you sure you want to set the current assemble options to the individual assem ble options for all build modes If No is selected copy the current build mode options only Explanation This message appears when individual assemble options are specified Action by User Yes The individual compiler options are set for all build mode No Apply the current compile options to the individual compile options for the current build mode only Cancel Cancel action Q0293005 Message Are you sure you want to copy the current compile options to the assemble options for all build modes If No is selected copy the current build mode options only Explanation This message appears when the Build simultaneously property on the Common Options tabbed page is
24. Specify a correct break event type E1710118 Message Failed to disconnect the debugger direct cause E1710119 Message Failed to connect to the debugger direct cause E1710120 Message The specified register was not found Action by User Specify the existing register name E1710121 Message The specified debug tool is not supported Action by User Use a simulator or MINICUBE MINICUBE2 IECUBE E1710122 Message The input chip select is illegal Action by User Specify the value within the range of cs0 cs7 E1710123 Message Cannot change to the specified debug tool Action by User Specify the debug tool it s possible to change E1710124 Message Please connect to the debug tool before downloading Action by User Connect to the debug tool before downloading E1710125 Message Cannot set the specified map type E1710126 Message Please connect to the debug tool before executing the function Action by User Connect to the debug tool before executing E1710127 Message The specified function was not found Action by User Make sure that the function name exists and specify the existing function name E1710128 Message The coverage data can only be uploaded in the simulator environment Action by User Upload in the simulator environment
25. W0205021 Message The character string is too long Specify a character string with xxx or fewer charac ters Explanation This message appears when a string was specified in a string area that was longer than the maximum length Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a string of no more than the maximum number of characters ztENESAS Page 131 of 152 CS V3 00 00 W0205022 Message 5 MESSAGES The address expression is invalid Specify a symbol or numerical value Explanation This message appears when a string that is invalid as an address expression is entered in an area for specifying an address expression Action by User Specify a string that is correct as an address expression W0205023 Message The specified value is out of range Explanation This message appears when an out of bounds value is entered into a numeric input area in the properties or the like Action by User Enter a value within the correct range W0205024 Message The file name is invalid The characters lt gt cannot be used Explanation The string includes illegal characters Action by User Specify a valid file name W0205025 Message Xxx Cannot be specified Explanation This message appears when an input value in the properties could not be specified especially Action by
26. Wait for the information on the memory map to be acquired Action by User To cancel this processing press the ESC key or click on the Cancel button M0269002 Message Press ESC key to cancel processing Explanation Wait for the information on the memory map to be acquired M0291001 Message xxx was generated Explanation This message appears when iodefine h was successfully generated M0291002 Message The device was changed Update the header file by selecting Generate I O header file Explanation This message appears when CS detects a change of device at the time it opens a project M0291003 Message The device file was updated Update the header file by selecting Generate I O header file Explanation This message appears when CS detects a change of device file version at the time it opens a project M0291004 Message Due to the CS being old following build tools are disabled To use them update CS Explanation The core major version numbers of the files contained in build tools exceed the expected value and so are hidden when a project is opened Action by User Continue using the CS environment if this does not present a problem Alterna tively update your CS M0292001 Message Loading HEW project Explanation This message appears in the Progress Status dialog box while loadin
27. Anywhere in project or In specified folder M0209001 Message Could not execute step in for the following reason XXXXXXXXXXX Explanation This message appears when an exception occurred on execution of Step In from the menu Action by User For details refer to XXXXXXXXXXX M0209002 Message Could not execute step over for the following reason XXXXXXXXXXX Explanation This message appears when an exception occurred on execution of Step Over from the menu Action by User For details refer to XXXXXXXXXXX M0223001 Message Source files were added to the Project Tree panel but some files cannot be added to the project Explanation When a debug project is downloaded source files included in the load module are added automatically This appears when these files cannot be added because the maximum number of files that can be added to the project is exceeded Action by User Remove unneeded files M0229001 Message There are files not registered in the project See the All Messages tab in the Out put panel for details Explanation This message appears when an imported file in the Link Order dialog box includes the names of files that are not actually registered with the project Action by User Register the files with the project M0233001 Message Opens the Disassemble panel to show the current PC address b
28. CENESAS C A D TE Cp lt 3 z D CS V3 00 00 Integrated Development Environment User s Manual Message Target Device RL78 Family RX Family RH850 Family All information contained in these materials including products and product specifications represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp without notice Please review the latest information published by Renesas Electronics Corp through various means including the Renesas Electronics Corp website http www renesas com Renesas Electronics www renesas com Rev 1 00 2014 08 10 11 12 Notice Descriptions of circuits software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples You are fully responsible for the incorporation of these circuits software and information in the design of your equipment Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits software or information Renesas Electronics has used reasonable care in preparing the information included in this document but Renesas Electronics does not warrant that such information is error free Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information incl
29. Explanation This message appears when an exception is thrown while executing the step in menu command Action by User Make sure that the debugging tool is connected E0209005 Message Executing step over failed Explanation This message appears when an exception is thrown while executing the Step Over menu command Action by User Make sure that the debugging tool is connected E0209006 Message Return out failed Explanation This message appears when an exception is thrown while executing the Return Out menu command Action by User Make sure that the debugging tool is connected E0209007 Message Setting PC value failed Explanation This message appears when an exception is thrown while executing the Set PC Value menu command Action by User Make sure that the debugging tool is connected E0209008 Message Go to here failed Explanation This message appears when an exception is thrown while executing the Run to Here menu command Action by User Make sure that the debugging tool is connected E0209009 Message Restart failed Explanation This message appears when an exception is thrown while executing the Restart menu command Action by User Make sure that the debugging tool is connected E0209010 Message Return to here failed Action by User Make
30. Explanation This message appears when the debugger has failed to disable a timer event Action by User Solve the problem indicated as direct cause E1710165 Message Failed to delete the specified breakpoint direct cause Explanation This message appears when the debugger has failed to delete a timer event Action by User Solve the problem indicated as direct cause E1710166 Message Failed to enable the breakpoint direct cause Explanation This message appears when the debugger has failed to enable a breakpoint Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Solve the problem indicated as direct cause ztENESAS Page 80 of 152 CS V3 00 00 E1710167 Message 5 MESSAGES Failed to disable the breakpoint direct cause Explanation This message appears when the debugger has failed to disable a breakpoint Action by User Solve the problem indicated as direct cause E1710168 Message Failed to delete the trace event direct cause Explanation This message appears when the debugger has failed to delete a trace event Action by User Solve the problem indicated as direct cause E1710169 Message The specified trace event was not found Explanation This message appears when the specified trace event does not exist Action by User Specify the num
31. Failed to read install information Can not get the version of xxx for the following reason yyy Action by User Please contact your vendor or your Renesas Electronics overseas representative E0110011 Message Failed to read update condition The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0110012 Message Failed to read update condition The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0110013 Message Failed to read update condition The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111
32. Message Launching program program name failed Explanation Shown on failing to invoke a Windows program from the IDE Action by User Check that the program has been installed correctly E0292001 Message The workspace is invalid Explanation The workspace file is invalid Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a valid workspace file ztENESAS Page 45 of 152 CS V3 00 00 5 MESSAGES E0292002 Message The workspace contains no projects Explanation There are no projects in the workspace Action by User Specify a valid workspace file E0292003 Message Could not read HEW project Explanation An invalid project was specified Action by User Specify a valid project E0292004 Message Project file name is invalid Explanation The project file is invalid Action by User Specify a valid project file E0292005 Message The project uses an unsupported toolchain Explanation A project using an unsupported toolchain was specified Action by User Specify a valid workspace E0292006 Message File xxx already exists Explanation There is already a file with the same name as the converted project file Action by User Check the files in the folder Change the folder to convert E0292007 Message The project does not contain a de
33. and turn Owhole_program on No Ignore Owhole_program and restore the previous property settings ztENESAS Page 122 of 152 CS V3 00 00 5 MESSAGES Q0294003 Message Are you sure you want to set the current compile options to the individual compile options for all build modes If No is selected copy the current build mode options only Explanation This is to confirm the scope of individual compiler options when they are set Action by User Yes Execute the command No Set the current compiler options for the current build mode only Cancel Cancel the command Q0294004 Message Are you sure you want to set the current assemble options to the individual assem ble options for all build modes If No is selected copy the current build mode options only Explanation This is to confirm the scope of individual assembler options when they are set Action by User Yes Execute the command No Set the current assembler options for the current build mode only Cancel Cancel the command Q0294005 Message Are you sure you want to copy the current compile options to the assemble options for all build modes If No is selected copy the current build mode options only Explanation This is to confirm changing of the value of the compiler option Build simultane ously from Yes to No Action by User Yes Execute the command No Co
34. direct cause E1710078 Message Failed to obtain the download property E1710079 Message Failed to set the download property E1710080 Message Failed to generate the download information E1710081 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Failed to download direct cause ztENESAS Page 75 of 152 CS V3 00 00 5 MESSAGES E1710082 Message Failed to line assemble direct cause E1710083 Message Failed to disassemble direct cause E1710085 Message Failed to obtain the register value direct cause E1710086 Message Failed to set the register value direct cause E1710087 Message Failed to erase direct cause E1710088 Message The specified option is illegal E1710089 Message Could not find the specified variable E1710090 Message Failed to read the value of the variable direct cause E1710091 Message Failed to set the value of the variable direct cause E1710092 Message Failed to delete the XRunBreak direct cause E1710093 Message Failed to display the editor panel direct cause E1710094 Message Failed to display the disassembly panel direct cause E1710095 Message Failed to display the memory panel direct cause E1710096 Message The specified MemoryOption is not supported in this environment E1710097 Message Please specify Oxyyy
35. reinstall after deleting all files in the folder con taining file noted in the message E0100010 Message Failed to start xxx Failed to write yyy Action by User Reinstall CS If this does not resolve the problem reinstall after deleting all files in the folder con taining file noted in the message E0100014 Message Failed to write temporary file Explanation This appears when the user specified the pass which can t write a file in environ ment variable TEMP or when more than 65 535 temporary files exist in the folder Action by User Make sure that it is possible to write files in the folder specified by the environment variable TMP E0100019 Message Failed to read temporary file Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Temporary files created by the Update Manager may have been deleted or other wise manipulated by other than the Update Manager ztENESAS Page 13 of 152 CS V3 00 00 E0110004 Message 5 MESSAGES Failed to get update information The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0110010 Message
36. the full path to the tar get file is output to xxx Action by User Check that the file is not opened by another process CS or editor and is read able and writable E0202075 Message Failed to store settings to the file xxx The file can be opened by other process or you don t have a write permission Retry Check whether it can store settings again Cancel Do not store settings and continue exiting Explanation When storing information for each user in the PC has failed the full path to the tar get file is output to xxx Action by User Check that the file is not opened by another process CS or editor and is read able and writable E0202076 Message Failed to store settings to the file xxx The file can be opened by other process or you don t have a write permission Retry Check whether it can store settings again Cancel Do not store settings and continue processing Explanation When storing information for each user in the PC has failed the full path to the tar get file is output to xxx Action by User Check that the file is not opened by another process CS or editor and is read able and writable E0203001 Message An error occurred during build Explanation This appears when an error occurred during the build Action by User Follow the instructions in the message to remedy the problem E0203002 Me
37. update integrated development environment framework and a plug in W0202004 Message There is a plug in that doesn t correspond to the version of the specified compiler package See the All Messages tab in the Output panel Explanation Some or all plug ins no longer function because the compiler version has changed Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Make sure that the versions of the plug ins and compiler package are compatible ztENESAS Page 129 of 152 CS V3 00 00 W0202005 Message 5 MESSAGES Can not open the project with last saved status See the All Messages tab in the Output panel Explanation This appears when loading a project and the project could not be loaded with the last status saved W0205001 Message Fewer than xxx or more than yyy characters cannot be specified Explanation This message appears in the Message dialog box if a string is specified for the area that is shorter than xxx characters or longer than yyy characters when xxx and yyy are the minimum and maximum lengths respectively The values of xxx and yyy are dependent on the input area Action by User Specify a value that is in bounds W0205002 Message More than xxx characters cannot be specified Explanation This message appears when a line in the display source set in the Text Edit dialog box is longer than the maximum
38. xxxyyyzzz Explanation This message dialog box appears when an error occurred attempting to save the specified file Action by User Check that the file is writable If a shortage of memory is the reason for the failure close all panels except the tar get Editor panel and try to save the file again E2000004 Message Searching or replacing failed Explanation This message dialog box appears when an error occurred attempting to perform a find or replace operation E2000006 Message Cannot open file because this would exceed the maximum allowed memory usage Explanation This message dialog box appears when attempting to open an editor file which might results in an out of memory exception This might be due to a very large file being opened or by opening many files which cause the memory limit to be reached If there is another large file open close it and open the file again E2000007 Message Copy size is too large for the clipboard cannot complete request Explanation The clipboard has a memory limit based on the current OS state This message appears when attempting to copy data larger than the clipboard E2000008 Message Expression in Go To dialog is invalid Explanation The Go To dialog can only accept a line number or a Debugger expression that evaluates to an address E2000009 Message The maximum bookmarks limit 50 has b
39. 0 reset may cause a failure of the debugger Please confirm the data for OFS1 E1811329 Message It is unable to enable Startup Voltage Monitoring 1 Reset Action by User Specify a value that will disable Startup Voltage Monitoring 1 Reset E1811331 Message It is unable to write data to the work ram area for start stop function Action by User Change the address of the work RAM area E1811332 Message It is unable to enable the voltage monitoring 0 reset of OFS1 Action by User Check the setting of the OFS1 register E1811335 Message It is unable to write data to the Trusted Memory area Explanation You have attempted writing to the trusted memory area Action by User Avoid writing to the trusted memory area E1811401 Message The event channel for the sequential combination is not correct E1811402 Message The before PC break has overlapped with the PC event break E1811403 Message The PC event break has overlapped with the operand access event break E1811406 Message The performance counter is opened to user program and the emulator debugger can not modify the setting for performance E1811407 Message The same event has been specified for both the before PC event and the trace start event E1811408 Message The events used for AND Sequential combination can not be set to the ot
40. 0xzzz when you specify xxx in the memory option E1710098 Message Failed to obtaion the memory option E1710099 Message Failed to set the memory option E1710100 Message Failed to read the IE register E1710101 Message Please check the connection to the debugger E1710102 Message Failed to set the IE register E1710103 Message Failed to refer to the DCU register E1710104 Message Failed to set the DCU register E1710105 Message The specified MapType is illega E1710106 Message Please specify the chip select information E1710107 Message Failed to generate the mapping information direct cause E1710108 Message Failed to set the mapping information direct cause E1710109 Message Stack information cannot be trusted E1710111 Message Failed to delete the breakpoint direct cause R20UT3099EJ0100 Rev 1 00 tENESAS Page 76 of 152 Aug 01 2014 CS V3 00 00 E1710112 Message 5 MESSAGES The specified break event was not found Action by User Specify the existing break event number E1710113 Message Failed to enable the specified breakpoint direct cause E1710114 Message Failed to disable the specified breakpoint direct cause E1710115 Message Address condition is not set E1710116 Message Failed to set the breakpoint direct cause E1710117 Message The specified break event type is illegal direct cause Action by User
41. Check the access privileges to the file Make sure that the file is not corrupt E0820002 Message The input name can t release registration Action by User Make sure that the specified name is registered on the Analysis Chart panel E0820003 Message Failed to Register to Analysis Chart Explanation This message appears when the execution of the command registered in Analysis Chart failed for some reason Action by User Make sure that the number of variables registered in the Analysis Chart panel does not exceed the limit of 16 E0821001 Message No column to save a file Action by User Execute analysis and update the data Display the row you wish to save in the Select Field dialog box E0821002 Message No row to save a file Action by User Execute analysis and update the data Display the column you saved in the Folder Settings dialog box E0821003 Message Failed to save a file because the number of lines had exceeded the limitation value of Excel Action by User Set the column to display in the Folder Settings dialog box to no more than 65 535 E0821004 Message Jump to source failed Action by User Make sure that the file exists Check the access privileges to the file Make sure that the file is not corrupt Make sure that there is an associated application for opening the file E0821005 Messa
42. E1710129 Message Cannot upload the coverage data Action by User Upload a coverage on the platform which is being supported E1710130 Message The recycling setting of the coverage data is set to No Action by User Set to Yes the recycling setting of the coverage data before uploading E1710131 Message Please connect to the debugtool before debugging Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Connect to the debug tool before continuation executing ztENESAS Page 77 of 152 CS V3 00 00 E1710132 Message 5 MESSAGES The platform is not supported E1710133 Message Acquisition of break factor went wrong direct cause E1710134 Message The specified parameter is illegal Explanation This message is shown when None is set in the parameter or the parameter is not specified E1710135 Message ReuseCoverageData setting function cannot be used Explanation This appears when you try to configure reuse of coverage data when the platform or debugging tool does not support this setting Action by User Use a platform or debugging tool that supports this setting E1710136 Message Cannot use IE Register in this Debugging Tool Explanation This appears when the selected debugging tool does not support the IE register Action by User Use a debugging tool that supports
43. Message Check sum error E1249171 Message Too wide address range to upload gt 1M byte E1249172 Message Failed in writing file E1249173 Message Illegal program number E1249174 Message Load information is full E1249176 Message Specified file is not load module E1249177 Message Failed in writing memory E1249179 Message Programmable IOR address not specified E1249182 Message Flash erase is not supported E1249183 Message This feature is not supported E1249185 Message The debugger can t download at high speed because the object file has the code out of the internal ROM and the internal RAM E1249186 Message Please specify the start address and area by 4 bytes boundary E1253248 Message Error occurred inside debugger E1253249 Message Not enough memory E1253250 Message Failed in reading initialization file expc ini E1253251 Message Emulator is not connected E1253252 Message Can not find Dynamic Link Library E1257344 Message Illegal argument E1257345 Message Illegal start address E1257346 Message Illegal end address E1257347 Message Too large size E1257348 Message Can not open file E1257349 Message Failed in reading file E1257350 Message
44. Message Failed to stop tracing E1811914 Message This feature is not supported for the current trace mode E1811915 Message The trace facility doesn t work E1811916 Message Trace function is not available Action by User The trace facility is not available when the coverage measurement facility is in use E1812100 Message Address areas allocated for the coverage memory are overlapped Action by User Specify coverage measurement areas so that they do not overlap each other E1812101 Message The coverage block to which an address area has been assigned is disabled Action by User Check the coverage measurement areas E1812102 Message No coverage data found Action by User Check the coverage measurement areas E1812103 Message Warning Some coverage data may have been lost Action by User Data loss occurred and there may be a lack of data in coverage measurement results E1812104 Message Warning Coverage measurement failure may have occurred because of the reset operation Action by User There may be a lack of data in coverage measurement results before and after a reset E1812105 Message Warning Both coverage measurement failure caused by the reset operation and data lost may have occurred Action by User There may be a lack of data in coverage measurement results
45. Message A serial communication error Receiving timeout error E1813509 Message A serial communication error Releasing reset timeout error E1813512 Message A serial communication error Send timeout error E1813600 Message Failed to communicate with the mcu because its source clock of serial communica tion is changed Please retry with the baud rate reduced E1813700 Message The firmware area has been damaged Please try to re connect the debugger E1814000 Message A timeout error The power supply to the MCU is off E1814001 Message A timeout error The MCU is in the reset state E1814003 Message A timeout error The internal clock is halted because the MCU is in the standby mode E1814004 Message A timeout error The internal clock is halted because the MCU is in the sleep mode E1814016 Message A timeout error MCU transitioned to sleep mode E1814017 Message ID code authentification is now invalid E1814300 Message A timeout error The emulator does not connected with the target system E1814301 Message A timeout error The command is not executable because the MCU power supply in the target system is turned off E1814302 Message A timeout error The command is not executable because the signal on the RESET pin is active E1814600 Message Failed to start up with the hot plug in The specified endian does not match the cur rent endian E1814601
46. No Cancel action Q0202002 Message Could not find the project file Unregist the corresponding project from the list of favorite project Explanation This appears when selecting a project from favorites and the project file does not exist Action by User Yes Delete project No Do nothing Q0202003 Message Are you sure you want to import build options Current whole build options and build modes are replaced by specified project val ues Explanation This appears when selecting the Import Build Options menu Action by User Yes The import of the build options begins No Cancel action Q0202004 Message Xxx is not a project for the yyy Do you want to reopen this project by the proper CS and close this product If No is selected restore only file structure on this product and you can not build and debug the project Explanation This appears when attempting to load a project from another package Q0202005 Message Xxx is not a project for the yyy Are you sure you want to just open the project If you just open the project only file structure will be restored and you will not be able to build and debug the project If you would like to build and debug open the project by the proper CS Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when attempting to load a project from anothe
47. Reading of file went wrong E1257351 Message Failed in writing file E1257352 Message Not enough memory E1257353 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Illegal file format ztENESAS Page 68 of 152 CS V3 00 00 5 MESSAGES E1257354 Message Verification error E1257360 Message This feature is not supported E1257361 Message Load it outside the mapping area E1265535 Message Interrupted E1310000 Message Can t allocatemomory Explanation Could not obtain memory required for processing Action by User Close other applications or increase Windows virtual memory then acquire the memory E1310001 Message Can t open file Explanation Could not open the specified file Action by User Make sure that the file exists and check its attributes E1310002 Message Illegal file format Explanation The format of the specified file is invalid Action by User Make sure that the attributes of the specified file Open File dialog box are correct and check the contents of the file E1310003 Message Can t write file Explanation Could not write to the specified file Action by User Make sure that the file exists check its attributes and make sure that there is enough disk space E1310180 Message Ausermodel file is not specified Explanation No user model file was speci
48. Time per grid Time Div property Value per grid Val Div 7 16 property Offset 1 16 property Action by User Check the Auto adjustment property setting M0825001 Message The synchronization function was turned off Explanation Set the filtering conditions in the Filter Settings dialog box then click OK At this time if the Linking with the Project Tree panel button Linking with the Editor panel button or Linking with the Debug Manager panel button is enabled in the toolbar of the Function List Variable List panel it is disabled automatically M0825002 Message The condition of filter settings of current panel was cleared Explanation Enable the Linking with the Project Tree panel Linking with the Editor panel Linking with the Debug Manager panel button in the toolbar of the Function List Variable List panel At this time if filtering conditions have been set in the Filter Settings dialog box then they are cleared automatically M0826001 Message Saving a call graph image Action by User Press the Cancel button to abort M0827001 Message Finished to the search Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when a search was started from the target function starting point one or more functions meeting the search conditions were found and the search has reached the function before the first tar
49. User Specify the different value within the correct range W0205026 Message Can not specify the odd address Explanation This message appears when the value entered in the field for a property is odd but an even value is required Action by User Specify an even value W0205027 Message Names that begin with a number can not be specified Explanation This message appears when no names that begin with numbers are allowed Action by User Specify a name that does not begin with a number W0205028 Message Can not specify a reserved word xxx Explanation This message appears when the specified value is invalid as a reserved word xxx indicates a list of reserved words Action by User Specify a value that is not a reserved word W0208001 Message Break could not be set Specify a global variable Explanation Failed to set a breakpoint that is triggered when a global variable is read written or read written Action by User Specify a global variable in the Editor panel or Watch panel W0208002 Message Setting for recording to trace could not be done Specify a global variable Explanation Failed to set a trace that logs when a global variable is read written or read writ ten Action by User Specify a global variable in the Editor panel or Watch panel W0208003 Message Setting for
50. a figure or a character string to the address E1710015 Message Failed to identify the address Please confirm the address E1710016 Message The input address value is illega Please input the value within the range of 0 4294967295 E1710017 Message The file already exists Explanation This message is shown when the overwrite option is not specified and a file exists at an upload destination Action by User Specify the overwrite option or change the upload destination or delete a file in an upload destination E1710018 Message The specified upload option is illegal E1710019 Message Failed in upload direct cause E1710020 Message Failed to upload direct cause E1710021 Message The specified RunOption is illegal E1710022 Message Failed to step in step over direct cause E1710023 Message The specifed StepOption is illegal E1710024 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Failed to stop the debugging tool direct cause 2tENESAS Page 73 of 152 CS V3 00 00 E1710025 Message 5 MESSAGES Failed to display the stack trace direct cause E1710026 Message Failed to obtain the PC value direct cause E1710027 Message Failed to clear the coverage data direct cause E1710028 Message The function name must be specified
51. are not subject to radiation resistance design Please be sure to implement safety measures to guard them against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesas Electronics product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other appropriate measures Because the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or systems manufactured by you Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances including without limitation the EU RoHS Directive Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture use or sale is prohibited under any applicable domestic or foreign laws or regulations You should not use Renesas Electronics products or technology described in this document for any purpose relating to military applic
52. by User Yes Continue the processing No Cancel action Q0204002 Message Load module file xxx has changed Do you want to download it again Explanation This appears when Observe downloaded load module files changing is enabled and the load module file is modified Action by User Yes The download is executed No Cancel action Q0206001 Message No data corresponding to the search conditions was found Search from xxx of the specified range Explanation This appears in the Message dialog box when no results were found for the search parameters in the Memory Search or Trace Search dialog box xxx will be either start or end Action by User Yes Close the Message dialog box and perform the search again from the beginning of the range No Close the Message dialog box and move the focus to the original dialog box Q0210001 Message End debugging by disconnecting from the debug tool Explanation When closing the Main window while connected to the debugging tool a confir mation Message dialog box appears asking the user whether to disconnect the debugging tool This message appears when closing a project while connected to the debugging tool This message appears when opening a project or making it newly while con nected to the debugging tool Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Yes
53. changed from Yes to No Action by User Yes The compiler options are copied to all build mode No Copy the current compile options to the assemble options for the current build mode only Cancel Cancel action Q0293006 Message Are you sure you want to set the current compile options to the individual assemble options for all build modes If No is selected copy the current build mode options only Explanation This message appears when individual assemble options are specified with simultaneous build enabled Action by User Yes The compiler options are copied to all build mode No Copy the current compile options to the assemble options for the current build mode only Cancel Cancel action Q0294001 Message You are setting the Level3 Inter module optimization The individual compiler assembler option becomes invalid by level 3 The object library file s you registered also becomes invalid once And the libraries added in the Using libraries property are removed See the AIl Messages tab in the Output panel Continue the setting Explanation This is to confirm if you really wish to set the inter module optimization Owhole_program option as a build property of the CC RL compiler Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Yes Turn the individual options off exclude obj lib files added by the user
