1. FIRE FAULT DISABLED TEST JSupPEy SYSTEM FAULT SUPPLY FAULT BATTERY FAULT AUX SUPPLY FAULT EARTH FAULT FIRE 4 5 TEST FAULT DISABLED INSTRUCTIONS FOR CONVENTIONAL FIRE ALARM PANEL ORTON General User Access Level 1 To silence internal buzzer press BUZZER SILENCE To override active delays during an alarm condition press DELAYS ACTIVE Authorized User Access Level 2 To enter this level enter 4 digit code Consult Manual for more details EVACUATION Enter Authorised User Code Access Level 2 Press SOUNDER Activate Silence Repeat last step to SILENCE sounders A GLOBAL gt FIRE EQUIPMENT Fire Events Internal Buzzer sounds System Status Fire LED is lit Zones on Fire will have their respective Fire LED lit To silence fire alarms First enter authorised user code Access Level 2 Press SOUNDER Activate Silence button Fault Events Internal Buzzer Sounds System Status Fault LED is lit Each fault will be shown by its own LED being lit Call service engineer MANUFACTURED IN THE E U TO THE REQUIREMENTS OF EN54 Pt 2 amp Pt 4 1999 2 4 8 Zone Fire Alarm Control Panel Operating Manual CONTROLS BUZZER SILENCE LAMP TEST 3 SOUNDERS ACTIVATE SILENCE OUTPUTS AUXILIARY DISABLE SOUNDERS SELECTED ZONES DELAYS ACTIVE ORION GLOBAL FIRE EQUIPMENT The Panel Buttons STATUS T T one CONTROLS Ore FRE BUZZE
2. R SILENCE 4 5 TEST FAULT C N O DISABLED DISABLED Desn LAMP TEST SUPPLY SOUNDERS ACTIVATE SYSTEM FAULT SILENCE FAULTS INSTRUCTIONS FOR CONVENTIONAL FIRE ALARM PANEL COVROUN General User Access Level 1 Fire Events SUPPLY FAULT To silence internal buzzer press BUZZER SILENCE Internal Buzzer sounds To override active delays during an alarm condition System Status Fire LED is lit press DELAYS ACTIVE Zones on Fire will have their respective Fire LED lit To silence fire alarms Authorized User Access Level 2 First enter authorised user code Access Level 2 BATTERY FAULT To enter this level enter 4 digit code Press SOUNDER Activate Silence button Consult Manual for more details Fault Events EVACUATION Internal Buzzer Sounds AUX SUPPLY FAULT Enter Authorised User Code Access Level 2 System Status Fault LED is lit Press SOUNDER Activate Silence Each fault will be shown by its own LED being lit Repeat last step to SILENCE sounders Call service engineer DELAYS G Eo B A L ACTIVE MANUFACTURED IN THE E U TO THE PUSE OURAL REQUIREMENTS OF EN54 Pt 2 amp Pt 4 1999 EARTH FAULT Fire LED used to indicate any FIRE ALARM condition present on panel Fault LED used to indicate any FAULT condition present on panel Disabled Disabled Status LED used to indicate that the panel has features that have been disabled in either Access Level 2 or 3 modes Test This LED is
3. abled then its FAULT LED will also be used to indicate the disablement of that particular zone The Zone LED will be ON along with the Disabled status LED Flashing Zone Fault LED along with General fault LED indicates fault on that zone CONTROLS These four keys can have more than one function They are numbered to indicate that they are used to enter digits from 1 to 4 for code entry BUZZER SILENCE 1 AtAccess Level 1 this button is used to silence the panel s internal buzzer Access level 3 used to confirm accept changes in programming RESET 2 Press this button to reset the panel at access level 2 or 3 LAMP TEST 3 Press this button at access level 1 or 2 to test all LED indicators and the panel s internal buzzer Release when test is finished SOUNDERS 4 Press once to activate silence sounders If sounders are active for example during a FIRE condition or in the event of an Evacuation action pressing this button will stop the sounders Auxiliary Relays are not affected by this action Used in Access level 3 programming to select Zones DISABLEMENTS These buttons are only active at access levels 2 or 3 Installation Operating and Maintenance ManualVersion 1 0 Sep 28 2005 ORION 2 4 8 Zone Fire Alarm Control Panel p ORION GLOBAL FIRE EQUIPMENT They can perform different functions depending on the present panel mode of operation AtAccess Level 2 USER MODE These buttons have a toggle acti
4. active whenever panel is in TEST MODE Only LIT when in Engineering Mode and TEST mode has been selected Multi function indicator used to indicate the presence of supply When in Access Level 1 this LED is permanently lit If in Access Level 2 enter this mode using USER CODE this LED will flash at a rate of once per second And finally if in Access Level 3 mode enter using ENGINEERING CODE this LED will flash faster at a rate of once every 0 5 seconds System FaultThis LED will be lit whenever there is a processor failure or corruption of the panel firmware Installation Operating and Maintenance ManualVersion 1 0 Sep 28 2005 ORION 2 4 8 Zone Fire Alarm Control Panel p ORION GEOR at FAULTS Supply Fault This LED will be ON whenever the Main Supply has been removed or has dropped below 20 Volts Battery Fault Indicates that there is low voltage level on the batteries or the battery charger circuit has failed Aux Supply Fault Indicates that the Auxiliary Supply has a fault Earth Fault When this indicator is ON there is leakage current flowing from the earth connection wiring and any conductor in coming into the panel Sounder Fault If there is a conventional sounder circuit fault the General Fault LED will be lit and the Disable Sounders LED in the disablements section will also be lit and flashing Zone Indicators Individual zone indicators are provided for both FIRE and FAULT conditions If any zone is dis
