Home
V-1 - User manual
Contents
1. Control the intensity by varying pressure of a tube to the vortex head Fig 1 1 4 4 After finishing the operation disconnect the external power supply unit from electric circuit Fig 1 V 1 plus personal vortex Page 7 5 Specifications The unit is designed for operation in cold rooms incubators and closed laboratory rooms at ambient temperature from 4 C to 40 C and maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Speed control range 750 3000 rpm max speed depends on loading Maximum continuous operation time 0 0 eee eeeeeeeeeeeeeneeeteneeeeeneeeeeneeeeeaes 8hrs MixingimoduleTOFTUD S iseanan i a i from 1 5 to 50 ml Maximumimixing VOlUMEG sisi boii ied hate E E 30 ml ORD it sce asserted iai si ii i i i ii slate i i gener a a i i SURN 4 mm DIMENSIONS Liss use i si ia a ris a a i sa si 90x150x80 mm Input current power CONSUMPTION 1 aaa 12 V 320 mA 3 8 W e External power supply unit input AC 100 240 V 50 60 Hz output DC 12 V 6 AY 1 Seer eer eee a aa aisiais a aa aaa aaa a pe errr rae 0 8 kg Accurate within 10 Biosan is committed to a continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice Page 8 6 Maintenance 6 1 If the unit reguires maintenance disconnect the unit from the electric circuit and contact Biosan o
2. WEEE 2002 96 EC 8 2012 19 EU Manufacturer SIA BIOSAN Ratsupites 7 build 2 Riga LV 1067 Latvia Applied Standards EN 61326 1 Electrical eguipment for measurement control and laboratory use EMC reguirements General reguirements EN 61010 1 Safety reguirements for electrical eguipment for measurement control and laboratory use General reguirements EN 61010 2 051 Particular reguirements for laboratory eguipment for mixing and stirring We declare that this product conforms to the requirements of the above Directive s Signature Signature Svetlana Bankovska Aleksandr Shevchik Managing director Engineer of R amp D 12 06 2013 12 06 28 Date Page 11 Biosan SIA Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 http www biosan lv Version 1 04 October 2013
3. D Medical Biological Research amp Technologies V 1 plus Personal vortex for tubes py m o aw Am yi Operating Manual Certificate for version V 1AW Contents Safety Precautions General Information Getting Started Operation Specifications Maintenance Warranty and Claims oO OOF WN Declaration of Conformity Page 2 1 Safety Precautions The following symbol means A Caution Make sure you have fully read and understood the present Manual before using the equipment Please pay special attention to sections marked by this symbol GENERAL SAFETY Use only as specified in the Operating Manual provided The unit should be saved from shocks or falling After transportation or storage keep the unit under room temperature for 2 3hrs before connecting it to the electric circuit Use only cleaning and decontamination methods recommended by the manufacturer Do not make modifications to the design of the unit ELECTRICAL SAFETY Connect only to the external power supply unit with voltage corresponding to that on the serial number label Use only the external power supply unit provided with this product Ensure that the external power supply is easily accessible during use Disconnect the unit from the electric circuit before moving Disconnect the external power supply unit from power socket to turn off the unit If liquid penetrates into the uni
4. r your local Biosan representative 6 2 All maintenance and repair operations must be performed only by gualified and specially trained personnel 6 3 Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and disinfection of the unit Page 9 7 Warranty and Claims 7 1 The Manufacturer guarantees the compliance of the unit with the requirements of Specifications provided the Customer follows the operation storage and transportation instructions 7 2 The warranted service life of the unit from the date of its delivery to the Customer is 12 months Contact your local distributor to check availability of extended warranty 7 3 If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the local distributor address Please visit www biosan lv Technical support section to obtain the claim form 7 4 The following information will be required in the event that warranty or post warranty service comes necessary Complete the table below and retain for your records Model V 1 plus Personal vortex for tubes Serial number Date of sale Page 10 8 Declaration of Conformity Declaration of Conformity Eguipment name V 1 plus Type of eguipment Personal vortex for tubes Directive EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS 2011 65 EC
5. rials carefully and retain them for future shipment or storage ofthe unit Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage 3 2 Complete set Package contents V 1 plus Personal vortex for tubes icnn 1 pce external POWER SUPPLY UNI asesina A E E 1pce 1 copy Operating Manual Certificate Lai kaka aka a aka 3 3 Set up place the unit on the working area plug the external power supply unit into the 12 V socket at the rear side of the unit Page 6 4 Operation 4 1 Connect the external power supply to electric circuit 4 2 Continuous operation mode CS 4 2 1 Turn the TS CS switch fig 1 2 into CS position 4 2 2 Set the required speed using the Speed knob fig 1 3 4 2 3 Gently holding a tube with fingers at its upper part dip the tube s lower part into the conic deepening of the vortex head Fig 2 1 4 2 4 Control the intensity of mixing by varying pressure of a tube to the vortex head 4 2 5 After finishing the operation turn the TS CS switch into TS position 4 3 Touch operation mode TS 4 3 1 Turn the TS CS switch fig 1 2 into TS position 4 3 2 Gently holding a tube with fingers at its upper part press the tube s lower part to the vortex head cavity bottom Fig 1 1 Vortex will be activated when pressing the mixing cup with a test tube 4 3 3 Set the required speed desired mixing level using the Speed knob fig 1 3 4 3 4
6. t disconnect it from the external power supply unit and have it checked by a repair and maintenance technician DURING OPERATION Use only the tubes smaller or equal to 28 5 mm in diameter Do not stop the vortex head rotation with a hand Do not operate the unit in environments with aggressive or explosive chemical mixtures Page 3 Do not operate the unit if it is faulty or has been installed incorrectly Do not start operation at maximum speed Do not use outside laboratory rooms BIOLOGICAL SAFETY Itis the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment Page 4 2 General Information V 1 plus Personal vortex for tubes is designed for mixing substances in tubes using the eccentric mechanism The vortex can be used in a variety of applications including general test tube mixing tissue samples mixing cell s suspensions vortexing chemical reagents mixing etc The vortex is equipped with 20 mm diameter single fluoroplastic mixing cup for mixing one tube ata time V 1 plus is intended for two operations continuous mixing impulse mixing activated by touching the mixing cup with a test tube V 1 plus Personal vortex for tubes operates at variable speeds from 750 to 3000 rpm providing different mixing intensity from gentle shaking to intensive vortexing Page 5 3 Getting started 3 1 Unpacking Remove packing mate
Download Pdf Manuals
Related Search
Related Contents
Manual de instrucciones South Shore Furniture 3342098 Instructions / Assembly Zenoah EB430 User's Manual 取扱説明書 short PDF file - Barringer and Associates, Inc. 取扱説明書 - M sur mesure # - Marketing Community Acer K10 User`s guide JUMP&GO - InvertersRus Copyright © All rights reserved.
Failed to retrieve file