1. gt The tubular drive makes a clicking sound to confirm gt The new master transmitter is now programmed and the old master transmitter overwritten Switch the radio switch to the inside position If the radio switch is already in this posi tion switch it to the outside and back to the inside position gt The tubular drive is ready to programme for 3 minutes Now press the programming button of the new master transmitter for 10 seconds gt The tubular drive makes a clicking sound to confirm gt The new master transmitter is now programmed and the old master transmitter overwritten Upper anti freeze mechanism The upper anti freeze mechanism helps to prevent the roller shutter from freezing in the upper limit position as the roller shutter stops just before the upper stop The distance from the upper stop is automatically cyclically checked and if necessary correc ted The upper anti freeze mechanism is deactivated on delivery Both limit positions must be set before the anti freeze mechanism can be activated The anti freeze mechanism only works if a permanent stop is set at the upper limit position of the roller shutter The anti freeze mechanism is not visible until the shading solution has reached the upper stop from the lower limit position 3 times in succession Activating Deactivating upper anti freeze mechanism Aa Open the shading solution to the upper limit position P
2. sound to confirm Then close to the permanent lower stop gt The tubular drive switches off automatically gt The limit positions are now set Changing the set limit positions Once set the limit positions can only be changed with the master transmitter 1 Shortening the range of travel the desired limit position is located inside the current range of travel Open close to the desired new limit position Press the programming button and within 3 seconds also press the DOWN button for the lower limit position or the UP button for the upper limit position and hold the two buttons down gt The tubular drive makes a click sound to confirm gt The new limit position is now saved 15 2 Extending the range of travel the desired limit position is located outside the current range of travel Attention When both or individual limit positions are deleted all the other set functions intermediate position intermediate position Il upper anti freeze mechanism obstacle detection run times fly screen protection function are deleted as well Open close to the limit position in the direction in which you wish to extend the range of travel Press the programming button and within 3 seconds also press the STOP button and hold the two buttons down for 10 seconds gt The tubular drive makes a clicking sound to confirm gt The limit position is now deleted Open close to
3. To ensure complete closing of the roller shutter curtain at the lower limit position the curtain does not reverse once it gets to ap prox 360 from the lower limit position Moving UP e Extremely large increase in the load e g ice on the end strip To ensure that the roller shutter curtain safely enters the guide tracks obstacle detection is inactive for approx 1 5 revolutions of the barrel from the upper limit position Fly screen protection function If the fly screen protection function is activated obstacle detection is activated after a revolution of the barrel of approx 140 from the upper limit position If the roller shutter curtain meets an opened fly screen door the drive stops and returns to the upper limit position The fly screen protection function is deactivated on delivery Both limit positions must be set before the fly screen protection function can be activated 1 Obstacle detection is only active in conjunction with the drive adapter for obstacle detec tion When both or individual limit positions are deleted this set function is deleted as well Activating Deactivating the fly screen protection function Open the shading solution to the upper limit position y Press the programming button on the master transmitter for approx 3 seconds gt The tubular drive makes a click sound to confirm Then re press the programming button and also the STOP and UP buttons for ap p
4. click or click click sound 11 First operation Explanation of symbols STOP button DOWN button Programming button The tubular drive clicks once to confirm y The tubular drive clicks twice to confirm The tubular drive clicks three times to confirm 1 direction switch 2 radio switch 230V AC 50 Hz M Connecting the tubular drive Connect the tubular drive to the power supply 1 A N N N ee 2 L1 mn N 3 PE N 4 Readying the tubular drive for programming Readying the tubular drive for programming by switching on the power gt Switch on the power gt The tubular drive is ready to programme for 3 minutes If several tubular drives are to be connected in parallel you can deactivate the program A ming mode on one tubular drive by switching the radio switch to the outside position after turning the power on Readying the tubular drive for programming with the radio switch Switch the radio switch to the inside position If the radio switch is already in this posi tion switch it to the outside and back to the inside position gt The tubular drive is ready to programme for 3 minutes Programming the master transmitter Press the programming button for 3 seconds when it is ready to programme gt The tubular drive makes a clicking sound to confirm gt The programming process is now complete If a transmitter is already programmed on t
