Home

AIDA64 Business

image

Contents

1. This process can be automated with command line options Using the switches RMTREPORT or RMTHOST we can create full reports of remote computers while we can select report profiles by using SUM HW SW BENCH AUDIT or CUSTOM after RMTREPORT or RMTHOST REPORT REVIEW After selecting the report profile and the report format the report creation process begins After all information has been collected the generated report is displayed in the Report review window From this window it can be printed saved to a report file or sent in an e mail using the SMTP MAPI or Outlook protocol AIDA64 can automatically compress reports before saving or e mailing them This function can be enabled in Preferences Report SQL database reports cannot be previewed in the report review window File ll Save To File Send In E mail Submit To FinalWire Print Preview gen Print EY Close Summary Computer Summary Ki Computer Motherboard Computer Name Computer Type ACPI x64 based PC Operating System DMI Chassis CHIEFTEC CD 01 B B350 3 Power Supply CODEGEN 350W Server Overclock Ly Operating System Microsoft Windows 8 1 Professional im OS Service Pack 2 Internet Explorer 11 0 9600 17207 Multimedia Portable Computer Directx DirectX 11 2 Computer Name OFFICE103 User Name oliver mesztrics Network s Logon Domain ABSEIRA Date Time 2014 07 11 12 52 Display Power Management Storage Sensor
2. Menu Favorites y Field Value EZ aipasa 32 Account Security Properties b JE Computer E Computer Role Primary gt Motherboard uE Domain Name OFFICE103 p 3 Operating System E Primary Domain Controller Not Specified a E Server 82 Forced Logoff Time Disabled E Share Min Max Password Age 1 42 days w Opened Fil a 22 Minimum Password Length 7 chars E Password History Length 24 items 3 Lockout Threshold Disabled al Lockout Duration 30 min E Lockout Observation Window 30 min ae l Local Groups BA Global Groups Logon This page lists all the users who are currently logged on Users This page lists the domain users If we do not use a domain local users are listed here By double clicking the information window at the top we can modify user and group settings Local Groups This page lists the local groups By double clicking the information window at the top we can modify the group settings Global Groups This page lists the global groups By double clicking the information window at the top we can modify the group settings 97 AIDA64 Business DISPLAY Windows Video Page menu This page lists the available graphics adapters and information about the installed drivers Double clicking a graphics adapter will load the Windows Display Properties Screen Resolution window where we can modify our display settings PCI AGP Video This page lists the available PCI AGP and PCI Exp
3. Date 2014 03 15 10 03 00 2014 03 17 9 52 00 2014 03 17 16 10 00 Computer Name E OFFICE 101 o E OFFICE 101 o E Full HTML Report OFFICE 103 outdated X Delete Selected Reports gt Delete Outdated Reports to finished by clicking Set RComplete field to yes But bear in mind that Change Manager uses outdated reports to detect changes Switch RComplete Field to Yes OFFICE 101 outaated E OFFICE 101 outdated E OFFICE 101 E OFFICE 102 outdated E OFFICE 102 outdated Jm OFFICE 102 1E OFFICE 103 outdated E OFFICE 103 outdated E OFFICE 103 outdated SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM we 2014 03 18 8 11 00 ADAG Vs 2014 03 19 8 31 00 AIDA64 v4 AIDA64 va AIDA64 va AIDA64 v4 AIDA64 va AIDA64 v4 AIDA64 v AIDA64 v4 2014 03 20 8 10 00 2014 03 24 8 04 00 2014 03 17 9 27 00 2014 03 17 9 46 00 2014 03 18 22 38 00 2014 03 17 16 13 00 2014 03 18 9 08 00 2014 03 19 9 00 00 hel OFFICE 103 outdated SWSTEM SYSTEM SYSTEM SYSTEM E 1 users E OFFICE 103 outdated 1 OFFICE 103 E OFFICE 104 outdated Ni 19 computers 2014 03 20 8 51 00 AIDA64 v4 2014 03 21 8 50 00 AIDA64 v4 2014 03 24 8 24 00 Yes AIDA64 v4 2014 03 17 13 52 00 Yes Ni OFFICE 103 outdated 118 days o CHANGE MANAGER Change Manager can greatly facilitate the job of system admini
4. Registry User Last run date will be stored in a user specific location in the Windows Registry This option is useful for network audits when reports should be created per user and not per computer For example when Once a day schedule limit is specified and a computer is used by 3 different users 3 reports will be created of the computer per day one report for each user CATAG SHOSTNAME sys Last run date will be stored in a hidden file named CATAG lt computername gt SYS This option is identical to the Registry Machine option but it does not CATAG SUSERNAME sys Last run date will be stored in a hidden file named CATAG lt username gt SYS This option is identical to the Registry User option but it does not modify the 0 users log in and out 0 0 modify the Registry 0 Registry 0 Custom file Last run date will be stored in the specified file Variables GSHOSTNAME and or SUSERNAME have to be used in the specified file name For example if we store this information in the computer name and we configured AIDA64 to make a report once a day only one report will be created on the given computer when we use command line options no matter how many times we run the command Still we can create further reports if needed using the Report Wizard or from a central computer using the Remote Report Wizard Search Schedule 3H Language y General ll La
5. Your e mail address thank you com On Demand Report Submit Sensor Debug Embedded Ctrl C ACPI DSDT REPORT CONVERTER Report Converter can be used to convert CSV or XML report files to CSV XML or HTML format We can select the files to be converted one by one or we can convert a TOE _ E EL DA Linux 2014 04 28 debian_20140429123509 csv complete folder containing report files F DA Linux 2014 04 28 linux fmap_20140429155648 csv After pressing the OK button AIDA64 will E D Linux 2014 04 28 Linux Mint_20140429140628 csv a Ds Linuwd 2014 04 28 Linux Mint 16_20140429110415 csv save the converted files into the selected 1 D Linwa2014 04 28 ubuntudes 2014042900344 csv destination folder Destination Destination folder D Reports DATE Type of converted reports HTML 67 AIDA64 Business Report REMOTE REPORT WIZARD We can also create reports of remote computers using Remote Report Wizard in which we can also select the desired report profile Then we can define the format in which we want to save the report e Plain text Remote computers l H T M L Please choose the computers you want to have report of M HT M L Address Computer Name o XML Je e Mi 192 168 1 1 AM DON M 192 168 1 2 e CSV Ml 192 168 1 3 kh E e MIF Y pil 192 168 1 4 Ml 192 168 1 5 e INI Mi 192 168 1 6 yl 192 168 1 7 Mi 192 168 1 8 y 192 168 1 9 e ADO to be inserted in a database
6. Enable HTML report menu o D Remarks 018 Include debug information in TXT HTML MHTML reports F E mail LJ ay Include debug information in CSV reports Database _ pi Show computer name in caption of the first report page y Ml Summary O A Compress reports before saving to file ay Custom Variables Y Comnress renort lt hefore sendinn in e mail Y Content Filtering a Custom Components Personal ue Asset Profile 2 Full name gt ME Remote Features ff Custom Programs ca D ya File Scanner 4 A Network Alerting A Alert Methods m Alert Triggers b E Hardware Monitoring Cancel Apply Report title This option specifies the first line of the reports 24 AIDA64 Business Preferences XML style file AIDA64 Business and Network Audit support the application of XSLT transformation on XML report files If we specify a stylesheet here the software will insert a reference to this into the XML report for example lt xml stylesheet type text xsl href C XSL AIDA64_template xsl gt If we save the XML report to the same folder where our XSL file is located it is enough to specify the file name only without the full path In such cases the report preview window of AIDA64 will not show the XSL transformed XML unless we copy the stylesheet to the TEMP folder of the active user If we use several PCs we can use the following script to copy the stylesheet to the TEMP direc
7. File Edit View Columns ote F gt e Monitor s Refresh ES Preference i i Remote System Information Connected 4 Pending 0 ee REMOTE LOMntro Address os a EE iskTotal Disk Free Network Anti Virus jE 192 168 1 116 8 1 DO J Browse Files 0372 MB 749076 MB 16 2 KB 2014 06 13 Ea eR E Processes 3372 MB i 1 192 168 1 119 8 01 a Screen Shot 5505MB 56936 MB 0 8KB s 2014 06 13 Ml 192 168 1120 8 M Operations Si Run Program 0 KB s 2014 06 13 Eg End Process x Disconnect Start Service 1 Stop Service E Close AIDAG4 E Restart AIDAG4 0 Turn Off BB Restart B Log Off 70 AIDA64 Business Remote features 6 1 1 The following settings are available for the Remote Monitor feature General On the General tab we can customize the layout and specify 5 processes and 5 services we would like to monitor Update Here we can specify how often we would like to update the information in the columns in seconds Columns The columns selected here will be displayed in the Monitor Remote Computers module By default all columns are selected Computer Groups Here we can create computer groups There are three ways to add computers to a group e computer name eg ADMINPC e IP address eg 192 168 0 8 e IP address range eg 192 168 0 1 192 168 0 21 lt is possible to add multiple addresses if we separate them by comma but we can create mo
8. OFFICE102 OFFICE104 13 SRVR2012 11 OFFICE119 OFFICE120 SRVR OFFIC SRVRS OFFICE106 OFFICE1O7 OFFICE108 OFFICE101 OFFICE102 OFFICE103 SAWR3 AIDA64 Business File menu DATABASE MANAGER Database Manager can be used to maintain SQL databases and will load reports from our existing database though it is possible to add report files to our database later We can find the option to insert report files to database in the Operations menu Here we can choose to add individual report files or entire folders Export Selected Reports Computer Name Full HTML Report E OFFICE 101 044 AIDAB4 v4 2014 03 15 10 03 00 Ml OFFICE 101 oy 4 Delete Selected Reports AIDA64 v4 2014 03 17 9 52 00 E OFFICE 101 ou AIDA64 v4 2014 03 17 16 10 00 JE OFFICE 101 ot AIDA64 v4 2014 03 18 8 11 00 E OFFICE 101 outeratet SYS AIDA64 v4 2014 03 19 8 31 00 E OFFICE 101 outdated SYSTEM AIDAG4 v4 2014 03 20 8 10 00 pl OFFICE 101 AIDA64 v4 2014 03 24 8 04 00 E OFFICE 102 outdated AIDA64 v4 2014 03 17 9 27 00 E OFFICE 102 outdated AIDA64 v4 2014 03 17 9 46 00 pl OFFICE 102 AIDA64 v4 2014 03 18 22 38 00 E OFFICE 103 outdated AIDA64 v4 2014 03 17 16 13 00 E OFFICE 103 outdated AIDA64 v4 2014 03 18 9 08 00 E OFFICE 103 outdated AIDA64 v4 2014 03 19 9 00 00 E OFFICE 103 outdated AIDA64 v4 2014 03 20 8 51 00 E OFFICE 103 outdated AIDA64 v4 2014 03 21 8 5
9. DirectX Devices Motherboard CPU Type QuadCore Intel Core i5 3450 3500 MHz MSI B75MA P45 MS 7798 1 PCI 1 PC Security R3 DIMM Audio Video Gigabit LAN Software Motherboard Name E Motherboard Chipset Intel Panther Point B75 Intel Ivy Bridge Met m System Memory 8064 MB DDR3 1333 DDR3 SDRAM DIMM1 Kingmax FLGF65F 4 GB DDR3 1333 DDR3 SDRAM 9 9 9 2 592 MHz 7 7 7 19 D8KQB 518 MHz 6 6 6 16 444 MHz EN mu DIMM3 Kingmax FLGF65F 4 GB DDR3 1333 DDR3 SDRAM 9 9 9 2 MUON Database 592 MHz 7 7 7 19 gt 2093 KB 68 AIDA64 Business Remote features 6 REMOTE FEATURES The activity and status of a whole network of computers can be monitored remotely with AIDA64 Remote Monitor Applications and services can be launched remotely remote computers can be shut down or restarted With AIDA64 Remote Control it is also possible to take full control of the remote computer to perform administrative tasks and transfer files REMOTE MONITOR Using Remote Monitor we can monitor the activity and the health of networked computers and intervene if required To use this feature we need to open the Monitor Remote File Edit View Columns Remote Computers dialog by selecting Remote Remote Monitor on Refresh HE Preferences PL Disconnect Al the menu bar Here we will be able to connect to those PCs Connected 0 Pending 0 Busy 0 Error 0 Disconnected 0 on which remote connections are
10. Menu Favorites Field Value EZ Remote Session OFFICE101 EY CPUID Properties b Ml Computer gt Server gt AL Display gt Multimedia gt 83 Storage gt AP Network gt E DirectX gt El Devices gt El Software gt Security gt E Config gt Database gt JS Benchmark A notification bubble above the notification area will appear on both the local and the client computer to inform the user that there was a successful or unsuccessful attempt to establish a remote connection During the remote session the AIDA64 icon in the notification area will turn red It is possible to hide the bubble notification and the icon DO CPUID Manufacturer A CPUID CPU Name A CPUID Revision BA Brand ID A Platform 1D n Microcode Update Revision R HTT CMP Units f Tjmax Temperature As CPU Thermal Design Power As CPU IA Cores Thermal Design Current As CPU GT Cores Thermal Design Current CPU Max Power Limit A CPU Power Limit 1 Long Duration cpu Power Limit 2 Short Duration W Max Turbo Boost Multipliers a Instruction Set 64 bit x86 Extension AMD64 Intel64 C AMD 3DNow C AMD 3DNow Professional C AMD 3DNowPrefetch C AMD Enhanced 3DNow Remote Session OFFICE101 AE Remote OFFICE101 LE Information A Version a User Name JE Comment using the SILENT command line option 64 12 Genuinelntel Intel R Core TM 15 3450 CPU 3 10GHz 00030649h 00h
11. Test button can be used to send a test alert message Search E Report Report File 3 Database Ni Summary cf Custom Variables Y Content Filtering y Custom Components mje Asset Profile a Remote Features E Custom Programs gt J File Scanner D Network Alerting D Q Hardware Monitoring E mail i E mail transfer protocol SMTP m Zm __ Microsoft Outlook To address to abse Microsoft Outlook Cc address Bcc address blind carbon copy abseira com _ Embed TXT reports to e mail body SMTP is the recommended protocol for network audit SMTP can be configured in the following submenu 3 6 1 SMTP Here we need to add a display name of our choice our e mail address and the address of the SMTP server we use lf we use an SMTP port other than the default port 25 we have to specify it here lf we use SMTP authentication we can add the user name and password here Search a Report __ Report File E D Report Look 1D Schedule a E mail if Database li Summary Ef Custom Variables Y Content Filtering a 24 Custom Components ge Asset Profile 4 ME Remote Features S Remote Control E al Custom Programs D P File Scanner gt A Network Alerting D Q Hardware Monitoring SMTP pa Display name Alert E mail address alert absei
12. fast the CPU can write data into the system memory 3 4 Single Precision FLOPS Measures the MAD Multiply Addition performance of the GPU otherwise known as FLOPS Floating Point Operations Per Second with single precision 32 bit float floating point data 17 AIDA64 Business Tools Double Precision FLOPS Measures the MAD Multiply Addition performance of the GPU otherwise known as FLOPS Floating Point Operations Per Second with double precision 64 bit double floating point data Not all GPUs support double precision floating point operations For example current Intel desktop and mobile graphics devices only support single precision floating point operations 24 bit Integer IOPS Measures the MAD Multiply Addition performance of the GPU otherwise known as IOPS Integer Operations Per Second with 24 bit integer int24 data This special data type is defined in OpenCL given that many GPUs are capable of executing int24 operations in their floating point units effectively increasing integer performance by a factor of 3 to 5 when compared to 32 bit integer operations 32 bit Integer IOPS Measures the MAD Multiply Addition performance of the GPU otherwise known as IOPS Integer Operations Per Second with 32 bit integer int data 64 bit Integer IOPS Measures the MAD Multiply Addition performance of the GPU otherwise known as IOPS Integer Operations Per Second with 64 bit integer long data
13. ES Config E Database Benchmark Description Computer description system summary Motherboard processors memory chipset BIOS information Operating system services processes drivers information Server information Display adapters monitors desktop information Multimedia devices audio and video codecs information Hard disks CD amp DVD drives SMART information Network subsystem information DirectX devices information PCI AGP PnP USB PCMCIA devices list printers information Software subsystem information System security information System configuration information Database BDE ODBC information Measure system performance E AIDA64 E Local Copyright c 1995 2014 FinalWire Ltd a 11 48 Br d n 07 04 2014 y A ACCEPT INCOMING REMOTE CONNECTIONS After launching AIDA64 on the computer we want to monitor we can select Accept Incoming Remote Connections under Remote on the main menu bar Two files aida_rcs dll and aida64 exe will File View Report Remote Favorites Tools Help est Menu D Z AIDA64 gt 1 Computer gt Motherboard b a Server gt A Display gt lg Multimedia gt Storage gt EP Network gt GP DirectX gt 8 Devices gt El Software gt ME Security gt ES Config gt EF Database gt 13 Benchmark FZ AIDAG4 IGNORE INCOMING REMOTE CONNECTIONS This menu item can be used to prevent remote computers c
14. Y Mi Enable DMI page Y Enable OpenAL page Report File y e Enable OpenGL page E 7 0 Report Look Y Enable DirectX menu ol AD Schedule v E Enable Config menu 0 V EE Enable Database menu Y 73 Enable Benchmark menu _ 8 Sort menu and submenu items alphabeticially LJ E Hide icon and bubble in Notification Area Remember main window position V 1 Remember main window size Y Custom Variables _ Remember page menu state Y Content Filtering _ Remember last selected page E Custom Components C A Hide units e g Celsius KB Volt for measured values ye Asset Profile QD Display original CPU clock for mobile Intel processors e a Remote Features _ 73 Hide the best benchmark reference results useful on old computers ff Custom Programs File Scanner a A Network Alerting AA Alert Methods La Alert Triggers gt Q Hardware Monitoring Cancel Apply Enable ASPI page This option displays or hides the Storage ASPI page which shows information about ASPI devices In some very rare scenarios AIDA64 may lock up or cause an application fault when the ASPI page is opened In such cases disabling the ASPI page can resolve the problem Enable Audio Codecs page This option displays or hides the Multimedia Audio Codecs page which shows information about the available audio codecs This page may not be necessary when doing n
15. gt MY Operating System 4 Microsoft GSM 6 10 Audio CODEC gt E Server 4 Microsoft IMA ADPCM CODEC y e 4 Microsoft PCM Converter 4 Multimedia i ot Fiel ll Windows Audio nin bins i PCI PnP Audio 4 ACM Driver Properties A HD Audio 4 Driver Description Microsoft CCITT G 711 A Law and u Law CODEC 4 Copyright Notice Copyright c 1993 1996 Microsoft Corporation Driver Features Compresses and decompresses CCITT G 711 A Law and u Law audio data Driver Version 4 00 gt Network gt P DirectX gt Ey Devices gt fel Software gt M Security gt E Config gt EY Database gt 13 Benchmark 4 Audio Codecs li Local Copyright c 1995 2014 FinalWire Ltd Video Codecs This page provides information about the available video codecs Double clicking on any item will open the Sound window MCI This page lists the Media Control Interface devices SAPI This page provides information about the speech synthesis and speech recognition properties of the installed Microsoft Speech API SAPI Windows Storage This page lists the storage devices installed in the system including SATA IDE and SCSI controllers and the attached disk drives Physical information is provided for hard disks optical drives and SSDs Logical Drives This page lists the available local and network drives with information about the file system total size free spa
16. 10 4 SENE ae ee ee eo Oe ere eae ee eee eon ee eee ere 97 10 5 A a E sae 98 10 6 M timMmedid AA A y P o e 99 TUE e A A uence aaa N 100 10 8 A 102 10 9 e e 103 AIDA64 Business Contents 10 10 rn a a eee Oe eee ee 104 10 11 SO Wallet tela alli o 105 10 12 A ce teased A ETAO cn EI EEEE AE T EEEE T 106 10 13 AA erauessensanegioeeeaeeacees de ners ese eae 107 10 14 VATA AS Seah craic ia 108 10 15 JA PP toe a det eae ie teres Donen ean ean 108 11 Comtat idas 110 AIDA64 Business Introduction 1 INTRODUCTION AIDA64 Business is an IT asset management and remote monitoring tool for Windows With the application you can collect a very detailed hardware and software inventory from Windows client computers on your company network and monitor changes in both hardware and software It allows you to monitor and manage your Windows PCs remotely and it also offers hardware diagnostics and benchmarking functionality It is not necessary to install AIDA64 Business on each client separately as the application can be run from a central shared folder The software can be easily deployed in a corporate environment following the instructions in the Setup Guide downloadable from our website SYSTEM REQUIREMENTS Operating systems e Windows 95 98 Me e Windows Vista e Windows 8 1 e Windows NT4 2000 e Windows Server 2008 e Windows Server 2012 e Windows XP e Windows 7 e Windows Server 2012 R2 e Windows PE e Windows Server 2008 R2
17. In rare cases polling GPU sensors may cause system slowdowns or lockup 23 AIDA64 Business Preferences GPU fan speed measurement With this option we can control whether AIDA64 uses low level features to measure cooling fan speeds for AMD and NVIDIA video cards In rare cases polling GPU fans may cause system instability or automatic fan speed control issues Multi GPU support With this option we can control whether AIDA64 uses multi GPU features On AMD CrossFireX configurations including multi GPU AMD video cards like Radeon HD 5970 the ULPS power saving feature of the AMD Catalyst video driver may cause various issues while running AIDA64 In such cases multi GPU support has to be disabled to restore system stability Wake up GPUs at AIDA64 startup When we have more than one graphics processors in our computer AIDA64 may not be able to detect those devices that are deactivated by default for example on notebooks equipped with NVIDIA Optimus technology If we want the software to list all available GPUs we have to enable this option REPORT This page lists several options to customize the report creation process Search Report gt ia F Reporttitle AIDAG Business 2 enera ll Layout XML style file Gk Stability pA r a E7 Report _ Embed XSL in XML file o o 7 ae Pepe Poe _ 37 Enable report header E Report Look fo a _ 5 Enable report footer nit Schedule pod B FTP
18. Powers Clocks Statistics Start Stop Clear Save CPUID Preferences Close The stress test can be started and stopped using the Start and Stop buttons at the bottom of the windows By pressing the Clear button we can clear the graphs while the Save button can be used to take screen shots of the window lt is possible to launch the CPUID panel from here and open the Preferences menu 8 8 The AIDA64 CPUID panel provides detailed real time information about the processors When more processors or processor cores are available we can select the one the details of which we want to see By clicking Save we can take a screenshot of the window AIDA64 CPUID e NOZIO Processor QuadCore Intel Core i5 3450 Processor DualCore AMD Athlon II X2 250 Code Name Ivy Bridge DT A Code Name Regor Platform LGA1155 Platform Socket AM3 Stepping E1 L1 N0 PO ae Stepping DA C2 CPUID Vendor Genuinelntel 2 CPUID Vendor AuthenticAMD CPUID Name Intel R Core TM i5 3450 CPU 3 10GHz CPUID Name AMD Athlon tm II X2 250 Processor CPUID Rev 6 3A 9 Core Voltage 0 856 V CPUID Rev O1F 6 2 Core Voltage 1 504 V CPU Clock 1550 9 MHz L11 L1D Cache 32 KB 32 KB CPU Clock 803 6 MHz Lil LD Cache 64 KB 64 KB Multiplier 16x L2 Cache 256 KB Multiplier 4x L2 Cache 1 MB Bus Clock 96 9 MHz L3 Cache 6 MB HTT Clock 200 9 MHz Bus Speed L4 Cache HTT Speed 2009 0 MHz Instruction Set x86 x86 64 MMX SSE SSE2 SSE3 SSSE3 SSE4 1
19. Z CPU Utilization System gt 99 System gt 99 Ga Swap Space Utilization System gt 99 m Memory Utilization ii Custom Variables Content Filtering vg Ey Custom Components 55 Asset Profile gt AE Remote Features fi Custom Programs j File Scanner gt A Network Alerting a Hardware Monitoring Ga Drive C Utilization ca Drive D Utilization Motherboard A cru Bs CPU GT Cores BE PCH Diode ca KINGSTON SH103S390G ca WDC WD10EZRX 00L4HBO cpu System System Temperature Temperature Temperature Temperature Temperature Temperature Cooling Fan gt 99 gt 99 gt 60 gt 60 gt 70 gt 75 gt 55 gt 55 lt 500 baer A 33V Voltage lt 2 95 gt 3 65 gt osp 5v Voltage lt 4 50 gt 5 50 gt W Desktop Gadget lt 10 80 gt 13 20 gt Mi LCD E Q SensorPanel E Logging EY External Applications A i2v Voltage Delete Cancel Apply 61 AIDA64 Business Preferences 3 17 10 CORRECTION Here we can correct the displayed sensor readings Configuration We can add new items by clicking New edit existing items by pressing the Modify button or by double clicking items and delete items by clicking Delete Ratio This option configures the ratio to be applied on the selected item A ratio of 0 5 means effectively halving the input value A ratio of 2 0 means effectively doubling the input value Offset This option configur
20. network audit or remote control and in such scenarios disabling it can save up to 10 MB of system memory Enable Config menu This option displays or hides all pages under Config menu which displays certain Windows related information Enable Database menu This option displays or hides all pages under the Database menu which displays information about the installed database management software drivers and data sources Enable Benchmark menu This option displays or hides all pages under the Benchmark category Sort menu and submenu items alphabetically This option sorts the Page menu captions alphabetically This option may simplify navigation in the Page menu when a lot of pages are enabled Hide icon and bubble in Notification Area This option displays or hides the AIDA64 icon on the System Tray also known as the Notification Area This includes the bubble shown for specific events under Windows 2000 and later operating systems Alternatively there is a command line option SILENT to hide the AIDA64 icon and bubble Remember main window position AIDA64 saves and restores the main window position when this option is enabled The AIDA64 main window will always be displayed on the desktop centre when this setting is disabled Remember main window size AIDA64 saves and restores the main window size both width and height when this option is enabled The AIDA64 main window will be displayed using the default 800x6
21. reportfile El address SUE lt subject gt FTPUPLOAD reportfile RMTREPORT reportfile RMTHOSTS lt hostl host2 gt RMTREPORT reportfile RMTHOSTS lt listfile gt CS2HTM lt intile gt lt outfile gt CSV2SQL lt folder gt ALL SUM HW SW BENCH AUDIT CUSTOM lt profile gt TEXT HTML MAHTML XML ESV MIE INI DATABASE fACCEPT ACCEPTBG ACCEPTMIN LANGioa SAFE SAFEST NT4ZIPFIX SILENT SHOWED SHOWP SHOWPCANCEL SHOWS NOICONS INIFILE lt inifile gt DELAY lt seconds gt IDLE MOLICENSE Precautions please read below 1 Only one of the following options can be used in a single command line R E FTRUPLOAD RMTREPORT Mixing of these options with each other could lead to unexpected issues 2 Only one of the following options can be used in a single command line RMTREPORT ACCEPT ACCEPTEG ACCEPTMIN Mixing of these options with each other could lead to unexpected issues From Version 2 20 it is possible to use Report and Remote Connection options simultaneously in a single command line In such cases the report creation process will be launched first and after it is finished AIDA64 stays in the background waiting for incoming remote connections 86 AIDA64 Business Help Precautions 1 Only one of the following options can be used in a sin
