PACS-5M Manual - AMD Technologies

image

Contents

1. 2 Haz 200 MC Archive BB74 Ctrl Fi2 menu Set Physicians that may access any Patient BERJE HANEY BURNER CD DAS PRANAB DATUJESUS DESAI DHIREN GABIER WENDELL PAMPATI MAHENDER PATEL ASHOK ZLAPPEN DAVID TCLIFF RATCLIFF_BASE_5TH_METATARSAL RATLIFF EDDY REDDY_FELL_AT_WORK_PAIN_THORACO Lut REDDY_HURT_BACK_LIFTING_AT_WORK REISS RHEUMATOID_ARTHRITIS RIGHT_CHEST_PAIN_DONTHINENI RIGHT_FOOT_PAIN__1_YR_ ROE za Delete Doctor Last First Show Save Set Default Add New Password Password Compression Doctor PAstart deag mib g A nbox Jon ca amp Formi R Remo TF Haz Heyg Figure 38 Select doctor and then change permissions Form 330 4 134 Rev 07 Page 29 cateLL a DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS ce IMPORTANT NOTE If an institution wants to enable a physician to see images for some but not all patients on the archive e g his patients only please call AMS for custom routing rules nal The other functions in the Gateway Administrative Mode are for AMS use only Use of these functions by systems administrators or untrained service personnel may disrupt the proper functioning of your PACS By highlighting a doctor s name and then clicking on Show Password the system will display the doctor s password This is useful where passwords have been forgotten D Image Editor From the Administrative Tasks screen of t
2. Geologie greir HIV AS Form 330 4 134 Rev 07 Page 28 J cateLLa DACS PACS 5M User Manual fliwiharee CA Affordable Upgradeable Enterprise PACS Figure 36 shows a search for patients within numbers beginning with 2 The destination window has also been opened to indicate this particular system s available options Archive Administrative Tasks TheAdministrative Tasks button in the COLELL PACS 5M Archive is used to perform two primary tasks Assigning Physicians Rights to view all images on the Archive and Editing Image files C Setting Physicians Rights to View Images Permission for a radiologist to receive images is set in the Administrative Tasks mode of the archive Accessing these functions requires a special password check with your system administrator for the current password Once the password has been entered click on the Assign Referring Physician s Rights box Set Physicians that may access any Patient d l a led Last First Save Set Default Add New Password f Password Compression Doctor Figure 37 Select Assign Referring Physicians Rights To enable a physician to see images for all patients on the archive select the appropriate physician from the List of all Physicians on the left and click on the Add box To remove a physician from the list of physicians able to see all patients select the physician from the list on the right and click on the Remove box
3. Stop Halts the automated stack viewing The RUN button changes to the STOP button once the run command is given Loop Plays the images in a continuous loop from beginning to end Figure 21 Stack Viewing Mode Sync You can move multiple series shown on the same monitor together at one time To do this engage the Sync function on the monitor WindowLevel sel Pi Window Level Source The workstation displays the stack Zoom 102 MLUERE using the window and level values found in the DICOM sa file These may differ for each image You may use the Pan Coop Window Level functions to adjust this display as you Stack Run would for any other type of image Key Images An image ina stack or any image in a series can be designated as a Key Image by pressing on the Key icon in the Stack menu This will mark the image as a key image in the Archive When querying a patient s images from the Archive the physician has the option of querying just Key Images from a series in lieu of the entire series a potentially time saving device Export This Image This allows the image to be saved as a jpg file on your hard drive under the name you give it You can then import the image in other programs such as teaching files As a default the image will be named and saved in a Key Images folder This key also appears on the main menu screen in the black Tool section Figure 22 Detail of
4. Under the DICOM standard image files are stored in a specific hierarchy DICOM Hierarchical Level Layers First Patient Second Study Third Series Fourth Image Conducting an Advanced Query Queries are conducted by layer therefore this process involves multiple steps Step 1 Click on QUERY on the Worklist Window Step 2 The Query Window will appear See Figure below The name and ID of the current patient will appear in the Query Info Name box Step 3 If you wish to query for a different patient click on the CLEAR PATIENT INFORMATION button Step 4 If you have cleared the patient information type in a name or ID number Due to the limitations of most database systems not COCCLLO PACS 5M queries will respond with close matches only Therefore it is preferable to use ID numbers Step 5 Start your query by clicking on the QUERY PATIENT LEVEL button A filled in Query Window such as that found in the figure below will appear If no information is available a oe warning message will appear in the Status area Patient 1D at the bottom right of this window While COUCLLQ PACS 5M waits for a response the status of your Query will appear Status Query Complete x 4 at the lower right side of the window a Step 6 If the Query returns items you can highlight rated bee a one or more lines with a click of the left Figure 20 Query Window returned with button lt PATIENT NA
5. Both the Generate Patient List and the Process Zipped Files Transferred In are used when reconstructing the archive ONLY AMS OR YOUR SYSTEM ADMINISTRATOR SHOULD DO EITHER OF THESE FUNCTIONS The Initialize Referring Physician List will erase the current list of referring physicians that have access to and can be sent images ONLY AMS OR YOUR SYSTEM ADMINSTRATOR SHOULD INITIATE THIS FUNCTION Form 330 4 134 Rev 07 Page 30 IcaceLL a DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS CHAPTER 12 Using the USB Back up System cateLLa PACS 5M has multiple image redundancy within its archive software using the hard drive in your PACS 5M computer However COUCLLO PACS 5M also provides a method for you to back up your image library on a removable USB that you can take offsite when it is full It is vital that you do this and COUCLLO PACS 5M is designed to automatically remind you to do so Checking the USB Back Up Access the Image Gateway screen by clicking on the Image Gateway shortcut button at the bottom of the monitor You must be logged out of the workstation to do this Enter password if your institution requires one When the removable USB drive is approximately 80 full the Image Gateway screen will change from green to yellow as a warning When it is approximately 90 full the screen changes to red for visibility It is important to remove and change the USB back up drive befor
6. gt Gateway Becueerl ition Reolized Figure 31 Destination Control Screen Another productivity and safety feature is that the COUCLLO Image Gateway automatically continues to try to resend images that have not been properly sent This allows the COUCLLO Image Gateway to continue to accumulate images for a malfunctioning device network and then automatically send them when the device network is restored It also allows the CAUCLLO Image Gateway to continue its image distribution as if the device network properly received the image on the first try thus not penalizing lower priority recipients and keeping the images flowing C Backup Images Finally but not least important the COCCLLO Image Gateway makes a copy of the image that was received from the modality This copy is made on the removable USB back up drive that allows for easy removal from the site This provides a copy of the images in event of catastrophic failure Writing a copy of the image to removable media is usually the last step in the priority scheme In this case by the time the image is written to removable media there are already copies on the modality on the CQUCLLO Image Gateway and on the recipient workstation s and or archive D Monitoring the Removable Media The cartela Image Gateway needs to be checked periodically to see if enough images have been accumulated to fill the removable USB drive The Gateway s screen is color coded to allow you to quickly
7. cartello USER MANUAL PACS 5M Version 4 0 C Released May 2009 330 4 134 Rev 07 2009 AMS IcaceLL a DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS Table of Contents CHAPTER 1 INTRODUCTION 3 Indications for Use 3 DICOM Compliant 3 System Components 3 PACS 5M Display 4 Information Network 4 DICOM Push 4 Query Retrieve of Historical Images 4 DICOM Print 5 CHAPTER 2 STARTING THE CatcLlLa PACS 5M WORKSTATION 6 Powering Up the catcLLa PACS 5M 6 Starting the CaUCLLA program 6 On Call Status 7 CHAPTER 3 PRIMARY IMAGE CONTROL TOOLS 8 Primary Image Control Tools 8 Rotate 9 Flip Image 9 Annotate Add Notes 11 Specialty Tools 11 Other Annotation Functions 12 Stitch Images 13 Image Details 13 Print Image 13 Logout 13 Quad Display 14 Overlay 14 Locator Select 14 CHAPTER 4 WORKLIST 15 Prefetch 15 Sortable Worklist 15 Select Mode 16 Cancel 16 Delete Mode 16 Query Retrieve 16 Overview of Query Levels 17 Conducting an Advanced Query 17 Moving Between Levels 17 Select Desired Images 18 OK 18 Logging Off 18 Shutting Down 18 Restarting Workstation Program 19 CHAPTER 5 MULTI FRAME IMAGES 20 Setting Display Configurations 20 Basic Image Controls Same as Others 20 Stack Viewing 20 Key Images 20 Export This Image 20 CHAPTER 6 MPR MULTI PLANAR RECONSTRUCTION 21 Screen Layout 21 Using MPR 21 Form 330 4 134 Rev 07 Page 1 A s s CateLLa Dacs PACS 5M User
8. Upgradaable Enterprise PACS Doe Tiana Dicom Tram er iho Oiii Hiie Fetimia Al Mal Paarwor Hemar obag Charmed Dki Panwewendl here Perae aaa C j Estrada Al Cneshere Daniel Liland Carol Form 330 4 134 Rev 07 Conia Siew Pirri Eaa Work Lisi Eas Enu Log Y rn aa35 ig Lae He Log Figure 46 Admin Screen Password amp Doctor Add In Log In dhmit Figure 47 Log in Screen with Multiple Doctors Step 5 Adding additional Doctors to the Log in a Open the workstation software by clicking on the Catella Icon b Select the first doctor s name and use that password to start the software c Select the Options button and then the Administrative tab to reach the screen shown in Figure 46 d To add a name enter the word admin in the password window e Now add the new doctor s name and assign a password f Repeat this procedure to list all of your doctors g When complete select the Log out button Y ou will now see that all of the doctors names are listed on the log in screen Figure 47 Page 33 l PACS 5M User Manual ZNS CateLLa DACs Affordable Upgradeable Enterprise PACS CHAPTER 14 ON CALL FUNCTION cacalas On Call feature is designed for use in networks that generally have one or more remote viewing stations either within the institution s network or connected via the internet What the On
9. ZLAPPEN DAVID CLIFF RATCLIFF_BASE_5TH_METATARSAL RATLIFF EDDY REDDY_FELL_AT_WORK_PAIN_THORACO Lut REDDY_HURT_BACK_LIFTING_AT_WORK REISS RHEUMATOID_ARTHRITIS RIGHT_CHEST_PAIN_DONTHINENI RIGHT_FOOT_PAIN__1_YR_ ROE Last First Show Save Set Default Add New Pas Ss Password Compression Doctor PAstart Aea 7 F Bi Inbox Jon Ca E Formi Fi Remo Ri Haz Hb Yt Ef Figure 49 Select doctor and then enable On Call To give a physician on call rights simply highlight the physician s name on the List of Physicians and then click the On Call button in the purple section of the screen See Figure above After an image is reviewed from a workstation by an on call doctor it will remain on the pending portion of the Diagnostic Workstation worklist See the section below called What the On Call System Does for further explanation For this reason care should be taken when reviewing on call images to avoid duplicate work Unlike other routed images the on call images are not purged from the list if another physician has already completed the diagnosis This is because the on call feature is intended primarily as a wet read option Take care to purge older images that you feel have already been interpreted by another physician e IMPORTANT NOTE If another doctor logs in as the on call doctor the first doctor will be logged out A message will display to alert the first doctor that the st
