1. Fa 4 Advanced Mission Extender pe a i Fr pa A Omni Medical Svstems www OmniAMXD com Warranty Warranty Omni warrants its system to the original purchaser against defects in material and workmanship for a period of one year from the date of original purchase Omni will at our option replace or repair defective parts without charge Omni will replace or repair any part found to be defective upon inspection by Omni The purchaser will be responsible for freight to Omni Omni will be responsible for freight via UPS Ground to purchaser after repairs This warranty does not apply in the event of misuse or abuse or failure by the user to maintain the system in accordance with Omni instructions or as a result of unauthorized alteration or repairs Damage occurring during transit is not covered by this warranty No other warranty expressed or implied shall apply and in no event shall Omni be liable for consequential economic damage or consequential damage to property Omni Medical Systems Disclaimer Buyer assumes all risk and liability whatsoever from the installation and use of Omni products Omni products are sold as bodily fluid collection and storage devices and should not be relied upon as protection from bodily fluids exposure to the body clothing or other items such as flight deck Omni assumes no liability for injury loss incidental or consequential damages in the event of an accident Table of Contents War
2. Male Cup The Male Cup is safe sanitary and fits like a flexible althletic cup The non invasive urethane cup has an integrated urine sensor for automatic operation The soft foam ring provides a comfortable fit against the body The cup is reusable at the user s discretion for up to 20 flights or 30 days with proper cleaning Fire Retardent Polyurethane Cup Soft Foam Ring Nomex Hose Medical Grade Medical Grade Covering Latex Free Latex Free Urine Sensors Nomex Covered Hose 12 18 24 Hose Connector Velcro Loop GSA SCU RBP VA DOD IMC 2 10 Female Pad The Female Pad is safe sanitary and shaped to fit like a female sanitary pad The non invasive pad has an integrated urine sensor for automatic operation The pad inflates to provide a leak proof seal between the pad and the body It has a soft non woven fabric cover to provide comfort The pad is reusable at the user s discretion for up to 5 flights or 15 days with proper cleaning Fabric Cover Soft Non Woven SF Comfort k Fire Retardent Leak Proof Nomex Hose Inflatable Seal Covering Nomex Covered Hose 12 18 P4 Urine Sensors Adhesive Strip for Automatic Operation GSA SCU ABP VA DOD IFP 15 16 11 Collection Bag The Collection Chamber Unit Bag is manufactured from durable medical grade urethane It has a standard capacity of 1200mL While not reccomended in an emegency it can withstand up to 2200mL
3. Status Indicator Lights Manual M Push Button The Control Unit is used with the Male Cup or Female Pad Undergarment and Collection Bag to provide aircrew with an automated non invasive in flight bladder relief system Battery Release Latch GSA SCU 10 pop SCU 10 2 M F Charger The battery charger only for use with the AMXDmax recharegreable battery packs It must only be used with the supplied power supply which has an input range of AC100 240V 50 60Hz Battery Status Indicator Light OMC 520 S N VAB01805 Battery status indicator lights e Asolid GREEN light indicates that the battery is charged e Aflashing YELLOW light indicates that the battery is charging e A flashing RED light indicates that the battery needs service pop RBP ECU Batteries DO NOT submerge batteries in water DO NOT leave batteries discharged Standard Rechargeable Battery Fully charged the battery lasts for up to 12 uses within a 12 hour period Long Term Storage Battery must be fully recharged and left charged every 12 months 2 batteries come standard with the Control Unit Kit providing up to 24 horus of flight time GSA SCU RBP pop SCU RBP 2 Optional 9V Battery Pack Sold Seperately Battery pack that uses disposable 9V Lithium batteries Capacity is 2 times that of the standard rechargeable battery DO NOT use the 9V Battery Pack with the battery charger GSA SCU ABP pop SCU ABP 2
