1. the screws using a cross head screwdriver Test button N Detection lens Alignment arrow Test LED indicator lamp behind Removable tab lens Guarantee sticker Remove the pre cut part of the sticker and stick it to the guarantee certificate in the user manual supplied with the control Locking screw panel If you are adding the siren to an existing system use the guarantee ll sticker provided with this product Oe B p 3 Programming IMPORTANT during recognition programming the product to be programmed for use with the control panel does not need to be placed next to it In fact we recommend you place the product at a short distance from the control panel at least 2 meters away Programming enables the detector to be recognised by the control panel 1 To programme the detector the control panel must be in installation mode If it is not ask the user to press 2 then 3 L beep installation master code engineer installer code mode 0000 by default 1111 by default 2 Programme the device as follows beep detector X detector X time delay group Y immediate or delayed or combined D 10 s max according to the type of control panel Press then on Press and hold the test The control panel waits Choose the type of tr
2. bracket fixing pin n 0 is already factory positioned inside the detector 1 Hold the back plate against the wall in the desired position and mark where to drill the holes 2 Drill the holes in the wall Pictogram e 3 Insert the long screw via the back plate and fasten the plate to the wall Sw 4 Put the back plate cover in place 5 Assemble both parts of the swivel Pozidriv 1 6 Insert the mounted swivel into the long screw 7 Position the base of the motion detector a picture of a man shows the top of the detector 8 Tighten the screws lightly in order to be able to adjust the direction of the motion detector 9 Place the motion detector on its base and turn it so that it is facing the right way Pin n O for swivel bracket fixing factory mounted pin IMPORTANT when fixing the movement detector at an angle or flat against the wall fix the label provided in the sachet of accessories on the reverse side of the product in order to cover the opening to avoid insects getting through Si fixation en angle ou a plat contre un mur For a fixing in a corner or flat against the wall e Fixing the detector flat against the wall 1 Drill through the two pre drilling holes in the base of the motion detector Pre drilled holes 2 Place the base against the wall in the desired place in order to mark where to drill the holes a picture of a man indicates the top of the base 3 Dril
3. shall not be held responsible for any problems Touching the detector s internal parts and or electronic components can damage the product Furthermore the detector is designed in such a way that these parts and components do not need to be accessed for operation or maintenance purposes 1 Introduction The infrared detector is used for protection inside buildings Intruders are detected when the infrared radiation associated with movement varies The detector also detects freezing temperatures based on a thermostatic principle a technical alarm is triggered when the temperature drops below 5 C e 171 21X 175 21X motion detector 172 21X corridor detector 9 fields 173 21X curtain detector 9 fields 19 fields of view 12 m 90 is of view 22 m 12 is designed for of view 12 m 8 is designed for the designed to protect rooms at risk unavoidable passageways and can protection of large surfaces plate lounge main bedroom etc be placed facing the entry point to glass windows garage doors etc be protected Wa fT ies detection zone 2 2m i 7 PS S 1 interruption WIES YI A J Vj NA detect 1 Ho A ae ae E 0 2 4 6 8 10 12 14 16 18 20 22 7 8 9 10 11 12 ji IA i 2 interruption WZ EE i Pi ZA rene 0 4 8 12m 2 20 0 5 10 15 20 22 0123 45 67 8 9 101112 l pe 2 1 Opening 2 2 Power supply Open the detector casing by loosening Connect the lithium battery pack according to the arrow
4. 7 e in such a way that the area it protects does not overlap RIGUT WRONG with that of another motion detector The motion detector must not be placed e in an area likely to receive direct sunlight or a very powerful light source gee e opposite or above a source of heat e outside or in a breezy place e directly on to a metal wall or close to sources of lt interference electricity meters etc or ventilation such as RIGHT air conditioning grilles b 5 2 Fixing method IMPORTANT for reasons of security and to ensure long battery life installation of the anti tamper pin is compulsory In case of omission or incorrect insertion of the pin the detector LED indicator lamp flashes continuously when the detector is fitted to its bracket The detector can be fixed to a wall in 3 ways e on a swivel bracket e flat against the wall Order in which to assemble parts e in a corner amp raa l sa jp E Pin n 1 f 5 P There is an anti tamper pin for each a a type of fixing method ig e swivel bracket pin n O pm y e flat pin n 1 Base L Pin n 2 e in a corner n 2 Z L l h j Screw i _ Swivel tightening Long screw washer Selection of pins Back plate Back plate cover e Fixing the detector on a swivel bracket IMPORTANT for swivel
