1. 2 seconds enters to time setup menu Using A V 4 P and REF SEL keys to setup time After the setup press Power key less than 2 sec to save the setting and exit 5 Pressing Threshold key for more than 2 seconds enters to threshold setup menu Select one group of threshold from the preset list and press Power key less than 2 sec to exit 6 Press Mode key to select a test mode and then the instrument will execute the test automatically and display the test results on the LCD screen 7 Power Off After completing the test pressing Power key for more than 2 seconds to shut down the instrument 10 AZJPROMAX PROLITE 57 5 5 Detail Operation 5 5 1 Powering On the Instrument Press the Power kev to turn on the instrument It will automaticallv go to test menu In test menu press Power kev and release quickiv less than 2 seconds to activate or deactivate Auto shut down function The auto shut down function means the instrument will shut down automaticallv if the instrument has not been operated for a certain period of time The time period can be set The defaultis 10 min 1 AX PROMAX PROLITE 57 5 5 2 Test mode switch In the test menu press Mode to switch between normal test mode and P F test mode 1 Normal test mode Normal test mode means do not setup threshold value but display optical power directly In this mode the LED indicators will not light The results are displayed in two units dB and dBm usin
2. as follows 0 Main unit 0 4 Ni MH Batteries Carrying Case CD software User s Guide 2 SC amp ST adaptors 0 3 Ferrules 0 USB USB mini cable Case strap AC Adapter Checking for damage in transit After unpacking the instrument check to see whether it was damaged in transit This is particularly likely if the outer casing is clearly damaged If there is damage do not attempt to operate the instrument or to repair it without authorization Doing so can cause further damage and you may lose your warranty qualification AX PROMAX PROLITE 57 5 Operation 5 1 Lavout ONU The front panel is divided in two parts Part I LCD Display Part Il Keypad The tester shows test result on LCD screen and in the meanwhile indicates different status in part 2 by LED Tester connector types SC APC ST APC L i i i p i 2008 08 22 17 00 01 e amp 1310nm dBm ONU 1 5 2 Pass 1490nm dBm OLT 4 5 warning 1550 eee 15 0 mode Threshold t demdB REF SEL Time mm LLLLLLLLLLU L Video OLT Parti Part 2 AZRJPROMAX PROLITE 57 5 2 Kev s Functions Power Switch Press the kev to Power On the unit While the unit is in the state of power on if pressing down the key and release quickly less than 2 seconds the unit will switch to auto power off if pressing down the key for longer than 2 seconds the unit will shut down If the unit is in threshold setup tim
3. dBm dB can switch unit between dBm and dB Here the unit dBm is the actual power and unit dB is a power value relative to reference value Refer tonext section about Reference value setup When the instrument is in the P F test mode pressing dBm dB kev will automaticallv exit P F test mode and switch to normal test mode Its unit will be in dB ARSPROMAX PROLITE 57 5 5 6 Reference Value Setup In the test menu press REF SEL key for more than 2 seconds then the LCD will display REF in red see Fig 5 This means the instrument choose the current light power as reference value The test results afterward are the values after comparing to this reference value Now the unit will be in dB and LED below LCD displav will not light 2008 08 22 17 00 01 e lt gt 1310nm ONU wm REF 1550nm VIDEO Auto off Fig 5 REF Value Setup Menu In the test menu press and release REF SEL key quickly less than 2 seconds then current reference value will appear on LCD display See Fig 6 2008 08 22 17 00 01 G amp G ee 12 1490 or AS 1550 50 E Auto off Fig 6 View REF Value Menu 16 ZXPROMAX PROLITE 57 5 5 7 Backlit Setup Pressing Threshold and REF SEL keys at same time enters to backlit setup menu See Fig 7 2008 08 22 17 00 01 lt gt Zz Fig 7 Backlit Setup Menu In this menu press A Mode key to brighten the backlit and W dBm dB key to weaken the backlit After compl
4. easv visibilitv and LED indicators Simply connect and displav the results of all three wavelengths 1310 1490 1550 nm of PON signals with two optical ports Detect and measure the upstream burst at 1310 nm Support APON BPON EPON and GPON networks Pass Fail and Warning indicators for easy view of signal condition User definable threshold value up to 10 sets Auto power shut off Low battery warningUSB interface Real time clockUnit runs either by Ni MH battery for more than 20 hours continuously work or AC DC adapter AZJPROMAX PROLITE 57 1 3 Specification Continuous Datastream 40 dBm 10 dBm 40 dBm 20 dBm Burst measurement range 30 dBm 10 dBm 1310 nm bursted signal Spectral Passband 1310 nm 1490 nm 1550 nm 1260 nm 1360 nm 1480 nm 1550 nm 1539 nm 1565 nm Insertion Loss 1 5 dB Accuracv 40 5 dB Linearitv 10 2 dB Displav 2 8inch TFT LCD Refresh Rate of Display Threshold 10 sets configured via PC based software Auto Power off Yes Number of Ports 2 ports One for 1310 nm ONU and one for 1490 nm 1550 nm OLT 0 95 non condensing 190 mm 105 mm 55 mm L W H with rubber protector 3 AZJPROMAX PROLITE 57 3 Safetv Information SAFETV RULES e The safety could not be assured if the instructions for use are not closely followed e The external DC charger is a Class Il equipment for safety reasons plug it to a supply line with the corresponding ground terminal e Use the mai
