1. Adjustable items vary by projector 4 1 2 Export Import CMS file Projector Calibration Pro File Functions Tools Test Pattern Settings Help ecco File Export CMS file to export r Picture Picture 2 Expert Setting 1 Expert Setting 2 Screen Functior Select current adjusted settings to your PC You can use this file to copy picture adjustment settings to another projector Select File Import CMS file to import picture adjustment settings from a saved file to the projector 4 1 3 Keyboard control keybord Control Lo Keyboard Control You can use your keyboard to operate the projector keyboard Wide Sony Corporation All Rights Reserved 2014 Company Sony Corporation During the following procedures whenever a test pattern window appears on the PC screen drag it to the extended desktop of the projector and maximize the window Clicking in the maximized window will reduce the window size again 4 2 Standard Calibration This process provides simple calibration without an external chroma meter or illuminance meter Following the instructions step by step you can adjust Contrast Brightness White Balance and Reality Creation to desired settings 4 2 1 Set Initial Settings for Calibration Choose the picture settings to use before starting the calibration If you want to save the current picture settings before starting calibration
2. Red from Pattern Select Measure the x y value and then adjust by changing the values of Red x y settings or dragging the diagram Interactive a Advanced Color Space Set a target RGB default setting is BT 709 Click next to show Red and then measure x y values Input the measured value for Red 4 Click next to show Green and then measure x y values 5 Input the measured value for Green Sony Corporation All Rights Reserved 2014 19 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 6 Click next to show Blue and then measure x y values 7 Input the measured value for Blue 8 RGB apexes will be automatically adjusted to get desired settings Sony Corporation All Rights Reserved 2014 20 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 4 Other Functions under Tools menu 4 4 1 Advanced Color Correction D Advencad Coc Sra You can adjust Hue Saturation and Brightness for Red Green Blue Yellow Magenta and Cyan Tae 4 4 2 Advanced Panel Alignment Panel alignment for each zone can be adjusted by the software Set values for each zone then transmit Use File Export RCMS file menu to copy adjusted panel alignment settings to your PC Use File Import RCMS file menu to import your panel alignment settings to the projector 3 Note If you have any questions please feel free to contact S
3. Target gamma in Instruction box Measure 100 IRE luminance Input the value in the cell Luminance of 100 Ideal luminance values will be automatically calculated to show on the below box Measure Luminance of 10 and then adjust the by dragging gamma curve with mouse until you reach to the desired luminance Continue the same procedure for 20 to 90 Click finish to complete Gamma adjustment Projector Calibration Pro Version 0 01 Gamma Setting Select Adjust Points 1 Point 10 Points 64 Points Data Transmit and Receive Real Time Transmitting Test Pattern Use PG Test Pattern Adjustment Level Test Pattern Set Gamera Position Th str uct ion En Step 1 Click flext to start Gammma Adjustmen a Target Gamma N L Luminance of 100 t Reset Finish 15 Nov 17th 2014 Sony Corporation All Rights Reserved 2014 16 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 3 5 Advanced White Balance Adjustment Advanced White Balance Adjustment Advanced White Balance Adjustment Step 1 4 3 5 1 P Choose Ta rget Colo r Tem pe ratu re Click Next to start Advanced White Balance Adjustment CIE1976 USC Target Color Temp X z 0313 u 0 198 N ote Color Temp E y 0329 v 0468 The target values are different for laser light source models Set Camera Position 4 3 5 2 Measure 20 Gray to adjust Bias Advanced Wh
4. carefully as a Step 1 default however if you want to increase or decrease Reality Creation you can adjust by changing Resolution and or Noise Filtering See below for images when settings are appropriate and inappropriate Appropriate Inappropriate When Resolution is too high Click OK to close Standard Calibration menu window Sony Corporation All Rights Reserved 2014 Sony Corporation Projector Calibration Pro Version 0 01 4 3 Advanced Calibration Advanced Calibration This advanced mode provides more accurate adjustment Fae Andes n aana Lcr through use of an external colorimeter 2 PC Dynamic Range Check Following the instructions step by step you can adjust 3 Contrast and Brightness Adjustment Contrast Brightness Gamma White Balance 4 Advanced Gamma Adjustment Reality Creation and Color Space at suitable settings 5 Advanced White Balance Adjustment Adjustable items vary by projector 6 Reality Creation Adjustment 7 Advanced Color Space Adjustment 4 3 1 Set Initial Settings of Calibration 4 3 2 PC Dynamic Range Check 4 3 3 Contrast and Brightness Adjustment 4 3 6 Reality Creation Adjustment Operations above are same as Standard Calibration in the section 4 2 13 Issued Date Nov 17th 2014 Sony Corporation All Rights Reserved 2014 14 Issued Date Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 3