22. sub pages where we can also find information about the ODBC Data Sources Page menu File View Report Remote Favorites Tools EST ZBE From Field Database Drivers E Borland Database Engine b Motherboard E Borland InterBase Client gt iF Operating System EF Easysoft ODBC InterBase 6 b E Server Ef Easysoft ODBC InterBase 7 p E ey EF Firebird Client EF Jet Engine fae EF MDAC Help Value E ADAG p gi Computer a Multimedia b a Storage 4 00 9765 0 6 3 9600 16384 winblue_rtm 130821 1623 e DirectX FF ODBC 6 3 9600 16384 winblue_rtm 130821 1623 b ag Devices MySQL Connector ODBC 5 2 6 0 gt El Software Z Oracle Client z gt Security E PsqlODBC gt EH Config EF Sybase ASE ODBC a EN Database Database Servers FF Borland InterBase Server EF Firebird Server Microsoft SQL Server EF Microsoft SOL Server Co l Local BENCHMARK Besides the comprehensive benchmarks described in section 8 1 and 8 2 AIDA64 offers dedicated microbenchmarks which are available under the Benchmark category in the Page menu These are synthetic benchmarks which means that they can be used to measure the theoretical maximum performance of the system Memory bandwidth CPU and FPU benchmarks are built on the multi threaded AIDA64 benchmark engine that since AIDA64 Business v4 00 supports up to 640 simultaneous processing threads and 10 processor groups Ef BDE Drivers EE ODBC Drivers
23. 17 AIDA64 Business Preferences When AIDA64 starts With this option we can configure the behavior of the AIDA64 main window after startup 3 2 2 NETUPDATE Check for updates Here we can set how often we want AIDA64 to look for updates A fully automated online update is only available when AIDA64 is activated with a valid product key and only until the expiry of the support period During the 30 day trial period or when AIDA64 is activated with a non genuine product key only a notification is sent about new product updates and a manual software update is required Available options are e Never e Once a day e Once a week e Once a month Update type This option can be used to select which updates to use It is not recommended to use beta updates for AIDA64 Business AIDA64 stable updates are released about 5 times a year Available options are e Stable updates only e Stable and beta updates Save update packages to local folder This option can be used to backup AIDA64 update packages to a local folder Besides the ZIP format update package a text file holding changelog information is also saved to the specified folder after a successful software update AIDA64 Business Preferences LAYOUT With the options available on the Layout tab on the Preferences window we can configure the user interface and the layout of AIDAG64 Search Y lt gt Enable ASPI page Y 4JEnable Audio Codecs page
24. 2000 XP 2003 MSJet OLEDB 4 0 v General 1 Layout CE Stability 4 7 Report Report File Default 8 Report Look a Schedule ber 5 Remarks Database SRVR2012 Shares AIDA64Business Reports DB Access mdb v ose 4 E mail User y SMTP JE Summary Custom Variables Y Content Filtering Ey Custom Components gt 55 Asset Profile a E Remote Features S Remote Control 3 a Security fay Custom Programs Password bJ File Scanner A Network Alerting E Hardware Monitoring Cancel 33 AIDA64 Business Preferences 3 7 4 MS SQL SERVER SQLOLEDB We can use MS SQL Server on both smaller and larger networks First open MS SQL Management Studio on our server and after connecting to the SQL server select the server authentication mode we want to use Windows Authentication mode or SQL Server and Windows Authentication mode By right clicking the Databases folder create a new database called AIDA64 Then right click on this database and start a new query using the DB SQL Server sql schema located in the AIDA64 SQL_Schema folder to create the required tables It is recommended to create a new user on the SQL Server To do this sea am expand the Security folder and right E gt Ep Provider MSSQL Server SQLOLEDB click on Logins then select New gt e a E Login On the General page add i ee the user name select SQL Server Mitos i BRE Authen
25. 3 Network Alerting afi Alert Methods SRVR2012 Shares AIDA64Business Frissit es hes AY Alert Triggers b Q Hardware Monitoring Cancel Apply 3 2 1 GENERAL Display AIDA64 in the Control Panel With this option we can display the AIDA64 icon in the Windows Control Panel so that we can launch AIDA64 directly from the Control Panel Load AIDAG64 at Windows startup With this option enabled AIDA64 will load automatically when Windows starts Display AIDA64 splash screen at startup With this option enabled AIDA64 will display the AIDA64 splash screen when the software starts Minimize button minimizes main window to System Tray This option changes the default behavior of the Minimize button to close the AIDA64 main window to the System Tray instead of the Taskbar Close button minimizes main window to System Tray This option changes the default behavior of the Close button to close the AIDA64 main window to the System Tray Icon style When this option is set to Windows XP or Windows 7 the relevant 32 bit alpha channel icons in the style of Windows XP or Windows 7 are displayed under Windows XP and later operating systems This feature is available only when the AIDA_ICONSXP DLL or AIDA_ICONS7 DLL file presents In most network audit situations the 32 bit icons feature should be disabled by removing both the AIDA _ICONSXP DLL and AIDA_ICONS7 DLL files to save memory and network bandwidth
26. 3450 Ivy Bridge DT CPU Platform Stepping LGA1155 E1 L1 NO PO 3292 5 MHz original 3100 MHz overclock 6 33x 99 8 MHz original 100 MHz 665 1 MHz 20 3 Intel Panther Point B75 Intel Ivy Bridge Chipset X58 SR5690 15520 287 Int Z77 Int C226 Int P67 SR5690 15400 X58 AMD990X Avoton AMD890Gx Int AMD970 B75 Int Pero a JENNY Ni BDLL 4 1 611 x64 CPU 3292 MH Copyright c 1995 2014 FinalWire Ltd 108 Memory Triple DDR3 1333 Dual DDR3 1600R Triple DDR3 1333 Dual DDR3 1600 Dual DDR3 1600 Dual DDR3 1600 Dual DDR3 1333 Unganged Dual DDR2 800R Quad DDR2 640FB Triple DDR3 1333 Dual DDR3 1866 Dual DDR3 1600 Unganged Dual DDR3 1333 Dual DDR3 1866 Dual DDR3 1333 Mood AAA ANA CL RCD RP RAS 9 9 9 24 CR1 11 11 11 28 CR1 9 9 9 24 CR1 9 9 9 27 CR2 9 9 9 24 CR2 11 11 11 28 CR1 9 9 9 24 CR1 6 6 6 18 CR1 5 5 5 15 9 9 9 24 CR1 9 10 9 27 CR2 11 11 11 28 CR1 9 9 9 24 CR2 9 10 9 27 CR2 9 9 9 24 CR1 fee 10 50m AIDA64 Business Page menu Thanks to AIDA64 s huge reference result database benchmark results can be compared to those of other configurations By clicking the Results button on the toolbar we can save and manage our benchmark results and we can also hide reference results and user results which are listed on the results page by default Memory read write copy and latency Memory benchmarks measure the maximum bandwidth achievable when performing
27. 55E4 2 AVX AES Instruction Set x86 x66 64 MMX MMX 3DNow 3DNow 3DNow Pro SSE SSE2 SSES SSE4A Motherboard MSI B75MA P45 MS 7798 Motherboard Gigabyte GA MA770T UD3 v1 BIOS Version V1 0 BIOS Version F2 Chipset Intel Panther Point B75 Intel Ivy Bridge Chipset AMD 770 AMD K10 Integr Video Active Intel HD Graphics 2500 Integr Video Memory Type Dual Channel DDR3 1292 SDRAM 9 9 9 24 CR1 Memory Type Unganged Dual Channel DDR3 1071 SDRAM 8 8 8 20 CR1 Memory Clock 646 2 MHz DRAM FSB Ratio 20 3 Memory Clock 535 7 MHz DRAM FSB Ratio 16 6 CPU 1 Core 1 y Save Close CPU 1 Core 1 v Save Close 83 AIDA64 Business Help 9 HELP In this menu beside the Help file we find links to online support resources the end user license agreement product information and we can also choose to enter the product key here AIDA64 HELP AIDA64 Help F1 opens the main page of the AIDA64 help file user manual You can select topics in the contents page or search for any term File View Report Remote Favorites Tools gt t 2 E Report 2 AIDAS Help Ej AIDAG4 Online 22 AIDAG4 Forum anaes ME computer Contact LJ al Ll p 1 Computer Motherboard License y chipset BIOS information gt i Motherboard E Operating System kses drivers information Y Operating System 3 Server GY Command line Options a ee E Display Ws Enter Product Key dp information pay Multimed
28. 7 POO GWG mola 57 3 17 8 Extrnal application S raros aa eA e 58 3 17 9 PALS A A E 61 SO GONE CU irradia didas 62 4 A A acess uesaseusuee saumebesaseodsusscsessseseccuseemenuasenesinn 63 9 AIDA64 Business Contents REDONU O o nec suncec eases E 64 5 1 PRODI Vy Ol yates a le posse soaens allege altuie yan ll eeoea a a seas ueeseemeaauueinmoties 64 5 1 1 Report DIOUIES 521k ras Sinincushiatusactbacusdveestuvardtmanauehd A 65 5 1 2 Repon AAA o CO O 66 52 OUICKI CPO anen a a 66 5 3 Submit repo to AMS os 67 5 4 mis ee io alo IAEA POE o E E 67 5 5 Remote TED OM WIZ oa 68 5 6 REDOVE W naa II A 68 Remote reatUre S aiii id a MMe dia laetl emedaley 69 6 1 Remote Mont ios 69 6 1 1 Pror ONO E urticaria toa ici 71 6 2 Remote ys AO dd 72 6 3 nn Selhe antes acento etesbecthac ibeansas eceandaeeecads 73 6 4 Accept Incoming Remote Connections ccccccccccccessseeeceeeeeeeeeeeeeeceeeeeesseeeeeeeeeeesssaeaeeeeeeeeesaaas 73 6 5 Ignore Incoming Remote CONNECTIONS cccccecccccescecceeececeesecccsuseecseeseeecseuseeeseuseeessaseeessaaees 73 Favor ES saree o O N 74 TOONS ii E a suceusaestecedsssateuticesadusbiecacupeeeeemulenwsactes 75 8 1 ISS IC I A hustaustranndctatenniaed ce asta eicuaseamndoseemntue toeeiat 75 8 2 Cache and Memory benchmark Redes ell het a E eee ake 76 8 3 A score cctbonsenaatetaceinicera nid iecetke menaced atkaniceoned ivandeceamceneate E 77 8 3 1 The GPGPU Benchmark Panel s user interface oocccccc
29. Audit Filter 2 Filter PCI Device list enter keywords On the Filter tab we can filter the list of PCI and USB devices as well as installed programs using keywords These data are found in lists and Statistics Realtek Filter USB Device list enter keywords Generic Filter Installed Programs list enter keywords AIDA64 On the Components tab we can choose the component categories we would like to see in the inventory lists and statistics The components we deselect will not be visible in the list General Filter Components Summary Audit Components M Audit Components gt A HW Components b B SW Components O Custom Variables 2 DMI Components M BE DMI BIOS Vendor MBE DMI BIOS Version MM DMI System Manufacturer M il DMI System Product of IM DMI System Version M il DMI System Serial Number A Ml DMI System UUID DMI Motherboard Manufacturer DMI Motherboard Product A 8 DMI Motherboard Version DMI Motherboard Serial Number 0 DMI Chassis Manufacturer O DMI Chassis Version O DMI Chassis Serial Number O0 DMI Chassis Asset Tag O DMI Chassis Type 10 AIDA64 Business General Filter Components Summary Summary A 1 Computer l Computer Type ay Operating System O a OS Service Pack LJ e Internet Explorer O e DirectX Computer Name E User Name O SMTP E
30. Business Preferences CUSTOM COMPONENTS Custom Components can be used to specify such hardware components that cannot be detected using conventional hardware auditing methods The information about pre configured Custom Components will appear on the Computer Summary page We can add custom components to individual computers or if we write ALL in the computer name field or press the All button to all computers in the network at once 4 7 Report i Report File Report Look 0 Schedule EA Custom Variables Y Content Filtering E Custom Programs D J File Scanner gt A Network Alerting D Q Hardware Monitoring Custom Components 3 Field F Chassis j OFFICE104 3 Power Supply CPU Cooler CPU2 Cooler Value CHIEFTEC CD 01 B B350 CODEGEN 350W Meco F Chassis CHIEFTEC CD 01 B B350 Power Supply CODEGEN 350W CPU Cooler CPU2 Cooler 0 System Cooler System Cooler System Cooler System Cooler System Cooler System Cooler Ey Misc Device Ey Misc Device E Misc Device El Misc Device IN ASSET PROFILE The Asset Profile feature can be used to specify such properties of a computer user that cannot be detected using conventio
31. EF ODBC Data Sources t ay Benchmark Copyright c 1995 2014 FinalWire Ltd 64 File View Report Remote Favorites Tools Help lt y t e w Bi Report 4 Parameters Results Menu Favorites E ADA64 b lil Computer gt Motherboard gt ey Operating System b E Server gt A Display gt a Multimedia b Storage gt P Network gt DirectX gt El Devices gt El Software gt ME Security b ES Config gt EY Database 4 73 Benchmark mm Memory Copy 5 Memory Latency TA cru Type A cpu Clock A CPU Multiplier CPU FSB m Memory Bus m DRAM FSB Ratio BE Motherboard Chipset off FPU SinJulia Queen 10 10 0 20 sec 4 CPU HT off mask F lar x Core i7 4770 HT paa Ja Core i7 3770K HT 45915 JaxXeonE3 1245v3HT 43907 4xCorei7 2600HT 37778 x Core i7 965 Extreme HT 6089 meso 34010 8x Atom C2750 amp Phenom II X6 Black 1100T 8x FX 8150 CPU Clock 3466 MHz 2200 MHz 2666 MHz 3400 MHz 3500 MHz 3400 MHz 3400 MHz 2400 MHz 2800 MHz 3200 MHz 4000 MHz 2400 MHz 3300 MHz 3600 MHz 3300 M RANN AAI I Motherboard Intel DX58502 Supermicro H8DGI F Supermicro X8DTN Intel DZ87KLT 75K MSI Z77A GD55 Supermicro X10SAE Asus P8P67 Supermicro H8DI3 F Intel 554005F Asus P6T Deluxe Asus M5A99X Evo R2 0 Supermicro A1SAi 2750F Gigabyte GA 890GPA UD3H v2 Asus M5A97 MSI B75MA P45 MS 7798 T Ti_ J TENA QuadCore Intel Core 15
32. If we launch AIDA64 using the SAFE or SAFEST command line options we can disable some critical low level hardware detection functions to ensure system stability Search Stability al Load kernel driver 27 QO Low level MSR operations may cause system lockup in rare cases Low level PCI bus operations may cause system lockup in rare cases ME Low level SMBus operations may cause system lockup in rare cases iE Low level sensor operations may cause system lockup in rare cases E 0 Report Look Fan divisor reconfiguration might conflict with MSI Core Cell and PC Alert meo Schedule Ga Low level SMART operations may cause system lockup in rare cases lt gt RAID member enumeration Remarks lt gt RAID SMART support y LP E mail 3 nVIDIA GPU SMBus access through nVIDIA ForceWare las Es SMTP amp Change to 3D profile on nVIDIA video adapters B SMBus access through ACPI Asus motherboards ME Apple SMC sensor support ME Asus ATKEX sensor support Asus ROG FE Dell SMI sensor support Ey Custom Components 3 HID UPS sensor support 2 za Asset Profile BE Koolance TMS 200 sensor support ME Remote Features fg Custom Programs gt J File Scanner 4 Network Alerting ME T Balancer sensor support E DIMM thermal sensor support ME Toshiba TVALZ sensor support E Volterra VT11x sensor support wv gt E Hardware Monitoring Cancel Apply Load kernel driver In most cases stability iss
33. NO Norwegian AL Albanian FR French PL Polish BG Bulgarian HR Croatian PT Portuguese BS Bosnian HU Hungarian RO Romanian BY Belarusian ID Indonesian RU Russian CA Catalan IT Italian SE Swedish CN Chinese Simplified JP Japanese SI Slovenian CZ Czech KR Korean SK Slovak DE German LT Lithuanian SR Serbian DK Danish LV Latvian TR Turkish EN English MK Macedonian TW Chinese Traditional ES Spanish NL Dutch UA Ukrainian 9 6 8 e SAFE This option activates safe mode in which low level PCI SMBus and sensor scanning are disabled For network audits it is recommended to use this option to make sure AIDA64 does not cause system stability issues e SAFEST This option activates the safest mode in which kernel drivers are not loaded either e NT4ZIPFIX Using this option an lomega Zip drive related issue can be avoided on Windows NT 4 0 systems 9 6 9 e SILENT This option can be used to hide the AIDA64 icon on the System Tray also known as Notification Area and the bubble notifications e SHOWED Using this option displays a dialog box before the report is sent in e mail This can be useful in help desk scenarios as the dialog box lets the user enter special comments about his her issue This option must be used with the E command line option e SHOWP Using this option the report creation progress can be tracked on screen but no user i
34. OLEDB 4 0 0 cccccccccsssseeeccceesseeecceeesseeesceeaseceeessaaeeeeesseaseeeesssaseeess 33 3 7 3 MS Access 2000 XP 2003 MS Jet OLEDB 4 0 coooncccccccccoccncccccooncnnncccooccnnnnnconnonnnonononons 33 3 7 4 MS SOL Server SOLOLBDD persa orita 34 3 7 5 WySOLAMSDASQL noria etario iaa toi paciencia 35 AIDA64 Business Contents 3 7 6 ODBC MSDASOL ssk les do 38 3 7 7 Oracle MSDAORA oinin ir r aa a a t dolce 39 3 7 8 PostgreSQL MSDASQL cccoccccccoooooonononnnnnnonononnnnonononononononononnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 40 3 7 9 Sybase SybaseASEOLEDBProvider rrei a E 40 3 8 S a A 40 3 9 Custom Vanale S aranan E E A ates oats 40 3 10 Sci E OE o ee renee eee eee eer nme aa ee rer eer eer ena reer 42 3 11 CUSTOM CIN Sd ch cass barker dd os 43 Hi Ps ASS PEON cane enn a ne a Rn eR en a mee ee eee 43 313 REMOS O UNS ls Etre 44 3 13 1 BOMO CONIO aaa ER a AE sdvusuenenendeoeei ds 44 3 13 2 SA SE erie a E N E E toeeeee 44 3 14 CUINA e e le head 45 3 15 PIS GLI MIM pet OP On A e teet aa tea eeannduenesesnpen eeaatan Gesantoueneate 46 3 16 NetWork ale asusta 47 3 16 1 A A aes aterper ete bi aber 48 3 16 2 Alert OO it AA A NAAA A aed Middatcdde 49 Sit Hardware Montoro ito ON 50 3 17 1 Mc A O adese tack AA a 51 3 17 2 SEMSOMICONS aa 51 3 17 3 caielate dented ta caccbos tanta ta asthe iden Add etlboeteea 52 3 17 4 DESKIOM GAO SUS esse soca iii 53 3 L729 A A lk A eee ela 94 3 17 6 SEAS OPM lina ita 56 3 17
35. Summary f Chassis CHIEFTEC CD 01 B B350 Computer Name Power Supply CODEGEN 350W A Y DMI EY Operating System Microsoft Windows 8 1 Professional E PMI 3 OS Service Pack a Internet Explorer 11 0 9600 17207 DirectX DirectX 11 2 E Computer Name OFFICE103 a User Name oliver mesztrics fe isc Sickie s Logon Domain ABSEIRA Motherboard i 3 Server ES Date Time 2014 07 14 09 15 l gt A Display he ra Multimedia gt Motherboard b Storage A cru Type QuadCore Intel Core 5 3450 3500 MHz 35 x 100 b EF Network Motherboard Name MSI B75MA P45 MS 7798 1 PCI 1 PCI E x1 1 PCI gt 3 DirectX ME Motherboard Chipset Intel Panther Point B75 Intel Ivy Bridge gt y Devices m System Memory 8064 MB DDR3 1333 DDR3 SDRAM D are Kingmax 9 9 S gt fe Softw m DIMM1 K FLGF65F D8KQB 4 GB DDR3 1333 DDR3 SDRAM 9 9 9 24 666 M b AW Security m DIMM3 Kingmax FLGF65F D8KQB 4 GB DDR3 1333 DDR3 SDRAM 9 9 9 24 666 M gt EH Config HE BIOS Type AMI 03 26 2012 gt EF Database Communication Port Kommunik ci s port COM1 gt 1E Benchmark Communication Port Nyomtat si port LPT1 v jm Summary jm Local Copyright c 1995 2014 FinalWire Ltd Clicking on the items highlighted in blue on the page will open a context menu which provides links to the manufacturer s product information page as well as to BIOS and driver download websites Computer name The Windows host name the N
36. Windows XP and Windows 8 to enable them Vista 5744 Sidebar for XP and oGadgetPack Gadgets for Windows 8 respectively 64 AIDA64 Business When the option Use HKLM in Registry is enabled AIDA64 stores measured temperature voltage and fan speed values in the root key HKEY_LOCAL_MACHINE in the Registry Otherwise the values are stored in the root key HKEY_CURRENT_USER CPU 2121 RPM We can customize the layout of the desktop gadget by clicking the wrench icon that appears when we hover the mouse over the gadget itself It will display the options window where we can configure how we want to align the text and we can choose to break up long texts into multiple lines If the latter option is disabled long lines may not be fully visible in the gadget We can also enable disable the AlIDA64 Business header and the labels We can customize the gadget colors either by selecting a predefined color theme or by defining the background top background bottom header text and border colors manually 53 AIDA64 Business Preferences 3 17 4 1 Desktop gadget items Here we can select the items we want to display on the Desktop gadget Double clicking or selecting an item will display the settings window for the item where we can customize its layout Here we can modify the default label or restore it select the font and configure the font size font color and font property for the displayed text 3 17 5 LCD AI
37. are compressed using ZIP before they are saved to file Compress reports before sending in e mail When this option is enabled reports are compressed before they are attached to the e mail Compress reports before uploading to FTP When this option is enabled reports are compressed before they are uploaded to the FTP server Full name This option specifies the name that appears in the From field of outgoing e mail messages E mail address This option specifies the e mail address that appears in the From field of outgoing e mail messages 26 AIDA64 Business Preferences 3 5 1 REPORT FILE Output folder This page lists several options to configure report file creation Among other things we can specify the default output folder for saving reports this is where reports will be saved if we do not define a path in the command line During network audit this folder should be a UNC path for example server share folder and all users should only have write permission to this folder We can use the following variables in both the output folder name and the file name e HOSTNAME Inserts host name e USERNAME Inserts current user name e DOMAIN Inserts current logon domain e IPADDR Inserts primary network adapter IP address aaa bbb ccc ddd e MACADDQ Inserts primary network adapter MAC address AABBCCDDEEFF e MACADDR Inserts primary network adapter MAC address separated by hyphens AA BB CC DD E
38. but they cannot be used in AIDA64 Audit Manager and Change Manager CSV reports will be created in CSV Comma Separated Values format CSV reports can be used in AIDA64 Audit Manager and Change Manager or can be processed by any other 3rd party solutions The default column separator character for CSV reports comma cannot be changed MIF reports will be created in MIF format MIF reports can be used for MS SMS integration MIF reports always include the same static information block regardless of the specified report profile ANI reports will be created in INI format INI reports can be used by scripting languages but they cannot be used in AIDA64 Audit Manager and Change Manager DATABASE reports will be inserted to a SQL database SQL connection parameters can be configured in Preferences Database 9 6 6 REMOTE CONNECTION ACCEPT This option enables incoming connections ACCEPTBG Using this option AIDA64 will be launched in the background and wait for incoming remote connections The user on the client machine cannot use or close AIDA64 ACCEPTMIN Using this option AIDA64 will be launched in the background and wait for incoming remote connections The user on the client can use and close AIDA64 89 AIDA64 Business Help 9 6 7 LANGxx where xx should be replaced with a 2 letter language code The following languages are currently supported AA Arabic Fl Finnish
39. can access the AIDA64 diagnostics modules 8 1 With this module we can measure the performance of the PC s storage devices including S ATA or SCSI hard disk drives RAID arrays optical drives solid state drives SSD USB drives and memory cards lt also allows us to perform write tests which helps us detect fake products and errors on the devices In order to attain reliable benchmark results we have to make sure to close all background applications File Options Average Read Access Average Read Access Disk Drive 0 WDC WDTOJPWT 2241YT0 931 5 GB Current 18 61 ms Minimum 15 60 ms Maximum 25 79 ms Average 17 37 ms CPU Current O CPU Minimum 0 CPUS Maximum 6 CPUS Average 2 Block Size 64KB Start Stop Save Clicking Save we can save the results as a PNG image while by pressing the Clear button we clear the results and restore the window to its default state In the Options menu the following settings are available Block size Here we can select the block size the benchmark engine uses to test the storage device The smaller the block size the more time it takes to complete the test Loop mode In loop mode the benchmark will restart every time it has been completed Display performance in KB s We can change the data throughput measurement unit from MB s default to KB s 19 AIDA64 Business Tools Write tests If we enable write tests the following additional
40. file P E mail Description Aida64 bench64 dil ii Bl e AE SMTP Folder WISRVR20121Shares AIDA64Business HEE Database Ml Summary File Name aida_bench64 dil y Custom Variables Y Content Filtering on Ey Custom Components ye Asset Profile 4 15 Remote Features 4 Remote Control afi Security p r J File Scanner D A Network Alerting gt E Hardware Monitoring File Size 4093248 Folder name may contain one of the following control strings SSYSTEMDRIVE SPROGRAMFILES SWINDOWSDIR SSYSTEMDIR SALLDRIVES Modify Delete OK Cancel Apply e If we select Check if a specified file in a specified folder exists we need to specify a folder name and a file name as well as the file size in bytes optional This method can be used to check the existence of a file in a folder when both the file name and folder path are known Example To detect Oracle R8 1 installation it is possible to check for the existence of the file called oraclient8 dll in the folder c oracle ora81 bin e The option Check if a specified folder exists can be used to check the existence of a folder when its path is known For example to detect Oracle R8 1 installation it is possible to check for the existence of the folder called c oracle ora81 bin Note This method detects existing folders even when they are empty ie no files are found in the folder e The option S
41. gt Motherboard lt label gt lt value gt 45 lt value gt lt bemp gt chermp gt cid gt TCPU s fid gt label CPU lt label gt lt value 235 lt value gt attemp chemp gt lt id gt TOC 1 1 lt fid gt label gt CPU 41 Core 1 lt label gt lt value gt 50 lt walue gt lt tempo chemp gt id TOC 1 2 lt fid gt lt label gt CPU 1 Core 2 lt label gt lt value 58 lt value gt lt fbemp gt chemp gt lt id gt TNB lids lt label North Bridge lt label gt lt value gt 62 lt yalue gt lt lbemp gt temp gt lt id gt TGPU1 lt fid gt lt label gt GPU lt flabel gt lt value gt 67 lt yalue gt lt bemp gt hemp gt lt id gt THDD1 lt fid gt label 5T332062045 lt label gt lt value gt 34 lt P value lt kemp gt temp gt id gt THO id gt label gt 57332062045 lt label gt lt value 235 lt value gt lt temp Fan gt tid gt FOPU stid gt label gt CPU lt flabel gt lt value gt 1450 lt yalue gt lt Fan gt Fan gt tid FS S lt Jid gt lt label gt System lt label gt lt value gt 1700 yvalue gt lt Fan gt lt yvolk gt id gt ViCPU lid gt lt label gt CPU Core lt label gt lt value 21 22 lt yalue gt lt yvolk gt yolks cid gt Y PSY lids lt label 5 V lt ilabel gt lt value gt 5 00 lt value gt siot gt geyol cid gt VP12V lt lid gt lt label 12 V lt flabel gt lt yalue gt 127 16 lt yalue gt lt yolk gt volts lt id gt VBAT lt fid gt lt label gt VB4T Bat