10. through a VPN for example Importing DICOM Image Files from a CD To use DICOM Importer to add image files from a CD place the CD in the PACS 5M s CD DVD drive NOT the stack in the robotic CD Recorder labeler unit and close the drive tray Open the DICOM Importer program by clicking on the DICOM Importer button on the Activity Menu Figure 25 DICOM Importer Screen Go to the screen next to the Find Images button and select the patient from the files in the CD drive and click on FIND IMAGES The system will scroll through the images found for that patient and let you know as it does so how many images remain The lead image is displayed to provide the operator with a visual cue that the correct image set has been selected Series and studies will be maintained as such Ifthe CD contains files for more than one patient you will have to check the box Include Sub Folders If nothing happens when you click on Find Images this is a good indication that the CD has images for more than one patient A list of the patients will then appear on the screen next to the Find Images button The DICOM images for each patient will be consolidated by patient Select the desired patient and proceed as above When that send is complete you may select another patient and repeat the process After the patient s images have been presented on the screen you may change the patient ID so that the imported images will be stored in your COUCLL
11. 2 Network set up not correct check subnet gateway and DNS 3 PACS not plugged into network 4 Firewall turned on 5 Bad Cat 5 Cable Imaging hitting the Image 1 Check self ini file and restart Gateway program works every Gateway but going no further time almost Image Gateway is blue 1 Verify removable USB 1s installed and powered on Can t query images from the 1 Check privileges and rights of this user archive 2 Check network cables 3 Check network addresses CD will not print 1 Check that ink cartridge is installed 2 Is cartridge out of ink 3 Is the Duet turned off 4 Is Duet plugged into the proper USB port MAY REQUIRE DRIVER RELOAD CD will not record print or both L Verify that proper media is being used Use CDR blank discs not CDRW or DVD s Duet has a red light 1 No print cartridge in tray Faulty print cartridge Form 330 4 134 Rev 07 Page 36 A s CateLLa pacs PACS 5M User Manual Affordable Upgradeable Enterprise PACS CHAPTER 16 CONTACTING US First Support Contact Your system administrator has completed extensive training in the operation of the COCCLLO PACS 5M and its software and hardware components This person is also most familiar with other aspects of your imaging network For these reasons the best place to start looking for assistance is your system administrator Second Support Contact In most areas of the world your COUCLLA PACS 5M has
12. Archive 2 TB hard drive e Image Back up removable USB hard drive e Automated System for Creation of CD with Patient Images and Self Starting Image Viewer Creates a CD with selected patient s DICOM images adds a label with information about the institution patient and CD creation date and adds a self starting image viewer at the user s option e Image Gateway Software Manages the distribution of images from the Image Archive to LAN Review Workstations if any e Review Workstation Software Includes 5 software licenses for installation on user owned PC s connected to the PACS 5M LAN network and or connected to the PACS 5M network via the Internet This software supports screen resolutions of 1280x1024 1680x1050 1440x900 and 1360x768 e Web Server Software Manages the distribution of images from the Image Archive to the CALELLA WebVue software via the Internet Optional Second Diagnostic Monitor COCCLLO PACS 5M can be configured to run with a second diagnostic monitor Form 330 4 134 Rev 07 Page 3 1 Ais CateLLa DACS Affordable Upgradeable Enterprise PACS PACS 5M User Manual PACS 5M Display CaCCLLG PACS 5M displays images in a simple direct format This is done intentionally to maximize productivity The figure below illustrates the display pee Thumbnail Column Main Image Area Move Up or Down Thumbnail Cohimn Activity Menu Qae ee Figure 2 Location of display elements on
13. Call System Does Once an image is designated on call currently by including on call in the modality s accession field the Image Gateway creates an additional destination in addition to whatever other ones it would normally use for this image This additional rule is Send this image to the Web Server to hold in its on call box The Web Server will hold this image until a radiologist logs in as the on call doctor Once a doctor is logged in as the on call doctor the system will send all images being held as on call images to that doctor s viewing station IMPORTANT NOTE How images are routed to viewing stations is set up differently for each network See your system administration for details about your system HOWEVER in most systems all diagnostic workstations receive all images IF YOU ARE USING A DIAGNOSTIC WORKSTATION AND YOU ALREADY HAVE PERMISSION TO RECEIVE ALL IMAGES THEN THERE IS NO REASON TO EVER LOG IN AS THE ON CALL PHYSICIAN In fact if you do log in as on call and previously interpreted images are pulled from the on call system these images will be considered as new and will appear on your pending list As a safety feature Catella software assumes that electing to send images multiple times is done because there is new information important for the physician to see The only time that it makes sense to check the on call box on a diagnostic workstation is if not all images are routed to that workstation AND
14. Form 330 4 134 Rev 07 Page 26 5 CateLLa DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS determine the status of the removable media When the screen is red it means that the removable media is full Even when the removable hard drive is full images will continue to be saved and stored on the hard drive Archive and not lost unless the Archive also fills E Removing Files Studies from Destination Routing To clear errors in sending images to specific destinations press the Admin Mode button and enter the password requested See Figure below The factory default password is cat03 Hazard 200 MC Gateway HGW8 Ctrl F12 menu 11 tella Gateway version 4 2 1 When in the administrative mode in the Gateway all image processing is stopped This allows the operator to work with the files that appeared at the time the administrative mode was started without having to be concerned about transient files moving in and out of the Gateway hazard 700 ME Gateway HOWE Ctrl 12 menu Mistart A Dy Bellcatetatockserver Ki Catella Gateway ver Figure 32 Password Protection Hp R23 aM Maot ODD cta Lock server cts EOFCEETI ZTE Sa E Figure 34 Picking Destinations Queues are arranged by destination in the Gateway Work can be performed on both the errors and the backed up files after picking the destination Once the files are displayed the
15. Line OK Cancel Figure 9 Length Measurement Information Box Figure10 Box with Calibrated Result horizontal or vertical Horizontal and Vertical spacing assumed equal Line Length 10 cm Measurement Method Length 1 Click on the DISTANCE button 2 Move cursor to start point 3 Press and hold left mouse button 4 Drag cursor to desired end point and release button Measurement appears on monitor Angle 1 Click on the ANGLE button 2 Move cursor to end of first leg of angle 3 Click left mouse button 4 Move cursor to the vertex of angle and click 5 Move cursor to desired end of the second leg of the angle The second leg of the angle forms as you are doing this and the angle measurement appears on the monitor 6 To set the angle click on the left mouse button again Hounsfeld Units 1 Click on HOUNSFELD UNITS button Single Point 2 Move cursor to area of interest 3 Unit values will appear in the measure box Hounsfeld Units 1 Click on HOUNSFELD UNITS button ROI 2 Move cursor to area of interest 3 Holding the left button down draw a circle or ellipse to create the Region of Interest ROI 4 The average maximum and minimum values for the ROI will appear in the measure box The figure below shows an image on a monitor with the three types of measurements il When calculating ROI values all pixels on or inside the perimeter of the circle or ellipse are used Measure
16. Manual Affordable Upgradeable Enterprise PACS CHAPTER 7 CREATING A PATIENT CD 22 Creating a CD 22 CHAPTER 8 DICOM IMPORTER 23 Importing DICOM Image Files from a CD 23 CHAPTER 9 OPTIONS 24 Administrative 24 Tools 24 Window Level Preferences 25 DICOM Transfer 25 About CaUcLLa 25 The Other Basic Buttons at the Bottom 25 CHAPTER 10 IMAGE GATEWAY OPERATING INSTRUCTIONS 26 CatcLLa Image Gateway 26 A Receive Images 26 B Distribute Images 26 C Backup Images 26 D Monitoring the Removable Media 26 E Removing Files Studies from Destination Routing 27 CHAPTER 11 ARCHIVE OPERATING INSTRUCTIONS 28 A Hard Drive Archive 28 B Image Push 28 C Setting Physicians Rights to View Images 29 D Image Editor 30 E Other Administrative Tasks 30 CHAPTER 12 USING THE USB BACK UP SYSTEM 31 CHAPTER 13 INSTALLING LAN WEB LICENSES ON REMOTE PC S 32 CHAPTER 14 ON CALL FUNCTION 34 What the On Call System Does 34 Physicians and On Call Images 34 Setting Physicians Rights to Receive On Call Images 34 CHAPTER 15 TROUBLESHOOTING GUIDE 36 CHAPTER 16 CONTACTING US 3 CHAPTER 17 IMPORTANT NOTES 38 CHAPTER 18 LICENSE AGREEMENTS 39 Form 330 4 134 Rev 07 Page 2 Ais cateLLa DACS Affordable Upgradeable Enterprise PACS PACS 5M User Manual CHAPTER 1 INTRODUCTION Indications for Use The Catella PACS 5M is a medical image and information managemen
17. Profile While logged into the Standard Doctor add new doctors This will give each doctor the same institution wide settings The Administrator can also reset the Worklist and the Error Log Tools Window Level Preferences About Catella aministrat Dicom Transfer Name Demo Daniel Administrative Password Old Password New p Password Confirm New Password E New Doctor settings copied from this Doctor Log in under new Doctor to change those settings OK Log Out Figure 26 Administrative Tab This tab also allows you to change the entry password for the current user To change a password enter the old password and then the new password Tools Administrative Dicom Transfer Tools Window Level Preferences About Catella Default Tool Measurement Units Window Level Canit C Zoom Millimeters Muti Frame Images C Display Text Overlay No Text Overlay Orientation Markers c On Off Log Out Figure 27 Tools Tab Using these options each user can customize the way they use CQUCLLO PACS 5M Default Tool Each user can select the default tool that comes up when they begin each patient Pan is not an option because images never initially appear larger than can be seen on one monitor Multi Frame Images Choose the default setting to display or not display text overlay Orientation Markers Choose to display or not to disp
18. Software Product except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation Except as noted above the Software Product is licensed as a single product Its component parts may not be separated for use on more than one computer You may permanently transfer all of your rights under this license only as part of a sale or transfer of the Digital Workstation provided you retain no copies you transfer all of the Software Product including all component parts the media and printed materials any upgrades and a copy of this agreement and the recipient agrees to the terms of this agreement If the Software Product is an upgrade any transfer must include all prior versions of the Software Product Precautions And Permitted Uses The Product may be used only for the intended uses specified in the user manual of the Product The Product may be used only by trained personnel who are qualified licensed and experienced in conducting the relevant medical procedures The Product may be used only after thorough review of and strictly in accordance with the user manual of the Product All results provided by the Product must be clinically verified and checked before patient treatment The Product is an evaluation tool intended to provide aid and support to trained personnel and should not be used as a decision making tool Life Support Procedures And High Risk Activities You acknowledge that
19. a COUCLI_G PACS 5M Monitor Main Image Area All images are initially presented in the correct aspect ratio and are enlarged to take advantage of as much of the monitor as possible in this area Activity Menu All controls for the workstation are located here this is the default location This horizontal area at the bottom of the screen is divided into four general areas From left to right Window Level Controls Stack controls Advanced Tools and Image Information Image Information includes such items as patient name patient ID number image date and time Your system administrator can modify the data displayed in this box Thumbnail Column The first image in each of the current patient s series is displayed vertically in this column This allows you to quickly understand the number of image sets needing review By clicking on one of these images that image set will be displayed in the Main Image Area If more series are available than can be displayed in this vertical area controls are provided to move up and down the column Information Network CaCCLLG PACS 5M provides communications capability to receive display store and print patient images from a modality cateLLa PACS 5M operates over an Ethernet network 10 100 1000Mbps The operation of CQUCLLO PACS 5M is independent of the underlying communications technology Connections between the CQUCLLO PACS 5M Workstation COUCLLO Scan and other network equipment are regulated thr