5. a different groove recess These groove recesses have different sizes and allow the drive to fit exactly For round tubes First notch the tube on the motor side so the lug of the thrust ring can also be pushed into the tube There must be no play between the lug of the thrust ring and the tube Assemble the tubular drive with the relevant thrust ring 1 and drive adapter 2 In sert the tubular drive with the pre assembled thrust ring and drive adapter into the tube to achieve a form fit Ensure that the thrust ring and drive adapter are secure in the tube Mount the assembled unit comprising barrel tubular drive and idler on the box and secure the drive according to the type of wall bracket fixing with a split or spring pin After programming the transmitter position the barrel so that the roller shutter curtain can be mounted with springs or fit the anti lifting device in accordance with the manufacturer s instructions When using springs anti lifting devices we recommend you use at least three for longer tubes use three springs anti lifting devices per meter of barrel Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges Confirming the drive The drive audibly confirms each programming and deletion action The tubular drive makes a barely perceptible movement which you hear as a
6. clearance between moving parts and adjacent objects e The drive must not be carried by the mains connecting cable e All latching connections and fastening screws on the brackets must be checked to en sure that they are secure e Ensure that nothing rubs against the tubular drive such as shading solution attach ments screws etc Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti lifting devices e g Zurfluh Feller Simu GAH Alberts and Deprat These are detected automatically If the springs or the top lath are not screwed or rivetted to the barrel a point must be set in the lower limit position For sunblinds please use only the types of tubular drive designed for this purpose This type of tubular drive is designed for use in single systems one drive per barrel The tubular drive must not be used in potentially explosive areas The connecting cable is not suitable for transporting the drive Always carry the drive by the housing tube Other applications uses and modifications are not permitted in order to protect the safety of the users and others since these ac tions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from s
7. eee ec ence eee e eee ee eee eee eee nen eae eeeeeeateaesetaetaesaeeeeateategeas 10 Assembling the drive adapter with screw CONNECTION cccccccececeeeeceeeececeeeecea eae eaeeeeeeaeeeeaeeseaeeeeseeenegeaseseaseatateneensnegnanegs 10 Securing the drive against axial GISDIACSMC Mis wince ann ae eine 10 Fixing the drive adapter to the barrel dia 35 and dia 45 00 ccc cece cee ccc ee ee ee ee ee eee e eens eee e eases eens essa eae eeseeeaeaeeaeeseaeaeaeaeegeaeas 10 Mounting he driv m iNe TIO Cans een een ee ee ee 11 Son VE ee ea Po E e 11 PIES ODER AO ea nee oriol ata iba nee 12 Programming the master transmitter cuisine 13 Checking that the running direction iS C ffettk sen a ae ee ee 13 iNteligent installation management ie cia ae En een 14 Se tting th limit POSIHONS een se arena usa area A 14 Upper stop LOMO el SIOD area res ee 14 Upper point to lower DOM ec AO da ida 14 UPPER SOTO OWEN DOI apo 15 Upper point to lower StOp cin ad Er Er oaa 18 Changing the set limit positions nennen see are e e POC rien er Tas 15 DEIEUNGAINEINNIEDOSITIONS AAA Pe e nena EEEN sue schacaatesasecse 16 INeimealate DOSS IA Ren ee 17 Programming additonal transmitter ee een a EE 18 Deleting ransmitlerS sense did ee ee aibes 18 OVINO the Master ae eer recente et eit iio 19 Upper anti freeze Mechas visa RN AA a ea 19 Activating Deactivating upper anti freeze MechlanNiSM ococcccccccccnccnnonnonnonnnnncnn eee eee esse aeeeeaeeaeeaeeeeeese nennen nn