4. Control Unit Air Vent Connection Clip Odor Proof Hydro Block Drainage Valve Clockwize to tighten Filled with 2 2L Filled with 1 2L DO NOT OVERFILL THE COLLECTION BAG The Collection Bag has a 1000mL over capacity emergency factor GSA CCU 10 DOD CB 10 2 RU 12 Undergarment The undergarments are used to hold the Cup or Pad in place They should be sized for a snug fit They are made out of 100 cotton and are machine washable Male Undergarment Velcro Strip GSA MG 1 2 pop MG1 2 Female Undergarment mA Velcro Strip GSA FG 1 2 DOD FG 1 2 Male System Overview The Male System consists of the Male Cup Control Unit and Collection Bag and are connected together as demonstrated These are the only compnents required on a mission Additional batteries and bags may be taken as needed Control Unit Battery Indicators Manual M button Release Button Control Unit WI si ADWAXW ARAL INWOsg z Hose Connector Nomex Covered Hose 1271824 Male Cup Replace as needed depending on user s requirements Collection Bag Capacity 1 2 L Replace as needed depending on User s reguirements Drainage Valve Close before use 14 Female System Overview The Female System consists of the Female Pad Control Unit and Collection Bag and are connected together as demonstrated These are the only compnents required on a mission Additional batteries and bags may be tak
5. MXDmax system away from heat humidity or harmful chemicals and avoid long term exposure to sunlight Maintenance Tips Omni recommends that the Male Cup Female Pad Control Unit and Bag are cleaned daily to maintain their functionality Disposal The Male Cup Female Pad and Collection Bag can be disposed of in any trash receptacle 24 Troubleshooting Having trouble Try these simple tips email us at support omnimedicalsys com or call 1 802 497 2253 The Control Unit does not start 1 3 4 Check that the battery is charged by pressing the M button The unit should beep twice and flash battery status indicator lights If the Control Unit does not emit an audible beep or does not display a green light remove the battery and replace with a charged battery If the battery fails to charge please contact an Omni Medical Sys tems service technician The Control Unit doesn t automatically start pumping 1 2 3 Disconnect and re connect the Male Cup or Female Pad connector to the Control Unit The Control Unit should beep twice If the Control Unit does not emit an audible beep press and hold the M button to activate the pump If the user needs to manually oper ate the pump by pushing the M button this indicates the cup or pad is not automatically sensing urine and needs to be replaced If the battery status indicator shows that the battery is charged and the Control Unit fai
6. alified Omni Medical Systems service personnel Refer all servicing to Omni Medical Systems service personnel under the following conditions e When the power supply cord or plug is damaged e If the product does not operate normally contact product dealer e Ifthe product has been dropped or damaged in any way e When the product exhibits a distinct change in performance All servicing should be done by an Omni certified service technician Unauthorized component substitutions may result in fire electric shock or other hazards This product should be kept away from heat sources such as radiators heat registers stoves or other products that produce heat System Components Control Unit Kit Undergarments Male Cup Female Pad Control Unit Kit Kit Contents The USB Flash Drive contains e 1 Control Unit e Manual PDF e 1 Charger e Instructional Video e 2 Battery Packs e Marketing Video e 1 Wall Power Adaptor e AMDXmax Presentation PDF e 1 User Manual 1 USB Flash Drive Battery amp Charger Power Supply USB Flash Drive Control Unit amp Battery iS 7 j A To 2 F 8 lt a fa f A o E AM 6 suite A Ji qf A 3 S f Q AI ATA User Manual LaF we 5 Y 35 B yo G Ar pr bor a Ae N lt i w e t pr GSA CSK DOD CSK 2 M F Control Unit Male Unit Female Unit Hose Valves Sensor Pins Pad Air Valve Bag Release Air Pressure Regulator Module APRM Battery
7. e STARTER KIT SCU RBP VA IMCR 2 COLLECTION UNIT Male Cup SCU ABP VA IFPR 15 1 amp 2 COLLECTION UNIT IFPR 16 1 amp 2 Female Pad CCU 10 CB 10 A COLLECTION CHAMBER UNIT Bag MG 1 MG 1 MALE GARMENT MG 2 MG 2 Size 1 Size 2 FG 1 FG 1 FEMALE GARMENT FG 2 FG 2 Size 1 Size 2 SCU RBP SCU RBP A BATTERY PACK RECHARGEABLE SCU ABP SCU ABP A BATTERY PACK DISPOSABLE Contractor Omni Measurement Systems Inc CAGE CODE 1UW92 Sales contact Sales OmniMedicalSys com TO ORDER Phone 802 497 2253 Fax 802 497 3601 Visit our website at www OmniAMXD com to download and review the AMXDmax PowerPoint presenation introduction amp instructional video Users Manual and component datasheets 2 To re order u please contact Omni Medical Svstems 808 Hercules Drive Colchester VT 05446 Phone 1 802 497 2253 Fax 1 802 497 3601 www OmniMedicalSys com www OmniAMXD com Rev 3 27 2014