20. confirm the instruction If you say Yes all annotations will be deleted for that image Compression and Write Resolution You can modify the resolution and the compression factors used in saving images to your reports The write resolution window indicates whether bits are to be skipped in the saving process Compression makes the image file size smaller but it is lossy compression meaning that image information is lost You can try various settings to determine your preference for the output quality you need for your referring physician reports and output files Remember these resolution and compression selections do not affect the images saved on the archive only the images used in your reports and images saved to files for other non diagnostic work Save If this button is pressed the screen with annotations will be saved as an overlay to the original image in the Archive When the patient s images are retrieved from the Archived the overlay will be there It can be clicked on or off as desired using the Overlay button in the Activity Menu Export This Image This allows the image to be saved as a jpg file on your hard drive under the name you give it You can then import the image in other programs such as teaching files As a default the image will be named and saved in a Key Images folder This key also appears on the main screen in the black Tool section Close To exit the Annotation menu press Close Form 33
21. equipment has resulted from accident abuse or misapplication which shall include the unauthorized loading of other vendors software on any equipment running the Software Product the use of the equipment for internet activity unconnected to the use of the Software Product and or the failure to maintain current anti virus software on the equipment Any replacement of the Software Product or equipment will be warranted for the remainder of the original warranty period or thirty 30 days whichever is longer Copyright 1998 2009 by American Medical Sales Inc All rights reserved American Medical Sales AMS CaUCLLa CatclLlLa PACS catelLlLa Scan catea Scribe CQUCLLO Image Gateway CaUCLLO Image Armor CaQUCLLA Image Relay COUCLLOA Floating Menu CaUCLLO Audio Attendant CAaCCLLA CD Burner COUCLLG PACS IM CaQUCLLA ImageVault cateLlLa MammoVue CatcLlLa MIDAS Server CaUCLLA Web Server CaUCLLa Teleradiology CacteLLa PACS in a BOX catella Micro PACS CatCcLLa PACSVUE CatcLlLa PACS 3M and CatCCLLG PACS 5M are trademarks of American Medical Sales Inc All other trademarks tradenames products or services are registered trademarks of their respective companies Form 330 4 134 Rev 07 Page 40
22. first image of the first four series will be loaded into each area The active quadrant will be outlined in red To designate a quadrant as active move the cursor into the quadrant and left click This new quadrant will now be outlined in red Also note that for studies that include scout images the scout image for each series appears in the lower right corner of each frame with locator lines nal When the Quad Display is activated the button label resets to SINGLE IMAGE Press this button to deactivate Quad Display Overlay Text Overlay allows the doctor to see some of the modality s settings i e mag strength slice thickness etc Locator Select Allows the user to manually select a more relevant image to use as the scout image To select a new scout click on LOCATOR A selection of new possible scout images along with relevant DICOM data will appear along the top edge of the monitor To select a new scout simply click on one of the images Form 330 4 134 Rev 07 PACS 5M User Manual X mn FA Figure 16 Quad Display thee m be pex penama as e ax lt 0 siun omiaa ome enter hee bosgan Sam emengrien amine mannas pear eres rus i reat ont te en Figure 17 Locator Selection Page 14 Ais cateLLa PACS Affordable Upgradeable Enterprise PACS PACS 5M User Manual CHAPTER 4 WORKLIST The worklist displays the names of patients whose images are pending
23. more manageable improves the processing speed of the Workstation and eliminates the need for administrators to manually delete diagnosed patients from the active Worklist ce Under normal circumstances end your session with the Log Out command Logging Off The Logout command can be selected from a number of different locations These include the Activity Menu the Worklist window and the Options window The Logout Command ends the reading session returns the workstation to the CAUCLLGO PACS 5M logon screens but keeps the workstation ready for another log in ce CaUCCLLGOPACS 5M should always be left on and not shut down This will allow the workstation to receive incoming images and to process them If the COUCLLOPACS 5M is shut down images will be received only when it is turned back on The accumulated images that should have been sent to the workstation may take significant time to load and process Shutting Down The Quit command can be selected from the Doctor Log In window This will close the Workstation program but it will leave the Archive Gateway and other programs running Form 330 4 134 Rev 07 Page 18 A S CateLLa Dacs Affordable Upgradeable Enterprise PACS PACS 5M User Manual Restarting Workstation Program To restart the Workstation program after closing it with the Quit command click on the CQUCLLO Workstation shortcut icon on the Desktop The Doctor s Login Screen will appear and you may begin an
24. you are the on call physician In this case you will get all your normally routed images AS WELL AS those marked for the on call physician Physicians and On Call Images Radiologists who have been set up with the permission to receive on call images will see an on call checkbox on their log in screen see Figure below To receive on call images a physician places a check mark in the on call checkbox and then logs in using his her password The on call selection box must be checked before the OK box is clicked during the doctor logon Once the physician has logged in as the on call physician all on call images that have not been delivered to the previously on call physician will be automatically sent Enter Password Shutdown Figure 48 Selecting On Call from Catella Workstations Physicians who have not been set up with permissions to be an on call physician will not see the On Call check box on their log in screen See the next section for the how permission is set up Setting Physicians Rights to Receive On Call Images Permission for a radiologist to receive on call images is set in the Administrative Tasks mode of the archive To get the Administrative Tasks follow the directions in this chapter until you have activated the Assign Physician Rights Screen Form 330 4 134 Rev 07 Page 34 PACS 5M User Manual 2 Haz 200 MC Archive BB74 Ctrl F12 menu O x BERJE HANEY BURNER CD
25. 0 4 134 Rev 07 Page 12 AS cateLL a DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS Stitch Images Stitch Images is a feature that allows you to combine two images together for situations where a larger field of view is needed This is especially useful in orthopedic environments where long leg or scoliosis views are required If your workstation contains our optional stitching software there will be a Stitch Images button in the Activity Menu When viewing an image that you wish to combine with another image in the same series press the Stitch Images button The workstation will display the series of images at the top of the screen Figure 13 Images Available for Stitching You will be directed to Click on Image 1 Select an image with the cursor That image will disappear from the image lineup You will be directed to Pick 2 Image When you select the remaining image to be stitched you will be directed to Right and Left Click to Move Images The two selected images will appear on the screen as in the figure below and can be dragged into position vis a vis each other using the cursor When you select Stitch the two images will be stitched into one and the screen will return to the series you were viewing before After you go to the worklist and recall the patient the stitched image will appear in the thumbnail column as a new image in the series Image Details cateLLa PAC
26. 330 4 134 Rev 07 Page 6 AL cacera DACS PACS 5M User Manual Hawar CA kasa Affordable Upgradeable Enterprise PACS W catceLLa DACS Affordable Upgradeable Enterprise PACS Doctor Test Version 4492 Log In Quit Figure 4 Doctors Log in Box A second password screen will now appear Type your password and press OK Enter Password OK Log Out Figure 5 Password Box Your patient s first images will immediately appear and you can begin your interpretative work On Call Status This is an option usable when the system is connected to multiple viewing stations See Chapter 14 for details Form 330 4 134 Rev 07 Page 7 i J cateLL a DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS CHAPTER 3 PRIMARY IMAGE CONTROL TOOLS All COUCLLO PACS 5M image controls may be accessed through the Activity Menu The most commonly used controls ZOOM PAN WINDOW LEVEL may also be accessed using your trackball or mouse buttons Primary Image Control Tools When you login to COUCLLG PACS 5M the primary tool will be set to window level To change the tool to zoom or pan click on the right mouse button or press the button to the left of the desired tool s name in the activity menu The screen cursor will indicate which control function is currently active See the figure below for icon definitions W 4 Figure 6 Window Level Pan and Zoom Icons Cont
27. Distance C Angle Hounsfeld Units Average 269 64 Max 331 Min 196 Figure 11 Views of Measurement Windows Showing Distance Angle and Hounsfeld Units ROI Many measurements can be made on an image Form 330 4 134 Rev 07 Page 10 7N CateLLa Pacs Affordable Upgradeable Enterprise PACS PACS 5M User Manual r When using a color monitor each type of measurement is displayed using a different color Distance blue Angle yellow Hounsfeld Units red di You can make many measurements on an image Each set of measurements will appear in a different color up to 10 colors before the colors begin to repeat Add Notes catel a PACS 5 M also allows the physician to add permanent notes to a patient file directly on an image Upon pressing ADD NOTES a two part Image Notes dialog box will appear Saved Notes on top and New Notes below The physician can add notes in the lower box and upon clicking SAVE NOTES the notes will be added permanently to the image file as an overlay together with the name of the login doctor making the entry and the date and time the notes were made The notes and identifying information and time will move to the saved notes portion of the dialog box By clicking HIDE the box will disappear from the screen allowing full image viewing Once notes have been added to an image file the button on the main menu will say READ NOTES instead of ADD NOTES To recall notes previously made simpl
28. ENT PURCHASED FROM AMERICAN MEDICAL SALES INC In all cases American Medical Sales Inc shall not be liable for any failure to perform its obligations under this Agreement because of circumstances beyond the control of American Medical Sales Inc which circumstances shall include without limitation natural disaster or Acts of God including lightning strikes terrorism labor disputes war declarations of governments transportation delays failure of your Computer System or other hardware or systems electrical satellite or other telecommunications failure and or misuse of the Software Product or Documentation by you Any claims by you under this Agreement must be brought within one year of the date on which you became aware or should have become aware of the facts giving rise to such claim Failure to bring such claims within the specified period shall constitute an irrevocable waiver of your rights as regards such claims under this Agreement or otherwise American Medical Sales Inc s entire liability and your exclusive remedy shall be at American Medical Sales Inc s option either a return of the price paid to American Medical Sales Inc for the Software Product and associated equipment or b repair or replacement of the Software Product or hardware that does not meet this Limited Warranty and which is returned to American Medical Sales Inc with a copy of your receipt This Limited Warranty is void if failure of the Software Product or
