THERAPIST MANUAL - v 19-07-2011

image

Contents

1. In case a subassembly that breaks down has already been repaired twice the manufacturer shall be obliged to replace a faulty subassembly with a new one The user shall be obliged to prepare a room and all necessary utilities needed for operation of the device so that they comply with requirements of obligatory standards and with the installation manual In case the installation and operation instructions have not been observed the manufacturer shall bear no responsibility for the safety of the user or patient during the use of the unit The warranty covers any quality or quantity faults detected immediately after the subject of this agreement has been unpacked by the immediate recipient of the package Faults that occurred within the warranty period and were not reported by the user in writing mail fax e mail shall not be covered by this warranty Costs resulting from an unfounded claim shall be borne by the user The warranty shall not cover equipment damaged as a result of fire or lightning with name plate and or serial number or factory seals removed or damaged damaged due to its use in a manner other than defined in the operation manual where repairs or modifications have been done by unauthorized personnel damaged mechanically due to improper handling damaged due to force majeure 10 11 12 13 The user shall be obliged to ensure that both the equipment and its supply systems are regularly ma
2. Never lower the bed with the front head section depressed Never lower the bed whose front section s upholstery elements are depressed CAUTION Lowering the bed to the lowest possible position while its bolster is deflected may cause a collision between the bolster and the lower frame elements this can result in blocking the height adjustment mechanism In result a permanent and irreversible damage to the structure of the table may occur Pay special attention not to lower the bed with its front section folded down The manufacturer shall not assume liability for damages resulting from improper not compliant with conditions provided in this Operation Manual use of the THERAPIST table 5 PREPARING THE UNIT FOR USE 1 Select the place for the use of the table with a minimum of 80 cm clearance on each side of the unit THERAPIST table Figure 2 Recommended positioning of the THERAPIST massage table CAUTION When positioning or repositioning the table pay special attention to ensure that there are not any objects below the lower frame of the table Always safeguard against uncontrolled access of children or animals to the table or its location CAUTION Unplug the table from the mains socket while performing maintenance servicing or similar actions under the table p 2 A230 VAC 50 Hz power supply connection must be available in the vicinity of the table CAUTION When connecting the 230 VA
3. INTRODUCTION Congratulations on a perfect choice of our massage table THERAPIST tables are stable reliable and easy to use These features result from careful design manufacturing methods applied in production and the quality assurance system Reading and following instructions provided in this manual will ensure safe and long lasting use of our tables General instructions This product must be operated by qualified and trained personnel who have read this operation manual thoroughly Using operating or servicing of the product contrary to the rules and recommendations set in this user manual is prohibited as it may lead to damage for which the manufacturer shall not be liable If the performance or parameters of the product are found to be inconsistent with what the operation manual describes you must stop using the product and inform the manufacturer or the reseller immediately Every repair of the product must be done by the manufacturer s service or service authorized by the manufacturer and registered on the repair list in the warranty card Failure to do so will result in voiding the warranty This warranty will not be fulfilled if the product is used contrary to its purpose or fails to comply with the terms set in the user manual The manufacturer shall not be liable for the consequences of improper i e against the instructions in the user manual use of the THERAPIST massage tables CAUTION This sign denotes opera
4. is permitted up to 3 layers using special stackable pallets External edges of the upholstered parts are lined with foam bubble wrap and stretch foil Protect the outer edges of Therapist tables against damage while moving or transporting them 4 SAFETY MEANS Help the patient to maintain proper position before doing treatment procedures by lowering the bed top to the lowest position Likewise lower the bed top after the treatment to help the patient to get out of the bed CAUTION The TERAPEUTA family tables may not be loaded beyond their nominal capacity The weight of the patient may not exceed 150 kg Do not sit on the movable elements of the front and middle sections right wrong Do not put load on the front and rear sections in a way shown in the illustration on the left Protect electrical systems of the actuator and the mechanical system of the table against contact with liquids e g beverages water cleaning and disinfection preparations CAUTION In case of flooding the electrical system or the actuator cover with liquid of any kind immediately pull the 230VAC power supply plug off the mains socket and ask for technical inspection and electrical safety check of the table at the manufacturer s service unit or the user s maintenance department CAUTION Unplug the table from the mains socket while performing maintenance servicing or similar actions under the table CAUTION
