Home
Formal Report of Project 2: Advanced Multimeter using VHDL
Contents
1. DE2 board and we test it with different values of current and voltage The values displayed are accurate and it can display both positive and negative values when we change the values from the power supply We can measure voltage in the range 29 000 DC volt Power Supply 17 In order to obtain negative voltages we design the power supply such a way that the electrolytic capacitors are connected in the opposite polarity We use four 1000uF capacitors as the main core of the power supply We reverse the polarity when we test them on the breadboard We first use 100uF capacitors but the voltage we obtained is not 15V or 10V We design the power supply by trial and error and finally we settle with four 1OOOUF capacitors We also used MBR150 ND diodes to act as rectifier to convert the AC voltage from power supply to full wave AC voltage The first trial we obtained 10V and 12V We then added 0 01UF capacitors and one regulator to the circuit and finally we obtain the desired negative voltage The polarities of the electrolytic capacitors are checked thoroughly to ensure they were connected properly on the circuit board Ammeter The design we came up with the ammeter is that we use a comparator a multiplexer 10 ohm resistors 1k ohm resistors and 100k ohm resistors In order to obtain the 1 ohm resistor we connect eleven 10 ohm resistors in parallel We obtain 1 03 ohm in our first stage when we connect twelve 10 ohm resistors in paralle
2. The codes compiled and worked well as the DE2 board displayed the values of the power supply and the current correctly and precisely The power supply which was designed and soldered on the circuit board was powered by the transformer and thus connected to the DE2 board We obtained a very accurate negative and positive voltage and were displayed on the oscilloscope The ammeter and ohmmeter worked as well when they were both connected to the DE2 board We added the one ohm resistor to the ammeter in order to obtain a precise and accurate result on the DE2 board The metal box was also fixed and made by our group members who are skillful in mechanics The values displayed on our DE2 board fluctuated every 50ms but still reflected the accurate values We would also have to wait for about 3 seconds for the DE2 board to display the values of the voltage and current accurately The breadboards which we were using also 19 showed some resistance when we designed the ammeter When we designed and built the circuit on the breadboards the current values displayed fluctuates and was sometimes inaccurate We changed the breadboards and finally we obtained the desired values All other designs were perfect and everything worked very well as the DE2 board displayed the values accurately when we were measuring the values of current and voltage 20 Reference 1 Slope integrating ADC DIGITAL ANALOG CONVERSION N p n d Fri 20 Oct 2012 lt h
3. Various other components were then used to convert the AC voltage to DC voltage The negative voltages were then achieved by using different sides of the diode bridge Armed with knowledge of circuit theory our group was successfully able to construct a complicated yet efficient circuit Mechanism Description 1 0 Introduction The advanced multimeter using VHDL AMR is an electrical apparatus most commonly used in electrical engineering AMR can change to different modes which are voltmeter ammeter ohmmeter and beta B calculator It is built by chips soldering on silicon electric circuit boards and run by Altera DE2 board We use VHDL to control the function of the DE2 board Then the DE2 board will send signals to the electric circuit board A black rectangular box encloses all electric circuit boards The DE2 board is put on top of the box The major parts of AMR are e VHDL code e Power Supply e Voltmeter e Ammeter e Ohmmeter e Beta B Calculator e Metal Enclosure Figure 1 Appearance of the Advanced Multimeter using VHDL 2 0 Part by part Description The following is a description of main parts of the advanced multimeter 2 1 VHDL code The De2 board and vhdl has served as a brain of our multimeter It works as counters registers many types of decoders multiplexers drivers range checking module and most importantly state machine Two Way BCD Decoder VHDL OVERVIEW Two Way State Machine Binary to B