29. IZED PURPOSES INCLUDING BUT NOT LIMITED TO EMAIL OR OTHER COMMUNICATIONS MUSIC OR VIDEO DOWNLOADS OR PLAYING OR GENERAL USE OF THE INTERNET Make sure the Removable Backup Drive is plugged into one of the USB ports on the computer Once the computer is on the COUCLLO Workstation Image Gateway Image Archive and Web Server programs will power up into the Windows XP Pro operating system This may take several minutes Once Windows XP Pro is running you may be asked to provide a password to turn on the computer depending upon your institution s requirements Minimize the Catella Gateway Catella Archive and Catella Web Server programs Starting the catelLLa program CatCCLLG PACS 5M offers two levels of security Passwords are required to power up the CQUCLLO Workstation and again to verify a reading doctor s identity when that doctor logs into a session Once the correct password has been entered a blank screen will appear on each monitor If other Catella program screens appear minimize them The screen will also have the traditional Windows Start button and the COUCCLLOG Workstation Icon The Windows Start button can be used to access other programs and to shut down the workstation Catella Workstation Figure 3 COCCLLO Workstation Icon To activate the diagnostic reading software CLICK on the COUCLLO Workstation icon The doctor s log in list will appear Highlight your name and CLICK on the LOG IN button Form
30. ME gt Click on GET Patient Level Information SELECTED IM AGES to begin the retrieval process This patient s image files will appear at the end of your worklist when they have transferred to the COCCLLG PACS 5M monitor To remove the highlighted status click on the name again Moving Between Levels cateLLla PACS S5M provides a productive method for moving up or down the DICOM storage hierarchy The QUERY button lower left changes its second line descriptor to describe the next lower level It starts with Form 330 4 134 Rev 07 Page 17 EMS CateLLa DACs PACS 5M User Manual Affordable Upgradeable Enterprise PACS Patient Level changes to Study Level then to Series Level and finally to Image Level To move down to the next image level click on this first QUERY button To move up a level click on the UP QUERY LEVEL button Select Desired Images Now that you have determined the level you wish to retrieve from pulling the images to your worklist is simple Click to highlight the line that represents the image s you wish to retrieve You can retrieve more than one item by highlighting as many lines as desired See example in Step 6 above You must select at least one item before using the GET SELECTED IMAGES Command To exit the Query Window click on the EXIT button By selecting Key Images Only only images that have been designated as key images from a particular series will be retur
31. O Archive in conformance with your institution s numbering standards Next select the destination s to send the images and press the SEND button The destination choices will have been set up by your administrator or AMS during installation and normally include the COUCLLO Archive and the CQUCLLO Workstation If the send is interrupted or otherwise fails the system will automatically retry it When you log in to your CQUCLLG PACS 5M and check the pending worklist the imported images will be there under the patient name and corrected ID together with all of their DICOM information if the Workstation was a selected destination If the images were sent to an Archive they can be also be reviewed by querying the Archive Form 330 4 134 Rev 07 Page 23 PACS 5M User Manual Ais CateLLa PACS Affordable Upgradeable Enterprise PACS CHAPTER 9 OPTIONS This area should only be used by the system administrator to add users and to set preferences for these users Administrative Adding and removing a user is a system administration function A special tab is provided for this work and a special password is required When a new user name is added and confirmed all settings of the current user are copied to the new user s profile When a password is entered COCCLLO PACS 5M automatically and without notice to the user logs out the old user You can now reenter under the new user name nal Setup Hint Set up a Standard Doctor
32. S 5M allows you display the DICOM header information For readers familiar with the individual entries in these records a vast amount of detailed information about how the image was captured and in some cases patient information can be found The figure to the right shows one page of the image detail file Figure 15 Example of Display of Image Details Print Image cateLLa PACS 5M allows you to automatically burn the images for a patient to a CD and create a label with the patient s identifying information and add viewing software at the user s option so that the CD will self play when inserted into most Windows based PC s See Chapter 7 for details Logout Logout allows you to end your reading session This will take you back to the doctor login screen and signals COCCLLO PACS 5M that you are no longer actively reading images Where the CQUCLLO PACS 5M can be accessed by more than one doctor this is an important safety step to prevent misreporting of the reading physician Further HIPAA requirements may make this necessary depending on physical access to the workstation Form 330 4 134 Rev 07 Page 13 a Ais cateLLa DACS Affordable Upgradeable Enterprise PACS Quad Display cateLla PACS 5M allows you to easily reconfigure the layout to display multiple series on one screen Simply click on the Quad Display button The Main Image Area will automatically divide into four equal viewing areas The
33. S SUPPLIERS DO NOT AND CANNOT WARRANT THE PERFORMANCE OR RESULTS YOU MAY OBTAIN BY USING THE PRODUCT OR DOCUMENTATION EXCEPT AS EXPRESSLY SET FORTH ABOVE AS A LIMITED WARRANTY AND EXCEPT FOR ANY WARRANTY CONDITION REPRESENTATION OR TERM TO THE EXTENT TO WHICH THE SAME CANNOT OR MAY NOT BE EXCLUDED OR LIMITED BY LAW APPLICABLE TO YOU IN YOUR JURISDICTION AMERICAN MEDICAL SALES INC AND ITS SUPPLIERS HEREBY EXPRESSLY DISCLAIM ANY AND ALL WARRANTIES CONDITIONS REPRESENTATIONS GUARANTEES OR TERMS EXPRESS OR IMPLIED WHETHER BY STATUTE COMMON LAW CUSTOM USAGE OR OTHERWISE AS TO ANY MATTER INCLUDING WITHOUT LIMITATION THE WARRANTIES OF MERCHANTABILITY INTEGRATION SATISFACTORY QUALITY OR FITNESS FOR ANY PARTICULAR PURPOSE Limitation of Damages IN NO EVENT WILL AMERICAN MEDICAL SALES INC OR ITS SUPPLIERS BE LIABLE TO YOU FOR ANY DAMAGES CLAIMS OR COSTS WHATSOEVER OR ANY CONSEQUENTIAL INDIRECT INCIDENTAL DAMAGES OR ANY LOST PROFITS OR LOST SAVINGS EVEN IF A REPRESENTATIVE OF AMERICAN MEDICAL SALES INC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSS DAMAGES CLAIMS OR COSTS OR FOR ANY CLAIM BY ANY THIRD PARTY THE FOREGOING LIMITATIONS AND EXCLUSIONS APPLY TO THE EXTENT PERMITTED BY APPLICABLE LAW IN YOUR JURISDICTION AMERICAN MEDICAL SALES AGGREGATE LIABILITY AND THAT OF ITS SUPPLIERS UNDER OR IN CONNECTION WITH THIS AGREEMENT SHALL BE LIMITED TO THE PRICE PAID TO AMERICAN MEDICAL SALES INC FOR THE SOFTWARE PRODUCT AND OR EQUIPM
34. Stack Controls Form 330 4 134 Rev 07 Page 20 a Ais CateLLa pacs Affordable Upgradeable Enterprise PACS PACS 5M User Manual CHAPTER 6 MPR Multi Planar Reconstruction Multiplanar Reconstruction MPR is a post processing technique that reconstructs the axial images into coronal and sagittal anatomical planes MPR is an extra cost option on the COCCLLO PACS 5M CaUCLLG PACS 5M s MPR program allows the user to Scroll through the series in the axial coronal or sagittal image planes e Utilize 2D measurement tools like length angle Hounsfeld units e Complete annotation Screen Layout Here is an MPR screen layout Note that each view is appropriately labeled axial coronal or sagittal Using MPR To use MPR move the cursor to any one of the images Once over the image the cursor changes to a set of cross hairs When the left trackball button is pressed the center of the cross hairs becomes the point of the cursor As you move the cursor in any direction the other images shift to show you the reconstructed images for that point Moving the cursor to one of the other images changes the reconstruction control to that new image Keep in mind that CaCCLLG PACS 5M only displays actual data points It does not interpolate information Therefore the best reconstructed images will be attained using CT or MR series with a large number of image slices spaced evenly and closely together If a s
35. ace Free 27 379 Megabyt ego es xrays or 446 071 MRI images Logout You can also request the system to prefetch studies by modality type e g the last four ultrasound studies See your system administrator for details Sortable Worklist When a case is diagnosed by clicking on OK the patient s name will move from the Pending Patients Worklist to the Completed Patients Worklist You may view images from the Completed Patients Worklist as well After a few days patients names will be automatically moved from the Completed Patients Worklist to the COUCCLLG PACS S5M archive This allows fast access to recent images and keeps the information on the worklists manageable COUCLLG PACS 5M s straightforward worklist design has a purpose It increases your productivity Keep in mind that the more information displayed the more time you will spend reviewing it Limit worklist information to the bare minimum necessary Remember that you can always bring up DICOM Image Details if you need more information your You may also sort the worklist You can sort by any of the columns shown As with other Windows style programs click on a column heading to sort in ascending order Click a second time to change the sort to descending order The VIEW option allows you to select to see pending or completed studies The COLUMNS option allows you to select columns to be displayed for the two different types of studies The di
36. adeable Enterprise PACS PACS 5M User Manual E Digams Notepad File Edit Format View Help New Installation informaiton l2 this computer s unique number seed Pict Waren T lt Number of screens sipe 1280 gt pixel width of single screen Rs 1024 pixel height of one screen Last Nana 1 days autodelete age cutoff number fol lowe 1 days Local archive for x days MOME no Password 9650123478 Key Nuenbear Admin Archive IP 800 number of seconds with Echo test pend MONE Host Name for RIS system for Reports Ok Shutdoen MONE RIS Server CHL f Port Figure 44 Location of serial number BASU Ee cr Phe yannstla Non eres Step4 Set up the Doctor s Log in 1 Click on the Catella icon again The Figure 45 screen will display This screen only displays the first time you start the program after entering a serial number 2 To register the first doctor enter a last name a first name and a unique password to be used for that doctor 3 AMS will give you a list of unique key numbers when you register your license use 1 if this workstation is not connected to a larger PACS system 4 Enter self as the Archive IP if this workstation is not connected to a larger PACS system If it is connected to a PACS use the IP address of the Catella Archive This will tell this workstation where to go when sending a query request 5 End the install by clicking the OK button Affordable
37. ads to Displiy About Catella ae Patient Sex M Study Date Time Institution Name Veterinary Dicom Fields receive engine and to test connectivity to the Scribe 7 Patient Birthdate Image DateTime Referring Physician Species e x r Sindy POTR Breed or other system Contact your system administrator 7 PAs ae Bee ii e Patient Location prior to using this tab Font Size Reset DICOM SEE Engine OK Log Out Figure 29 DICOM Transfer Tab About catea Administrative Dicom Transfer This tab contains important notes regarding the software and its use and sets forth the End User License Agreement and other related information Tools Window Level Preferences About Catella Catella c American Medical Sales Inc 1998 2003 800 423 3535 version 4 2 8 All rights reserved IMPORTANT NOTES The Other Basic Buttons at the Bottom Catella Diagnostic Workstations display pre recorded and previously stored digitized images patient information and associated data using COMPA ms and higt adical grade monitors supplied with the workstation and databases available from the user s facility The s de is to allow health care professionals to view the electronically available images and other patient information for treatment plannang OK Closes the Options Window Catella Review Workstations and Catella WebVue vieu dic da monitors to dis