54. cloning copying a project Action by User Check the files making up the project to be copied E0222015 Message Overwriting project file failed The project file may be read only Explanation This appears when the application fails to create a project file by overwriting an existing one Action by User Specify a different project file name to create E0223001 Message The specified file could not be opened Explanation This error occurs when the Project Tree panel fails to open the file Action by User Make sure that the file exists and is not corrupt Check the access privileges to the file E0223002 Message Deleting xxx failed Explanation This message appears when the program fails to delete a file or other object Action by User Make sure you have access privileges to the file before deleting it E0223003 Message The specified file xxx could not be opened Explanation This error occurs when the Editor panel fails to open the file Action by User Make sure that the file exists and is not corrupt Check the access privileges to the file Make sure that the file format is supported E0223004 Message Detecting character code failed Explanation This error occurs when the Editor panel fails to detect the file s character encoding Action by User Make sure that the file is not corrupt Make sure that the file format is supported E0223005 Message No additional characters can be entered Explanation This err
55. condition can be set only for the 1st order E1891334 Message PC event is full E1891335 Message The event with pass count can not be set as the reset event E1891336 Message The address range condition can be set only for the one event E1891337 Message Both the event with address range condition and the data access event at the 1st order of the sequential condition have been specified These conditions can not be set at the same time E1891338 Message Data access event is full E1891355 Message Registered event count exceeds its limit of the combination condition E1891356 Message The function is not selectable because the RAM function is enabled E1891358 Message Data Access event can not be set as the reset event E1891359 Message Data Access events can be used up to 2nd order E1891360 Message A PC break has already been set to the address E1891361 Message The PC break cannot be added any further E1891363 Message Specified event id has already been used E1891364 Message Specified address condition is incorrect E1891365 Message Specified access attribute is incorrect E1891366 Message Specified access size is incorrect E1891367 Message Specified channel is incorrect E1891368 Message Specified measurement item is incorrect
56. condition is not set Explanation This message appears when address or variable expression condition was not specified Action by User Set address or variable expression condition E1710193 Message Failed to set the access by stopping execution direct cause Explanation This message appears when the debugger has failed to set the access by stopping execution Action by User Take appropriate measures in response to direct cause E1710194 Message Failed to get the access by stopping execution direct cause Explanation This message appears when the debugger has failed to get the access by stopping execution Action by User Take appropriate measures in response to direct cause E1710195 Message Failed to set the operation after trace memory is full direct cause Explanation This message appears when the debugger has failed to set the operation after trace memory is full Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Take appropriate measures in response to direct cause ztENESAS Page 83 of 152 CS V3 00 00 E1710196 Message 5 MESSAGES Failed to get the operation after trace memory is full direct cause Explanation This message appears when the debugger has failed to get the operation after trace memory is full Action by User Take appropriate measures in respo
57. condition is one Explanation This message appears to the right of the Condition 1 combo box when it is blank and the Condition 2 combo box is not Action by User Enter a value in the Condition 1 combo box E0290001 Message This section information file hsi cannot be read Explanation This message appears when format of the specified section information file is invalid or not supported E0291001 Message Can not specify this option Explanation This message appears when an invalid option has been selected E0291002 Message The selected type of output file cannot be used by the application project Explanation This message appears when an invalid option has been selected E0291003 Message The selected type of output file cannot be used by the library project Explanation This message appears when an invalid option has been selected E0291004 Message The project excludes the file which cannot be specified as an excluded file File name xxx Explanation This appears when changing the HEW project as which exclusion set the file which can t be established cfg file E0291005 Message Failed to back up the xxx file Generating the I O header file is aborted Explanation This message appears in case of failure to delete an existing bak file or to rename iodefine h as iodefine bak E0291006
58. designated Explanation This appears when the device file could not be specified by the df option E2200004 Message critical error occurred Explanation This appears when an unexpected exception occurred The stack trace for the exception that occurred immediately before the unexpected exception is output E2200011 Message cannot output header file Explanation This appears when writing to the I O header file failed Action by User Check that the specified path exists and the file is writable E2201001 Message cannot read device file unknown file Explanation The specified file is not a device file so reading it as one was not possible E2201002 Message cannot read device file unknown format version Explanation The device file was for a non supported format version so reading it as one was not possible E2201003 Message cannot read device file unknown series Explanation The device file was for a non supported device so reading it as one was not possi ble E2201004 Message cannot read device file unknown series version Explanation The device file was for a non supported device version so reading it as one was not possible E2201011 Message illegal module name or register name Explanation Some of the module names or register names in the device file are incorrect
59. does not exist W0261003 Message The section name is invalid The characters 0 9 A Z a z _ can be used only Explanation This appears when a section name is specified in the Link Directive File Genera tion dialog box using illegal characters Action by User Specify the section name using valid characters W0261004 Message A section with the same name already exists Explanation This appears when an existing section name is specified in the Link Directive File Generation dialog box Action by User Change the name of the section to one that does not exist R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 136 of 152 CS V3 00 00 W0261005 Message 5 MESSAGES The symbol name is invalid The characters 0 9 A Z a z _ can be used only Explanation This appears when a symbol name is specified in the Link Directive File Genera tion dialog box using illegal characters Action by User Specify the symbol name using valid characters W0261006 Message A symbol with the same name already exists Explanation This appears when an existing symbol name is specified in the Link Directive File Generation dialog box Action by User Change the name of the symbol to one that does not exist W0261007 Message The section name is invalid Specified name is a reserved section name for particu lar segment use only Explan
60. file E0210005 Message Failed to reuse the last result of coverage Retry Retry reusing Cancel Keep connection processing Explanation This appears upon failure to load the coverage results Action by User Check the access privileges to the file E0210006 Message Disconnecting from a debug tool because the connection has timed out Explanation This message appears when communication with the debugging tool times out Action by User 1 Check the emulator power 2 Check whether the USB cable isn t cut E0210007 Message Failed to set data to a debug tool Explanation This appears upon failure to set of data to a debug tool Action by User 1 Follow the instructions in the message to remedy the problem 2 Check the emulator power 3 Check whether the USB cable isn t cut E0210008 Message Hot Plug in is failed Explanation This message appears when a hot plug in fails Action by User 1 Check the emulator power 2 Check whether the USB cable isn t cut E0210009 Message Failed to download Explanation This appears when a download has failed Action by User 1 Check the emulator power Check whether the USB cable isn t cut Make sure that there are no problems with the file to download R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 38 of 152 CS V3 0
61. information E0208011 Message Event could not be removed Explanation This error occurs from the Event Setup menu This error occurs when there is no symbol information E0208012 Message Event could not be enabled Explanation This error occurs from the Event Setup menu This error occurs when there is no symbol information E0208013 Message Up to xxx action events can be set Explanation You can register up to the number of action events shown Action by User Delete unneeded action events E0209001 Message Resetting program failed Explanation This message appears when an exception is thrown while executing the Reset menuu command Action by User Make sure that the debugging tool is connected E0209002 Message Executing program failed Explanation This message appears when an exception is thrown while executing the Run menu command Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Make sure that the debugging tool is connected ztENESAS Page 36 of 152 CS V3 00 00 E0209003 Message 5 MESSAGES Stopping program failed Explanation This message appears when an exception is thrown while executing the Stop menu command Action by User Make sure that the debugging tool is connected E0209004 Message Executing step in failed
62. information Numeric representation Decimal XXXX Hexadecimal OxXXXXX All trademarks or registered trademarks in this document are the property of their respective owners TABLE OF CONTENTS 1 GENERALS sin propel oped ate oh bite hat hae hole la eta Die COME ASF hice eeu WEY GSA a te ie 8 5 2 MESSA CGE FORMA TT Srgiccica Sees ete asa arate ek Bak ae a Weer etek a teG asec dh a E 6 3 MESSAGE TYPE S E AE eta watt Bee a N A eatin das BEE 7 4 COMPONENT NUMBERS 0000000 ccc eee eee eee ees 8 5 MESSAGES dann ea a E e ENE cata tr E aE EE e a a e TT LE E a ee 9 5 1 l ternal Errors onerare er e a A N T A T A tae ar Wace E AU a 10 5 2 Faal E OS oe oo is oe Sa A ee cea E ec 12 5 3 AOTAN AEE E ak pen eo no caval a nese Bs ee E TETN A duo ob E Ge Ok en EE TT 103 5 4 Choice Siman teera aes Ate Sit fe hes Dee acacia ds laerarce tober a det keaton Dh ake pe butik agate Pao aa heaters the 112 5 5 Warning Sapne samipi a de ne Bee oe eRe eda pase oR eA eet Qe ur a Rae cae webs 128 Revision Record rene deee ee ee ee ee be ee eee 149 CS V3 00 00 1 GENERAL 1 GENERAL This document describes internal error message fatal error message information message choice message and warn ing message that CS outputs The message is output to Output panel or Message dialog box etc R20UT3099EJ0100 Rev 1 00 ztENESAS Page 5 of 152 Aug 01 2014 CS V3 00 00 2 MESSAGE FORMATS 2 MESSAGE FORMATS This chapter describes
63. installations were suspended Do you want to resume installation Q0120005 Message There are suspended installations Close the following applications before resum ing the installations The application may display the icon in the notification area system tray XXX Q0120006 Message Administrative privileges is required to run the updates Do you want to acquire administrative privileges to continue updates If you select Yes the dialogue for acquire the administrative privileges will be displayed Q0130001 Message Do you want to delete files corresponding to the selected updates Q0140006 Message Multiple information files used to update and obtain information about the software were found on your computer Do you want to replace these files with the information file that is included in the product being installed Select Yes to replace the files and continue the installation Select No to cancel the installation now Q0140007 Message A different version of the information file used to update and obtain information about the software was found on your computer Do you want to replace the file with the information file that is included in the prod uct being installed Select Yes to replace the file and continue the installation Select No to keep the original file and continue the installation Q0140011 Message Are you sure you want to cancel the installation Explanation Thi
64. is not regis tered W0140018 Message Installation succeeded To complete the installation please reboot your computer Explanation This appears when the entire installation was successful and a restart is neces sary W0140022 Message The installation was interrupted before it finished Explanation This appears when the installation is aborted before completion W0140025 Message The installation was aborted before finish Please reboot your computer Explanation This appears when the installation was aborted and the installation of the com pleted portion before cancelling requires a restart W0140031 Message To complete the uninstallation it is necessary to reboot your computer W0140042 Message The following products are required to reboot Windows to complete the installation Please reboot your computer XXX Please install the latest service packs and security updates for this product using Windows Update and Microsoft Upadate Stop the installation Explanation This message appears when all installation of required environments has suc ceeded and a reboot is required for all of them W0140043 Message The following products are required to reboot Windows to complete the installation Please reboot your computer XXX The following product succeeded in installation XXX Please install the latest service packs
65. it E1710137 Message Acquisition of cpu status went wrong direct cause Explanation This appears upon failure to obtain the CPU status E1710138 Message Acquisition of ie status went wrong direct cause Explanation This appears upon failure to obtain the IE status E1710139 Message The specified address is straddling boundary of endian Explanation This appears when the specification spans an endian boundary Action by User Revise your address specification E1710140 Message Function is not supported Explanation This appears when a command to get or set ProcessorElement is called in a proj ect for a product that does not support multicore Action by User Do not use this with products that do not support multicore E1710141 Message It is not connected with a debugger In changing please connect with a debugger Explanation This appears when a command is called to change the processor number when the debugger is not connected Action by User Connect the debugger E1710142 Message Processor element used now is the same as specified processor element Explanation This appears when the specified processor number is the same as the one cur rently in use Action by User Specify a processor number that is different from the one currently in use E1710143 Message Ac
66. lt gt Explanation This appears when an illegal character is used in the build mode name Action by User Modify the build mode name so that it does not include an illegal character E1720027 Message Failed to get the section start address direct cause Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when the current linker does not support setting of the section start address ztENESAS Page 85 of 152 CS V3 00 00 E1720028 Message 5 MESSAGES Failed to set the section start address direct cause Explanation This appears when the current linker does not support setting of the section start address or when an illegal value is specified Action by User Correct the setting when it is illegal E1720029 Message Failed to get the alignment of the section direct cause Explanation This appears when the current linker does not support section alignment E1720030 Message Failed to set the alignment of the section direct cause Explanation This appears when the current linker does not support section alignment or when an illegal value is specified Action by User Correct the setting when it is illegal E1720031 Message Failed to get the ROM to RAM mapped section direct cause Explanation This appears when the current linker does not support section mapping from
67. may be invalid Make sure that the debugging tool is connected ztENESAS Page 35 of 152 CS V3 00 00 E0208003 Message 5 MESSAGES The file xxx was modified after it was downloaded The settings which depends on line number such as the event setting and PC position changes cannot be done from this panel Explanation This error occurs when a file was modified after downloading Action by User Download a new built module E0208004 Message Setting action event failed E0208005 Message Trace event could not be set Explanation This error occurs when a trace event could not be set on the Editor or Disassemble panel Action by User The setting may be invalid Make sure that the debugging tool is connected E0208006 Message Timer event could not be set Explanation This error occurs when a timer event could not be set on the Editor or Disassemble panel Action by User The setting may be invalid Make sure that the debugging tool is connected E0208009 Message An event could not be set to the specified location Explanation This error occurs from the Event Setup menu Action by User This error occurs when there is no symbol information E0208010 Message Event could not be disabled Explanation This error occurs from the Event Setup menu This error occurs when there is no symbol
68. number of characters Action by User Shorten the line that is greater than the maximum length so that it is within the maximum number of characters W0205003 Message More than xxx lines cannot be specified Explanation This message appears when the display source set in the Text Edit dialog box is longer than the maximum number of lines Action by User Make sure that the number of lines is no more than the maximum limit W0205004 Message Specify xxx digits in hexadecimal Explanation This message appears when the string contains characters that cannot be used to represent a base 16 number including when the number of digits is valid Action by User Specify a hexadecimal number with effective number of digits W0205006 Message Specify a numerical value Explanation A number specifying an area includes non numeric characters Action by User Specify numeric characters W0205007 Message Specify in decimal Explanation A decimal number specifying an area includes characters that cannot be used to represent a decimal number Action by User Specify numeric characters as base 10 W0205008 Message Fewer than xxx or more than yyy values cannot be specified Explanation This message appears when an out of range value is entered into a number input area in the properties or the like Action by Use
69. of blocks necessary for being set was not able to be secured Please review the range of the address or release other blocks E1890500 Message The specified range of the address exceeds the capacity of code coverage RAM 2MB E1890501 Message The specified range of the address exceeds the capacity of code coverage RAM 1MB E1890502 Message The code coverage function is invalid The memory cannot be allocated E1890600 Message The specified range of the address exceeds the capacity of data coverage RAM 512k byte E1890601 Message The data coverage function is invalid The memory cannot be allocated E1890900 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 A number of blocks necessary for being set was not able to be secured Please review the range of the address or release other blocks ztENESAS Page 96 of 152 CS V3 00 00 E1890901 Message 5 MESSAGES The specified range of the address exceeds the capacity of profile RAM 1MB E1891102 Message The RAM monitoring block for uninitialization detection cannot be set any further E1891103 Message The section name is empty E1891104 Message The section name is invalid E1891105 Message The data is empty E1891106 Message The data is invalid E1891107 Message The start address is empty E1891108 Message The en
70. on CS Action by User Close a few Editor panels E0244001 Message The address range is invalid Can not specify address range that contain sections the endianness is different Explanation This appears when an address range is specified whose start and end addresses cause it to overlap areas with different endianness Action by User Specify a range that does not overlap areas with different endianness E0255001 Message Could not select the specified font Explanation This appears when an exception is thrown from the Font dialog box Action by User Select an available font E0261001 Message Generating link directive file failed Explanation This appears when the application fails to generate a link directive file Action by User Enter correct settings Make sure that the file is writeable Make sure that the project file is writeable allows appends E0261002 Message Copying is failed It isn t possible to include this section attribute in a segment of designation by a cause of the attribute Explanation This appears when trying to copy a section into a segment where that section can not appear due to the attribute settings Action by User Change the attributes of the section to copy Change the attributes of the segment to copy into E0261003 Message Opening link directive file generation dialog faile
71. only CS Utilities are installed as CS related tools All CS related tools need to be uninstalled in advance if you wish to change the installation folder Delete CS Utilities before starting the installation process Action by User Uninstall CS Utilities before starting up the integrated installer R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 21 of 152 CS V3 00 00 E0140030 Message 5 MESSAGES Cannot open the install information file xxx Canceling installation Explanation This error appears if the preparing installation window could not be displayed when running the self extracting file for the free tools E0140034 Message A file necessary for uninstalling this product was not able to be read and or write Canceling uninstallation Explanation This appears when the integrated uninstaller was not able to obtain the information necessary to uninstall the CS Utilities Action by User To uninstall all CS products manually remove CS Utilities using the Windows uninstallation functionality E0140036 Message Cannot obtain information required for installation Canceling installation Explanation This appears when the installer is unable to get the required information from the OS and determines that it is not appropriate to continue with the installation E0140038 Message The following product failed in in
72. or your Renesas Electronics overseas representative E0112998 Message A connection with the server could not be established Action by User Please contact your vendor or your Renesas Electronics overseas representative E0112999 Message The server returned an error Please retry the operation after a while Action by User Please contact your vendor or your Renesas Electronics overseas representative E0113000 Message A connection with the server could not be established Cannot find server or DNS error Action by User Make sure that you can display Internet sites in Internet Explorer Contact your network administrator if you cannot If you can display Internet sites there is probably a temporary issue with the server Please try again after waiting for a while E0113001 Message A connection with the server could not be established Action by User Make sure that you can display secure Internet sites starting with https in Internet Explorer Contact your network administrator if you cannot If you can display Internet sites there is probably a temporary issue with the server Please try again after waiting for a while E0113002 Message A complete response was not received from the server The server may have a problem Please retry the operation after a while Action by User If this error persists please contact your vendor or y
73. persists please contact your vendor or your Renesas Electronics over seas representative E0120011 Message Installer is untrusted Digital signature could not be validated Root certificate store in Windows may be old E0130000 Message Please select the object to copy E0130001 Message Please select the object to delete E0130002 Message Please select the object to restore E0130003 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Failed to delete xxx ztENESAS Page 19 of 152 CS V3 00 00 E0140001 Message 5 MESSAGES This product is not guaranteed on the Windows xxx operating system Cannot install this product Canceling installation Explanation This appears when starting the integrated installer on a non guaranteed version of Windows E0140002 Message Cannot write installation information because user rights are not set to the appro priate level Administrator rights are required to install this product Canceling installation Explanation This appears when started by a user without administrator privileges E0140003 Message NET Framework 4 is not installed NET Framework 4 is required to install this product Canceling installation Explanation This appears when the integrated installer is started on a host machine without the NET Framework 4 installed E0140005 Message Canno
74. range 0 to 65 535 Action by User Enter a correct value E1310724 Message Illegal default voltage Explanation The initial voltage specified in the I O panel Level Gauge Settings is invalid or out side the valid range 0 to the maximum input value setting Action by User Enter a correct value E1310730 Message Can t change any properties while programis running Explanation The object property sheet cannot be manipulated in the I O panel while the pro gram is running Action by User Perform the action after halting program execution E1310740 Message Programis running Explanation Processing cannot be performed in the I O panel because the program is running Action by User Perform the action after halting program execution E1310800 Message The interface address is invalid Explanation The setting interface address is invalid in standard library interface page Action by User Set a correct value E1310900 Message Illegal baudrate value Explanation The baud rate specified in the Format Settings dialog box UART is not a valid number Action by User Refer to the User s Manual for the device and specify an integral value within the appropriate range E1310901 Message Illegal transfer clock value Explanation The transfer clock value specified in the Format Settings dialog box CSI is not a valid number Action by User Refer to the User s Manual for the device and specify an integral value wit
75. results freeing the memory and closing the analysis plug in panel No This continues the task without discarding analysis results Operation may become unstable from this point because the application is working at the limits of memory capacity Q0812001 Message The break point can be set to two or more addresses Set the break point to all the addresses Explanation This appears to confirm whether to set a break to all corresponding addresses when you have selected the Set Break to Function command and the target func tion is a template function Action by User Yes This sets break events to all addresses corresponding to the template function No This sets a break event only to address with the smallest value corresponding to the template function Q0824001 Message No data corresponding to the search conditions was found Is the search continued from the xxx Explanation This appears when searching analysis graph value trends and the specified value is not found in the direction of search start or end is displayed in xxx Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Yes Close the Message dialog box and perform the search again from the beginning end of the range No Close the Message dialog box and move the focus to the original dialog box ztENESAS Page 125 of 152 CS V3 00 00 Q0824002 Message 5 MESSAGE
76. size E1236869 Message This feature is not supported E1236870 Message Please change PSW register not by 1 bit but by 8 bits E1240961 Message Illegal expression E1240962 Message Start address is bigger than the end address E1240963 Message Illegal source path E1240964 Message Too long expression E1240965 Message Not enough memory E1240966 Message Illegal argument E1240967 Message Illegal program number E1240968 Message Source path is not set E1240969 Message File not found E1240970 Message Can not open file E1240971 Message Can not close file E1240972 Message Failed in reading file E1240973 Message Not source file of load module E1240974 Message Illegal line number E1240975 Message Variable does not exist R20UT3099EJ0100 Rev 1 00 ztENESAS Page 64 of 152 Aug 01 2014 CS V3 00 00 E1240976 Message 5 MESSAGES Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect UThere may have been an error in the USB connection e g power or c
77. string that can be encoded with xxx Explanation This appears when characters are specified for a text search the Memory Search dialog box that cannot be displayed in the current encoding format of the Memory panel Action by User Specify characters that can be encoded W0247001 Message There is no available action event to set the specified location Explanation This appears when the Action Events dialog box is opened and there are no action events that can be configured Action by User Specify a different location W0249001 Message Clear out the category to be deleted Explanation This message appears when a non empty category is selected in the SFR IOR panel and the Delete EditDelete command is selected Action by User Make the category empty In the SFR IOR panel delete the categories below the category you wish to delete after moving SFR IOR below them W0261001 Message The segment name is invalid The characters 0 9 A Z a z _ can be used only Explanation This appears when a segment name is specified in the Link Directive File Genera tion dialog box using illegal characters Action by User Specify the segment name using valid characters W0261002 Message A segment with the same name already exists Explanation This appears when an existing segment name is specified in the Link Directive File Generation dialog box Action by User Change the name of the segment to one that
78. than four E1 or E20 emulators are connected to the host machine E1204096 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Failed in initializing Emulator ztENESAS Page 58 of 152 CS V3 00 00 5 MESSAGES E1204097 Message No entry exists for specified number E1204098 Message Can not relocate internal RAM E1204099 Message Illegal relocation address E1204100 Message Illegal condition E1204101 Message Invalid attribute E1204102 Message Illegal address E1204103 Message Not enough memory on Emulator E1204104 Message Not enough memory for tables E1204105 Message Already initialized E1204106 Message Not initialized E1204107 Message User program is running E1204108 Message Different bus size has been already specified E1204109 Message Too large bus size E1204110 Message Too large bus partition size E1204112 Message Illegal map range E1204113 Message Failed in setting internal ROM and RAM E1204114 Message This feature is not supported E1204115 Message No terminal name E1204117 Message Programmable lOR does not exist E1204118 Message Programmable IOR does not movable E1204119 Message I O Protect mapping is possible a target attribute only E1204120 Message Illegal internal ROM size E1204121 Message Illegal internal ROM size or internal RAM size E1
79. the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect UThere may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1200266 Message Cannot run debugger and a utility at the same time E1200416 Message No response from the emulation CPU Please confirm the signal of the CLOCK or RESET WAIT and so on E1200417 Message Failed in reading ie703000 ie E1200418 Message Break board is not connected E1200419 Message Emulation board is not connected E1200420 Message There is contradiction between the choice device and the connection emulator The debugger is aborted E1200421 Message POD EM board is not connected E1200422 Message Executor is running E1200424 Message Failed in reading initialization file expc ini E1200429 Message Please update the device driver for the PC interface board E1200430 Message Failed in reading initialization file expc ini E1200431 Message Failed in executing monitor command E1200432 Message Can not communicate with monitor program Please check the availability of com munication port the setting of CPU board or the type of cab
80. the upper limit of its valid range and the sizes of the upper and lower limits are reversed Action by User Enter a upper limit that is larger than the lower limit If you will also enter a smaller lower limit enter the value for the lower limit first W0805008_ Message Fewer than xxx or more than yyy values cannot be specified Explanation This message appears when an out of bounds value is entered into a numeric input area in the properties or the like Action by User Specify a value between xxx and yyy W0805009_ Message The file name or path name is invalid The characters lt gt cannot be used Explanation The string includes illegal characters Action by User Specify a valid path name W0820001 Message Unknown destination Explanation This message appears when a destination is unknown when executing the Jump to Source menu command etc It is not possible to jump from specified location because a destination is unknown W0827001 Message Can not preview image Explanation This message appears when the generation of preview images was not possible due to the project having too many functions or another reason W1200723 Message The specified trace buffer size has been reduced due to memory shortage W1203106 Message Memory unready status was canceled W1204111 Message Target is not turned on W1204116 Message Data is not exist W1216403 Message Access size is
81. when compiling a script fails Action by User Specify a correct script E1730002 Message Failed to register callback direct cause Explanation This appears on failure to register a callback class Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Initialize the server ztENESAS Page 89 of 152 CS V3 00 00 5 MESSAGES E1730003 Message Failed to unregister the callback direct cause Explanation This appears on failure to unregister a callback class Action by User Initialize the server E1810000 Message The specified parameter is incorrect E1810001 Message An undefined emulator firmware command has been received E1810002 Message The firmware verson may be older to use the debugger Action by User Check that the latest firmware is in use E1810200 Message An error has occurred in erasing of the flash ROM for storage of the emulator firm ware E1810201 Message An error has occurred in programming of the flash ROM for storage of the emulator firmware E1810203 Message An error has occurred during FPGA configuration E1810306 Message An error has occurred in erasing of the internal flash ROM The flash ROM may have been degraded E1810307 Message An error has occurred in programming of the on chip flash ROM The flash ROM may have been degraded E1810309 Message The setting of the peripheral
82. wrong E1249157 Message Illegal file type E1249158 Message Kind Chip of load module is illegal E1249159 Message Specified file is not load module E1249161 Message Not enough memory E1249162 Message No mapped address was accessed E1249163 Message Load module is not loaded E1249164 Message Illegal argument E1249165 Message User program is running E1249166 Message User program is being traced E1249167 Message Interrupted R20UT3099EJ0100 Rev 1 00 ztENESAS Page 67 of 152 Aug 01 2014 CS V3 00 00 E1249168 Message 5 MESSAGES Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1249169 Message Illegal load module file format E1249170
83. 0 00 E0210010 Message 5 MESSAGES This operation has been cancelled because not currently allowed to disconnect from the debug tool Explanation This message appears when disconnection of the debugging tool was attempted even though this was not allowed Action by User Stop the debugger if it is operating E0213001 Message Initializing microcontroller information failed Explanation This error occurs when attempting to load or convert a project that uses information for a device that is not installed The device information file is corrupt E0213002 Message The specified microcontroller is unsupported Explanation This error occurs when attempting to load or convert a project that uses information for a device that is not installed The device information file is corrupt E0213003 Message Getting microcontroller information failed Explanation This error occurs when getting target information failed when using microcontroller information Action by User Make sure that correct microcontroller information file is installed E0218003 Message Unknown command line options xxx were specified Explanation This appears when an option was specified that was not processed by the IDE ora plugin Action by User Specify the options correctly E0218004 Message Command line options bb bc bcb and br are mu