8. not in accordance with these and our other instructions can result in serious injuries e g crushing of limbs Therefore structural modifications may only be carried out with our prior approval and strictly in accordance with our instructions particularly the information contained in these Assembly and Operating Instructions Any further processing of the products which does not comply with their intended use is not permitted The end product manufacturer and fitter have to ensure that all the relevant current statutory official and in particular EMC regu lations are adhered to during utilisation of our products especially with regard to end product manufacture installation and cus tomer advice Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury Instructions for the user General information e All work including maintenance and cleaning on electrical installations as well as other system parts must always be performed by authorised specialists in particular qualified electricians e Children from the age of 8 years and persons with reduced physical sensory or mental capabilities or lack of experience and or knowledge may use these devices provided they are supervised or have been instructed in the safe use of the device and have understood the hazards involved Children must not play with the device e Systems have to be checked re
9. the desired new limit position Press the programming button and within 3 seconds also press the DOWN button for the lower limit position or the UP button for the upper limit position and hold the two buttons down gt The tubular drive makes a click sound to confirm gt The new limit position is now saved Deleting the limit positions Attention When both or individual limit positions are deleted all the other set functions intermediate position intermediate position Il upper anti freeze mechanism obstacle detection run times fly screen protection function are deleted as well O Once set the limit positions can only be deleted with the master transmitter Deleted limit A positions are displayed on the limit position status indicator Deleting individual limit positions Open close to the limit position to be deleted Press the programming button and within 3 seconds also press the STOP button and hold the two buttons down for 10 seconds gt The tubular drive makes a clicking sound to confirm gt The limit position is now deleted Deleting both limit positions Open close the shading solution to a point between the limit positions Press the programming button and within 3 seconds also press the STOP button and hold the two buttons down for 10 seconds gt The tubular drive makes a clicking sound to confirm gt The limit positions are now delete
10. to confirm Re press the programming button on the master transmitter for 3 seconds gt The tubular drive makes a click sound to confirm Re press the programming button on the master transmitter for 10 seconds gt The tubular drive makes a clicking sound to confirm gt All transmitters except the master transmitter are now deleted from the re ceiver Overwriting the master There are two ways to overwrite the master e Readying the tubular drive for programming by switching on the power e Readying the tubular drive for programming with the radio switch Readying the tubular drive for programming by switching on the power To ensure that the new master transmitter is programmed in the desired tubular drive only A all other tubular drives which are connected to the same power supply must be deactivated from the programming mode To do so after switching back on the power execute a drive or stop command using the transmitter for the given tubular drives or switch the radio switch from inside to outside If the radio switch is already in this position switch it to the inside and back to the outside position 230V AC 50 Hz N m 8 1 mn Q A es 3 PE NX 4 Now press the programming button of the new master transmitter for 10 seconds M Switch off the tubular drive power for 5 seconds then switch it back on gt The tubular drive is ready to programme for 3 minutes
11. 8 engages You will hear a click Check that the safety catch is securely in position by pulling on the drive adapter 1 Put the drive adapter 1 onto the drive shaft of the tubular drive For the assembly use an M6 x 12 screw 3 with appropriate washer 2 and suitable screw retainer Threaded hole 4 Securing the drive against axial displacement In order to secure the drive against axial displacement we recommend screwing the drive adapter to the tube Attention When drilling into the barrel never drill near the tubular drive Fixing the drive adapter to the barrel dia 35 and dia 45 Size of drive Diameter of barrel Torque Fastening screws mm mm max Nm for drive adapter 4 pc dia 35 40 mm plastic drive adapter Self tapping screw dia 4 8x 9 5 mm dia 45 50 70 mm plastic drive adapter Self tapping screw dia 4 8 x 9 5 mm dia 45 50 85 mm plastic drive adapter Self tapping screw for obstacle detection dia 4 8 x 9 5 mm dia 45 50 85 mm diecast drive adapter Self tapping screw dia 4 8 x 9 5 mm We also recommend screwing the idler to the barrel Attention Do not hammer the tubular drive into the tube or drop it into the barrel The curtain can only be secured using springs or anti lifting devices Mounting the drive in the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into