42. its layout Here we can modify the default label or restore it select the font and configure the font size font color and font property for the displayed text Search D 37 Report gt LP E mail EF Database Ml Summary Y Custom Variables Y Content Filtering Custom Components 55 Asset Profile gt ME Remote Features ff Custom Programs File Scanner D Network Alerting a Q Hardware Monitoring med 7 Update Frequency gt Ml LCD E Q SensorPanel g Logging ie External Applications sso A Alerting OSD Items OSD Item DIA cru 1 Core 2 cpu Motherboard o CPU Core A cru OM cru vip O a CPU Package O a CPU IA Cores KE CPU GT Cores OM cpu 1 Core 3 OI cpu 1 Core 4 _ EE PCH Diode A 33V A 5v A 12V CI VBAT Battery O A 3 3 V Standby O DO CPU Package O cru IA Cores E CPU GT Cores O A cru Uncore Type Temperature Cooling Fan Temperature Voltage Temperature Voltage Temperature Temperature Temperature Temperature Temperature Temperature Voltage Voltage Voltage Voltage Voltage Power Power Power Power Select All Clear All Configure OK Move Up Cancel 3 17 4 DESKTOP GADGETS Here we can choose to display sensor values on a Desktop gadget Desktop gadgets are natively supported in Windows Vista Windows Server 2008 and Windows 7 while an extension pack needs to be installed in
43. name to get a description about it and to see a small thumbnail about the test screen instead of running all the tests The test can be run in automatic or manual mode In automatic mode the selected test screens will be displayed one after the other as in a slide show until Esc is pressed In manual mode we can proceed to the next test screen by pressing the Space or Page Down button In this mode hints are provided for each test screen regarding what we need to pay attention to The module contains a predefined test setting for LCD displays which can be selected in Selection Test for LCD monitors on the menu bar 81 AIDA64 Business Tools ULLAL nn AAA AAA OOOO POET LEEREELEEEE DIERAN EINER ELA ERA RE RAA EE TEEE PEQREEREALALE ALA RRALE TRE RERRAAE RANURA RRA RARA ERA li TU LCD Calibration Screen Ideal test screen for automatic calibration on LCD panels with analog connector cable In Preferences we can choose to save the test selection upon exit in case we want to run the same tests next time We can also define how often the test screens should follow each other and we can select multi display mode On PCs with more connected displays it is possible to test the monitors with the same test images on each or with a single test image stretched through all General settings Save tests selection state on exit Automatic Mode Show each test screen for 4 seconds Multi display mode g In multi d
44. need to run the following command on the SQL Server This will open port 1433 netsh advfirewall firewall add rule name SQL Server dir in action allow protocol TCP localport 1433 34 AIDA64 Business Preferences 3 7 5 MYSQL MSDASQL We need to install the MySQL service on our server in this case XAMPP and then add a new user We need to enter a user name and a password then select Any host We can also create a database here with the same name and grant all privileges Finally we have to click on the Create user button Add user Login Information User name Use textfield M aidab4 Host Any host hd pz Password Use textfield v Re type TILLI Generate password Erinin Database for user Create database with same name and grant all privileges Cl Grant all privileges on wildcard name username 9 We need to revoke any extra user privileges preserving only those which they will require to perform modifications necessary for report creation Global access rights to MySQL should be left as they are USAGE but we need to modify database specific privileges which we can do by clicking the Edit privileges link 35 AIDA64 Business Preferences In the Edit privileges User aida64 Database aida64 window we have to locate Database specific privileges and click on Uncheck all then in the Data column we need to check the privileges we want We must sel
45. normal 4 Multimedia 03 Spinup Time 21 144 139 3800 OK Value is normal l Storage 04 Start Stop Count 0 100 100 162 OK Always passes e 200 200 0 OK Value is normal 100 253 0 OK Always passes 100 100 OK Always passes 100 100 OK Always passes 100 253 OK Always passes 100 100 OK Always passes 200 200 OK Always passes 200 200 OK Always passes 107 OK Always passes 200 200 OK Always passes 200 200 OK Always passes 100 253 OK Always passes 200 200 OK Always passes 100 253 OK Always passes 3 Eg Windows Storage 05 Reallocated Sector Count 3 Logical Drives 07 Seek Error Rate y Physical Drives 09 Power On Time Count 8 Optical Drives OA Spinup Retry Count OB Calibration Retry Count OC Power Cycle Count CO Power Off Retract Count C1 Load Unload Cycle Count gt DEK C2 Temperature k Devices C4 Reallocation Event Count d E ES C5 Current Pending Sector Count a Config C6 Offline Uncorrectable Sector Count C7 Ultra ATA CRC Error Rate F Database gt Benchmark C8 Write Error Rate cy SMART li Local Copyright c 1995 2014 FinalWire Ltd oo oo o oo ogo oO Oo e O amp o 101 AIDA64 Business Page menu NETWORK Windows Network This page enumerates the wired and wireless network adapters installed such as integrated WLAN controllers motherboard integrated LAN controllers and Bluetooth controllers The page provides network adapter properties including real time traffic information Links
46. on the motherboard PCI Devices This page lists the PCI PCI Express and AGP devices and provides detailed information about the AGP HyperTransport PCI Express and QPI controllers Links to the manufacturers driver download websites are provided at the bottom of the page USB Devices This page lists the available USB controllers and USB devices The USB controller icons are color coded USB 2 0 controllers are displayed in violet while USB 3 0 controllers in blue Device Resources This page lists the resources port IRQ DMA memory used by Windows devices Input This page lists the input devices keyboard mouse game controller and their properties Printers This page lists the installed local and network printers and faxes along with their properties Links to the manufacturers driver download websites are provided at the bottom of the page 104 AIDA64 Business Page menu SOFTWARE Auto Start This page lists the programs which are launched at Windows startup Double clicking on any of these items will open their file properties window while clicking Remove on the toolbar will remove the items from the list and will not launch at Windows startup File View Report Remote Favorites Tools Help e gt t 2 MU Ey Report PX Remove Menu Favorites Application Description Start From Application Command E AIDA64 23 Dropbox StartMenu User C Users Default AppData Roaming Dr E Computer eg
47. the selected operations read write copy The memory latency benchmark measures the time it takes for data to arrive in the integer registers of the CPU after the issue of the read command CPU Queen This simple integer benchmark focuses on the CPU s branch prediction capabilities and branch misprediction penalties It calculates solutions for the classic N queens puzzle on a 10x10 chessboard CPU PhotoWorxx This integer benchmark measure CPU performance with several 2D photo processing algorithms The test mainly stresses the SIMD integer arithmetic execution units of the CPU and the memory subsystem CPU ZLib This integer benchmark measures combined CPU and memory subsystem performance using the public ZLib compression library CPU AES This integer benchmark measures CPU performance using AES Advanced Encryption Standard data encryption CPU Hash This integer benchmark measures CPU performance using the SHA1 hashing algorithm FPU VP8 This benchmark measures video compression performance using version 1 1 0 of the Google VP8 WebM video codec FPU Julia This benchmark measures the single precision or 32 bit floating point performance through the computation of several Julia fractal frames FPU Mandel This benchmark measures the double precision or 64 bit floating point performance through the computation of several Mandelbrot fractal frames FPU SinJulia This benchmark measures the exten
48. 0 00 oll OFFICE 103 AIDA64 v4 2014 03 24 8 24 00 E OFFICE 104 outdated AIDA64 v4 2014 03 17 13 52 00 SSSS5555S5 55558 IIE E El El E E E E ES ls ES El El EE Es ES 102 reports jE 19 computers E 1 users If we look at reports collected from a given PC a label saying outdated may be displayed along with the e il d View name of the computer which indicates that there is a more recent report available It is possible to hide a El Refresh outdated reports from the list by deselecting Show e a User outdated reports on the View menu Mi OFFICE101 outdated prem E OFFICE101 outdated admin E OFFICE101 outdated admin Database Manager can be configured in its Preferences menu We can customize the layout by choosing to display or hide the grid lines General Insert Report Files to Database gt _ Use file name instead of computer name ES A C Only insert the lines used by Audit Statistics Delete inserted report files after successful insertion Layout ra Show grid lines 12 AIDA64 Business File menu We can export a selected report or reports to a CSV file or open them as an HTML file lf we do not need our outdated reports anymore we can delete them just as with any report that we select We can also change the state of a report from unfinished File Edit View gt Refresh 3 EL Insert Report Files to Database ad Export Selected Reports
49. 00 window size when this setting is disabled Remember page menu state AIDA64 saves and restores the page menu state when this option is enabled Page menu state means the expanded or collapsed state of each menu item in the page menu Remember last selected page AIDA64 displays the last selected page when this option is enabled Hide units e g Celsius KB Volt for measured values This option hides the measurement units on the Sensor page This option could be used during network audit when the measured temperatures voltage values etc are post processed and so the measurement units would make it more difficult to process the measured values 20 AIDA64 Business Preferences Display original CPU clock for mobile Intel processors Due to the Intel SpeedStep CPU throttling technology the actual clock speed of a CPU may vary This option should be enabled during network audit when the original CPU clock speed has to be reported Hide the best benchmark reference results With this option we can hide the top half of the scores in the benchmark reference results list which may be useful on older computers STABILITY In this menu we can enable or disable the low level hardware detection modules of AIDA64 some of which can cause system hang ups in rare scenarios When experiencing stability issues these options can be used to make AIDA64 work properly These low level modules can be disabled from the command line too
50. 13699 MB s 13626 MB s 13701 MB s 42 62 GFLOPS 39 72 GFLOPS 42 62 GFLOPS 22 32 GFLOPS 42 39 GFLOPS AT AT fl ANC Run Time Build Time If you happen to have two GPU devices and you disable the CPU test by unchecking its checkbox the panel will switch to dual GPU mode where the first column is used for displaying results for GPU1 and the second for GPU2 If you want to see the combined performance of both GPUs just check the CPU checkbox again after the benchmark has been completed and the interface will switch back to the default layout 19 AIDA64 Business Tools ACPI BROWSER The Advanced Configuration and ACPI Browser AIDAGA z Power Interface ACPI specification provides an open standard for device configuration and power management by the operating system a JE Root We can save either the tree or the Eo a ee e ee DSDT Differentiated System a aac Description Table or the entire table to a text file while double clicking any item will display the EL code We can search in the item tree and perform custom queries DRAM TIMINGS This window provides extremely detailed DRAM timing information much more than what is available on the Motherboard SPD page Slot DIMM1 Kingmax FLGF65F D8KQB Timing 16 Memory Clock A Memory Voltage A Memory Ctrl Voltage m CAS Latency E RAS To CAS Delay E RAS Precharge m RAS Active Time E Row Cycle Time E Row Refresh Cycle Time m Comman
51. 3 E User Name oliver mesztrics Network 5 Logon Domain ABSEIRA 9 Date Time 2014 07 11 09 52 Storage Sensor DirectX Devices Motherboard A cpu Type QuadCore Intel Core i5 3450 3500 MHz MSI B75MA P45 MS 7798 1 PCI 1 PCI Security DIMM Audio Video Gigabit LAN NE Motherboard Chipset Intel Panther Point B75 Intel Ivy Bridge Config ma System Memory 8064 MB DDR3 1333 DDR3 SDRAM mm DIMM1 Kingmax FLGF65F 4 GB DDR3 1333 DDR3 SDRAM 9 9 9 24 amin 592 MHz 7 7 7 19 Software Motherboard Name 2092 KB 25 AIDA64 Business Preferences Include debug information in TXT HTML MHTML reports When this option is enabled a dump of PCI registers and video BIOS appears at the end of TXT HTML MHTML reports Debug information is important when contacting AIDA64 Technical Support with hardware detection issues so please make sure to enable this option before submitting any reports to AIDA64 Technical support Include debug information in CSV reports When this option is enabled PCI devices are listed in a post processable format at the end of CSV reports Show computer name in caption of the first report page When this option is enabled the computer name is displayed in the caption of the Computer Summary page in the reports This option is useful when HTML or MHTML reports are printed or filed and the report header is disabled Compress reports before saving to file When this option is enabled reports
52. 6 testing modes become available Linear Write Random Write Buffered Write Avarage Write Access Linear Write Verify and Random Write Verify When performing write tests all data will be lost on the storage device and AIDA64 warns us three times of this when launching the process Performance monitor To the right of the charts we can find the performance monitoring table where we can follow in real time the current minimum maximum and average read speeds as well as the current minimum maximum and average CPU usage in percent as well as the block size used in the test CACHE AND MEMORY BENCHMARK This benchmark measures the bandwidth and latency of the CPU caches and the system memory By double clicking any rectangle column or row in the window we can launch benchmarks or benchmark types individually For example if we double click Memory only system memory read write copy and latency benchmarks will be run that is only the operations in the given row are executed Similarly if we double click Read only read benchmarks will be run on all memory types that is only the operations in the given column are executed If we double click any rectangle only the selected single benchmark will be run Right clicking the Start Benchmark button will open a context menu in which we can choose to run all benchmarks or just the memory or cache benchmarks AIDA64 Cache amp Memory Benchmark e x Read Write Copy L
53. A LCD Items E SensorPanel E Logging nm TE TE EE Ey External Applications Ay Alerting i E Correction OK Cancel Apply 54 AIDA64 Business Preferences 3 17 5 1 LCD items Here we can select the sensor items we want to see on the LCD display as well as their layout We can add the items we would like to display to a list and modify hide copy or delete existing ones Using the arrows on the right we can move and position items on the LCD display one pixel at a time A preview of the LCD screen is shown in the upper left corner of the window When we press the Apply button the items will instantly appear on the LCD display AIDA64 is capable of displaying multiple a maximum of 4 pages of sensor items on the LCD Individual pages are accessible by clicking on the page tabs at the top of the sensor item list We can also customize the sensor item layout among other things we can set the font and the font size and add a shadow effect As very small fonts are not readable on the LCD the recommended smallest font size is 8 pixels We can modify the default item label and customize the label layout color font style shadow Naturally we can only choose colors for color LCD equipped devices such as the Logitech G19 Gaming Keyboard Other configuration options include setting the text alignment LCD items are aligned to the left by default and enabling disabling the display of measurement units next to
54. ACPI This option can be used on Asus motherboards to avoid collisions between the AIDA64 hardware monitoring module and Asus own hardware monitoring and overclocking applications e g Asus Al Booster Asus Al Suite Asus PC Probe ll Asus SixEngine etc This option must not be enabled on PCs with non Asus motherboards Apple SMC sensor support With this option we can control whether AIDA64 uses low level features to measure temperatures and cooling fan speeds via Apple SMC sensors In rare cases polling the Apple SMC sensor device may cause system instability 22 AIDA64 Business Preferences Asus ATKEX sensor support Asus ROG With this option we can control whether AIDA64 uses low level features to measure temperatures and cooling fan speeds via Asus ATKEX driver calls on Asus ROG motherboards This option can only be used when the Asus Al Suite is installed Dell SMI sensor support With this option we can control whether AIDA64 uses low level features to measure temperatures and cooling fan speeds via Dell SMI sensors In rare cases polling the Dell SMI sensor device may cause system slowdowns or lockup HID UPS sensor support With this option we can control whether AIDA64 uses low level features to monitor battery power and voltages via HID UPS sensors In rare cases polling HID UPS sensors may cause system slowdown Koolance TMS 200 sensor support With this option we can control whether AIDA64 uses low level featu
55. C WD10EZRX 00DC0B0 WD WMC301210 WDC WD10EZRxX 00DC0B0 WD WMC301213 WDC WDS50004AAD5 0059B0 519HNEAD3011 10 0 9200 16798 08 00 27 00 08 D6 G5 g Kingston DataTraveler 2 0 USB Device 7 GB USB Mass Storage Device i 117 events Value After Google Chrome 33 0 1750 134 Remote Desktop Keyboard Device Remote Desktop Mouse Device Generic Flash H CF USB Device Generic Flash H5 COMBO USB Device Samsung 55D 240 Series 519HMNEAD301172 WDC WDIOEZRX 00DCOBO WD WMC301210 WDC WDI0EZRX 00DCOBO WD WMC301213 10 0 9200 16843 Kingston DataTraveler 2 0 USB Device 7 GB D4 3D 7E 38 25 B0 USB Mass Storage Device We need to load at least two or more reports in Change Manager in order to view the changes which can be displayed in seven tabs Computer User Date Date Time Event Component Full list By clicking the Start button we can load reports from our database configured in the Preferences menu 13 AIDA64 Business File menu On the General tab in Change Manager Preferences we can define if we want to load the reports from a database General Filter Components Exceptions or from a folder containing CSV report files When General Load reports from performing network audit it is recommended to save Y ona reports in CSV format because these can also be O Folder CSV report files imported into a database later if needed Using Report ee y Use file name instead of comp
56. DA64 Report Wizard can be started by clicking on the Report button on the toolbar or by Welcome to the Report Wizard selecting Report Wizard in the Report menu This wizard will help you to create a report of your computer r Aft leting this wizard int th i Report Wizard follows the standard Windows eee ee you choose to include in the report to avoid generating huge wizard layout The first page is a welcome page ta then on the second page we can select the report profile we want to use A report profile is no more than a list of those pages from the Page menu which will be included in the report AIDA64 offers some predefined report profiles to let users quickly create standard report files but it also allows us to create a custom report profile by selecting the pages we want to see in the report or loading a previously created custom profile Cancel These settings can be automated using command line options Using the switches R E or FTP we can create full reports We can also use custom reports if we add any of the following options after R E or FTP SUM HW SW BENCH AUDIT or CUSTOM lt path gt 64 AIDA64 Business Report 5 1 1 REPORT PROFILES All pages This report profile includes all available pages Report profiles from the Page menu from Computer Summary to Database ODBC Data Sources Although this EA profile offers the most information it should be Kiii used with care as the resulti
57. DA64 is capable of displaying hardware monitoring data on LCD equipped Logitech keyboards as well as some Razer laptops and keyboards Supported Logitech keyboards include the Logitech G15 Gaming Keyboard and the Logitech G19 Gaming Keyboard Due to lack of programming tools and SDK the Logitech Cordless Desktop MX 5000 Laser keyboard is not supported by AIDA64 AIDA64 also supports Razer laptops and keyboards equipped with SwitchBlade LCD Such products include the Razer Blade Pro Gaming Laptop the Razer DeathStalker Ultimate Gaming Keyboard and the Razer SWTOR Star Wars The Old Republic Gaming Keyboard Here we can also set the background color for keyboards with a color LCD display e g Logitech G19 Gaming Keyboard El Preferences AIDA64 2 Search LCD Language iy General 13 Layout E Stability Y Report A Matrix Orbital LK Matrix Orbital GLK Matrix Orbital GX Abacom AlphaCool Enable Logitech LCD support LCD background color Digital Devices LCD2USB Colors Razer SDC Megtron Logitech Mad Catz F E mail Database jE Summary i Custom Variables Y Content Filtering g Custom Components 5 Asset Profile AE Remote Features Y Custom Programs y File Scanner A Network Alerting E Hardware Monitoring API LgLcdApi Interface USB h Basic E a a Ss B TT eee BEEEED TILE EENET TENTENE 22 Update Frequency Sensor Icons E OSD Y Desktop Gadget amp LCD
58. DAG4 Stable 4 00 2700 old NetUpdate is finished AIDA64 is up to date lt lt I 4 k x ABOUT The AIDA64 about page displays information about the purchase date the license expiry date and the number of computers on which we can use AIDA64 Business as well as a link to the official website where we can renew the license AIDA64 Business Product Information Product AIDA Business Version 4 30 3000 Build date 2014 05 27 Check for Updates License Information Purchase date 2014 01 20 License count 29 License expiry 2017 01 22 Maintenance expiry 2017 01 22 Copyright c 1995 2014 FinalWire Ltd All rights reserved worldwide 92 AIDA64 Business Page menu In the AIDA64 Page menu individual hardware and software components as well as some other items are listed in a user friendly simple tree structure The main categories are expandable and collapsible COMPUTER Summary The Summary page lists the main hardware and software components of the given PC We can select the individual items we would like to see here and add custom variables to the page in Preferences Summary We can also add custom components to the Summary page in Preferences Custom components and custom variables in Preferences Summary 64 File View Report Remote Favorites Tools Help HD CERE Zion Menu Favorites Field Value ES AIDA64 Computer 47 Computer Computer Type ACPI x64 based PC E
59. DBC can be downloaded from http pgfoundry org projects psalodbc 3 7 9 SYBASE SYBASEASEOLEDBPROVIDER If we use a Sybase database we can specify a data source although this is not required We need to specify the server name or IP address and the port required for the database connection then select the database We can also add a user name password combination or choose Windows authentication If want to save reports to a Sybase database it is necessary to install the Sybase ASE ODBC driver on all networked computers lt can be found on the Sybase installation CD SUMMARY Each line of the Computer Summary page can be either shown or hidden by pro checking or unchecking the check My Mi computer Mi Computer Type boxes in this list The software uses these settings for creating reports too so here we can select the components we would like to see in the reports when we create reports using the System summary only option in Report Wizard or the SUM command Es Report _ Report File D Report Look 1 Remarks a E mail ely SMTP Database Custom Variables Content Filtering m Ey Custom Components oe Asset Profile ix Operating System fm OS Service Pack E Internet Explorer DirectX E Computer Name E User Name 5 SMTP E mail Address E Logon Domain Date Time gt Motherboard A cru Type gt Motherboard Name ME Motherboard Chipset m System Memory
60. DH AIDAG4 AIDA64 Business User manual v1 2 30 07 2014 AIDA64 Business is developed by FinalWire Ltd Copyright 1995 2014 FinalWire Kft This document was created by ABSEIRA Ltd All rights reserved Copyright 2010 2014 ABSEIRA Kft The names of actual companies and products mentioned herein may be the trademarks of their respective owners AIDA64 Business Contents CONTENTS 1 INTOQUCUON rareza tecnica erica earlier o ciaicas 7 1 1 SYSISEM FEQUIFEMEMS a ococcononniananania cnn dencia 7 Bz WISE TIPO suscrita 8 2 PNG EGTA nnn aE AA sidsuiasedsnueace cick weemsaciauetedecsuensesbacesssivceueassuaeeassexsewcaasdania 9 2 1 o e 9 2 2 Database WAAC A A 12 2 Change WAIN ACCU peta tects gacseeen esectaccct saa ehacacisciaa sna E E E 13 3 CIC GING CS essed cece oe NNA 16 3 1 A a 16 3 2 A A o EOS 17 3 2 1 etn ge catia AE E epee tig aes aoa ace ence T E eee 17 3 2 2 PPP e e 18 3 3 A E E S 19 3 4 AY o e E E E E E cates 21 3 5 DO oh ectsnsenaes sos geseateaigncstapececoeesecsaaes see assatecedetetaceceseveusiusstssunaneaeesncstapace deck A 24 3 5 1 e Pe PP 1 ES PU A rr SO O 27 3 5 2 RODO OOR IA PO O E O O 28 3 5 3 BS UN tas earner ccs gu nn o A e 28 3 5 4 e ooo o 30 3 0 5 Romak acco ett cents nea apm notice e A e 30 3 6 nn PP eee ee ea ee ee 31 3 6 1 AA 31 3 LD AA A e A o E OE O ESOO Ex 32 3 7 1 Borland InterBase Firebird MSDASGE issiersiseici atole peio lili 33 3 7 2 MS Access 97 MS Jet
61. E FF e UUIDMAC Inserts DMI System UUID When this is not available it inserts MAC address 00000000 00000000 0000AABB CCDDEEFF e MONTH Inserts current month MM e DATE Inserts current date YYYY MM DD e TIME Inserts current time HH MM SS File name This option specifies the file name to be used when the reports are saved to file For network audits either in the output folder name or the file name one of the variables listed above has to be used to prevent computers from overwriting the report files File extension This option specifies the file name extension to be appended to the report file name It is recommended that we keep the default automatic option This option does not modify the report format it specifies the file name extension only Search Report File Language Output folder SRVR2012 Shares AIDA64Business Reports DATE iy General ll Layout File name SHOSTNAME Gh Stability a E Report File extension Automatic D Report Look F Schedule de FTP io Remarks Always a E mail Za SMTP EN Database ill Summary g Custom Variables Y Content Filtering y Custom Components 55 Asset Profile HE Remote Features S Remote Control Security Y Custom Programs J File Scanner Network Alerting E Hardware Monitoring Cancel 27 AIDA64 Business Preferences 3 5 2 REPORT LOOK This page allows us to customize the look of the reports We