84. 000 Message Failed to read download source The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111001 Message An internal error occurred in Update Manager Failed to write downloaded file Action by User Please contact your vendor or your Renesas Electronics overseas representative E0111002 Message An internal error occurred in Update Manager Failed to download Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Please contact your vendor or your Renesas Electronics overseas representative ztENESAS Page 14 of 152 CS V3 00 00 5 MESSAGES E0111003 Message Download source is invalid The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111004 Message Failed to write downloaded file The response from the server was not co
85. 001 Message option name is unknown option ignore Explanation The specified option is not supported The setting is ignored and processing is continued W2200003 Message file name is exist overwrite y n Explanation A file with the specified name already exists Action by User y The existing file is overwritten and processing continues n Processing is aborted W2200101 Message option name is unknown option ignore Explanation The specified option is not supported This specification is ignored and processing continues R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 148 of 152 Revision Record Description Summary Aug 01 2014 First Edition issued CS V3 00 00 User s Manual Message Publication Date Rev 1 00 Aug 01 2014 Published by Renesas Electronics Corporation CENESAS SALES OFFICES Renesas Electronics Corporation http www renesas com Refer to http Awww renesas com for the latest and detailed information Renesas Electronics America Inc 2801 Scott Boulevard Santa Clara CA 95050 2549 U S A Tel 1 408 588 6000 Fax 1 408 588 6130 Renesas Electronics Canada Limited 1101 Nicholson Road Newmarket Ontario L3Y 9C3 Canada Tel 1 905 898 5441 Fax 1 905 898 3220 Renesas Electronics Europe Limited Dukes Meadow Millboard Road Bourne End Buckinghamshire SL8 5FH U K Tel 44 1628 585 100 Fax 44 1628 585 900 Renesa
86. 009 Message The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111010 Message The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 15 of 152 CS V3 00 00 E0111011 Message 5 MESSAGES Failed to resume download Please retry the operation Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111012 Message Failed to write downloaded file xxx Aborting the download Action by User Check the free space of the disk When being no problem make sure that it is possible to write files in the path spec ified in the message If you cannot identify the cause please contact your vendor or your Renesas Elec tronics overseas representative E0111013 Message Failed to wri
87. 0231001 Message Specify the file to be downloaded Explanation This message appears when from the Download Files dialog box the user clicks OK with the added download item file path left empty Action by User Set the file path W0233001 Message Could not move to the definition location of the function Specify the function Explanation Failed to move to the function definition specified in the Editor panel Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify the function in the Editor panel 2tENESAS Page 133 of 152 CS V3 00 00 W0235001 Message 5 MESSAGES The specified xxx does not exist Explanation This appears when the user called the Go To The Location dialog box from the SFR IOR panel and a non existent SFR IOR name was specified Action by User Specify an existing SFR IOR W0238001 Message The information of project files the information of source files and the window images are output Remove these information if there is a confidential problem Explanation This message appears in response to clicking on the Recode Screen button in the Message dialog box W0240001 Message Could not move to the definition location of the symbol Specify the symbol Explanation Failed to move to the definition of the specified symbol from the Disassemble panel Action by User Specif
88. 032 Message The following activation source conflicts have been detected W0403033 Message To use xxx please release yyy in zzz module firstly W0403034 Message The following xxx conflicts have been detected W0403035 Message Please set at least 2 slaves W0403036 Message To use this selection please unselect noise filter sampling clock from another channel W0403037 Message Please set only 1 slave W0403038 Message The combination operation can t be selected because its master channel has been used for other purposes W0403039 Message Please set master channel first W0403040 Message Setting is not valid because xxx is selected W0403041 Message Setting is not valid because no channel is used as analog input W0403042 Message Setting is not valid because xxx is changed W0403043 Message Setting is not valid because High speed main mode is not used in System mod ule W0403044 Message Please select one valid item W0403045 Message Please input valid RAM address symbol W0403046 Message There is an error in a set item The source generation cannot be executed W0403047 Message Input source setting is not valid W0403048 Message To use xxx please release yyy module firstly W0403049 Message Comparator reference voltage is internal reference voltage the temperature sensor output cannot be A D converted W0403050 Message Please select xxx yyy MHz
89. 05 Message The external flash area doesn t exist E0608006 Message The address was acquired and the ID Tag was not able to be acquired illegally E0608007 Message The address range is invalid Can not specify address range that contain sections the endianness is different E0608009 Message Accessed the memory area you can t access during execution Explanation Changing the settings of the Access Memory While Running category on the Debug Tool Settings tabbed page of the Property panel may lead to access to some memory areas during execution of the program E0611000 Message Failed to convert address xxx E0613000 Message The memory can t be read because the stop during the moment isn t permitted E0613001 Message The memory can t be written because the stop during the moment isn t permitted E0613002 Message The register can t be read because the stop during the moment isn t permitted E0613003 Message The register can t be written because the stop during the moment isn t permitted E0613004 Message The Sfr can t be read because the stop during the moment isn t permitted E0613005 Message The Sfr can t be written because the stop during the moment isn t permitted E0613006 Message The breakpoint can t be set because the stop during the moment isn t permitted E0613007 Message The breakpoint can t be deleted because the stop during the moment isn t permit ted
90. 06 Message Program analysis information is being generated The trace data is acquired and analyzed Action by User If you wish to suspend then click Cancel M0810007 Message Program analysis information is being generated The coverage data is acquired and analyzed M0812001 Message The buffer of the trace was filled There is a possibility that the result of Analysis panels is incorrect Explanation This appears when the trace buffer is full when program execution is stopped Action by User Narrow the range of analysis M0812002 Message Some trace data was lost There is a possibility that the result of Analysis panels is incorrect Explanation This appears when trace data has been dropped during trace data analysis Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Narrow the range of analysis ztENESAS Page 107 of 152 CS V3 00 00 M0812003 Message 5 MESSAGES The trace of the instruction was not included in the trace data Please confirm the setting of the trace There is a possibility that a part of the result of Analysis panels is not displayed Explanation This appears when the trace data being analyzed does not contain an M1 BRM1 fetch Action by User Check the trace output settings M0812004 Message The trace of the data access was not included in the trace data Please confirm t
91. 0603022 Message The address expression is invalid Specify a symbol or numerical value Explanation This message appears when a string that is invalid as an address expression is entered in an address expression area Action by User Specify a string that is correct as an address expression W0603030 Message The load module which linked the flash library not found W0603032 Message Specify the address of the 1MB boundary unit as the starting address of coverage measurement area W0603034 Message Specified value is already set W0617000 Message Set OPJTAG in LPD for debug tool connection Action by User The debug tool forcibly changes the OPJTAG setting to select LPD upon its con nection to CS If you set the Set OPUTAG in JTAG connection before disconnecting property to Yes the JTAG connection will be restored after the debug tool is disconnected W0810001 Message A variable or a register with the input name doesn t exist W0805001 Message Specify in decimal Explanation This message appears when a string containing characters that are invalid as a decimal number was entered in a decimal base 10 numeric field Action by User Specify a string that represents a valid number in decimal notation W0805002 Message Specify in decimal or hexadecimal Explanation This appears when an area specifying
92. 1 Message Overlaps xxx Explanation et a size in the internal ROM size property that is different from other mapping areas A value was set in the Mapping dialog box that overlaps with other mapping areas xxxis a list of overlapping areas separated by commas Action by User Set the value so that it does not overlap with other areas W0212002 Message The specified I O protection area does not fit within single target memory area Explanation The specified I O protected area must fit inside a single configured target memory area This message appears when the specified area protrudes from a single tar get memory area Action by User Specify an area range that will fit inside a single target memory area W0222001 Message The list of microcontrollers has not been updated Explanation This appears when an exception was thrown from the update library such as when there are no updates or a restart is required Action by User Follow the instructions in the message W0223001 Message Source files were added to the Project Tree panel but some files does not exist Explanation When a debug project is downloaded source files included in the load module are added automatically This appears when any of the source files to be added are not on the file system Action by User Add the source files manually to the Project Tree panel W
93. 204122 Message Specified Simulator configuration file was not found E1204123 Message Simulator configuration file was not specified E1204124 Message Illegal Simulator configuration file E1204125 Message DataFlash area does not movable E1204126 Message DataFlash area does not exist E1204127 Message Can not be specified with ID Tag R20UT3099EJ0100 Rev 1 00 ztENESAS Page 59 of 152 Aug 01 2014 CS V3 00 00 E1204351 Message 5 MESSAGES Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1207614 Message Error occurred inside debugger E1208193 Message Illegal address E1208194 Message User program is running E1208196 Message Illegal bit number
94. 20UT3099EJ0100 Rev 1 00 Aug 01 2014 Illegal event link condition ztENESAS Page 61 of 152 CS V3 00 00 E1216400 Message 5 MESSAGES Function not found E1216401 Message Not enough memory E1216402 Message Timer is being disabled E1216404 Message Can not use software break E1216405 Message Can not use event condition specifying address range E1216406 Message Can not change event condition E1216407 Message Can not access word at odd address E1216408 Message Not enough memory E1216409 Message This feature is not supported E1216410 Message No Event E1216411 Message Can not use tag event E1216413 Message Start event and end event of timer are not made to the same setup E1216414 Message Too many trace events E1216415 Message Path count cannot be set up E1216416 Message Address range cannot be set up in event before execution E1216417 Message Event conditions number overflow E1216418 Message Software DMM conditions number overflow E1216419 Message Real time call conditions number overflow E1216420 Message Software break call conditions number overflow E1216421 Message Illegal snap condition E1216422 Message Too many event conditions cannot be set as Phase1 a
95. 3 Message Cannot find terminal information file xxxx E0025004 Message Cannot find device extended file xxxx E0025005 Message Cannot read file E0100000 Message Failed to start the CS update manager Please install CS again E0100003 Message Failed to start xxx Failed to read yyy Action by User Reinstall CS If this does not resolve the problem reinstall after deleting all files in the folder con taining file noted in the message E0100004 Message Failed to write xxx Action by User Reinstall CS If this does not resolve the problem reinstall after deleting all files in the folder con taining file noted in the message E0100005 Message Failed to start xxx Action by User If it occurred in the installer perform the update again If it occurred in an installed tool reinstall it E0100006 Message Failed to restart xxx Action by User Start manually E0100007 Message The CS update manager is not installed Action by User Install CS update manager E0100008 Message Can not start this CS update manager because it is moved from its installed folder Action by User Start up the CS update manager from the Start menu E0100009 Message Failed to read xxx Action by User Reinstall CS If this does not resolve the problem
96. 891314 Message An on chip break point has already been set to the address E1891315 Message The on chip break point cannot be added any further E1891316 Message Target event is not found E1891317 Message Failed to get information of the event E1891318 Message Value of the mask is invalid E1891319 Message Value of the compare data is invalid E1891320 Message Value of the pass count is invalid E1891321 Message Value of the pass count exceeds the range E1891323 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Unable to evaluate the value Failed to create event ztENESAS Page 97 of 152 CS V3 00 00 E1891324 Message 5 MESSAGES Value of the frequency is invalid E1891325 Message Sequential orderxx event is incorrect or over resources E1891326 Message The reset event for sequential combination is incorrect E1891327 Message The event related to the other event can not be changed its enabled disabled sta tus E1891328 Message Failed to enable the event E1891329 Message The AND condition and the sequential condition are used at the same time E1891331 Message The pass count can be set only for one event E1891332 Message Data Access events can be used up to 3rd order E1891333 Message The event with address range
97. Action by User There could be a problem with the file contents E0201016 Message Creating the folder xxx failed Explanation This message appears when a folder could not be created Action by User Check the access privileges to the folder E0202001 Message New project creation failed Explanation This message appears when the program fails to create a project Action by User Follow the instructions in the message to remedy the problem E0202002 Message Opening a project failed Explanation This message appears when the program fails to load a project Action by User Follow the instructions in the message to remedy the problem E0202003 Message Saving a project failed Explanation This message appears when the program fails to save a project Action by User Follow the instructions in the message to remedy the problem E0202004 Message Packing a project failed Explanation This message appears when the program fails to pack a project Action by User Make sure that an invalid path is not specified as the pack destination folder Make sure that the pack destination folder is not read only E0202005 Message The project file is broken Explanation This error occurs when the program fails to parse a file Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014
98. Action by User Check the memory wait cycle setting W1811338 Message Warning The wait setting for the ROM was changed temporarily to access it cor rectly Explanation The memory wait cycle setting is incorrect Action by User Check the memory wait cycle setting W1812808 Message There was a sector that could not be written erased in the external flash ROM because it was locked W1891371 Message Order of the sequential event might have been modified Please check the detail setting of the event combination Action by User Set the event sequence again by editing the combination of conditions W1891901 Message Because the value of the operating frequency has not been set 25 0MHz is used as its initial value The timer measurement result may be incorrect W1892250 Message Register ID is invalid Action by User Specify the correct register ID W1892251 Message The specified value is over the maximum value which can be set to the register Action by User Enter a value within the specifiable range W2000001 Message The function xxx cannot be found Explanation This message dialog box appears when the selected function name cannot be jumped to using the Jump to function operation W2000003_ Message The symbol or address xxx cannot be found Explanation This message appears when the given symbol or address was not found so jump ing to the location of the symbol or the address was not possible W2200
99. E1720019 Message A setup of a library file went wrong direct cause Explanation This appears on failure to set the library file of link option E1720020 Message Renewal of a dependency went wrong direct cause Explanation This appears when renewal of a dependency went wrong E1720021 Message The not corresponding build tool is set up Explanation This appears when a build tool to which a Python console doesn t correspond is set up E1720022 Message The exception occurred within the event direct cause Explanation This appears when an exception occurred in the method connected to BuildCom pleted Action by User Modify the connected method E1720023 Message Too many build modes Explanation If a non existent build mode is specified it is added as a new build mode This message appears when the number of build modes exceeds the maximum E1720024 Message Failed to get the include paths direct cause Explanation This appears when reference to Additional include paths in the compiler property failed E1720025 Message Failed to set the include paths direct cause Explanation This appears when setting to Additional include paths in the compiler property failed E1720026 Message The build mode name is invalid The following characters cannot be used 2
100. E1891369 Message Specified event type does not support the combination AND Sequential E1891372 Message Specified combination condition is incorrect E1891373 Message Specified address comparison condition is incorrect E1891374 Message Specified data comparison condition is incorrect E1891375 Message Specified events for the combination condition are incorrect E1891500 Message The block cannot be set any further E1891501 Message The table cannot be set any further E1891600 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message The block cannot be set any further ztENESAS Page 98 of 152 CS V3 00 00 E1891601 Message 5 MESSAGES The table cannot be set any further E1891602 Message The entire range exceeds it to 4K E1891603 Message The input value of task ID is up to max block size E1891604 Message The start end address acquisition failed E1891605 Message TaskID acquisition failed E1891606 Message TaskID is wrong E1891607 Message The area size is exaggerated E1891608 Message Task ID has already been set E1891609 Message The range has already been set E1891610 Message Failed in the block conversion E1891700 Message Operation was canceled E1891701 Message Cannot detect the user syste
101. Installation location gt CS UpdateManager exe E0115000 Message Download was canceled E0115001 Message An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0119999 Message An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0120001 Message Failed to download XXX E0120002 Message Download was aborted E0120003 Message Because downloading related updates are failed installation was aborted E0120004 Message Installation was aborted E0120005 Message Install failure Error code xxx E0120006 Message Another program is running an update Please run the update after the current update is completed E0120007 Message Failed to acquire administrative privileges Action by User If you specified a user who is not an administrator perform the action again E0120008 Message Because installing related updates are failed installation was aborted E0120009 Message Can not find the installer Action by User Perform the update again E0120010 Message Downloaded file was broken Please retry the operation Action by User If this error
102. M0409003 Message The operation of generating file was successful M0409004 Message xxx Was overwrited M0409005 Message Pin No xxx was changed from yyy to zzz M0409006 Message Start to reflect to PinConfig M0409007 Message Finish reflecting to PinConfig M0409008 Message The code generator report is output to the following files M0409100 Message The device top view is output to the following files Explanation This is to notify you of the files in which the device top view has been saved M0409101 Message The device list view is output to the following files Explanation This is to notify you of the files in which the device list view has been saved M0607000 Message Stopped to step because the debug target operating mode is different the device operating mode Please Change the debug target operating mode to the device operating mode M0810001 Message Could not change the setting that output the cross reference files Explanation This error occurs when the Enable static analysis information property is set to Yes and the compiler properties could not be manipulated immediately prior to the build M0810003 Message Failed to analyze cross reference information Action by User Execute the build after setting Enable static analysis information property to Yes M08100
103. Message Failed to start up with the hot plug in The specified UB code does not match the current code E1814602 Message Failed to start up with the hot plug in The specified operating mode is user boot mode E1815000 Message A timeout error has occurred in EFW processing The location of the error is unknown R20UT3099EJ0100 Rev 1 00 ztENESAS Page 94 of 152 Aug 01 2014 CS V3 00 00 E1815001 Message 5 MESSAGES A timeout error has occurred in emulator firmware processing E1815002 Message A timeout error has occurred in START STOP function processing E1816000 Message FFWERR_TRGHALT_OK E1816100 Message FFWERR_TRGHALT_NGBFWRUN E1816101 Message FFWERR_TRGHALT_NGEFWRUN E1817000 Message A fatal communication error Disconnect the debugger and check if the emulator is correctly connected to the target board Then turn on the power of the emulator and initiate the debugger E1817001 Message A communication error An incorrect start code has been received from emulator firmware Please restart the emulator and the debugger E1817002 Message A communication error An incorrect command code has been received from emu lator firmware Please restart the emulator and the debugger E1817003 Message A communication error An undefined error code or termination code has been received from emulator firmware or the combination of the error c
104. Message Xxxx isn t a device file E0023006 Message V850 microcontroller is not supported E0023007 Message 78K microcontroller is not supported E0023008 Message 78K0 78KOS and V850 microcontroller are not supported E0023009 Message RL78 Family 78KOR microcontroller is not supported E0023010 Message RL78 Family 78KOR and V850 microcontroller are not supported E0023011 Message Cannot find CategoryName xxxx E0023012 Message V850E2 microcontroller is not supported E0023013 Message 78K0 78KOS microcontroller is not supported E0023014 Message 78KO microcontroller is not supported E0023015 Message Duplicate Device dependent information files exist Delete from Device_custom folder Please delete Device dependent information file from Device_custom folder aaaa bbbb Please delete both Device dependent information file and list file in the Device_Custom folder E0023017 Message RX microcontroller is not supported E0023018 Message RH850 microcontroller is not supported E0024001 Message Not Support this device xxxx E0024002 Message Cannot find device extended file xxxx E0024003 Message Cannot read file E0025001 Message Not Support this device xxxx R20UT3099EJ0100 Rev 1 00 ztENESAS Page 12 of 152 Aug 01 2014 CS V3 00 00 E0025002 Message 5 MESSAGES Cannot find device file xxxx E002500
105. Page 103 of 152 CS V3 00 00 M0201007 Message 5 MESSAGES Loading xxx Explanation This appears when a file is open M0201008 Message Xxx is saved after replacing the unexpressible characters by the current encode yyy Explanation This appears when saving the file that is open in the editor and it cannot be saved correctly with the specified encoding Action by User Change the encoding and then save the file M0202001 Message Loading PM project Explanation This message appears in the Progress Status dialog box while a PM project file is being loaded M0202002 Message Creating project file Explanation This message appears in the Progress Status dialog box while a project file is being created M0202003 Message Loading project Explanation This message appears in the Progress Status dialog box while a project file is being loaded M0202004 Message Converting project file Explanation This message appears in the Progress Status dialog box while a project file for another product is being converted M0202005 Message Packing project Explanation This message appears in the Progress Status dialog box while a project file for another product is being converted M0202006 Message Loading project Explanation This message appears in the Progr
106. ROM to RAM E1720032 Message Failed to set the ROM to RAM mapped section direct cause Explanation This appears when the current linker does not support section mapping from ROM to RAM or when an illegal value is specified Action by User Correct the setting when it is illegal E1720033 Message Failed to get the the specified section that outputs externally defined symbols to the file direct cause Explanation This appears when the current linker does not support setting of a section from which externally defined symbols are output to a file E1720034 Message Failed to set the specified section that outputs externally defined symbols to the file direct cause Explanation This appears when the current linker does not support setting of a section from which externally defined symbols are output to a file or when an illegal value is specified Action by User Correct the setting when it is illegal E1720035 Message Failed to get the output ROMized object file direct cause Explanation This appears when the current ROMization process option does not support Out put ROMized object file E1720036 Message Failed to set the output ROMized object file direct cause Explanation This appears when the current ROMization process option does not support Out put ROMized object file or when an illegal value is specifie
107. S Restore the values of Variable Address and Type Size to the values before loading from a file Explanation This appears when you have selected Load from file for the analyze tool s Prop erty panel gt gt Variable Value Changing tab gt gt Analysis method property and then changed to another method It confirms whether to restore the property setting to the values before loading from file Action by User Yes Discards the values loaded from file and restores the previous values No Retains the values loaded from file Q0826001 Message When you save an image in this format may be very large file size Explanation This warns that the size of the file is large and confirms whether to really save it Action by User OK Save the image Cancel Do nothing Q1700000 Message The file xxx cannot be saved as it is Read Only Would you like to save the file as a different name or overwrite it Explanation This message appears when a read only file is to be overwritten Action by User Save As Save the file as a different name Overwrite The attribute of the file is changed and it s overwritten Cancel Cancel action Q2000001 Message The current editor file contains unsaved changes You must save these changes first xxxyyy Would you like to save the changes to this file Explanation This message dialog box appe
108. UT3099EJ0100 Rev 1 00 Aug 01 2014 Yes Delete the entire memory area No Cancel delete ztENESAS Page 119 of 152 CS V3 00 00 5 MESSAGES Q0261003 Message The memory area has been set the specified segment Also delete the segment Explanation This message appears when a segment is included in the memory area that is to be deleted Action by User Yes Delete the entire memory area No Cancel delete Q0261004 Message Some of the segments that are set in the memory area that have changed fall out side the range of address Continue saving and processing If you continue the start address of the segment is outside the range will be empty Explanation This message appears when some of the segments in the memory area that has been changed are located outside the specified address range Action by User Yes Apply the change The addresses of the segments located outside the specified address range will be blank No Cancel the change Q0262001 Message This product recommends that creating project at the same place as the original project folder Are you sure you want to change the project folder Selected folder xxx Recommended folder diverted project folder yyy Build error may be occurred in the creating project Because the folder for a cre ating project is different from the original Explanation In the Create Project dialog box if t
109. a decimal nexadecimal number includes characters that cannot be used to represent a decimal hexadecimal number Action by User Specify a string that represents a valid number in decimal hexadecimal notation W0805003 Message The character string is too long Specify a character string with xxx or fewer charac ters Explanation This message appears when a string was specified in a string area that was longer than the maximum length Action by User Specify a string of no more than the maximum number of characters W0805004 Message Please input a value that is smaller than the upper bound value to lower bound value Explanation This message appears when entering the lower limit of the display range of an analysis graph or the lower limit of its valid range and the sizes of the upper and lower limits are reversed Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Enter a lower limit that is smaller than the upper limit If you will also enter a larger upper limit enter the value for the upper limit first ztENESAS Page 145 of 152 CS V3 00 00 5 MESSAGES W0805005_ Message Please input a value that is bigger than lower bound value to the upper bound value Explanation This message appears when entering the upper limit of the display range of an analysis graph or
110. able dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1240977 Message Can not access register E1240978 Message Can not access memory E1240979 Message Reading of file went wrong E1240980 Message It was going to open the binary file E1240981 Message Can not get temporary path E1240982 Message Can not create temporary file E1240983 Message Can not remove temporary file E1240992 Message This feature is not supported E1240993 Message Symbol assigned to register cannot be specified E1240994 Message The character which cannot be used for the folder is contained or the folder does not exist E1245056 Message Illegal command line E1245057 Message Program information does not exist in specified load module file E1245058 Message File not found E1245059 Message Function not found E1245060 Message Selected load module different from kind Chip was loaded E1245061 Message Symbol not found E1245064 Message Illegal expression E1245065 Message Not enough memory E1245066 Message Illegal symbol in lo
111. ad module file E1245067 Message Current program does not exist E1245068 Message Current file does not exist E1245069 Message Current function does not exist E1245070 Message Current line does not exist E1245071 Message Tag not found E1245072 Message Failed in loading symbol information E1245073 Message Illegal line number E1245074 Message Too large line number E1245077 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Reading of file went wrong ztENESAS Page 65 of 152 CS V3 00 00 5 MESSAGES E1245078 Message Can not open file E1245079 Message Failed in writing file E1245081 Message Reading of file went wrong E1245082 Message Can not close file E1245083 Message Too long load module file name E1245084 Message Too many entries of the task kind E1245085 Message Address not found E1245087 Message Can not find structure member E1245088 Message Can not find value E1245089 Message There are neither debug information nor symbol information in load module file E1245090 Message Illegal line number E1245091 Message Current stack frame is not active E1245092 Message Different section E1245094 Message Too many array dimensions gt 4 E1245095 Message Found end of file E1245096 Message This feature
112. and security updates for this product using Windows Update and Microsoft Upadate Stop the installation Explanation This message appears when all installation of required environments has suc ceeded and a reboot is required for some of them but not for others W0190002 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Failed to read license information from xxx The file is broken ztENESAS Page 128 of 152 CS V3 00 00 w0200001 Message 5 MESSAGES There are multiple files used for inquiry and update in your PC The file should be unique Please reinstall xxx Explanation This appears when there is more than one information files used to update and obtain information about the software Perform the installation again Action by User Perform the installation again W0201003 Message Could not Change the Writable Explanation This message appears when can t change the reading exclusive use attribute of the target file Action by User Specify the file by which the current user can edit the attribute W0201004 Message Illegal extension of the file The extension of xxx must be specified for the exten sion of the file Explanation This appears when the extension of a file being loaded or imported is not sup ported Action by User Specify a file with a correct extension W0201005 Message llegal enc
113. ange the extension of the file has child nodes Explanation This message appears when an attempt is made to change the extension of a file that has child nodes Action by User Remove the child nodes from the project E0233001 Message No additional new panel could be opened Explanation This error occurs when a new Editor panel cannot be opened Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 A maximum of 100 Editor panels can be opened at once Close unneeded panels before opening new ones ztENESAS Page 43 of 152 CS V3 00 00 E0233002 Message 5 MESSAGES Binary files are not supported Explanation Appears when trying to load a binary file in the editor Action by User Open a text file E0233003 Message The specified file could not be displayed Explanation No application is assigned to the file s extension in the OS This message appears when the maximum number of editors is open This message appears when an external editor cannot be opened Action by User Check the access privileges to the file Reduce the number of open editors E0233004 Message The maximum number of editor panels exceeded Please close some editor panels to keep working Explanation This message appears when an attempt is made to open another Editor panel while the maximum number 100 of Editor panels have been open
114. ars when switching the Editor panel from source file view to mixed source view It is to inform the user that unsaved modifications have been made to the source file The user must agree to save any modifications to the source file before source mixed mode can be displayed Action by User OK The changes to the source file will be saved If the changes are saved successfully then the editor view will continue to switch to source mixed view Cancel Cancel the operation of switching to source mixed view The editor view will remain in source file view and the unsaved changes will remain Q2000002 Message xxx has been changed Save Explanation This message dialog box appears to prompt to save any unsaved modifications to the Editor panel This prompt occurs when performing operations such as closing the Editor panel or reloading the current editor file Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Yes This will save all unsaved modifications to the specified editor file No This will discard any unsaved modifications in the editor file Cancel This will cancel the operation that resulted in the prompt to save the file The Can cel button may not be avalable if the save request is due to the application closing ztENESAS Page 126 of 152 CS V3 00 00 Q2000004 Message 5 MESSAGES The file xxx cannot be saved as it is Read Only yyy Would you like t
