1. ant period for 10 minutes and then reset to normal mode after this period During this period its LED flashes every 10 seconds indicating reduced sensitivity If smoke density increases during this period i e from a fire the unit will go into alarm mode automatically If the smoke detector emits a short beep once a minute the battery is at the end of its life and requires immediate replacement Battery low voltage warning beep is indicated by at least 30 days If the red LED indicator does not flash every minute then replace the battery MTS smoke detector with wireless module operating with Elmes CB32 panel or Elmes CH8HR amp CH20R receivers indicates smoke alarm low battery warning and its presence in alarm system sabotage or and failure function Test your smoke detector regularly to ensure its working properly Push and hold the TEST SILENCE button until a loud pulsating alarm indicates its correct function Clean your MTS detector with vacuum cleaner with brush attach ment Never use cleaners water or solvents since they may damage the smoke detector Specification e Autonomous smoke alarm GARVAN MTS166 9V designed and certified to EN14604 2005 standard BSI license No KM544515 CE 13 0086 CPR 550565 e Elmes Electronic wireless module 433 92MHz lt 10mW with up to 100m operating range made to comply with 1999 5 CE directive and its relevant standards Power supply 9Vcarbon zinc battery 1 year operation alkaline o
2. ector by slow pulsing of its LED receivers or displaying OK cor rect CB32 control panel Unsuccessful learning may be due to improper learning steps or radio frequency disturb ance by other transmitters and should be repeated Deleting MTS detector in receiver control panel is done according to procedure steps described in their respective manuals Maximum number of wireless detectors learned to one re ceiver control panel is also specified in their manuals When learning MTS detector to CB32 control panel version 3 00 and up it is automatically recognized as smoke de tector and assigned to 24hour alarm line In emergency control panel displays fire alarm message along with line number and if the control panel operates with Elmes GSM monitoring module appropriate SMS messages are sent to registered phone number Older versions of CB32 panel would recognize the smoke detector as wireless PIR detec elmes elmes pl www elmes pl Elmes Electronic 07 2014 All rights reserved tor and signal intruder alarms in the line of the detector even if smoke is detected It is therefore very important to as sign a 24h alarm line type to the line zone with MTS smoke detector learned Operating wireless MTS smoke detectors with alarm system of other manufacturer requires Elmes Electronic made receiver with MTS learned output to be wire connected to 24h fire or sabotage line zone of that installation MTS smoke detectors with wir
3. eless module must be operating within safe wireless distance range to receiver control panel and must not be installed on limits of maximal operating range Prior to firm installation practical operating range tests should be conducted to ensure safe wireless connection To assess the level of radio signals received from activated MTS detector a signal level test mode should be selected in wireless CB32 control panel or dedicated Elmes RFM4 signal level indicator used when operating with Elmes receivers In the case of MTS detectors installed in distant locations Elmes TRX signal repeater use is suggested to ensure reliable operation Operating and testing your smoke alarm Operation of MTS wireless smoke detector starts as soon as battery is connected Smoke monitoring activity is indi cated by LED flashing every minute and positioned beside of TEST SILENCE button If smoke is detected the unit will emit a loud pulsing acoustic alarm 85dB at 3m distance and fast LED flashing until the air is cleared Also its wire less module emits signals to be received by Elmes CB32 control panel or receiver it is learned to to set up alarm state in fire or security monitoring system MTS detector is equipped with Hush Silence Feature activated by TEST SILENCE button If cooking or other non hazardous sources cause unwanted alarm it can be temporarily silenced by depressing the TEST SILENCE button for approximately 3 seconds The alarm will enter into a dorm
4. elmes WIRELESS PHOTOELECTRIC SMOKE DETECTOR MTS 166 9V EN electronic Detector consists of autonomous battery operated audible smoke alarm and wireless alarm mod ule transmitting smoke alarm signal to alarm control panel or dedicated receivers Detection of smoke obscuration generates loud 85dB horn alarm along with wireless alarm transmissions to corresponding Elmes CB32 wireless control panel or receiver where emergency state is further notified Operated with Elmes receivers may constitute a smoke alarm zone as part of any existing or newly designed security alarm system installation in house holds Powered by carbon zinc 9V battery the detector operates up to one year while up to three years operation may be obtained when powered by alkaline or lithium battery When operating with Elmes CB32 panel or dedicated Elmes receivers CH8HR or CH20HR the detector features monitoring of detector presence and battery voltage level After 24 hours of no test signal from the detector the receivers and the control panel indicate its absence sabotage or failure function Also low battery in the detector is indicated in the receivers and the control panel Random timing of test and alarm transmissions of the wireless module allows many MTS detectors to be installed in close vicinity The detector does not emit hazardous radiation and its operation is entirely based on photoelectric chamber obscuration by incom ing smoke The detector is intended for use in sin