4. are then smoothed to perfection The last step is to cut a square window at the side of box for the 40 pin ribbon cable to connect to the Altera DE2 board Different views of the box are shown below Figure 11 Top Front Right Back views of the metal box 3 0 Conclusion 15 We use VHDL to run the DE2 board to control the voltmeter ammeter ohmmeter and beta B calculator circuits The channel to these circuits is switched when we press a button on the board The power supply provides specific voltages for the chips in the circuits Combining these circuits together and putting them all into a black metal box we build the advanced multimeter using VHDL A Set of Instructions 1 0 Introduction An advanced multimeter using VHDL AMR is an electrical apparatus most commonly used in electrical engineering AMR can change to different modes which are voltmeter ammeter ohmmeter and beta B calculator AMR is designed for electrical engineering students to measure voltage current resistance and beta B The set up time for the multimeter is approximately 5 minutes The required materials for using AMR are e A programmed Altera DE2 board e An Altera DE2 power supply cable e A 40 pin ribbon cable 2 0 Step by Step Procedure Using an AMR is divided into 7 steps 2 1 Plug in one end of the power supply cable to the DE2 board the other end to any electric AC power supply of 120V 60Hz 2 2 Plug in one end of the 40 pin ribbon cable
5. to the silicon electric circuit board via the rectangular hole on the right side of the box the other end to the DE2 board JP2 junction 2 3 Press the red button on the DE2 board to turn it on 2 4 Move down the switch on the left of the DE2 board to change it to Run mode 2 5 Press the reset button KEYO 2 6 Press button KEY1 to switch the mode of measurement 16 2 7 Measure voltage by wirel current by wire2 resistance by wire3 beta B by wire4 3 0 Conclusion The procedure can be summarized into 3 parts namely powering up the DE2 board setting the DE2 board to Run mode and pressing button KEY1 to switch the mode of measurement If you have any questions about setting up AMR please contact our technician Kelvin Au via phone to 778 773 9809 or email to kelvinau4413 hotmail com Evaluation of the Complete System A Testing Voltmeter and VHDL We start designing the project by writing our own VHDL code which is essential to the voltmeter The VHDL code contains five states Reset Display count up set sign count down and binary BCD decoding We write our code using Quartus II and compile the code to test if it is working before we run it on the DE2 board We double check the Set Sign state of the state machine to ensure it can display positive and negative values The VHDL code we write compile and then we transfer the program into the DE2 board in Active Serial Programming mode The voltmeter is then connected to the
6. CD Decoder From State Machine Range Check Module 20bit Register Displays Figure 2 Overview of the VHDL code Moore Style State Machine Diagram State 0 Reset and Display e CapacitorReset 1 No Condition Reset UpCounter 1 Reset_DownCounter 0 e Enable UpCounter 0 DecodeDone 1 State 1 Count Up State 4 Decode e CapacitorReset 0 Reset_UpCounter 0 e CapacitorReset 1 Reset_UpCounter 1 Reset DownCounter 0 Reset DownCounter 1 Enable UpCounter 0 e Enable UpCounter 1 e Enable DownCou 0 Enable DownCounter 0 State 3 State 2 Count Down Set Sign CapacitorReset 0 Reset UpCounter 1 Reset_DownCounter 0 e Enable UpCounter 0 Enable DownCounter 0 UpTimer 50ms CapacitorReset 0 Reset _UpCounter 1 Reset_DownCounter 0 e Enable U nter 0 CompOutput Sign No Condition Figure 3 State Machine in VHDL The state machine has five states Reset Display Count Up Set Sign Count Down and Binary BCD Decoding When it is in Resetting state it will reset the integrator by shortening capacitor reset all registers with exception to Down Counter which is reset in Count Up and store the new 5 digit BCD value to register for display This display stores this value until the end of next cycle when it receives a new value In Count Up stage up counter is ena
7. EECE 280 amp APSC 201 Formal Report of Project 2 Advanced Multimeter using VHDL Group B7 Kelvin A Jae Yeong B Amelia C Chao J Rohit S Instructor Dr Joseph Yan EECE 280 Dr Jesus Calvino EECE280 Mrs Debby Altow APSC 201 Submission date Nov 30th 2012 Abstract This report provides the Introduction Mechanism Description A Set of Instructions Evaluation of the Complete System Testing Methodologies Conclusion and Reference of an advanced multimeter using VHDL The multimeter can measure voltage in the range 29 000 DC volts current in the ranges 870 00 DC mili Amperes resistance in the range 10 to 4M ohms and Beta of NPN and PNP transistors with 5 digits display The physical configuration of this multimeter is a black metal box enclosing the electric circuit boards and supporting an Altera DE2 board on top Table of Contents Table of Contents Introduction Mechanism Description e Introduction e Part by Part Description o VHDL code o Power Supply o Voltmeter o Ammeter o Ohmmeter o Beta B Calculator o Metal Enclosure e Conclusion A Set of Instructions Evaluation of the Complete System Reference Bibliography page 3 page 4 page 5 15 page 5 page 6 15 page 6 9 page 9 10 page 10 page 11 12 page 12 13 page 13 14 page 14 15 page 15 page 16 page 17 19 page 20 page 21 Introduction The objective of project 2 was to design build and test a high resolution multimeter compar