62. L module relies on the OpenCL compiler which optimizes the OpenCL kernel to run best on the underlying hardware The OpenCL kernels used for these benchmarks are compiled in real time using the GPU s OpenCL driver Because of this it is always recommended to have all video drivers Catalyst ForceWare HD Graphics etc updated to their latest version For the compilation the following OpenCL compiler options are passed cl fast relaxed math cl mad enable For comparison purposes the GPGPU Benchmark Panel offers CPU measurements as well However the CPU benchmarks do not use OpenCL but are written in native x86 x64 machine code utilizing available instruction set extensions such as SSE AVX AVX2 FMA and XOP These CPU benchmarks are very similar to the old AIDA64 CPU and FPU benchmarks but this time they measure maximum computing performance FLOPS IOPS The CPU benchmarks are heavily multi threaded and are optimized for each CPU architecture introduced since the first Pentium AIDAG4 GPGPU Benchmark i ES j GPU Intel R HD Graphics 2500 IVB DT GT1 350 MHz 24 cores 6 CUs Driver 10 18 10 3412 CPU Intel Core i5 3450 Ivy Bridge DT 3017 MHz 4 cores 4 threads GPU x64 CPU Memory Read 4493MB s 18091MB s_ 7 2a Se et ARA me Memory Write 5247 MB s 18047 MB s Memory Copy Single Precision FLOPS 42 62GFLOPS 190 2GFLOPS Double Precision FLOPS Not Supported 94 96 GFLOPS 24 bi
63. MTP E EN Database 1 Summary ay Custom Variables Y Content Filtering E Custom Components ke Asset Profile a Remote Features S Remote Control El Custom Programs a P File Scanner P File Scanner Filter e File Properties A Network Alerting oi Alert Methods yN Alert Triggers b E Hardware Monitoring 44 Security a All incoming connections are accepted Connections are accepted only from the following jE OFFICE101 pl OFFICE103 8 Connections are accepted only from the following computers New Modify Delete users o Administrator O Connections are accepted only from the following EP 192 168 1 103 EY 192 168 1 101 192 168 1 102 New Modify Delete IP addresses New Modify Delete AIDA64 Business Preferences CUSTOM PROGRAMS Here we can add any programs and files to the Software Custom Programs page in the Page menu the availability of which we would like to monitor We need to specify the file size in bytes E Preferences AIDA64 O Search Custom Programs weed E Layout 3 Stability a Report Description Folder File Name File Size Report File ven D Report Look 0 Schedule PP i Remarks E Ka _ Check if a specified file in a specified folder exists 0 Check if a specified folder exists 8 Scan a folder to find a
64. Menu Favorites EZ AIDA64 v4 50 3000 b ql Computer gt Motherboard gt L Operating System p 3 Server gt i Display gt a Multimedia 3 Storage gt EY Network s P DirectX ol DirectX Files G2 DirectX Sound gt El Devices gt E Software D M Security gt EH Config gt E Database D 3 Benchmark DirectX Video DirectX Sound DirectDraw Driver Description Primary Display Driver Field DirectDraw Device Properties DirectDraw Driver Name DirectDraw Driver Description El Hardware Driver E Hardware Description Direct3D Device Properties e Rendering Bit Depths Z Buffer Bit Depths Multisample Anti Aliasing Modes Min Texture Size Max Texture Size Unified Shader Version DirectX Hardware Support E Direct3D Device Features Value display Primary Display Driver igdumdim32 dll 10 18 10 3621 Intel R HD Graphics 16 32 16 24 32 MSAA 2x MSAA 4x MSAA 8x 1x1 8192 x 8192 5 0 DirectX v11 0 Ki Local This page provides DirectSound device information Double clicking any of the listed devices will run the DirectX Diagnostics tool DirectX Input This page provides DirectInput device information such as mouse and keyboard properties 103 AIDA64 Business DEVICES Windows Devices Page menu This page displays the same information as the Device Manager in Windows But AIDA64 is capable of rec
65. Most GPUs do not have dedicated execution resources for 64 bit integer operations Such devices emulate 64 bit integer operations on their 32 bit integer execution units In such cases 64 bit integer performance can be very low AES 256 we can use this OpenCL based GPGPU benchmark to measure the AES 256 encryption performance of modern graphics processors and APUs SHA 1 we can use this OpenCL based GPGPU benchmark to measure the SHA 1 hashing performance of modern graphics processors and APUs Single Precision Julia Measures single precision 32 bit float floating point performance through the computation of several frames of the popular Julia fractal Double Precision Mandel Measures double precision 64 bit double floating point performance through the computation of several frames of the popular Mandelbrot fractal Not all GPUs support double precision floating point operations For example current Intel desktop and mobile graphics devices only support single precision floating point operations 78 AIDA64 Business Tools 8 3 1 THE GPGPU BENCHMARK PANEL S USER INTERFACE You can use the checkboxes to select a GPU device or the CPU for the benchmarks The state of the CPU checkbox will be stored after closing the panel You can launch the benchmarks for the selected devices by clicking the Start Benchmark button If you want to run all benchmarks but only on the GPU s you need to doubl
66. O Albanian O Arabic O Belarusian O Bosnian O Bulgarian O Catalan O Croatian O Czech O Danish Dutch Estonian English Finnish French German Hungarian Indonesian O Italian O Japanese O Korean O Latvian Shqipe lerd er Bosanski Au afdne Catalr Hrvatski Cesky Dansk Nederlands Eesti English Suomi Francais Deutsch Magyar Bahasa Indonesia Italiano CNeali Latviesu 16 AIDA64 Business Preferences GENERAL On the General tab we can find the general AIDA64 settings for example we can define how the software starts or how often it looks for software updates General a ES _ Display AIDA64 in the Control Panel Search _ Load AIDA64 at Windows startup Y Display AIDA64 splash screen at startup 4 5 Report Y Minimize button minimizes main window to System Tray 7 Report File 09 Report Look nf Schedule Icons style Windows 7 v ED Remarks When AIDA64 starts Y Close button minimizes main window to System Tray 4 D E mail Display main window i 183 SMTP EF Database Hide main window minimize to Taskbar Hide main window minimize to System Tray Y Custom Variables Y Content Filtering NetUpdate g Custom Components dep Check for updates Once a day ge Asset Profile gt AE Remote Features Update type Stable updates only A Custom Programs _ Save update packages to local folder b p File Scanner
67. Pe N E my 1 4 HUN a li k S BOP i 4 11 07 2014 91 AIDA64 Business Preferences 3 17 3 OSD Here we can customize the AIDA64 OSD panel which displays the user selected sensor items in a window on the Windows desktop Show OSD panel Here we can enable or disable the OSD panel Display icons on OSD panel Both text and icons are displayed in the OSD panel when this option is enabled Otherwise only the text displaying the sensor readings is visible Display labels on OSD panel Labels are displayed on the OSD panel when this option is enabled Align items to the right ltems are aligned to the right on the OSD panel when this option is enabled Otherwise the items are aligned to the left Keep OSD the topmost window When this option is enabled the OSD panel is always visible on top of all other windows This feature is also called always on top OSD panel background color Here we can customize the background color for the OSD panel Background color should be selected to ensure proper text readability OSD panel transparency Here we can set the transparency level of the OSD panel Window transparency level adjustment is not supported under Windows 95 98 Me and NT 4 0 92 AIDA64 Business 3 17 3 1 OSD items Preferences Here we can select the items we want to display on the OSD panel Double clicking or selecting an item will display the settings window for the item where we can customize
68. Search Server 86 101 168 7 FIP port 21 Default User si Report ve Report File Password E iD Report Look nO Schedule AS FTP folder CSV files i ri _ Use Passive Mode io LID Remarks at E mail 4 y SMTP EY Database wef jE Summary E Custom Variables Y Content Filtering ll Custom Components 55 Asset Profile a E Remote Features S Remote Control be a Security fii Custom Programs b p File Scanner p Network Alerting b O Hardware Monitoring Cancel Apply 3 5 5 REMARKS We can add remarks to the reports These remarks will appear on the top of the reports If we write ALL in the computer name field or press the All button the remarks will appear in the reports of every computer If we add computers individually only the reports of the listed computers will contain the remarks For example we can indicate in the reports why we needed to create them jE Computer Name ALL D Remark 30 AIDA64 Business Preferences E MAIL If we want to receive e mail notifications of any alert events we need to configure the e mail settings Here we can specify the e mail address to which we would like AIDA64 to send the reports To Cc and Bcc addresses If we save our reports to a TXT file and we enable the option Embed TXT reports to e mail body the report content will be part of the message body and will not be attached The
69. U E Control Panel Country Code 36 E Recycle Bin d System Files SH Currency Le System Folders ES Currency Name Native forint Ja Event Logs EH Currency Name English Hungarian Forint gt 2 Database E Currency Symbol Native Ft gt 1 Benchmark ES Currency Symbol ISO 4217 HUF v Regional JE Local Copyright c 1995 2014 FinalWire Ltd Environment This page enumerates the environment variables available in Windows These can be used between signs in scripts or command line commands Control Panel This page lists those programs and services which are represented with an icon in the Control Panel Double clicking them will open their settings page Recycle Bin This page lists the recycle bins for each partition We can empty recycle bins directly by double clicking them System Files This page lists the system files and their content System Folders This page lists those folders which are created during Windows installation for example Program Files Users or AppData Double clicking them will open the folders in a new window Event Logs This page displays the Windows event log Double clicking on any item will open their event properties 107 AIDA64 Business DATABASE These pages provide information about the installed database software such as database servers and driver versions Further details about the drivers specifically ODBC and BDE drivers are found in the corresponding
70. UID When this is not available it inserts MAC address 00000000 00000000 0O000AABB CCDDEEFF e MONTH Inserts current month MM e DATE Inserts current date YYYY MM DD e TIME Inserts current time HH MM SS The default environment variables of Windows can also be used these are listed in AIDA64 on the Config Environment page If we want to use these we need to enclose them in percent signs for example LOGONSERVER ENTERING PRODUCT KEY LICENSE INFORMATION When launching AIDA64 Business for the first time we have to enter the product key which was provided in the product registration email after purchase The software can be activated without A Please enter your product key A NA Online Documentation Cancel 9 7 1 LOST PRODUCT REGISTRATION KEY If we cannot find our product registration key we need to send an e mail to support abseira com and provide the following information e Company if applicable e Fullname e E mail address e Purchased product e Approx date of purchase 91 AIDA64 Business Help CHECK FOR UPDATES By clicking on this menu item we can start a check for updates at any time Otherwise AIDA64 can be configured to automatically checks for updates on a regular basis x ey Checking for updates Ey Connecting to the Internet ey Starting Internet download session Y Connecting to NetUpdate server E Downloading NetUpdate information Ej Available updates E AI
71. Unknown 39h MC 02h LGA1155 12h 0 4 105 C 221 F TIW Unlimited 50A Unlimited Power 8 00 sec 77 W 1 00 sec Locked 96 W Unlimited Time Locked 1C 35x 2C 35x 3C 34x 4C 33x Supported Not Supported Not Supported Not Supported Not Supported Disconnect Copyright c 1995 2014 FinalWire Ltd AIDAB4 Es Operating System Microsoft Windows 8 1 Professional peter godi Mil Computer Name IRODA102 GP 10 30 19 11 2013 Om i 4 HUN AIDA64 Business Remote features REMOTE CONTROL This menu item can be used to start a graphical remote control session which allows us to take full control of the remote computer and send receive files We can select the remote computer by specifying an IP address or a computer name 2 lt File Remote Shortcuts View Tools NET Usage 27 54 MB 6215 bytes s Server Resolution 800 x 600 64 File View Report Remote Favorites Tools Help gt es 8 m Y Report Menu Favorites b JE Computer gt E Motherboard D Y Operating System gt 3 Server gt AL Display gt lj Multimedia gt Storage D 4 Network gt 3 DirectX gt Devices gt El Software gt M Security gt ES Config D Database gt 73 Benchmark Page Computer Motherboard Po Operating System 5 Server amp Display a Multimedia e Storage X Network E Directx y Devices El Software Security
72. allowed Address Os UpTime Idle Time CPU Disk Total lt Remote Monitor gt iL Remote Computers i Remote System Information In the screen shot we can see that connection has not been established with the remote computer To establish a connection we need to right click on a blank area in the window to activate the context menu go to Remote Monitor then select Remote Computers Copy All Here we can select one or more computers using an IP address or computer name If we have more networks in use we can select the name of the network or specify Lo O Connect to single computer an IP address range Address OFFICE101 OFFICE101 LT _ LA 8 Scan local network for computers Network LAN1 192 168 1 117 v 192 1168 1 1 1192 168 1 254 Cancel After pressing OK we will see the IP addresses of those PCs listed in the Pending tab to which AIDA64 is trying to connect Those client computers to which connection was successfully established will be listed in the Connected tab Should there be any remote PCs to which somebody else has already connected the IP address of these will appear in the Busy tab while those computers to which AIDA64 could not connect are listed in the Error tab In the Disconnected tab we can see the IP address of those computers to which we have already connected 69 AIDA64 Business Remote features On the client computers a bubble above the notificati
73. ams such as version number and virus database date Firewall This page provides information about any installed firewall programs such as version number and status Anti Spyware This page provides information about any installed anti spyware programs Anti Trojan This page provides information about any installed anti trojan programs 106 AIDA64 Business Page menu CONFIG Regional This page provides an overview of the regional settings in Windows Date and time zone Language Region Date format etc Double clicking on any item will open the Region and language settings window 64 File View Report Remote Favorites Tools Help Ed UEM y neon Menu Favorites Field Value EZ AIDA64 3 Time Zone gt ME Computer Current Time Zone Koz p eur pai ny ri id gt gt Motherboard 6 Current Time Zone Description UTC 01 00 Budapest Belgr d Ljubljana Pozsony Praga gt MY Operating System 1 Change To Standard Time Last Sunday of October 3 00 00 J Server Change To Daylight Saving Time Last Sunday of March 2 00 00 A Display gt a Multimedia gt Storage EY Network gt GP DirectX gt El Devices H ra E Country Region a A Config cn Country Name Native Magyarorsz g e Country Name English Hungary a Language o Language Name Native magyar a Language Name English Hungarian Language Name ISO 639 hu i af Environment Country Name ISO 3166 H
74. an configure the interval between disk temperature measurements Setting this option to less than 20 seconds may result in data corruption on older hard disk drives For modern HDDs and SSDs it is safe to enter any value of our choice Decimal digits for voltage values With this option we can set the number of decimal digits to be displayed for voltage readings For modern computers selecting at least 3 digits is recommended 50 AIDA64 Business Preferences Decimal digits for clock speeds With this option we can set the number of decimal digits to be displayed for clock speeds e g CPU core clock FSB clock and memory clock Tjmax temperature With this option we can set the Tjmax temperature that is used to calculate core temperature readings for Intel processors When Automatic is selected AIDA64 will use the default values as defined in the Intel Digital Thermal Sensors DTS specifications Degree symbol With this option we can configure the character to be used as a degree symbol for temperature readings 3 17 1 UPDATE FREQUENCY Here we can set the update frequency for the Computer Sensor page the Display GPU page the Sensor Icons the OSD panel the Desktop Gadget the Logitech LCD the SensorPanel and the external applications function and configure the logging interval for the hardware monitoring logs and the alerting function When using T Balancer miniNG or bigNG devices it is strongly recommended
75. and settings used in the panel so we can use it to share our SensorPanel with friends who can start using it by pressing the Import button 3 17 7 LOGGING With AIDA64 we can save sensor readings to a log file Sensor values are saved either to an HTML or CSV file and logging intervals can be set on the Preferences Hardware Monitoring Update frequency page in seconds We can choose to log when processes start or stop and specify the number of hours between 1 and 72 hours after which we want to open a new log file The items we want to include in the log can be selected using the checkboxes in the list Search gt ES i gt 437 Report gt F E mail Database JE Summary Y Custom Variables Y Content Filtering gl Custom Components 5 Asset Profile gt AE Remote Features fii Custom Programs gt gt File Scanner gt A Network Alerting a amp Hardware Monitoring E Sensor Icons gt E OSD gt E Desktop Gadget gt Mi LCD Q SensorPanel i g Logging Log sensor readings to HTML log file SRVR2012 Shares AIDA64Business log SHOSTNAME _ Log sensor readings to CSV log file Log started and stopped processes Number of hours between opening new log files 24 kd jE System A O 16 UpTime LJ n CPU Clock OA CPU Multiplier OA cru Fsg _ m Memory Clock C Z CPU utilization Y 3 CPU Utilization O amp CPUZ2 utiliza
76. arch File Scanner Q Language P Scan scope y General Layout Qh Stability Scan all local disks Report Scan system drive _ Report File a D Report Look Scan C drive 1D Schedule Scan ProgramFiles folder No file scanning aa de FTP O Scan ProgramFiles and Windows folder 1D Remarks 4 7 E mail 8 Selected folders Za SMTP Le SRVR2012 Shares AIDA64Business Szil Database fll Summary Y Custom Variables Content Filtering a Custom Components BE Asset Profile gt AE Remote Features Custom Programs 4 beJ File Scanner Filter pP File Properties b Network Alerting b 8 Hardware Monitoring OK Cancel Apply Delete On the File Scanner Filter page we can choose extension based filtering options e All files e Executable files e DLL files e Audio files e Video files e Misc files where other file extensions can be listed separated by commas Search File Scanner Filter ro Language pP Filter by file name D General Al files Executable files com exe DLL files dll E Report File _ Report Look _ Audio files mp3 ogg ra wav wma D _ Video files asf avi divx mov mpeg mpg rm wmv _ Misc files mp3 Filter by file size gif Custom Variables it Y Content Filtering Files smaller than Custom Components Files l
77. arch engine will list those pages the title or contents of which contain the search term Network Alerting E Stability a A Network Alerting A Alert Methods E Alert Triggers 0 Update Frequency fi Alerting A Number of minutes between checking for alerts Number of hours between sending repetitive alerts Store system configuration details in 8 TEMP folder of the logged on user Root folder of the system drive O Custom folder LANGUAGE The first page of the Preferences window lists all available user interface languages The user interface language can be changed by selecting the desired language from the list and then pressing the OK button However to ensure that all user interface elements are updated and displayed correctly it is recommended to restart AIDA64 after changing the user interface language AIDA64 currently supports more than 35 languages but certain modules for example the CPUID panel the memory benchmarks monitor diagnostics and remote control are only available in English Search Language Gh Stability a 7 Report __ Report File 3 3 Database Mi Summary el Custom Variables Y Content Filtering y Custom Components ke Asset Profile D ME Remote Features Al Custom Programs gt gt File Scanner a A Network Alerting A Alert Methods Ay Alert Triggers D Q Hardware Monitoring
78. arger than y Asset Profile gt My Remote Features fi Custom Programs di P File Scanner ba JO File Properties b Network Alerting b Q Hardware Monitoring 1000 KB 46 AIDA64 Business Preferences On this page we can also choose file size based filtering e All files e Files smaller than the specified size e Files larger than the specified size On the File Properties page we can select the file properties we want to see on the Software File Scanner page for each file Search File Properties pP File properties logged by the File Scanner Folder File Name a 5 Report File Size bel Report File a L ID Report Look reation Time E Last Modification Time Last Access Time CompanyName FileDescription Ed Database FileVersion JE Summary Ef Custom Variables InternalName Y Content Filtering LegalCopyright Ey Custom Components OriginalFilename 55 Asset Profile b Remote Features ProductName fay Custom Programs ProductVersion 4 gt File Scanner gt File Scanner Filter D Network Alerting D EY Hardware Monitoring Cancel Apply NETWORK ALERTING The network alerting function can greatly facilitate the everyday job of system administrators AIDA64 can send alert notifications if hardware or software changes occur or when issues problems arise For example we can ask for notifications if a user who might not be authorized to do so installs new so
79. atabase A CPU Sockets Slots 1 LGA1155 gt E Benchmark Expansion Slots 1 PCI 1 PCI Ex1 1 PCI E x16 v Motherboard Local Copyright c 1995 2014 Fin 94 AIDA64 Business Page menu Memory This page provides memory information including physical and virtual memory swap file size and Physical Address Extension PAE The page is updated dynamically which makes it possible for us to check memory utilization and free memory in real time SPD This page provides information about the installed memory modules including clock speed timings voltages We can get detailed information about each installed module by selecting the appropriate DIMM slot At the bottom of the page information about XMP EPP and AMP memory profiles is also provided Chipset This page provides information about the motherboard chipset north and south bridge including memory timings installed memory modules supported memory types and integrated graphics and audio controllers BIOS This page displays system and video BIOS information Asus ATK and Intel XTU are used to provide current BIOS settings ACPI This page displays the Advanced Configuration and Power Interface ACPI table properties On the SLIC table we can see information about the Windows license while at the bottom of the DSDT table we can check NVIDIA SLI and Lucid Virtu certifications 95 AIDA64 Business OPERATING SYSTEM Operating system Page menu Th
80. atency o Casosomejs 16044 mej 16357m87 vere eae 37177 GB s 187056B s 35684GB s 15m L2 Cache 159 31 GB s 107 46GB s 140 91 GB s L3 Cache 132 57GB s 109 70GB s 114 99GB s ea u S E IC o CA Rd o en 7 Ss PAS a CPU Type QuadCore Intel Core i5 3450 Ivy Bridge DT LGA1155 CPU Stepping E1 L1 NO PO CPU Clock 3013 6 MHz original 3100 MHz CPU FSB 97 2 MHz original 100 MHz CPU Multiplier 31x North Bridge Clock 3013 6 MHz Memory Bus 648 1 MHz DRAM FSB Ratio EE Memory Type Dual Channel DDR3 1300 SDRAM 9 9 9 24 CR1 Chipset Intel Panther Point B75 Intel Ivy Bridge Motherboard MSI B75MA P45 MS 7798 Start Benchmark 76 AIDA64 Business Tools GPGPU BENCHMARK This benchmark panel which can be launched from Tools GPGPU Benchmark offers a set of OpenCL GPGPU benchmarks These are designed to measure GPGPU computing performance using various OpenCL workloads Each individual benchmark can be run on up to 16 GPUs including AMD Intel and NVIDIA GPUs or the combination of these Of course CrossFire and SLI configurations as well as both d PUs and APUs are fully supported Currently there is only preliminary support for HSA configurations Basically any computing device that is listed as a GPU among the OpenCL devices will be benchmarked Current OpenCL benchmarks are not optimized for any GPU architecture Instead the AIDA64 OpenC
81. can a folder to find a file can be used to check the existence of a file in a specific folder and its subfolders using file scanning We can optionally specify the file size in bytes For example to detect Oracle R8 1 installation it is possible to check for the existence of the file called oraclient8 dll in the folder c oracle and its subfolders using file scanning AIDA64 offers a couple of variables which can be used in folder names e SYSTEMDRIVE Inserts the letter of the system drive Example SYSTEMDRIVE oracle e PROGRAMFILES Inserts the path of the ProgramFiles folder Example PROGRAMFILES FinalWire AIDA64 e WINDOWSDIR Inserts the path of the Windows folder Example WINDOWSDIR ServicePackFiles e SYSTEMDIR Inserts the path of the Windows system folder Example 5SYSTEMDIR drivers e ALLDRIVES Inserts all local disk drive letters one after the other to provide the ability of scanning all drives for a specific folder when it is not known which local disk partition a program is installed on Example ALLDRIVES oracle 45 AIDA64 Business Preferences FILE SCANNER We can select the scope of the file scanning process from a list of predefined paths or by adding the folders we want to scan The available options are e No file scanning e Scan all local disks e Scan system drive e Scan C drive e Scan ProgramFiles folder e Scan ProgramFiles and Windows folder e Selected folders Se
82. can select fonts font size and color we can apply styles bold italic and change the background color of the reports These settings are applicable for HTML and MHTML reports only Search Report Look Language Normal Font Page Caption Font Device Caption Font g y General ll Layout AGE Stability 4 7 Report ba Report File E Repor Loo a E Schedule Colors Colors Colors NE a i Remarks Bold Bold Bold s C italic C italic C Italic Name Verdana w Verdana v Verdana v Size 3 Database Background color Y Custom Variables Y Content Filtering 4 Custom Components ke Asset Profile Restore Default Values a ME Remote Features S Remote Control 2 i Security fey Custom Programs File Scanner gt A Network Alerting gt E Hardware Monitoring Cancel 3 5 3 SCHEDULE Using command line options we can set how often we want AIDA64 to create reports and specify the location of the data required for scheduling The options on this page apply only for the command line options R E and FTPUPLOAD Colors Command line options are limited to make report Here we can specify the frequency of report creation Available options are e Anytime AIDA64 creates a new report every time it is launched For network audits when the report creation is issued from a central logon script a new report is created on each user logon For example if a user logs on to his