5. gle occupancy dwellings only and should not be installed in public and industrial places Read this leaflet fully before MTS installation and retain for future reference Locating and installing smoke detectors Proper location of detectors is a critical factor for early smoke detection and fire alarming Prior to installation a judg ment of potential fire hazards and ways of smoke penetration is recommended When installing avoid areas where there is no air circulation e g corners of rooms For maximum protection detectors should be fitted in every room Smoke detectors should be installed in ceiling center in sleeping and living room areas as well as in ways of expected smoke distribu tion in stair ways hallways and their immediate vicinity Place detector BEDROOM at least 300mm from light fittings or decorative objects that may ob KITCHEN struct smoke entering the detector When mounting detector on side wall allow minimum 300mm free distance from ciling Installing detec tor in areas with sloping ceilings or walls keep 900mm distance from the highest point measured Do not install detector in room corners where there may not be suffi cient smoke circulation for its detection Do not fit detectors in kitchen LIVING bathroom workshop or garage where natural cooking fumes steam ROOM 0 BEDROOM dust or car exhaust fumes may trigger false alarms Suggested installation places of the MTS detectors in apartments and houses are shown
6. on side figures 1 and 2 with detector marked MTS smoke detector is battery powered device and requires no addi tional wiring Having established a mounting location remove the base part by means of squeezing two clip brackets of the detector and mark two installation holes to be drilled in ceiling or wall Insert supplied wall plugs into drilled holes and screw in the base part Now connect 9V battery to battery clip observing polarity and insert the battery into bat tery compartment at the rear of the detector Fit the detector part to the base part firmly observing different widths of clip brackets NOTE For the safety of the end user the smoke detector cannot be fitted to the base part without 9V battery installed After installation or battery replacement always test correct operation of the smoke detector by shortly pressing center positioned x TEST SILENCE button Properly functioning unit emits short loud sig Fi g 2 nals indicates LED pulsing and sends wireless transmissions Learning detector to Elmes CB32 control panel or Elmes receivers In order to operate MTS detector with Elmes made wireless module it must be learned to Elmes receiver or control panel To do so receiver or control panel must be set ready to learn transmitters according to procedure described in its operation manual followed by MTS detector activation by pressing its central placed TEST SILENCE button Re ceiver control panel confirms properly learned det
7. product end user responsibility Place amp date of product purchase confirmed by the seller ccccceeececee cece ee ee ee ee eeeeeeeeeeeeeeeeeeneeeteeaeaeas elmes elmes pl www elmes pl Elmes Electronic 07 2014 All rights reserved
8. r lithium up to 3 years operation Current consumption lt 20uA in standby and lt 50mA in alarming Operating temperatures range from 0 C to 40 Celsius Operation ambient humidity range 10 to 90 Internal horn acoustic alarm level 85dB at three meters The name GARVAN and graphic marking are property and registered trademarks of GARVAN Enterprises Ltd Hong Kong Assembled and distributed by Elmes Electronic 54 611 Wroclaw PL Avicenny 2 Str Phone 48717845961 Fax 48717845963 Limited Warranty This product is guaranteed to be free from defects in material and workmanship under normal use and service for a period of two years as from date of purchase Damage faulty use or improper handling by user or installer as well as any unauthorized changes or repairs violate manufacturer s guarantee and all due repair costs will be charged In all cases customer covers product repair delivery costs to and from manufacturer or service station Manufacturer or distributor shall not bear any liability for any personal or material injury damage or material loss result ing from its products direct indirect or partial failure to operate properly Smoke detector or smoke alarm that this detector is a part of is not a substitute of proper protection against fire or disability injury loss of life or property dam age of any kind that may occur in case of fire Appropriate fire protection measures and insurance coverage is the

Download Pdf Manuals

image

Related Search

pobierz pobierz chrome pobierz upo pobierz krs pobierz z yt pobierz google pobierz z youtube pobierz mp3 pobierz windows 11 pobierz program symfonia pobierz teams pobierz windows 10 pobierz muzyke pobierz film z yt pobierz symfonia pobierz mp3 z yt pobierz firefox pobierz z youtube mp3 pobierz brave pobierzgrepc pobierz opera gx pobierz mozilla pobierz sklep play pobierz muzyke mp3 pobierz film z youtube pobierz google chrome za darmo