12. M by measuring the drive head and wall bracket The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al lowed for the mounted system Attention When using anti lifting devices closed brackets must be fitted The tubular drive presses the closed curtain down to make it difficult for people to reach under it or raise it Only use curtains made of sufficiently strong material such as aluminium steel or wood To prevent damage to the curtain it must run in guide tracks from top to bottom Undoing the mounting pin When pushed in the mounting pin 2 locks automatically To undo the mounting pin 2 push the tab washer 1 upwards and pull out the mounting pin 2 Drive adapter for obstacle detection If you wish to use the obstacle detection function you must use the drive adapter for obstacle detection 9 Assembling the drive adapter with drive adapter safety catch Put the drive adapter 1 onto the drive shaft of the tubular drive You can see which way to insert the safety catch 2 from its shape When inserting the drive adapter safety catch 2 into the hole 4 make sure that the locking lug
13. Obstacle detection even when using anti lifting devices axle shaft devices e Secure anti lifting device e Slight pressure applied to the roller shutter curtain makes it difficult to raise or reach under it e Suitable for rigid aluminium steel and wooden profiles e The final positions do not have to be reset Changes in the shading solution are accommodated automatically when using stop systems e Torque control in the up direction prevents damage to the roller shutter in the event of a frozen or blocked shutter e Anti freeze mechanism in the upper limit position can be enabled e Considerably lower stop load and thus considerably lower shading solution load e Smooth operation of the system and the drive increases the service life e For plug in connecting cable e Fly screen protection function Please observe these Assembly and Operating Instructions when installing and setting the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 24th calendar week in 2012 EC ECOS Explanation of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury NO ATTENTION ATTENTION indicates measures that must be taken to avoid damage to property Denotes user tips and other useful information 3 Structural modifications and incorrect installation which are
14. P5 R40 Model COT en Assembly and Operating Instructions Roller shutter drive with integrated radio receiver Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert StraBe 2 4 set anna BECKER www becker antriebe com Table of contents o earn ete PA Tee ccna e oO TT O o ee 3 AAE I A EE VOEE P o O EA 4 Se NAS HUCHON era E E T 4 IISTELICHOLIS TON ING USGI APA ee ee e Pl E O OOO E E 4 instructions Tor installation and COMMISSIONING nn sn a a nee nenne 4 Mende de Senet ee eee ee een ee ee ante eset nt eee TEN ee eee eee eee ee ee eee eee 6 Assembling and disassembling the plug in connecting CAble oocococcononcononcnnononccncnnononcncononcononcnnonnnnrnnnnrnnrnnnrnnnrenanrnenennnns 6 Assembling the plug in connecting cable x scar seien ernennen 6 Disassembling the plug in connecting cable for tubular drives dia 35 ooococcccoconcocononcononconanocnnnonnnnnnnononcnnonanconancrnananannnnans T Disassembling the plug in connecting cable for tubular drives dia 45 and dia 58 zus2usssssnenennnnennnnnnnnnnnnnnn nenn nenn nennen 8 MIST PPP a era eE y e O II EEEE R 9 A AAPP E nO OU e o st 9 Undoing the MOUNTING DIN unan en ee oi iii idad oie 9 Drive adapter tor obstacle Deren ee en De er 9 Assembling the drive adapter with drive adapter safety Catch ccccccceec
15. We hereby declare that the following product series Product designation Tubular motor with integrated radio receiver Type designation P5 16 P3 30 P5 30 P5 20 P9 16 P13 9 P4 16 R8 17 R12 17 R18 11 R20 17 R30 11 R30 17 R35 11 R40 17 R50 11 L44 14 L50 11 L50 17 L60 11 L60 17 L70 17 L80 11 L80 17 L120 11 Version C R S F P E O A0 Z9 From serial number from 134700001 complies with the applicable regulations of the following Directives Machinery Directive 2006 42 EC R amp TTE Directive 1999 5 EC Furthermore the safety objectives of the Low Voltage Directive 2006 95 EC as per Appendix No 1 5 1 of Directive 2006 42 EC have been met Applied harmonised standards EN 60335 1 2012 EN 60335 2 97 2010 EN 61000 6 3 2007 ETSI EN 301489 3 2002 EN 14202 2004 Authorised party for the compilation of the technical documentation Becker Antriebe GmbH Friedrich Ebert Str 2 4 35764 Sinn Germany This declaration of conformity was issued y 7 Sinn 18 11 2013 A Yow Place Date D Fuchs Management This declaration certifies compliance with the Directives cited but does not represent any assurance of characteristics The safety warnings in the supplied product documentation must be observed Ss BECKER gt 2 2010300 4150g 28 07 2015 Se BECKER
