Pressure Reference Type E USER MANUAL

image

Contents

1. Pressure Reference Type E USER MANUAL Digital Manometer with Max Min Display Accuracy 0 5 FS typ The Reference Type E has two operating keys The left key is to turn the instrument on and to execute its functions the functions appear successively on the display as long as the key is pressed and are executed when releasing the key The right key is used to switch between the MAX and MIN value After turn on the instrument displays the pressure range for two seconds before changing into the measuring mode The instrument has the following functions RESET Max Min value are set to the actual pressure OFF Turns off the instrument ZERO Sets a new Zero reference CONT Deactivates the automatic turn off function this function is activated with factory settings meaning the instrument automatically turns off 15 min after the last key function Notes E SIKA gegr 1901 Dr Siebert amp K hn GmbH amp Co KG 1 If the ZERO and or CONT function is activated it is indicated on the display In order to reset the Zero to factory setting and or to reactivate the automatic turn off function press the left key until ZERO and or CONT disappears 2 lf the actual pressure goes beyond the measuring range OFL overflow appears on the display SIKA Dr Siebert amp Kuhn GmbH amp Co KG Struthweg 7 9 34260 Kaufungen Germany 1 2 Tel 49 5605 803 0 Fax 49 5605 803 54 em
2. ail info SIKA net web www SIKA net i SIKA gegr 1901 Dr Siebert amp Kuhn GmbH amp Co KG Installation The Reference Type E has 7 16 UNF male thread and is delivered complete with an O ring seal swivel fitting which allows Reference Type E to be rotated through 360 Only minimal tightness is needed to seal up to 350 bar Process pressure connection is G 1 4 male process connection G1 4 Battery Change When the battery starts weakening a low battery warning BAT LOW will appear in the upper left corner of the display For battery change open the battery compartment and change the battery tyoe CR 2430 The battery life is 1400 hours in normal measuring mode Ranges Calibration The factory setting of the Zero for the range 1 40 bar is at 0 bar absolute For sealed gauge pressure measurements activate ZERO SEt at ambient pressure Instruments with the range 0 850 bar are calibrated in a sealed gauge mode with 1 bar absolute pressure as a Zero reference Digital reference test gauge Pressure medium fluids and gas media Pressure connection G1 4 male Display multi purpose LCD 30 x 30 mm Function keys SELECT reset off zero cont MIN MAX Casing 70 x 100 x 30 mm d xh x w IP65 weight approx 130 g rubber cap Power supply 3 V battery 1400 h service life continuous operation LOW BAT display AUTO Off Accuracy 0 5 FS 1 digit Measuring range Resolution Mode
3. l A 30 40 bar 0 01 bar Model B 0 300 350 bar 0 1 bar Option EEx ia IIC T5 T6 O1LATEX6001X SIKA Dr Siebert amp Kuhn GmbH amp Co KG Struthweg 7 9 34260 Kaufungen Germany 2 2 Tel 49 5605 803 0 Fax 49 5605 803 54 email info SIKA net web www SIKA net

Download Pdf Manuals

image

Related Search

Related Contents

  Optoma EP735 User Guide Manual  Page 1 Page 2 手動圧着工具取扱い説明書 手動圧着工具は小量生産  Targus 15" Vertical Slip Case  DAQFactory - LabJack Application Guide  テレビクイックガイド(303KB)    Manual de usuario de medidor multi  SPS6000 Datasheet - A-Tech Instruments Ltd.  81064102 焚火ピラミッドグリルEVO-L  

Copyright © All rights reserved.
Failed to retrieve file