8. en as needed Pad Inflation Module Female Pad for Female Pads only Replace as needed Battery Indicators depending on user s Manual M button requirements Control Unit Nomex Covered Drainage Valve Hose Collection Bag Capacity 1 2L lose before use 12 18 24 Replace as needed depending on User s requirements 15 Charging the System The battery pack must be charged prior to the first use It make take up to 2 5 hours Connect a Rechargeable Battery to the Charger Connect the cord from the Power Supply to the Charger A solid GREEN light indicates that the battery is charged os xa B d Ve ss o A flashing YELLOW light indicates that the battery is charging OMC 520 S N VAB01805 A flashing RED light indicates that the battery is completely discharged If it does not change to yellow after an hour the battery may need service OMC 520 S N VAB01805 16 Donning the Male System Feed the hose of the Male Cup through the hole in the inside cup pocket and out through the front of the undergarment Insert the Male Cup into the cup pocket on the inside of the Undegarment Align the foam ring with the large hole inside the Undergarment Fasten the pocket shut with the Velcro strip Attach the hose to the front of the undegarment using the Velcro loop The Cup may also be inserted into the Undergarment while being worn 17 Donning the Male System After the c
9. ls to start pumping please contact an Omni ser vice technician The charger indicator light is not working 1 2 3 Check that power supply is plugged in and is securely connected to the charger Remove and connect the rechargeable battery to the charger If the charger indicator light is not lit please contact an Omni service technician 25 Technical Specifications Control Unit Device Specifications Flow rate Operation charge Environmental Specifications Power Weight Dimensions Maximum Noise Level Rechargeable Battery Device Specifications Chemistry Voltage Capacity Charge Cycles Storage Environmental Specifications Weight Dimensions 1 5 0 1 LPM 10F to 122F 1 2 0 1 LPM above 122F 12 Relief Cycles on one battery 7 6V DC 750mA 3oz PLX 1 22 W X TH 65 dB at 1 meter Lithium Polymer 7 2V 350 mAh 500 See page 24 1 OZ 2 4 L X 1 2 W X 0 5 H Charger for Lithium Polvmer Batterv Device Specifications Batterv Chemistrv Charging Voltage Charging Current Charging Time Dimensions Wall Pack Lithium Polvmer 8 4 V 350 mA 2 5 hours 2 3LX 1 2 w X 5 H Input 100 240VAC 50 60Hz 0 30A Output 12V DC 500mA 26 Reordering The AMXDmax is available direct from Omni Medical Systems GSA GSA VA Contract Number V797P 4055B GSA PTN MFG amp DOD PTN PRODUCT NAME CSK CSK A MALE Specify Male STARTER KIT CSK CSK A FEMALE Specifv Femal
10. ol Unit pump transfering the urine from the cup and into the Collection Bag keeping the user dry At the end of mission pinch the sides of the hose connector and slide it away from the Control Unit 21 Female System Operation The Female System is designed to allow the user to connect the Pad Hose to the Control Unit prior to bladder relief Once connected the Pad will take approximately 30 seconds to inflate creating a leak proof seal Once inflated the system will automatically activate when the user relieves her bladder To connect the Pad Hose to the Control Unit Align Air Hose Connector with clip and slide into place When connected there will be an audible click and the control unit will beep twice The Female Pad will inflate taking approximately 30 seconds to complete When the user begins to relieve her bladder the sensors in the Female Pad automatically detect urine and activate the Control Unit pump transfering the urine from the pad and into the Collection Bag keeping the user dry After using pinch the sides of the hose connector and slide it away from the Control Unit to deflate pad 22 After Mission Male Female y To remove the Control Unit from the Bag press the release button and slide the unit away from the clip Remove battery from control unit and recharge Drain collection bag yi io ats Either dispose of Collection Bag and Male Cu
11. p or Female Pad or clean for reuse See Care and Maintenence pg 24 for Cleaning instructions or visit www OmniAMXD com to view the AMXDmax Instructional Video Care Maintenance and Storage WARNING NEVER SUBMERGE THE ENTIRE CONTROL DEVICE Cleaning 1 Attach all three components Control Unit Cup and Bag of the AMXDmax system together 2 Fill Male Cup or Female Pad with warm water OR a solution of 3 Hydrogen Peroxide The Control Unit should turn on automatically If the system does not automatically turn on press and hold the M button Repeat this process twice 3 Once all the water is pumped out of the Cup or Pad and into the Bag move the Bag around to rinse it on the inside 4 Open the drainage valve and empty the bag 5 REMEMBER TO CLOSE THE VALVE AFTER DRAINING 6 Submerge the connector end of the Control Unit in into warm water DO NOT submerge past the release button 7 Press and hold the M push button for 5 seconds then remove the Control Unit from the water and hold the button for an additional 5 seconds to dry out the Control Unit pump 8 DO NOT USE BLEACH VINEGER OR HEAVY DETERGENTS Storage 1 Short Term Storage Always fully recharge batteries before storing 2 Long Term Storage The batteries must be recharged and left fully charged every 12 months 3 Always store the AMXDmax Control Unit in a dry place with temperatures between OF and 150F 4 38 C 4 Keep the A