16. d Intermediate positions Il The intermediate positions Il are freely selectable positions for the shading solution between the two limit positions Each travel button can be assigned one intermediate posi tion Both limit positions must be set before the intermediate position is set Setting the desired intermediate position Open close the shading solution to the desired intermediate position Press the STOP button and within 3 seconds also press the desired travel button and hold the two buttons down gt The tubular drive makes a click sound to confirm gt The intermediate position is now saved Setting the desired intermediate position Press the travel button for the desired intermediate position twice within one second 2X A 2X V gt The shading solution runs to the intermediate position assigned to the travel but ton Deleting the desired intermediate position Open close the shading solution to the desired intermediate position 2xA 2xV Press the STOP button and within 3 seconds also press the travel button assigned to the intermediate position and hold the two buttons down 4 M V YY gt The tubular drive makes a clicking sound to confirm gt The intermediate position is now deleted Programming additional transmitters O In addition to the master transmitter up to 15 further transmitters can be programmed in the tubular drive Press the programmin
17. g button of the master transmitter for 3 seconds gt The tubular drive makes a click sound to confirm Now press the programming button of a new transmitter which has not yet been pro grammed in the tubular drive for 3 seconds Doing so activates the programming mode of the tubular drive for a new transmitter for 3 minutes gt The tubular drive makes a click sound to confirm Now re press the programming button of the new transmitter you wish to programme for 3 seconds gt The tubular drive makes a clicking sound to confirm gt The new transmitter is now programmed in Deleting transmitters Deleting individual transmitters O The programmed master transmitter cannot be deleted It can only be overwritten see Programming the master transmitter gt 13 Press the programming button on the master transmitter for 3 seconds gt The tubular drive makes a click sound to confirm Now press the programming button of the transmitter to be deleted for 3 seconds gt The tubular drive makes a click sound to confirm Then re press the programming button of the transmitter to be deleted for 10 seconds gt The tubular drive makes a clicking sound to confirm gt The transmitter is now deleted from the tubular drive Press the programming button on the master transmitter for 3 seconds gt The tubular drive makes a click sound
18. gularly by authorised specialists for wear and damage e Always put damaged systems out of operation immediately until they are repaired by an authorised specialist e Do not operate equipment if people or objects are within the danger zone e Observe the danger zone of the equipment during operation e Stop and disconnect the equipment from the mains power supply when maintenance and cleaning is being performed either on the system itself or in the immediate vicinity of it e Ensure that there is adequate clearance at least 40 cm between moving parts and adjacent objects Caution Safety instructions for avoiding serious injuries e Crushing or shearing points must be avoided or protected Instructions for installation and commissioning General information e Observe the safety instructions in EN 60335 2 97 Please note that this list of safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question e All applicable standards and regulations for electrical installa
19. he receiver press the programming button for 10 seconds Checking that the running direction is correct There are 2 ways to change the direction of rotation e Changing direction of rotation via the direction switch e Changing direction of rotation via the master transmitter Changing direction of rotation via the direction switch Press the UP or DOWN button gt The shading solution runs in the desired direction gt The running direction is OK If the shading solution runs in the wrong direction the running direction must be switched Proceed as follows Switch the direction switch 1 to the opposite position gt The running direction will now have changed gt Check the running direction again Changing direction of rotation via the master transmitter It is only possible to change the direction of rotation if no limit position has been set Press the UP or DOWN button gt The shading solution runs in the desired direction gt The running direction is OK If the shading solution runs in the wrong direction the running direction must be switched Proceed as follows Press the programming button and within the next 3 seconds also press both the UP and DOWN buttons Hold down the buttons for 3 seconds YIY gt The tubular drive clicks 3 times to confirm Check the running direction again Intelligent installation management Limit position status indicator A brief stopping and restarting indicate