5. Infrared motion detector GM chron 171 21X 172 21X 173 21X 175 21X INSTALLATION MANUAL DAITEM Summary AO TEVERO GUC WOM TEn E E E E E E E E 2 2o Prepara ON o aaea Ea aa AA A E E E A EE a EA A E A E 2 2 KOPeEnInN a a E e a a a eer ecueneeys 2 Ze POW Cle SUDOV E a E R sae T E T E E anaes 2 3 Progra mMM eeaeee aaaea ae aAa aeaee E E A E E Aea AE A E a A a 3 A Loa Lie EL 109 8 e a a e E E E a nacrnn ey Serer rer esmtarse 4 DNS AMIMIG MC CCC CUON seecrc cence E acts remote caren ennr Meets ecean ee tes teaee antec ereceere ras sn reece yee 5 De ChOOSING the DEST PlACC ee Ta e a Sea eeceeeceeeneatsseumenes cee ate mean remnt se se he element E E Lene tree teedaiss 5 SAPNO Meno d ae mes a a cer ory terres crter recy ere trey oererr rns Pree reser Die ener ene erect areca sore raeerree etarrer mace eaahene ier 5 SG Direcing ana testing ine detoctOn Taa mea are e E a E E E E S e e E E 6 Ge MamtenanhC e oaeee ea E aE E aE A EA E A EE tarereetee 7 6 BIREW NACION e E a E cnet ence A a ere wee ieee ei 7 6 27ChanGing the Date arcsec cuca atnens E taanisaticaevn norer aradeexer tame cnecocientrntinnyaadresen a ever sex 7 Te CCIM GL CaCl cccccresesscccntecetccccsscsrteceeensiisctvetececccscscassiverecceca sccaestacccers E 7 Recommendations The user must not attempt to access the detector s internal parts except areas described in this manual If the user does access these parts the product guarantee will be considered null and void and DAITEM
6. TY Manufacturer Hager Security SAS 12 Address F 38926 Crolles Cedex France Product type Motion detector Trade mark Daitem We declare under our sole responsibility that the products to which this declaration relates are thus compliant with the essential requirements of the following European Directives e R amp TTE Directive 99 5 CE e Low Voltage Directive 2006 95 CE e ROHS Directive 2002 95 CE in compliance with the following harmonised European Standards EN 300 330 2 V131 Jo EN 55022 amp 55024 2002 EN 301 489 1 V1 8 1 These products can be used in all EU EEA Countries and Switzerland Er ine ae ie X Crolles 31 08 2012 Signature Patrick Bernard Research amp Development Manager Non binding document subject to modification without notice a DAITEM Nu 805153 A 10 2012
7. d or combined Checking the detection area e press on the test button the detector switches to test mode for a period of 90sec e walk across the detection area at right angles to the detector s fields of view see diagram every time movement is detected the detector test LED indicator lamp lights up If no movement is detected change the way the detector is facing on its swivel bracket check there is no obstacle between the detection area and the detector 171 21X 175 21X 172 21X 173 21X veo Re ah ee IMPORTANT at the end of the test period the detector automatically switches back to normal operating mode e detector inhibited for 90 sec after detection e the test LED indicator lamp is no longer lit when movement is detected 6 1 Battery low indication The control panel indicates when the infrared detector s battery is low To check whether there is a problem with the detector battery press on the detector s test button IMPORTANT if the test LED indicator lamp no longer lights up the lithium battery should be replaced 6 2 Changing the battery e The lithium battery pack must be replaced by the same type of pack with the same technical characteristics BATLi25 2 x 3 6 V 2 Ah e We advise you to use the DAITEM BatLi25 pack available in the catalogue in order to guarantee individual safety and equipment reliability e Dispose of the waste lithium power pack in a
