Home
Sales Instruction Training for ClampCut
Contents
1. by handed users can use their left the other hand app 3 cm from closing the white clamp around hand for this procedure the infant s stomach the umbilical cord Page 3 of 8 Version 1 July 2011 Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk FATHER CUT Positioning ClampCut for the Making sure that the umbilical The father can cut the umbilical father cord is placed correctly see the cord by simply pushing the slider arrow above apply ClampCut by into the housing while the midwife closing the white clamp around holds ClampCut the umbilical cord 4 Sometimes the father wishes to cut the umbilical cord If this is the case simply use the correct grip on ClampCut and let the father push the slider into the housing as shown in the pictures above 5 To remove the clamp when and if this is necessary depends on the hospital s procedure use ClampOff as demonstrated below REMOVAL OF THE CLAMP USING CLAMPOFF Hold the umbilical cord with one Place ClampOff in the hole of the Cut the clamp by pressing the hand and ClampOff with the clamp handles together The clamp can other now be opened Page 4 of 8 Version 1 July 2011 Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk Incorrect grip There is one way in which ClampCut can be used incorrectly by using the correct grip incorrectly If the u
2. Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk ClampCut and ClampOff User s Manual Page 1 of 8 Version 1 July 2011 Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk Purpose The purpose of this manual is to describe how amp ClampCut and ClampOff should be used ClampCut is ja disposable device used to clamp and cut the umbilical cord of a newborn baby Later ClampOff can be used to remove the clamp again The manual has been designed for Certified Users and Trained Users and contains Price Invena s Certification Policy astep by step procedure for using ClampCut and ClampOff alist of frequently asked questions and corresponding answers Certification Policy To ensure that all users of ClampCut apply the product correctly Price Invena enforces a certification policy which is described below Certified Instructor Cl has been trained by Price Invena to sell ClampCut and to train and certify Certified Users As described in the box to the left there are 3 user levels each of which has different degrees of training The following is a list of rules regarding the use of ClampCut If you are a Certified User CU You can train other hospital staff to become Trained Certified User CU has completed the ClampCut Training can purchase and apply ClampCut and c
3. an train staff to become a Trained User Trained User TU has been trained by a CU and is allowed to apply ClampCut Page 2 of 8 If Users TU You are responsible for keeping a logbook of the TUs you have trained Logbooks are provided by your sales representative You are allowed to apply and purchase ClampCut You must have a certificate with your name date of issue issuing party and name of your hospital The certificate is personal and cannot be handed over to a third party The certificate must be renewed every 12 months ou are a Trained User TU You can apply ClampCut Version 1 July 2011 Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk How to apply ClampCut The following is a step by step procedure describing how to apply ClampCut 1 ClampCut consists of two components the white clamp and green slider amp housing 2 ClampCut can be applied using the correct grip both of which are demonstrated in the pictures below components 3 After the clamp has been applied it is possible to count the 3 veins in the umbilical cord ClampCut s CORRECT GRIP BOTH HANDS Grasp the umbilical cord using Making sure that the umbilical Cut the umbilical cord by pushing one hand and position ClampCut cord is placed correctly see the the slider into the housing Left around the umbilical cord using arrow above apply ClampCut
4. depending on the preferences of the hospital staff the clamp can stay on the umbilical cord indefinitely or be removed with ClampOff Can ClampCut be used more than once No ClampCut is a disposable product How should I apply ClampCut The white clamp must always face the infant s stomach e Can the proud father still cut the umbilical cord Yes if the obstetrician and or midwife holds the device as shown in figure the father can cut the cord by simply sliding ClampCut e What if the umbilical cord is too big ClampCut has been designed to fit all sizes and types of umbilical cords The father can cut the e How close to the infant should I apply umbilical cord by pushing the ClampCut The recommended distance from the slider while the midwife holds the housing infant s stomach is 3 5 cm What if the umbilical cord is covered with gel ClampCut should not be placed over the gel Instead place ClampCut further away from the infant s stomach e How far away from the infant can apply ClampCut Although the recommended distance is 3 5 cm it can easily be applied 5 10 cm or more from the infant s stomach e What if want to remove the clamp The clamp can easily be removed using ClampOff a specially designed clamp remover also sold by Price Invena Notice that other Clamp removers cannot be used to remove the clamp but ClampOff is capable of removing existing clamps on the ma