38. atus has changed This is done because 1 most physicians follow rotating schedules that will not overlap and 2 as an image management safeguard in case the first doctor forgets to log out when his her rotation has ended In the event that this transition takes place while images are flowing some of the patient s images will be on the first doctor s system and some will be on the second doctor s system This normally will not be a problem since doctors who are not on call will probably not be logged in to the system and will not have checked their on call box nal IMPORTANT NOTE Logging out cancels that doctors on call status WHEN A PHYSICIAN S ON CALL ROTATION ENDS THE DOCTOR SHOULD MAKE SURE THAT ALL NEW IMAGES HAVE ALL BEEN RECEIVED AND THEN LOG OUT OF THE SYSTEM SO THAT NO IMAGES WILL BE SENT TO HIM HER Once images are delivered to an on call doctor they will be erased from the Web Server As stated above these images will still be in their other destinations 1 e diagnostic workstations or archive for later use Form 330 4 134 Rev 07 Page 35 cateLL a DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS CHAPTER 15 TROUBLESHOOTING GUIDE Commonly Asked Service Questions and Their Answers No image on monitor L Check monitor cable digital cables are touchy 2A Turn monitor on amp off to check for signal 3 Reboot system PACS not receiving images L Modality not configured properly
39. been sold to your facility through an equipment retailer These medical imaging specialists have been thoroughly trained on the CQUCLLO PACS 5M They will be particularly helpful in handling the hardware aspects of your system See your system administrator for their contact information Third Support Contact Please contact American Medical Sales for support that cannot be provided from either your system administrator or your local CQUCLLO PACS S5M reseller How to Contact Us Mailing Address American Medical Sales Inc 13105 S Crenshaw Blvd Hawthorne CA 90250 U S A E Mail catella_support digitalams com Please note that e mail support is only available during normal business hours American Medical Sales Inc business hours are 7 00AM to 5 00PM Pacific Standard Time Monday through Friday E mail is checked several times each day by our support personnel This method of inquiry should be used for more in depth questions that are not time sensitive Fax Number 310 219 3201 Telephone Number 310 219 3200 American Medical Sales uses an advanced voice mail system to support your needs If a support operator is not available please listen to the message carefully Messages for non urgent inquiries should be left and will be answered as quickly as possible If your inquiry is urgent and an operator does not answer your call listen to the message to activate our emergency response system Form 330 4 134 Rev 07 Page 37 A S efejaa eno
40. c unit and let it run through its self test 2 then turn on the Duet CD recorder labeler and let its lights stabilize and finally 3 turn on the PACS 5M computer and monitor IT IS HIGHLY RECOMMENDED THAT THE CATELLA PACS 5M BE PLUGGED INTO A UNIVERSAL POWER SUPPLY UPS SO THAT BATTERY POWER IS AVAILABLE TO PROPERLY SHUT DOWN THE WORKSTATION IN CASE OF A GENERAL POWER FAILURE IN YOUR FACILITY THE UPS WILL ALSO HELP ASSURE A CLEANER SOURCE OF POWER FOR THE WORKSTATION WARRANTIES AND SERVICE PLANS ON catcLLa PACS 5M EQUIPMENT AND SOFTWARE DO NOT COVER DATA LOSS OR CORRUPTION OR CLAIMS LIABILITIES DAMAGES COSTS AND EXPENSES RELATING THERETO INCLUDING CHARGES FOR RECOVERY OR ATTEMPTED RECOVERY OF DATA WHETHER SUCH LOSSES ARE CAUSED BY POWER SURGES VIRUSES IMPROPER HANDLING OR FAILURE OF EQUIPMENT AND HARD DRIVES OR ANY OTHER CAUSE NOR DO catclLlLa PACS 5M WARRANTIES AND SERVICE PLANS COVER DAMAGE TO EQUIPMENT AND SOFTWARE CAUSED BY POWER SURGES VIRUSES OR IMPROPER HANDLING OF EQUIPMENT AND HARD DRIVES A UPS WILL HELP PROTECT YOUR INVESTMENT cate_La PACS 5M IS A FDA LISTED MEDICAL DEVICE DO NOT ADD TO OR CHANGE ANY SOFTWARE OR CONFIGURATION SETTINGS WITHOUT THE PRIOR EXPRESS WRITTEN APPROVAL OF AMERICAN MEDICAL SALES INC ANY CHANGES MADE TO THE SYSTEM MAY VOID YOUR WARRANTY OR SERVICE MAINTENANCE AGREEMENT COVERAGE T cate_La PACS 5M WARRANTIES AND SERVICE PLANS MAY BE VOIDED BY IMPROPER USE OF THE EQUIPMENT FOR NON AUTHOR
41. chnician 2 AMS will direct you to the screen in Figure 43 and walk you through the steps to install the serial number license code as outlined in e Sewes nsee older x hanes we Ta step 3 B a El dorePretContig IEE Text Document 4 Hea ti nny Gaii Heri TUTE feck Capture fe Defa Prinber Hodialty Conf LE Text Douman Improper Senal Number E roe ISDE Test Document p x P n Ea cred T iE GUT Fie Call Amencan Medical Sales and give them peat LKB Text Document System Number 004230310 ie NADERA Enter number they give you below UEA COCOH Tn Jgs 100 area sae wanes w r O DOM Ih_lnages yu f D GOA n mapras J E i 1R af Dt urresrat Ey Diet atin Emor bsg Fase T 2 Diewtion Pendre T Etre ALONE JEE ORD Fin 29 In Saray 10040 aia bri _ A LER ovri C fs taeda a Eros fe Pre LES PRE File Figure 42 Serial Number Screen Figure 43 Location of Digams file Step 3 Installing License Code Open your Windows Explore program Navigate to C AMS Cat4DataElements Figure 43 Select and open the file digams txt on some computers you will not see the txt This file will open in a text editor Figure 44 Look seven lines down You will see what appears to be a license code similar to one given to you by the AMS service group Replace the number in the file with the number given to you Save the file and close Explore sca cae age Form 330 4 134 Rev 07 Page 32 Alami a r Ais CateLLa DACS Affordable Upgr
42. corporated in the Software Product the accompanying printed materials and any copies of the Software Product are owned by American Medical Sales Inc or its suppliers You may not copy the printed materials accompanying the Software Product The software referred to in general as Catella may include enabling software from other sources such as Microsoft Mallinckrodt Institute of Radiology University of Oldenberg Orthocrat Ltd CompuMed Inc Calgary Scientific Inc and Accusoft Corporation whose licenses rights and restrictions are included by reference herein Limited Warranty American Medical Sales Inc warrants that a the Software Product will perform substantially in accordance with the accompanying written materials for a period of one year from the date of receipt and b any American Medical Sales Inc hardware accompanying the Software Package will be free from Form 330 4 134 Rev 07 Page 39 a Ais CateLLa pacs Affordable Upgradeable Enterprise PACS PACS 5M User Manual defects in materials and workmanship under normal use and service for a period of one year from the date of receipt or for the period of time indicated by the manufacturer of a specific piece of equipment if that period is longer than one year Any implied warranties on the Software Product or the equipment pieces are limited to these stated periods WARRANTY Except for the limited warranty specified above AMERICAN MEDICAL SALES INC AND IT
43. e it fills Waiting until the drive is full will cause back up images to migrate to other locations on your hard drive and will require billable maintenance work to recover and save to a backup drive Removing and Replacing the USB Back Up Before you remove the USB Back Up drive the CQUCLLGQ PACS 5M computer must be completely powered off After powering off the computer unplug the USB back up and replace the back up with a new one supplied or recommended by AMS DO NOT ATTEMPT TO UNPLUG OR CHANGE THE USB HARD DRIVE WHILE THE PACS 5M COMPUTER IS RUNNING THIS WILL CAUSE THE UNIT TO CEASE FUNCTIONING PROPERLY AND BILLABLE RE CONFIGURATION BY AMS WILL BE REQUIRED BEFORE REMOVING AND REPLACING THE USB HARD DRIVE CALL AMS FOR INSTRUCTION DOING THIS INCORRECTLY MAY DAMAGE THE UNIT AND CAUSE BILLABLE REPAIR WORK Once removed backup USB hard drives should be individually stored and the dates of the images stored should be written on the case for easier retrieval Protect backup USB hard drives taking care not to drop or scratch them keep them away from magnetic fields and store them in a safe location preferable offsite Form 330 4 134 Rev 07 Page 31 Ais CateLLa DACS Affordable Upgradeable Enterprise PACS CHAPTER 13 Installing LAN WEB Licenses on Remote PC s cateLLa PACS 3M comes with three LAN software licenses which may be installed on PC s connected to your network to allow viewing of images in differ
44. ent locations within your facility Or you may upgrade your PACS 3M to allow remote viewing over the internet via a WEB license this requires the purchase of COUCLLO WebServer software To install these LAN or WEB licenses follow the instructions below PACS 5M User Manual Step1 Download Catella viewing software onto computers via the Internet 1 Goto www digitalams com support downloads You should see the screen shown in Figure 40 2 Download Cat4 Dicom Viewing Software Click on Open or Run option and allow the program to download to your computer Accept the licensing agreement and all default selections such as typical installation At the end of this process select the Finish button 3 A Catella icon Figure 41 will auto install on your desktop Double click on the icon The Serial Number Screen Figure 42 will appear DISITAL 5 rq z T m To GO 4 aiii ouman worrLow DEALERS EWS PusuicaTsons BUPRORT contact us Lig YOUR DIGITAL FUTURE STAR T 5 HERE dip Meee Ges ee a i a A Cals DG Geel Viewing Somat ToL CL Log Me in Hamachi ie KaT i Radmin 22 EC Oui Radmin 2 0 Viewer CL Cul Radina Oo Sarva CA CD Figure 40 Download Screen Figure 41 Catella Icon Step 2 Call AMS for your serial number Our number is 310 219 3200 Select option 5 and then option 1 or extension 337 bd Write down the number given to you by the AMS service te
45. er numbers Export This Image This allows the image to be saved as a jpg file on your hard drive under the name you give it You can then import the image in other programs such as teaching files As a default the image will be named and saved in a Key Images folder This key also appears in the Annotations submenu Advanced Window Level Options Advanced WINDOW LEVEL features may be selected from the Use File Values Advanced WINDOW LEVEL Option Box Soft Tissue Lung Liver Manual Control using Slider Bars Use the trackball Bone cursor to move the slider bars up or down to increase or decrease the respective values The numerical interpretation is displayed at the center bottom of the window Figure 7 Advanced WINDOW LEVEL Box Select Preference Value CacCcLLa PACS 5M allows each doctor to set preset values for each imaging modality CR CT MR NM AS RF US DX MG or XA COUCLLG PACS 5M comes with a number of Form 330 4 134 Rev 07 Page 8 PACS 5M User Manual Ais cateLLa DACS Affordable Upgradeable Enterprise PACS factory preset default values for CT and MR These will need to be tested and may need to be modified after installation See Chapter 9 on how to set these values If presets have been entered for this imaging modality they will appear in the preference table To change images to a set of specific preset values go to the preference table and click on the desired description If the
46. eries does not have the number or type of slices necessary to allow for reconstruction a minimum of four parallel slices is required the MPR button will be grayed out In some instances the original images allow for reconstruction but with less than optimal MPR views In these cases cateLlLa PACS 5M displays a warning but still allows for MPR Figure 23 MPR screen presentation The quality of reconstructed images depends on a number of factors many of which are beyond the control of the MPR function It is therefore important that neither treatment nor diagnostic decisions should be based solely on the results of MPR analysis All notes and cautions regarding the COCCLLG PACS 5M s MPR function apply equally to information exported from this product for example a CD or printed report Users should ensure that recipients of this information are familiar with the notes and cautions supplied here Form 330 4 134 Rev 07 Page 21 a Ais CateLLa pacs Affordable Upgradeable Enterprise PACS PACS 5M User Manual CHAPTER 7 CREATING A PATIENT CD Creating a CD cateLLa PACS 5M allows you to burn copies of patient images onto a CD with or without viewing software that will allow the CD to self play when inserted into most Windows based PC s The COCCLLA robotic CD Burner will create the CD without manual intervention and will automatically print a CD label including information about your instit
