Home

User Manual

image

Contents

1. Japan Free 1 19 GB Free i Taiwan Figure 3 11 Subscription Control The VSM operator can disable its services to an individual subscriber when subscription expires On the Address Book Figure 3 2 right click one subscriber and select Disable To restore the subscription right click again to select Enable 92 EF Vital Sign Monitor 3 11 Output Alerts When alert conditions occur you can activate the output devices installed either at the VSM site or at the subscriber site Forcing Outputs of VSM To configure output devices at the VSM site click Configure on the window menu and then select Local I O Device Currently the application only supports GV IO modules For setup details see Setting Up I O Devices Chapter 2 User s Manual on the Surveillance System Software CD To automatically force outputs when alert conditions occur see Notification Settings earlier in this chapter To manually force outputs click the I O Device button No 5 Figure 3 1 on the VSM window and then select Force Output to display the Force Output of Local I O Device window Select a desired module and then click Finger buttons to activate outputs Forcing Outputs of a Subscriber See Viewing Subscriber Status earlier in this chapter 93 e GeoUision 3 12 SMS Alerts This feature lets you send out SMS messages to subscribers when alert conditions occur Setting SMS Server Before sending SMS messages to an indivi
2. This feature is only available when the Normal type is chosen The Exit Delay and Entry Delay options are similar to those described in the input trigger Note To set an input trigger for the notification of Normal events see Security Service below o Allow Vital Sign Monitor to Force Output Allows the VSM operator to manually force output devices installed at the subscriber s site Security Service Supports two types of access control systems Momentary and Maintained mode For details see O Device 1 7 Connecting to Center V2 Detecting Input Status The feature is designed to monitor all inputs for a change of state whenever the subscriber starts the VSM monitoring A change from the previously defined state N O to N C or N C to N O will activate an alarm condition Click on the Connect to Vital Sign Monitor dialog box Figure 3 4 For details see Detecting Input Status Chapter 2 User s Manual on the Surveillance System Software CD 89 e GeoUision 3 9 Event Log Browser To launch Event Log Browser click Tools on the window menu and select Event Log Browser This feature is the same as that in Center V2 See 1 8 Event Log Browser Also see Event Log Settings later in this chapter 3 10 Monitoring Subscribers Viewing Subscriber Status To view the subscriber status highlight one online subscriber on the VSM window and then click the View Subscriber Status icon No 9 Figure 3 1 on the tool
3. atime Create atleast one subscriber before starting VSM services To create a subscriber follow these steps 1 On the VSM widow click the Account button No 2 Figure 3 1 to display the Address Book window DE Address Book Xp i Address Book j Telaghore Hi Telephone b l bobil Phone E maili Addres yy Group ri Darta araras OT ar aaas aT a el No 246 Meith Rd Taipei Figure 3 2 2 Click the Add A Group button e to create a group folder 3 o Click the Add A Subscriber button to display the Subscriber Address Book dialog box 4 Enter a login ID and password required Those will be the ID and Password for the subscriber to log in to the VSM See Figure 3 4 5 Enter the subscriber s contact information in the rest of fields optional gt f you wish to send e mail alerts to this subscriber type its e mail address For e mail settings see E Mail Alerts later in this chapter gt Ifyou wish to send SMS alerts to this subscriber type its country code and mobile number For SMS server settings see SMS Alerts later in this chapter 6 Click OK This adds the subscriber to the group folder created before Returning to the VSM window you will see a message Add a subscriber xxx Subscriber xxx has been added 77 e GeoUision 3 5 Creating a Subscription Schedule The VSM operator can create schedules to monitor subscription status When subscribers don t log in the VSM on the programm
