1. Usage 8 Disinfection and cleaning 8 1 Disinfect and clean the hose manifold together with the complete suction system For reasons of hygiene and perfect function after every patient treatment e Aspirate a glass of cold water through the large and the small suction hoses Carry out this even when for example only the small suction hose was actually used during treat ment Aspiration using the larger suction hose i allows a greater amount of fresh air to be drawn up and this increases consid erably the cleaning efficiency After completing treatment Disinfect and clean the suction system after treatment is completed and where greater patient loads are experienced 2 x day midday and evening For the disinfection and cleaning of the i complete suction system Comfort hose manifold suction hoses amalgam sep arator suction unit use a non aggres sive non foaming disinfection and cleaning agent approved and released by D rr Dental e g Orotol plus To aspirate the disinfection and cleaning agent a care system using a suction hose adapter should be used e g Oro Cup Suction from a beaker or another vessel without using a suitable adapter is not appropriate for disinfection and clean ing e As pretreatment suck up 2 liters of water through the system using the system OroCup e Preparing the solution For a single treatment unit 20 ml 1 cap full Oro
2. Unplug at the mains and remove all NS power Wear protective gloves a Only use once R Part type B 1 2 Notes on copyright All circuits processes names software and ap pliances quoted are protected under industrial property rights Any reprinting of the technical documentation in whole or in part is subject to prior approval of D rr Dental being given in writing 9000 606 18 30 1210V002 o Important information 0 2 Safety D rr Dental has designed and constructed this appliance so that when used correctly there is no danger to people or property Nevertheless there are residual risks Please follow the in structions below carefully 2 1 Correct use The D rr Dental Comfort Hose Manifold is part of a dental suction system designed for intraoral aspiration during dental medical applications Suction hoses can be hung in place in the Com fort hose manifold when not being used even with the cannula fitted in position On hanging a suction hose into its holder an electrical signal switches off the suction unit On removing a suction hose from its holder an electrical signal automatically switches on the suction unit The Comfort hose manifold with its suction hos es and handpieces is suitable for both wet and dry suction systems The Comfort hose mani fold has been designed as a modular system The number of modules can be expanded as re quired 2 2 Incorrect use Any use of this applianc
3. Rinsing hose PVC 3 x 1 5 x 6 mm Disposable filter yellow 12 pieces Universal cannula set 2 pieces Drill template Swivel joint Rotating collar 16 mm Hose manifold installation set Saliva cannula Installation and Operating Instructions Four fold hose manifold Comfort Type KGFG 7604G03 Small suction handpiece Large suction handpiece Rinsing hose PVC 3 x 1 5 x 6 mm Large suction hose 160 cm Small suction hose 160 cm Central suction hose Disposable filter yellow 12 pieces Universal cannula set 2 pieces Drill template Swivel joint Rotating cover 16 mm Hose manifold installation set Saliva cannula Installation and Operating Instructions Product description Five fold hose manifold Comfort Type SGFKK 7605G51 The five fold hose manifold Comfort can be configured to meet any requirements 3 3 Accessories An overview of D rr Dental suction i handpieces swivel joints rotating cov ers adapters and cannula can be found in the information leaflet supplied Cleaning and Disinfection of Suction Handpieces Order number 9000 606 16 01 or in our download area under www duerr de 3 4 Special accessories When ordering the order number must i be completed by substituting by either the letter A grey or S black Example 7