83. ce Report Server SRVR2012 4 i E Report File Server port 3306 D Report Look rO Schedule Database AIDAG4 a Driver MySQL ODBC 5 2 Unicode Driver i Remarks a 7 E mail User AIDA64 i 06 6 gg SMTP Password eer Database _ Use Windows authentication w Custom Variables _ Use automatic identity increment Y Content Filtering y Custom Components olf Asset Profile a Ma Remote Features S Remote Control b p File Scanner gt A Network Alerting E Hardware Monitoring Cancel Apply 3 7 7 ORACLE MSDAORA If we use an Oracle database we need to specify the server name or IP address and the port required for the database connection then select the database We can also add a user name password combination or choose Windows authentication If we want to insert reports to an Oracle database it is necessary to install the Oracle Client on all networked computers lt can be found on the Oracle installation CD 39 AIDA64 Business Preferences 3 7 8 POSTGRESQL MSDASQL If we use a PostgreSQL database we can specify a data source although this is not required We need to specify the server name or IP address and the port required for the database connection then select the database and the driver We can also add a user name password combination or choose Windows authentication When PostgreSQL is selected it is necessary to install PsqKODBC on all networked computers PsqlO
84. ce and volume serial 100 AIDA64 Business Page menu Physical Drives This page lists the disk drives which use MBR or GPT partition tables Partitions are also listed for the selected drives Optical Drives This page provides information about the optical drives CD DVD and Blu ray drives including virtual drives For most drives supported media formats as well as read and write speeds are also indicated Links to the manufacturers firmware download websites are provided at the bottom of the page ASPI This page provides information about the Advanced SCSI Programming Interface drives ATA This page provides detailed information about the IDE and SATA hard drives and SSDs Beside the ATA auto detect data disk drive and SSD physical properties form factor RPM flash memory and SSD controller type are also provided SMART This page displays SMART Self Monitoring Analysis and Reporting Technology attribute status information We can configure AIDA64 to send alerts if errors occur Alert triggers can be selected in Preferences Alert triggers 64 File View Report Remote Favorites Tools Help SDC SRM Fieve Menu Favorites Device Description E AIDA64 ca KINGSTON H1038390G 50026B7226004AD9 gt 1 Computer e WDC WD10EZRX 00L4HB0 WD WCC4J2602142 Motherboard 3 Pa ID Attribute Description Threshold Value Worst Data Status z erver q A Display 01 Raw Read Error Rate 51 200 200 0 OK Value is
85. computer 5 times a day AIDA64 will create 5 reports of his computer each day e Once a day AIDA64 creates only one report per day regardless of the number of times it is launched For network audits AIDA64 will create a report of each computer only on the first user logon and on any further logons it will simply quit without running the report creation process e Once a week AIDA64 creates only one report per week regardless of the number of times it is launched e Once a fortnight AIDA64 creates only one report every fortnight 2 weeks regardless of the number of times it is launched e Once a month AIDA64 creates only one report per month regardless of the number of times it is launched 28 AIDA64 Business Preferences Schedule tag storage This option specifies the location where the last report creation date will be stored We have to select the option that is best for our network audit requirements Registry Machine Last run date will be stored in a common user independent location in the Windows Registry This option is useful for network audits when reports should be created per computer and not per user For example when Once a day schedule limit is specified and a computer is used by 3 different users the report will be created only on the first user logon This way only one report will be created per day for the given computer regardless of the number of times the 3
86. configure fan divisors so AIDA64 can be used simultaneously with these only if this option is disabled Low level SMART operations With this option we can control whether AIDA64 uses low level SMART disk calls that may cause system lockup in rare cases When this option is disabled no hard disk temperature and SMART disk health status information will be provided RAID member enumeration With this option we can enable or disable low level RAID member enumeration calls for RAID arrays that may cause system lockup in rare cases When this option is disabled no ATA autodetect information or SMART disk health status information can be provided for RAID arrays RAID SMART support With this option we can control whether AIDA64 uses low level SMART disk calls for RAID arrays that may Cause system lockup in rare cases When this option is disabled no hard disk temperature and SMART disk health status information will be provided for RAID arrays nVIDIA GPU SMBus access through NVGPIO This option can be used to improve the stability of GPU sensor readout on Asus graphics cards with Asus SmartDoctor installed and running Change to 3D profile on nVIDIA video adapters When this option is enabled the GPU detection module of AIDA64 will switch to 3D profile This way the software can measure the maximum clock speed of the GPU However when the video adapter switches to 3D profile the GPU fan speed may also increase SMBus access through
87. coonccnnccononccnncnonancnnnonnnancnncnnnnancnncnnnnns 79 8 4 AGRIEBFOWS O aaa ra a ooepbid 80 8 5 DRAM TMS nenea a a do A 80 8 6 Monitor DINOS ES id 81 8 7 System SID Tests a 83 8 8 AIDA CUIDA E 83 A dba aia 84 9 1 AIDACA lo o A eo Eo A PP nn oe eee ee ee ee ee eee 84 AIDA64 Business Contents 9 2 ADA e le katate hte 84 9 3 A TOU ain states tls aed viainns ull dae tee ess ie basae dean eee aay tesa tease enema aoe 85 9 4 COMA Sait acto O tea dete Gaahiduis oat parmeseestmsba E E 85 9 5 e nn e e 86 9 6 COMIMANGHIINE ODUOINS iia io awa 86 9 6 1 A aaa 2 asnaue dud ss ccdulmenaduvhnnt Clsmauenhayetoc Muemmuads 87 9 6 2 FICTIONS FED e q IRA OP A My siuessdancaendsnearaaie 88 9 6 3 FICDON CON VEIA inaa yan sis 88 9 6 4 REDO Prol a a ne 88 9 6 5 A o A A A 89 9 6 6 Remoto CONNCCUON asiatica 89 9 6 7 A DE Se E E A A E E E ig hasan A E snetcola duane E T 90 9 6 8 TFOWDIE SADO de 90 9 6 9 Miscellaneous ia oo ica 90 9 6 10 O A ea teats ee bose aerate tte 91 9 7 Entering Product Key License Informati0N ccocooocnnnccnnncccccononnncnnnnconononanccnnnnnononnnnnncnnnnnnnnnnnnns 91 9 7 1 Lost produ uctregistaton CY eects aetna ad ec tye lala ce het ahd elaine a idl aa eae 91 9 8 GC CK AOR Ue a a toi o 92 9 9 ADOUR borin d ae eastaa tea uaa seoiadaatoninctea diac dna atees uaa ncoudou deus eos 92 10 Pag MENU raise eas hice ais 93 10 1 nn a meaaedeesa nance ieee dash tatsnc 93 10 2 Motherboard iaa ias 94 10 3 Ds a en eee ee eee 96
88. d Rate E RAS To RAS Delay E Write Recovery Time m Write To Read Delay m Read To Precharge Delay E Four Activate Window Delay m Write CAS Latency m Refresh Period m DIMMs Per Channel 80 AIDA64 Business Tools MONITOR DIAGNOSTICS AIDAG4 Monitor Diagnostics This menu item launches Monitor Diagnostics which can be used to check the capabilities and display performance of LCD and CRT displays This module uses 45 different test screens to help us detect possible Issues The tests are grouped under four main categories File Selection Help i Calibration Tests Grid Tests Color Tests Reading Tests e Calibration tests s A e Calibration Tests Focus Tests o Grid tests A Y LCD Calibration T White Pattern Black Pattern e Color tests e Reading tests Y Brightness Contrast v Scope Sharpness Y Y Dots Gamma Convergence Vertical Lines Y Y Screen Size Horizontal Lines MM By hovering the mouse pointer over any individual test we will be given hints as to the goal of the a test as well as what we need to pay attention to We can select which test or test groups we want Hint Auto Run Selected Tests Run Selected Tests On this page you can find several tests for monitor calibration These tests are suitable for both classic CRT and LCD to run this way we can focus on specific issues displays Move your cursor over a test
89. ded precision or 80 bit floating point performance through the computation of a single frame of a modified Julia fractal 109 AIDA64 Business Contact 11 CONTACT ABSEIRA Kft 1 E F 1 1 Erzsebet ter 2 1051 Budapest Hungary Registration number 01 09 947083 VAT identification number 22971074 2 41 E mail info abseira com Business hours from Monday to Friday between 8 00 and 16 00 CET ABSEIRA Lid is the international distributor of the AIDA64 product family v 1 0 First edition v 1 1 GPGPU Benchmark description added v 1 2 Description of new functions introduced in AIDA64 v4 60 added 110
90. ding Microsoft Windows and Office File Types This page lists the file types registered in Windows Desktop Gadget This page provides information about any Windows desktop gadgets which have been installed 105 AIDA64 Business Page menu SECURITY Windows Security This page provides basic operating system properties as well as User Account Control UAC and System Restore status information Supported Data Execution Prevention DEP technologies are also listed File View Report Remote Favorites Tools Help CDC ERM Jie Field Value E AIDA64 Ez Operating System Properties gt Ml Computer AT OS Name Microsoft Windows 8 1 Professional gt Motherboard y OS Service Pack ex p 3 Operating System Ez Winlogon Shell explorer exe p 3 Server ga User Account Control UAC Enabled Quiet Mode p y Display System Restore Enabled p a Multimedia b fa Storage p EP Network b GP DirectX b a Devices gt Software a E Security al Data Execution Prevention DEP NX EDE Ez Supported by Operating System E supported by CPU a Active To Protect Applications al Active To Protect Drivers 3 Anti Virus 8 Firewall b JE Config gt EF Database 13 Benchmark e Windows Security l Local Copyright c 1995 2014 FinalWire Ltd Windows Update This page enumerates the security updates and hotfixes installed on the operating system Anti Virus This page provides information about any installed anti virus progr
91. e Windows Server 2003 e Windows 8 Processor Intel Pentium or newer Memory 32 MB or more or 128 MB or more for running the benchmarks Available hard drive space 40 MB AIDA64 is completely vendor independent and is compatible with all PCs running 32 bit and 64 bit Microsoft Windows operating systems As far as the available functions are concerned it is irrelevant if we run AIDA64 on a server or client operating system AIDA64 Business Introduction USER INTERFACE The main functions of AIDA64 are accessible from the Menu bar Below the Menu bar we can find the Toolbar with which we can navigate through the pages Located in the left column below the Toolbar the Page menu displays a list of hardware and software categories details of which open in the information windows on the right File View Report Remote Favorites Tools Help ES 28M reo Menu Favorites Device Description E AIDA64 ca KINGSTON 5H10353906 50026B7226004AD9 b 1 Computer a WDC WD10EZRX 00L4HB0 WD WCC4J2602142 Motherboard p H mane iiai Attribute Description Threshold Value Worst Status D rver gt A Display Raw Read Error Rate 51 200 200 OK Value is normal gt a Multimedia Spinup Time 21 143 139 OK Value is normal 4 Storage Start Stop Count 0 100 100 OK Always passes E Windows Storage Reallocated Sector Count 200 OK Value is normal E Logical Drives Seek Error Rate 100 253 OK Always passes 100 OK Always passes 100 OK Always
92. e click the GPU column label If you only want to run the Memory Read benchmarks on both the GPU s and the CPU you need to double click the Memory Read label If you only want to run the Memory Read benchmark on only the GPU s you need to double click the cell where the requested benchmark result will appear when the benchmark is completed The benchmarks are executed simultaneously on all selected GPUs using multiple threads and multiple OpenCL context each with a single command queue CPU benchmarks however are only launched when the GPU benchmarks are completed It is currently not possible to run the GPU and CPU benchmarks simultaneously If there are multiple GPUs in the system the first result column will display an aggregated score for all GPUs Individual GPU results are combined added up and the column label will look like e g 4 GPUs If you want to check individual results you can either check only one GPU or click the Results button to open the results window Benchmark Memory Read Pinned Pageable Memory Write Pinned Pageable Memory Copy 15 MB Block 32 MB Block 64 MB Block 128 MB Block 236 MB Block 438 MB Block Single Precision FLOPS float float2 float floats ad OpenCL Device GPU Intel R HD Graphics 2500 IVB DT GT1 Result 4475 MB s 4475 MB s 1786 MB s 5213 MB s 5213 MB s 3936 MB s 13701 MB s 13087 MB s 13301 MB s 13504 MB s
93. e environment of PCs connected to the company network is By clicking on the categories we can create statistics diagrams join lines or delete sections Statistics 2 Wide Here we can see a summary table of the whole PC fleet showing the distribution of various Operating System Family 19 computers components in the network as well as indicating the computer names Using the table we can determine how uniform or heterogeneous the hardware and software environment of PCs connected to the company network is By clicking on the categories we can create statistics diagrams join lines or delete sections Windows 8 1 E 4 Linux EE 1 Windows 2008 R2 E 2 Windows 2012 B 3 Windows 7 O 7 Windows 8 Here we can also choose to look at the EE 2 Windows 8 1 individual reports one by one AIDA64 Business On the General tab in Audit Manager Preferences we can choose to display the file name instead of the name of the computer in Audit Manager We can also set Audit Manager to automatically load report from a database or a folder containing CSV files and we can choose to display or hide the grid lines in the Audit Manager window Components Summary General Filter Components Summary File menu General _ Use file name as computer name Ta Auto Load Automatically load reports from 8 No auto load Database Folder CSV report files Layout E3 Show grid lines
94. e page Mantle Here we can find detailed information about GPUs supporting the AMD Mantle graphics API such as GPU clocks TMU count profiling information API versions and video memory details Queue memory heap and device extension enumeration is also available for both GCN and GCN2 family Radeon GPUs Fonts This page enumerates all installed fonts Windows Audio This page lists the audio devices available in Windows PCI PnP Audio This page lists the PCI PnP audio devices HD Audio This page provides details about available High Definition Audio controllers and HD Audio devices Links to driver download websites are provided at the bottom of the page OpenAL This page displays OpenAL properties and provides information about OpenAL extension support Note OpenAL API calls may cause application or operating system faults when the audio driver does not fully conform to industry accepted standards therefore it is recommended to disable this page when completing a network audit 99 AIDA64 Business Page menu Audio Codecs This page provides information about the available audio codecs Double clicking on any item will open the Sound window File View Report Remote Favorites Tools Help SDS RM Trevor Menu Favorites Driver Description E AIDA64 4 Fraunhofer IIS MPEG Layer 3 Codec decode only gt 1 Computer 4 Microsoft ADPCM CODEC gt e Motherboard 4 Microsoft CCITT G 711 A Law and u Law CODEC
95. e to use at least one special file control string in the file name to avoid the reports overwriting each other This option must be used with the RMTHOSTS option explained below On the remote computers one AIDA64 instance has to be running in the background and accepting incoming connections automatically using either ACCEPT or ACCEPTBG command line options Example AIDA64 RMTREPORT c remotereports fHOSTNAME RMTHOSTS pciname pc2name pc3name CSV AUDIT RMTHOSTS this option can be used to specify the list of remote computers of which RMTREPORT creates reports This option can be used in two different ways RMTHOSTS lt host1 host2 gt The names of remote computers are separated by commas Do not use spaces between the computer names Example AIDA64 RMTREPORT c remotereports 6HOSTNAME RMTHOSTS pciname pc2name pc3name CSV AUDIT RMTHOSTS lt 0Olistfile gt The names of remote computers are located in an existing text file in which each computers name has to be listed in a separate line Example AIDA64 RMTREPORT c remotereports fHOSTNAME RMTHOSTS c aida64 remotepclist txt CSV AUDIT 9 6 3 CSV2HTM input file output file This option converts a CSV report file to a HTML report file CSV2SQL folder This option inserts the contents of a folder containing CSV report files to a SQL database 9 6 4 ALL the reports created will include all pages from the page menu SUM the r
96. ect SELECT INSERT and UPDATE in order to make report creation possible If we also want to allow users to delete from the database we can select DELETE Edit Privileges User aida64 Database aida64 Table Database specific privileges Check All Uncheck All Note MySQL privilege names are expressed in English Data SELECT INSERT UPDATE DELETE Structure CREATE ALTER INDEX DROP CREATE TEMPORARY TABLES SHOW VIEW CREATE ROUTINE ALTER ROUTINE EXECUTE _ CREATE VIEW _ EVENT TRIGGER QODODoOdOLD Administration _ cranT _ LOCK TABLES _ REFERENCES To allow AIDA64 to use the database we need to initialize the tables To do this we have to copy the DB MySQL sql query from the SQL Schema subfolder and run it on the newly created database 36 AIDA64 Business Preferences 3 7 5 1 Installing ODBC on each computer It is necessary to install a 32 bit MySQL Connector ODBC formerly known as MyODBC Driver on all networked computers This can be downloaded from http www mysal com products connector Installation is simple with the Group Policy Management Console We need to create a new GPO or we can select the one we already use when starting AIDA64 Right click the GPO and select Edit Here we can select if we want to assign the software installation to computers or users In order to do this we need to expand Computer configuration Policies Software
97. el SCPU1UTI ab Label SCPU2UTI ab Label SCPU3UTI ab Label SCPUAUTI ab Label SCPUCLK ab Label SCPUFSB ab Label SCPUMUL ab Label SCPUTHR ab Label SCPUUTI ab Label SDATE ab Label SDESKRES ab Label SDRAMFSB ab Label SDRVCFREESPC ab Label SDRVCUSEDSPC ab abel SDRVCUTI ab Label SEXTIPADDR ab Label SFREEMEM ab Label SFREESWAP ab Label SGPUIBUSTYP ab Label SGPU1CLK Data value not set CPU CPU GT Cores CPU IA Cores CPU Package Battery CPU Utilization CPU2 Utilization CPU3 Utilization CPU4 Utilization CPU Clock CPU FSB CPU Multiplier CPU Throttling CPU Utilization Date Desktop Resolution DRANM FSB Ratio Drive C Free Space Drive Used Space Drive E Utilization External IP Address Free Memory Free Swap Space GPU Bus Type GPU Clock Computer HKEY_CURRENT_USER Software FnalWireAIDA64 SensorValues Enable writing sensor values to WMI When we choose to share sensor values with external applications through the WMI sensor values are written to the following WMI path Root WMIAIDA64 SensorValues When AIDA64 is closed it deletes both the path and the values it contains from the WMI Temperatures are always in Celsius even if Fahrenheit is selected in the Preferences menu Sensor value labels are always displayed in English they are not localized Enable writing sensor values to Rivatuner OSD Server When we choose this option AIDA64 shares sensor readings te
98. en disk temperature is above here we can specify the degrees e Software installation uninstallation e Service installation uninstallation e Auto start list change e Network shares change e PCI devices list change e USB devices list change e SMART predicted hard disk failure e System memory size change e Computer name change e Winlogon Shell change Search 43 Report Report File Report Look P Schedule 3 1 Remarks a E mail y SMTP E Database E Custom Variables Y Content Filtering Ey Custom Components 55 Asset Profile gt AE Remote Features fi Custom Programs gt File Scanner 4 A Network Alerting A Alert Methods AAS Alert Triggers gt E Hardware Monitoring Alert Triggers A Trigger Description When virus database is older than Ga When system drive free space is below Ll cy When any local drive free space is below C eg When disk temperature is above El Software installation uninstallation 1 Service installation uninstallation ind Auto Start list change Network shares change 3 PCI devices list change USB devices list change Ga SMART predicted hard disk failure m System memory size change E Computer name change fy Winlogon Shell change Configure Cancel 49 days Celsius Apply AIDA64 Business Preferences HARDWARE MONITORING In this wndow we can configure the hardware m
99. ensors temperatures and voltages to this board 1568 replies Yesterday 05 38 AM Test Latency Cache amp M Benchmarking system performance 30 topics By Esa Everything about AIDA64 benchmarks 123 replies 2 No Network audit change tracking SQL databases Post your comments about audit features and all database related issues to this board Everything about SQL Access Oracle Network setup guide for AID 41 topics Ey pe 60 replies Report dates By Fiery Yesterday 08 27 AM Localization language modules 5 topics Post all localization related ideas problems to this board 13 replies G19LCD 3rd party solutions a By blacirat AIDA64 extensions scripts developed by users 3rd party applications utilizing AIDA64 capabilities 26 replies 6104 Total Posts 3628 Total Members bdragonques8830e Newest Member 113 Most Online 33 users are online in the past 15 minutes The moderating team Today s top 20 posters Overall top posters 3 members 28 guests 2 anonymous users See full list CONTACT If a default e mail client for example Outlook is configured in Windows clicking Contact in the Help menu will open it with a new message which can be sent to the AIDA64 support team AIDA64 Business Message HTML OPTIONS FORMAT TEXT REVIEW EE ll Attach File gt Q MS Attach Item Names Tags Zoom E Signature 7 Clipboard Fa Basic Text Include Zoom de SS Subject AIDA64 Business 85 AIDA64 Busin
100. eports created will include only the Computer Summary page HW the reports created will include only the pages listing hardware related information SW the reports created will include only the pages listing software related information BENCH the reports created will include the benchmark pages only AUDIT the reports created will include only the pages required by AIDA64 Audit Manager to compile a network audit and show audit statistics CUSTOM Server_IP_address AIDA64 profile rpf this option loads a customized report profile 88 AIDA64 Business Help 9 6 5 TEXT reports will be created in plain text format Plain text reports are usually not suitable for network audits HTML reports will be created in HTML HyperText Markup Language format HTML report layout can be customized in Preferences Report Report Look Although HTML reports are ideal if we want to print reports they cannot be used in AIDA64 Audit Manager and Change Manager MHTML reports will be created in MHTML format with HTML images MHTML reports are basically HTML reports with small icons included MHTML report layout can be customized in Preferences Report Report Look Although MHTML reports are ideal if we want to print reports they cannot be used in AIDA64 Audit Manager and Change Manager XML reports will be created in XML Extensible Markup Language format XML reports can be processed by 3rd party solutions
101. er Managing an inventory of hardware and software updates for an entire PC fleet on paper or even in Excel would require a lot of hard work and time However AIDA64 can provide a very detailed inventory of all the hardware and software components in a PC create a report of these even automatically if required and send these reports to any selected computer or server From there all the system administrator needs to do is thumb through the reports and solve any potential problems Recommended report format AIDA64 supports several report formats but it is recommended to save reports in CSV format or a database as these are easy to work with later and require no conversion or post processing HTML files can be used for occasional reports as well as for publication on the web while we can use any of the supported formats according to our needs We need to make sure that reports are created in the same language For example if we have created reports in Hungarian but would like to change the report language to English it is recommended to store the new reports separately from those previously generated as otherwise Change Manager will detect changes in almost all data We also need to make sure that we include the same components in the reports that is that we use identical report profiles or store those which were made using different report profiles separately REPORT WIZARD With Report Wizard we can easily create reports in AI
102. es the offset to be applied on the selected item An offset of 10 means lowering the input value by 10 An offset of 20 means adding 20 to the input value Search Correction fh General ES Correction Item Type Ratio Offset ly a rs Layout Motherboard Temperature 3 0 Stability A cru 1 Core 1 Temperature 1 9 gt J Report a CPU Temperature 2 0 gt E mail A 12v Voltage 2 0 E Database BS CPU GT Cores Voltage 1 15 fll Summary i Custom Variables Y Content Filtering a Custom Components 55 Asset Profile gt ME Remote Features fi Custom Programs D File Scanner b Network Alerting 4 E Hardware Monitoring O Update Frequency E Sensor Icons gt E OSD gt fH Desktop Gadget gt Mi LCD E E SensorPanel E Logging fi External Applications EM ody Delete Cancel 62 AIDA64 Business View 4 VIEW In the View menu we can configure the layout of the information window and hide display the Toolbars and the status bar We can also select the icon sizes expand and collapse all main categories in the Page menu tree and refresh the information on certain pages e Toolbars Displays or hides toolbars e Status Bar Displays or hides the status bar at the bottom of the program window e Large Icons Displays large icons in the information windows e Small Icons Displays small icons in the information window e List Items are sho
103. ess Help LICENSE This menu item will display the end user license agreement in a pop up window If we use the AIDA64 ZIP package we automatically accept the terms of the license agreement AIDA64 END USER LICENSE AGREEMENT The software and materials provided by FinalWire Ltd are licensed NOT SOLD and are available for use only under the terms described hereafter Please read this agreement carefully By downloading installing copying or otherwise using the software and materials you agree to be bound by the terms and conditions of this agreement If you do not agree with all of the terms and conditions of this agreement do not download install copy or otherwise use the software or materials provided by FinalWire Ltd The term Software used throughout the agreement includes any modified versions or updates of the Software licensed to you by FinalWire but does not include source code for the FinalWire software product TERMS amp CONDITIONS GRANT OF LICENSE Subject to the terms and conditions of this Agreement FinalWire grants you a non exclusive and non transferable license only to a Install and use for personal or internal business purposes one copy of the Software on a single computer COMMAND LINE OPTIONS AIDA64 Business offers several command line options with which we can customize network audit automated report creation remote connections and some security features Option Description El Usage AIDAGA R