20. he tubular drive has turned off automatically in the desired position three times Upper stop to lower stop Open to the permanent upper stop gt The tubular drive switches off automatically Then close to the permanent lower stop gt The tubular drive switches off automatically gt The limit positions are now set Upper point to lower point There is no shading solution length adjustment with this limit position setting A Open to the desired upper limit position Press the programming button and within 3 seconds also press the UP button and hold the two buttons down gt The tubular drive makes a click sound to confirm Press the programming button and within 3 seconds also press the DOWN button and hold the two buttons down gt The tubular drive makes a click sound to confirm gt The limit positions are now set Upper stop to lower point Open to the permanent upper stop gt The tubular drive switches off automatically Yoo Then close to the desired lower limit position Press the programming button and within 3 seconds also press the DOWN button and hold the two buttons down gt The tubular drive makes a click sound to confirm gt The limit positions are now set Press the programming button and within 3 seconds also press the UP button and hold the two buttons down gt The tubular drive makes a click
21. le may be used both indoors and outdoors To connect the drive to the driven part solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used The components must be installed in accordance with the manufacturer s instructions If the drive is used for shading solutions in a specially marked area e g escape routes hazard zones safety areas compliance with all applicable regulations and standards must be ensured Caution Safety instructions for avoiding serious injuries e When electrical or electronic equipment and units are operated certain components e g the power supply unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings e Be careful when touching the tubular drive as it heats up during operation for technolo gical reasons e Before installation shut down all lines and control devices that are not essential for op eration e Crushing or shearing points must be avoided or protected e When installing the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided EN 60335 e If the drive mains connecting cable is damaged it must be replaced with the same type of mains connecting cable which is available from the drive manufacturer Attention Safety instructions for avoiding property damage e Ensure that there is adequate
22. nnnnnnnnnnnnen nennen nenn 20 OS TACO CS OU Ocarina catia re O II rede nie 20 PLY SCI GCN protection TUNCHOI rauen teen a a ne ra en ee re rare ee ae area 20 Prooramming the rUn TIMOS Sneak aan nn ne dee reis A 21 SISTING the HOM DES ern ee ee ida do it 21 pc nn on Po o A 21 ITEC AIG AM EP E E EEE E E RI e UI ee 21 Tecnica danar A E A E o o E E o e OU Oo 22 espe cio AAA A O A rn 22 Waa A e Eo PO O e E A IA 23 Sample WII Alt todavia aia 24 Declaration OF CONTO TY sic rre ad cipstencencscagytiaauinsecenlvewiadiaWenutwusiasendaattaid aids E ENEE Ena aE EEES 25 These tubular drives are high quality products with the following features e Optimised for roller shutter operation e Individual group and central radio control e No need to run wires to a switch or relay control device e Any combination of drive and transmitter possible e Simple to set the limit positions with the transmitter e Installation without stops possible from upper point to lower point e Two freely selectable intermediate positions can be set e Flexible radio grouping can be altered at any time with no need to install uninstall e Integrated memo function facilitates easy programming of one or two switching times on daily repeat e Automatic detection of the lower limit position when using springs in conjunction with the drive adapter for obstacle detec tion e Automatic detection of limit positions thanks to intelligent electronic system with stop systems e
23. osal for this product in your country The packaging material must be disposed of properly Maintenance These drives are maintenance free 62 BECKER 2 Technical data dia 35 Model P5 CO1 P9 CO1 Type P5 16C PROF P9 16C PROF Rated torque Nm Output speed rpm 16 16 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Degree of protection IP 44 Frequency 868 3 MHz Emission sound pressure level dB A lt 70 Technical data dia 45 Model R8 C01 R12 C01 R20 C01 R30 C01 R40 C01 Type R8 17C R12 17C R20 17C R30 17C R40 17C PROF PROF PROF PROF PROF i Fes cureconsampton os os os oo ws Emission sound pressure level lt 70 dB A What to do if Tubular drive is not functioning Program new transmitter immediate vicinity of the tubular drive Thermal protection switch in tubular drive has tripped Wait until the thermal protection switch in the tubular drive is reactivated Shutter direction on tubular drive cannot be set Delete limit positions see Deleting the limit positions gt 16 and reset the shutter direction Incorrect shutter direction after deleting limit positions Change the shutter direction using the master transmitter or the direction switch on the tubular drive Tubular drive has detected an increase in load Briefly run the curtain in the opposite direction then continue in the desired direction Tubular drive is overloaded Use a higher torq