115. ars when there is a file with information about the installation folder from the last install but the information could not be read E0140015 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message The specified installation destination drive does not exist or is on a network Please specify a local disk drive Explanation This appears when the installation folder contains specifies a non existent drive or invalid characters or a drive that is not a local disc ztENESAS Page 20 of 152 CS V3 00 00 5 MESSAGES E0140016 Message Invalid installation folder Explanation This appears when the character that cannot be used as a folder is specified for the folder at the installation destination E0140017 Message Not enough free disk space Please make enough free space on the installation destination Explanation This appears when there is not enough free disc space E0140019 Message Installation failed Please reboot your computer Explanation This appears when some tools failed to install but the installation was successful and the system must therefore be restarted E0140020 Message Installation failed The installation was aborted before finish Please reboot your computer Explanation This appears when the installation was aborted and some of the tools from the completed portion before cancellation failed to install but the ins
116. as zzz in System module before you want to use it W0403051 Message Please input a valid text W0403052_ Message Oscillation stop detection can be used under either of the following conditions When bit 0 WDSTBYON and bit 4 WDTON of the option byte 000C0H are set to 1 and bit 4 WUTMMCK0 of the OSMC register is set to 0 When bit 4 WUTMMCK0O of the OSMC register is set to 1 W0403053_ Message Please select xxx yyy MHz in System module before you want to use it W0403054 Message Setting is not valid because it has been set as analog input by ADPC register W0403055 Message Setting is not valid because it has been set as digital I O by ADPC register W0602102 Message Check the connection of the conversion adapter R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 142 of 152 CS V3 00 00 W0603001 Message 5 MESSAGES Fewer than xxx or more than yyy characters cannot be specified Explanation This message appears in the Message dialog box if a string is specified for the area that is shorter than xxx characters or longer than yyy characters when xxx and yyy are the minimum and maximum lengths respectively Action by User Xxx is the minimum length of the character string and yyy is the maximum length The values of xxx and yyy are dependent on the input area W0603002 Message More than xxx characters cannot be specified Explanation This messa
117. ation This appears when a reserved section with a fixed segment is specified within a dif ferent segment in the Link Directive File Generation dialog box Action by User Change the section to one that is not reserved W0261008 Message The TP symbol name is invalid Specified TP symbol name is no exist Explanation This appears in the case of a base TP symbol when the TP specified in the Link Directive File Generation dialog box does not exist Action by User Change to an existing TP symbol name W0261009 Message The memory area name is invalid The characters 0 9 A Z a z _ can be used only Explanation This message appears when invalid characters have been used for the name of a memory area in the Link Directive File Generation dialog box Action by User Only use valid characters for the names of memory areas W0261010 Message A memory area with the same name already exists Explanation This message appears when the name of an existing memory area has been spec ified in the Link Directive File Generation dialog box Action by User Change the name of the memory area W0261012 Message memory area range is invalid Place the area without overlap to other memory area Explanation This message appears when the address or size of a memory area specified in the Link Directive File Generation dialog box overlaps with that
118. ations or use by the military including but not limited to the development of weapons of mass destruction When exporting the Renesas Electronics products or technology described in this document you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations It is the responsibility of the buyer or distributor of Renesas Electronics products who distributes disposes of or otherwise places the product with a third party to notify such third party in advance of the contents and conditions set forth in this document Renesas Electronics assumes no responsibility for any losses incurred by you or third parties as a result of unauthorized use of Renesas Electronics products This document may not be reproduced or duplicated in any form in whole or in part without prior written consent of Renesas Electronics Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electronics products or if you have any other inquiries Note 1 Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority owned subsidiaries Note 2 Renesas Electronics product s means any product developed or manufactured by or for Renesas Electronics 2012 4 How to Use This Manual This manual describes the role of the CS integrated develo
119. ber of a trace event that does exist E1710170 Message Failed to enable the specified trace event direct cause Explanation This message appears when the debugger has failed to enable a trace event Action by User Solve the problem indicated as direct cause E1710171 Message Failed to disable the specified trace event direct cause Explanation This message appears when the debugger has failed to disable a trace event Action by User Solve the problem indicated as direct cause E1710172 Message Address condition is not set Explanation This message appears when an address condition was not specified Action by User Specify an address condition E1710173 Message Failed to set the trace event direct cause Explanation This message appears when the debugger has failed to set a trace event Action by User Solve the problem indicated as direct cause E1710174 Message The specified trace event type is illegal direct cause Explanation This message appears when the type condition of the specified trace event is ille gal Action by User Solve the problem indicated as direct cause E1710175 Message Failed to delete the specified trace event direct cause Explanation This message appears when the debugger has failed to delete a trace event Action by Use
120. bugger Explanation An invalid project was specified Action by User Specify a valid project E0292008 Message The project uses an unsupported target Explanation An invalid project was specified Action by User Specify a valid project E0292009 Message The conversion of project xxx was aborted Explanation The Cancel button was clicked in the Select Session dialog box E0292021 Message Project xxx cannot be converted The project is invalid Explanation The project file is invalid Action by User Specify a valid project file E0292022 Message Xxx was not found Explanation The project file was not found Action by User Specify a valid project file E0292023 Message Project xxx cannot be converted The project was created by an earlier version of HEW Please open it in HEW 4 07 00 or newer save the project and try again Explanation This appears when the project version is older than HEW 4 07 00 Action by User Open the project with HEW 4 07 00 or a later version save it and convert it again E0292024 Message xxx Session invalid Action by User Specify a valid project file R20UT3099EJ0100 Rev 1 00 Aug 01 2014 2tENESAS Page 46 of 152 CS V3 00 00 E0292025 Message 5 MESSAGES XXX was not found Explanation Session is invalid Action by User Specify a valid project file E0292026 Message Session xxx cannot be converted The session
121. by User Specify a channel number in the specifiable range E1830802 Message The measurement section is not being set to the specified channel number Action by User Specify a channel number that is set for the measurement section E1831301 Message C2E buffer has no data E1831400 Message I O DLL loading failed I O DLL name file name E1831500 Message The operating frequency of the system clock is outside the supported range E1831501 Message The ratio of peripheral clock is not correct E1833300 Message The command is not executable because the user program is running E1833301 Message The command is not executable because the user program is halted E1890001 Message Address range error The starting address should be smaller than the end address E1890002 Message Because the setting of the memory access prohibition under execution was effec tive this processing was interrupted E1890003 Message This function interrupted processing because it was not able to use it while execut ing it E1890004 Message The specified address is over the maximum address of the target MCU E1890101 Message This function cannot be used when debugging the program which rewrites the internal flash memory E1890324 Message The communication error occurred E1890400 Message A number
122. ce options to the project file Action by User Check the version of the project file E0202054 Message Restoring cross reference options failed Explanation Failed to restore cross reference options from the project file Action by User Check the version of the project file E0202055 Message Saving memory layout visualization options failed Explanation Failed to save memory layout visualization options to the project file Action by User Check the version of the project file E0202056 Message Restoring memory layout visualization options failed Explanation Failed to restore memory layout visualization options from the project file Action by User Check the version of the project file E0202057 Message Saving dump options failed Explanation Failed to save dump options to the project file Action by User Check the version of the project file E0202058 Message Restoring dump options failed Explanation Failed to restore dump options from the project file Action by User Check the version of the project file E0202059 Message Saving memory bank relocation options failed Explanation Failed to save memory bank allocation options to the project file Action by User Check the version of the project file E0202060 Message Restoring memory bank
123. connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1230721 Message Canceled step wait E1230722 Message End waiting state of step execution was canceled E1232512 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Aborted step execution ztENESAS Page 63 of 152 CS V3 00 00 5 MESSAGES E1232514 Message Suspended step execution E1232515 Message Failed in canceling RUN STEP E1232516 Message Can not execute non mapped area E1232517 Message This feature is not supported E1232768 Message Specified file was not found E1232769 Message Illegal line number E1232770 Message Current information is not set E1232771 Message Illegal address E1232772 Message This feature is not supported E1236864 Message Specified register symbol does not exist E1236865 Message Specified register symbol ID does not exist E1236866 Message Illegal value E1236867 Message Illegal condition E1236868 Message Too large register
124. create a folder when creating a file if the specified path includes a folder that does not exist Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Yes Create the folder No Close the dialog box ztENESAS Page 113 of 152 CS V3 00 00 Q0201004 Message 5 MESSAGES The file already exists Overwrite Explanation This message is used in various dialog boxes that have a filename field Action by User Yes Overwrite the file No Return the focus to the original dialog box without overwriting the file Q0201005 Message Save all the files currently being edited Explanation This message appears to ask the user whether to save files being edited Action by User Yes Save all the files currently being edited No Cancel action Q0201006 Message If the registered files opened by some external tools exit that tools To continue the processing press OK Explanation This message appears to ask the user whether to save files being edited by an external tool Action by User Yes Continue the processing No Cancel action Q0201007 Message Xxx may have been changed by another program Are you sure you want to reload the file Explanation This appears when changes have been made to the file edits deletions or renam ing Action by User Yes Reload the file N
125. ct The case when IDE was downloaded via a network the case when you have no access privileges to an account or etc E0200009 Message Failed to launch this product Explanation Starting up the IDE has failed Action by User Check that this product has been correctly installed Check that no project files are corrupt E0201001 Message Renaming failed Explanation This error occurs when a rename fails Action by User Make sure you have access privileges to the file before renaming it E0201002 Message Check whether the file or folder has been set to read only Explanation This error occurs when the program fails to save project information Action by User Make sure that the folder or file is not read only E0201003 Message Could not find the file Explanation A file e g source file required for the build was not found E0201004 Message Could not find the folder Explanation This indicates that the copy destination folder was not found when packing Action by User Make sure that the pack destination folder is not read only E0201005 Message Folder creation failed E0201006 Message Reading xxx failed Explanation This error occurs when the program fails to load a file Action by User Check the access privileges to the file E0201007 Message
126. d Action by User Correct the setting when it is illegal E1720037 Message The specified string is invalid Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when an invalid string is specified ztENESAS Page 86 of 152 CS V3 00 00 5 MESSAGES E1720038 Message More than xxx lines cannot be specified Explanation This appears when the maximum number of elements that can be specified in a list has been exceeded Action by User Specify no more than the maximum number of elements E1720039 Message Failed to get the macro definitions of the compiler direct cause Explanation Reference to a macro definition for the compiler has failed Action by User Take appropriate measures in response to direct cause E1720040 Message Failed to set the macro definitions of the compiler direct cause Explanation Setting of a macro definition for the compiler has failed Action by User Take appropriate measures in response to direct cause E1720041 Message Failed to get the compiler package version direct cause Explanation Reference to the version number of the compiler package has failed Action by User Take appropriate measures in response to direct cause E1720100 Message The exception was generated by Python function for CS direct cause Explanation This appears wh
127. d Action by User Perform the download M0821007 Message Failed to analyze cross reference file xxx Explanation This appears when the cross reference information file is corrupt This appears when the cross reference information file could not be loaded Action by User Check the access privileges of the file Make sure that the file is not corrupt M0821008 Message Failed to analyze load module file xxx Explanation This appears when the file could not be downloaded to the debugger for analysis of address information or the like Action by User Execute the build Check the access privileges of the file Make sure that the file is not corrupt M0821009 Message Could not find import file xxx Explanation This appears when the import file specified in the properties does not exist Action by User Make sure that the file exists M0824001 Message Because the RRM function is not effective a part of the result of Analysis Chart panel cannot be displayed Please set to use the RRM function in the property of Access Memory While Running category of Debug Tool Settings category of debug tool Explanation This appears when the RRM function is not enabled in the debug tool settings and the method for acquiring variables is set to real time sampling in the Analysis Chart panel Action by User Enable the RRM function i
128. d Explanation This appears when the application fails to open link directive file generation dialog box Action by User Set correct microcontroller information E0262001 Message Executing source converter failed Explanation This appears when the necessary files could not be created when the source con verter started Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Change for example the location where the project is created and try again ztENESAS Page 44 of 152 CS V3 00 00 E0269001 Message 5 MESSAGES No column to save a file Explanation No columns have been selected for saving when file output has been requested Action by User Select the columns that you wish to save in the Column Chooser dialog box E0269002 Message No row to save a file Explanation No rows have been selected for saving when file output has been requested Action by User Select the rows that you wish to save in the Filter Settings dialog box E0269003 Message Failed to save a file because the number of lines had exceeded the limitation value of Excel Explanation The number of lines has exceeded the limit for an Excel file Action by User Ensure that the number of lines set in the Filter Settings dialog box is no greater than 65535 E0269004 Message Specify the condition here when the
129. d address is empty E1891150 Message Specified channel number is out of its range E1891151 Message Because the performance is being measured the result cannot be acquired E1891152 Message Because the operating frequency is not set the count value cannot be converted E1891200 Message The number of instructions being analyzed has exceeded the maximum number of lines of disassembled code that can be displayed E1891201 Message There is no trace data E1891202 Message There is no trace data in the specified cycle E1891203 Message Failed in the analysis of disassembled code E1891204 Message Failed to get information of the trace cycle E1891300 Message Trigger cable not connected E1891301 Message Temporary file create failure E1891302 Message To transfer settings to the emulator failed E1891304 Message There are too many events E1891308 Message Address range is over E1891309 Message The label is invalid E1891310 Message Address range is over E1891311 Message The settings cannot be changed while the target program is running E1891312 Message Now this event condition is locked by another debugging function E1891313 Message The trace full break settings cannot be changed while the target program is run ning E1
130. dd Bitmap one or both of the active and inactive bitmaps are not set Action by User Specify a bitmap file E1310711 Message Abitmap path is invalid Explanation In the I O panel under Add Bitmap the specified bitmap file is incorrect Action by User Make sure that the file exists and check its attributes E1310720 Message Illegal active voltage s Please input positive integer s Explanation In the I O panel under Analog Button Settings non numeric characters have been entered for the active voltage Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Enter a correct value ztENESAS Page 70 of 152 CS V3 00 00 5 MESSAGES E1310721 Message Illegal inactive voltage Please input a positive integer Explanation In the I O panel under Analog Button Settings non numeric characters have been entered for the inactive voltage Action by User Enter a correct value E1310722 Message The value of active voltage s is over the range Explanation In the I O panel under Analog Button Settings the active voltage is outside the valid range 0 to 65 535 Action by User Enter a correct value E1310723 Message The value of inactive voltage is over the range Explanation In the I O panel under Analog Button Settings the inactive voltage is outside the valid
131. de E1813204 Message The internal clock is halted because the MCU is in the sleep mode E1813207 Message FFWERR_BMCU_DEEPSTANBY E1813208 Message The command is not executable because an internal reset of MCU was generated E1813403 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Failed to connect with the mcu EMLE pin level on the target system does not come to H ztENESAS Page 93 of 152 CS V3 00 00 5 MESSAGES E1813404 Message Failed to connect with the MCU because the emulator could not control the signal for TRSTn pin E1813405 Message Failed to connect with the MCU because the emulator could not control the signal for TMS pin E1813406 Message Failed to connect with the mcu The pin to specify user boot is not controllable E1813407 Message Failed to connect with the mcu MD pin is not controllable E1813500 Message Specified baud rate is smaller than its limit E1813501 Message Specified baud rate is larger than its limit E1813502 Message Internal error FFWERR_ASCI_COMERR E1813503 Message Internal error FFWERR_ASCI_COMOV E1813504 Message A serial communication error Framing error E1813505 Message A serial communication error Overrun error E1813506 Message A serial communication error Parity error E1813507 Message A serial communication error Sending timeout error E1813508
132. destination address from the specified location In this case it is not possible to jump from here Make sure that the debugging tool is connected E0220004 Message Displaying the local variable at this time failed Explanation This message appears when an error occurs executing the Show Current Local Variables menu command Action by User Make sure that the debugging tool is connected E0220005 Message Could not move Explanation This error occurs when the move command fails from the Disassembly panel Action by User This error occurs when the program fails to resolve the move destination address E0220006 Message Deletion failed Explanation This error occurs when a deletion operation fails Action by User Make sure you have access privileges to the file before deleting it E0220007 Message Clearance failed Explanation This error occurs when a clear operation fails Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Follow the instructions in the message to remedy the problem ztENESAS Page 40 of 152 CS V3 00 00 E0220008 Message 5 MESSAGES Executing xxx failed Explanation This error occurs when an execution operation fails Action by User Follow the instructions in the message to remedy the problem E0222001 Message The location where the projec
133. different from its mapped bus size W1216412 Message Software break can not be set on this area W1220491 Message Specified device file does not relocate internal RAM W1220494 Message No tag data which it was going to refer to device file W1228688 Message No source information exists W1228689 Message Unknown result of step execution W1245086 Message No debug information not compiled by the method of generating debug informa tion W1245110 Message Out of variable region W1245122 Message Symbol module is not initialized W1245877 Message Too long symbol name W1249175 Message Symbol information is duplicated please reset symbols W1249178 Message BSS area is assigned to non mapped area W1249180 Message Programmable IOR address mismatch R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 146 of 152 CS V3 00 00 W1249181 Message 5 MESSAGES Selected load module different from kind Chip was loaded W1790000 Message The timer overflow W1790001 Message The timer function is not supported W1810204 Message USB bus power volage is low Action by User Change the host machine W1811110 Message MDE register was modified W1811111 Message UB code was modified W1811112 Message MDE register and UB code are modified W1811115 Message Started up with hot plug in bu
134. direct cause E1710046 Message No trace data E1710047 Message Failed to write in direct cause E1710048 Message Failed to reset direct cause E1710049 Message Failed to execute the procedure step direct cause E1710050 Message Could not find the specified file E1710051 Message Please input the script file name E1710052 Message Failed to return out direct cause E1710053 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message NoSymbol and SymbolOnly cannot be specified simultaneously 2tENESAS Page 74 of 152 CS V3 00 00 E1710054 Message 5 MESSAGES Failed to execute the go command E1710055 Message The coverage function is not supported in this debugger E1710056 Message The coverage function is not supported in this environment E1710057 Message The error occurred by referring to the coverage function direct cause error message E1710058 Message The function is not supported in this debugger E1710059 Message The function is not supported in this environment E1710060 Message The error occurred by referring to the function function direct cause error message E1710061 Message The open break function is not supported in this debugger E1710062 Message The open break function is not supported in this environment
135. e appears when non hexadecimal values are entered in the initial data textbox in the Memory Initialize dialog box Action by User Enter initial values in the input box in hexadecimal format W0245001 Message The search data cannot be omitted Explanation When a search data input box of the Memory Search dialog box was in the state of the blank and a OK button was clicked it s shown to an error service provider Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Input a character string to a search data input box ztENESAS Page 135 of 152 CS V3 00 00 5 MESSAGES W0245002 Message The search data format is invalid Specify with yyy of xxx Explanation This appears in an error services provider when the format specified in the Memory Search dialog box differs from the notation or size shown in the Memory panel Action by User Specify the data format displayed in the Memory panel in the search data W0245003_ Message Up to xxx bytes of data can be searched at one time Explanation This appears in an error services provider when the specified size of data in the Memory Search dialog box exceeds the number of specified bytes Action by User Specify data of the size less than the number of specified bytes W0245004 Message An invalid character string has been entered Enter a character
136. e device ztENESAS Page 56 of 152 CS V3 00 00 E1203127 Message 5 MESSAGES The voltage is too low to operate flash programming E1203128 Message Extended monitor area is not blank E1203129 Message Real time RAM monitoring failed E1203130 Message Writing the DataFlash area is not supported E1203131 Message Can not write the DataFlash memory because of it is not in the DataFlash environ ment E1203132 Message External flash memory information is not set E1203133 Message Can not erase external flash memory E1203134 Message Can not write external flash memory E1203135 Message The intended value is not permitted for on chip debugging E1203136 Message Status of effective event conditions cannot be changed E1203137 Message Coverage test is being executed E1203138 Message Monitor has failed in shift in the debugging mode Please reset the CPU E1203139 Message Connection of emulator cannot be performed E1203140 Message Coverage test is being executed E1203141 Message Inside of Power off reset emulation cannot carry out program execution E1203142 Message Change of Internal ROM size or Internal RAM size or RAM monitor or DMM is not valid during Flash Self Emulation E1203143 Message Emulation of ROM correction has already been
137. e file E1221253 Message Illegal database file format E1221254 Message Database information has been already initialized E1221255 Message Database information does not exist E1221256 Message Can not open specified database file E1221257 Message Specified database file is illegal version E1224576 Message Current function does not exist E1224577 Message Illegal symbol name E1224578 Message Illegal condition E1224579 Message Illegal function name E1224580 Message Overflowed output buffer size E1224581 Message Illegal expression E1228672 Message Illegal mode E1228673 Message User program is running E1228674 Message User program has been stopped E1228675 Message Trace enabled E1228676 Message Trace memory is not set E1228677 Message Function return address does not exist can not do step execution E1228690 Message Not enough memory E1228926 Message Bus hold error E1228927 Message Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the
138. e for printing Depending on the size of the source file this may take time and use a large amount of memory Explanation This appears when printing was performed in mixed view mode M2000002 Message Generating full disassembled file for print preview Depending on the size of the source file this may take time and use a large amount of memory Explanation This appears when print preview was selected in mixed view mode M2000003 Message Generating a print image for this file Please wait Explanation This appears when an image is generated in the print and print preview functions M2000004 Message Generating full disassembled file for saving source mixed mode Depending on the size of the source file this may take time and use a large amount of memory Explanation This message appears when the mixed display of the source file is being saved M2000005 Message Selection has collapsed because used up memory Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This message appears when the selection of a string in the Editor panel was can celed due to a shortage of memory ztENESAS Page 111 of 152 CS V3 00 00 5 MESSAGES 5 4 Choices Table 5 4 Choices Q0120000 Message The following updates must be installed to install the updates you selected Do you want to select these updates Q0120004 Message The following
139. ecause could not open an editor panel Explanation This message appears when no more Editor panels can be opened while the pro gram is not running Action by User Up to 100 Editor panels can be opened Close unnecessary panels before opening new panels Check that you have permission to open source files M0238001 Message Creates some files for error reporting on the desktop Please attach these files when report the error Explanation This message appears in response to clicking on the Recode Screen button in the Message dialog box M0244001 Message Initializing memory Explanation This message appears in the Progress Status dialog box when initializing memory from the Memory Initialize dialog box M0249001 Message The specified value does not exist from the present location to the xxx of a tree Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when moving in a search for values in the SFR panel IOR panel and the specified value is not found in the direction of movement ztENESAS Page 105 of 152 CS V3 00 00 M0251001 Message 5 MESSAGES Getting trace data Explanation This appears when a large amount of time is required to get data in the Trace panel M0269001 Message Generating memory mapping Press ESC key or Cancel button to abort processing Explanation
140. ecified stub event has not been registered E1200781 Message Timer is running E1200782 Message Memory copy area is overlapped E1200783 Message Trace has been already set E1200784 Message Event condition is not set E1200785 Message Too many valid timer event conditions R20UT3099EJ0100 Rev 1 00 ztENESAS Page 53 of 152 Aug 01 2014 CS V3 00 00 E1200786 Message 5 MESSAGES Specified timer event is not set E1200787 Message Illegal map range E1200788 Message Only trace delay mode can set with delay trigger E1200789 Message Delay trigger cannot set without trace delay mode E1200790 Message Overflowed the number of mapping E1200928 Message Target is not turned on E1200929 Message Step execution is being done E1200930 Message Timer and Tracer are running E1200931 Message Event link and BRS events are mixed E1200976 Message Back trace is being executed E1200977 Message Back trace is being stopped E1200978 Message Back trace execution point overrun oldest frame E1200979 Message Register status or Memory status cannot be set up other than Phase of event link E1200980 Message No back trace information exists E1200981 Message Last command can not be backstepped E1201024 Message Illegal conditio
141. eeded while adding files to the project Action by User Reduce the number of registered files by removing unneeded files from the project E0202066 Message Because the format version is different this product cannot read this project file Explanation Tried to read the project file to which it isn t compatible Action by User Confirm whether it s identical with tool version made created project file When it s necessary update integrated development environment framework and a plug in E0202067 Message Saving hex output options failed Explanation Failed to save hex output options to the project file Action by User Check the version of the project file E0202068 Message Restoring hex output options failed Explanation Failed to restore hex output options from the project file Action by User Check the version of the project file E0202069 Message Failed to import build options Action by User Check if the project file specified for import is corrupt or if the project cannot be imported E0202070 Message Specified project file is not supported for the build tool Explanation The project file specified for import in the build options is not supported Action by User Make sure that the build tool and project type are correct E0202071 Message Upper bounds of the number of subprojec
142. een reached Please consider deleting some existing bookmarks Explanation This message appears when the number of registered bookmarks has exceeded the maximum value E2000010 Message Could not set break event Explanation This message appears in case of failure to set a breakpoint by using the Editor panel E2000011 Message Could not remove break event Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This message appears in case of failure to remove a breakpoint by using the Editor panel ztENESAS Page 101 of 152 CS V3 00 00 E2000012 Message 5 MESSAGES Searching or replacing failed Explanation This message appears when a search or replacement has failed E2000013 Message The specified file xxx could not be opened Explanation This message appears in case of failure to open a file by using the Editor panel E2000014 Message Could not create a temporary file Explanation This message appears in case of failure to create a temporary file at the time a file was saved E2200001 Message file not found Explanation This appears when the device file specified by the df option does not exist E2200002 Message cannot open file Explanation This appears when the device file specified by the df option could not be opened E2200003 Message device file is not
143. eference options from the project file Action by User Check the version of the project file E0202035 Message Saving individual compile options failed Explanation Failed to save individual compile options to the project file Action by User Check the version of the project file E0202036 Message Restoring individual compile options failed Explanation Failed to restore individual compile options from the project file Action by User Check the version of the project file E0202037 Message Saving individual assemble options failed Explanation Failed to save individual assembly options to the project file Action by User Check the version of the project file E0202038 Message Restoring individual assemble options failed Explanation Failed to restore individual assembly options from the project file Action by User Check the version of the project file E0202039 Message Project manipulation is prohibited Explanation This error occurs when trying to change the construction of the project when proj ect actions are prohibited in build Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Wait until the current process completes ztENESAS Page 28 of 152 CS V3 00 00 E0202040 Message 5 MESSAGES Project manipulation could not be enabled Explanati
144. elect the voltage E1891719 Message Please select the MCU group and device name E1891721 Message The power voltage has exceeded 5 9V Please check the user system setting E1891722 Message Updating of the firmware has been completed Click on the OK button If you are using the E1 disconnect the USB interface cable and then re connect it If you are using the E20 turn off the power for the emulator and then turn it on again E1891723 Message Invalid LEVEL EML status Unable to download the firmware E1891724 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Input clock was rounded down to xx ztENESAS Page 99 of 152 CS V3 00 00 E1891725 Message 5 MESSAGES Starting up with the hot plug in failed because the user system has already con nected to the emulator User program was reset E1891726 Message Failed to connect with the mcu Please confirm the state of the MD pin and the pin to specify user boot on the target system E1891727 Message The specified endian is not corresponding to the endian of CPU E1891728 Message Please enter the value of Vcc supplied actually to the user target board Action by User Enter the Vcc value E1891800 Message The endian defined in the USD file is not corresponding to the endian of the CPU E1891801 Message It is not possible to allocate it to other tha