4. where necessary O eZ d 4 6 6 Electrical connection Connect the rinse hose and lay correctly NOTICE e Slide off the blue covering cap and slide the A Fault due to cable being laid under mechanical tension e Avoid mechanical strain when laying cable e Lay the cable parallel to the central suction hose and to rinse hose and connect to the floor socket e Clip the hose to the central suction hose e Lay the rinsing unit hose ensuring as far as possible that it is parallel to the central suction hose 9000 606 18 30 1210V002 17 H Mounting Example of connection A Comfort Hose Manifold B Station selector switch C Control box e g 0732 or 0700 Connection in filter element m q gt a OOO on DOOD OD S gt 18 6 7 Place panel in position e Place front panel in position again noting se quence 1 Slide the cover under the edge 2 and 3 Snap clipse in place 6 8 Position and fit out suction hoses e Connect suction hose or suction hoses Fit out suction hoses depending on variant and according to needs e g e Large suction hose fitted with swivel joint large suction handpiece rotating collar and universal cannula e Small suction handpiece fitted with small suc tion handp
5. 600A010 50 for grey or 7600S010 50 for black The following are optional and can be used with the unit large suction hose MODEM ur Ena deeper can 76002010 50 large suction hose VAS CM 4e oa rar rek var vann 76007010 51 small suction hose TEO N L a ardea ad stamde 7600 020 50 small suction hose VAS CM osha downs ved eaten 76007020 51 central suction hose 7600 350 00 saliva cannula fits large suction handpiece 7068 003 05 swivel arm 7600G150 00 filter cover for disposable filter yellow 1 piece 0725 041 03 adapter plate for triple hose manifold LC PE PP 7600 163 01 adapter plate for four fold hose manifold grey 7600 164 01 adapter plate for five fold hose manifold grey 7600 165 01 adapter plate suitable for example for Cattani connection bore holes 7600 166 01 Further elements for hose manifolds element for air and water spray with ANSEMS 3 esa ee ae m gane ang 7600G980 50 VistaCam element for use with D rr Dental intraoral cameras VistaCam Model 2106 7600G980 54 VistaCam iX element for use with D rr Dental intraoral cameras VistaCam Model 2108 7600G980 56 3 5 Disposable materials The following materials are required when oper ating the unit and must be ordered separately Disposable filter yellow 12 pieces 0725 041 00 3 6 Working parts and spare parts The following parts are subject to wear and tear an
6. 7600 150 00 1 Swivel arm il Mounting 6 4 Fixing to D rr Dental mounting plates Previous versions of the D rr Dental i hose manifold were fitted with the aid of a mounting plate to the wall to a swivel arm or swivel joint Where a Comfort hose manifold is re placing an older previous version then we recommend that an adapter plate is used between manifold and mounting plate Adapter plates are available in various sizes depending on the type of hose manifold see Special accessories 1 Mounting plate 2 Adapter plate e Loosen parts 1a and 1b of the mounting plate e Unscrew the older hose manifold from part la e Attach plate part 1b again to part 1a 16 e Mount the adapter plate using two M5 x 12 screws to the Comfort hose manifold e Mount the adapter plate with hose manifold Comfort to the mounting plate using M4 x 12 hex screw and M4 hex nut 6 5 Connect the hoses and lay correctly Connect the central suction hose and lay cor rectly e Connect the central suction hose to the hose manifold e Measure the length of the central suction hose between hose manifold and waste wa ter drain e g to the floor waste pipe 9000 606 18 30 1210V002 Mounting e Shorten the central suction hose to the re e Attach the hose with the clip to the central quired length suction hose e Connect the central suction hose on waste water side using the connector pieces sup plied
7. Comfort Hose Manifold Installation and Operating Instructions CE nee wl A DENTAL Contents Important information 1 Documentation 2 1 1 Warnings and symbols 2 1 2 Notes on copyright 2 Safety a fan SR ei GE nare 3 2 11 CGOMSGUUS K a i avae sonater 3 2 2 Incorrect use 3 2 3 General safety notes 3 2 4 Safe connection of appliance 3 2 5 Qualified personnel 3 2 6 Protection against electrical CUMONE sac adhe erdee a dele 3 2 7 Only use original parts 3 2 8 Transport eter ana woe dre eden 4 2 9 DISPOSAL ass steuren rumeurs 4 Product description 3 Overview zaza nen moments es 5 Sl V GS sans dates Man na dense 6 3 2 Delivery Contents 7 3 3 Accessories 8 3 4 Special accessories 8 3 5 Disposable materials 8 3 6 Working parts and spare parts 8 Technical data 9 4 1 Model identification plate 9 4 2 Note on Conformity 9 Function 10 5 1 Module set up 5 2 Triple hose manifold 5 3 Four fold hose manifold 5 4 Suction hose in position 5 5 Suction hose removed 5 6 Filter functions sic ss sean ss 5 7 RINSE AUNGHON arn arne eere a 5 8 Suction handpiece 5 9 Suction handpiece for saliva