24. ress the programming button on the master transmitter for approx 3 seconds gt The tubular drive makes a click Sound to confirm Then re press the programming button and also the STOP and UP buttons for approx 3 seconds gt The tubular drive clicks 3 times to confirm Obstacle detection Caution Obstacle detection is only active in conjunction with the drive adapter for obstacle detec tion In addition please note that the drive must be pushed in to the shaft as far as the band of the thrust ring Use of the drive s obstacle detection system as personal protection is not permitted It has been designed exclusively to protect the roller shutters or sun protection system from be ing damaged If the drive is correctly installed it switches off when it detects obstructions or shutter faults and reverses a short way in the oppos ite direction and thus away from the obstacle If reversing is interrupted a further drive command is only possible in the direction of reversing Travel the shading solution without interruption until the tubular drive stops automatically It is now possible to travel in both directions again The following are detected Moving DOWN e A curtain jam when closing due to objects on the window sill or sticking of the lateral guide tracks If the tubular drive switches off in the area of the upper limit position it checks once more whether an obstacle is present
25. rox 3 seconds gt The tubular drive clicks 3 times to confirm Programming the run times This function is only available with MemoControl transmitters from the Becker Centronic range of control units This tubular drive can save one switching time for one UP and one DOWN cycle In the Timer slide switch position the UP and DOWN cycles are automatically repeated every 24 hours It does not matter what position the manual auto slide switch is in when programming the switching time Stored switching times are overwritten 1 To program the DOWN run time the tubular drive must be in the upper limit position and to program the UP run time it must be in the lower limit position Wait for the time you wish the automatic drive command to be executed At the desired time press and hold the relevant direction button until the tubular drive briefly stops after approx 6 seconds and then continues to the limit position 4 Release the direction button The tubular drive has saved the current time for this direction of travel Deleting the run times 6 When deleting both run times are always deleted To delete the UP and DOWN run time press the STOP button for 10 seconds The tubular drive makes a click click sound to con firm The run times are now deleted Disposal This product is made of various materials which must be disposed of properly Find out about the applicable regulations on recyc ling or disp
26. s that no limit position has been set in that direction of movement Completion of installation following automatic setting of limit positions The drive saves the limit position permanently once the upper limit position is reached 3 times in succession Installation is then complete If the limit position is set above a point this is stored permanently Setting the limit positions The limit positions can only be set with the master transmitter The shutter direction must A be correct When setting the limit positions the tubular drive runs in dead man mode with the limit position status indicator The upper limit position must always be set first When setting the upper limit position ensure that the roller shutter curtain is not pulled out of the guide tracks When first installing using springs and adjusting the limit position to lower stop the barrel in the lower limit position turns approx 1 4 of a turn further than usual In doing so the tubular drive is able to automatically detect the use of anti lifting devices or springs The tubular drive switches off automatically Attention When operating the tubular drive without the drive adapter for obstacle detection if using springs a point must be set in the lower limit position There are 4 ways to set the limit positions e Upper stop to lower stop e Upper point to lower point e Upper stop to lower point e Upper point to lower stop The limit position becomes fixed after t