5. of these with a dry cloth 3 Check the threaded joints periodically every six months and remove loose connections with a Phillips screwdriver hex keys no 4 5 and 6 and flat spanners 10 and 27mm Report all loose connections that cannot be removed to the manufacturer s authorized service and cease using the table until the cause of the problem is removed 7 3 Checking the gas springs Therapist tables are equipped with gas springs for easy adjustment of the front section inclination angle models S2 H2 S3 S5 S7 P3 P5 P7 and the rear section inclination angle models S3 S5 S7 P3 P5 P7 To ensure proper performance of the gas springs check the springs visually for leaks every 3 months Any perceived performance deficiency or leak must be reported to Meden Inmed technical service immediately 7 4 PERIODIC CHECK OF ELECTRICAL SAFETY The electrical safety check should be performed or ordered not less than once every 2 years and after every fault or repair of the actuator and or the power mechanism of the massage table 8 1 8 9 WARRANTY CARD The validity period of this warranty is 12 months starting from the date of purchase of the equipment as indicated in a proof of purchase A repair time exceeding 3 days regardless of the reason that caused the delay shall result in the extension of the warranty period by a time that is equivalent to the total time during which the device was out of order
6. soft cloth or sponge rub the more heavily stained areas with a soft damp brush after cleaning wipe dry with a soft cloth in case the surface has been stained with ball pen ink lipstick printing ink etc remove the stain immediately by rubbing it with a soft cloth 2 Avoid extensive wetting of the surface of the table 3 Disinfect the upholstery and other surfaces using the Incidin Foam or similar formula available at Meden Inmed 4 Never use cleaning paste wax sprays strong detergents solvents and cleaning agents containing solvents cleaning preparations for natural leather Use of such preparations may cause stiffening and breakages of the cover material as well as adverse change of the glossy finish of the upholstery surface which is not covered by the warranty 5 Sterilization with the use of the UV rays does not affect the surface of the upholstery CAUTION Before starting the cleaning of the table make sure that the electrical power supply cable has been disconnected from the 230 VAC 50 Hz supply in the room 7 2 MAINTAINING MECHANICAL PARTS OF THE STRUCTURE 1 Clean the metal parts with a soft damp sponge Wipe the parts dry immediately after cleaning 2 All movable joints must be lubricated every six months or when experiencing squeaks or other noise We recommend using any available aftermarket lubricants Protect the upholstered parts from contact with the lubricants and remove any excess amounts or leaks
7. ABLE 46cm 54 cm 101 cm Front section elevation angle adjustment from 0 to 40 deg Length of the front section 46 cm Front section depression angle adjustment from 0 to 70 deg Length of the central section 54 cm Rear section elevation angle adjustment from 0 to 85 deg Length of the rear section 101 cm 2 5 THERAPIST M S5 Fx MASSAGE TABLE 46 cm 54 cm 101 cm Front section elevation angle adjustment from 0 to 40 deg Front section depression angle adjustment from 0 to 70 deg Rear section elevation angle adjustment from 0 to 85 deg Length of the front section 46 cm Length of the central section 54 cm Length of the rear section 101 cm 2 6 THERAPIST M S7 Fx MASSAGE TABLE E JE 46 cm 54 cm 101 cm Front section elevation angle adjustment from 0 to 40 deg Font section depression angle adjustment from 0 to 70 deg Rear section elevation angle adjustment from 0 to 85 deg Length of the front section 46 cm Length of the central section 54 cm Length of the rear section 101 cm 2 7 THERAPIST M P3 Fx MASSAGE TABLE 46 cm 54 cm 101 cm Front section elevation angle adjustment from 0 to 40 deg Front section depression angle adjustment from 0 to 70 deg Rear section elevation angle adjustment from 0 to 85 deg Rear section elevation angle adjustment from 0 to 30 deg Length of the front section 46 cm Length of the central section 54 cm Length of the rear s
8. C 50 Hz electrical power supply cable make sure to protect it from accidental clamping objects between moving parts of the table The electrical power supply cable should be laid in such a manner so as to prevent the patient or the masseur from stumbling over it gt 3 After locating the table in its destination place unpack the unit from protective film and insert the power cable plug in the 230 V 50Hz mains socket The table is ready for operation CAUTION Do not use the table in rooms with high relative air humidity especially in rooms meant for hydro therapeutic treatment gt 6 OPERATING THE TABLE Prepare a disposable bed cover such as paper towels disposable sheets etc for each patient before attempting to use the THERAPIST table for treatment procedures especially when using lubricants or other auxiliary substances gels oils talcum powder ointments creams or lotions The patient should wear comfortable underwear and have their body covered for the whole time of treatment except for those parts that are being massaged Following this procedure helps to relax and improve blood circulation prolonging the feeling of warmth in the massaged body parts 6 1 Levelling the table After the table has been located in its destination place it should be levelled This operation is necessary to ensure proper working conditions of the unit After the table has been located in its destination place when resting on its whee