47. eserve the images and to provide them to the Workstation upon request cateLLa Image Gateway A Receive Images Upon receipt the COUCLLO Image Gateway sends a message to the originating modality that the image was properly received The COUCLLO Image Gateway puts its highest priority on receiving and acknowledging images Other tasks are relegated to lower priorities This spares the operators at the modality from constantly having to resend images that were not properly received A file on the COUCLLQ Image Gateway C Program Files AMS Archive Backup Backup in1 contains the IP address of the modality that has authority to send images to the COCCLLO Image Gateway This file is not user modifiable but may be examined to see the image inflow B Distribute Images Images will be automatically routed to destinations Workstation Archive according to routing rules These rules are set up during or prior to installation but may be changed The Destination Control screen in the Gateway program displays the approved destinations e g Viewstation Archive Removable Media AMS Offsite Back up You may elect to temporarily remove a destination from receiving images by clicking on the Skip box next the destination s name You may change the priority of recipient destinations by selecting the Priority button and then dragging the destinations into the desired sequence and clicking Save and Exit Catella Gateway version 4 5 37
48. ft click The line will appear along with measurement of the imaginary angle created at the point where the line intersects a horizontal line in the same color as the first line Move cursor to desired start point on the image and left click Move cursor to desired end point on the image and left click again This will set the line and display the mid point of the line 4 Click on the desired end point of the second line The angle measurement will freeze LINE 1 From the Annotation Menu click on LINE 2 Move cursor to desired start point on the image and left click 3 Move cursor to desired end point on the image and left click again This will set the line MID LINE 1 From the Annotation Menu click on MID LINE 2 3 Other Annotation Functions Show Annotations To clear measurements and annotations from the screen without deleting them deselect Show Annotations If you check the Show Annotations box again the measurements and annotations will reappear Edit Selected To edit or delete a text annotation press the Edit Selected button and then make a box around it using a left click and drag Then you may edit or delete the text Delete One To delete a non text annotation simply select Edit Selected click on the annotation or make a box around it using a left click and drag and press the DELETE ONE button Delete All To delete all annotations on an image select DELETE ALL A warning box will appear asking you to
49. he Archive select Edit Images The following screen will appear Type the patient ID in the upper left hand box The patient s image files will display in the large box on the left Figure 39 Edit Image Screen From the large box click on the next to the series that has the images to be changed or deleted Highlight the image to be changed or deleted or highlight first image and click Skip This Image until you have highlighted the image you want to change A thumbnail of each image will display to assist you in finding the desired image Click on Field to Change Patient name or Patient ID as appropriate Then enter the new name or ID information in the boxes under the red warning box To make the changes press the Change This One Image or Change Remaining Images button You may also delete all images under a specific ID by using the Delete buttons IMPORTANT NOTE The functions discussed here should only be used by a trained system administrator SIGNIFICANT LOSS OF DATA CAN OCCUR IF THESE FUNCTIONS ARE USED INCORRECTLY To close this screen press the Exit button CONTACT YOUR SYSTEM ADMINISTRATOR TRAINED DEALER OR AMS BEFORE USING THESE FUNCTIONS E Other Administrative Tasks On occasion one or more of the DICOM engines may become stuck and have to be reset The Reset DICOM 1 button is used for this purpose ONLY AMS OR YOUR SYSTEM ADMINISTRATOR SHOULD DO THIS
50. is product Figures used in this manual are representative only and may vary from what appears on the screen Attempts have been made to include all user functions but there may be variations with your installed version See your system administrator for updates Although COUCLLO products where applicable adhere to the DICOM 3 0 standard and are designed to be compatible with a wide range of other devices that also adhere to this standard device specific variations may occasionally occur which require intervention or adjustment Should incompatibility appear to an issue please contact your system s administrator so that they can contact the responsible vendors to discuss the related issues ce Power outages power surges storms temperature and humidity may affect computer equipment network equipment and communication devices and networks to which software is associated It is the responsibility of the user to protect the equipment and provide the environment to handle these possible issues If you are a third party installer not the end user you are required by the United States of America Food and Drug Administration FDA to maintain records relating to the installation and testing of this equipment These records must be maintained by you for FDA review It is recommended that these records be kept for the life of the product plus ten 10 years If the installer is unable to maintain these records at its place of business the records shou
51. it it into the completed disc stack e If you have forgotten to load CD s into the stack in the robotic unit an error message will appear Reload the media stack and Click OK The CD will now burn properly andl You can continue to use the workstation while a CD is burning Simply minimize the progress box on the screen or move it out of the way by right clicking on the bar at the top of the box and dragging the box to another location ad To burn a second CD with the same images click on the image to restore the Print Image button on the Menu Then you can begin the CD burning process again Patient CD s should be put into labeled jackets or boxes Writing on the CD itself may degrade the quality of the images over time although this may not be a primary concern since the images can always be re copied from the archive Form 330 4 134 Rev 07 Page 22 Ais CateLLa DACS Affordable Upgradeable Enterprise PACS PACS 5M User Manual CHAPTER 8 DICOM IMPORTER cateLLa DICOM Importer allows you to quickly and easily add DICOM image files to a patient s record in the CateLLa Archive Although most commonly used to import images from CD s and USB drives the software also allows for the selection of DICOM files accessible on your computer network These could include images originally on DVD s or diskettes or elsewhere on your network or even on another institution s network provided you have access to that network
52. l Ole lers PACS 5M User Manual Affordable Upgradeable Enterprise PACS CHAPTER 17 IMPORTANT NOTES CateLLa PACS 5M display pre recorded and previously stored digitized diagnostic images patient information and associated data using computer systems supplied with the workstation and databases available from the user s facility The intended purpose of this device is to allow health care professionals to view the electronically available images and other patient information for review evaluation and possible treatment planning The CQUCLLG PACS 5M Version 4 0 is a medical image and information management system that allows easy viewing selection processing and media interchange of multi modality medical images from a variety of diagnostic imaging systems The CQUCLLG PACS 5M interfaces to various storage and printing devices using DICOM or similar interface standards The COUCLLG PACS S5M displays stores and prints to CD s images received over the internet or on CD s or from medical modalities which may include any of the following inter alia CT MR NM AS RF US DX MG or XA or digitizers The COUCLLO PACS 5M Version 4 0 can perform other user defined post processing functions such as multi planar reformatting of images The COQUCLLO PACS 5M can display processed data from certain FDA cleared third party image processing systems that create DICOM output such as 3 D rendering and orthopedic templating if these optio
53. lay orientation markers Form 330 4 134 Rev 07 Page 24 a N CateLLa PACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS Measurement Units Choose to use centimeters or millimeters as the measurement unit for Annotations Window Level Preferences CatcLLa PACS 5M allows you to establish preset window and level preferences for each of ten modalities In addition you can give each preference a unique description These will appear when the Window Level Tool Window is used Modality Abbreviation Full Name i i AS Angioscopy lt CR Computed Radiography Modality Bellinga for Conpubed Radiography CT Computed Tomography CRF DX a MR Magnetic Resonance a la e mi mm cio NM Nuclear Medicine SMO FR ergy RF Radio Fluoroscopy di a US Ultrasound ee at XA X Ray Angiography MG Mammography DX Digital Radiography OK Log Ou Figure 28 Window Level Preferences To enter preferences first select the modality then enter the name window value and level value for each preference These are user specific preferences and not applicable across the institution DICOM Transfer This tab is used to select the DICOM Tools Window Level Preferences header information that will appear on the monitor C e There are eleven elements to select from In ii addition this tab can be used to reset the DICOM Piom F
54. ld be forwarded to American Medical Sales Inc at the following address current as of 2005 confirm address before mailing American Medical Sales Inc Installation Records 13105 S Crenshaw Blvd Hawthorne CA 90250 5517 United States of America Our authorized representative is CEpartner4U Esdoornlaan 13 3951DB Maarn The Netherlands Tel 31 0 6 516 536 26 Form 330 4 134 Rev 07 Page 38 A S etejaa enol Ole ler PACS 5M User Manual Affordable Upgradeable Enterprise PACS CHAPTER 18 LICENSE AGREEMENTS The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties The Software Product is licensed not sold The basic license grants you a non exclusive non transferable and personal license to use one copy of the Software Product on one computer If the computer is connected to a network this license does not allow you to use the Software Product on other computers on the network unless otherwise specified in your sales agreement Multiple Users The Software Product may be installed and used within a multi user or networked environment on up to the number of computers and stations specified in your sales agreement If so it may be accessed at any such computer s and station s only by authorized users and only up to the number of users specified in such sales agreement You may not reverse engineer decompile or disassemble the
55. nal modules are purchased With proper links the CQUCLLGQ PACS 5M can also access RIS and HIS systems and can be used to review patient information The cartela PACS 5M Version 4 0 is not intended for use for primary diagnostic interpretation of mammographic images Effective use of the COCCLLO PACS 5M requires adherence to modality imaging protocol requirements and the imaging manufacturers instructions regarding maintenance and calibration of the modality imager Patients must be instructed to avoid movement during their imaging exams to minimize misregistration of images Achieving satisfactory registration will contribute to optimizing the performance of the COUCLLO PACS 5M CaCCLLG PACS 5M s measurement accuracy is limited to modality imaging system accuracy and site specific imaging techniques All digital images and associated data displayed by this device are presented for the interpretation of the health care professional as is any image or patient information All medical professionals and personnel using COLELLO PACS 5M must be trained in the use of the device by American Medical Sales or by an authorized CAUCLLO PACS 5M dealer These devices can be a software and hardware component in a complex and layered computer hardware and software system which provides storage display and network communications for medical practitioners at various levels of decision making This manual is not intended to be a definitive explanation of th