145. en an unexpected exception occurs in the called function E1720101 Message Failed to close the project direct cause Explanation This appears when closing the project fails E1720102 Message Failed to open the project direct cause Explanation This appears when opening the project fails E1720103 Message Failed to add the project direct cause Explanation This appears when adding a file to the project fails E1720104 Message Failed to remove the project direct cause Explanation This appears when removing a file from the project fails E1720105 Message Xxx could not be found Explanation This appears when the specified file was not found in the project E1720106 Message Failed to change the active project direct cause Explanation This appears when changing the active project fails E1720107 Message The specified project was not found Explanation This appears when the specified project is not found E1720108 Message The specified project is the active project Explanation This appears when the specified project is set as the active project R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 87 of 152 CS V3 00 00 E1720109 Message 5 MESSAGES Failed to obtain project information direct cause Explanation This appears when obtaining the project information fails E1720110 Message The specified file does not exist Explanation This ap
146. enabled E1203144 Message Flash programming is not permitted by the debugger setting E1203149 Message Security unlocking failed E1203152 Message Flash memory cannot be read or written to because the MCU is in the flash pro gramming mode P E mode E1203153 Message Flash memory cannot be read or written to because the FCU firmware resource has been selected for the FCU firmware area E1203168 Message Event before execution cannot be set up other than break conditions E1203169 Message Can not register event numbers which can not be used for hardware break E1203170 Message Event numbers reserved for hardware breaks can not be used E1203171 Message Event link conditions cannot set E1203172 Message Too many ROM emulation RAM areas E1203175 Message Writing to two flash memory blocks is prohibited E1203176 Message Cannot emulate of ROM correction in undefined code E1203177 Message The address outside the DataFlash area was specified E1203178 Message The address outside the external flash memory area was specified E1203184 Message DCU cannot be accessed E1203185 Message Reset cannot be performed E1203186 Message Monitor memory cannot be accessed E1203187 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Monitor execution can
147. er Please try again after waiting for a while E0113008 Message The server response was not a valid Please retry the operation after a while Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0113009 Message An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0113010 Message An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0113011 Message A connection with the proxy server could not be established Cannot find server or DNS error Action by User Make sure that you can display ordinary and secure Internet sites sites starting with https in Internet Explorer Contact your network administrator if you cannot E0113012 Message The server response was not a valid Please retry the operation after a while Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0113013 Message An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0113014 Message
148. es Action by User OK An image is created Cancel Creation of an image is canceled Q2000007 Message Xxx file size is more than 24MB In the case of a large file the processing of syntax coloring takes long time Disable the processing When syntax coloring is disabled code outlining and smart editing also will be dis abled Hereafter this selection is applied to larger files than 24MB Explanation This message appears to allow you to select whether to disable syntax coloring in a large file because of the time processing for this takes Action by User Yes Syntax coloring code outlining and smart edit function in files larger than 24 Mbytes is disabled No Syntax coloring code outlining and smart edit function is always enabled Q2200001 Message file name is exist overwrite y n Explanation The specified file already exists Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 y The file is overwritten and processing is continued n Cancel action ztENESAS Page 127 of 152 CS V3 00 00 5 5 Warnings Table 5 5 wo0023001 Warnings Message 5 MESSAGES No Tag xxx W0023002 Message Invalid data W0024001 Message No Tag xxx wo0024002 Message Invalid data W0130000 Message Following updates are not displayed because the necessary license
149. ess Status dialog box while a project file is being loaded M0204001 Message Downloading load module Explanation This message appears in the Progress Status dialog box when the load module is being downloaded to the debugger During download the name of the file being downloaded appears in the third line of the message M0204002 Message Connecting to xxx Explanation This message is shown in the Progress Status dialog box when connecting The name of the connected debugging tool appears in xxx M0204003 Message Connecting to xxx Emulator firmware is automatically updated if necessary Do not disconnect USB cable and power supply until connection is completed Explanation This message is shown in the Progress Status dialog box when connecting The name of the connected debugging tool appears in xxx M0204004 Message Preparing Hot Plug in Emulator firmware is automatically updated if necessary Do not disconnect USB cable and power supply until connection is completed Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This message is shown in the Progress Status dialog box when preparing Hot Plug in ztENESAS Page 104 of 152 CS V3 00 00 M0206001 Message 5 MESSAGES Searching Explanation This message appears in the Progress Status dialog box when performing a search by specifying In current project
150. external flash ROM is not corresponding OXXXXXXXX OXXXXXXXXX Maker ID XXXX expected value XXXX Device ID XXXX expected value XXXX E1812805 Message Script file for the external flash ROM is not found E1812806 Message The verify error occurred when the writing program was downloaded for external flash ROM E1812807 Message The verify error occurred in the batch file execution before and after the writing pro gram download for external flash ROM E1812900 Message C2E buffer has no data E1813000 Message The command is not executable because the user program is running E1813001 Message The command is not executable because the user program is halted E1813004 Message Not connected to MCU E1813100 Message The command is not executable because the power supply to the MCU is off E1813101 Message The command is not executable because the signal on the reset pin is assert sta tus E1813104 Message User system is not connected E1813105 Message The power supply voltage of the user system has already been supplied E1813106 Message Command is not executable because the MD pin level on the target system is L E1813201 Message The command is not executable because the MCU is in the reset state E1813203 Message The internal clock is halted because the MCU is in the standby mo
151. fied for loading a user model into the configuration file Action by User Specify a user model file E1310181 Message Can t open the usermodel file Explanation Cannot open the specified user model file or there is no MakeUserModel function Action by User Make sure that the file exists check its attributes and make sure that the MakeUserModel function exists E1310200 Message The pin name is invalid Explanation The specified terminal name is incorrect target device does not exist Action by User Specify the terminal name for an existing target device E1310440 Message Programis running Explanation Processing cannot be performed in the timing chart because the program is run ning Action by User Perform the action after halting program execution E1310500 Message Correspondence of loop is not correct Explanation The loop starts and ends do not correctly correspond in the Signal Data editor Action by User Correct the corresponding loop starts and ends R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 69 of 152 CS V3 00 00 E1310501 Message 5 MESSAGES The data number exceededmaximum Explanation The data number line number in the Signal Data editor has exceeded the maxi mum value 1 048 576 Action by User Edit it so that the maximum value is not exceeded E1310502 Message The pin name is invalid Explanation The s
152. fied has a start address that is larger than the end address Action by User Specify a start address that is less than or equal to than the end address W0603018 Message Enter a value in the range of xxx to yyy Explanation This message appears when a value greater than the address space of the debug ging tool is specified in an area for an address or symbol range Action by User Specify an address range that fits in the address space of the debugging tool W0603019 Message The specified symbol does not exist Explanation This message appears when a nonexistent symbol is specified in an area for an address or symbol range Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify an existing symbol ztENESAS Page 144 of 152 CS V3 00 00 W0603020 Message 5 MESSAGES The address cannot be omitted Explanation This message appears when an area for an address symbol is left blank and blank entries are not allowed Action by User Specify an address symbol or address expression W0603021 Message The character string is too long Specify a character string with xxx or fewer char acters Explanation This message appears when a string was specified in a string area that was longer than the maximum length Action by User Specify a string of no more than the maximum number of characters W
153. g the HEW project file The conversion may take several minutes M0293000 Message Compiler name Moved next libraries in Using libraries property XXXXXXXXXXXX Explanation This message appears in the Output panel when the library files being used are to be deleted while Yes Level 3 is selected in the Perform intermodule optimiza tion property of the Optimization Details category on the Compile Options tabbed page M0293001 Message The settings of Constituent Application Projects property are removed because the Microcomputers are different Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when the specified devices differ between associated projects during loading of the projects ztENESAS Page 106 of 152 CS V3 00 00 M0294000 Message 5 MESSAGES CC RL Moved next libraries in Using libraries property Explanation This message appears in the Output panel when library files in use are deleted while Yes Level 3 is selected for the Perform inter module optimization prop erty under the Optimization Details category on the Compile Options tabbed page M0300001 Message The setting of pin No pin number was changed to unused M0409000 Message xxx was generated M0409001 Message The following files were generated M0409002 Message The generating source folder is xxx
154. ge 5 MESSAGES Restoring library options failed Explanation Failed to restore library options from the project file Action by User Check the version of the project file E0202029 Message Saving object convert options failed Explanation Failed to save object conversion options to the project file Action by User Check the version of the project file E0202030 Message Restoring object convert options failed Explanation Failed to restore object conversion options from the project file Action by User Check the version of the project file E0202031 Message Saving compile build setting options failed Explanation Failed to save compile build preference options to the project file Action by User Check the version of the project file E0202032 Message Restoring compile build setting options failed Explanation Failed to restore compile build preference options from the project file Action by User Check the version of the project file E0202033 Message Setting assemble build setting options failed Explanation Failed to restore assembly build preference options from the project file Action by User Check the version of the project file E0202034 Message Restoring assemble build setting options failed Explanation Failed to restore assembly build pr
155. ge Illegal data received E1200263 Message Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1200264 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Failed in reading initialization file expc ini ztENESAS Page 51 of 152 CS V3 00 00 5 MESSAGES E1200265 Message Can not communicate with Emulator Please terminate the debugger and check the power of Emulator or the connection of cable then restart the debugger Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of
156. ge Jump to interrupt control register failed Explanation This message appears when the interrupt control register jump command from the Function List panel fails Action by User Make sure that the SFR IOR panel can be opened Make sure that the SFR exists E0822001 Message Could not set a break point at the head of function Action by User The debugging tool may not have enough resources Make sure that the number of breaks is within the number that can be set E0822002 Message Jump to function list failed Explanation This appears when a jump command is executed to the Function List panel and the specified location cannot be opened Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Make sure that the specified function is displayed in the Function List ztENESAS Page 50 of 152 CS V3 00 00 E0822003 Message 5 MESSAGES Jump to variable list failed Explanation This appears when a jump command is executed to the Variable List panel and the specified location cannot be opened Action by User Make sure that the specified variable is displayed in the Variable List E0823001 Message Could not set a access break to the variable Action by User The debugging tool may not have enough resources Make sure that the number of breaks is within the number that can be set E0825001 Message Specify
157. ge appears when a line in the display source set in the Edit Text dialog box is longer than the maximum number of characters Action by User Shorten the line that is greater than the maximum length so that it is within the maximum number of characters W0603003 Message More than xxx lines cannot be specified Explanation This message appears when the display source set in the Text Edit dialog box is longer than the maximum number of lines Action by User Make sure that the number of lines is no more than the maximum limit W0603004 Message Specify xxx digits in hexadecimal Explanation This message appears when a string containing characters that cannot be used to represent a base 16 number is entered in a base 16 number field or when the number of digits is not valid Action by User Specify a hexadecimal number with lt valid number of digits gt W0603005 Message This address expression is invalid Check if the expression is correct or if the spell ing of the symbols used in the expression is correct Explanation This message appears when the start address or end address in the Memory Ini tialize dialog box is an invalid address expression W0603006 Message Specify a numerical value Explanation This message appears when a string containing characters that are invalid as num bers was entered in a numeric field Action by Use
158. ge appears when the debug tool encounters an error at the time a timer event is disabled Action by User Solve the problem indicated as direct cause E1710159 Message Address condition is not set Explanation This message appears when no address condition is set for the specified timer event Action by User Set the address E1710160 Message Failed to set the timer event direct cause Explanation This message appears when the debug tool encounters an error at the time a timer event is set Action by User Solve the problem indicated as direct cause E1710161 Message The specified timer event type is illegal direct cause Explanation This message appears when the type condition of the specified timer event is ille gal Action by User Specify a correct type E1710162 Message Failed to delete the specified timer event direct cause Explanation This message appears when the debugger has failed to delete a timer event Action by User Solve the problem indicated as direct cause E1710163 Message Failed to enable the timer event direct cause Explanation This message appears when the debugger has failed to enable a timer event Action by User Solve the problem indicated as direct cause E1710164 Message Failed to disable the timer event direct cause
159. get function end point ztENESAS Page 110 of 152 CS V3 00 00 M0827002 Message 5 MESSAGES Corresponding function to the search condition was not found Explanation This message appears when all functions have been searched in the whole view and no function meeting the specified search conditions has been found M0827003 Message Corresponding function variable to the search condition was not found Explanation This message appears when all functions variables have been searched in the detailed view and no function variable meeting the specified search conditions has been found M0828001 Message A node that contains the specified text does not exist from the present location to the xxx of a tree Explanation This appears when moving in the class view and a node with the specified text is not found in the direction of movement start or end is displayed in xxx M0829001 Message There is no file to analyze Explanation This message appears when no checkboxes are selected although it is necessary to select files to be analyzed Action by User Select at least one file that you wish to be analyzed M1790000 Message Already connected to a debug tool Explanation This message is shown when executing the connect command in the state con nected with a debug tool M2000001 Message Generating full disassembled fil
160. gger Explanation This appears when a debugger support to only an event of the execution type of the section timer when setting an event of an access type E1710182 Message The specified processor element was not found Explanation This appears when the specified PE number is illegal Action by User Specify an existing PE number E1710183 Message Combination break is not supported Explanation A combination break condition has been set but the emulator or simulator in use does not support combination breaks Action by User Be sure to use an emulator or simulator that supports combination breaks E1710184 Message Failed to set the action event item direct cause Explanation This message appears when the debugger has failed to set the action event Action by User Take appropriate measures in response to direct cause E1710185 Message Failed to delete the action event direct cause Explanation This message appears when the debugger has failed to delete the action event Action by User Take appropriate measures in response to direct cause E1710186 Message Failed to delete the specified action event direct cause Explanation This message appears when the debugger has failed to delete the action event Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Take app
161. he setting of the trace There is a possibility that a part of the result of Analysis panels is not displayed Explanation This appears when the trace data being analyzed does not contain read or write data Action by User Check the trace output settings M0812005 Message Variable information was not found xxx Explanation This appears during moving analysis of values in a trace when a matching line cannot be found in the variable list data Action by User Make sure that the variable name exists If there is a variable with this name add the scope and specify it so that a unique line can be identified M0820001 Message Could not be analyzed correctly See the Program Analyzer tab in the Output panel Explanation A message was displayed on the Output panel to indicate that a problem occurred during trace analysis M0821001 Message Could not import the information from a file xxx Explanation This message appears when an import file specified in the properties could not be loaded Action by User Make sure that the file exists Check the access privileges of the file Make sure that the file is not corrupt M0821002 Message Could not find cross reference file xxx Explanation This message appears when a cross reference file was not found the file will be excluded from analysis Action by User Execute the bu
162. he debugging tool is connected E0207002 Message The specified range includes the memory area that cannot be written Explanation This message appears when the OK button is clicked in the Memory Initialize dia log box Action by User Check whether to contain the memory area that cannot be written within the speci fied area E0207003 Message Failed to write the Flash Options to a debugger Explanation This error occurs when the Write button is clicked in the Flash Options Setting dialog box Action by User Make sure that there are no problems with the debug tool connection or settings E0207004 Message Failed to read the Flash Options from a debugger Explanation This occurs when the Load button is clicked in the Flash Options Setting dialog box Action by User Make sure that there are no problems with the debugging tool connection or set tings E0208001 Message Could not remove break event Explanation This error occurs when a breakpoint could not be removed from the Editor or Dis assemble panel Action by User Make sure that the debugging tool is connected E0208002 Message Could not set break event Explanation This error occurs when a breakpoint could not be set on the Editor or Disassemble panel Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 The setting
163. he source and destination project folders are different and source conversion is to be performed then you will be asked to con firm whether to perform the operation Action by User Yes Change the creating folder to original project folder proceed to source conversion No Without changing the creating folder proceed to source conversion Cancel Return to the Create Project dialog box and do not proceed to source conversion Q0268001 Message Open the CubeSuite project without changing the settings If you select No open a dialog to change other device or other compiler Explanation This appears when an old CubeSuite product cspj is specified in Open Proj ect Action by User Yes The cspj is opened as if it were a mtpj file No The Project Conversion Settings dialog box opens Specify the device project name and other properties for conversion Cancel The message dialog box closes and the opening of the CubeSuite project is can celled R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 120 of 152 CS V3 00 00 5 MESSAGES Q0291001 Message Do you change a file extension Explanation RH850 RX This message appears when Type of output file property in Output category in Link Options tab will change the file extension of the output file RL78 This message appears when Hex file format property in Hex Format cat egory in Hex Output Op
164. her condi tions E1811413 Message The specified function is not supported for this mcu E1811600 Message The number of software breakpoints has exceeded the maximum value 256 E1811601 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 No software breakpoint has been set 2tENESAS Page 91 of 152 CS V3 00 00 E1811602 Message 5 MESSAGES Software breakpoints cannot be set in the selected area E1811606 Message No software breakpoints can be set in the on chip ROM area during execution of the user program E1811608 Message No software break points can be set in the on chip ROM area during debugging CPU re write mode E1811613 Message Failed to halt the program because the program was being reset E1811700 Message Address areas specified for RAM monitoring overlap E1811702 Message The RAM monitoring block to which an address area has been assigned is dis abled E1811703 Message RAM monitor function is not supported now E1811902 Message Tracing is in progress E1811903 Message There is no trace data E1811910 Message The specified trace mode is not corresponding to the current pin count E1811911 Message The specified address range for ROM spaces is not correct E1811912 Message The address range for window trace is not correct E1811913
165. hin the appropriate range E1310902 Message Illegal data bit length Explanation The data bit length set in the Format Settings dialog box UART or Format Set tings dialog box CSI is outside the valid range integral value of 32 or lower Action by User Specify an integral value in the valid range R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 71 of 152 CS V3 00 00 E1319999 Message 5 MESSAGES The internal error occurred Explanation An internal error has occurred Action by User Please contact your vendor or your Renesas Electronics overseas representative E1700000 Message Failed to initialize the Python Console Action by User Reinstall CS E1700001 Message Failed to save the content that display on the Python Console Action by User Check the save destination of the file E1700010 Message Failed to start the Python Console Action by User Restart CS If this does not resolve the problem reinstall CS E1700011 Message Failed to set font and color of the Python Console Action by User Restart CS E1700100 Message Failed to parse the input string E1700200 Message Failed to display the history E1700201 Message Failed to add the history E1700202 Message Failed to get the history E1700203 Message Failed to c
166. id Explanation This message appears when the specified MicomType is invalid Action by User Specify a valid MicomType E1720127 Message Compiler is not supported Explanation This message appears when the compiler does not support the specified Micom Type or no applicable compilers were found even though Auto had been speci fied E1720128 Message Failed to create the project direct cause Explanation This message appears in case of failure to create a project Action by User Solve the problem displayed as direct cause E1720129 Message The specified project already exists Explanation This message appears when the specified project is already exists Action by User Delete the existing project or specify another path E1720130 Message Program Analyzer Plug in is not loaded Explanation This appears when the Program Analyzer Plug in is not loaded Action by User Enable the Program Analyzer Plug in in the Plug in Manager dialog box E1730000 Message Error Occurred during the execution Explanation This appears when you specified True to generate exceptions and an exception occurred when executing Python code or a Python script Action by User Execute correct code and scripts E1730001 Message Failed to compile the script Explanation This appears
167. ild after setting Enable static analysis information property to Yes M0821003 Message No cross reference information in file xxx Explanation This message appears when the assembler listing file was output but the cross ref erence information was not output in a project for an RL78 Action by User Execute the build after setting Enable static analysis information property to Yes M0821004 Message Source file has been updated Please build to update cross reference files Explanation This appears when updating the Functions List Variables List panel and the source file is newer than the cross reference information Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Execute the build after setting Enable static analysis information property to Yes ztENESAS Page 108 of 152 CS V3 00 00 M0821005 Message 5 MESSAGES The load module file has not been updated Please build to update the load module file Explanation This appears when updating the Functions List Variables List panel and rebuilding could change the load module Action by User Execute the build M0821006 Message The load module file has been updated Please download the load module file Explanation This appears when updating the Functions List Variables List panel and the cur rent file is newer than the load module file being downloade
168. iled to start the trace direct cause Explanation This appears on failure to stop tracing during execution E1710152 Message Cannot stop the trace Explanation This appears on failure to stop tracing during execution E1710153 Message Failed to get the running state Action by User Connect the debugging tool E1710154 Message Failed to get connection status Action by User Connect the debugging tool E1710155 Message Failed to delete the timer event direct cause Explanation This message appears in case of failure to delete a timer event Action by User Solve the problem indicated as direct cause E1710156 Message The specified timer event was not found Explanation This message appears when the specified timer event does not exist Action by User Specify the number of a timer event that does exist E1710157 Message Failed to enable the specified timer event direct cause Explanation This message appears when the debug tool encounters an error at the time a timer event is enabled Action by User Solve the problem indicated as direct cause R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 79 of 152 CS V3 00 00 E1710158 Message 5 MESSAGES Failed to disable the specified timer event direct cause Explanation This messa
169. ilure to close a project E1720120 Message Failed to open the project Explanation This message appears in case of failure to open a project E1720121 Message The specified project file is open Explanation This message appears when the specified project is already open Action by User Specify a different project E1720122 Message Please enter the file specification string all Explanation This message appears when the specified filename was not a string E1720123 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message File could not be found Explanation This message appears when the File category was not found in the project ztENESAS Page 88 of 152 CS V3 00 00 E1720124 Message 5 MESSAGES Please enter the category name is in the character from 1 to 200 Explanation This message appears when the category name is blank or null or has a number of characters outside the range from 1 to 200 Action by User Ensure that the category name consists of 1 to 200 characters E1720125 Message Device information specified was not found direct cause Explanation This message appears when the specified device information was not found for the specified MicomType Action by User Specify device information that does exist E1720126 Message MicomType specified is inval
170. in the upper and lower limits the graph for the target channel is not drawn although horizontal scrolling is performed from the start to the end points One or more channel numbers delimited by commas to which the message applies are shown as xxx Action by User Check Value per grid Val Div or the offset value in the properties of the analysis tool M0824007 Message RRM lost or buffer overflow has occurred during data sampling Explanation This message appears when a value is lost in the case of the normal RRM func tion or a buffer overflows in the dedicated data collection mode for Smart Analog devices during data acquisition by real time sampling If a value has been registered as a target of a graph without a scope having been specified the value is handled as lost because the value cannot be acquired if it is beyond the scope due to the location indicated by the PC position at the time of sampling Depending on the structure of the user program if a static variable in a function has been registered as a target of a graph without specifying a scope a lost value will be likely Action by User If overflows are frequent do not run applications other than CS M0824008 Message The auto adjustment function was turned off Explanation This message appears to notify that auto adjustment is disabled when the value of any of the following properties is manually changed
171. ion informa tion file in the Output category on the Link option tab Explanation This appears when choosing the option which linked W0290010 Message The Uses floating point operation instructions property is changed to Depends on the CPU type option Explanation This appears when choosing the option which linked W0290011 Message Use only the following characters in the field A Z a z0 9 _ Explanation This message appears when invalid characters have been detected in the field where a section name is specified Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Enter a valid section name 7tENESAS Page 138 of 152 CS V3 00 00 W0290012 Message 5 MESSAGES Please enter an integer between 0 and xxx Explanation This message appears when an out of bounds value is entered into an area for specifying an address W0290013 Message Use only the following characters in the field A Z a z 0 9 _ Explanation This message appears when invalid characters have been detected in the field where a section name is specified Action by User Enter a valid section name W0291001 Message The format of section or address is invalid Explanation This message appears when a string with invalid format was entered when input ting a character string in Specify a section start address property in Sectio
172. ions for all build modes Explanation This appears when the Build simultaneously property on the Common Options tabbed page is changed from Yes to No Action by User Yes The compiler options are copied to all build mode No The compiler options are only copied to the current build mode Cancel Cancel action Q0203004 Message It may not be built properly because a circular reference exists Continue the processing Explanation This message appears when there is a circular reference between projects Action by User Yes Execute Build Clean Cancel Cancel Build Clean R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 116 of 152 CS V3 00 00 Q0203005 Message 5 MESSAGES Are you sure you want to set the current compile options to the individual assemble options for all build modes If No is selected copy the current build mode options only Explanation This message appears when individual assemble options are specified with simultaneous build enabled Action by User Yes The individual compiler options are set for all build mode No The compiler options are only copied to the current build mode Cancel Cancel action Q0204001 Message Hot Plug in is prepared Connect the debug target to a PC and click OK Explanation This message appears while waiting for the connection of a hot plug in Action
173. is not supported E1245097 Message Illegal address E1245098 Message Can not communicate with Emulator Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1245099 Message Can not stack trace with current PC value E1245100 Message Too many blocks for one function E1245101 Message Illegal argument E1245102 Message The file does not exist in the SOURCE PATH E1245103 Message Information has been deleted because of optimization E1245104 Message Monitor timed out E1245105 Message Already set in memory E1245106 Message Out of scope E1245107 Message LP is not stored R20UT3099EJ0100 Rev 1 00 ztENESAS Page 66 of 152 Aug 01 2014 CS V3 00 00 5 MESSAGES E1245108 Message Return execution from presen
174. l then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1216384 Message Can not delete specified event E1216385 Message Illegal table number E1216386 Message Illegal start address E1216387 Message Illegal end address E1216388 Message Illegal status E1216389 Message Illegal data E1216390 Message Specified event number has been already used E1216391 Message Too many same events are registered E1216392 Message Specified event has not been registered E1216393 Message Illegal data size E1216394 Message Illegal mode E1216395 Message Setting value is inaccurate E1216396 Message Event link conditions cannot be used for section trace conditions E1216397 Message Too many identical events are registered gt 32767 E1216398 Message Specified event condition does not exist E1216399 Message R
175. l the property values on this sheet are reset to the default values OK Explanation The program asks for user confirmation when the Property gt Reset All to Default command is executed Action by User Yes The property values are reset to the default values No Cancel action Q0232001 Message Delete build mode xxx Explanation This message appears when attempting to delete a build mode Action by User OK Delete build mode xxx Cancel Cancel action Q0232002 Message Requires saving the current project to enable to restore the current project status after changing the microcontroller Continue saving and processing Explanation This appears when the microcontroller is changed Action by User OK Continue saving and processing Cancel Cancel action Q0261001 Message The section has been set the specified segment Also delete the section Explanation This appears when deleting a segment and the segment to be deleted held one or more sections Action by User Yes Delete the entire section No Cancel delete Q0261002 Message The memory space has been set the specified memory area Also delete the mem ory area and segment that includes Explanation This message appears when a memory area is included in the memory space that is to be deleted Action by User R20