9. THERAPIST User Manual INSTALLATION AND OPERATION MANUAL THERAPIST Massage Table Quality management i system certified by DNV ISO 9001 2008 EM ISO 13485 2003 since 2004 Manufacturer MEDEN INMED Sp ka z o o UL WENED W 2 75 847 KOSZALIN POLAND TEL 48 94 3471040 FAX 48 94 3471041 TABLE OF CONTENTS 1 INTRODUCTION 3 2 FEATURES OF THERAPIST MASSAGE TABLES 4 2 1 USAGE 4 2 2 TECHNICAL DATA 4 2 3 THERAPIST M S2 FX MASSAGE TABLE 5 2 4 THERAPIST M S3 FX MASSAGE TABLE 5 2 5 THERAPIST M S5 FX MASSAGE TABLE 5 2 6 THERAPIST M S7 FX MASSAGE TABLE 6 2 7 THERAPIST M P3 FX MASSAGE TABLE 6 2 8 THERAPIST M P5 FX MASSAGE TABLE 7 2 9 THERAPIST M P7 FX MASSAGE TABLE 7 3 THE DESIGN AND FUNCTIONS OF THE THERAPIST TABLE 8 3 1 COMPONENTS OF THE DEVICE 8 3 2 ACCESSORIES AND AUXILIARY EQUIPMENT 9 3 3 THERAPIST TABLE SET 9 3 4 TRANSPORT AND STORAGE 9 4 SAFETY MEANS 10 5 PREPARING THE UNIT FOR USE 12 6 OPERATING THE TABLE 13 6 1 LEVELLING THE TABLE 13 6 2 HEIGHT ADJUSTMENT RAISING LOWERING OF THE BED 13 6 3 ADJUSTMENT OF THE FRONT REAR SECTION ELEVATION DEPRESSION ANGLE 14 6 4 ADJUSTMENT OF THE FOLD ANGLE OF THE CENTRAL SECTION OF THE TABLE14 6 5 MOVING THE TABLE 14 7 CONDITIONS OF MAINTENANCE 16 7 1 MAINTAINING THE UPHOLSTERY 16 7 2 MAINTAINING MECHANICAL PARTS OF THE STRUCTURE 16 7 3 CHECKING THE GAS SPRINGS 17 7 4 PERIODIC CHECK OF ELECTRICAL SAFETY 17 8 WARRANTY CARD 18 1
10. e a support base for the whole unit with a foot operated height adjustment switch assembly Type FO with two small wheels and two feet Type F4 with four feet and four castors lifted by means of a foot operated lever upper frame a base for the bed top with an electric actuator for height adjustment patient bed allows patients to assume comfortable position for the massage with the possibility of manual adjustment of elevation and depression angles of the front central and or rear sections depending on the type of the table front section with angle adjustment and a breathing hole 3 2 Accessories and auxiliary equipment Each type of the table is provided with a breathing slot in its front section and has rails for fastening the stabilizing belts in the central rear sections Additionally the tables may be equipped with the following accessories stabilizing bolsters wedges 30x40x12 cm and 50x35x20 cm rolls and semi rolls 60x15x15 cm and 60x15x10 cm paper towel hanger for rolls size 60cmx 14cm max ergonomic chair for the therapist remote controller 3 3 THERAPIST table set THERAPIST massage table as per order specs User manual 1 pe Face plug 1 pe accessories as per order specs 3 4 Transport and storage Transport and storage conditions are described in table 1 The Therapist line tables are transported to the customer in a cardboard box on a wooden pallet Stacking
11. ection 101 cm 2 8 THERAPIST M P5 Fx MASSAGE TABLE Er 46 cm 54cm 101cm Front section elevation angle adjustment from 0 to 40 deg Front section depression angle adjustment from 0 to 70 deg Rear section elevation angle adjustment from 0 to 85 deg Rear section elevation angle adjustment from 0 to 30 deg Length of the front section 46 cm Length of the central section 54 cm Length of the rear section 101 cm 2 9 THERAPIST M P7 Fx MASSAGE TABLE 400 je p eg Se 46cm 54 cm 101cm Front section elevation angle adjustment from 0 to 40 deg Font section depression angle adjustment from 0 to 70 deg Rear section elevation angle adjustment from 0 to 85 deg Central section elevation angle adjustment from 0 to 30 deg Length of the front section 46 cm Length of the central section 54 cm Length of the rear section 101 cm NOTE This manual covers all types of the THERAPIST massage tables and not all information and drawings will be relevant to your own massage table The manufacturer reserves to itself a right to apply changes to the product without reducing its functionality or lowering safety requirements 3 THE DESIGN AND FUNCTIONS OF THE THERAPIST TABLE 3 1 Components of the device The frame of the table is made of welded steel sections coated with powder paint It includes the following components Figure I Components of the THERAPIST massage table bottom fram