5. OPTICAL INSTRUMENTS SERIES User s Guide to the PROLITE 57 PON Power Meter PA PROMAX v1 0 0 MI2029 01 12 2014 FID y Ce x 5 5 5 5 a 5 ki gt I D 2008 08 22 17 00 01 lt MAN 1 2 1490nm dBm OLT 4 5 warning 1550 DIN SSO fr PROLITE 57 1 Introduction 1 1 Summarv PROLITE 57 is a portable high quality PON optical power meter It is specifically designed to meet the rapid growth of FTIx market with PON Passive Optical Network technologies It is capable to measure all three signals 1310nm 1490nm and 1550nm that carry voice data and video so called triple play applications along a single fiber PROLITE 57 can measure not only 1490nm and 1550nm optical signal but also accurately detect and measure the upstream burst at 1310nm sent from an ONU while the ONU is in the idle mode The simple Operation and accurate measurement make PROLITE S7 becomes an ideal tool for PON suitable for APON BPON EPON and GPON application installation acceptance test to ensure that they meet required standards and service activation and troubleshooting AZJPROMAX PROLITE 57 1 2 Main Function and Specifications Cost efficient palm size designed for field and lab testing Support P F measurement and normal measurement Easv to use interface with large color TFT displav for
6. and 1550 nm Video respectivelv The RED color indicates Fail ORANGE color is Warning and GREEN color means Pass Thresholds The definitions for the three states Fail Warning and Pass are described as below If assuming the instrument s measuring upper limit as Limiti and lower limit as Limit2 the Pass threshold value in instrument s internal setup are Threshold1 Threshold2 as Warning threshold and Threshold3 as Fail threshold also Limit2 lt Threshold3 lt Threshold2 lt Threshold1 lt Limit1 P value represents measured optical power then 1 1f P lt Limit2 means the power is Low the LED will indicate in RED 2 1f Limit2 lt P lt Threshold3 means Fail the LED will indicate in RED 3 lf Threshold3 lt P lt Threshold2 means Warning the LED will indicate in ORANGE 4 1f Threshold2 lt P lt Threshold1 means Pass the LED will indicate in GREEN 5 1f Threshold1 lt P lt Limiti means Fail the LED will indicate in RED 6 1f P gt Limiti means the power is High the LED will indicate in RED 9 AZJPROMAX PROLITE 57 5 4 Quick Operation 1 Connect the instrument to the optical link under test 2 Press Power On kev to turn on the instrument 3 Pressing down Threshold key and REF SEL key at same time enters to Backlit setup menu Using A and Y keys to adjust backlit to a suitable brightness then press Power key again to save the backlit setup and exit Backlit setup menu 4 Pressing Time key for more than
7. ans the power value of corresponding wavelength 20 2008 08 22 17 00 01 imm 25 1310 1490 1550 13 high high high X 14 high high high i high high high 16 high high high iy high high high IB high high high i high high high 20 high high high 4 gt 44 bb Esc X RST Fig 11 AZJPROMAX PROLITE 57 6 Remarks 1 When batterv power is not enough the batterv indicator will flash Please immediatelv use the attached AC DC adapter or charge the instrument battery 2 While charging the instrument does not allow the user to power off If pressing Power Off key the charger head will flash After the battery gauge shows full means the battery is fully charged remove the charger 3 Before charging the instrument please make sure the rechargeable battery pack is installed If do not use the instrument for long time please remove the battery pack to avoid battery descompotion 5 Due to existence of strong interference in some working environment sometime short lines or disorder may appear on LCD screen this is normal and not going to affect the instrument The display will back to normal if reboot the unit or switch menu to refresh the display 2 ZXPROMAX PROLITE 57 7 Advice 1 Please use the dust proof cap to secure the connector to be scratched or contaminated everytime when the product is not in operation 2 Please always stay the optical connectors away from oil dirt and other contam