8. iggering The control panel the control panel button until the control for a group to be chosen 0 immediate gives a voice keypad panel responds from 1 to 8 Choose the 1 delayed message to confirm group by pressing the 2 combined corresponding numeral on the Use the control panel keypad control panel keypad to select the type IMPORTANT the control panel indicates there is an error by emitting 3 short beeps When this happens programming should be carried out again e Example programming of 1st detector allocated to Gr 2 with immediate triggering beep detector detector 1 time delay 1 group 2 immediate IMPORTANT the control panel indicates there is an error by emitting 3 short beeps When this happens programming should be carried out again 4 Configuration IMPORTANT The casing must be open when configuring the detector e Detection parameter selection Choice aie aa Parameter Technical data of function Detection sensitivity 1 edge triggering not recommended for detector 171 21X 175 21X B 2 edge triggering factory setting Ramanan for interior using detector 171 21X 175 21X Alarm level Intrusion factory setting Le Prealert Deterrence Warning a detection Disabled factory setting a 3 Enabled e Follow the configuration sequence described below about 10 sec about 2 sec To start the sequence Press 1 4 or 7 times Pres
9. l the holes in the wall and fix the base Ge 2 fixing pe screws 4 Remove the factory positioned pin 5 Detach pin n 1 from the selection supplied 6 Position the pin in the right place 7 Place the motion detector on its base e Fixing the detector in a corner 1 Drill through the two pre drilling holes in the base of the detector 2 Place the base against the wall in the desired place in order to mark E where to drill the holes a picture of a man indicates the top of the base 2 3 Drill the holes in the wall and fix the base 4 Remove the factory positioned pin 5 Detach pin n 2 from the selection supplied 6 Position the pin in the right place 7 Place the motion detector on its base 5 3 Directing and testing the detector Pozidriv 1 Pin n 1 for fixing the detector flat against the wall Pre drilled holes 2 fixing Screws Pictogram Pozidriv 1 Pin n 2 for fixing the detector a4 in a corner i IMPORTANT the control panel must be in installation mode to check the above The infrared detector has a test mode for checking e the power supply the LED indicator lamp lights up when you press the test button to confirm the battery is operating correctly e the detection area the LED indicator lamp lights up on detection e the radio link See on checking the radio link in the control panel manual beep detector X group Y immediate or delaye
10. n appropriate recycling bin To change the battery 1 Switch the control panel to installation mode and ask the user to press 2 then Ol IL beep installation master code engineer installer code mode The detector s configuration is saved when the battery is changed 2 Open the detector casing see on Opening 3 Unclip the lithium battery pack 4 Wait 2 min before replacing the flat lithium battery 5 Close the detector 6 Switch the control panel back to user mode Press 1 J IL engineer installer code time off beep Cate 7 lechnical data Specifications Infrared detection e 171 21X 175 21X 12 m 90 motion detector e 172 21X 22 m 12 corridor detector e 173 21X 12 m 8 curtain detector Fixing methods e on a swivel bracket e flat against the wall e in a corner Use Power supply 2 x 3 6 V 2 Ah BatLi25 lithium battery Battery life 5 years in normal conditions of use Average humidity rate 5 to 75 without condensation at 25 C Radio links TwinBand 400 800 MHz Test button LED indicator lamp Operating temperature Protection mechanism Degrees of mechanical protection Dimensions without swivel bracket 115 g with battery swivel bracket and base C DECLARATION OF CONFORMI
11. s and hold Press 1 to 4 times To end the sequence LED indicator press and hold the depending on the until the LED depending on the press and hold the button lamp lit button until the LED required parameter indicator lamp required parameter until the LED indicator correct indicator lamp goes out number briefly goes out value lamp goes out configuration Configuration example setting the detector for an alarm level when a full prealert is triggered Parameter n 4 Parameter value 2 Press 4 times to select Press once to Press 2 times Press and hold until the the alarm level accept selection to select LED goes out to finish the prealert level Checking configuration check the alarm level by selecting the Parameter N and checking the number of corresponding flashes es i b Sa L s ld PS s ra a I r r Press 4 times to select Press once to 2 flashes confirm the alarm level accept selection that the device is set for a prealert 5 Installing the detector 5 1 Choosing the best place IMPORTANT make sure there is a distance of at least 2 meters between each product except between two detectors The motion detector must be placed e inside the building e 2 20 m above ground level se e at right angles to the entrances to be protected interior detection works best when the intruder walks across the a D 4 detector s fields of view e directed towards the inside of the room to be protected