104. esses management solution for engineers businesses Compare the four AIDA64 editions Have a look at our prices 84 AIDA64 Business Help AIDA64 FORUM Clicking on AIDA64 Forum in the Help menu will open the English language support forums The developers of the software are regular visitors to the forums and are happy to answer technical questions and troubleshoot any issues http forums aida64 com 4 AIDAGA Discussion Forum Forums AIDA64 Recent Topics Extreme Edition Licensing how many i i E AIDA64 PI for AlphaCool installs per machine General Discussion 281 topics D ugin for AlphaCoo 5 By Naudnaud Consumer Yesterday 11 25 PM Use this board for general discussion about AIDA64 1014 replies Today 12 15 PM Incorrect value of Country IMoJi Nov 23 2012 09 08 AM E SensorPanel a new flexib Brainstorming 96 topics By Fien Report dates All the new ideas and suggestions for AIDA64 Post your thoughts to this board 447 replies ssterday 07 43 PM Fernando Gregoire Nov 23 2012 07 23 AM B 292 topi This isn t necessarily ASRock AD2500B ITX mobo single vie ital ave By Fiery fan always shows as cpu fan Post all bugs you may find to this board 1832 replies Today 09 19 A afj Nov 22 2012 09 38 PM n Is my RAM running in ECC mode Hardware monitoring 278 topics F Asus Al Suite and Aida64 Consumer Nov 22 2012 06 11 AM z By Soul Reaver Post every questions and concerns about s
105. etBIOS name as well as the DNS host and domain names of the PC are listed here DMI Here AIDA64 displays the computer s DMI table in a human readable format DMI is a standard developed by DMTF and stands for Desktop Management Interface DMI information includes descriptions of hardware components such as BIOS motherboard processor memory controllers port connectors system slots etc DMI information should be provided by the component or PC manufacturers and can often be incomplete and inaccurate IPMI Here AIDA64 displays the Intelligent Platform Management Interface IPMI system log and sensor information 93 AIDA64 Business Page menu Overclock This page displays CPU properties CPU speed and cache information as well as motherboard chipset BIOS and graphics processor properties Power Management This page displays information about the PC s power source and battery if applicable Temperature and Capacity monitoring input voltage output voltage output current and energy consumption measurements are also provided for HID capable UPS devices Portable computer This page displays mobile PC related physical information as well as Intel Centrino platform compliance information Sensor This page provides motherboard CPU and HDD sensor information as well as cooling fan RPM voltage and power values in real time MOTHERBOARD CPU This page provides processor related information including CPU type clock s
106. etwork audit or remote control and in such scenarios disabling it can save up to 10 MB of system memory Enable DMI page This option displays or hides the Computer DMI page which displays information about the BIOS the motherboard the chassis the controllers as well as the slots connectors and sockets integrated on the motherboard The reliability and accuracy of DMI information depends on the motherboard or computer manufacturer responsible for providing this data It is recommended that this page is disabled if DMI data seem inaccurate Enable OpenAL page This option displays or hides the Multimedia OpenAL page which displays information about the Open AL interface OpenAL API calls may cause application or operating system faults when the audio driver does not fully conform to industry accepted standards It is recommended that this page is disabled to avoid any issues during network audits Enable OpenGL page This option displays or hides the Display OpenGL page which displays information about the OpenGL interface OpenGL API calls may cause application or operating system faults when the video driver does not fully conform to industry accepted standards It is recommended that this page is disabled to avoid any issues during network audits 19 AIDA64 Business Preferences Enable DirectX menu This option displays or hides all pages under the DirectX menu This menu may not be necessary when doing
107. f required we can specify a server port as well Database Here we can specify the database name or if we use MS Access the location of the Access database file We will first need to add authentication information so that AIDA64 can read the database list from the server Driver Here we have to select the appropriate driver If it is not installed yet we have to install it first Windows authentication When this option is enabled the actual user is authenticated on the SQL server using his her current logon credentials We need to ensure that we grant write permission to users of the database Test button We can test the actual SQL connection configuration by pressing the Test button Only a connection test is performed no tables are created and no records are inserted during the test process 32 AIDA64 Business Preferences 3 7 1 BORLAND INTERBASE FIREBIRD MSDASQL If we use an InterBase or Firebird database we can specify a data source although this is not required We need to specify the server name or IP address and the port required for the database connection then select the database and the driver We can also add a user name password combination or choose Windows authentication If we want to save the reports to a Borland InterBase database it is necessary to install the InterBase Client and an InterBase ODBC driver on all networked computers If we want to save the reports to a Firebird database it is nece
108. ftware on his or her computer If required we can even intervene through remote control in such cases On the Network Alerting page we can select how often we want ser Network Alerting AIDA64 to check the status of alert A Number of minutes between checking for alerts 2 triggers as well as how often we 3 Number of hours between sending repetitive alerts 24 would like to receive alerts of the oe a Store system configuration details i same unresolved issue With the gt fontos ARIAS latter option Number of hours b e O Custom folder between sending repetitive alerts 4 0 emai we can configure how often AIDA64 Poch should send out the same alert jy cee arisbles Y Content Filtering message For example when an g Custom Components automatic virus database update BE Asset Profile gt ME Remote Features fails for some reason and 4 hours D J File Scanner is selected for this option AIDA64 dh Network tng will send the alert Virus database is Az Alert Triggers F gt E Hardware Monitoring too old every 4 hours or 6 times a day We can choose to store system configuration in the TEMP folder of the logged on user Root folder on the system drive or Custom folder 47 AIDA64 Business Preferences 3 16 1 ALERT METHODS On the Alert methods page we can choose from six alerting methods and we can select more at once e Display a
109. gle command line R E FTPUPLOAD RMTREPORT Using more of these options simultaneously could cause unexpected issues 2 Only one of the following options can be used in a single command line RMTREPORT ACCEPT ACCEPTBG ACCEPTMIN Using more of these options simultaneously could cause unexpected Issues 3 Only one of the following options can be used in a single command line ALL SUM HW SW BENCH AUDIT CUSTOM Using more of these options simultaneously could cause unexpected Issues 4 Only one of the following options can be used in a single command line TEXT HTML MHTML XML CSV MIF INI DATABASE Using more of these options simultaneously could cause unexpected issues 9 6 1 REPORT R reportfile this option can be used to create a report and save it to file When no file name is specified the report will be written to the file specified in Preferences Report Report File It is recommended to specify a full path name for the report file in the command line For a network audit we should use UNC paths in folder names instead of using a mapped network drive Reports are automatically compressed if this option is enabled in Preferences Report In the report file names we can use control strings see section 10 6 10 Example AIDA64 R server share folder BHOSTNAME CSV AUDIT SILENT SAFE E address this option can be used to create a report and send it in e mail When no address is spec
110. gure four TCP IP ports used for remote functions These ports should be configured in the firewall and restricting traffic on these ports to the intranet is also important to prevent any attacks or sniffing on AIDA64 remote communications traffic Default remote control ports are 2345 for remote system information 2346 for remote monitoring 2347 for remote reporting and 2348 for remote control If any of the selected ports are already in use by another application we can select another one which facilitates firewall configuration We can set a password for the remote connection modes to ensure that only authorized persons can connect to remote computers With AIDA64 we can take screen shots on remote computers and we can configure the screen shot properties Search Language Languag ify General a Layout Cs Stability 4 7 Report E Report File 09 Report Look Remarks a E mail A Database Summary g Custom Variables Y Content Filtering el Custom Components ke Asset Profile a PE Remote Feature 9 Remote Control fia Security El Custom Programs b J File Scanner D Network Alerting b E Hardware Monitoring Full screen active window and compression quality here 3 13 1 REMOTE CONTROL To improve Remote Control performance here we can disable user interface effects and the desktop wallpaper on remote computers lt is also possible to change the deskto
111. ia O eo codecs information b a Multimedia nc E Check for Updates Je d h E Storage b Storage E Network El About gt EY Network e Di ee E DirectX DirectX devices information gt E Dire a a z k al eie A Devices PCI AGP PnP USB PEMCIA devices list printers information l El Software E Software Software subsystem information bM Security W Security System security information gt B come al Config System configuration information hy Ef Database E Database Database BDE ODBC information 73 Benchmark Benchmark Measure system performance Menu Favorites Page ART information El AIDAG6A 1 Local Copyright c 1995 2014 FinalWire Ltd AIDA64 ONLINE Clicking on AIDA64 Online in the Help menu will open the local AIDA64 website corresponding to the selected UI language If there is no AIDA64 website available in the GUI language the English language website will load by default Xx AIDAG4 Products Prices Download Support 3X Choose the edition that best suits your needs Les Ba lex AIDAG4 Encineen lt U T i AIDAG4 Extreme a canon a e sem masse g 1d AIDA64 Extreme AIDA64 Engineer AIDA64 Network Audit AIDA64 Business System information System information Comprehensive hardware Comprehensive network diagnostic and benchmarking diagnostic and benchmarking and software inventory inventory and IT asset tool for home users tool for IT technicians and solution for busin
112. iately add the new software to be installed to the list File Action View Help es aa E a B am E aida64s SRVR2012 ABSEIRA LOCAL 4 amp Computer Configuration 4 C Policies a 7 Software Settings A Software installation p 5 Windows Settings p D Administrative Template p D Preferences 4 2 User Configuration p Policies p L Preferences Name Version Deployment state Source MySQL Connector ODBC 5 2 5 2 Assigned SRVR2012 Shares mysql connector odbc 5 2 6 win32 msi At this point only one thing remains to be done refreshing the group policy on the clients AS we set up an event that runs at start up we will need to restart the PCs 3 7 5 2 AIDA64 settings If we use a MySQL database we can specify a data source although this is not required We need to specify the server name or IP address and the port required for the database connection as well as the user name password of the created user then select the database and the driver MySQL optimization which accelerates the process of inserting new records to the database requires MySQL 3 22 5 or newer Then we have to click the Test button to check the settings Finally we need to check the firewall settings We should open TCP UDP port 3306 to allow all computers on the network to connect to the database Search _ bis Pa a 437 Report Report File 4 E mail SMTP E w Custom Variables Pm Y Content Fi
113. ified the report is sent to the To address configured in Preferences Report E mail Reports are automatically compressed if this option is enabled in Preferences Report Example AIDA64 E admin company com CSV AUDIT SILENT SAFE SUBJ lt subject gt this option can be used with E to specify the subject of the e mail to be sent In the subject we can use control strings see section 10 6 10 Example AIDA64 E admin company com SUBJ Report of HOSTNAME CSV AUDIT SILENT SAFE FTPUPLOAD reportfile this option can be used to create a report and upload it to a FTP server When no file name is specified the report will use the file name configured in Preferences Report Report File Reports are automatically compressed if this option is enabled in Preferences Report The FTP connection has to be configured in Preferences Report FTP Example AIDA64 FTPUPLOAD HOSTNAME CSV AUDIT SILENT SAFE 87 AIDA64 Business Help 9 6 2 REMOT RMTREPORT reportfile this option can be used to create report files of remote computers and save them to files When no file name is specified the report will be saved to the file configured in Preferences Report Report File lt is recommended to specify the file name with a full path name in the command line Reports are automatically compressed if this option is enabled in Preferences Report When more than one computer is to be interrogated it is imperativ
114. into an SQL database Before using the SQL interface SQL connection parameters have to be ate aa configured in Preferences Database Please choose a desired report format Plain Text If we select this format an ADO file will also be OHTML N i 8 MHTML created containing a message about the status of the report creation process In case we want to receive such a message from each computer we need to insert the path in the Output folder field in Settings Report File using the date variable at the end of the path server Shares AIDA64Business report DAT E and typing S5HOSTNAME in the File name field After selecting the report format we can start the report creation process by clicking Finish QUICK REPORT We can create quick reports of the currently active category in the Page menu tree We can save these summaries in a TXT HTML MHTML XML CSV MIF INI or Database file For example if the Storage category is active in the Page menu only pages from this category will be included in the quick report 5d Remote Favorites Tools Help gt Ny Report Wizard ae gt EE 7 E Quick Report All pages a Plain Text fs o MHTML ption system summary XML O cessors memory chipset BIOS information ram csv Services processes drivers information a MIF E Display INI monitors desktop information amp Multimedia EF Database es audio and wideo codecs information 3 Storage ra
115. is page displays operating system information including Windows version license information product key session statistics and operating system components and features File View Report Remote Favorites Tools Help ES 28M Rion Menu Favorites ES AIDA64 gt 1 Computer gt Motherboard 4 E Operating System IAY Operating System da Processes Field y Operating System Properties fz OS Name a OS Language a OS Installer Language OS Kernel Type fy OS Version Value Microsoft Windows 8 1 Professional English United Kingdom Hungarian Hungary Multiprocessor Free 64 bit 6 3 9600 17085 Win8 1 RTM 34 OS Service Pack 10 06 2014 Li OS Root CAWINDOWS 8 DLL Files i PD License Information R Registered Owner ABSEIRA Ltd A Registered Organization ABSEIRA Ltd Product ID 00178 10927 91136 AA968 Product Key DN6M7 8DG6R FBWGJ VHRQY 39H3H YU Product Activation WPA Not Required b AL Display gt ij Multimedia gt 83 Storage gt i Network gt E3 DirectX gt g Devices gt El Software gt M Security gt 3 Config gt Database gt 15 Benchmark E Current Session E Computer Name OFFICE103 a User Name oliver mesztrics 55 Logon Domain ABSEIRA 16 UpTime 329783 sec 3 days 19 hours 36 min 23 sec Operating System Ki Local Copyright c 1995 2014 FinalWire Ltd Processes This page lists all running processes togethe
116. isplay mode e g Matrox DualHead e Monitor Diagnostics will display the same test images on each physical display of the multi display system In multi display stretched desktop mode Monitor O Diagnostics will display a single test image stretched to all displays of the multi display system 82 AIDA64 Business Tools 8 7 System Stability Test can be used to stress all major system components CPU caches memory hard disk drives at once and find any possible stability or cooling issues Individual stress testing processes can be launched one by one or simultaneously and can be enabled disabled any time during the test In the log window we can see when selected tests were started and stopped On the graphs we can pata Date amp Time T Status me OA Stress FPU 30 05 2014 11 01 37 Stability Test Started monitor CPU usage and the temperature of 30 05 2014 11 03 53 Stability Test Stopped selected hardware components We can select ca tress local disks w _ Stress GPU s various parameters we would like to monitor using the available tabs Temperatures Cooling fans Voltages Power On the Statistics tab a summary is shown with the minimum maximum and average values indicated for all monitored parameters The module also shows battery status if applicable as well as the date and time when the test was started and the time elapsed since Temperatures Cooling Fans Voltages
117. line switch This works in the same way as creating reports of selected torar Y ME BIOS Type pages that can be loaded later from a 3 seais en file the difference being that Summary fcsome settings are stored together with all other settings in the aida64 ini file under the INI group heading Sum CUSTOM VARIABLES Here we can define up to 50 custom variables Selecting the variable and then clicking on Configure we can specify the location where the value for the variable is located We can choose from 4 options m SPD Memory Modules Select All Clear All gt J gt File Scanner D Network Alerting Q Hardware Monitoring Cancel Apply Registry entry The information will be extracted from the Windows Registry In the Path field the full Registry path including the root key HKCR HKCU HKLM and the name of the requested value have to be specified Example HKEY_LOCAL_MACHINE SOFTWARE ESET ESET Security CurrentVersion Licenselnfo UserName 40 AIDA64 Business Preferences Environment variable The easiest way to access a list of available variables is to navigate to Config Environment in the AIDA64 Page menu The value will be extracted from the selected environment variable Line of text file We can display information from a selected line in a text file We need to specify the full path name for the file and the number of the line we want to be displayed Ent
118. ltering g Custom Components 2 5 Asset Profile gt Remote Features fill Custom Programs gt File Scanner A Network Alerting AA Alert Methods gt Q Hardware Monitoring Database E Provider MySQL MSDASQL o Data source Server SRVR2012 Server port 3306 Database AIDA64 Driver MySQL ODBC 5 2 Unicode Driver User AIDA64 Password Use MySQL optimization requires MySQL 3 22 5 or later Cancel Apply 3 7 6 ODBC MSDASQL If we use a different database listed in the provider list and have an ODBC driver available for it it is possible to use that database too 38 AIDA64 Business Preferences 3 7 6 1 MariaDB Instructions to create and configure the database are found in the section 3 7 5 MySQL while the installation of the ODBC driver is described in 3 7 5 1 Installing ODBC on each computer If we use a MariaDB database we can specify a Windows data source although this is not required We need to specify the server name or IP address and the port required for the database connection as well as the user name password of the created user then select the database and the driver We have to click the Test button to check the settings Finally we need to check the firewall settings We should open TCP UDP port 3306 to allow all computers on the network to connect to the database Search Database Eh Provider ODBC MSDASQL Data sour
119. mail Address C Logon Domain 9 Date Time s Motherboard KA CPU Type Motherboard Name HE Motherboard Chipset m System Memory BE BIOS Type Fv Communication Port amp Display Select All Clear All File menu On the Summary tab we can choose the components we would like to see in the individual reports in Audit Manager The components we deselect will not be visible in the list If we modify the settings on the Components tab a warning will appear on the status bar The page is outdated Press Refresh button to update it In such cases we need to click on the Refresh button on the toolbar File Edit Report Audit Er Ore q Refresh ES Preferences Audit 13 ga List 1 HW Component List 2 SW Component 23 List 3 DMI Component i List 4 Computer Statistics 1 Narrow EA Statistics 2 Wide ill OFFICE101 cll OFFICE102 JE OFFICE103 ill OFFICE104 91 OFFICE106 JE OFFICE107 JE OFFICE108 E OFFICE110 JM OFFICE119 Statistics 2 Wide Field Es Operating System Family Es Linux Ea Windows 2008 R2 Es Windows 2012 E Windows 8 E Windows 8 1 CPU Type DualCore Intel Core 2 Duo E6300 1 DualCore Intel Core 15 Oo QuadCore Intel Xeon E5520 m System Memory Size E 2048 MB mA 9192 MB Em 12283 MB 11 Computers OFFICE106 OFFICE107 OFFICE104 SEWR3 SAVR SAVR2012 OFFICE101 OFFICE103 OFFICE119
120. menu we can hide reference results and or user results by clicking the Results button on the toolbar Pages required for audit This profile includes all pages required in the network audit and change tracking modules of AIDA64 Audit Manager Change Manager Although this profile was designed with these AIDA64 services in mind reports based on this report profile can be processed by 3rd party solutions as well to make similar network audit Statistics Pages included in this profile are typically short and are compiled quickly resulting in small report files Custom selection This option offers us a flexible way to compile a custom report profile using the Custom report profile page of Report Wizard Custom report profiles can be saved to a report profile file with RPF file extension which can be used for automatic command line based report creation with the command line option R CUSTOM lt RPF file path gt Load from file This option offers us a quick way to load a previously created custom report profile with RPF file extension The browse button can be used to select the file in Windows Explorer 65 AIDA64 Business Report 5 1 2 REPORT FORMAT Here we can select the format in which we would like to save our reports Available options are e Plain text e CSV e HTML e MIF e MHTML e INI e XML e ADO to be inserted in a database ADO to be inserted in a database If we select ADO the report will be inserted
121. mperatures voltage and fan readings with Rivatuner s OSD Server through the shared memory RTSSSharedMemoryV2 Rivatuner OSD Server is capable of displaying these values on an OSD panel even during full screen 3D games or video playback 60 AIDA64 Business Preferences 3 17 9 ALERTING AIDA64 can send alert notifications of several hardware related issues Here we can enable alerting and specify how often we would like to receive alerts of the same issue The latter option is useful for events that persist for example when a cooling fan comes to a halt and does not restart We can add new alert triggers by clicking New and edit existing triggers by clicking Modify We can define individual labels for each alert trigger and we need to set the threshold values for each by filling in the value is below and or value is above fields We can select the alert method on the Actions tab Available options are displaying an alert window shutting down the computer playing a user selected WAV file running a user selected program or command and sending a notification e mail the subject field of which is customizable lf we choose to send e mail notifications we need to configure the e mail sending options in Preferences E mail Search Alerting A Enable alerting Number of hours between sending repetitive alerts 2 Gh Stability gt 37 Report F E mail Alert Item Type Alert Trigger
122. n alert window If this option is enabled AIDA64 will display warning windows on the computer where the alert event is detected e Send an e mail to If this option is enabled AIDA64 will send warning e mails to the specified address Alert e mails should usually be delivered to the network administrator The Test button can be used to test the e mail settings which has to be configured on the page Preferences E mail e Send an entry to a log server If this option is enabled AIDA64 will send warning messages to the specified log server The Test button can be used to send a test alert message to the log server Note that when the message cannot be sent for example due to the unavailability of the log server no error message will be displayed e Send a Windows message to If this option is enabled AIDA64 will send warning messages to the specified computer through Windows Messaging layer To use this function the Messaging service has to be enabled on the selected computer The Test button can be used to send a test alert message e Write to a TXT log file If this option is enabled AIDA64 adds an entry to the specified TXT log file Please make sure to specify a file that can be accessed with write only permission by all networked users Using a UNC path e g server share folder logfile log is recommended e Write to aHTML log file If this option is enabled AIDA64 adds an entry to the specified HTML log file Please make
123. nal hardware or software auditing methods but are important for a full computer profile Such properties include serial number date of purchase date of last repair location user s name etc Asset Profile information needs to be configured on the AIDA64 running on the central computer In this windows we can add new profiles and modify or delete existing ones Q Language ify General GE Stability 4 7 Report E pu Report File ion Report Look a Schedule Ml Summary if Custom Variables Content Filtering ll Custom Components a IE Remote Features S Remote Control Custom Programs D J File Scanner D Network Alerting D E Hardware Monitoring Asset Profile E ll ALL pM OFFICE101 Ml OFFICE102 Ml OFFICE103 jl OFFICE104 Field Computer Role E Serial Number Mi Asset Tag E Purchase ID E Date of Purchase E Value of Purchase a Date of Last Repair E Value of Last Repair 5 Department e Location 2 Owner s Name xy User s Name User s Phone Number i Comment 01 11 2012 Office Budapest ABSEIRA Ltd Apply When adding a new profile or modifying an existing one we can specify the name of the computer or we can extend the profile to all computers by pressing the All button which changes the computer name to ALL 43 AIDA64 Business Preferences REMOTE FEATURES With these settings we can confi