56. nd annotate images in a study so that this information can be transferred to the referring physician Select ANNOTATE from the Activity Menu A special Annotation submenu will appear below the Activity Menu You cannot Annotate an image that has been rotated or flipped until it is back in its original position You may annotate an image with an ARROW a CIRCLE or with TEXT overlay The process is similar to that used in any common drawing program Select the mode you wish to enter by pressing one of the three Annotation buttons Move the cursor to the area of the image you wish to highlight 1055x1282 Actual siz Ld o Delete Delete Export This Image Figure 8 Annotation submenu When using the ARROW press the left mouse button where you wish to place the arrow s point and while holding the button down move the mouse to make the rest of the arrow Release the mouse button where you wish to place the end of the arrow When using the CIRCLE press the left mouse button and while holding the button down move the mouse in a circular motion towards the area of interest Release the mouse button when the circle has enlarged to cover the area of interest When using the TEXT press the left mouse button at the location you wish to begin the text comment to draw a text box Begin to type and press the lt Enter gt key if you wish to start a new line To delete any typing select it and press the delete key Fo
57. ned to the workstation You can select from three compression levels at which your images will be returned Lossless Lossy Highest Quality and Lossy Fastest Since CQAUCLLO PACS 5M is operating within a network it is strongly recommended that only Lossless compression be used for image retrieval Lossy compression will not result in appreciably faster retrieval times within a facility and image quality may be compromised OK On the CAUCLLA PACS 5M there are two ways to move to a new patient s images One way is to indicate that the patient has been diagnosed using the OK function This will move the patient s image files from the Pending to the Completed portion of the Worklist Completed or diagnosed cases are then aged off of the Workstation according to time parameters set by your system administrator Using the OK function is the proper way to indicate a case has been diagnosed and needs no further review The second way to move to move to another patient s images on the CAUCLLG PACS 5M is to do so without diagnosing the first patient perhaps in order to consult with another professional Simply call up the Worklist and select another patient The first patient s images will then remain on the Pending portion of the Worklist aad Helpful hint Always use OK when no further reading is required This eliminates the costly inefficiency of double reading It also keeps the size of the active Worklist
58. other session Form 330 4 134 Rev 07 Page 19 si PACS 5M User Manual Als CateLLa PACS Affordable Upgradeable Enterprise PACS CHAPTER 5 MULTI FRAME IMAGES Setting Display Configurations You may select how you wish to view image series mage series can be viewed in l up or Quad two over two All imaging tools function with either configuration catceLLa PACS 5M automatically adjusts the zoom factor of the images to take advantage of the monitors full viewing area Basic Image Controls Same as Others When viewing multiple image files all the same basic image controls are available These include Zoom Pan Window Level Invert Rotate Flip Image Measure and Reset In addition loop viewing and image scouts with line locators are available for MR and CT images Stack Viewing All images on CQUCCLLO PACS 5M are presented in the stack mode A series of MR images is shown below in the Quad Display mode Note that the scout image is shown in the lower right corner of each frame together with reference lines for the individual image s you are viewing In addition the current frame number and the total number of frames are displayed The following tools are available for stack viewing Zoom Enlarges the image Note that the percentage factor is listed next to the Zoom command see figure below Run Begins automatic stack viewing The length of time an image is displayed is controlled by slider bar below
59. ough the use of TCP IP addresses and ports DICOM Push There are a number of ways a workstation can receive image data under the DICOM standard In a PACS environment the most common way is for the PACS software to send images to the workstation This is called a push function COCCLLA PACS 5M is a DICOM Push compliant product Once images are pushed to the workstation they will appear on the pending portion of your worklist See Chapter 6 for more details on the worklist Query Retrieve of Historical Images CaCCLLG PACS 5M allows you to query historical images on the system s archive and retrieve them to the workstation See Chapter 4 for more details on operating COCCLLO PACS 5M s Query Retrieve feature Form 330 4 134 Rev 07 Page 4 A W caceLLa DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS DICOM Print cateLLa PACS 5M supports DICOM Print This allows users to print the patient images to a DICOM printer either film or paper This function is not part of the standard package It may be installed and configured at an extra cost See your system administrator and or CALELLA PACS 5M distributor for details Form 330 4 134 Rev 07 Page 5 EMS CateLLa DACs PACS 5M User Manual Affordable Upgradeable Enterprise PACS CHAPTER 2 STARTING THE catcLLa PACS 5M WORKSTATION Powering Up the catea PACS 5M To power up the PACS 5M turn on the components in the following order 1 turn on the roboti
60. play pre recorded and previously stored digitized images patient information an stems h the workstation and databases available from the user s facility The intended purposed of these devices is to allow health care professionals to view the electronscally available images and other patient information for review and possible treatment planning Use of these devices for evaluation and diagnosis is at the discretion of the physician Log Out Ends the reading session returns the workstation to the COUCLLO workstation login l screen but keeps the workstation ready for another ES Te user log in Figure 30 About COUCLLO Tab All digital images and associated data displayed by Catella Workstions are presented for the interpretation of the health care professional as is any image or patient information These devices will have no effect upon the original stored digital image or associated data v Form 330 4 134 Rev 07 Page 25 Ais cateLLa DACS Affordable Upgradeable Enterprise PACS PACS 5M User Manual CHAPTER 10 Image Gateway Operating Instructions In CACCLLO PACS 5M images are received from a single modality or over the internet or from a CD The CACCLLO Image Gateway program is the first recipient of the images Its function is to make a copy of the images for disaster recovery purposes as well as to route the images to the Workstation and to the CQUCLLO Archive The CQUCLLOG Archive s function is to pr
61. re are more options than can be displayed in the table a scroll bar will display By clicking Use File Values label you can instruct the system to use the DICOM file values as sent to COUCCLLA PACS 5M from the modality Contrast Equalize This adjusts the contrast of an image so that each intensity range has approximately the same number of pixels in it This algorithm may assist the health professional in visualizing subtle differences in the anatomy Activate by pressing the CONTRAST EQUALIZE button Optimize This process helps to assure that there is no pixel saturation in any area of the image The minimum value and maximum value of the window is determined and the image is displayed with the level set to the middle of this range Activate by pressing the OPTIMIZE button The image is set to these new window and or level values as soon as the option is selected and the same settings will apply to all images in the same series Reset This returns the image to the window and level settings specified in the DICOM header file Invert The Invert function reverses the black white scale for the selected image Rotate The Rotate function turns the image 90 in a clockwise direction each time the function is selected Click on ROTATE on the Activity Menu Flip Image The Flip Image function flips the image 180 on the vertical axis Click on FLIP IMAGE on the Activity Menu Annotate Occasionally the radiologist will wish to highlight a
62. rklist after a given period of time See your system administrator for details Second cases can be deleted manually Manual deletion should not normally need to be done To manually delete a case click on the DELETE MODE button Note that the button will now say SELECT MODE Clicking on the SELECT MODE button will return the Worklist to the select mode Next click on the patient s name A confirmation window will appear To confirm your desire to delete this case click on DELETE To stop the deletion click on CANCEL Deleted images will remain on the Archive so they can be quickly retrieved in case of erroneous deletion Query Retrieve cateLLa PACS 5M will query its Archive and retrieve images for patients selected at the workstation e Important definitions Query is the act of searching a database in this case the COQUCLLOQ PACS 5M Archive to see which images are available from that source Retrieve is the act of pulling the selected images to the COCCLLA PACS 5M workstation If you have configured the Prefetch option images will be automatically sent to your workstation based on the user s protocols If your system is not pre loading the historical images you need speak to your system administrator COUCLLO PACS 5M will allow you to open another case for review while the selected images are being received You can view the retrieved cases later The easiest method to retrieve past patient images is to bring them all up on
63. rm 330 4 134 Rev 07 Page 9 cateLL a DACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS Measurement cateLLa PACS 5M also allows you to take and record DISTANCE and ANGLE measurements on any image Measurements in HOUNSFELD Units are also available for MR images If the DICOM file has measurement calibration information COCCLLG PACS 5M will allow you to begin measurement processing directly If you wish to activate either the angle or Hounsfeld Units function click on the appropriate option in the Annotation Menu If measurement information is not sent with the DICOM file cCateLLa PACS 5M will ask that you calibrate distance before conducting a measurement Use something of known size 1 e a label An information box similar to the figure below will appear To draw a measurement calibration line select a location on the image press and hold down the left trackball button and while holding it down move the trackball in either a horizontal or vertical direction When you release the left button COCCLLO PACS 5M will indicate the line that you have just drawn and will request you supply its length Use the slide bar to adjust this as desired ARNING All measurements for this image will be based on this setting Try to keep the line either ARNING All measurements for this image will be based on this setting Try to keep the line either horizontal or vertical Horizontal and Vertical spacing assumed equal Draw
64. rolling Window Level Moving the icon up or down changes the window values of the image The image will change as you move the icon Moving the icon up increases the window number which lightens the image Moving the icon down decreases the window number which darkens the image Moving the icon to the right or left changes the level values of the image The image will change as you move the icon Moving the icon to the left decreases the level values Moving the icon to the right increases the level values Moving the icon in a diagonal direction will change both the window and level values Controlling Pan Once the image is enlarged beyond the monitor s ability to show it in its entirety you may wish to move the image to a new area of interest Moving the hand icon in the direction you wish to move the image will complete this function Wherever you touch or grab the image that point will be the central point of adjustment Note that the hand icon reduces slightly in size when you activate the pan movement Controlling Zoom Moving the zoom icon towards the top of the screen will zoom the image to a larger size Moving the icon toward the bottom of the screen will zoom the image to a smaller size Controlling Stack Holding the left button down and simultaneously moving the trackball so that the icon moves right will sequentially display images with higher numbers Moving the icon to the left will display the images in the stack with low