8. VC 3 x 1 5 x 6 mm Disposable filter yellow 12 pieces Universal cannula set 2 pieces Drill template Swivel joint Rotating collar 16 mm Hose manifold installation set Installation and Operating Instructions Triple hose manifold Comfort Type GFG usure bonnets 7603G02 Larger suction handpiece 2x Large suction hose 160 cm 2x Central suction hose Rinsing hose PVC 3 x 1 5 x 6 mm Disposable filter yellow 12 pieces Universal cannula set 2 pieces Drill template Swivel joint Rotating collar 16 mm 2x Hose manifold installation set Installation and Operating Instructions 9000 606 18 30 1210V002 Four fold hose manifold Comfort Type SGFK suuananars sean 7604G01 Small suction handpiece Large suction handpiece Large suction hose 160 cm Small suction hose 160 cm Central suction hose Rinsing hose PVC 3 x 1 5 x 6 mm Disposable filter yellow 12 pieces Universal cannula set 2 pieces Drill template Swivel joint Rotating collar 16 mm Hose manifold installation set Inserts for air and water spray Installation and Operating Instructions Four fold hose manifold Comfort Type GFGK 7604G02 Small suction handpiece Large suction handpiece Large suction hose 160 cm Small suction hose 160 cm Central suction hose
9. WG can be found in our download section under www duerr de Document No 9000 461 264 2 5 Qualified personnel Instructions for use Persons who operate the appliance must on the basis of their training and knowledge en sure safe and correct handling of the appliance e Ensure personnel are trained in the correct us age of the appliance Installation and repair e Installation resetting alterations extensions and repairs must be carried out by Durr Den tal or by qualified personnel specifically ap proved and authorized by Durr Dental 2 6 Protection against electrical current e When working on and with the appliance al ways observe the local electrical safety proce dures e Never come into contact with patients and open plug in connections on the appliance at the same time e Damaged supply lines and connections must be replaced immediately 2 7 Only use original parts e Only Durr Dental parts or accessories and special accessories specifically approved by Durr Dental may be used e Only use original working parts and spare parts 1 Le Important information Durr Dental cannot accept any liability i for damage caused by the use of ac cessories and special accessories not specifically approved by Durr Dental or not using original working parts and spare parts 2 8 Transport The original packaging offers the optimum pro tection for the appliance during transport If requir
10. able locations within the hose manifold and hinder efficient function e The yellow disposable filter must be in position e Open the cover to the filter element and change the yellow disposable filter Disposable filter 12 pieces order number 0725 041 00 9000 606 18 30 1210V002 10 2 Change the suction hose The suction hose is subject to wear and tear e Check the suction hose regularly at bends change if required e Slide the suction hose from the Comfort hose manifold e Connect new suction hose 10 3 Lubricate the O rings The suction handpiece suction hoses etc are easier to handle when the O rings have been treated with a little Vaseline e Disassemble the suction handpiece regularly and lubricate the O rings gt 23 Trouble shooting 11 Tips for Operators and Technicians GJ Repairs above and beyond simple maintenance may only be carried out by a qualified techni cian or one of our service technicians Disposable filter in the hose mani Change disposable filter Reduced suction per formance fold is full Blockage in suction hose Remove and clean suction hose Blockage in suction handpiece Disassemble and clean suction handpiece Suction hose bent or twisted Change the suction hose Selective membrane does not completely open Remove filter cover Remove dirt particles e g using blunt tweez ers or jet of water Do n