176. le Action by User UThere may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis connected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect R20UT3099EJ0100 Rev 1 00 ztENESAS Page 52 of 152 Aug 01 2014 CS V3 00 00 5 MESSAGES E1200433 Message Can not communicate with monitor program Please terminate the debugger and check the power of CPU board or the connection of cable then restart the debug ger Action by User There may have been an error in the USB communication e g power or cable disconnected or the IECUBE may be malfunctioning IECUBE Select Debug gt Disconnect from Debug Tool then turn off the power to the IECUBE After checking the connection turn the power of the IECUBE back on then select Debug gt Connect to Debug Tool to reconnect There may have been an error in the USB connection e g power or cable dis co
177. lear the history E1700210 Message The specified argument is invalid Please specify only one argument Explanation This appears when argument is specified in case of all except for 1 by an argument of the CUI mode Action by User Specify only one argument E1700300 Message This problem may occur if it fails to compile the script file Explanation This message appears in case of failure to compile a script file Action by User Correct the script file E1700301 Message Failed to run the script file direct cause Explanation This message appears in case of failure to execute a script file Action by User Solve the problem displayed as direct cause E1700400 Message Failed to write to the Output panel direct cause Explanation This message appears in case of failure to output a message to the Output panel E1700401 Message Failed to get the Output panel contents direct cause Explanation This appears when acquisition of the contents displayed in the Output panel failed Action by User Solve the problem displayed as direct cause E1710000 Message The exception was generated by Python function for CS direct cause E1710001 Message The debugger is not connected Please connect it with the debugger Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014
178. ll the latest service packs and security updates for this product using Windows Update and Microsoft Upadate Stop the installation Explanation This appears when the installation of a required environment fails but when it s necessary to be a restart by the installation which succeeded E0180000 Message This license key is invalid E0180001 Message XXXXXX This license key is already registered E0182000 Message Could not write the license information to xxx E0190000 Message Failed to start License Manager Action by User Please reinstall the CS E0190001 Message Failed to start License Manager Can not find the folder to store the license information Action by User Please reinstall the CS E0200001 Message A critical error occurred Explanation Appears when a fatal error has occurred Action by User Please update this product Please install runtime components of Visual C 2010 x86 SP1 Libraries Please contact your vendor or your Renesas Electronics overseas representative E0200002 Message Launching program program name failed Explanation This appears when the IDE fails to launch a Windows program Action by User Check that the program exists and the name you have specified was that of an executable application E0200003 Message Could not open a file with Explorer
179. ller couldn t be started right C0190000 Message Specified device is invalid C0190001 Message Xxx is empty C0190002 Message Xxx is too large C0190003 Message Xxx is too small C0600000 Message Internal error C0600001 Message Illegal argument xxx yyy C0600002 Message Illegal argument xxx nullptr C0600003 Message It has already registered C0600004 Message It is not registered C0602000 Message Already connected C0602001 Message Already disconnected C0602002 Message A device file is non setting C0602003 Message Unhandled exception occurred C0602100 Message Please check connection with the target board C0602101 Message Please check connection with the target board and power on it C0602102 Message Please check connection of the exchange adapter C0602103 Message Please disconnect the target board C0602104 Message Please power off the target board and disconnect it C0602200 Message Incorrect ID Code Flash memory was erased C0602201 Message Disabled ID Code Flash memory was erased C0602202 Message Incorrect ID Code C1700000 Message Failed to execute the callback event ID xxx Action by User Restart CS C1700001 Message Failed to execute the hook event ID xxx Action by User Restart CS R20UT3099EJ0100 Rev 1 00 ztENESAS Page 10 of 152 Aug 01 2014 CS V3 00 00 C1700002 Message Failed to execute the code 5 MESSAGES Action by User
180. m Please check the connection between the emulator and the user system E1891702 Message The power supply to a user system was detected Please change the setting for the power supply from the emulator E1891703 Message Invalid voltage setting Please check the power supply setting E1891704 Message Power on the user system or please change the setting for the power supply from the emulator E1891705 Message Includes invalid value or symbol E1891706 Message Please enter the code within xx characters E1891707 Message Please confirm that the emulator is not connected to the user system E1891708 Message Connect the emulator with the user system E1891710 Message The loaded emulator firmware does not correspond to the MCU Update now E1891711 Message The power supply voltage has dropped E1891712 Message This emulator can not supply power to the target Please connect the external power to the target board E1891713 Message The value of the main clock frequency is incorrect E1891714 Message Work ram address is incorrect E1891715 Message Work ram exceeds the internal RAM range E1891716 Message Invalid LEVELO status Unable to download the firmware E1891717 Message The version of LEVELO is not corresponding to the debugger E1891718 Message Please s
181. made for adding the obj lib file Refer to the manual for details Explanation A file with the filename extension obj or lib has been added in a case where the Owhole_program option is set in the build properties of the CC RL Action by User Before using the Owhole_program option of the build properties of the CC RL ensure that there are no references from within external modules to functions and variables in the source files to be compiled W0294002 Message The Optimizes accesses to external variables has been specified Check Output external symbol allocation information file in the Optimization Details category on the Link option tab Explanation The Optimize access to external variables option needs to be used in combination with the Output external symbol allocation information file option W0294003 Message The specification of Optimizes accesses to external variables has been canceled in all files in the project Uncheck Output external symbol allocation information file in the Optimization Details category on the Link option tab Explanation Cancelling the Optimize access to external variables option also requires cancel ling of the Output external symbol allocation information file option W0294004 Message The file name is invalid The characters lt gt cannot be used Explanation The filename contains invalid charac
182. mal Explanation A hexadecimal number specifying an area includes characters that cannot be used to represent a hexadecimal number Action by User Specify numeric characters as base 16 W0205016 Message Specify in decimal or hexadecimal Explanation A decimal hexadecimal number specifying an area includes characters that cannot be used to represent a decimal hexadecimal number Action by User Specify a valid string of numeric characters in base 10 or base 16 W0205017 Message Enter a value smaller than the end address for the start address Explanation This message appears when an area in which an address or symbol range is spec ified has a start address that is larger than the end address Action by User Specify an end address that is larger than the start address W0205018 Message Enter a value in the range of xxx to yyy Explanation This message appears when an area in which an address or symbol range is spec ified has a value greater than the address space of the debugging tool Action by User Specify an address range that fits in the address space of the debugging tool W0205020 Message The address cannot be omitted Explanation This message appears when an area for an address symbol is left blank and blank entries are not allowed Action by User Specify an address symbol or address expression
183. mode because USB boot codes are written at the UB codes area in the internal flash ROM Action by User Start CS in single chip mode and remove the UB code area R20UT3099EJ0100 Rev 1 00 ztENESAS Page 90 of 152 Aug 01 2014 CS V3 00 00 E1811125 Message 5 MESSAGES Failed to connect with the mcu The mcu did not permit to be connected with the emulator E1811300 Message Verification error E1811301 Message Programming of the on chip ROM area is not available during execution of the user program E1811303 Message Unidentified instruction has been detected E1811304 Message Access to the data flash ROM is not available during execution of the user pro gram E1811307 Message Because the access violation etc to on chip ROM area are generated the flash rewriting cannot be executed E1811308 Message The access violation to on chip ROM was detected and the flash rewriting was not able to be executed normally E1811319 Message Data for MDE register is different from the endian which was specified on starting up E1811320 Message Data for UB code is different from the operating mode which was specified on starting up E1811324 Message When debugging the cpu re write mode the internal ROM areas can not be accessed E1811327 Message Writing process was terminated because a voltage monitoring
184. module clock PCLK is outside the range Please check the setting of the input clock EXTAL and the system clock control register SCKCR E1810316 Message As Allow to change the clock source on writing internal flash memory is not checked Internal flash memory can not be rewritten E1810317 Message Internal flash memory can not be rewritten The EXTAL value is less than the low est frequency E1810900 Message The character count of the emulator serial number is out of range E1811000 Message The firmware stored in the emulator does not correspond to the MCU to be debugged Action by User Download the correct firmware E1811001 Message The firmware stored in the emulator is a not corresponding version Action by User Check that the latest firmware is in use E1811002 Message Internal error FFWERR_TMRCTRL_OVER E1811104 Message ID code does not match E1811105 Message A JTAG communication error Please retry with reducing the JTAG clock E1811106 Message The device ID code does not match the one for the selected device Please check the device name E1811109 Message The emulator failed to connect with the MCU There is a possibility that pin states or operating mode of the MCU is not correct E1811113 Message ID code authentification failed Please turn the mcu off and try to re connect with the debugger E1811114 Message Failed to start up with user boot
185. n E1201025 Message Result of timer measurement overflowed E1201026 Message Too many event conditions with path count E1201027 Message Too many address range conditions E1201028 Message Too many simultaneously usable event conditions E1201029 Message Too many snap events E1201030 Message Too many stub events E1201031 Message Too many initialization data E1201032 Message Too large search data gt 16 byte E1201033 Message Too large search data gt search range E1201034 Message Too many event link conditions E1201184 Message Software break conditions number overflow E1201185 Message Not enough memory for emulation E1201186 Message Too many partition of bus size E1201187 Message Too many execution event conditions E1201188 Message Too many bus event conditions E1201232 Message Specified event has been already use E1201382 Message The number of specified events is greater than the settable number of events E1201424 Message The trace recording start processing did not end normally E1201425 Message The trace recording stop processing did not end normally E1201426 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Acquisition of data stored in the trace buffer in the TRC did no
186. n cate gory in Link Options tab Action by User Enter a string in accordance with the specified format W0291002 Message Section Setting dialog does not support parentheses in option start Explanation This message appears when parentheses are entered in Specify a section start address property in Section category in Link Options tab and the button is clicked instead of opening the Section Settings dialog box W0291003 Message Specify valid rule number Explanation This message appears when invalid characters have been detected in the field where MISRA C rule numbers are specified Action by User Enter valid rule numbers W0291004 Message Specify valid predefined macro Explanation This message appears when a predefined macro that is not specifiable was selected in Invalidates the predefind macro in Section category in Compile Options tab Action by User Enter a valid predefined macro W0293001 Message Watch your adding object library files In some build mode Xwhole_program is set There is a possibility that an invalid code is made for adding the obj lib file Refer to the manual for details Explanation This message appears when the Xwhole_program option is set in build properties and an obj or lib file is registered Action by User Before using the Xwhole_program option in build
187. n an external address space of the MCU Please confirm the contents of the USD file E1891802 Message The range of allocated addresses overlaps Please confirm the contents of the USD file E1891803 Message USD file is not found E1891804 Message Address is incorrect E1891805 Message Address range error E1891806 Message Work ram exceeds the RAM range E1891807 Message Custom program size exceeds its limit E1891808 Message It is not possible to allocate it beyond the boundary of the CS area Please confirm the contents of the USD file E1891809 Message Sector information in xxx is different from the previous one Continue to load it E1891810 Message USD file can not be registered when the operating mode is Single processor mode Remove the USD file information E1891900 Message Please re set start stop function E1896000 Message The specified address is over the maximum address of the target MCU E1896100 Message Stream I O error occurred E1896101 Message An undefined instruction exception has occurred E1896102 Message A privileged instruction exception has occurred E1896103 Message An access exception has occurred E1896104 Message A floating point exception has occurred E1896105 Message An error has occurred during a memory acces
188. n detected You must change the setting in that module before you can use it for other purpose W0403002 Message Frequency of clock xxx is lower than clock yyy you should change the setting in System RL78 No suitable value could be selected in valid range please reset the periphe rial clock in System module W0403003 Message Please select the trigger W0403004 Message Information of valid input value range 0x00000000000000000000 0xfffffffffffffffffffX Input 10 byte Hex value W0403005 Message Information of valid input value range 16 238 The input value must be even W0403006 Message Can not use uart for it needs two channels W0403007 Message Xxx is not selected now and you should select the clock in System module before you want to use it W0403008 Message Information of valid input value range xxx yyy W0403009 Message Source address range xxx W0403010 Message Destination address range xxx W0403011 Message The start up file for the build object was changed to xxx W0403012 Message The link directive file for the build object was changed to xxx W0403013 Message The address will overflow as a result of counting direction and byte W0403014 Message The combination operation can t be selected because its slave channel has been used for other purposes W0403015 Message P52 SLTI SLTO has been used by channel n
189. n the debug tool properties M0824002 Message Because the trace function is not effective a part of the result of Analysis Chart panel cannot be displayed Please set to use the trace function in the property of Trace category of Debug Tool Settings tab of debug tool Explanation This appears when the trace function is not enabled in the debug tool settings and the method for acquiring variables is set to trace data analysis in the Analysis Chart panel Action by User Enable the trace function in the debug tool properties M0824003 Message The specified value does not exist from the present location to the xxx of a chart Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when moving in analysis graph value trends and the specified value is not found in the direction of movement start or end is displayed in xxx ztENESAS Page 109 of 152 CS V3 00 00 M0824005 Message 5 MESSAGES There is no execution time information Explanation This appears when the trace function is not enabled in the properties of the debug ging tool or there is no trace data Action by User Enable the trace function in the properties of the debugging tool M0824006 Message The chart of the channel number xxx is never displayed Review the setting value of the properties Explanation This appears when none of the data fit with
190. nd Phase2 of event link con ditions E1216423 Message Software break conditions number which can be set as internal ROM was overflow E1216424 Message Software break can not be set because internal instruction RAM area is invalid E1217176 Message Illegal memory bank setting E1220480 Message Illegal device file type E1220481 Message Not enough memory E1220482 Message Can not open device file E1220483 Message Reading of device file went wrong E1220484 Message Can not close device file E1220485 Message Illegal device file format E1220486 Message Failed in initializing Emulator E1220487 Message Device file has broken or error is in a file E1220488 Message Can not open device file E1220489 Message Can not open ie703000 ie E1220490 Message Specified device file is illegal version E1220492 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Failed in reading expc ini ztENESAS Page 62 of 152 CS V3 00 00 E1220493 Message Not enough memory 5 MESSAGES E1221248 Message Illegal device file type E1221249 Message Not enough memory E1221250 Message Can not open database file E1221251 Message Reading of database file went wrong E1221252 Message Can not close databas
191. ng a symbol name Action by User Enter a valid symbol name W0290004 Message The Address which is already specified cannot be specified again Explanation This message appears when an address that has already been specified is speci fied again Action by User Enter a unique address W0290005 Message The Address field is empty Input an Address in the field Explanation This message appears when the address is empty Action by User Enter a valid address W0290006 Message Please enter an integer Explanation This message appears when a string that is invalid as an integer is entered in an area for specifying an integer value Action by User Enter a string that represents a valid integer W0290007 Message Please enter an integer between 0 and Oxffffff Explanation This message appears when an out of bounds value is entered into an area for specifying an address W0290008 Message The Optimizes accesses to external variables has been specified Check Outputs the external symbol allocation information file in the Output category on the Link option tab Explanation This appears when choosing the option which linked W0290009 Message The specification of Optimizes accesses to external variables has been canceled in all files in the project Uncheck Outputs the external symbol allocat
192. nnected or the MINICUBE or MINICUBE2 may be malfunctioning MINI CUBE MINICUBE2 Select Debug gt Disconnect from Debug Tool After checking the connection turn the power back on then select Debug gt Connect to Debug Tool to recon nect E1200434 Message The firmware of the emulator is old version Please update it with utility to the latest firmware E1200435 Message A setup of the wireless is not being done Please set up by the wireless utilities E1200464 Message Failed in starting simulator E1200465 Message Not enough memory in starting simulator E1200512 Message Verification error occurred Failed in writing memory E1200672 Message Bus hold error E1200674 Message Can not compulsory break E1200675 Message Reset under continuation E1200722 Message Not enough memory for trace buffer E1200768 Message User program is running E1200769 Message User program is being breaked E1200770 Message User program is being traced E1200771 Message Not traced E1200772 Message Trace memory is not set E1200774 Message No trace block exists E1200775 Message No event condition exists E1200776 Message No timer measurement is done E1200777 Message No trigger frame exists E1200778 Message Tracer is being stopped E1200779 Message Specified snap event has not been registered E1200780 Message Sp
193. not be performed ztENESAS Page 57 of 152 CS V3 00 00 E1203188 Message 5 MESSAGES CPU register cannot be accessed E1203189 Message Monitor has failed in shift in the debugging mode Please reset the CPU E1203190 Message Initial state at the time of DCU access start is unusual E1203191 Message DCU access is unusuall E1203192 Message Failed in reading of trace data E1203193 Message The on chip debug function had been disabled in the device E1203194 Message Can not write the flash memory because the clock frequency is beyond the limits of regulations E1203232 Message Can not communicate with Emulator Please confirm the power of Emulator con nection of the interface cable or I O address of the PC interface board E1203233 Message Monitor file not found E1203234 Message This device file does not include the on chip debug information E1203235 Message Unsupported information is included in the on chip debug information in the device file E1203236 Message This device file does not include the IECUBE information E1203241 Message The type of the firmware CTFW in the main emulator unit is incorrect Update it with the programming tool E1203242 Message The version of the firmware CTFW in the main emulator unit did not match Update it with the programming tool
194. nready status E1203107 R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Message Bus hold under continuation ztENESAS Page 55 of 152 CS V3 00 00 E1203108 Message 5 MESSAGES It cannot shift to debug mode Explanation There may be a problem with the connection to the target system 1 The clock may be stopped or slow 2 This occurs when there is no response from the monitor program after a reset cancellation MINICUBE2 Action by User Check the clock signal E1203109 Message Flash macro service ROM was accessed or stepped in E1203110 Message FLMD terminal is in a write protected state E1203111 Message Security flag is in a write protected state E1203112 Message Writing of flash memory is not made Internal RAM is not enough or may have dete riorated internal flash memory Action by User Replace the POD IE850 Replace the chip MINICUBE MINICUBE2 E1 E1203113 Message Failed in blank check flash memory May have deteriorated internal flash memory Action by User Replace the POD IE850 Replace the chip MINICUBE MINICUBE2 E1 E1203114 Message Failed in erasing flash memory May have deteriorated internal flash memory Action by User Replace the POD IE850 Replace the chip MINICUBE MINICUBE2 E1 E1203115 Message Failed in writing flash memory May have deterio
195. ns in the message to remedy the problem E0203014 Message No builder has been set to the project Action by User Make sure that the build tool is correctly installed E0203015 Message Adding build mode failed Explanation This message appears when an add operation fails in the Build Mode Settings dia log box Action by User Make sure the input value is correct E0203016 Message Changing build mode name failed Explanation This message appears when an invalid build mode name is entered Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Make sure the input value is correct ztENESAS Page 33 of 152 CS V3 00 00 E0203017 Message 5 MESSAGES Changing current build mode failed Explanation The specified build mode does not exist Action by User Make sure the input value is correct E0203018 Message Duplicating build mode failed Explanation The specified build mode does not exist Action by User Make sure the input value is correct E0203019 Message Removing build mode failed Explanation The specified build mode does not exist Action by User Make sure the input value is correct E0203021 Message A build mode with the same name already exists Explanation This message appears when a build mode with the same name already exi
196. nse to direct cause E1710197 Message The specified category is not found Explanation This appears when the specified category is illegal Action by User Specify the category that does exist E1710198 Message Access by stopping execution function cannot be used Explanation This message appears when the debugger does not have the function of access by stopping execution E1710199 Message Operation after trace memory is full function cannot be used Explanation This message appears when the debugger does not have the function of operation after trace memory is full E1710200 Message The specified output string is not found Action by User Specify the output string that does exist E1710201 Message Output string and variable expression conditions are not set Explanation This appears when both the output string and the variable expression condition are not set Action by User Specify the output string or the variable expression condition or both E1720000 Message Exception was generated by Python function for CS direct cause Explanation This appears when an unexpected exception occurs in the called function E1720010 Message Specified file was not found in an active project Explanation This appears when the specified file is not in the active project E1720011 Me
197. o Cancel action Q0201008 Message The file xxx already exists Overwrite Explanation This message appears in order to confirm with the user whether to overwrite a file that has already been saved Action by User Yes Overwrite the file No Return the focus to the original dialog box without overwriting the file Q0201009 Message The folder xxx already exists Overwrite Explanation This message appears in order to confirm with the user whether to overwrite a folder that has already been saved Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Yes Overwrite the folder No Return the focus to the original dialog box without overwriting the folder ztENESAS Page 114 of 152 CS V3 00 00 Q0201010 Message 5 MESSAGES Are you sure you want to change the file extension If the file extension is changed any settings of the file will be deleted Explanation This message appears to confirm that you wish to change the file extension in the project tree Action by User Yes Change the file extension No Cancel action Q0202001 Message Saving the project components may take a few minutes to a few dozen minutes Start processing Explanation This appears when the Save Project and product name as Package menu item is selected Action by User Yes Execute processing
198. o in the debugging tool Action by User OK Change the endianness of the debug tool Cancel Cancel action Q0210007 Message Also enable the trace function of a debugging tool Explanation This appears when the trace RAM warning property setting is changed in the build tool and the application confirms whether you want to change the enable trace property setting in the debugging tool as well Action by User OK Enable the trace function of a debugging tool Cancel Cancel action Q0210008 Message Also disable the trace function of a debugging tool Explanation This appears when the trace RAM warning property setting is changed in the build tool and the application confirms whether you want to change the enable trace property setting in the debugging tool as well Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 OK Disable the trace function of a debugging tool Cancel Cancel action ztENESAS Page 118 of 152 CS V3 00 00 Q0212001 Message 5 MESSAGES The I O protection area has been set in the specified target memory area Also delete the I O protection area Explanation This message appears when removing a target memory area and an I O protected area has been set on this area Action by User OK Delete the I O protection area Cancel Cancel action Q0225001 Message Al
199. o save the file as a different name or overwrite it Explanation This message dialog box appears when attempting to save an editor source file that is read only on disk Action by User Save As This will open a Save As dialog box to allow saving the file as a different file name Overwrite This will overwrite the existing read only file The read only attribute will be changed to readable writable Cancel This will cancel the operation that resulted in the prompt to save the file Q2000005 Message xxxyyyzzzThis file may have been changed by another program Would you like to reload it Explanation This message dialog box appears when a source file that is open in the editor has been modified externally in another application Action by User Yes This will reload the editor source file losing any unsaved modifications since the last save time of the file No This will ignore the external changes to the file and will leave the Editor panel exactly as it is Any unsaved changes will remain Cancel This will perform the same as the No button ignoring any external changes to the file and leaving the Editor panel as it is Q2000006 Message Generating a print image for large files may take a long time Do you wish to con tinue Explanation This message appears when the Print or Print Preview menu was selected for a file with 1000 or more lin
200. ode and termina tion code is incorrect Please restart the emulator and the debugger E1817004 Message A communication error Incorrect data excluding the start command error and termination codes have been received from emulator firmware Please restart the emulator and the debugger E1817005 Message A communication error Failed to send a command to emulator firmware since some data remains in the buffer This is because larger data has been received in processing of the previous command Please restart the emulator and the debug ger E1817006 Message A communication error At the first command sending and receiving with emulator firmware Please restart the emulator and the debugger E1817007 Message A communication error The error occurred after having changed the USB forward ing size Please restart the emulator and the debugger E1818000 Message Could not find the firmware rewrite program Please re install the debugger E1818001 Message Internal error FFWERR_WTR_NOTLOAD Writing control program is not loaded E1818002 Message Unsupported operation was invoked Explanation This operation is not supported by the emulator E1818003 Message Memory allocation failed Action by User Close unused panels so that the required amount of memory becomes available E1830000 Message The specified parameter is incorrect
201. ode of the file The encode of xxx must be specified for the encode of the file Explanation This appears when the encoding of a file being loaded or imported is not sup ported Action by User Specify a correct file encoding W0202001 Message Diverting the project failed The file composition and the properties of the tool is not applied Explanation This appears in cases such as when creating a new project using the copy project feature and the project to copy could not be parsed The properties of the file hier archy or tools could not be applied Action by User Copy a file that can be parsed successfully W0202002 Message Applying the properties of the tool failed Target tools xxx Explanation This appears in cases such as when creating a new project using the copy project feature and a failure occurs while applying the tool properties The file hierarchy of the copied project file has been applied Action by User Copy a file that can be parsed successfully W0202003 Message The project file can be restored But if you save the project some information may be lost Explanation Tried to read the project file by which the compatibility isn t perfection Can return but when saved overwrite a part of information is lost Action by User Confirm whether it s identical with tool version made created project file When it s necessary
202. of an existing address range Action by User Change the address or size of the memory area W0261013 Message The start address of segment is invalid Specify the address of the memory area to be placed Explanation This message appears when the address of a segment specified in the Link Direc tive File Generation dialog box is outside the memory area to which the segment is to be allocated Action by User Specify an address within the memory area to which the segment is to be allo cated W0290001 Message The Section field is empty Input a correct section name Explanation This message appears when the section is empty Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Enter a valid section ztENESAS Page 137 of 152 CS V3 00 00 wo0290002 Message 5 MESSAGES Use only the following characters in the field except that 0 9 cannot be the first let ter of a section name A Z a z 0 9_ Explanation This message appears when a string that is invalid as a section name is entered in an area for specifying a section name Action by User Enter a valid section W0290003 Message Use only the following characters in the field except that 0 9 cannot be the first let ter of a symbol A Z a z 0 9_ Explanation This message appears when a string that is invalid as a symbol name is entered in an area for specifyi
203. on This error occurs when the program fails to remote a prohibition on project actions Action by User Wait until the current process completes E0202041 Message Projects and windows cannot be closed during build Explanation This error occurs when failing to close a project Action by User Projects cannot be closed during a build E0202042 Message Projects and windows cannot be closed during search Explanation This error occurs when failing to close a project Action by User Projects cannot be closed during a search E0202044 Message Restoring object options failed Explanation Failed to restore object options from the project file Action by User Check the version of the project file E0202045 Message Saving ROMize options failed Explanation Failed to save ROM creation process options to the project file Action by User Check the version of the project file E0202046 Message Restoring ROMize options failed Explanation Failed to restore ROM creation process options from the project file Action by User Check the version of the project file E0202047 Message Saving archive options failed Explanation Failed to save archive options to the project file Action by User Check the version of the project file E0202048 Message Restoring a
204. ontinue Action by User Yes Delete the column No Close the dialog box without deleting the column Q0300004 Message Do you want to delete the external peripheral lt external peripheral name gt If you delete the external peripheral the pins connected to the external peripheral is dis connected Action by User Yes Delete the external peripheral Disconnect the pin No Return to the original status without changing the settings Q0300005_ Message All the settings you have done in the pin configurator will be lost Do you want to change the package type Action by User Yes This will modify the package Pin settings and external peripherals will be returned to their default values No Return to the original status without changing the settings Q0300006_ Message Disconnecting the pin No lt selected pin numbers from the external peripheral lt external peripheral name gt Continue Action by User Yes This disconnects the pin from the external periphery No Return to the original status without changing the settings Q0300007 Message lt File name gt already exists Do you want to replace it Action by User Yes Overwrite save the file No Return to the original status without changing the settings Q0300008 Message One or more pins are connected to the external peripheral s If you change the settings the pins are disconnected Do you want to change all settings
205. or occurs when the Editor panel fails to detect the file s character encoding Action by User The maximum text length has been exceeded E0223006 Message Upper bounds of the number of nests of categories xxx that were able to be regis tered in the project tree were exceeded Explanation The maximum allowable level of category nesting was exceeded while adding a category to the project tree Action by User Add the category to the project so that the maximum nesting level is not exceeded R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 42 of 152 CS V3 00 00 E0223007 Message 5 MESSAGES Failed to open the Windows Explorer menu for the specified file or folder Explanation This message appears when the Windows Explorer menu was not displayed in the Project Tree panel Action by User When multiple nodes have been selected check that all of them are files or fold ers in the same folder Check that you have access rights for the files and folders Check that the files and folders exist E0223008 Message Failed to get information for specified files or folders or not contains in a same par ent folder Explanation This message appears when the Windows Explorer menu was not displayed in the Project Tree panel Action by User When multiple nodes have been selected check that all of them are files or fold ers in the same folder