8. able in performance to the multimeters available at the UBC EECE laboratories The Altera DE2 board was an integral part of the project as it was used to implement the logic component of our circuit programmed via VHDL and was also utilized for its LED and LCD displays to showcase the functionalities of our multimeter The basic design of the VHDL code was a system to 1 Control the flows of the following states Reset Display Count Up Set Sign Countdown and Binary BCD Decoding 2 Manipulate the four registers to fluctuate between the ohmmeter voltmeter ammeter and the Beta calculations 3 Use the LCD drivers to signal the current state The DE2 board was synchronized with a simple voltmeter circuit which consisted of an integrating operational amplifier comparator multiplexer and relay switches to perform the tasks written in the VHDL code The voltmeter served as a platform in which all the other components relied on The ohmmeter required the voltmeter and was built by providing a constant current of 0 01 mA through the unknown resistor By measuring the voltage across the resistor the value was calculated using the formula R V 0 01mA The ammeter also relied on the voltmeter and was built using a difference and inverting amplifier We as a group also built our Own power source that could provide our circuit with positive and negative voltages The basic building block for the power source was a transformer to step down the AC voltage
9. bled to measure 500ms while DE2 board outputs signal to enable Vin to be passed to integrator after 500ms has passed the counter will signal the state machine to proceed to next state In the state Set Sign the output of comparator from voltmeter circuit is inverted and stored in a latch This value will be used as sign If the output of integrator at this point is higher than ground it means the Vin was negative and vice versa The output of this latch is also passed to the multiplexer on circuit to decide which reference voltage to use or 5v The state machine will stay in the next stage Count Down until the comparator output from circuit is changed either from high to low negative sign or low to high positive sign The Down Counter will be enabled at this stage to measure the time in binary In the final stage This binary value is decoded into BCD The reason we do not count down in BCD to start with is for easier computation of the value 4 bit register is used to hold current mode voltmeter ammater ohmmeter beta 4 push buttons on DE2 board are used to switch between each mode and this register holds the value after the buttons have been released The Range Check is also embedded in the VHDL However it does not take a part of state machine it runs simultaneously The Range Checker receives input from Down counter It compares the value to different ranges according to different modes For example in voltmeter
10. e need to measure NPN amp PNP transistor For both transistors we set the base current Ib to 0 1mA by using a constant current source circuit A variable resistor is used to make an accurate value for the resistor to make 0 1mA Asa transistor can act as a current amplifier Ic is amplified by B times Ib i e Ic f x Ib Then 13 we measure the voltage across the 100ohm resistor Vcl Vc2 in the collector and we will know the current Ic because the voltage display divided by 100 will be the current value from the equation V I x R As Ib is set to 0 1mA so the voltage display is actually showing the beta value divided by 100 The circuit of these two transistors are shown below Figure 10 Schematic Diagrams of Beta B Calculator 2 7 Metal Enclosure The box that is used to enclose our multi meter was bought at Lee s Electronic Store It is then altered using the machines at the machine shop to accommodate the multi meter to 14 our design We first drill six holes on the lid of the box This allows the Altera DE2 board to be held firmly in place at the top of the box There are holes drilled at the front and backside of the box for the necessary wires to flow from the circuit boards and the equipment to the transformer The hole drilled in the backside of the box is made for three wires inside the box to reach out Four separate holes are drilled in the front side of the box each allowing one wire to flow through The holes