4. the VSM window to receive signals from subscribers 3 8 Connecting to VSM To configure GV System in order to access the VSM remotely through a network connection follow these steps 1 Click the Network button and select Connect to VSM This dialog box appears Connect to Vital Sign Monitor serili 1 Password i MW Save Password Login after 30 seconds Monitoring all type events As Exit Advance Figure 3 4 2 Type the IP address of the VSM the User ID and Password created in the VSM See Creating a Subscriber Account earlier in this chapter 3 Click the Connect button Make sure that the VSM is also started for the connection 82 Ea Vital Sign Monitor Advanced Settings for Subscription To further define the communication conditions between the subscriber and VSM click the Advance button on the Connect to Vital Sign Monitor dialog box Figure 3 4 to display the Advanced Settings dialog box There are these tabs on it 1 General 2 Camera 3 System Information and 4 I O Device General The settings define the retry mode and communication port between GV System and VSM Advance Settings General Camera System Information 1 0 Device Connective Port Port Default Connection Broken Maximum Retries Retry Interval 5 4 Seconds MW Retry until connected Figure 3 5 Connective Port Sets the communication port to match that of VSM Connect
5. Chapter 3 Vital Sign Monitor Vital Sign Monitor VSM applies to the center monitoring station where multiple GV Systems are being monitored When alert events occur in a GV System VSM will receive alert text messages computer alarms and or output alarms while a SMS and E Mail message being sent out to subscribers e GeoUision 3 1 System Requirements Before installation make sure your PC meets the following minimum requirements Windows 2000 Windows XP Server 2003 Pentium 4 2 4G 512 MB RAM 60GB NVIDIA GeForce Il 32MB at 1024 x 768 resolution TCP IP 72 a Vital Sign Monitor 3 2 Installing VSM 1 Insert the CMS Software CD to your computer It will automatically run and a window appears 2 Select the Install V 8 0 0 0 Central Monitoring System item 3 Click Vital Sign Monitor System and follow the on screen instructions Note The VSM application is provided with a USB dongle Make sure the dongle is tightly connected to the computer 73 C GeoVision 3 3 The VSM Window 1 hes ta Ber et E H REH a TE EA EE ear ii RE E ie Ea DUNE E YEA PN aka ed La a Pa tee ddd Pe IATE E SER FPH e CES PM UIE si RA A PH La C PM A S T ne NE R e a H EE Ba Pa tee hl PH DLJE Barn PM ti Hehi iihi Pii BERB Era PH mi BEREH kimo PH t iskari iie a pi le AN NFE PEER PE s BEEE G me me a a tae Pe ii Tip ere oer Pata Wiren li kei era Bhen hiar lees haters hea
6. If the subscriber wants the VSM to get notified of the input trigger only when an assigned input is triggered select Normal Right Arrow button Sets the delay time to notify the VSM of the input trigger This feature is only available when the Normal type is chosen Exit Delay While the system is activated this feature provides an interval of time for the subscriber to exit the premises During this time the specified input e g a exit entry door is inactive Once the exit delay expires the input will be fully armed Entry Delay While the system is activated this feature provides an interval of time for the subscriber to entry the premises During this time the specified input e g a exit entry door is inactive so that the subscriber can disarm the system If the subscriber fails to do once the entry delay expires the VSM will get notified of the input trigger Output Module Enables the assigned output module when the selected input module is triggered For this example when the I O Device Module 1 Input 4 is triggered the Output Module 1 Pin 3 will be activated simultaneously Event Type If the subscriber wants the VSM always to get notified of the output trigger select Emergency If the subscriber wants the VSM to get notified of the output trigger only when an assigned input is triggered select Normal EF Vital Sign Monitor Right Arrow button Sets the delay time to trigger the assigned output module
7. Settings Click Configure on the window menu and select Event Log Settings to display the Event Log Settings dialog box The settings are the same as those in Center V2 See Event Log Settings 1 8 Event Log Browser Also see 3 9 Event Log Browser Notification Settings VSM can automatically activate the assigned computer and output alarm to notify the operator while a SMS and e mail message being sent out to subscribers when any of these alert conditions occur 1 Video Lost 2 I O Module Lost 3 I O Trigger Normal 4 I O Trigger Emergency 5 Connection Lost 6 Surveillance System Abnormality 7 Intruder 8 Missing Object 9 Unattended Object 10 Scene Change 11 POS Loss Prevention 12 Disk Full 13 Stop All Camera Monitoring 14 Stop I O Monitoring 15 Subscriber Login 16 Subscriber Logout 17 Login Fail in Surveillance System 18 Start Monitoring All Type Events 19 Stop Monitoring All Type Events 20 Wait Time Expired 21 Unexpected Logout For this application click Configure on the window menu and select Notification to display the Alarm Settings window The settings are the same as those in Center V2 See 1 11 Notification Settings Also see 3 11 Output Alerts 3 12 SMS Alerts and 3 13 E Mail Alert 81 e GeoUision 3 7 Starting VSM After subscriber accounts are created the VSM is ready to provide services Clicking the Start Stop Service button No 1 Figure 3 1 on