206. our Renesas Electronics over seas representative E0113003 Message An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0113004 Message An internal error occurred in Update Manager Failed to download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0113005 Message An internal error occurred in Update Manager Failed to download Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Please contact your vendor or your Renesas Electronics overseas representative ztENESAS Page 17 of 152 CS V3 00 00 E0113006 Message 5 MESSAGES A connection with the server is untrusted A server certificate for secure connection could not be validated Please retry the operation after a while Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0113007 Message A secure connection with the server could not be established Please retry the operation after a while Action by User Make sure that you can display secure Internet sites starting with https in Internet Explorer Contact your network administrator if you cannot If you can display Internet sites there is probably a temporary issue with the serv
207. pears when an undefined combination of options is specified Action by User Specify the options correctly E0219001 Message Executing external tool failed Explanation This message appears when an external tool could not be executed e g the file was not found from the Tool or Tool name menu Action by User Make sure that the path of the specified command is correct E0220001 Message Jump to source failed Explanation This message appears when an exception is thrown when executing the Jump to Source menu command Action by User There may be no source information at the specified location In this case it is not possible to jump from here Check whether the target source file exists Make sure that the debugging tool is connected E0220002 Message Jump to disassemble failed Explanation This message appears when an exception is thrown when executing the Jump to Disassembly menu command Action by User The program may have failed to obtain the jump destination address from the specified location In this case it is not possible to jump from here Make sure that the debugging tool is connected E0220003 Message Jump to memory failed Explanation This message appears when an exception is thrown when executing the Jump to Memory menu command Action by User The program may have failed to obtain the jump
208. pears when the specified file does not exist E1720111 Message Debug tool is connected if you want to change the project please disconnect from the debugging tools Explanation This appears when attempting to change the active project while connected to a debugging tool E1720112 Message Project is not loaded Explanation This appears when an action is performed on a project that is not loaded E1720113 Message Failed to save the project direct cause Explanation This appears when saving the project fails E1720114 Message Please enter the category specified in the string Explanation This appears when the specified category is not a string E1720115 Message Failed to get the state of the project direct cause Explanation This appears on failure to obtain the current project in CS E1720116 Message Failed to check the file direct cause Explanation This appears on failure to check a project file E1720117 Message Xxx has already been set Explanation This appears when attempting to add a file that is already set in the project E1720118 Message The specified project was not found Explanation This appears when the specified project path is not found E1720119 Message Failed to close the project Explanation This message appears in case of fa
209. pecification of the main clock source is mistake E0602205 Message The specification of the sub clock source is mistake E0602206 Message Illegal the flash self emulation settings E0602207 Message Illegal the DataFlash emulation settings E0602208 Message Illegal the memory mapping settings E0602209 Message The coverage board is not equipped with E0602210 Message Could not create the simulator project file xxx E0602211 Message SymbolLoad cannot be nested E0602212 Message Please install runtime components of Visual C 2010 SP1 Libraries xxx E0602213 Message Debugger I F used from a thread other than the thread the debugger was created on E0602214 Message Specified feature is not supported xxx E0604000 Message Failed to assemble xxx E0608000 Message It failed in the preservation of the xxx because the right of access of the coverage file had not been permitted or the capacity of the disk was insufficient R20UT3099EJ0100 Rev 1 00 ztENESAS Page 48 of 152 Aug 01 2014 CS V3 00 00 5 MESSAGES E0608001 Message It failed in reading the xxx because the coverage file did not exist or the right of access had not been permitted E0608002 Message The verify error occurred while reading the xxx because abnormality had been found in the coverage file E0608003 Message The code flash area doesn t exist E0608004 Message The data flash area doesn t exist E06080
210. pecified name is illegal Explanation This appears when access to a Pip execution instance fails C1813701 Message Internal error FFWERR_BEXE_LEVELO C1813702 Message Internal error FFWERR_EML_ENDCODE C1813703 Message Internal error FFWERR_FDT_ENDCODE C1813704 Message Internal error FFWERR_EML_TO_FDT C1813705 Message Internal error FFWERR_FDT_TO_EML C1813706 Message Internal error FFWERR_MONP_ILLEGALEML R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 11 of 152 CS V3 00 00 5 MESSAGES 5 2 Fatal Errors Table 5 2 Fatal Errors E0020001 Message Cannot find product list file xxxx E0020002 Message Not Support this device xxxx E0020003 Message Cannot read file E0021001 Message Cannot find product file xxxx E0021002 Message Not Support this device xxxx E0021003 Message Cannot read file E0021004 Message Failed update of Device dependent information E0022001 Message Not Support this device xxxx E0022002 Message Cannot find terminal information file xxxx E0022003 Message Cannot read file E0023001 Message Not Support this device xxxx E0023002 Message Cannot find device file xxxx E0023003 Message Cannot find device extended information file xxxx E0023004 Message Cannot read file E0023005
211. pecified terminal name in the Signal Data editor is incorrect target device does not exist Action by User Specify the terminal name for an existing target device E1310503 Message Illegal loop count Explanation The loop count in the Loop Setup dialog box is invalid or outside the valid range 0 to 99 Action by User Specify a correct value E1310700 Message The pin name is invalid Explanation The specified terminal name in the I O panel is incorrect target device does not exist Action by User Specify the terminal name for an existing target device E1310702 Message Illegal thickness of line Explanation The line weight specified in the I O panel Style Settings is invalid or outside the valid range 1 to 100 Action by User Specify a correct value E1310703 Message Illegal hold time Explanation The hold time specified in the I O panel Input Component Settings is invalid or out side the valid range 0 001 to 999 Action by User Specify a correct value E1310704 Message Illegalmuximuminput Explanation The maximum input value specified in the I O panel Level Gauge Settings is invalid or outside the valid range 1 to 65 535 Action by User Specify a correct value E1310710 Message Abitmap path is not specified Explanation In the I O panel under A
212. pment environment for developing applications and sys tems for RH850 family RX family RL78 family and provides an outline of its features CS is an integrated development environment IDE for RH850 family RX family RL78 family integrating the neces sary tools for the development phase of software e g design implementation and debugging into a single platform By providing an integrated environment it is possible to perform all development using just this product without the need to use many different tools separately Readers Purpose Organization How to Read This Manual Conventions This manual is intended for users who wish to understand the functions of the CS and design software and hardware application systems This manual is intended to give users an understanding of the functions of the CS to use for reference in developing the hardware or software of systems using these devices This manual can be broadly divided into the following units 1 GENERAL 2 MESSAGE FORMATS 3 MESSAGE TYPES 4 COMPONENT NUMBERS 5 MESSAGES It is assumed that the readers of this manual have general knowledge of electricity logic circuits and microcontrollers Data significance Higher digits on the left and lower digits on the right Active low representation XXX overscore over pin or signal name Note Footnote for item marked with Note in the text Caution Information requiring particular attention Remark Supplementary
213. ppears to confirm whether to proceed with a given action Action by User Ok Continue action Cancel Cancel action Q0200002 Message You need to restart this product to take effect Do you want to restart now Explanation This appears when confirming a reboot Action by User Yes Continue action No Cancel action Q0201001 Message xxx has been changed Save Explanation This Message dialog box appears to confirm whether you want to save a changed file when closing a window or the like xxx is replaced by the display name of the open window file name or panel name When closing a project xxx is replaced by Project If there are two or more items this string is changed to Items Action by User Yes Save the content before closing the window or panel No Discard any changes and close the window or panel Cancel Stay in current state without closing the window Q0201002 Message xxx may have been changed by another program Overwrite save Explanation This message appears when saving a file and for some reason the last modified date is more recent than the time the file was opened or the time of the last save Action by User Yes Overwrite and save No Cancel action Q0201003 Message Folder does not exist Create folder Explanation This appears to ask the user whether to
214. properties make sure that none of the variables or functions to be compiled are referenced by external modules W0293002 Message The Optimizes accesses to external variables has been specified Check Outputs the external symbol allocation information file in the Output category on the Link option tab Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when the compiler option Omap is set in the CC RH build properties but the linker MAp option is not set to ON After displaying this warning the build plug in automatically enables the linker s MAp option ztENESAS Page 139 of 152 CS V3 00 00 W0293003 Message 5 MESSAGES The specification of Optimizes accesses to external variables has been canceled in all files in the project Uncheck Output external symbol allocation information file in the Optimization Details category on the Link option tab Explanation This message appears when the selected option is used in conjunction with another option W0293004 Message The file name is invalid The characters lt gt cannot be used Explanation This message appears when the filename includes invalid characters Action by User Specify a valid filename W0294001 Message Watch your adding object library file s In some build mode Owhole_program is set There is a possibility that an invalid code is
215. ptions failed Explanation Failed to save compile options to the project file Action by User Check the version of the project file E0202022 Message Restoring compile options failed Explanation Failed to restore compile options from the project file Action by User Check the version of the project file E0202023 Message Saving assemble options failed Explanation Failed to save assembly options to the project file Action by User Check the version of the project file E0202024 Message Restoring assemble options failed Explanation Failed to restore assembly options from the project file Action by User Check the version of the project file E0202025 Message Saving link options failed Explanation Failed to save link options to the project file Action by User Check the version of the project file E0202026 Message Restoring link options failed Explanation Failed to restore link options from the project file Action by User Check the version of the project file E0202027 Message Saving library options failed Explanation Failed to save library options to the project file Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Check the version of the project file ztENESAS Page 27 of 152 CS V3 00 00 E0202028 Messa
216. py the current compiler options to the assembler options for the current build mode only Cancel Cancel the command Q0294006_ Message Are you sure you want to set the current compile options to the individual assemble options for all build modes If No is selected copy the current build mode options only Explanation This is to confirm the scope of individual assembler options when they are set with simultaneous build enabled in CC RL Action by User Yes Execute the command No Copy the current compiler options to the individual assembler options for the cur rent build mode only Cancel Cancel the command R20UT3099EJ0100 Rev 1 00 ztENESAS Page 123 of 152 Aug 01 2014 CS V3 00 00 5 MESSAGES Q0300001 Message The pin is connected to the external peripheral lt external peripheral name gt If you change the setting the pin is disconnected Do you want to change the setting Action by User Yes Disconnect from the external peripheral and change the settings No Close the dialog box without changing the settings Q0300002 Message The selected pin No lt selected pin No gt is used in lt macro function gt Do you want to change the setting Action by User Yes Change the settings No Close the dialog box without changing the settings Q0300003 Message Deleting the column lt column name gt C
217. quisition of the processor element went wrong direct cause Explanation This appears on failure to obtain the processor number from the IDE E1710144 Message A setup of the processor element went wrong direct cause Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears on failure to set the processor number from the IDE 2tENESAS Page 78 of 152 CS V3 00 00 E1710145 Message 5 MESSAGES Function is not supported Explanation This appears when specific user added information is not found when CS starts Action by User Add the user added information and restart E1710146 Message Failed to set ADConvertInExcution direct cause Explanation This appears on failure to access the data collection feature E1710147 Message Failed to get ADConvertlnExcution direct cause Explanation This appears on failure to set the data collection feature E1710148 Message ADConvertInExcution function is not supported Explanation This appears when the data collection feature is not supported E1710149 Message Failed to start the trace direct cause Explanation This appears on failure to start tracing during execution E1710150 Message Cannot start the trace Explanation This appears on failure to start tracing during execution E1710151 Message Fa
218. r Action by User Specify a valid path W0603013 Message The file name or path name is invalid The characters lt gt cannot be used Explanation The string includes illegal characters Action by User Specify a valid filename or path W0603014 Message The format is invalid Explanation This message appears when a string with invalid format is entered into the proper ties or the like having a specific string format Action by User Enter a string in accordance with the specified format W0603015 Message Specify in hexadecimal Explanation This message appears when a string containing characters that are invalid as a hexadecimal number was entered in a hexadecimal base 16 numeric field Action by User Specify a string that represents a valid number in hexadecimal notation W0603016 Message Specify in decimal or hexadecimal Explanation This message appears when a string containing characters that are invalid as a decimal hexadecimal number was entered in a decimal base 10 hexadecimal base 16 numeric field Action by User Specify a string that represents a valid number in decimal hexadecimal notation W0603017 Message Enter a value smaller than the end address for the start address Explanation This message appears when an area in which an address or symbol range is spec i
219. r Solve the problem indicated as direct cause E1710176 Message Failed to enable the trace event direct cause Explanation This message appears when the debugger has failed to enable a trace event Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Solve the problem indicated as direct cause ztENESAS Page 81 of 152 CS V3 00 00 E1710177 Message 5 MESSAGES Failed to disable the trace event direct cause Explanation This message appears when the debugger has failed to disable a trace event Action by User Solve the problem indicated as direct cause E1710178 Message Failed to set the start trace event item direct cause Explanation This message appears when the debugger was unable to set the condition for starting a trace event Action by User Solve the problem indicated as direct cause E1710179 Message Failed to set the end trace event item direct cause Explanation This message appears when the debugger was unable to set the condition for end ing a trace event Action by User Solve the problem indicated as direct cause E1710180 Message The section timer is not supported in this debugger Explanation This appears when a debugger doesn t support the section timer E1710181 Message The access event of section timer is not supported in this debu
220. r Specify a string that represents a valid number W0603007 Message Specify in decimal Explanation This message appears when a string containing characters that are invalid as a decimal number was entered in a decimal base 10 numeric field Action by User Specify a string that represents a valid number in decimal notation W0603008 Message Fewer than xxx or more than yyy values cannot be specified Explanation This message appears when an out of bounds value is entered into a numeric input area in the properties or the like Action by User Specify a value between xxx and yyy W0603009 Message Only ASCII character sets can be entered Explanation This message appears when a string containing other than ASCII or numeric char acters was entered in a field where only numbers or ASCII strings can be specified Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a string that is a valid number or a valid ASCII string ztENESAS Page 143 of 152 CS V3 00 00 W0603010 Message 5 MESSAGES Specify a character string Explanation The field is empty Action by User Specify a valid string W0603011 Message Specify a path Explanation The field is empty Action by User Specify a valid path W0603012 Message The specified path contains a non existent folde
221. r Specify a value between xxx and yyy W0205009 Message Only ASCII character sets can be entered Explanation Numeric or ASCII characters specifying an area include characters that are not numeric or ASCII Action by User Specify a string that is a valid number or a valid ASCII string W0205010 Message Specify a character string Explanation The field is empty Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a valid string ztENESAS Page 130 of 152 CS V3 00 00 W0205011 Message 5 MESSAGES Specify a path Explanation The field is empty Action by User Specify a valid path W0205012 Message The specified path contains a non existent folder Explanation The specified path includes a non existent folder Action by User Specify a valid path W0205013 Message The file name or path name is invalid The characters lt gt cannot be used Explanation The string includes illegal characters Action by User Specify a valid path W0205014 Message The format is invalid Explanation This message appears when a string with invalid format is entered into the proper ties or the like having a specific format Action by User Enter a string in accordance with the specified format W0205015 Message Specify in hexadeci
222. r displayed by CS The component number 2 digits categories when CS is operated are as follows Table 4 1 Component Number Component Number Description Common processing Update Manager Installer License Manager Integrated Development Environment Framework Design Tool Pin Configurator Design Tool Code Generator Debug Tool Emulator Simulator Analyze Tool Debug Tool Emulator Simulator Debug Tool Simulator Console Debug Tool Editor I O header file Generation Tool R20UT3099EJ0100 Rev 1 00 Aug 01 2014 ztENESAS Page 8 of 152 CS V3 00 00 5 MESSAGES 5 MESSAGES This chapter describes the messages displayed by CS R20UT3099EJ0100 Rev 1 00 ztENESAS Page 9 of 152 Aug 01 2014 CS V3 00 00 5 MESSAGES 5 1 Internal Errors Table 5 1 Internal Errors C0100001 Message Xxx is empty C0100002 Message Xxx is too large C0100003 Message Unexpected xxx is specified C0149999 Message Internal Error Exceeds check_folder limit 1024 Explanation This appears when the limit value 1024 of target on a start process check was exceeded Message Internal Error VIA_LENV_SETUP is not correct Explanation This appears when the installer for installing a required environment calls the inte grated installer and an integration insta
223. r package ztENESAS Page 115 of 152 CS V3 00 00 5 MESSAGES Q0202006 Message Xxx is not a subproject for the yyy Are you sure you want to just open the subproject If you just open the subproject only file structure will be restored and you will not be able to build and debug the project If you would like to build and debug open the subproject by the proper CS Explanation This appears when attempting to add a sub project from another package Q0203001 Message Are you sure you want to set the current compile options to the individual compile options for all build modes If No is selected copy the current build mode options only Explanation This appears when specifying the individual compile options Action by User Yes The individual compiler options are set for all build mode No The individual compiler options are only set for the current build mode Cancel Cancel action Q0203002 Message Are you sure you want to set the current assemble options to the individual assem ble options for all build modes Explanation This appears when specifying the individual assemble options Action by User Yes The individual compiler options are set for all build mode No The individual compiler options are only set for the current build mode Cancel Cancel action Q0203003 Message Are you sure you want to copy the current compile options to the assemble opt
224. rated internal flash memory Action by User Replace the POD IE850 Replace the chip MINICUBE MINICUBE2 E1 E1203116 Message Failed in internal verification flash memory May have deteriorated internal flash memory Action by User Replace the POD IE850 Replace the chip MINICUBE MINICUBE2 E1 E1203117 Message Failed in writing flash memory E1203118 Message There is no response from flash macro service May have deteriorated internal flash memory Action by User Replace the POD IE850 Replace the chip MINICUBE MINICUBE2 E1 E1203119 Message Response from flash macro service is not right May have deteriorated internal flash memory Action by User Replace the POD IE850 Replace the chip MINICUBE MINICUBE2 E1 E1203120 Message Flash I O register operation prohibition setup needs to be canceled E1203121 Message STOP mode under continuation Can not compulsory break Please release STOP mode or reset the CPU E1203123 Message Disabling the on chip debug function is prohibited E1203124 Message Writing to the on chip debug reserved area is prohibited E1203125 Message The program for flash writing cannot be written in internal RAM E1203126 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Abnormal Internal ROM size The size is different from the default of th
225. rchive options failed Explanation Failed to restore archive options from the project file Action by User Check the version of the project file E0202049 Message This is not a convertible PM project file Explanation This error occurs when attempting to open a PM project prj older than version 6 00 CS can only handle PM project format version 6 00 and above Action by User Specify a project file which can be handled by this product to open E0202050 Message The location specified as save destination is invalid Specify a folder other than the project folder Explanation The path specified as the creation location is illegal Action by User Specify a different creation location E0202051 Message Saving section file generate options failed Explanation Failed to save section file generation options to the project file Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Check the version of the project file 2tENESAS Page 29 of 152 CS V3 00 00 E0202052 Message 5 MESSAGES Restoring section file generate options failed Explanation Failed to restore section file generation options form the project file Action by User Check the version of the project file E0202053 Message Saving cross reference options failed Explanation Failed to save cross referen
226. recording to timer could not be done Specify a global variable Explanation Failed to configure timer control when a global variable is read written or read written Specify a global variable in the Editor panel or Watch panel Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a global variable in the Editor panel or Watch panel ztENESAS Page 132 of 152 CS V3 00 00 Ww0209001 Message 5 MESSAGES Executing program Explanation The action cannot be performed because the program is running Action by User Perform the action again after the program execution halts W0210001 Message The connection to the debugger was completed but the following problem may exist Explanation Displays a warning to check the connection of the target card Action by User Check the connection of the conversion adapter EA We recommend attaching the conversion adapter when a target is not connected W0210002 Message Download was completed but the following problem may exist Explanation A warning appears upon download W0210003 Message Software break and hardware break are conflicted Invalid instruction may be exe cuted by restart Explanation This appears when software break and hardware break are conflicted Action by User The PC value may be invalid Reset CPU and execute it again W021200
227. relocation options failed Explanation Failed to restore memory bank allocation options from the project file Action by User Check the version of the project file E0202061 Message Saving variables functions information options failed Explanation Failed to save variable function information options to the project file Action by User Check the version of the project file E0202062 Message Restoring variables functions information options failed Explanation Failed to restore variable function information options from the project file Action by User Check the version of the project file E0202063 Message Saving link directive setting information failed Explanation Failed to save link directive configuration data to the project file Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Check the version of the project file ztENESAS Page 30 of 152 CS V3 00 00 E0202064 Message 5 MESSAGES Restoring link directive setting information failed Explanation Failed to restore link directive configuration data from the project file Action by User Check the version of the project file E0202065 Message Upper bounds of the number of files xxx that is able to be registered in the project were exceeded Explanation The maximum number of files that can be registered was exc
228. ropriate measures in response to direct cause ztENESAS Page 82 of 152 CS V3 00 00 E1710187 Message 5 MESSAGES Failed to enable the action event direct cause Explanation This message appears when the debugger has failed to enable the action event Action by User Take appropriate measures in response to direct cause E1710188 Message Failed to enable the specified action event direct cause Explanation This message appears when the debugger has failed to enable the action event Action by User Take appropriate measures in response to direct cause E1710189 Message Failed to disable the action event direct cause Explanation This message appears when the debugger has failed to disable the action event Action by User Take appropriate measures in response to direct cause E1710190 Message Failed to disable the specified action event direct cause Explanation This message appears when the debugger has failed to disable the action event Action by User Take appropriate measures in response to direct cause E1710191 Message The specified action event was not found Explanation This appears when the specified action event number is illegal Action by User Specify the number of an action event that does exist E1710192 Message Address or variable expression
229. rrect Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111005 Message Failed to write downloaded file Aborting the download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0111006 Message Failed to write downloaded file The response from the server was not correct Please check for updates after a while Explanation This appears when there is an error in the update information on the server Action by User Please check for updates after a while If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111007 Message Failed to write downloaded file xxx Aborting the download Action by User Make sure that it is possible to write files in the path specified in the message If you cannot identify the cause please contact your vendor or your Renesas Elec tronics overseas representative E0111008 Message Failed to write downloaded file xxx Aborting the download Action by User Make sure that it is possible to write files in the path specified in the message If you cannot identify the cause please contact your vendor or your Renesas Elec tronics overseas representative E0111
230. rror Please retry the operation after a while Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0112300 Message The server returned invalid response Please retry the operation after a while Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0112406 Message Failed to authenticate with proxy server at xxx Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Enter your user name and password in the Proxy Authentication dialog box If you are unclear about anything please contact your network administrator ztENESAS Page 16 of 152 CS V3 00 00 E0112503 Message 5 MESSAGES The server is temporary unavailable Please retry the operation after a while Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0112996 Message Failed to authenticate with proxy server Action by User Enter your user name and password in the Proxy Authentication dialog box If you are unclear about anything please contact your network administrator E0112997 Message Failed to authenticate with proxy server at xxx Failed to recognize authentication scheme yyy that the server requires Action by User Please contact your vendor
231. s E1896106 Message Information on interrupt is incorrect E1896107 Message An error has occurred during a memory access to the peripheral function E1899000 Message Unable to connect to the emulator xxx E1899050 Message A software break has already been set to the address E1899051 Message The software break cannot be added any further E1899100 Message The trace extract event can be Data Access events E1899101 Message Specified event type accepts execution address event only E1899900 Message Undefined error E1899901 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 I F is not supported ztENESAS Page 100 of 152 CS V3 00 00 E1899902 Message 5 MESSAGES Memory allocation failed E1899903 Message Mcu file loading failed E1899904 Message Target device driver missing connection cancelled E1899905 Message The system was reset E1899906 Message File opening failed E1899907 Message File loading failed E1899908 Message This function interrupted processing because it was not able to use it while execut ing it E2000002 Message Error opening file xxxyyyzzz Explanation This message dialog box appears when an error occurred attempting to open the specified file E2000003 Message Error saving file
232. s Electronics Europe GmbH Arcadiastrasse 10 40472 D sseldorf Germany Tel 49 211 6503 0 Fax 49 211 6503 1327 Renesas Electronics China Co Ltd Room 1709 Quantum Plaza No 27 ZhiChunLu Haidian District Beijing 100191 P R China Tel 86 10 8235 1155 Fax 86 10 8235 7679 Renesas Electronics Shanghai Co Ltd Unit 301 Tower A Central Towers 555 Langao Road Putuo District Shanghai P R China 200333 Tel 86 21 2226 0888 Fax 86 21 2226 0999 Renesas Electronics Hong Kong Limited Unit 1601 1613 16 F Tower 2 Grand Century Place 193 Prince Edward Road West Mongkok Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2886 9022 9044 Renesas Electronics Taiwan Co Ltd 13F No 363 Fu Shing North Road Taipei 10543 Taiwan Tel 886 2 8175 9600 Fax 886 2 8175 9670 Renesas Electronics Singapore Pte Ltd 80 Bendemeer Road Unit 06 02 Hyflux Innovation Centre Singapore 339949 Tel 65 6213 0200 Fax 65 6213 0300 Renesas Electronics Malaysia Sdn Bhd Unit 906 Block B Menara Amcorp Amcorp Trade Centre No 18 Jin Persiaran Barat 46050 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 60 3 7955 9390 Fax 60 3 7955 9510 Renesas Electronics Korea Co Ltd 12F 234 Teheran ro Gangnam Ku Seoul 135 920 Korea Tel 82 2 558 3737 Fax 82 2 558 5141 2014 Renesas Electronics Corporation and Renesas Solutions Corp All rights reserved Colophon 3 0 CS V3 00 00 RENESAS Rene
233. s appears when Cancel is clicked on a wizard page Q0140035 Message The following applications in the installation folder are running Close these applications and click Retry to continue The application may display the icon in the notification area system tray XXX XXX XXX Explanation This appears when a CS associated tool is running while the integrated installer uninstaller is being operated Q0140045 Message Are you sure you want to cancel the installation The following products installation has been completed XXX Please install the latest service packs and security updates for this product using Windows Update and Microsoft Upadte Explanation This message appears when all installation of required environments has com pleted successfully without a reboot request and the user then clicks Cancel in the windows of the integrated installer that is executed subsequently R20UT3099EJ0100 Rev 1 00 ztENESAS Page 112 of 152 Aug 01 2014 CS V3 00 00 Q0181000 Message 5 MESSAGES XXXXXX If you remove this license key following license key is also removed because of dependence yyyyyy Do you remove these licenses Q0181003 Message XXXXXX This license key includes registered license key yyyyyy Do you remove registered license key and add new license key Q0200001 Message Continue the processing Explanation This message a
234. sas Electronics Corporation R20UT3099EJ0100
235. se keys M0200001 Message Please enter the e mail address of your technical support contact M0200002 Message The following plug ins are not enabled XXXXXXXXXXXX You can use Plug in Manager dialog to enable these plug ins Explanation The Basic plug in and Additional plug in are disabled M0201001 Message The specified path is read only Explanation This appears when failing in writing in of a generated log file when performing con version of a project diversion of a project or pack function of the project Action by User Make the folder writeable in Explorer or the like M0201003 Message Saving the data to the file Explanation This is the string shown in the Progress Status dialog box when data is being saved to a file M0201004 Message The processing was canceled by the user Explanation The ongoing action was cancelled by the user M0201005 Message The specified file is read only Explanation This message appears when the specified file is write protected after checking file write Action by User Make the folder writeable in Explorer or the like M0201006 Message Adding folder Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when a folder is dropped from Explorer into the project tree and the contents of the folder are added ztENESAS
236. space in HEW 4 07 00 or a later version save after activating the session and repeat the conversion E0292031 Message Project project name has no relation to a toolchain Conversion of debugger only project is not supported Action by User Specify a valid Project E0293002 Message Launching program xxx failed Explanation This appears when Windows program execution was attempted from the IDE but failed Action by User Check that the program exists Check that the specified program is an executable application E0293003 Message Symbol address file xxx of the constituent application project yyy doesn t exist Explanation This appears when the fsy file that should have been output by a constituent appli cation was not found during building of the boot loader project E0294002 Message Launching program xxx failed Explanation You have attempted to run a Windows program from the IDE and this has failed Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Check that the program exists Check that the specified program is an executable application ztENESAS Page 47 of 152 CS V3 00 00 5 MESSAGES E0300001 Message Can not find file name to start pin configurator plug in Action by User Make sure that the files are included I