11. en wikipedia org wiki Current_source gt e VHDL Altera News N p 2012 Web 02 Dec 2012 lt http www altera com support examples vhdl vhdl html gt 22
12. it compares the value to 1V and 10V and assign one of three ranges depending on this range the location of decimal point and which 5 digits out of originally received 7 digits to display Detailed chart on range checker and range shifter is shown below Mode Value Range Description Decimal Location Displayed Range Decimal Digits Example Voltmeter 0 9 999 Ov 1v 1 4 downto 0 12345 V Voltmeter 10 000 99 999 1v 10v 2 5 downto 1 1 2345 V Voltmeter 100 000 10v 20v 3 6 downto 2 12 345 V Ammeter 0 9 999 0 10mA 2 4 downto 0 1 2345 mA Ammeter 10 000 99 999 10 100mA 3 5 downto 1 12 345 mA Ammeter 100 000 100 200mA 4 6 downto 2 123 45 mA Ohmmeter 0 999 0 999 ohms NONE 2 downto 0 amp EO 123E0 ohm Ohmmeter 1 000 9 999 1k 10k ohms 2 3 downto 1 amp E3 1 23E3 ohm Ohmmeter 10 000 99 999 pai 3 4 downto 2 amp E3 12 3E3 ohm Ohmmeter pe a NONE 5 downto 3 amp E3 123E3 ohm Ohmmeter 1 000 000 1M ohm 2 6 downto 4 amp E6 1 23E6 ohm Beta all values NONE 00 amp 4 downto 2 00123 Figure 4 Chart of the Range Check The last module in VHDL is LCD Driver It acts as a driver to write one of five messages on LCD display Four messages indicate the mode and units and one as a welcome screen The ASCII codes are pre coded into VHDL and message is determined by current mode Figure 5 LCD Display of the DE2 board 2 2 Power Supply In order to po
13. l pera Sr SND 22 Ctri 2 Figure 7 Diagram of the Voltmeter Circuit 2 4 Ammeter We designed the ammeter using two LM 358 chips functioning as a difference amplifier and an inverting amplifier a CD74HC4052 E multiplexer chip and resistors of various values In the first portion of the ammeter the input current is provided to the first LM 358 chip and is amplified by 10 and then inverted obeying the formula Vout Vth Vin Vth is 0 resulting in a negative output The output of the first operational amplifier the difference amplifier goes into the second operational amplifier the inverting amplifier to give a final positive result Since we are intending to change the result from mili amps to mili volts we have incorporated a multiplexer which switches between three different channels selecting three different resistance values made available for the necessary conversion to accommodate for the required range of 2 20 and 200 mA When channel 00 is selected the output voltage will be 10 mV if the input current was 1 mA since our resistor value is 1k ohm Channel 01 and 10 are connected to 10k ohm 100K ohm resistors resulting in outputs of 100 11 mV and 1 V respectively In order to obtain an one ohm resistor we connect eleven 10 ohm resistors in parallel before the difference amplifier The value we obtained was 0 99 ohms which is very accurate in calculating the resulting voltage The schematic design of the ammeter is pr
14. l In our second try we obtain 0 8740hm when we used nine 10 ohm resistors We design our circuit by trial and error and finally we settle to used eleven 10 ohm resistors connected in parallel and the value we obtained is 0 99 ohm which is accurate and close to 1 ohm The 1 ohm resistor is then connected to other parts of the circuit Ohmmeter We design the ohmmeter that it is able to fluctuate between four different ranges 0 to 10 ohms 10 ohms to 20k ohms 20 ohms to 200k ohms and 200k ohms to 2 Mega ohms 18 According to Lab Module 4 we used two IN4148 diodes one transistor and resistors of different values to make a constant current source for the measurement We set the input voltage to be 5V To obtain a constant current source of 0 01mA we tried different values of resistors by trial and error method A lower resistor value was used for the first few trials but the current we obtained was too high So we decided to use a larger value for resistors in order to obtain a lower current We used two 100k ohms and one 47k ohms in total of 247k ohms for Re and 0 47k ohms for Rd We chose the load resistance RL to be 10k ohms The resistors and the diodes were connected to the transistor and finally we obtained a constant current source of 0 01mA Strengths and Weaknesses of the Design We designed the project in a unique way We started preparing the project with writing our own VHDL code which is essential for the voltmeter