11. brane and filter and into the suction system The integrated yellow filter serves to hold the larger particles back 5 7 Rinse function Connection of a rinsing unit serves to supply water to the suction system while working This serves to prevent drying out and thus prevent the build up of difficult to remove deposits in the suction system 5 8 Suction handpiece The slider fitted in the large and small suction handpieces can be used to control the rate of flow or to switch off the suction flow while work ing 5 9 Suction handpiece for saliva extractor hose with slider A rotating collar can be added to the large suc tion handpiece This enables the cannula to be turned more easily 5 10 Swivel joint A swivel joint can be attached to the large suc tion handpiece The swivel joint is rotatable in 15 steps This helps to achieve a smoother better supply of the hose Product description 12 9000 606 18 30 1210V002 Mounting G Only fully qualified or from D rr Dental 6 1 Changing hose manifold trained personnel may set up install or elements operate this appliance This section is only required in the case 6 Mounting of changing an element of the hose The hose manifold can be fixed with or without ae or whele es Genny Cements the swivel arm 1 as follows to the wall on or under a work surface e Remove the side panel e Remove the front cover pressing the sides and
12. d must be replaced regularly refer also to section on maintenance large suction hose grey AGO an aanne mate morue 7600A010 50 large suction hose grey VOO EME d zet ee bw Raw ys Be 7600S010 50 small suction hose grey U se da eme nee 7600A020 50 small suction hose black TOOG 5 2 gawd ae ae eer Hed arn 7600S020 50 Information concerning spare parts can i be found in the Spare Parts Catalogue under www duerr de etk 9000 606 18 30 1210V002 Product description 4 Technical data Unit electrical data Protective low voltage AC DC V 5 24 Surge current min mA 5 max A 4 Operating pressure mbar max hPa 200 Fusing IP23 Classification according to medical devices directive 93 42 EWG Unit Class Handpiece Class Cannula Class lla General technical data Dimensions WxHxD cm 15x18x11 Weight kg ca 1 Suction performance Universal cannula on large suction hose l min 250 350 Surgical suction can nula on small suction hose l min 50 80 Saliva cannula on small suction hose l min 30 60 Suction handpiece cannula retainer Large suction hand piece mm 216 Small suction hand piece mm 6 0 1 Suction handpiece for saliva extractor hose with slider mm 216 Hose cross sections Large suction hose mm LW 19 Small suction hose mm LW 10 central suction hose mm LW 25 Ambient conditions during operation Temperatur
13. e C 10 to 40 Rel humidity lt 70 9000 606 18 30 1210V002 Ambient conditions during storage and transport Temperature C 10 to 60 Rel humidity lt 95 4 1 Model identification plate The model identification plate to the Comfort hose manifold can be found under the filter ele ment cover Order number Model number SN Serial number 4 2 Note on Conformity This appliance has been tested according to the relevant directive of the European Union and the required conformity acceptance procedure This appliance meets all the necessary requirements Product description 5 Function Figure 5 Suction hose in position Suction handpiece Membrane Disposable filter Suction hose Suction hose central ns WN Figure 6 Suction hose removed 10 9000 606 18 30 1210V002 Product description 5 1 Module set up Due to its modular design the Comfort hose manifold can be individually set up to meet your needs depending on types of treatment or per sonal suction style and handling Between 2 and 4 elements in special cases even 5 elements can be configured for one hose manifold For other variations of Comfort hose manifold see 3 1 variants Individual elements are adjustable and can be adapted to three different ergonomic angles of application 0 15 30 5 2 Triple hose manifold The triple hose manifold has a selective func tion i e the s
14. e above and beyond that specifically described in these instructions will be deemed to be as not according to the in tended use The manufacturer cannot be held li able for any damage resulting from incorrect us age The user bears all risks WARNING Risk of explosion due to inflamma tion of combustible materials e Do not use the appliance in rooms in which combustible mixtures may be present e g in operating theatres 2 3 General safety notes e Before using the appliance observe any and all guidelines laws regulations and other re strictions which may apply to the appliance e Before each use check the function and con dition of the appliance e Do not convert or change the appliance in any way e Observe the Installation and Operating In structions precisely 9000 606 18 30 1210V002 e Keep the Installation and Operating Instruc tions in an accessible place so that the opera tor has instant access to them 2 4 Safe connection of appliance During development and construction of the unit care has been taken to incorporate all require ments of medical products as far as was possi ble As a result this appliance is suitable for in stallation within medical supply equipment e Observe the requirements under directive 93 42 EWG as well as all relevant standards when fitting into medical facilities A master copy of the system manufac i turer s declaration according to Article 12 of Directive 93 42 E