8. bar The following window appears Subscriber Status Subscriber VO Device Current De 1 or Enable Disable O Force Output Video Log Storage r 7 AT Camera _ KO Monitoring Recycle Enable EN Camera 1 2 18 Module 1 Last Recycle E Camera 2 a Input _ Camera 3 Input 1 Keep Days 10 _ Camera 4 amp Input 2 Input3 e Input 4 ia Available 1 19 GB 2 48 Output GG Used 124668 g Output HEH e ea Output3 Sb m Output 4 Total Space 13 65 GB Status oe Normal amp Motion Trigger Video Lost oniorr pa Module Lost KJ Monitoring Figure 3 9 90 EF Vital Sign Monitor Subscriber Indicates the subscriber s ID You can change the subscriber by clicking the button Video Log Storage Indicates the information of video log and hard disk space For this subscribers must grant the privilege first See System Information in Figure 3 7 Status Indicates the icon meanings I O Device Force Output To enable this tab highlight one output from the tree list and click this tab to force the output at the subscriber site For this the subscriber must grant the privilege first See the Allow Vital Sign Monitor to Force Output option in Figure 3 8 a Enable Disable I O Allows the VSM to arm or disarm any I O devices at the subscriber site without interrupting the monitoring For this the subscriber must grant the privilege first See the Allow V
9. condition to notify the VSM To configure these settings first disable the Monitoring all type events option in Figure 3 4 Advance Settings General Camera System Information 1 0 Device 1 0 Device Module 1 v V Allow Vital Sign Monitor to Enable Disable 1 0 Input 1 f gt MW Notify Vital Sign Monitor when 1 0 is triggered Event Type Normal l D V Output Module Mod 1 l Pin 1 l Event Type Normal D Output 1 KIZ MV Allow Vital Sign Monitor to force output Security Service Momentary Mode MW Start monitoring normal events when the selected pin is triggered Mod 1 l Pin 1 Mod 1 Pin 1 Maintained Mode Figure 3 8 I O Device Notifies the VSM when I O devices are triggered Use the Arrow buttons to configure each I O device or click the Finger button to apply to all I O devices o Allow Vital Sign Monitor to Enable Disable I O Allows the VSM manually arm disarm any I O devices at the subscriber s site without interrupting the monitoring 87 e GeoUision 88 For example when an alarm is triggered at the subscriber site the VSM operator can turn it off remotely before arriving at the site Meanwhile GV System still remains on monitoring Notify Vital Sign Monitor when I O is Triggered Notifies the VSM when any selected input is triggered Event Type f the subscriber wants the VSM always to get notified of the input trigger select Emergency
10. d rt io lkesi ra M sa kameri Wien iaar ion tes ilkesini tess tees ibien Mht aare ees en A Figure 3 1 The controls on the VSM window 1 Start Stop Service Starts or stops the VSM service 2 Account Adds deletes or modifies subscribers 3 Show Hide Subscriber Shows and hides the Subscriber List List 4 View Event Log Launches Event Log Browser 5 Force Output Activates manually output devices to alert the VSM operator 6 View Subscriber Accesses the subscriber s storage and Information monitoring information 74 ID 8 View Subscriber Address Book 9 View Subscriber Status 10 Send E Mail 11 Send Short Message 12 Flag 13 ID 14 Type 15 Message 16 Message Time 17 Start Time 18 Subscriber List 19 Event List FI Vital Sign Monitor Enter an ID for further search Enter an ID and then click this button to view the subscriber s address book Enter an ID and then click this button to see the subscriber s status Sends e mails to subscribers Sends SMS to subscribers Flags an event for later reference Indicates the subscriber s ID Indicates the event types including System Connection Login Logout Motion Trigger and Alarm Indicates associated information for each event type Indicates the VSM s time when receiving the event message Indicates the subscriber s time when sending out the event message Displays all created groups and subscribers Righ
11. dual subscriber you need to define SMS Server correctly Click Configure on the window menu and select SMS Setup For setup details see 1 72 SMS Alerts Sending SMS Once the connection between the SMS Server and VSM is established there are several ways to send out SMS messages to subscribers See the VSM window for the following selections 1 Click the Send Short Message button No 11 Figure 3 1 This sends out SMS to an individual subscriber manually 2 Onthe Event List double click any event type to call up a message window and then click the Send Short Message icon This sends SMS to an individual subscriber manually 3 On the Subscriber List No 18 Figure 3 1 right click one subscriber and select Send Short Message This sends SMS to an individual subscriber manually 4 Click Configure on the window menu and select Notification to display the Alarm Settings window Check Send SMS Alerts This sends SMS to subscribers automatically when alert conditions occur See Notification Settings earlier in this chapter 94 a Vital Sign Monitor 3 13 E Mail Alerts You can send e mails to subscribers when alert conditions occur Setting Mailbox Before you can send e mails to a separate e mail account you need to define your mailbox correctly Click Configure on the window menu and select E Mail Setup For setup details see 1 13 E Mail Alerts Sending E Mail There are several ways to send e mail alerts See t