5. click Export Before Setting Recommended Values If you don t need to save the settings click Set Recommended Value Without Export 4 2 2 PC Dynamic Range Check Check the Dynamic Range settings of the HDMI or DisplayPort VPL GT100 Inputs to prevent errors during the setting process Follow the instruction steps on the screen See next page for images when settings are correct and incorrect Projector Calibration Pro Version 0 01 6 Nov 17th 2014 Standard Calibration 1 Set Initial Setting of Calibration 2 PC Dynamic Range Check Check 3 Contrast and Brightness Adjustment 4 White Balance Adjustment calibration adjustments Export Before Setting Recommended Values If you would not like to export the current setup please click Set Recommended Value Without Export button Set Recommended Value Without Export PC Dynamic Range Check PC Dynamic Range Check Step 1 Sony Corporation All Rights Reserved 2014 7 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 Black stripe White stripe Correct N Incorrect Incorrect When PC setting is Limited and Projector setting is When PC setting is Limited and Projector setting is Full Full N When PC setting is Full and Projector setting is When PC setting is Full and Projector setting is Limited Limited Brighter than background MN No stripe
6. mask SEE EEE Projector 192 168 0 1 255 255 255 0 PC 192 168 0 5 255 255 255 0 3 3 Launch the Projector Calibration Pro program IP Address Setting Multi Projector Control Test Pattern Resolution Launch the software by double clicking the shortcut Use PC Test Pattern created on your desktop soliorauomkr Reconnect Set the IP address in the Setting gt IP Address Setting a SEL IP Address Se le ie Cancel menu to work with the address set for the projector Sony Corporation All Rights Reserved 2014 4 Issued Date Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 Click Get Device Status to get information Projector Calibration Pro File Functions Tools Test Pattern Settings Help In case of error please connect with the projector by Settings gt Reconnect after reviewing all settings IP Address Setting Multi Projector Control Test Pattern Resolution Use PC Test Pattern Reconnect Sony Corporation All Rights Reserved 2014 5 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 1 General 4 1 1 Menu operation a Projector Calibration Pro File Functions Tools Test Pattern Settings Help Multi Projector Control Mod VPL VW5O0ES A P Agrgps 192 169 0 10 PJI All features of a projector found in the OSD On Screen Display menu can be adjusted from the software using the tabs across the window
7. 1 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 lt Outline gt Equipment Required B Corresponding projectors Functions C Preparation D Functions E Note 1 Equipment Required Software Projector Calibration Pro Sony Projector with LAN port see section 2 for more details PC Laptop with HDMI interface LAN cable HDMI cable Chroma meter IIluminance meter only for advanced calibration Recommended equipment Chroma meter CL 200A Konica Minolta For Gamma adjustment Color space adjustment White balance adjustment luminance meter T 10A Konica Minolta For Gamma adjustment 2 Corresponding Projectors Functions Home Cinema Projector Professional Projector VPL VW1100ES VPL VW600ES VPL VWS5O00ES VPL VW300ES VPL GT100 VPL GTZ1 rrligmen adios no ves we wm wm 1 Firmware version 1 100 and later Corresponding OS Windows 7 32 bit 64 bit Windows 8 32 bit 64 bit Windows 8 1 32 bit 64 bit NET 3 5 SP1 is required to be installed Sony Corporation All Rights Reserved 2014 2 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 3 Preparation 3 1 Install Projector Calibration Pro Double click Setup exe in Projector_Calibr ation_Pro_Verl Projector_Calibration_Pro_Verxxx zip folder to install 001 zip Follow the instructions If you already have an older version installed please uninsta