15. ed the original packaging for the unit can be ordered at Durr Dental Durr Dental cannot accept any liability i for damage caused during transport by the use of unsuitable packaging this is also valid during the warranty term e Only transport the appliance in its original packaging whenever possible e Keep the packing materials out of the reach of children 2 9 Disposal The unit may be contaminated Inform i the waste management company so that they can take all necessary safety steps e Prepare accessory parts before disposal then dispose of according to local and national regulations e If you have any questions concerning the cor rect disposal of parts please contact your dental trade supplier 9000 606 18 30 1210V002 i Product description 3 Overview Figure 1 Comfort hose manifold Type GFK 4 ND A B W Cannula e g D rr Dental universal cannula III Protect Petito prophylaxis cannula Suction handpiece for saliva extractor hose with slider Suction handpiece for larger suction hose Swivel joint Disposable filter Suction handpiece for smaller suction hose Small suction hose A TM 0 Large suction hose Clip for laying electric cable and rinsing hose Rinsing hose Electric cable Element for larger suction hose Filter element Element for smaller suction hose For further articles refer to the information leaflet order numb
16. er 9000 606 16 01 supplied and 3 4 Special accessories 9000 606 18 30 1210V002 Product description 3 1 variants G Element for larger suction hose i K Element for smaller suction hose S Element for air and water spray F Filter element G Figure 2 Double hose manifold Comfort Type FG 1 Elements FG 7602G01 G K G Figure 3 Triple hose manifold Comfort 1 Type GEK 7603G01 2 Type GFG 7603G02 Figure 4 Fourfold hose manifold Comfort 1 Type SGFK 7604G01 2 Type GFGK 7604G02 3 Type KGFG 7604G03 9000 606 18 30 1210V002 Product description 3 2 Delivery Contents Standard parts in scope of delivery of i suction hoses and suction handpieces etc are grey The following parts are included in the scope of delivery Double hose manifold Comfort Type FG 7602G01 Large suction handpiece Large suction hose 160 cm Central suction hose Rinsing hose PVC 3 x 1 5 x 6 mm Disposable filter yellow 12 pieces Universal cannula set 2 pieces Drill template Swivel joint Rotating collar 16 mm Hose manifold installation set Installation and Operating Instructions Triple hose manifold Comfort TYPE GFK ss oasis ae 7603G01 Small suction handpiece Large suction handpiece Large suction hose 160 cm Small suction hose 160 cm Central suction hose Rinsing hose P
17. ex tractor hose with slider 5 10 Swivel joint ae 11 9000 606 18 30 1210V002 Mounting 6 Mounting 13 6 1 Changing hose manifold l ments ss annee vee eend 13 6 2 Wall mounting without swivel joint 14 6 3 Wall mounting with swivel joint 15 6 4 Fixing to D rr Dental mounting Ples aie saig aea g ata 16 6 5 Connect the hoses and lay cor CV suce sien die a ae 16 6 6 Electrical connection 17 6 7 Place panel in position 18 6 8 Position and fit out suction hoses 18 8 CN Usage 7 Instructions for use 19 7 1 Tips on ease of operation 19 7 2 Tips on working with the four fold hose manifold 19 8 Disinfection and 10 cleaning 20 8 1 Disinfect and clean the hose mani fold together with the complete suction system 20 Preparation 21 9 1 Mixing instructions 21 Maintenance 23 10 1 Change disposable filter 23 10 2 Change the suction hose 23 10 3 Lubricate the O rings 23 Trouble shooting 11 Tips for Operators and Technicians 24 Important information 1 Documentation These Installation and Operating Instructions form an integral part of the unit They conform to the relevant version of the equipment and the status of technology valid at the time of