12. er manufacturer s declaration 2 2 TECHNICAL DATA Table 1 overview of technical parameters of THERAPIST massage tables THERAPIST pozn usar Juss sr wears WOR MATA KIKAKAKIKAKAKM total Technical data cm 202 205 Angle adjustment front section front section 40 70 70 40 70 40 70 40 70 40 70 40 70 70 40 70 70 le om o oa degrees rear section e rear section e 85 30 85 30 30 85 30 30 Height adjustment minimum cm maximum Width of the bed Approx 69 cm JU j j 0 Work cycle continuous brief load 10 max 2 minutes work ON min 18 minutes break OFF Power supply Supply voltage voltage 2380VAC 5OHz VAC 50 Hz and electrical power yes lA security consumption protection level Ambient conditions work 10 C to 40 C 30 to 75 no precipitation 700 1060 hPa relative temperature storage 5 C to 45 C max 75 no precipitation 700 1060 hPa humidity air transport 10 C to 45 C 20 to 95 no precipitation 700 1060 hPa pressure Table 1 Technical parameters of the THERAPIST massage tablees 2 3 THERAPIST M S2 Fx MASSAGE TABLE 46cm 155 cm Front section elevation angle adjustment from 0 to 40 deg Length of the front section 46 cm Front section depression angle adjustment from 0 to 70 deg Length of the central section 155 cm 2 4 THERAPIST M S3 Fx MASSAGE T
13. intained failure to comply with this requirement may result in loss of the user s warranty rights In case the equipment covered by the warranty has been re sold there will be no new warranty document issued No duplicate warranty document will be issued The scope of this warranty does not cover parts and materials subject to normal wear and tear THERAPIST massage table SN Date signature and stamp of the Warrantor
14. ls its feet should stay ca 0 5 cm above the floor including its possible unevenness see paragraph 6 5 6 2 Height adjustment raising lowering of the bed Height adjustment is done by means of a foot controlled frame located at the bottom of the table To lift the table push the frame in the direction of the head rest marked as B in the picture below To lower it push the frame in the direction of the leg rest marked as A in the same picture The table will be lifted or lowered as long as the foot controller frame is kept in its leftmost or rightmost position The actuator switches off automatically when it reaches its minimum or maximum position ar a Figure 3 Control elements of the THERAPIST massage table A lowering B raising C bolster position lock handle 1 a hole for fixing the stabilizing bolsters in the central section 2 two holes for fixing the stabilizing cushion in the front section 6 3 Adjustment of the front rear section elevation depression angle In order to change the elevation depression angle of the front rear section of the table pull the handle of the gas spring lock to disengage it see fig 3 item C set the required position of the section and release the handle to lock the spring again 6 4 Adjustment of the fold angle of the central section of the table In order to change the fold angle of the central section of the table use the control panels located on both side
15. s of the unit to select the required position of the central section see illustration below i i i CAUTION Before using pivoting function bolsters should be removed from mounting holes in front and middle sections of table 6 5 Moving the table 1 Therapist table with the F4 frame type has a foot lever see C in fig 4 which can be set in two positions WORK A with the table resting on its feet which can be adjusted for levelling by screwing the foot in and out see section 6 1 TRANSPORT B with the table resting on 4 castors enabling it to be transported A WORK B TRANSPORT C LIFT LEVER fig 4 Moving the THERAPIST table CAUTION Do not attempt to operate the lift lever with a patient on the table 2 Bottom frame type FO has two feet at the head rest side and two wheels at the opposite side The table can be moved about by lifting it by the head rest be careful not to press the strut lever and transport the table using the two wheels CAUTION Do not attempt to move the table with a patient on 7 CONDITIONS OF MAINTENANCE 7 1 MAINTAINING THE UPHOLSTERY CAUTION We recommend cleaning and or disinfecting the upholstered surfaces and other parts of the tables after each use to ensure proper hygiene level 1 Clean and maintain the upholstered surfaces in the following way clean regularly with warm water and mild detergent e g soap solution use
16. tions which when performed in a way other than described in this manual may worsen the safety conditions or cause hazard to the user and or the operator of the device A similar sign has been provided on the device in places where it is absolutely necessary to follow the instructions provided in this Operation Manual All electric and electronic devices marked with the symbol of crossed out dustbin must be disposed of properly at recycling facilities according to the European Union s WEEE directive or equivalent regulations It is absolutely necessary that all devices which contain substances harmful to the environment R or humans are recycled properly relevant facilities and must not be disposed of with general or household waste Such regulations ensure that the quantity of electronic waste is reduced and a required amount of electronic devices are recycled properly Proper recycling of electronic waste is important as it may contain substances harmful to the environment and humans 2 FEATURES OF THERAPIST MASSAGE TABLES 2 1 USAGE THERAPIST massage tables are designed to be used in therapeutic massage to heal or provide relief in injuries or other impairments by restoring or improving the functions of the massaged tissues organs and systems requirements concerning medical equipment class I rule 12 THERAPIST Massage tables have been manufactured in conformity with essential and are marked with CE mark as p