124. ng report file will be ine Ry Hardware related pages very large typically over 2 MB in size It is iris recommended to compress the report files in the e E E S long run to save storage space especially if we O Pages required for audit use AIDA64 in a network of several hundred PCs 8 Custom selection Load from file Cancel System Summary only This profile includes only the Computer Summary page in the report It is useful if we want a quick summary of the hardware and the operating system and we do not need any further software information It is possible to select the items we would like to see on the Summary page in Preferences Summary Hardware related pages This profile includes all pages containing hardware configuration information Hardware reports typically do not include any confidential information except for motherboard and system serial number IP and MAC addresses Software related pages This profile includes all pages containing software configuration information Software reports typically include a great deal of confidential information and should be treated accordingly We can exclude all software license information from the reports by using the NOLICENSE command line switch Benchmark pages This profile includes all benchmark pages under the Benchmark category that is the results of all memory and CPU benchmarks If we select any of the subcategories in the Benchmark
125. ntervention is allowed can be used with the options R E or FTPUPLOAD e SHOWPCANCEL Using this option the report creation progress can be tracked and user intervention is allowed can be used with the options R E or FTPUPLOAD e SHOWS Using this option the startup process of AIDA64 can be tracked on screen e NOICONS AIDA64 will not display icons on its user interface This option can be used to save network bandwidth e INIFILE lt Server_IP_address AIDA64 aida64 ini gt This option can be used to tell AIDA64 where to load the settings from e DELAY seconds This option can be used to delay the startup of AIDA64 so that other programs can load faster e IDLE This option sets AIDA64 application process to idle lowest priority 90 AIDA64 Business Help e NOLICENSE This option can be used to disable and hide all software license related information including the Software Licenses page 9 6 10 VARIABLES With variables we can use dynamic path and file names in command line switches e HOSTNAME Inserts host name e USERNAME Inserts current user name e DOMAIN Inserts current logon domain e IPADDR Inserts primary network adapter IP address aaa bbb ccc ddd e MACADDQ Inserts primary network adapter MAC address AABBCCDDEEFF e MACADDR Inserts primary network adapter MAC address separated by hyphens AA BB CC DD EE FF e UUIDMAC Inserts DMI System U
126. ognizing devices not identified by Windows listed as Unknown devices and providing information about them which helps us find the appropriate drivers File EPZA ro View Report Remote Favorites Tools Help Menu Favorites E AIDA64 gt gl Computer gt E Motherboard gt Operating System gt 3 Server gt A Display gt a Multimedia gt Storage EY Network a 2 DirectX A DirectX Files 2 x DirectX Sound hl DirectX Input gt 24 Devices gt fe Software gt M Security gt A Config DirectDraw Driver Description Primary Display Driver Field DirectDraw Device Properties DirectDraw Driver Name DirectDraw Driver Description El Hardware Driver Hardware Description Direct3D Device Properties Rendering Bit Depths Z Buffer Bit Depths Multisample Anti Aliasing Modes Min Texture Size Max Texture Size Unified Shader Version ES DirectX Hardware Support Value display Primary Display Driver igdumdim32 dll 10 18 10 3621 Intel R HD Graphics 16 32 16 24 32 MSAA 2x MSAA 4x MSAA 8x 1x1 8192 x 8192 5 0 DirectX v11 0 gt EF Database 12 Benchmark DirectX Video E Direct3D Device Features jE Local Copyright c 1995 2014 FinalWire Ltd Physical Devices This pages lists the physical devices found in the PC All PCI PCI Express AGP PnP or USB devices are listed here including those integrated
127. on area will appear to inform the user that there was a AIDA64 Client Connected Y KX successful or unsuccessful attempt to establish a remote Connection Type Remote Monitor User Mame oliver mesztrics connection During the remote session the AIDA64 icon in the notification area will turn red It is possible to hide the bubble notification and the icon using the SILENT command line option Computer Name IRODA101 1x31 4 E y Ji OM HUN 172013 On the Connected tab the following information is shown for remote computers e IP address or computer name The icon indicates that the remote computer is a server or a client or a portable computer e Computer name e The name of the logged on user e Operating system version e Uptime since last Windows launch e idle time that is the time since the user has not used the computer e CPU usage e Total and free memory e Total and free disk space e HDD SMART status e Network usage e Anti virus status e Number of running processes e Active window Using the Remote Monitor module we can send messages to the remote user and for example browse files run programs end processes and take screen shots on the remote computers We can perform these operations on all networked computers if we want to For example if we type notepad in the Run program field Notepad will launch on all computers Of course any command including command line switches can be used here
128. on on Remote Access Services RAS such as dial up ISDN and DSL settings Net Resources On this page we can have an overview of our entire network including workgroups domains the workstations and servers they include as well as shared folders and printers IAM This page provides information about the e mail accounts used in the installed e mail clients eg Outlook Outlook express Internet This page provides information about Internet Explorer and the proxy settings 102 AIDA64 Business Page menu Routes This page lists the defined TCP IP network routes IE Cookie This page lists the Internet Explorer cookies stored on the computer Double clicking most cookies will open the corresponding website in the default browser By pressing the Clear list button on the taskbar we can delete all cookies stored on the computer at a single click Browser History This page displays Internet Explorer browsing history Double clicking any item will open the corresponding URL in the default browser DirectX Files This page lists all installed DirectX files Double clicking any item will open the file properties window DirectX Video This page provides DirectDraw device information Double clicking the drivers will run the DirectX Diagnostics tool Links to the graphics card manufacturer s driver download website are provided at the bottom of the page 64 File View Report Remote Favorites Tools Help SDC SRM Zion
129. onitoring services Search Hardware Monitoring _ Display temperatures in Fahrenheit y General r Enable CPU throttling measurement Layout CG Stability Enable disk temperature measurement A gt 57 Report Disk temperature polling frequency 20 sec E mail LJ EX Database Decimal digits for voltage values 3 a Y re Y B imal digits for clock 0 o a ci Vee Decimal digits for clock speeds Y Content Filtering Tjmax temperature Automatic v 24 Custom Components oe Asset Profile Degree symbol gt Remote Features El Custom Programs gt JO File Scanner D Network Alerting a Hardware Monitoring E Sensor Icons gt EY OSD gt E Desktop Gadget gt LOD Q SensorPanel Automatic Custom Cancel Apply Display temperatures in Fahrenheit In the sensor icons the OSD panel the Desktop Gadget and the SensorPanel temperature values are displayed in Fahrenheit rather than Celsius when this option is enabled Enable CPU throttling measurement This option can be used to enable CPU throttling measurement on Intel processors Measuring throttling may cause system instability Throttling is a self protection mechanism in Intel processors to prevent physical damage due to overheating Enable disk temperature measurement Here we can enable or disable disk temperature monitoring Disk temperature polling frequency With this option we c
130. onnecting to the local computer This feature is selected by default to ensure maximum security and privacy gt Operating System Remote Monitor iD Remote System Information EA Remote Control O Accept Incoming Remote Connections A Ignore Incoming Remote Connections aa ey ees MS e srry Services processes drivers information j Server Server information amp Display Multimedia E Storage EP Network Directx Ey Devices El Software e Security 3 Config E Database Benchmark Display adapters monitors desktop information Multimedia devices audio and video codecs information Hard disks CD amp DVD drives SMART information Network subsystem information DirectX devices information PCI AGP PnP USB PCMCIA devices list printers information Software subsystem information System security information System configuration information Database BDE ODBC information Measure system performance Ni Local Copyright c 1995 2014 FinalWire Ltd 13 ask permission to communicate through the Windows firewall we have to grant permission If for some reason the firewall notifications fail to appear or we use a 3rd party firewall we need to add the firewall exceptions manually for these two files Alternatively this feature can be activated automatically at AIDA64 startup by using either the ACCEPT or ACCEPTBG or ACCEPTMIN command line option For example aida64 e
131. p resolution and the desktop color depth on remote computers and we can choose to ignore all inputs on the local computer as well Holding the mouse pointer over the information bubble will display some tips for each available option 3 13 2 SECURITY AIDA64 allows us to specify those computers user names or IP addresses that are authorized for initiating remote connections Remote Features Lo TCP IP Port Password Remote system information 12345 trikk Remote monitoring 2346 week Remote reporting wee Remote control wee Screen Shot sai 0 Shot type o typ 8 Full screen Active window Compression quality 50 a 1 worst 99 best Search Language oly General E Layout Gh Stability ai Report E Report File p Report Look o Schedule ij FTP El D Remarks a 7 E mail E Database Summary Y Custom Variables Y Content Filtering a Custom Components okie Asset Profile a Remote Features om Security i Al Custom Programs b gt File Scanner gt Network Alerting D E Hardware Monitoring Remote Control Lo User interface effects Leave unchanged Desktop wallpaper Leave unchanged Desktop resolution 1600 x 1200 Desktop color depth Leave unchanged _ Ignore all inputs view only Search D 4 Report a E mail iB S
132. passes 253 OK Always passes 100 OK Always passes 200 OK Always passes 200 OK Always passes OK Always passes 200 OK Always passes 200 OK Always passes 253 OK Always passes 200 OK Always passes 253 OK Always passes 3 a Physical Drives Power On Time Count Er Optical Drives Spinup Retry Count Calibration Retry Count Power Cycle Count Power Off Retract Count Load Unload Cycle Count Temperature Reallocation Event Count Current Pending Sector Count Offline Uncorrectable Sector Count Ultra ATA CRC Error Rate Write Error Rate oOo oo oo oo Oo ooCo so b EY Database b 13 Benchmark a SMART Ki Local Copyright c 1995 2014 FinalWire Ltd The Page menu list is grouped into the following categories e Computer e Server e Network e Security e Motherboard e Display e DirectX e Config e Operating e Multimedia e Devices e Database System e Storage e Software e Benchmark The information window displays specific information pertaining to each category from the page menu A right click on any single item will copy the related page information to the clipboard In the center of the status bar at the bottom of the window we can see the remote connection status which is Local by default However when AIDA64 is connected to a remote computer the bar will display Remote and the name of the remote computer AIDA64 Business File menu 2 FILEMENU The settings and all functions related to managing re
133. peed multiplier cache size and packaging For Intel processors a link to a page on the manufacturer s website listing the specifications is also provided Available for each processor core CPU utilization data is updated in real time CPUID This page displays processor information using the CPUID instruction Information about the availability of instruction set extensions security power management and virtualization features is also provided Motherboard This page displays information about the motherboard including name front side bus properties memory bus properties chipset bus properties and manufacturer information File View Report Remote Favorites Tools Help ES UEM Frm Menu Favorites Field Value E AIDA64 v4 50 3000 Motherboard Properties p 1 Computer Motherboard ID 63 0100 000001 00101111 101111 ChipsetS1APTCO15_BIOS DATE 0 Motherboard Name MSI B75MA P45 MS 7798 gt Front Side Bus Properties gt Bus Type gt Real Clock Effective Clock m Memory Bus Properties 4 AY Operating System m Bus Type Dual DDR3 SDRAM Y pa E Bus Width 128 bit gt ME Display EE DRAM FSB Ratio 20 3 gt 4 Multimedia Ei Real Clock 667 MHz DDR gt 83 Storage E Effective Clock 1333 MHz Y amp Network m Bandwidth 21333 MB s gt GP DirectX gt Ey Devices ME Chipset Bus Properties p 45 Software BE Bus Type Intel Direct Media Interface v2 0 gt MA Security D 183 Config Motherboard Physical Info gt D
134. port iy WDDM Version E Architecture amp Architecture Bi Execution Units EU ME L1 Instruction Cache Value Intel Ivy Bridge DT Integrated Graphics Controller DT GT1 Build Number 2132 PC 14 34 01 16 2012 02 50 10 16 01 2012 Ivy Bridge DT GT1 8086 0152 1462 2111 Rev 09 22 nm Integrated 349 MHz original 649 MHz 349 1098 MHz 350 MHz 4 1 24 v5 0 DirectX v11 1 WDDM 1 3 Intel Gen7 Copyright c 1995 2014 FinalWire Ltd Links to driver download websites are provided at the bottom of the page Desktop This page lists the desktop properties including resolution color depth font resolution refresh rate as well as the individual desktop effects 98 AIDA64 Business Page menu Multi monitor This page lists the connected monitors If there are more monitors available the primary display is indicated Monitor resolution and monitor hierarchy are also displayed Video Modes This page lists all available video resolution color depth and refresh rate options OpenGL This page provides detailed information about supported OpenGL functionality GPGPU This page provides information about the available GPGPU frameworks which enable general purpose computing on graphics processing units The GPGPU module of AIDA64 supports the latest versions of AMD Stream Microsoft Direct3D Compute Shader NVIDIA CUDA OpenCL and S3GP Links to driver download websites are provided at the bottom of th
135. ports are found in this menu AUDIT MANAGER Audit Manager can be used to compile a complete audit and audit statistics of networked computers using CSV report files or reports imported to an SQL database Page Description 2 Add report files Add report files E Add reports from database Add reports from database We can filter the information collected from our PC fleet according to several criteria and we can make quick reports of these pages File Edit Report Audit Lista List 1 HW Component Here we can have a statistical overview of the hardware components used in our networked PCs gt Refresh ps Preferences udit 19 List 1 HW Component 88 List 2 SW Component List 3 DMI Component List 2 SW Component Here we can have a statistical overview of the 23 List 4 Computer software components installed on our networked PCs E Statistics 1 Narrow m Statistics 2 Wide fll OFFICE101 List 3 DMI Component Here we can have a statistical overview of the DMI A OFFICE102 information of our networked PCs 1 OFFICE103 Ml OFFICE104 List 4 Computer This page provides a summary view of the hardware and ee software components of each PC on our network Statistics 1 Narrow Here we can see a Summary table of the whole PC fleet showing the distribution of various components in the network Using the table we can determine how uniform or heterogeneous the hardware and softwar
136. r with their properties System drivers This page lists all installed system drivers together with their properties and status Services This page lists all running and terminated processes A green icon at the beginning of each row indicates that the process is running while a red icon is displayed for processes that have been stopped It is possible to start or stop the selected process by clicking the Start Stop button on the toolbar AX Files This page lists all installed DirectShow filter plug ins codecs To view file properties double click on the file name DLL Files This page lists all installed DLL files To view file properties double click on the file name Uptime This page provides Windows uptime information and blue screen statistics Uptime statistics are based on the Windows system event log By increasing the maximum log size of the system event log we can get Statistics covering a longer period of time 96 AIDA64 Business Page menu SERVER Share This page lists the shared resources on the network folders printers We can open the shares or remove those we do not need Opened files This page lists files and folders opened locally or remotely on the computer together with the name of the user who opened them Account security This page displays information about the security settings and password policy used in the domain File View Report Remote Favorites Tools Help DUCE RM From
137. ra com Server smtp gmail com SMTP port 587 Default C Use SSL Use SMTP authentication User alertWabseira com HR Password Cancel Apply To use TLS for Gmail choose smtp gmail com as the server with the SMTP port set to 25 or 587 31 AIDA64 Business Preferences DATABASE If we store reports in a database we need to configure the database in the Preferences menu First we have to select Provider and all other settings are then dependent on the selected format We have to choose the database type we use in our system In the SQL Schema subfolder of the AIDA64 Business folder we can find 8 database schema files the ninth supported format ODBC does not require a schema file Explanation Provider and database schemas If we do not use Access SQL database table layouts need to be initialized using one of the DB files found in the SQL_ Schema folder e DB Access mdb Database file for MS Access 2000 XP 2003 2007 e DB Access97 mdb Database file for MS Access 97 e DB InterBase sql Schema for Borland InterBase and Firebird e DB MySQL saql Schema for MySQL e DB Oracle sql Schema for Oracle e DB PostgreSQL sql Schema for PostgreSQL e DB SQLServer sql Schema for MS SQL Server e DB Sybase sql Schema for Sybase Server We need to specify the name or IP address of the SQL server I
138. re elements as well The groups created here can be selected in the Monitor Remote Computers module by right clicking a blank area and selecting Remote Monitor Shortcuts We can also create command line commands as shortcuts Here we can add a description for the command and then specify the command itself One of the following control strings can be used in the command line e ADDRESS e ENDPROCESS e HOSTNAME e USERNAME The commands can be e Run on the local computer e Run on the remote computer which is always the remote computer selected in the Monitor Remote Computers module The shortcuts created here can be selected in the Monitor Remote Computers module by right clicking a blank area and navigating to the bottom of the context menu 71 AIDA64 Business Remote features REMOTE SYSTEM INFORMATION AIDA64 can provide us with detailed hardware and software information from remote computers as well If we double click on the remote computer in the Connected tab or right click on it and select Remote System Information in the context menu we will see the details of the remote machine both in the Page menu and the information window during the remote connection session By clicking the name of the Remote process we will get some basic information about the remote PC while clicking the Disconnect button on the right hand side will terminate the connection File View Report Remote Favorites Tools Help Ed UEM From
139. res to measure temperatures and cooling fan speeds via Koolance TMS 200 family sensor devices To avoid potential incompatibility issues this option is disabled by default and has only to be enabled when a Koolance TMS 200 device is connected to the system T Balancer sensor support With this option we can control whether AIDA64 uses low level features to measure temperatures via T Balancer sensor devices DIMM thermal sensor support With this option we can control whether AIDA64 uses low level features to measure temperatures of DIMM memory modules using SMBus operations To avoid potential incompatibility issues this option is disabled by default and has only to be enabled when a thermal sensor capable memory module is installed Toshiba TVALZ sensor support With this option we can control whether AIDA64 uses low level features to measure cooling fan speeds via Toshiba TVALZ sensors In rare cases polling the Toshiba TVALZ sensor device may cause system instability Volterra VT11xx sensor support With this option we can control whether AIDA64 uses low level features to measure temperature voltage and power draw via Volterra VT 11xx GPU sensor chips In rare cases polling a Volterra VT 11xx sensor chip may cause system instability while running 3D games GPU sensor support With this option we can control whether AIDA64 uses low level features to measure temperature voltage and cooling fan speeds on AMD and NVIDIA graphics cards
140. ress graphics adapters GPU This page provides detailed GPU information such as manufacturer GPU version GPU clock number of processing units fill rate memory and utilization If we have more GPUs installed in our PC we can select the one we are interested in The page is updated dynamically in real time which enables us to monitor actual clock speeds and utilization Links to driver download websites are provided at the bottom of the page File View Report Remote Favorites Tools Help ES UEM From Menu Favorites Device Description amp Integrated Intel Ivy Bridge DT Integrated Graphics Controller DT GT1 EZ AIDA6A4 b gil Computer Motherboard L Operating System J Server gt gt gt y a Me Display E Windows Video lll PCI AGP Video M2 Monitor Bi Video Modes 2 OpenGL gt a Multimedia gt Storage gt MY Network gt GP DirectX gt Ey Devices gt El Software gt ME Security gt B Config gt EY Database gt 3 Benchmark E GPU Monitor On this page we can review the monitor properties including physical information and supported video modes Field E Graphics Processor Properties B Video Adapter BE BIOS Version BE BIOS Date Bs GPU Code Name PCI Device B Process Technology E Bus Type E GPU Clock E GPU Clock Turbo BE RAMDAC Clock E Pixel Pipelines Bs TMU Per Pipeline amp Unified Shaders DirectX Hardware Sup
141. ry of INI file The information would be extracted from an INI file We need to specify the full path name for the INI file as well as the name of the INI group and the INI entry In both the text and INI file names the following control strings can be used e HOSTNAME Inserts host name e USERNAME Inserts current user name e DOMAIN Inserts current logon domain e IPADDR Inserts primary network adapter IP address aaa bbb ccc ddd e MACADDQ Inserts primary network adapter MAC address AABBCCDDEEFF e MACADDR Inserts primary network adapter MAC address separated by hyphens AA BB CC DD EE FF e UUIDMAC Inserts DMI System UUID When this is not available it inserts MAC address 00000000 00000000 0000AABB CCDDEEFF e MONTH Inserts current month MM e DATE Inserts current date YYYY MM DD e TIME Inserts current time HH MM SS Title Custom Variable 8 Registry entry Path HKEY_LOCAL_ MACHINE SOFTWARE Mozilla MaintenanceService Attented Environment variable ComSpec Line of text file WSRVR2012 text txt 1 Entry of INI file SRVR2012 Shares AIDA64 aida64 ini Generic ControlPanellcon 41 AIDA64 Business Preferences CONTENT FILTERING AIDA64 also has access to Windows event logs IE Cookies and browser history Various settings are available to filter these on the Content Filtering page in the Preferences menu These can come in very handy as usually we do not
142. s peerel DVD drives SMART information ae Metwork Network subsystem information En DirectX DirectX devices information E Devices PCI AGP PnP USB PCMCIA devices list printers information gt El Software EJ Software Software subsystem information J Security Security System security information by E Config Fal Config System configuration information gt 2 Database Database Database BDE ODBC information b JE Benchmark Benchmark Measure system performance EE jE Local Copyright c 1995 2014 FinalWire Ltd 66 AIDA64 Business Report SUBMIT REPORT TO FINALWIRE AIDA64 allows us to send reports to the developers directly from the application This can come in handy when we need support or want to report an issue or send feedback to the AIDA64 team When we select this option a quick report is automatically created using a predefined report profile that does not contain sensitive information such as license keys or information about installed software After the report has been generated we need to click Submit report to FinalWire at the top of the preview window and enter our name and e mail address and any comments we may have If we want to send anonymous reports to the AIDA64 developers we need to click the button Anonymous report submit We can include further technical details in the message if we check the Sensor Debug Embedded Ctrl and ACPI DSDT boxes To send the report we have to click OK
143. settings Software installation in the menu tree and select New Package Then we have to browse to the MSI file we want to install File Action View Help e alma E e B Bm aida64 SRVR2012 ABSEIRA LOCAL Versi Deployment st Source 4 Ae Computer Configuration 4 Policies 4 C Software Settings A Software installation pando eng fw Pg bp D Administrative Templal b Preferences 4 User Configuration Paste p Policies Refresh b Preferences Export List E There are no items to show in this view View gt Properties Help The file should be available via a UNC path in a network share with read permission Click Open then in the Deploy General Deployment Upgrades Categories Modifications Security Software window select Advanced press the OK button and eins click the Security tab Here grant read permissions to the 2 LETREHOZO TULAJDONOS A users for the installation Authenticated users have read 2 SYSTEM E perm ISS ons by d efau It i 2 Tartom nygazd k ABSEIRA Tartom nygazd k 82 V llalati rendszergazd k ABSEIRA Vallalati rendszergazd k 82 V LLALATI TARTOMANYVEZERLOK Permissions for Hiteles tett felhaszn l k For special permissions or advanced settings click Advanced Leam about access control and permissions 37 AIDA64 Business Preferences When we click OK we immed