18. first op eration D rr Dental cannot guarantee smooth i operation and safe function of the unit and will not accept any liability where the instructions and notes contained in these installation and operating instruc tions are not strictly observed This translation has been carried out in all good faith The original German version is decisive D rr Dental accepts no liability for incorrect translation 1 1 Warnings and symbols Warnings The warnings in this document are there to point out possible injury to persons or damage to machinery The following warning symbols are used A General warning symbol The warnings are structured as follows SIGNAL WORD Description of type and sourceof danger Possible consequences of ignoringthe safety warning here e Measures to be taken to avoidany possible danger The signal word differentiates between differ entlevels of danger DANGER High risk of danger of serious in jury or death WARNING Possible risk of danger of serious injury or death CAUTION Risk of danger of minor injuries NOTICE Risk of serious damage Further symbols These symbols are used within the documenta tion and on the unit itself 2 Notes e g special instructions con cerning economical use of the unit Observe the accompanying documenta tion C CE labeling M Date of manufacture Dispose of product correctly and in ac TX cordance with EU directive 2002 96 mmm EG WEEE
19. iece and e g saliva cannula 9000 606 18 30 1210V002 Oy Usage 7 Instructions for use 7 1 Tips on ease of operation Adjustable inserts in the elements depend ing on function e Initial position 0 Turn the inserts to the desired position 0 15 30 Using the rotating collar suction handpiece and swivel joint amp 5 steps 1 Suction handpiece for saliva extractor hose with slider 2 Suction handpiece 3 Swivel joint 9000 606 18 30 1210V002 e A rotating collar 1 can be added to the large suction handpiece This enables the cannula to be turned more easily e The slider fitted in the large and small suction handpieces 2 can be used to control the rate of flow or to switch off the suction flow while working e A rotating collar 3 can be added to the large suction handpiece The swivel joint is rotatable in 15 steps This helps to achieve a smoother better supply of the hose 7 2 Tips on working with the four fold hose manifold Vacuum supply When using a four fold hose manifold e g GFGK KGFG and two further elements have been connected next to the filter element then both elements will be supplied with vacuum A x1 ere Ze G FGK KG FG Optimising suction performance Using as an example a hose manifold with the layout GFGK If the large suction hose G is being used then close the slider on the small suction hose K
20. lifting to the front e Pressed the section marked from both sides in order to take the element apart 9000 606 18 30 1210V002 13 Mounting e Slide both the red and the white hoses from e Use the drill template 7600 100 31 supplied the filter element to mark 3 bore positions on the wall 9 d ogoogo 1 3 4 OTO DOD 9 f e Unclamp the cable to the filter element RR e Bore 3 holes 5 mm in diameter OC OL OL bd od 4 Depending on the material pre bore and or E use dowels e Screw the first screw half way into the upper bore hole A e Install the new element in reverse order vo e Hang the Comfort hose manifold in position 6 2 Wall mounting without swivel joint e Choose a suitable location on wall for mount ing e Check that there are no cables or supply lines under the plaster 14 9000 606 18 30 1210V002 Mounting e Open the filter flap and remove the yellow filter e Insert the screwdriver horizontally through the opening and tighten the screw e Replace filter and cover 9000 606 18 30 1210V002 e Fix the mounting plate with the two screws 6 3 Wall mounting with swivel joint Instructions on installing the Comfort hose mani fold in combination with the swivel arm are con tained in the instruction leaflet order no
21. ot dam age the selective membrane No suction Suction handpiece slider is closed Open the handpiece slider Suction unit does not fuction Check the suction unit function Selective membrane does not open Remove filter cover Remove dirt particles e g using blunt tweez ers or jet of water Do not dam age the selective membrane Control hose of one element bent or twisted Check the control hose e g in element for large suction hose and filter element for signs of twisting Fluid escapes from the suction handpiece slider Dirt or accumulated deposits in suction handpiece Disinfect suction handpiece clean and then prepare see 9 Preparation 24 9000 606 18 30 1210V002 D RR DENTAL AG H pfigheimer Strasse 17 74321 Bietigheim Bissingen Germany Fon 49 7142 705 0 www duerr de info duerr de DURR DENTAL