12. ranty Important Safety Information Components Control Unit Kit Control Unit Charger Battery Male Cup Female Pad Collection Bag Undergarments Male System Overview Female System Overview Charging the System Donning the Male System Donning the Female System Prepping the System Male Operating Instructions Female Operating Instructions After Flight Care Maintenance and Storage Troubleshooting Technical Specifications Reordering 16 17 19 20 21 22 23 24 20 26 2 Important Safety Information Before using the AMXDmax System in a mission setting familiarize yourself with the components and operation of the system Practice using the AMXDmax in a chair or flight simulator before using it in an aircraft 1P 10 11 Always follow instructions when operating the device The batteries must be fully recharged at least once every 12 months The batteries must be left in fully charged state when they are not going to be used for more than 2 months Do not submerge Control Unit under water Do not use liquid cleaners bleach vinegar alcohol ammonia etc or aerosol cleaners Clean using a warm water or a solution of 3 hydrogen peroxide and a damp cloth Use only the type of power supply provided with the AMXDmax System Do not attempt to service this product yourself as opening or removing covers may damage the device and void your warranty Refer all servicing to qu
13. t suit to capture the hose Ensure that the hose is not kinked crimped or pinched See picture at bottom of Page 18 for reference Once seated in aircraft adjust the pad for comfort and ensure that the sensor is at the lowest point of aircraft seat 19 Prepping the System Press the M push button for 1 second and release to display the battery charge status Reccomended to start mission with fully charged battery 100 80 80 20 Below 20 0 Male Female i 4 Slide the Control Unit onto the Collection Bag clip There will be an audible click when the connection is made The AMXDmaxf with battery weighs less than 4 oz and is considered man or woman wearable Roll the Control Unit up in the Collection Bag and store in an available pocket that is accessible durring flight 20 Male System Operation The Male System is designed to allow the user the option of connecting the Cup Hose to the Control Unit at the begining of flight and remain connected for the mission duration Alternatively the user may remove it from storage and connect it each time he needs to relieve his bladder To connect the Cup Hose to the Control Unit Align hose connector with clip and slide it into place When connected there will be an audible click and the control unit will beep twice When the user begins to relieve his bladder the sensors in the Male Cup automatically detect urine and activate the Contr
14. up has been placed into the boxerbriefs insert the Male Anatomy through the foam ring of the cup while donning the boxerbriefs The boxerbriefs should be a comfortable snug fit to properly hold the Male Cup in place Ensure that the hose can be retrieved through the bottom zipper after donning flight gear After entering the aircraft but before securing the harness retrieve the hose and zip the flight suit to capture the hose Ensure that the hose is not kinked crimped or pinched Once seated in aircraft adjust the cup for comfort and ensure that the tip of the cup is down and between the legs 18 Donning the Female System Pn Prior to use locate the gold sensor in the Female Pad When seated in the ejection seat the Center Gold Sensor MUST BE located at the lowest point The location of the sensor is critical for the AMXDmax System to function properly pee N ereeneena Itis very important that this be determined on the ground prior to flight Place the Female Pad into the undergarment with the hose in the front and to the right Use the adhesive strip located on the underside of the Female Pad to secure it to the undergarment Attach the Hose to Velcro strip on the front of the Female Undergarment Ensure that the hose can be retrieved through the bottom zipper after donning flight gear l After entering the aircraft but before securing the harness retrieve the hose and zip the fligh

Download Pdf Manuals