144. shared memory The AIDA64 hardware monitoring module uses the shared memory AIDA64_SensorValues The shared memory content is a long string value ending in a 0x00 char making it a classic PChar or char The string is made of XML tags but it is not a complete XML document It includes all temperature cooling fan and voltage values AIDA64 can measure Temperatures are always in Celsius even if Fahrenheit is selected in the Preferences menu Sensor value labels are always displayed in English they are not localized The buffer size the size of the shared memory block has to be at least 10 KB A typical buffer size is around 1 to 3 KB but for Abit MicroGuru 2005 based boards for example it can be a lot more For reading the contents of the shared memory a code similar to the following Delphi procedure can be used 98 AIDA64 Business Const sharedmem_name AIDA64 SensorValues Function ExtApp SharedMem ReadBuffer bu PChar bu_size DWord Boolean Var mappedData PChar th THandle Begin Result False th OpenFileMapping FILE MAP_READ False sharedmem_name If th lt gt INVALID HANDLE VALUE Then Begin mappedData MapViewOfFile th FILE MAP_READ 0 0 If mappedData lt gt Nil Then Begin StrLCopy bu mappedData bu_size If UnmapViewOfFile mappedData Then Result True End CloseHandle th End End Here is a shared memory output example lt temp lt id TMOBO slid gt lt label
145. specify the dimensions of the SensorPanel in pixels The first value defines the width of the SensorPanel while the second value defines its height 96 AIDA64 Business 3 17 6 1 SensorPanel Manager Right clicking the SensorPanel will display the context menu from where we can open the SensorPanel Manager This allows us to add new items to the panel and modify hide duplicate or delete existing ones We can move items up or down in the list ltems are displayed as layers on the SensorPanel and this list determines the order of the layers the topmost item in the list will be the background layer the next one the first layer and so on By default an item listed under another will cover at least parts of those listed above it if they overlap each other on the panel Because of that we always have to make sure to make the background image the topmost item Description A Right click on the panel to Motherboard CPU GPU y HDD1 HDD a Corel oO Core 0 Core3 a Cored cru oF CPU Clock El Memory Clock 7 GPU Clock Type Label Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Cooling Fan System System System Preferences Duplicate Mowe Up Move Down By clicking Export we can save our customized SensorPanel to a file with the extension SENSORPANEL This file contains all graphics
146. ssary to install the Firebird Client and a Firebird ODBC driver on all networked computers For example Easysoft ODBC drivers for InterBase and Firebird can be purchased at http www easysoft com 3 7 2 MS Access 97 MS JET OLEDB 4 0 lf we use MS Access 97 we need to specify the path for the database only which is found in the SQL Schema folder We have to copy this file to a share which clients can modify and select this file We have to make sure to specify a remote path if we use a central database Here we can also specify our user name and password required for the connection Using MS Access is recommended for testing purposes only because it only allows a single computer to fully access a given Access file It is not necessary to install MS Access on the computers 3 7 3 MS Access 2000 XP 2003 MS JET OLEDB 4 0 If we use MS Access 2000 XP 2003 we need to specify the path for the database only which is found in the SQL Schema folder We have to copy this file to a share which clients can modify and select this file We have to make sure to specify a remote path if we use a central database Here we can also specify our user name and password required for the connection Using MS Access is recommended for testing purposes only because it only allows a single computer to fully access a given Access file It is not necessary to install MS Access on the computers search Database Esp Provider MS Access
147. strators as it is capable of monitoring changes in the computer network using CSV report files or SQL databases containing AIDA64 reports With only a few clicks we can easily and quickly make comparative analyses File Edit Report FP TR Duick Renar Hear Es Refresh Sf Quick Report ES Preferences User Date Date Time Event Component Full List Computer Component E OFFICE 101 4 Z Keyboard A Mouse oy Installed Programs 5 Installed Programs Ml OFFICE 102 2 JE OFFICE 103 2 Ga Disk Drive coy Disk Drive 1 OFFICE 105 10 cog ATA Device Serial Number coy ATA Device Serial Number coy ATA Device Serial Number a Internet Explorer a Disk Drive EP Primary MAC Address USE Device Share coy Disk Drive Y USE Device 102 reports Event Removed Removed Added Removed Changed Changed Changed Changed Added Changed Added Removed Removed Removed jE 19 computers Date 2014 03 17 9 52 00 2014 03 17 9 52 00 2014 03 17 9 52 00 2014 03 17 9 52 00 2014 03 18 22 38 00 2014 03 18 22 38 00 2014 03 18 9 08 00 2014 03 18 9 08 00 2014 03 18 11 50 00 2014 03 18 11 50 00 2014 03 18 11 50 00 2014 03 19 7 36 00 2014 03 19 7 36 00 2014 03 19 7 36 00 2014 03 19 7 36 00 2014 03 19 7 36 00 2014 03 20 10 58 00 2014 03 20 10 58 00 a 1 users Value Before Remote Desktop Keyboard Device Remote Desktop Mouse Device Google Chrome 33 0 1750 146 WD
148. sure to specify a file that can be accessed with write only permissions by all networked users Using a UNC path e g server share folder logfile htm is recommended Alert Methods 3H Language 7 General 4 Layout iG Stability administrator abseira com Test 4 7 Report E Report File 89 Report Look po o gt Schedule _ Send an entry to a log server e D FTP 5 Remarks _ Display an alert window J Send an e mail to Note Don t forget to configure e mail sending options on the E mail page 4 E E mail Send a Windows message to Ey SMTP EF Database ME Summary if Custom Variables Y Content Filtering g Custom Components we Asset Profile ff Remote Features E Custom Programs File Scanner a Network Alerting ot Alert Methods PE Ay Alert Triggers E Hardware Monitoring Write to a TXT log file SRVR2012 Shares AIDA64Business Alert SDATE SHOSTNAME bd _ Write to a HTML log file htm Cancel Apply 48 AIDA64 Business Preferences 3 16 2 ALERT TRIGGERS We can select those alert triggers here which we would like to use Altogether there are 14 different alert triggers available of which 4 can be customized e When virus database is older than here we can specify the number of days e When system drive free space is below here we can specify the percentage e When any local drive free space is below here we can specify the percentage e Wh
149. t Integer IOPS qs01ciops 9452GI0Ps 32 bit Integer IOPS 11 67GI0PS 9458GI0PS 64 bit Integer OPS ee 37 GOm ee 364 1 MB s 7893 MB s SHA 1 Hash 2282 MB s 1990FPs 74 23FPS Single Precision Julia Double Precision Mandel Not Supported 41 03 FPS 677 6 MB s L c 1995 20 14 FinalWire Ltd Start Benchmark Close Currently the following benchmark tests are available Memory Read Measures the bandwidth between the GPU device and the CPU effectively measuring the performance the GPU can copy data from its own device memory into the system memory It is also called Device to Host Bandwidth The CPU benchmark measures memory read bandwidth that is how Memory Write Measures the bandwidth between the CPU and the GPU device effectively measuring the performance the GPU can copy data from the system memory into its own device memory It is also called Host to Device Bandwidth The CPU benchmark measures memory write bandwidth that is how Memory Copy Measures the performance of the GPU s own device memory effectively measuring the performance the GPU can copy data from its own device memory to another place in the same device memory It is also called Device to Device Bandwidth The CPU benchmark measures memory copy bandwidth that is how fast the CPU can move data in the system memory from one place to another 1 fast the CPU can read data from the system memory 2
150. tery lt label gt lt value 23 20 lt value gt volt geyol gt lt id gt VDIMM stid gt label gt DIMM lt label gt lt value gt 1 94 lt value gt lt ol gt 99 Preferences AIDA64 Business Preferences Enable writing sensor values to Registry When we choose to share sensor values with external applications through the Windows Registry sensor values are written to the following Windows Registry path HKEY_CURRENT_USERiSoftware FinalWirelAIDA641SensorValues When AIDA64 is closed it deletes both the registry path and the values it contains from the Registry Temperatures are always in Celsius even if Fahrenheit is selected in the Preferences menu Sensor value labels are always displayed in English they are not localized Here is an example of how sensor values appear in the Registry File Edit View Favorites Help e Computer gt HKEY_CLASSES ROOT a ade HKEY_CURRENT_USER i p any AppEvents gt Mi AppABackupContentType b J Console b any Control Panel m Environment gt j EUDC gt A Keyboard Layout de Metwork b H Printers a d Software in BGadgetPack gt any AppDataLow gt J Canon gt J Classes gt A Clients gt D Dropbox gt ESET J FinalWire a AIDA64 i ing VistaSidebar gt Foxit Software gt Google gt J HeidiSQL gt D IM Providers Mame Default ab ablLabel FCPU ab Label PCPUGTC ab Label PCPUIAC ab Label PCPUPKG ab Label SBATT ab Lab
151. the value 55 AIDA64 Business Preferences 3 17 6 SENSORPANEL AIDA64 can display sensor information on a fully customizable panel called the SensorPanel which can be configured here CPU Fan 2500 Front Fan 1500 Rear Fan 1500 Show SensorPanel Here we can enable disable the SensorPanel Keep SensorPanel the topmost window When this option is enabled the SensorPanel is always visible on top of all other windows This feature is also called always on top The panel will not be visible during full screen 3D gameplay or video playback even if this option is checked Lock panel position With this option we can lock the position of the SensorPanel on the Windows Desktop Lock panel size With this option we can lock the dimensions of the SensorPanel When enabled the panel cannot be resized with the mouse pointer Enable context menu With this option we can activate the right click context menu on the SensorPanel SensorPanel Manager which provides further customization options can be launched from the context menu SensorPanel background color Here we can set the SensorPanel background color If we choose a background image that fills the entire panel the selected background color will not be visible SensorPanel transparency Here we can set the panel transparency level Window transparency level adjustment is not supported under Windows 95 98 Me and NT 4 0 SensorPanel size Here we can
152. tication and type the L a password Finally select the newly OF E mai User AIDAGA created AIDA64 database as the E pomos E Default database select the Default g Custom Variables a network folder with write permission language then set the user A AER lt BULK INSERT folder SRVR2012 Shares AIDA64Business bulk privileges on the User Mapping erste a page Here select the AIDA64 2 femelsonvel database and grant write Custom Programs File Scanner db_datawriter and read gt A Network Alerting Hardware Monitoring Cancel Apply db datareader roles to it In the Preferences window in AIDA64 Business select the Provider MS SQL Server add the server name and the authentication information or select Use Windows authentication If we have the appropriate privileges we will be able to select our newly created AIDA64 database in the Database field If we want to use the BULK INSERT function we need to add the bulkadmin role to the database on the Server Roles page in SQL Server Management Studio This can accelerate the process of inserting new records to the MS SQL Server database This feature requires a shared network folder with write permission for all users Firewall Settings If we get a warning message on the client computer Q Database connection failed notifying us that the PCs cannot connect to the server E A or there are problems with the connection we
153. tion O Z CPU3 utilization O amp CPU4 utilization Select All 57 Clear All Cancel AIDA64 Business Preferences 3 17 8 EXTERNAL APPLICATIONS AIDA64 offers the following options to share sensor readings with external applications shared memory Registry WMI Windows Management Instrumentation and Rivatuner OSD Server Search External Applications Language Enable shared memory oe eC General x 1 Layout f Stability Enable writing sensor values to WMI _ Enable writing sensor values to Registry gt Y Report _ Enable writing sensor values to Rivatuner OSD Server E mail di EF Database ba E Summary 2 w Custom Variables E F Content Filtering 2 Custom Components as Asset Profile gt AE Remote Features MI E CPU Clock fl Custom Programs B CPU Multiplier y File Scanner LIR cpu se gt A Network Alerting Y m Memory Clock 4 O Hardware Monitoring Y m Memory Speed g Update Frequency Y m DRAM FSB Ratio Q Sensor Icons Y m Memory Timings gt 8 OSD Y Z CPU Utilization gt W Desktop Gadget Y Z CPU Utilization gt MN LCD 7 Z CPUZ Utilization SensorPanel O amp CPU3 utilization Logging E External Applications a A Alerting E Correction Cancel Apply Display labels JE System Enable shared memory One of the most common ways to share information between Windows applications is
154. to choose an update frequency of at least 2 seconds 3 17 2 SENSOR ICONS Here we can activate and customize the AIDA64 sensor icons displayed on the System Tray in Windows If we enable this function the sensor icon items selected here will be displayed on the taskbar We can also customize the background and text color for each icon When sensor icons are enabled a different AIDA64 icon Is visible in the System Tray Search Sensor Icons Je FTP Y Show sensor icons iLi Remarks cor 4 F E mail L ES SMTP EY Database Value Sensor Icon E System Y GB cpu Clock BY Custom Variables E Memory Clock Wf Content Filtering Y CPU Utilization roe A Custom Components KA CPU1 Utilization BE Asset Profile C amp CPu2 utilization a Remote Features _ amp CPU3 utilization S Remote Control C amp CPUA utilization JA CPU Throttling Y BM Memory Utilization gt pg File Scanner l il Used Memory b A Network Alerting C m Free Memory a Hardware Monitoring 07 Update Frequency Da Used Swap Space i _ cg Free Swap Space E OSD E te Drive C Utilization 3 Desktop Gadget e LCD O Ga Drive D Utilization y f Temperatures E SensorPanel g Logging Ey External Applications A Alerting i Correction Y a Swap Space Utilization A io Ea LO m Select All Clear AIl o A Cancel Apply 10 06 23 41 41 41 41 41 19
155. to the manufacturers driver download websites are provided at the bottom of the page File View Report Remote Favorites Tools Help Ed UEM ro Menu Favorites ES AIDA64 gt 1 Computer b amp Motherboard gt Operating System a 3 Server A Display _ Network Adapter Description Realtek PCle GBE sorozat vez rl Field pusa EY Network Adapter Properties amp Network Adapter Realtek PCle GBE sorozatu vez rl gt a Multimedia gt amp Storage a Network amp Interface Type amp Hardware Address KY Connection Name Connection Speed Ethernet 8C 89 A5 DE 30 62 Ethernet 1000 Mbps a MTU amp DHCP Lease Obtained DHCP Lease Expires amp Bytes Received KY Bytes Sent 1500 bytes 14 07 2014 09 27 24 14 07 2014 10 27 24 2646435584 2523 8 MB 134527735 128 3 MB amp Network Adapter Addresses K IP Subnet Mask ay Gateway aY DHCP Y DNS 1 Browser History gt 3 DirectX gt gil Devices gt El Software gt M Security gt BF Config gt Database gt Ja Benchmark 192 168 1 117 255 255 255 0 192 168 1 1 192 168 1 1 192 168 1 10 y Network Adapter Manufacturer amp Company Name zw om e gt Realtek Semiconductor Corp we EP Windows Network Ni Local Copyright c 1995 2014 FinalWire Ltd PCI PnP Network This page enumerates the PCI PCI Express and PnP network controllers RAS This page provides informati
156. tory of the machines copy y server Shares AIDA64 AIDA64_template xsl TEMP AIDA64_template xsl Enable report header When this option is enabled several important information about the report creation including AIDA64 version report type computer name user name operating system type version creation date time is displayed on the top of the reports It is recommended that this option is enabled during network audit When HTML and MHTML reports are created for printing purposes we may choose to disable both report header and report footer to save paper space Enable report footer When this option is enabled a short disclaimer message appears at the end of HTML and MHTML report files Enable HTML report menu The HTML report menu is a drop down list of quick links to individual categories and subcategories which makes locating information easier in HTML reports This option is enabled by default File ld Save To File gt Send In E mail Submit To FinalWire t Preview gal Print amp Close Summary Summary Computer Motherboard Computer Name Computer Type ACPI x64 based PC Operating System DMI M Chassis CHIEFTEC CD 01 B B350 Y Power Supply CODEGEN 350W Server Overclock Operating System Microsoft Windows 8 1 Professional OS Service Pack Internet Explorer 11 0 9600 17207 Multimedia Portable Computer Display Power Management Directx DirectX 11 2 Computer Name OFFICE10
157. uct DMI System Version DMI System Serial Number DMI System UUID 4 DMI Motherboard Manufacturer A DMI Motherboard Product A DMI Motherboard Version A DMI Motherboard Serial Number 0 DMI Chassis Manufacturer J DMI Chassis Version 0 DMI Chassis Serial Number 0 DMI Chassis Asset Tag 0 DMI Chassis Type Cancel 14 AIDA64 Business File menu On the Exceptions tab we can exclude computers or General Filter Components Exceptions users from the listing so that they will not be displayed in Excluded Computers Change Manager For example if we do not want to By morriceso irs monitor the changes on all computers or for all users we a can add exceptions to the Excluded computers users lists Items on the excluded list can be modified or deleted any time Excluded Users BQ minis Modify Delete We can make quick TXT HTML MHTML XML or CSV reports of the changes displayed in the tab that is currently active re Refres S Plain Text ps Preferences 7 Comput Event Date OFFICL a IA Keyboard Removed 2014 03 17 9 52 00 Pl Mouse Removed 2014 03 17 9 52 00 15 AIDA64 Business Preferences 3 PREFERENCES The Preferences window can be opened from the File menu At the upper left corner of the window there is a search field which helps us find the options we are looking for in the tree menu The se
158. ues can be avoided by preventing the AIDA64 kernel driver from loading Low level MSR operations Here we can disable MSR instructions RDMSR and WRMSR When this option is disabled CPU FSB and CPU multiplier detection will not be provided Low level PCI bus operations With this option we can control whether AIDA64 uses low level PCI bus scanning that may cause system lockup in outdated systems typically equipped with S3 or Trident PCI video cards When this option is disabled motherboard chipset motherboard bus GPU SPD and sensor information will not be available Low level SMBus operations With this option we can control whether AIDA64 uses low level SMBus scanning that may cause system lockup in rare cases When this option is disabled SPD and sensor information will not be available 21 AIDA64 Business Preferences Low level sensor operations With this option we can control whether AIDA64 uses low level sensor scanning that may lead to system lockups or warnings or cause the CPU fan to stop in rare cases When this option is disabled no sensor information will be provided Fan divisor reconfiguration With this option we can control whether AIDA64 uses the fan divisor reconfiguration feature of the hardware monitoring module Fan divisor reconfiguration ensures that the status of all fans including low RPM fans can be detected properly However the applications MSI Core Cell and PC Alert collide with software that re
159. ui Registry Common Run C Program Files ESET ESET Endpoint S Motherboard W K ld s a z OneNote programba StartMenu User C Program Files x86 Microsoft Office b E Operating System B Skype Registry UseriRun C Program Files x86 Skype Phone Sk J Server E Wunderlist Registry User Run C Program Files x86 Wunderlist2 Wu J Display b a Multimedia gt Storage EY Network gt DirectX gt g Devices a El Software iy Scheduled Installed Programs e El Custom Programs J File Scanner bei Licenses dde File Types i Ej Desktop Gadgets gt Security gt Config gt Ef Database gt JS Benchmark mg Auto Start 7 Local Copyright c 1995 2014 FinalWire Ltd Scheduled This page lists the scheduled tasks configured in the Windows Task Scheduler Installed Programs This page lists the programs installed on the operating system Programs can be uninstalled directly from AIDA64 by double clicking them Custom Programs This page lists our custom programs and folders These can be configured in Preferences Custom Programs File Scanner With AIDA64 File Scanner we can easily find any files on our computer Unlike the integrated file search engine in Windows this module is capable of finding hidden files too File Scanner settings are available in Preferences File Scanner Licenses This page lists the product keys for certain installed software inclu
160. uter name Converter it is also possible to convert our XML reports into CSV reports Layout kE Y Show grid lines On the Filter tab we can select the time period for which General Filter Components Exceptions we would like to display the reports in Change Manager Filter By Date We can list all events or just the events from the past E few days or we can also set an interval in this case only those reports which were created in the given date List events occurred in the past days List events occurred in the following date interval interval will be used by Change Manager These settings 2013 01 01 Br 2013 12 31 Br make locating changes easier for example we can 2 ml review changes on a weekly basis as it is not practical a to view all changes from the earliest reports 17 18 19 24 25 26 31 1 2 5 6 7 8 9 C Ma 2014 07 10 On the Components tab we can further filter our reports by selecting the components we want to see in the General Filter Components Exceptions Change Manager list It is possible that the report covers joni sien M 2 Audit Components more information than required this is when selecting AZ dij HW Components Components can come in handy For example if we only de harega i 4 E DMI Components want to review changes in hardware we need to check EB DMI BIOS Vendor HW Components only M BE DMI BIOS Version E DMI System Manufacturer A pill DMI System Prod
161. want to thumb through entire event logs containing lots of irrelevant information rather we are typically interested in errors and warnings only We can configure AIDA64 to list all events or events from the last few days only If we create reports on a daily basis it is recommended to select 1 day here We can also select the kind of events we want to see in the list If we want to get rid of several pages of potentially irrelevant information we need to uncheck the List Information events and List Warning event options Search Event Logs Filtering List all events 8 List events occurred in the past days 7 El days 4 7 Report Report File C List Information events o MOTE List Warning events wf Schedule List Error events List Audit events E Datab IE Cookies and Browser History Filtering if Database E Summary e List all events i Ef Custom Variables List events occurred in the past days 4P Content Filtering y Custom Components N5 Asset Profile a a My Remote Features a es ee 5 Remote Control List http entries 7 days Al Custom Programs b gt File Scanner gt Network Alerting gt Q Hardware Monitoring Under the heading IE Cookies and Browser History Filtering we can also select a time period for which we want to see information We can also select to get file and http entries listed 42 AIDA64
162. wn in a list in the information window e Details Items with added description are shown in a list in the information window e Expand Expands all main categories in the Page menu tree e Collapse Collapses all main categories in the Page menu tree e Refresh Updates the current page 6d Report Remote Favorites Tools Help Status Bar Page Description Computer Computer description system summary lt Motherboard Motherboard processors memory chipset BIOS information Es Operating System Operating system services processes drivers information Server Server information L Display Display adapters monitors desktop information X Multimedia Multimedia devices audio and video codecs information 2 Storage Hard disks CD amp DVD drives SMART information a Network Network subsystem information 130 DirectX DirectX devices information H sl Devices A Devices PCI AGP PnP USB PCMCIA devices list printers information a El Software El Software Software subsystem information 5 J Security W Security System security information bp E Config Fal Config System configuration information b Ef Database E Database Database BDE ODBC information gt Ja Benchmark Benchmark Measure system performance gt EP Metwork gt KEP DirectX El AIDAB4 li Local Copyright e 1995 2014 FinalWire Ltd 63 AIDA64 Business Report 5 REPORT AIDA64 can makes system administration a lot easi
163. xe ACCEPT AIDA64 Business Favorites 7 FAVORITES In AIDA64 we can collect those Page menu items that we use the most often under the Favorite tab so that they can be easily accessed We can create reports of our favorite items by selecting Report Quick report on the main menu bar This menu item includes links to some useful web sites including IT news websites hardware review sites as well as BIOS and driver update solutions x File View Report Remote Tools Help i Add to Favorites Remove from Favorites d j Technology Partners d j Advanced Micro Devices IT Technology News Reviews 3 H Fintek E IT Technology News Reviews I X amp 2 Corsair e IT Rumours e Intel Corporation e Overclocking e Micro Star Int l al Firewall Mods 2 NVIDIA Corporation AE FPU Julia BEI FPU Julia S BIOS Updates E VIA Technologies E FPU Mandel El FPU Mandel E Driver Updates MEL GPU aE GPU Download fey Installed Programs Installed Progra p 7 l grams al y erm F i PAS ry subsystem read performance g Hl Memory Read ory subsystem write performance m Memory Write y EY Operating System erature voltage values cooling fans information E Sensor and printers list E Share disk health information y SMART jE Summary EP Windows Network i I CPU Hash o CPU Queen Copyright c 1995 2014 FinalWire Ltd 74 AIDA64 Business Tools 8 TOOLS In this menu we
164. yout Anytime iG Stability 4 7 Report Report File D Report Look ip FTP iLi Remarks a 7 E mail SMTP EY Database NE Summary if Custom Variables Y Content Filtering g Custom Components Asset Profile a Remote Features Remote Control jg Security fey Custom Programs y File Scanner A Network Alerting E Hardware Monitoring Once a day O Once a week Once a fortnight Once a month Store last run date in 8 Registry Machine HKEY_LOCAL_MACHINE1 Software Registry Current User HKEY_CURRENT_USER Software CATAG SHOSTNAME sys O CATAG SUSERNAME SHOSTNAME sys Custom file server share folder S HOSTNAME tag Cancel Apply 29 AIDA64 Business Preferences 3 5 4 FTP This menu page lists several options to configure the automatic FTP upload service in AIDA64 To properly configure an FTP server the following information is required FTP server address FTP port which is port 21 by default and user name and password for the connection We can also specify an FTP folder and use passive mode if required By pressing the Test button we can check the FTP server settings For anonymous login FTP password should be set to a non existing but correctly formatted e mail address for example officer company com However due to security concerns it is not recommended to use anonymous FTP upload services Currently AIDA64 does not support SFTP

Download Pdf Manuals