27. tion Prior to disassembly the power supply to the connecting cable must be disconnected On drives with a diameter 045 or 058 insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver dia 45 and dia 58 C plug locating latch Installation Assembling the drive Attention To connect the drive to the driven part solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used Prior to mounting the fitter must ensure that the masonry and the system being motorised are sufficiently robust drive torque plus weight of the shading solution Caution Electrical connections may only be carried out by a qualified electrician Prior to assembly the power supply must be disconnected and secured Please give the enclosed connection information to the responsible electrical contractor These drives cannot be operated with conventional switching elements switches timers and the like If you want the roller shutter curtain to open to the upper stop proceed as follows The roller shutter curtain must be prevented from being drawn into the shutter box with a mechanical stop or an angled end strip With face fixed elements we recommend con cealed stops in the guide tracks Calculate the space required at the side
28. tion must be complied with e All work including maintenance and cleaning on electrical installations as well as other system parts must always be performed by authorised specialists in particular qualified electricians e Only use spare parts tools and accessory devices which have been approved by the drive manufac turer Unapproved third party products or modifications to the system and its accessories represent a risk to your safety and the safety of others This means that the use of unapproved third party products or modifications which have not been agreed with or approved by us are prohibited We do not accept li ability for damage or injury arising from such actions Position control devices within sight of the driven product but away from moving parts at a height of over 1 5m Permanently mounted control devices must be positioned where they can be seen Rated torque and duty cycle must be suitable for the requirements of the driven product Technical data rated torque and service life can be found on the type plate of the tubular drive Moving parts of drives must be installed at a height of over 2 5 m above floor level or any other surface from which access to the drive is gained To ensure safe operation of the system after commissioning the limit positions must be correctly set programmed in Drives with a HOSVV F connecting cable may only be used indoors Drives with a HOSRR F SOSRN F or OSRN F connecting cab
29. uch actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from improper usage Attention Only use anti lifting devices if the roller shutter laths are sufficiently strong The closed curtain must not project beyond the guide tracks or else there is a risk of the joint between the top two laths being subjected to excessive strain and getting damaged Assembling and disassembling the plug in connecting cable Assembling the plug in connecting cable Insert the dead connecting cable into the drive head until the locating lug clicks into place in the drive If necessary use a Suitable flathead screwdriver to assist with insertion Set the screwdriver into one of the two plug grooves provided for this purpose Check that the cable is properly engaged 1 locating lug Disassembling the plug in connecting cable for tubular drives dia 35 Caution Prior to disassembly the power supply to the connecting cable must be disconnected On drives with a diameter 35 insert a suitable flathead screwdriver between the locating lug and the snap in pin so that the snap in pin releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver A snap in pin 7 Disassembling the plug in connecting cable for tubular drives dia 45 and dia 58 Cau
30. ue tubular drive Switching times cannot be set on tubular drive Use transmitter with manual auto slide switch Tubular drive does not operate at the set switching time Switch manual auto slide switch to Tubular drive stops arbitrarily cannot be restarted in the same direction Switch the slide switch on one transmitter from Y to If the slide switch is already at switch it to Y and back to Set switching times change Frequent 230 V AC power cuts Fluctuations in the 50 Hz mains frequency Use a TimeControl transmitter and set the desired switching time there During the programming run the drive stops short of the limit For safety reasons the drive reacts sensitively to sluggishness position to be programmed during the programming run in order to prevent damage Briefly run curtain DOWN and subsequently UP until you reach the upper limit position Ventilation slots of the roller shutter do not close fully Delete the limit positions see Deleting the limit positions gt 16 and set the limit positions as per to lower point Setting the limit positions gt 14 to this end first programme the lower limit position lower point and then the upper limit position 23 Sample wiring diagram cp SOLLEN a J3ZQ BECKER ANTRIEBE GMBH BECKER Friedrich Ebert Str 2 4 Original 35764 Sinn Germany EC Declaration of Conformity Document No Month Year K004 11 13