22. r cleaning No special requirements e Disassemble e Where necessary remove larger dirt particles etc using a disinfectant disposable wipe e g FD 350 Cleaning and disinfection automatic Use cleaning and disinfection devices strictly according to manufacturer s instructions e Place the parts into the unit in such a way that the interior surfaces will be rinsed thoroughly and the water can drain off e Set up the cleaning and disinfection cycles according to the manufacturer s instructions 9000 606 18 30 1210V002 e After the cleaning and disinfection cycles have finished check the cannula carefully for signs of residual dirt and repeat the cycles if neces sary Cleaning and disinfection manual Cleaning takes place in a wet chemical process using a VAH DGHM listed instrument disinfec tion agent e Do not use an ultrasonic cleaning device or chemical autoclaven e Do not use glutaraldehyde of a phenol basis e Place the parts fully submersed in an instru ment disinfectant and cleaning agent e g D rr Dental ID 212 ID 212 forte ID 213 Ob serve manufacturer s instructions carefully e After the cleaning and disinfection cycles have finished check the cannula carefully for signs of residual dirt and repeat the cycles if neces sary e Rinse parts thoroughly with water e Drying should be carried out using hygienically clean disposable wipes or under the applica tion of compressed air Check and
23. r through the system using the system OroCup 9000 606 18 30 1210V002 Usage 8 9 Preparation 9 1 Mixing instructions Clean disinfect and steam sterilise accessories e Clean disinfect and steam sterilise cannula suction handpiece and the swivel joint if nec essary etc after every patient Observe prepa ration regulations under EN ISO 17664 Also refer to the information leaflet order number 9000 606 16 supplied Risk assessment and classification Cannula and suction handpieces are medical in struments which come into contact with mu cous membranes and skin or tissue which has been affected by illness Observe all current lo cal and national regulations concerning the cleaning disinfection sterilisation and storage of all parts In Germany a risk assessment and classification of medical devices must be carried out according to Empfehlungen der Kommis sion f r Krankenhaushygiene und Infektion spr vention Recommendations of the Com mission into Hospital Hygiene and Prevention of Infection These medical products are classified as Semicritical B requiring greater care in their preparation Transport Storage e After use place parts in a suitable closed con tainer which is filled with an instrument disin fectant solution e g ID 212 ID 212 forte ID 213 observe the manufacturer s instructions collect and transport in a securely sealed ves sel to the site of cleaning Preparation fo
24. re every usage according to EN 13060 and with sterilisation cycle Type B with subsequent drying e Observe manufacturer s instructions carefully regarding the usage of the steam sterilisator and the correct placement of items to be ster ilised e Observe all national and local guidelines and standards regarding sterilisation of medical products Storage e Store the parts protected against possible contamination Important information The instructions described above have been validated by Durr Dental as suitable and are rec ommended for the preparation of parts before and after use The surgery manager is responsi ble for ensuring that the correct and safe prepa ration of the instruments is carried out using 22 suitable apppliances materials and trained per sonnel in order to produce the desired results Validation and routine monitoring of the prepara tion procedures are necessary Any deviation from the instructions described herein by the staff preparing the equipment could lead to low er effectiveness and possible negative conse quences these lie solely with the staff responsi ble 9000 606 18 30 1210V002 Usage 10 Maintenance O Wear protective gloves 10 1 Change disposable filter Change the disposable filter once a week NOTICE Faulty function when working with out a disposable filter Working without a disposable filter runs the risk that deposits or particles will ac cumulate in unsuit