15. ovided as below Figure 8 Schematic Diagram of Ammeter 2 5 Ohmmeter We as a group implemented our ohmmeter to fluctuate between four ranges 0 to 9 ohms 10 ohms to19 kilo ohms 20 kilo ohms to 199 kilo ohms and 200 kilo ohms to 2 Mega ohms This process was achieved by creating four different constant current sources for each one of the ranges Armed with a 4 to 1 CD74HC4052E multiplexer the task was fairly simple The current sources were created using the following schematic diagram 12 Figure 9 Schematic Diagram of a constant current source For example to calculate the value of an unknown resistor within the range of 200 kilo ohms to 2M ohms we created a constant current source of 0 01mA We calculated Re from the diagram above using the formula 5 0 7 Re 0 00001 Amps The Re calculated was then calibrated to suite our needs and through trial and error we came up with the Re value of 233 kilo ohms Measuring the voltage across the passive element and multiplying the voltage value by 10000 calculated the load resistance The current source and Re values for the different ranges are given below 1 0 10ohms Current source of 10mA Re value of 23 ohms 2 10ohms to 20k ohms Current source of 1mA Re value of 230 ohms 3 20k ohms to 200k ohms Current source of 0 1 mA Re value of 23k ohms 4 200k ohms to 2M ohms Current source of 0 01mA Re value of 233k ohms 2 6 Beta B Calculator There are two kinds of transistors w
16. ttp www allaboutcircuits com vol 4 chpt_13 8 html gt 2 Www datasheetcatalog com Www datasheetcatalog com 21 Oct 2012 lt http www datasheetcatalog org datasheet stmicroelectronics 1981 pdf gt 3 How Analog to Digital Converter ADC Works Hardware Secrets How Analog to Digital Converter ADC Works Hardware Secrets N p n d Sat 21 Oct 2012 lt http www hardwaresecrets com article How Analog to Digital Converter ADC Works 317 8 gt 4 Current Source Current source From Wikipedia the free encyclopedia N p 14 Nov 2012 Retrieved 20 Nov 2012 lt http en wikipedia org wiki Current_source gt 5 DE2 Development and Education Board User Manual Altera DE Board ALTERA 16 Nov 2012 lt ftp ftp altera com up pub Webdocs DE2_ UserManual pdf gt 6 VHDL ALTERA VHDL N p 2012 10 Nov 2012 lt http www altera com support examples vhdl vhdl html gt 21 Bibliography e Dual Slope ADC Dual Slope ADC N p n d Web 22 Oct 2012 lt http www asdlib org onlineArticles elabware Scheeline ADC ADC ADC Dual Slope html e Slope integrating ADC DIGITAL ANALOG CONVERSION N p n d Web 23 Oct 2012 lt http www allaboutcircuits com vol 4 chpt_13 8 html gt e Irwin J David and R M Nelms Basic Engineering Circuit Analysis Hoboken NJ J Wiley amp Sons 2005 Print e Current Source Wikipedia Wikimedia Foundation 14 Nov 2012 Web 08 Nov 2012 lt http
17. wer up all the chips in our circuit we need to create a power supply We use a diode bridge circuit to step down and rectify the AC voltage from the transformer to get a full wave rectified voltage Then we add a decoupling capacitor to the circuit to reduce the ripple voltage The circuit will produce a constant DC voltage 16V and 5V are required to power up the circuit For 16V we can directly use the rectified DC voltage Using the other side of the diode bridge we can get 16V We make 5V and 5v by using a LM7805 and LM7905 regulator The circuit of the power supply is shown below 16V 5V D1 D7 MBR150 16V Figure 6 Schematic Diagram of Power Supply 2 3 Voltmeter The voltmeter circuit is relatively simple and includes only few chips integrating op amp comparator and a multiplexer and few switches the multiplexer is used to provide reference voltage according to the sign of Vin the 2 switches are used as a multiplexer to choose between Vin and reference voltage since the multiplexer chip is unable to handle more than 10 11 volts The integrating op amp and and comparator as the main part of ADC Also a switch was used to reset the integrator The circuit communicates with the DE2 board to work as a full voltmeter Y VCC C1 VEE C2 Voltmeter Circuit Multiplexer ea saric4052 CH2 vcc VEE vcc VEE Y Y Multiplexer _ Integrator Comparator W cu gt gt LM358 oT LM393N a IN2 Ctr
Download Pdf Manuals
Related Search
Related Contents
2008 Jeep Wrangler Owner`s Manual Bukkit no item drops has - Minecraft fence gate plugin recipe American Dryer Corp. D30 User's Manual Simon XT Quick Operation Guide Vantec LapCool 4 Currículum - Secretaría de Educación Pública Chapter 3 Delta 798LF-PN Installation Guide CAMERON Flow Computer Scanner 2200 Hardware User Manual Copyright © All rights reserved.