12. ed time the operator and subscribers can get notified 78 To set up a schedule see 1 4 Creating a Subscription Schedule When a subscriber doesn t log in the VSM on time this message will appear on the Event List Subscriber session is not established Wait Time expired When a subscriber logs out suddenly during a service time this message will appear Unexpected logout before subscriber session is completed To activate the computer and output alarm to notify the operator while a SMS and E mail message being sent out to a subscriber use the Notification feature For details see Notification Settings later in this chapter EF Vital Sign Monitor 3 6 Configuring VSM On the window menu click Configure to see these options 1 System Configure 2 Password Setup 3 Event Log Settings 4 Notification and 5 Local I O Device These options are discussed in this section System Configuration Click Configure on the window menu and then select System Configure to open this dialog box F System Configure Startup Auto Run when Windows Starts Start Service when Vital Sign Monitor Starts Login SMS Server when Service Starts Connective Port o oreu Camera Motion Fost Motion 10 Second 30 Minute Security Enhance network security Figure 3 3 79 e GeoUision Startup Auto Run when Windows starts Automatically runs VSM at Windows startup o Start Service when Vita
13. he VSM window for the following selections 1 Click the E Mail button No 10 Figure 3 1 This sends the e mail to an individual subscriber manually 2 On the Subscriber List No 18 Figure 3 1 right click one subscriber and then select Send E Mail This sends the e mail to an individual subscriber manually 3 On the Event List double click one event to call up a message window and then click the e mail icon This sends the e mail to an individual subscriber manually 4 Click Configure on the window menu and select Notification to display the Alarm Settings window Check Send E Mail Alerts This sends e mails to subscribers automatically when alert conditions occur See Notification Settings earlier in the chapter 95 e GeoUision 96
14. ion Broken Specify the number of retries and the retry interval when the connection is not immediately available 83 e GeoVision Camera The settings define which camera condition to notify the VSM To configure the even type first disable the Monitoring all type events option in Figure 3 4 Advance Settings General Camera System Information 1 0 Device Camera i Wolly Vial Sin Kir when Maion Belecied __SetCamerals _ Event Type Emergency MW Notify Vital Sign Monitor when the following events come up Intruder Missing Object Unattended Object Scene Change Event Type Emergency Figure 3 6 84 EF Vital Sign Monitor Notify Vital Sign Monitor when Motion is Detected Notifies the VSM when any selected camera detects motion Click the Set Camera s button to select desired cameras for the application Event Type Ifthe subscriber wants the VSM always to get notified of motion detection select Emergency If the subscriber wants the VSM to get notified of motion detection only when an assigned input is triggered select Normal Notify Vital Sign Monitor when the following events come up Notifies the VSM when any alert event occurs including Intruder Missing Object Unattended Object and Scene Change Event Type Ifthe subscriber wants the VSM always to get notified of these alert events select Emergency If the subscriber wants the VSM to get notified of these alert events o
15. ital Sign Monitor to Enable Disable I O option in Figure 3 8 Viewing Storage Information With the above Subscriber Status window you can see one subscriber s storage information When the VSM is monitoring many subscribers the following windows give you an overview of subscribers storage information and monitoring status On the VSM window click the View Subscriber Information button No 6 Figure 3 1 to display the following window 91 e GeoUision Monitoring Indicates whether camera and I O monitoring are enabled at the subscriber s sites Subscriber Information Storage Monitoring Page 1 gt Subscriber List China France German India agi Group C Cameras Monitoring C Cameras Monitoring C Cameras Monitoring C Cameras Monitoring i Chin it a CrO Monitoring LU MO Monitoring C O Monitoring LU VO Monitoring France German Japan Taiwan UAE UK India C Cameras Monitoring Cameras Monitoring C Cameras Monitoring C Cameras Monitoring i Japan cI SEN L MO Monitoring VO Monitoring CIO Monitoring MO Monitoring Figure 3 10 Storage Indicates the total storage size and free space at the subscriber s sites For this subscribers must grant this privilege first See System Information in Figure 3 7 Subscriber Information ubscriber List France German Gat Group Total Total China Free Free i France German Taiwan UAE India Total 13 65 GB Total