5. l Panel po ORION GLOBAL FIRE EQUIPMENT Troubleshooting Fault Indications Troubleshooting work of any fault on the panel should only be carried out by qualified technicians General Fault The General fault LED is illuminated whenever there is a fault on the system It is always lit along with at least one other fault indicator which gives more detail relating to the fault Zone Fault This type of fault will indicate that there is either a short or open circuit condition on zone circuit Revise wiring Power Supply Faults Supply Fault Associated with a low voltage below 20 V present at the input of the power supply or the removal of the main power supply Measure voltage levels and verify electrical mains fuse Battery Fault This fault is present when there is a low voltage below 20 V DC at the battery terminals or if there is a battery charger problem Charger problems can be caused by panel s hardware failure or batteries that have not been connected in the specified manner as indicated in this manual on the installation section Verify if batteries are properly connected Measure the voltage at the battery terminals If it is below 21V DC replace batteries Remember to verify also the main electrical fuse DON T EVER SHORT CIRCUIT BATTERY TERMINALS IN ORDER TO VERIFY BATTERY CHARGE ONLY USE BATTERIES WHICH ARE LEAD ACID VRLA TYPE 12 VDC Aux Supply Fault This fault will show when the voltage at the auxiliary supply
6. on One press will disable the particular feature being selected another press of the same actuator will re enable the function When a particular function is disabled its associated LED will be active and OFF otherwise OUTPUTS AUXILIARY Pressing this button will ENABLE DISABLE the auxiliary relays DISABLE SOUNDERS The user can use this button to enable disable the conventional sounder circuits Note Disables both sounder circuits SELECTED ZONES Use this button to select the zone disablement feature Press once associated LED will light up and by using the GREEN 1 button select the zone to be disabled Selected zone will have its FAULT DISABLED LED ON Confirm selection by pressing RED 4 button Zone Disablements will only be active after RESET Once the disablement procedure is finished press again this button to exit DELAYS ACTIVE Pressing this button will enable the previously programmed delay Day Night The corresponding LED will be ON during this time In access level 1 during the delay time which started due to a FIRE alarm pressing this button over rides the delay timer and the sounders and Fire relay will be activated immediately For information regarding special functions associated with these buttons in access level 3 Engineering Mode please consult the Programming section of this manual Installation Operating and Maintenance ManualVersion 1 0 Sep 28 2005 ORION 2 4 8 Zone Fire Alarm Contro
7. output is below 20 Volts DC This can be caused by the current limit for this output being exceeded This output is limited to 300 mA Other causes for faults on this point are short circuits on the wiring or faulty hardware attached to this supply output Verify voltage if below the required acceptable level remove wiring connected to this output If voltage now returns to normal this confirms that connected equipment or cable is damaged Earth Fault This FAULT will indicate that there is some level of current leakage between any of the wire conductors and the EARTH connections VERIFY WIRING System Fault This FAULT indicates that there is a fault at the main processor level In this particular fault the panel s main board needs to be replaced or repaired Installation Operating and Maintenance ManualVersion 1 0 Sep 28 2005 ORION 2 4 8 Zone Fire Alarm Control Panel
Download Pdf Manuals
Related Search
Related Contents
buenas prácticas fitosanitarias en áreas verdes y zonas no agrícolas Polar Cyclometer FI-90440 User's Manual Samsung L74W Manual de Usuario actualizaciones del software del sistema Taylor 1478 Paradise RA 5785 User's Manual launcher progressive nitrous controller 2 MB 14th Feb 2014 NVRX Quick Start Guide USER`S MANUAL FOR EW Copyright © All rights reserved.