25. test of function Frequent application and cleaning has little ef fect on parts The end of the product s life cycle is determined by the amount of wear and tear or damage during usage e Always check parts before use and replace damaged parts and dispose of faulty parts e Before disposal the parts should be disinfect ed and steam sterilised Packaging e Sterilise parts either unpacked or packed in a container or in sterile product packaging Use a suitable sterile product packaging 21 Usage Steam sterilisation WARNING A The wrong sterilisation inhibits ef fectiveness and can damage the product e Only steam sterilisation is permitted e Do not exceed 134 C e Observe the process parameters e Do not use any other procedures e Place filter paper on the sterilisation tray e Always sterilise the parts together with instruments as this ensures an even temperature distribution throughout the tray contents e Avoid any metal contact of the parts either with any other instruments or with the sides of the tray e Lay parts for sterilisation avoiding any contact to the inner sides of the steri lisation chamber and on the middle tray e The product must be steam sterilised in a disassembled state only Process parameters are Temperature 134 C Nil Pressure above environment 2 16 bar 0 216 MPa Working time 5 min e Parts for sterilisation must be placed in a small steam sterilisor befo
26. tol plus together with sufficient cold wa ter to make up one liter and mix the solution e Attach the suction hose to the care system and aspirate the solution 20 e Make up 1 liter anew and distribute among max four spittoons e Allow to work for a minimum of one hour or leave overnight e After the effective working time or the next morning suck 2 liters water through using the care set OroCup Disinfect and clean surface parts e Disinfect and clean all surface areas of the Comfort hose manifold and all hoses regularly e g using FD 350 disinfection wipes 1 2 x Weekly Clean the suction system 1 2 x week on heavier patient loads also during the midday break using special cleaning agent For water with higher calcium levels we i recommend using a special cleaning agent for suction systems such as MD 555 cleaner This has a stronger clean ing action against deposits scaling and sludge accumulation e As pretreatment suck up 2 liters of water through the system using the system OroCup e Preparing the solution For a single treatment unit 50 ml 2 5 cap fulls MD 555 cleaner together with sufficient cold water to make up one liter and mix the solution e Attach the suction hose to the care system and aspirate the solution e Make up 1 liter anew and distribute among max four spittoons e Allow to take effect for 0 5 to 2 hours midday break e After the effective working time suck up 2 lit ers of wate
27. uction hose actually being used at any moment is supplied with vacuum 5 3 Four fold hose manifold The selective function for the four fold hose manifold is restricted to the single element next to the filter element As soon as two further elements are used next to the filter element then both are supplied with vacuum X i AS sm G F GK KGF De 5 4 Suction hose in position When the suction hose is placed into the hose manifold the switch is pressed and the valve is thus closed Atmospheric pressure is present in the upper section of the selective membrane Due to the arrangement of the selective membrane the path between suction hose and suction system is interrupted 5 5 Suction hose removed By removing the suction hose a valve and two microswitches are activated One microswitch activates the suction unit the other can regulate the station selection valve or the separation for example The valve opens Due to the vacuum created by the suction unit the membrane rises and opens the path between suction hose and suction system 9000 606 18 30 1210V002 Both the large and small suction handpieces are fitted with a slider to control the rate of flow or to switch off the suction flow while working 5 6 Filter function During suction of spray mist saliva and other particles from the patient mouth these are then passed through the suction hose and via the open mem

Download Pdf Manuals

image

Related Search

Related Contents

Knobby/Slidemate MIDI Controller User's Manual  User`s Manual  Model GS-800 ™ Calibrated Imaging Densitometer - Bio-Rad  EPC PM Nautic Installation Manual  Combivert F0_Spain.indb  VSP 112W User Manual    Manual de Usuario Manual do Usuário  BTS-200 Kit mains libres Bluetooth® pour auto Manuel d`utilisation  Macintosh PowerBook 110  