65. splayable columns are Patient ID Institution Name Modality Patient Name Time Referring Physician Form 330 4 134 Rev 07 Stat Marked as emerg ency Page 15 A s CateLLa Dacs PACS 5M User Manual Affordable Upgradeable Enterprise PACS nal Keep in mind that the DICOM standard does not tell how many images are in a series Therefore if a new study is being sent to the COUCLLG PACS 5M give it time to arrive If you are reading a study and receiving the warning that more images are arriving it is best to move on to another patient and allow time for your network to deliver all the images before returning to that patient e Note If your archive is nearly full the following warning message will appear on the worklist screen Disk Drive Almost Full Please Delete Some Patients If you do not know how to do this see your systems administrator The bottom section of the worklist provides other user functions These are described below To select a patient case to view use these commands Select Mode When in the Select Mode the Worklist can be used to call up patient images The title on the top of the Worklist indicates the mode Select or Delete Cancel The cancel button is used to close the worklist window Delete Mode The COUCLLG PACS 5M deletes cases from your worklist in two ways First COCCLLO PACS 5M will automatically remove all cases that have moved to the Completed Patients wo
66. t system that allows you to organize store view and recall DICOM images received on CD s or on a USB Drive It can also receive images from up to five modalities in your facility including but not limited to CT MR NM AS RF US DX MG or XA or digitizers With optional upgrades the CaccLLaQ PACS 5M can perform other user defined post processing functions such as 3 D visualization and orthopedic templating The COLELLO PACS 5M is not intended for use for primary diagnostic interpretation of mammographic images Figure 1 CaUCLLG PACS 5M cat ell a PACS S5M operates on standard Windows XP Pro operating systems The appropriate COQUCLLO PACS 5M software components are preinstalled on the system along with other necessary software The installation package includes all appropriate software documents and licensing documents for each software component DICOM Compliant COUCCLLO PACS 5M complies with the DICOM 3 0 standards DICOM stands for Digital Imaging and Communications in Medicine Contact American Medical Sales Inc for the latest version of the cateLLa DICOM Compliance Statement System Components cateLLa PACS SM provides all of the following PACS system components for the facility using a single CR or DR diagnostic imaging system e Diagnostic Workstation Displays images for interpretation on a 2MP or optional 3MP 20 4 high resolution medical grade monitor displaying in portrait mode keyboard and mouse e Image
67. the Product is not fault tolerant and should not be used in direct life support procedures or other activities requiring fail safe performance in which the failure of the Product could lead directly to death and you agree not to use or allow the use of the Product for or in connection with any such procedure or activity Reports You agree to prepare and submit to American Medical Sales Inc full and accurate reports immediately upon becoming aware of any adverse effect occurring during procedures in which results of the Product were used or during any other use of the Product Upgrades This End User License Agreement does not grant you any right to any enhancements updates or upgrades for the Product collectively Upgrades unless you make separate arrangements for such Upgrades with American Medical Sales Inc and pay any fees associated with such Upgrades Any such Upgrades for the Product that may be made available by American Medical Sales Incl shall become part of the Product and subject to this End User License Agreement Without prejudice to any other rights American Medical Sales Inc may terminate this license if you fail to comply with the terms and conditions of this agreement In such event you must destroy all copies of the Software Product and all of its component parts All title and copyrights in and to the Software Product including but not limited to any images photographs animations video audio music and text in
68. the monitor To do this follow these simple steps Step 1 Click on QUERY on the Worklist Window Step 2 The Query Window will appear See the figure below The name and ID of the current patient will appear in the Query Info Name box If you wish to query for a different patient click on the CLEAR PATIENT INFORMATION button Then fill in a new name or ID number Step 3 Click on the QUERY PATIENT LEVEL button ail The current status of your query will appear in the STATUS line on the lower right corner of the Query Window Form 330 4 134 Rev 07 Page 16 mara Ais CateLLa Dacs Affordable Upgradeable Enterprise PACS PACS 5M User Manual e Helpful hints jpm Lm 15 IIA Entering Partial Names will bring back all patients with those beginning letters For example Smi will bring back Smilie Smite Smith etc Entering Partial ID will bring back all patients with those beginning characters The less specific an inquiry the longer it will take and the more results will be displayed Step 4 Select the patient name whose images Fete Ky hangs LY ajani you wish to retrieve Click on the GET SELECTED IMAGES button This will close the QUERY Window and open the Figure 19 Query Window WORKLIST Window When the retrieve is complete the patient study appears as the last item on the WORKLIST if sorted by time images are received It can then be studied a Overview of Query Levels
69. to be read as well as those whose images have been read The figure below gives an illustration of a typical worklist CaQUCLLG PACS 5M lists patient name number of images for this case and the imaging modality If there are more cases than can be listed in the assigned space a scroll bar will appear to the right of each section Prefetch Prefetch is a request to the archive that is automatically generated when a patient is selected for viewing on the COUCLLAQ PACS 5M The request is user definable to include the number of most recent study ies to return for that patient Since the CQUCLLO PACS 5M may generate prefetch requests without knowing which doctor will read the images the choices are for all doctors using the COCCLLO PACS 5M Images generated within the last 24 hours will NOT be automatically retrieved from the archive in a prefetch They should already be on the COQUCLLOA PACS 5M that generated the prefetch request The information that controls the type of prefetch that will be conducted is located in the digams ini file To modify this please contact your system administrator Prefetch may be set as follows ALL Returns all previous images MRS Returns the most recent studies where is a single digit that indicates how many studies to return View Columns SELECT MODE ACTIVE about 2 783 chest Cancel Delete Mode Query Figure 18 Worklist Lef click to VIEW patient Image Sp
70. trol screen will normally remain blank as seen in the Figure below ro Query Admin Patient Tasks Up Query Level 4 Figure 35 Archive Control Screen First select the destination for the images Use the down arrow on the right side of the Destination window 1 under the large window in the middle of the screen to view all possible selections Your system has one default destination Ask your system operator about this You may search for patients by either their unique number or name You may type in as little as one character of the patient ID 2 or two letters of the patient s last name 3 All records matching those numbers or letters will be returned in the large window in the middle of the screen If there are more matches than can appear in the window a scroll bar will appear to the right of the window Once you have selected a patient you can query down the hierarchy of images for that patient by clicking on the Query button 4 The next level of inquiry will be listed below the word Query The hierarchy is Patient Study Series Image Select the images that you want sent and press the Get Images button 5 You can also just select a patient at the first level and get all images for that patient The selected images will be sent to the preferred destination To Figure 36 Query for patients starting with move up a level press the Up Query Level button 6 ID numbers with a leading 2
71. ution patient name and date of creation 1 Before you start make sure there are blank Writable CD s in the robotic CD burner s input stack 2 To burn a CD with a patient s images from the COELLO PACS 5M when viewing the patient select Print Image from the menu A box showing the CD Burner as the destination printer will appear You have the option of burning the CD with or without viewing software If you are sending the CD to a site that already has viewing software or that will be opening the images with a Windows viewer select CD Burner No Viewer This will enable the user s viewing software to open the JPG version of the images on the CD without interference from another viewing program If the site has a PACS with a DICOM Importing function it can import Figure 24 Select Print to Burn CD the DICOM version of the images on the CD into its PACS and use that viewing software to open the images 3 Click on Print The box will show CD Being Compiled Please Wait This will collect all of the images for the patient that are on the workstation and will deposit them in a folder on the C Drive of the PACS 5M server along with CD viewing software 4 The robotic arm of the CD burner will then pick up the CD and place it into the burner unit to begin recording When this process is complete it will print a label on the CD and the tray will open The robotic arm will lift the CD out of the burner tray and depos
72. y can be sorted by ID or Name Highlight the files to be removed and then press the Remove Selected Files button When finished press EXIT r IMPORTANT NOTE THIS FUNCTION SHOULD ONLY BE USED BY A TRAINED SYSTEM ADMINISTRATOR OR BY AMS SIGNIFICANT LOSS OF DATA CAN OCCUR IF THIS FUNCTION IS USED INCORRECTLY Form 330 4 134 Rev 07 Page 27 Al s CateLLa PACS PACS 5M User Manual Affordable Upgradeable Enterprise PACS E CHAPTER 11 Archive Operating Instructions A Hard Drive Archive Images sent to the COCCLLA Archive are to be stored unchanged for many years Periodically it is a good idea to check the health of the hard drive in the system This can be done with the Windows Disk Manager The background of the archive screen will change depending on the amount of remaining available storage This is definable by site Typically this is how it is set at the factory Color of Background Remaining Available Storage Green More than 20 GB Available Yellow Less than 20 GB but more than 2 GB Red Less than 2 GB These are the standard settings but levels can be adjusted for individual site requirements When the background changes to yellow you should consider your need to expand the storage capacity of the system Contact your system administrator immediately B Image Push It is possible to select images to push to a given workstation or other destination from the CQUCLLO Archive The Archive program s con
73. y press the READ NOTES button on the main menu Image Notes Saved Notes Mew Moies vense Eis Figure 12 Image Notes Dialog Box Specialty Tools cateLLa PACS 5M also features tools specifically for the use of Chiropractors These tools allow measurement and annotations for COBB ANGLES HORIZONTAL ANGLES LINE and MID LINE Type of Measurement Method COBB 1 From the Annotation Menu click on COBB ANGLE ANGLE 2 Move cursor to desired start point on the image and left click Do not drag the cursor The words Left click for end of 1 line will appear 3 Move the cursor to the desired end point of the first line and left click A line will appear along with the words draw 2 line 4 Move cursor to the desired start point of the second line and left click The line will appear along with the measurement of the angle created at the point where the two lines intersect whether that point is on or off the screen in the same color as the first line 5 Click on the desired end point of the second line The angle measurement will freeze Form 330 4 134 Rev 07 Page 11 7N CateLLa Pacs Affordable Upgradeable Enterprise PACS PACS 5M User Manual HORIZONTAL 1 From the Annotation Menu click on HORIZONTAL ANGLE ANGLE 2 Move cursor to desired start point on the image and left click Do not drag the cursor The words Left click line will appear 3 Move cursor to the desired end point of the line and le