8. d key quickly 15 0 less than 2 seconds to switch the wavelength among 1310 nm 1490 nm and Nh Telecom 1550 nm Press A Mode key to view previous record W dBm dB key to Fig 3 Threshold Setup Menu view next record REF SEL key to validate the current threshold value After above operation all P F mode test results will base on this threshold value Note The threshold value can only be preset by PC software See PC software section for detail After finishing the setup press Power key less than 2 sec to exit the setup menu 13 MRPROMAX PROLITE 57 5 5 4 Time Setup Pressing Time kev for more than 2 seconds enters to time setup menu see Fig 4 2008 08 22 17 00 01 lt gt Time Setup 08 10 25 15 02 03 Yes Fig 4 Time Setup Menu In the time setup menu the Threshold key becomes lt left gt arrow key and REF SEL key becomes lt right gt arrow key using them to move cursor When cursor moves to a number the user can use A Mode key to increase value and W dBm dB to decrease value When cursor moves to Yes and press REF SEL key for more than 2 seconds the Yes will flash means the instrument accepts the time change During the time setup the user can press Power key less than 2 sec to exit time menu and back to test menu then the system time setup remains unchanged 14 AZJPROMAX PROLITE 57 5 5 5 Unit Switch When the instrument is in normal test mode pressing
9. e setup and backlit setup menu the key becomes ESC key to exit the menu Mode Key test mode It is used to switch the test mode P F test mode and normal test mode When the unit is in time setup threshold setup and backlit menu the key is used to increase value Threshold It is used to set threshold Pressing it down for more than 2 seconds enters threshold setup menu In threshold setup menu press and release the key quickly less than 2 seconds to switch wavelength In time setup menu this key functions as lt left gt arrow key dBm dB Time unit switching key Press and release the key quickly less than 2 seconds to switch unit between dB and dBm pressing the key down for more than 2 seconds enters to time setup menu In time e setup menu threshold setup and backlit setup menu the kev is used to decrease value key quickly less than 2 seconds then the key will function as lt right gt arrow key REF SEL It is used for reference value setup and selection If pressing it down for more than 2 seconds the instrument will take current light intensity as reference to do measurement If pressing and release the AZJPROMAX PROLITE 57 5 3 Definitions LEDs Not oniv the instrument will displav measured optical power value on LCD screen but also under P F test mode its three LED indicators will function with following meanings The three LED indicators represent upstream 1310 nm ONU downstream 1490 nm OLT
10. eting the setup press Power key less than 2 sec to save the setting exit and back to the test menu 17 AX PROMAX 5 5 8 Description of Memory Record Function Description of Interface At the main interface it shows the current recording number on the left bottom of the page Displaying num xxxx xxxx means the current recording number the maximum number up to 1000 pieces As you may refer to the picture 8 it means there are 24 pieces of test recording inside Press the mode button for longer than 3 seconds to save the current testing value as you may refer to the picture 9 the recording number automatically adds 1 when the interfaces shows Save 18 PROLITE 57 2008 08 22 17 00 01 LQ hz 1310nm dBm oa Low 1490nm dBm a Low 1550nm L Abia VIDEO OW num 0024 Auto off Fig 8 2008 08 22 17 00 01 LQ kz Fig 9 AXPROMAX PROLITE 57 At the record view interface refer to picture 10 the characters on top of horizon line are total number of recording and wavelength from left to right The characters under horizon line are the number of recording and the optical power value in accordance to the corresponding wavelengths On the bottom of the page you may see the main menu 2008 08 22 17 00 01 c 1310 1490 1550 low low low low low low low low low WN RR ID 4 gt 4 bb Esc X RST Description of button Fig 10 Simultaneously press Mode and Th
11. g dB dBm key to switch See Fig 1 Unit dBm is to display the actual power Unit dB is to display a power value relative to reference value In this mode reference value needs to be preset correctly 2 P F test mode P F test mode means the measured light power comparing to preset threshold value to determine if the measured light power meets user s requirement or not LCD will display the optical power and current state The LED indicators below the LCD display will also change color to match the current state of measured light This test mode is very useful in some special cases required see Fig 2 12 2008 08 22 17 00 01 lt gt 1310nm dB aoe ie 2 1490nm dB OLT 4 5 1550 Emoe Auto off Fig 1 Normal Test Mode Menu dB 2008 08 22 17 00 01 ek oe 12 1490 i l 5 Mina 1550 e50 E Auto off Fig 2 P F Test Mode Menu AZJPROMAX PROLITE 57 5 5 3 Threshold Setup The user can setup the value The steps are as following In the test menu pressing Threshold kev for more than 2 seconds enters to threshold setup menu see Fig 3 2008 08 22 17 00 01 lt In this menu left side displays wavelength and right side displays threshold a 1 2 Pass value Top line indicates system information date amp time and bottom line a indicates the information of threshold including threshold symbol threshold BEING 4 3 vein number and name In this menu press and release Threshol