16. l Sign Monitor starts Automatically starts the service when VSM starts m Login SMS Server when Service starts Automatically logs in the SMS Server when the VSM service starts You will be prompted to enter the related information of the SMS server Connective Port Sets the communication port to match that of the subscriber or keep it as default To automatically configure the port to your router by UPnP technology click the Arrow button For details on UPnP see UPnP Settings Chapter 6 User s Manual on the Surveillance System Software CD Camera Motion Post Motion Specify the duration of the highlighted text for the incoming message upon motion detection Alerts Interval Enable and specify the interval between the incoming messages upon motion detection Enhance network security Enable to enhance Internet Security Please notice when this feature is enabled the subscribers using earlier version than version 7 0 cannot access the VSM any more Password Settings You can set an administrator password to prevent others from changing your settings by accident Click Configure and then select Password Setup To start the password feature click Service and then select Logout Administrator Users can still start monitoring but will not be allowed to change settings or stop monitoring To change settings click Service on the window menu and then select Login as Administrator 80 El Vital Sign Monitor Event Log
17. nly when an assigned input is triggered select Normal Note To set an input trigger for the notification of Normal events see Security Service in I O Device below 85 e GeoUision System Information Advance Settings General Camera System Information 1 0 Device Video Audio Log Storage Information MW Allow Vital Sign Monitor to inquire the storage information MW Report the total amount of free storage space to Vital Sign Monitor Report Interval 2 H Hours Adjust Time V Time synchronization with Vital Sign Monitor Loss Prevention of POS MW Send Alert Message to Vital Sign Monitor Figure 3 7 Video Audio Log Notifies the VSM when the duration of the video audio logs is less than the specified days Storage Information Allows the VSM to inquire the subscriber s storage information and get the report of free storage space When this option is enabled you will see the message Free Disk Space xx on the VSM Event List window Adjust Time Enables the time increment decrement of minutes and seconds at the subscriber site to match the time at the VSM Lose Prevention of POS Notifies the VSM when abnormal POS transactions occur Note When the Adjust Time option is checked the function of time synchronization will be activated as soon as the VSM is started up and it will be re activated every 24 hours 86 a Vital Sign Monitor I O Device The settings define which I O
18. t clicking any subscriber can call up a menu to select the control No 8 9 10 and 11 Displays a list of events occurred A list of Types and Messages will be displayed on VSM Type Message Motion Camera xx detected Motion Trigger Module xx Input xx Triggered Module xx Input xx Trigger Resume Connection Camera xx Video Lost Video Signal of Camera xx has resumed Module xx Lost Module xx has resumed to normal Alarm There isn t enough space for recording Connection Lost Multicam Surveillance System has been closed Status change of 75 e GeoUision Login Logout System monitoring cameras on camera xx off camera xx Keep Days xx Alarm of Video Log is lower than xx days Schedule Start Stop An unexpected error occurred in Mulicam Surveillance System Error Code 1 or 2 There is an intruder Missing Object Unattended Object Alert Message of POS Scene Change Login Logout Start End Service Fail to Start Service Stop all camera monitoring Start all camera monitoring Start monitoring all type events Stop monitoring all type events Subscriber session is not established Wait time expired Unexpected logout before subscriber session is completed Note Error Code 1 indicates a codec error Error Code 2 indicates that users can t wri 76 te or record any data due to HD failure or user privilege Bi Vital Sign Monitor 3 4 Creating a Subscriber Account The VSM can serve up to 1 000 subscribers at