237. specified as ASCII Action by User Use the Memory Value Display area to paste text in other than ASCII encoding W0243004 Message Cannot paste because the area contain write protected area Explanation This message appears when a memory value or ASCII characters are pasted into the Memory panel and the area being pasted into is read only Action by User Change the length of text copied or the location copied to in order to avoid pasting into a read only area W0244001 Message Too many initialization data Only up to 16 initialization data can be specified Explanation This message appears when 17 or more initial values are entered in the Memory Initialize dialog box then the OK button is clicked Action by User Set 16 or fewer initial values W0244002 Message Each initialization data cannot exceed 4 bytes Explanation This message appears when an initial value is 5 bytes or larger in size Action by User Specify an initial value of no more than 4 bytes in size W0244003 Message Enter the initialization data Explanation This message appears when the initial data textbox in the Memory Initialize dialog box is left empty and the OK button is clicked Action by User Enter initial values in the input box W0244004 Message Enter the initialization data in hexadecimal Explanation This messag
238. ssage An error occurred during rebuild Explanation This appears when an error occurred during the rebuild Action by User Follow the instructions in the message to remedy the problem E0203003 Message An error occurred during clean Explanation This appears when an error occurred during a clean operation Action by User Follow the instructions in the message to remedy the problem E0203004 Message An error occurred while build was stopped Explanation This appears when an error occurred stopping the build Action by User Follow the instructions in the message to remedy the problem E0203005 Message Batch build failed Explanation This message appears when an exception not a build error is thrown when exe cuting a batch build from the Batch Build dialog box Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Make sure that the build tool exists ztENESAS Page 32 of 152 CS V3 00 00 E0203006 Message 5 MESSAGES Batch rebuild failed Explanation This message appears when an exception not a build error is thrown when exe cuting a batch rebuild from the Batch Build dialog box Action by User Make sure that the build tool exists E0203007 Message Batch clean failed Explanation This message appears when an exception not a build error is thrown when exe cu
239. ssage Failed in the clean project direct cause Explanation This appears when cleaning of the project fails E1720012 Message Specified build name is empty or null Explanation This appears when the null character or null is specified as the argument E1720013 Message Failed in change BuildMode direct cause Explanation This appears when the change of the build mode fails E1720014 Message building acquisition of being inside went wrong direct cause Explanation This appears on failure to obtain the building or other flag E1720015 Message Acquisition of a library file went wrong direct cause Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears on failure to obtain the library file ztENESAS Page 84 of 152 CS V3 00 00 E1720016 Message 5 MESSAGES Build tool was not found Explanation This appears when the build tool is not found E1720017 Message It is building demanded operation cannot be performed Explanation This appears when a manipulation request is received for a library file during a build Action by User Repeat the command when a build is not being performed E1720018 Message Acquisition of a library file went wrong direct cause Explanation This appears on failure to obtain the library file of link option
240. ssage The project information is invalid Explanation This error occurs when the program fails to parse a file Action by User Specify a project file which can be handled by this product to open E0202012 Message Valid project information cannot be found Explanation This error occurs when the program fails to restore or convert project information It will also occur if the program fails to extract the structure of a project to copy Action by User Specify a project file which can be handled by this product to open E0202013 Message The item information cannot be restored Explanation This error occurs when the program fails to restore or convert project information It will also occur if the program fails to extract the structure of a project to copy Action by User Specify a project file which can be handled by this product to open E0202014 Message The file information cannot be restored Explanation This error occurs when the program fails to restore or convert project information It will also occur if the program fails to extract the structure of a project to copy Action by User Specify a project file which can be handled by this product to open E0202015 Message The category information cannot be restored Explanation This error occurs when the program fails to restore or convert project information It
241. stallation XXX Stop the installation Explanation This appears when the installation of a required environment fails E0140039 Message The following product failed in installation XXX The following products are required to reboot Windows to complete the installation Please reboot your computer XXX Please install the latest service packs and security updates for this product using Windows Update and Microsoft Upadate Stop the installation Explanation This appears when the installation of a required environment fails but when it s necessary to be a restart by the installation which succeeded E0140040 Message The following product failed in installation XXX The following product succeeded in installation XXX Please install the latest service packs and security updates for this product using Windows Update and Microsoft Upadate Stop the installation Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This appears when the installation of a required environment fails but when instal lation besides that succeeded ztENESAS Page 22 of 152 CS V3 00 00 E0140041 Message 5 MESSAGES The following product failed in installation XXX The following products are required to reboot Windows to complete the installation Please reboot your computer XXX The following product succeeded in installation XXX Please insta
242. sts Action by User Make sure the input value is correct E0203023 Message Build in progress Explanation This error occurs when attempting to perform a build when a build is in progress Action by User Wait until the build completes E0203025 Message Number of include paths exceeded the maximum limit xxx Explanation This message appears when the number of include path settings exceeds the max imum when the build starts Action by User Reduce the number of include paths you have added E0203026 Message Number of library paths exceeded the maximum limit xxx Explanation This message appears when the number of library path settings exceeds the maxi mum when the build starts Action by User Reduce the number of include paths you have added E0203027 Message Number of library files exceeded the maximum limit xxx Explanation This message appears when the number of library settings exceeds the maximum when the build starts Action by User Reduce the number of library files used E0203028 Message Any Compiler package xxx using the project is not installed Explanation This appears when there are no compiler packages installed Action by User Make sure that the build tool is correctly installed E0203029 Message IronPython Console Plug in is not installed Action b
243. sure that the debugging tool is connected E0209011 Message Executing a hook process failed xxx yyy Explanation This message appears when a hook process executing failed Action by User Check whether it s without errors in description of hook processing E0210001 Message Quitting debugger failed Explanation This message appears when an exception is thrown while executing the Discon nect Debugger menu command Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Follow the instructions in the message to remedy the problem ztENESAS Page 37 of 152 CS V3 00 00 E0210002 Message 5 MESSAGES Launching debugger failed Explanation This message appears when an exception is thrown while executing the Connect to Debugger menu command Action by User Make sure that the debugging tool is connected E0210003 Message Connection with a debug tool lost Abort debugging Explanation This error appears when the USB connection or emulator power turned off Action by User Check the emulator power Check whether the USB cable isn t cut E0210004 Message Failed to save the result of coverage for reusing Retry Retry saving Cancel Keep disconnection processing Explanation This appears upon failure to save the coverage results Action by User Check the access privileges to the
244. t PC position cannot be performed Action by User Return cannot be executed if the PC is located at other than the start address of a source line an error appears Since it is not at the start address of a source line immediately after executing a return it is not possible to execute returns consecu tively Execute a return after executing a step at the source level so that the PC indicates the start address of the next line E1245109 Message Return out execution from current PC position cannot be performed please exe cute source mode step before return out execution E1245111 Message Too Many Line Numbers Information E1245112 Message Compiler version mismatch E1245113 Message Failed in loading debug information E1245114 Message No more section information E1245120 Message Specified file is not load module E1245121 Message Too many files in load module to download E1245870 Message Illegal port number E1245871 Message Illegal port name E1245872 Message Illegal port position E1245873 Message Illegal increment number E1245874 Message Port for memory bank is not set E1245875 Message Illegal bank number E1245876 Message Area for memory bank is not set E1249153 Message Can not open file E1249154 Message Can not close file E1249155 Message Reading of file went wrong E1249156 Message Reading of file went
245. t access file xxx A file needed to install this product may be missing or damaged Canceling installation Explanation This appears when there are missing components or the information file is corrupt E0140008 Message A file necessary for installing this product was not able to be read and or write Canceling installation Explanation This appears when the Renesas Electronics sales offices information files could not be copied to the host machine E0140009 Message Cannot copy the file xxx required for installation of this product A file with the same name already exists at the copy destination Canceling installation Explanation This appears when the Renesas Electronics sales offices information files could not be copied to the host machine E0140010 Message Cannot obtain information required for installation XXX Explanation This appears when the information required for installation is not set The file may be damaged E0140012 Message Cannot access the license agreement file A file needed to install this product may be missing or damaged Canceling installation E0140013 Message Cannot display the license agreement file The file may be damaged Canceling installation E0140014 Message Cannot obtain information about the destination folder of the previous installation Canceling installation Explanation This appe
246. t finish during the trace recording stop processing ztENESAS Page 54 of 152 CS V3 00 00 E1201432 Message 5 MESSAGES The function to issue a break for peripheral macros was not installed in the MCU and therefore it could not be set E1201435 Message Incorrect ID Code E1201536 Message Not enough memory for buffer E1201537 Message Not enough resource of operating system E1202819 Message Use emulator and a device file are a mismatch E1202820 Message Target power mode mismatch E1202855 Message User data is written to the debug monitor area Before starting please set Yes to Erase flash ROM when starting E1202856 Message On chip Debug Option Byte controlling value is invalid Before starting please set Yes to Erase flash ROM when starting E1202857 Message Can not write the flash memory because the clock frequency is beyond the limits of regulations It may be avoidable by the following setting change or processing change Select the frequency value of the External clock source with a Main clock fre quency property Select the System with a Monitor clock property Change from a system clock to a main clock by SFR rewriting Explanation Flash programming has been stopped because the sub clock is currently selected as the operating clock or the value of Main clock frequency in the debugger e
247. t is possible that the necessary files were not included E0300002 Message Could not load file name to start pin configurator plug in Action by User Make sure that the correct files are included It is possible that a necessary file is corrupt E0300003 Message Could not load the necessary information to start pin configurator plug in Action by User This appears when a project file could not be opened in the same state in which it was saved Check the installation status of CS E0300004 Message The setting of pin No xxx was not changed Explanation When functions are assigned by code generator this message appears if there are differences between the pin information generatod by the code generater and that in the common libraries Action by User Re install the correct file E0400000 Message This function name has been used Please use another one E0400001 Message This file name has been used Please use another one E0400002 Message Invalid function name The function name must be constructed with _ a z A Z 0 9 E0400003 Message Invalid file name The file name must be constructed with _ a z A Z 0 9 E0400004 Message The output path is invalid Please check Generation gt Generate File Mode gt Output folder E0400005 Message Save xxx failed E0600005 Message This function is not supported E0602203 Message Simulator Configuration file not found E0602204 Message The s
248. t is to be created does not exist Explanation This indicates that the specified folder was not found in the project creation loca tion Action by User Specify the existing folder E0222002 Message The project name is invalid Enter characters that can be used as a file name Explanation This appears when the character that cannot be used as a file name is specified for the project name Action by User Specify a different project name E0222003 Message The location for project creation is invalid Enter characters that can be used as a path name Explanation The path specified as the creation location is illegal Action by User Specify a different creation location E0222005 Message Creating project folder xxx failed Explanation Failed to create the specified folder Action by User Follow the instructions in the message to remedy the problem E0222006 Message The divert project does not exist Explanation The specified project is not found Action by User Specify a different project E0222007 Message The divert project name is invalid Enter characters that can be used as a file name Explanation The project name for specified project is invalid Action by User Specify a different project E0222009 Message The project which is being used can t be diverted
249. t option setting memory is not written Action by User To set up the option setting memory start up the emulator and download a file with the required settings W1811126 Message OSF1 register value was modified Explanation This message only appears during debugging Data was modified W1811127 Message MDE register value and OFS1 register value were modified Explanation This message only appears during debugging Data was modified W1811306 Message The read operation to the data flash area where reading was prohibited occurred W1811318 Message The access violation to the internal flash ROM has occurred ILGLERR bit is 1 W1811321 Message Data for MDE register was modified for the endian which was specified on starting up W1811322 Message Data for UB code was modified for the operating mode which was specified on starting up W1811323 Message Data for MDE register and UB code were modified for the setting which was spec ified on starting up W1811325 Message Internal ROM area was accessed while user program is running W1811326 Message The emulator has recovered from a communication error which occurred because the clock was switched during memory access or due to other reasons W1811328 Message The writing data for OFS1 register was modified to disable Startup Voltage Moni toring 1 Reset
250. tallation was suc cessful and the system must therefore be restarted E0140021 Message Some installations have failed The installations of the specified tools are not completed Explanation This appears when there has been a failed installation E0140023 Message Installation failed The installation was aborted before finish Explanation This appears when the installation was aborted and the installation of the com pleted portion before cancelling failed E0140024 Message Could not create a directory necessary for installing this product Installation aborted Explanation This appears when the folder in which to allocate the linking information for other tools could not be created E0140026 Message Could not start xxx Explanation This appears when The Launch Update Manager check box in the Setup com pletion Window is checked and Update Manager failed to start Or this appears when you click Next in the installation window when installing a required environment and the integrated installer fails to launch E0140027 Message The system may not be properly configured for installation Canceling installation Explanation This appears when the registry could not be referenced while checking for installed tools E0140028 Message CS Utilities is already installed Please remove CS Utilities Programs and Features dialog box Canceling installation Explanation The integrated installer has detected that
251. te downloaded file xxx Please retry the operation Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0111100 Message Failed to write internal data Aborting the download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0111101 Message Failed to write internal data because saving destination is not found Aborting the download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0111102 Message Failed to write internal data Aborting the download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0111103 Message Failed to write internal data because denied to write Aborting the download Action by User Please contact your vendor or your Renesas Electronics overseas representative E0111104 Message I O error occurred while downloading a file Action by User Please contact your vendor or your Renesas Electronics overseas representative E0112000 Message The server returned an error xxx Please retry the operation after a while Action by User If this error persists please contact your vendor or your Renesas Electronics over seas representative E0112200 Message The server returned an e
252. tended nor authorized for use in products or systems that may pose a direct threat to human life or bodily injury artificial life support devices or systems surgical implantations etc or may cause serious property damages nuclear reactor control systems military equipment etc You must check the quality grade of each Renesas Electronics product before using it in a particular application You may not use any Renesas Electronics product for any application for which it is not intended Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for which the product is not intended by Renesas Electronics You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges Although Renesas Electronics endeavors to improve the quality and reliability of its products semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions Further Renesas Electronics products
253. ters Action by User Specify a valid filename W0294005 Message The specified value is out of range Explanation A value outside the supported range has been entered in a field for numerical val ues e g for a property setting Action by User Enter a value within the supported range W0300001 Message The name is already used Please use another name Action by User Change to a different name W0300002 Message Only the user defined column can be deleted Action by User Deselect non user defined columns W0300003 Message The column of the same name exists Please input another name Action by User Change the name W0300004 Message Please input the column name W0300005 Message R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Please select a column to delete ztENESAS Page 140 of 152 CS V3 00 00 5 MESSAGES W0300006 Message The external peripheral of the same name exists Please input another name Action by User Change the name of the external peripheral W0300007 Message Please input the external peripheral name W0300008 Message The input value does not correspond to the type of the column Please input a cor rect value Action by User Change the value W0403000 Message Code generation failed W0403001 Message The following pin conflicts have bee
254. the condition here when the condition is one Explanation The Condition 1 combo box is empty and the Condition 2 combo box is not E0826001 Message Failed to save the image because the image size is too huge Explanation A limitation of the Microsoft NET Framework and GDI images with a size of greater than 2 gigabytes in memory cannot be created has been reached Action by User Use the Visible region only save command E0827001 Message Executing program Explanation A search was executed during program execution Action by User Perform searches while the program is halted E1200002 Message This feature is not supported E1200256 Message Can not communicate with Emulator Please confirm the installation of the device driver for the PC interface board E1200257 Message Can not find initialization file expc ini E1200258 Message Host name not found E1200259 Message Data transfer to Emulator is timed out Please confirm the power of Emulator con nection of the interface cable or I O address of the PC interface board E1200260 Message Data receive from Emulator is timed out Please confirm the power of Emulator connection of the interface cable or I O address of the PC interface board E1200261 Message Failed in reading device dependent information file E1200262 Messa
255. the output formats of messages The output format when CS is operated is as follows 1 When the file name and line number are included file name line number message type component number message number messag 2 When the file name and line number aren t included message type component number message number messag Remark Following contents are output as the continued character string MESSAGE TYPES 1 alphabetic character COMPONENT NUMBERS 2 digits MESSAGE NUMBERS 5 digits R20UT3099EJ0100 Rev 1 00 tENESAS Page 6 of 152 Aug 01 2014 CS V3 00 00 3 MESSAGE TYPES 3 MESSAGE TYPES This chapter describes the message types displayed by CS The message types 1 alphabetic character when CS is operated are as follows Table 3 1 Message Type Message Type Description Internal error Processing terminated suspended due to internal error Fatal error Processing terminated Suspended due to fatal error Information Informational message Check the message and continue the process Choice This type of message is displayed when a choice is necessary in order to carry on with the next operation It performs the selected action Warning Warning message Check the message and continue the process R20UT3099EJ0100 Rev 1 00 ztENESAS Page 7 of 152 Aug 01 2014 CS V3 00 00 4 COMPONENT NUMBERS 4 COMPONENT NUMBERS This chapter describes the component numbe
256. ting a batch clean from the Batch Build dialog box Action by User Make sure that the build tool exists E0203008 Message Setting build mode failed Explanation This message appears when an error occurs in the Build Mode Settings dialog box Action by User Make sure the input value is correct E0203009 Message Displaying build options list failed Explanation This message appears when the program fails to show the build options list Action by User Make sure that the build tool is installed E0203010 Message Updating dependency failed Explanation This message appears when the program fails to update the file dependencies Action by User Check the access privileges to the file Make sure that there are no invalid paths in the C source E0203011 Message Setting link order failed Explanation This message appears when the program fails to set the link order Action by User Make sure that there are no errors in the link order specification E0203012 Message Assembling failed Explanation This error occurs when a command could not be executed Action by User Follow the instructions in the message to remedy the problem E0203013 Message Compiling failed Explanation This error occurs when a command could not be executed Action by User Follow the instructio
257. tions tab will change the file extension of the output file Action by User Yes Change the output file extension No Do not change the output file extension Q0291002 Message The folder already contains the following file s XXX Would you like to change the existing files to bak Note In the case of Yes if bak files already exist they will be overwritten Explanation This message appears when file of the same name as a startup program created when project is created already exists at the project creating folder Action by User Yes Change the existing files to bak and create new files No Overwite the existing files Q0293001 Message You are setting the Level3 Inter module optimization The individual compiler assembler option becomes invalid by level 3 The object library files you registered also becomes invalid once And the libraries added in the Using libraries property are removed See the All Messages tab in the Output panel Continue the setting Explanation This appears when you have selected whole program optimization Xwhole_program in build properties to confirm whether you really want to select this option Action by User Yes This disables individual options removes user registered obj and lib files from the project and enables Xwhole_program No This restores the property selections clearing the Xwhole_program option
258. ts xxx that is able to be registered in the project were exceeded Explanation This message appears when the maximum number of subprojects is exceeded while subprojects are being added to the project Action by User Delete unnecessary subprojects from the project in order to reduce the total num ber of subprojects E0202072 Message This is not a convertible e studio project file Explanation This message appears when an attempt is made to convert the rcpc file of a non supported version or e studio Action by User Only specify projects files that can be handled by CS E0202073 Message The last opened project has not been found xxx Explanation This message appears when the most recently opened project was not found if you have made the setting for automatic loading of the most recently opened proj ect during the process of starting up CS Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Manually open the desired project ztENESAS Page 31 of 152 CS V3 00 00 E0202074 Message 5 MESSAGES Failed to restore settings from the file xxx The file can be corrupted or opened by other process Abort Abort launching this application Retry Check whether it can restore settings again Ignore Initialize settings and continue launching Explanation When reading information for each user in the PC has failed
259. tually exclusive Explanation This appears when the bb bc ocb or or options were specified at the same time Action by User Do not specify the bb bc bcb or br options at the same time E0218005 Message Command line option xxx was able to specify yyy parameters Explanation This appears when more than the maximum number of parameters has been spec ified for an option Action by User Specify an allowable number of parameters E0218006 Message Specify valid project file Explanation This appears when no project file was specified when launched from the command line Action by User Specify a valid project file E0218007 Message Command line option xxx was not able to specify in yyy Explanation This appears when an option that cannot be used in GUI mode was specified when starting GUI mode from the command line Action by User Do not specify invalid options when starting GUI mode from the command line E0218001 Message A non existing build mode was specified Explanation This error appears when the IDE is launched via a command Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a build mode defined by the project ztENESAS Page 39 of 152 CS V3 00 00 E0218002 Message 5 MESSAGES Illegal command line options were specified Explanation This ap
260. uded herein Renesas Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document No license express implied or otherwise is granted hereby under any patents copyrights or other intellectual property rights of Renesas Electronics or others You should not alter modify copy or otherwise misappropriate any Renesas Electronics product whether in whole or in part Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from such alteration modification copy or otherwise misappropriation of Renesas Electronics product Renesas Electronics products are classified according to the following two quality grades Standard and High Quality The recommended applications for each Renesas Electronics product depends on the product s quality grade as indicated below Standard Computers office equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots etc High Quality Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems and safety equipment etc Renesas Electronics products are neither in
261. was created by an earlier version of HEW Please open it in HEW 4 07 00 or newer save the project and try again Explanation This appears when the session version is older than HEW 4 07 00 Action by User Open the project with HEW 4 07 00 or a later version save it and convert it again E0292027 Message Project xxx cannot be converted The project is invalid Explanation The project file is invalid Action by User Specify a valid project E0292028 Message XXX was not found Explanation Workspace name is invalid Action by User Specify a valid workspace E0292029 Message Workspace xxx cannot be converted The workspace was created by an earlier version of HEW Please open it in HEW 4 07 00 or newer save the workspace and try again Explanation This appears when the workspace version is older than HEW 4 07 00 Action by User Open the project with HEW 4 07 00 or a later version save it and convert it again E0292030 Message All of the session files referenced in project name were missing or saved by an ear lier version of HEW Please open it in HEW 4 07 00 or newer save the project and try again Explanation All of the hsf files in the project were missing or were saved by an earlier version of HEW Action by User Obtain a workspace that includes the hwp file If this is not possible open the work
262. will also occur if the program fails to extract the structure of a project to copy Action by User R20UT3099EJ0100 Rev 1 00 Aug 01 2014 Specify a project file which can be handled by this product to open ztENESAS Page 26 of 152 CS V3 00 00 E0202016 Message 5 MESSAGES A subproject with the same ID has already been registered Explanation This error occurs when attempting to add a sub project with the same ID Action by User It is not possible to add sub projects with the same ID Create a new sub project copying from the sub project file you wish to add E0202017 Message Saving build options failed Explanation Failed to save build options to the project file Action by User Check the version of the project file E0202018 Message Restoring build options failed Explanation Failed to restore build options from the project file Action by User Check the version of the project file E0202019 Message Saving general options failed Explanation Failed to save common options to the project file Action by User Check the version of the project file E0202020 Message Restoring general options failed Explanation Failed to restore common options from the project file Action by User Check the version of the project file E 0202021 Message Saving compile o
263. xceeds the limit RL78 OCD E1202913 Message Section Trace event conditions overflow E1202918 Message Cannot use the break before execution event and the software break at the same time E1202976 Message FPGA data file was not found E1202977 Message The smaller FPGA data version of the emulator version E1202978 Message The larger FPGA data version of the emulator version E1202979 Message Version of the specified FPGA data was not found E1202980 Message Failed in initializing FPGA or failed in writing FPGA data E1202981 Message Use emulator and a transfer of flash firmware version are a mismatch E1203072 Message Monitor file read error E1203073 Message During access of register CPU did timeout E1203074 Message During access of memory CPU did timeout E1203075 Message During access of I O register CPU did timeout E1203076 Message Flash memory information file was not found or failed in reading the file E1203077 Message Failed in updating monitor code E1203102 Message There is no instruction code necessary of pseudo emulation for the flash self pro gramming function E1203103 Message Rewriting security ID code directly is prohibited E1203104 Message Guarded area can not be accessed E1203105 Message Memory was u
264. y User Check whether the IronPython Console plug in is installed E0204001 Message Download failed Explanation This error appears when an error has occurred while performing a download Action by User Make sure that the debugging tool is connected Check the memory mapping E0205002 Message Editing could not be done Explanation R20UT3099EJ0100 Rev 1 00 Aug 01 2014 This error occurs when the edit action fails for some reason ztENESAS Page 34 of 152 CS V3 00 00 E0205003 Message 5 MESSAGES Searching or replacing failed Explanation This error occurs when the search or replace action fails for some reason Action by User There may not be enough memory E0205004 Message Searching or replacing xxx failed Explanation This error occurs when the search or replace action fails for some reason Action by User There may not be enough memory E0206001 Message Search in progress The next search cannot be done until the current search fin ishes Explanation This message appears when attempting to perform a search while one is in prog ress Action by User Cancel the search or wait until it completes E0207001 Message Writing to memory failed Explanation An error occurred in the debugging tool when writing data to memory Action by User Make sure that t
265. y the symbol in the Disassemble panel W0241001 Message The trace number cannot be omitted Explanation This message appears when saving trace data in the Data Save dialog box and the Save button is clicked while the trace number field is left blank Action by User Enter a trace number in the field W0241002 Message Enter a decimal value for the trace number Explanation This message appears when saving trace data in the Data Save dialog box and the Save button is clicked while a value other than a decimal number is in the trace number field Action by User Specify a decimal number in the trace number field W0241003 Message A trace number equal to or greater than the maximum trace number xxx has been specified Explanation This message appears when saving trace data in the Data Save dialog box and the Save button is clicked while a value greater than the maximum trace number is is in the trace number field Action by User Specify a number no larger than the maximum trace number in the trace number field W0242001 Message The upper limit 128 of watch expressions that can be registered to the Watch panel has been exceeded Explanation The maximum number of watch expressions that can be registered in a single Watch panel is 128 Action by User Remove unnecessary watch expressions or register it in a new Watch panel
Download Pdf Manuals
Related Search
Related Contents
HI-D8PS別冊「緊急通報システム」編 Microlab F.A.M.E. - Frank`s Hospital Workshop PS600 Digital Visualizer Manuale utente User Manual IDK-1110P-series User's Manual - Airis Support Read all safety instructions for safe and effective use Manuel Utilisateur Tecumseh AEA2413YXA Drawing Data 2. Selection of TOP, External device Copyright © All rights reserved.