12. ill be a warning of indicator keeps blinking then please replace the batteries or plug in AC adapter to charge batteries 2 Please make sure that you have turned the instrument on before charge the batteries unplug the AC adapter when the batteries are fully charged 3 Please make sure the batteries are well placed before charge them 4 To eliminate the possibility of acid leakage please take out the batteries if the unit will not be used for a long time AC operation If the instrument is mainly used at one location e g ina laboratory or test department the AC adapter can be used to power it instead of batteries There is a DC input jack on the left side of the PL 57 instrument casing into which the output cable of the AC adapter is plugged And when the AC adapter is plugged in the AC Indicator on the LCD will be displayed Note 1 Power is supplied by the AC adapter even if battery is fitted And the battery indicator is not displayed on the screen when AC adapter is plugged 2 Make sure that the operating voltage of the AC Adapter Charger is the same as the local AC line voltage AZJPROMAX PROLITE 57 4 Preparing for Operation Unpacking the instrument Packing material We suggest that vou keep the original packing material Using the original packing material is vour guarantee of protecting the instrument during transit Checking the package contents The standard accessories of PROLITE 57 are
13. ination to ensure the proper operation 3 Always be careful when you are intend to plug in and pull out the connectors because optical interface is extremely sensitive 22 PROMAX ELECTRONICA S L Francesc Moragas 71 75 08907 L HOSPITALET DE LLOBREGAT Barcelona SPAIN Tel 93 184 77 00 Tel Intl 34 93 184 77 02 Fax 93 338 11 26 Fax Intl 34 93 338 11 26 http www promaxelectronics com e mail promax promaxelectronics com
14. ns adapter in Overvoltage Category Il and Pollution Degree 1 installations To use INDOOR e When using some of the following accessories use only the specified ones to ensure safety Power adapter e Observe all specified ratings both of supply and measurement e Use this instrument under the specified environmental conditions e The user is not allowed to carry out the following maintenance operations Any change on the equipment must be carried out exclusively by technical staff e Follow the cleaning instructions described in the Maintenance paragraph AX PROMAX PROLITE 57 Symbols related with safety Discharged batteries MT DIRECT CURRENT ON Supply FN ALTERNATING CURRENT OFF Supply DOUBLE INSULATION Class II protection O bi AN CAUTION A DIRECT AND ALTERNATING GROUND TERMINAL Risk of electric shock CAUTION REFER TO MANUAL NU wl L PROTECTIVE CONDUCTOR FRAME TERMINAL FUSE Ww EQUIPOTENTIALITY oD hd EQUIPMENT OR COMPONENT A TO BE RECVCLED e Specific Precautions Never look directly into optical outputs or a fiber while the equipment is on Invisible laser beam may damage your eyes Descriptive Examples of Over Voltage Categories Cati Low voltage installations isolated from themains Catil Portable domestic installations Cat lll Fixed domestic installations CatIV Industrial installations 1 When the battery power is almost out there w
15. reshold to enter the record view interface press the shortly to exit it refer to picture 10 for this interface At the record view interface you may see the main menu on the bottom of the page they are from left to right lt gt lt lt D gt ESC X RST There is an underline when you selected the menu the ESC has been chosen in picture 10 press Threshold shortly to move the underline from left to right after the underline moved to your ideal menu press REF SEL shortly to execute it AX PROMAX PROLITE 57 Description of everv individual menu 4 Page up to the last 10 recording gt Page downto the next 10 recording 44 Page up to the last 100 recording gt Page down to the next 100 recording ESC Exit the record view interface same as press X Select one or more than one recording to delete RST Reset the recording memory this operation is not reversible and it ll take 5 seconds to complete with power supply can not be disconnected otherwise it may damage the chip of tester At the record view interface press mode button to move X upward one step press dBm dB button to move X downward one step In picture 10 the interfaces explains that there are totally 3 testing result inside low means the saving power value is lower than the value from threshold setting In picture 11 high means the saving power value is higher than the value from threshold setting The digital me