User Manual - Models 06-601 & 07-701 - S-CUT
Contents
1. Model 06 601 07 701 Model 06 601 with slitting function Manufacturer ES Equipment AB Medicinaregatan 8A Sahlgrenska Science Park SE 413 46 Gothenburg Sweden ESEQ 09 0053 RA October 2009
2. GUT Sales United States Flynn and Me LLC 305 Dalehurst Dr Henderson NV 89074 702 540 6631 info s cut us com Wwww s cut us com Intended Use The S CUT cutting tool is designed for use on patients in rescue situations as well as emergency procedures in hospitals It is a fast way to remove the patient s clothes or other items to expose injuries without needing to change the patient s position which could inflict further injury or unnecessary pain The material is cut by pulling the S CUT and requires only a small amount of force to cut the most common materials in clothes The cutting action is initiated at a fabric edge For the S CUT 06 601 equipped with the slitting function the fol lowing may apply Normally the cutting would be initiated at the edge of the garment but by using the extendable knife a small slit can be cut in order to reduce the need for an edge Tool Parts fig 1 The tool includes the following parts 1 Knurled screw made of stainless steel 2 Washer made of anodized aluminum 3 Cutting blade made of low corrosion steel 4 Support made of POM plastic 5 Handle made of anodized aluminum 6 Extendable knife made of low corrosion steel 06 601 7 Spring made of stainless steel 06 601 8 Knurled nut made of anodized aluminum 06 601 8 only 06 601 7 only 06 601 only 06 601 l A Weight 170 kg 6 0 oz Length 178mm 7 0 in nt ae aa Tool parts Width 24 mm 94
3. in Page 1 2 User Manual Models 06 601 amp 07 701 User Instructions 1 Make sure the immediate area is free from obstacles such as hoses electrical wires or other equipment which may get damaged or affect the cutting procedure 2 Make sure that the extendable knife 6 will automatically retract to its safe position before cutting Applies to Model 06 601 only 3 Initiate the cutting procedure at an edge and cut with a pulling action A smooth continuous cut should be made from the patients head end and downward 4 As an alternative method to section 3 extend the knife by pressing at its rear end and then cut a slit in the material Make sure that the extendable knife 6 is automatically retracted before proceeding with the normal cutting procedure Applies to Model 06 601 only 5 The circular cutting blade 3 can be rotated by first loosening the knurled screw 1 approximately 1 4 turn Do not touch the edge of the blade while rotating it is very sharp Fully tighten the Knurled screw 1 NOTE For the version with the slitting function loosen the knurled nut 8 slightly before loosing the knurled screw 1 allowing the blade to rotate When finished tighten the knurled nut 8 after tightening the knurled screw Rotate the circular cutting blade 3 regularly in order to make sure the cutting edge will be sharp prior to the next cutting Replace the circular cutting blade 3 when excessive effort is nee
4. when contaminated Repair This product has no customer repairable parts Maintenance Make sure to inspect the tool on a regular basis for cleanliness and damage Prior to every use of the 06 601 make sure that the knife 6 automatically retracts to its safe position Additional Information Save this manual for future reference CE Marking This product is CE marked according to the directive for medical devices MDD93 42 EEC LVFS 2003 11 class1 US Patent 7624507 User Manual Models 06 601 amp 07 701 Spare Parts The circular cutting blade 3 plastic support 4 and the extendable knife 6 are recommended spare parts All other parts can be ordered as replacement parts Parts information S CUT complete tool assembly with slitting knife 06601 06601 S CUT complete tool assembly without slitting knife 07701 07701 Handle 06601 07003 1 pcs Circular cutting blade 06501 06001 1 pcs Washer 06501 06002 1 pcs Knurled screw 06501 06008 1 pcs Plastic support 06601 07014 1 pcs For product 06 601 the following parts will be added Extendable knife 06601 07020 1 pcs Spring 06601 07021 1 pcs Knurled nut 06601 07022 1 pcs Recycling The plastic support should be recycled as hard plastic All anodized parts the handle and the washer and the knurled nut should be recycled as aluminum Glossy parts such as the circular cutting blade the extendable knife and the knurled screw should be recycled as stainless steel
5. ded for cutting if the blade gets damaged or when it has been rotated one full turn The current replacement blades have sectors Clearly marked for ease of adjustment 6 In order to initiate a cut at a heavy seam use the area of the blade shown in fig 2 Removal of the Extendable Knife 1 Loosen the knurled nut 8 2 Remove the spring 7 and the extendable knife 6 Do not touch the edge of the blade it is very sharp Removal of the Circular Blade 1 For Model 06 601 Begin by removing the extendable knife as described above 2 Remove the knurled screw 1 3 Remove the washer 2 4 Turn the tool upside down and let the circular blade 8 fall down by itself If it is stuck use the threaded part of the knurled screw 1 and press gently on the blade Do not touch the edge of the blade it is very sharp 5 Remove the plastic support 4 Installation of the Circular Blade 1 Fit a new blade in to the handle 5 Do not touch the edge of the blade it is very sharp Place the washer 2 on the blade Install the washer and the blade by using the knurled screw 1 Slip the support 4 over the projecting arm the hook fig 3 a A O N Mount the support by pressing it forward The support will slide into place and a click will be heard when it is correctly installed Tip Use a tabletop to press the support Example Turn the tool with the support tip against the tabletop and press the entire t
6. ool downward until the click is heard When mounting the support a tight fit is normal if the tool is new or a new support is being fitted Note Always Blade First during the installation and removal procedure Mount the blade prior to the plastic support and remove the blade before the plastic support is removed Fig 2 Fig 3 Cutting a heavy seam Installation of Plastic Support Installation of the Extendable Blade Model 06 601 1 Fit the extendable knife 6 on the back side of the handle 5 Make sure the guide pin is located in the knife s guide slot fig 4 2 Do not touch the edge of the blade it is very sharp 2 Tighten the knurled nut 8 finger tight only Make sure the extend able knife 6 can be moved up and down easily 3 Install the spring 7 by fitting its small eye into the rear slot of the extendable knife fig 4 1 4 Pull and twist the large eye of the spring 7 in order to position it between the knurled nut 8 and the knife fig 4 2 5 Press the knife forward and make sure it automatically retracts to its safe position Fig 4 Spring Installation Cleaning Disassemble the complete tool Do not touch the edge of the blade it is very sharp Clean all parts mechanically i e by using a brush or similar method with a soap solution and water Disinfect all parts with a 70 alcohol solution and air dry Make it a practice to replace the plastic support regularly or