5. in less than 2 seconds in one easy movement Questions lf you have any questions or comments please feel free to contact Price Invena at info priceinvena dk or your local Price Invena sales representative Version 1 July 2011
6. mbilical cord is not placed between the index and middle fingers it will be pulled out of the clamp when the slider is pushed into the housing as demonstrated below f Incorrect grip on ClampCut Notice the Result of using the incorrect grip the umbilical cord is on the wrong side of the umbilical cord blocks the closure of the index finger it should have been clamp between the index and middle fingers Evacuating the placenta ClampCut can be used for evacuation of the placenta and thereby save the use of an extra pair of forceps this is shown below The umbilical cord is wound around the The slider and housing can then be Slider used to pull when the placenta is being evacuated Page 5 of 8 Version 1 July 2011 Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk Frequently Asked Questions This is a list of frequently asked questions and their corresponding answers e Can I still control the 3 vessels in the umbilical cord Yes when the clamp is applied it is easy to count the veins in the umbilical cord e Can take blood samples from the placenta Yes the placenta side of ClampCut can be opened and closed as needed Can I use ClampCut if I m lefthanded Yes ClampCut can be used with both hands remember to show that in the demonstration e When can the clamp be removed After 12 14 hours it is safe to remove the clamp but
7. ord can be compared to cutting a pressurized garden tube the blood can splash in all directions in an uncontrolled manner ClampCut prevents this from happening What if the pouch breach ClampCut will not be sterile How many times can ClampCut be used ClampCut can only be used once time ClampCut is a disposable single used product lf you have a question which is not on the list please ask your local Price Invena sales representative or send an e mail to info priceinvena dk Page 7 of 8 Version 1 July 2011 Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk ClampCut was tested at Rigshospitalet in Copenhagen Denmark and the results were published in an article in Acta Obstetricia 0 blood splashing 0 repositioning of clamp 0 alternative method necessary Page 8 of 8 Advantages using ClampCut Compared to the competing products ClampCut has many advantages among these are e When ClampCut is used correctly the risk of blood splashing is eliminated e Each device is assembled and tested 100 before it is packaged and sterilized no risk of faulty devices e Clinically proven that there is a 0 risk of blood splashing no risk of HIV and Hepatitis contamination e Disposable product guaranteed sterililty and razor sharp blade every time No re sterilizing necessary e Fast and efficient application
8. rket Checking the 3 vessels ClampOff Page 6 of 8 Version 1 July 2011 Price Invena ApS Kronprinsessegade 36 2 e DK 1306 Copenhagen K Denmark www priceinvena dk Is ClampCut packed in a sterile packaging Yes ClampCut is sterilized using ethylene oxide ETO Does ClampCut contain latex or PVC No ClampCut only consists of environmentally friendly materials such as nylon 6 6 and stainless steel When the product is destructed the material ClampCut s packaging with the will turn into water vapour yellow label indicating that it is a e How does the clamp differ from what use sterilized product now The actual clamp is virtually the same as the existi ng clamps on the market which have been on the market for more than 30 years Can I still use ClampCut during a Caesarian section Yes ClampCut is particularly advantageous during a Caesarian section because it can be applied in less than 2 seconds Can I use ClampCut when the child is born with the umbilical cord around its neck Yes as shown in the figure to the left using ClampCut is a quick way to remove the umbilical cord from the child s neck There is already a lot of blood when a child is born What difference can a little blood from the umbilical cord do The blood that is normally present during a delivery that is coming from the vagina and which flows vertically in a controlled manner Cutting the umbilical c
Download Pdf Manuals
Related Search
Related Contents
Conceptronic Serial ATA & IDE to USB & eSATA adapter Multiquip C1870300404 Portable Generator User Manual KOHLER K-R10433-CP Installation Guide USER MANUAL Wordでマスターする 使えるビジネス文書 レイアウトの極意 【サンプルPDF】 Conergy ISA configurator - Solar Volltext USER MANUAL - Monitorhalterung.de Copyright © All rights reserved.