8. 4 Advanced Gamma Adjustment Gamma Setting Use File Export GCMSS file menu to save adjusted gamma settings to your PC Select Adjust Points 1 Point 10 Points 64 Points Use File Import GCMS file to push your saved eT Real Time Transmitting Trans mit Receive gamma settings to the projector Test Pattern Use PC Test Pattern Gamma can be adjusted in two ways by using external Adjustment Level Test Patten i equipment Instruction A Manual adjustment Step 1 Click Next to start Gammma Adjustment Use test pattern to measure and adjust by dragging the gamma diagram to change the gamma curve Target Gamma nte ra ctive Luminance of 100 Set Target Gamma and input measured values by following instructions of the software Manual adjustment Gamma Setting Select the Gamma Table ae wo feo Select color to adjust Ss 5 S a elect Adjust Points Choose adjustment fineness ei OL Points Data Transit ahd Recetve You can choose 1 point 10 points and 64 points Saas Weasawititen Select Adjustment Level to show test pattern Test Pattern Pepe penetra Measure the luminance and then adjust by dragging Use PC Test Pattern Adjustment Level Test Pattern LH gamma curve with mouse until you reach to the desired luminance Advanced Gamma Adjustment Sony Corporation All Rights Reserved 2014 Company Sony Corporation Interactive Click next to start Select
9. ite Balance Adjustment Click next to show Bias Checker If the Bias Checker image is reddish decrease the Red Bias If the Bias Checker image is greenish increase the Red Bias and Blue Bias If the Bias Checker image is bluish decrease the Blue Bias 20 Gray Sony Corporation All Rights Reserved 2014 17 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 3 5 3 Measure 80 Gray to adjust Gain Advanced White Balance Adjustment Click next to show 80 Gray Step If the Gain Checker image is reddish decrease k 7 Sn eS the Red Gain E If the Gain Checker image is greenish increase the Red Gain and Blue Gain If the Gain Checker image is bluish decrease the Blue Gain 80 Gray 4 3 5 4 Confirm White Balance Adjustment Confirm the overall white balance adjustment and click Finish Sony Corporation All Rights Reserved 2014 18 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 3 7 Advanced Color Space Adjustment Three apexes of color space can be adjusted in two ways a Advanced Colar space Manual adjustment Use test pattern to measure and adjust by changing Red Green Blue x y values Interactive Set Target values and input measured values of Red Green and Blue by following instructions of the software Manual adjustment Advanced Color Space Show test pattern
10. ll it before installing the new one When you use Windows 8 8 1 please activate or install NET 3 5 in advance A If using with a wireless network 3 2 1 Connect the projector to the wireless router with a LAN cable 3 2 2 Enter the IP address of the projector into IP Address Setting Projector Calibration Pro Multi Projector Control Test Pattern Resolution Use PC Test Pattern IP address of the projector is automatically assigned by Reconnect the wireless router L a o IP Address Setting IF Address Ee GE Ee Me Cancel 54 53 ED EA 1D 7D Sel PA Set Back Dat Sony Corporation All Rights Reserved 2014 3 Issued Date Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 B If using a wired connection between the PC and the projector 3 2 1 Connect the PC and the projector with a LAN cable Note if a normal LAN cable doesn t work try a cross LAN cable 3 2 2 Connect the PC to the projector with an HDMI cable to extend the PC desktop to the projector 3 2 3 Set the IPv4 network setting of the projector and Installation PC IPv4 Settin Set the IP address of a projector using the projector ayers ea es mae Subnet Mask 255 255 255 O Default Gateway MAC Address 54 53 ED EA 1D 53 Apply on screen menu Set the IP address of the PC Please set different IP addresses and the same subnet mask for the projector and PC Example IP address Subnet
11. ony counter persons in your region END Sony Corporation All Rights Reserved 2014
12. s Sony Corporation All Rights Reserved 2014 8 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 2 3 Contrast and Brightness Adjustment Contrast and Brightness Adjustment 4 2 3 1 Adjust Contrast Click next to show Contrast Checker If you can see 6 vertical steps of Contrast Checker test 90 92 94 96 98 100 pattern Contrast setting is fine If you cannot see 6 steps please decrease Contrast until they are visible Contrast Checker test pattern 4 2 3 2 Adjust Brightness Contrast and Brightness Adjustment Contrast and Brightness Adjustment Step 1 Click next to show Brightness Checker If you can see 6 vertical steps of Brightness Checker test pattern slightly Brightness setting is fine If you cannot see 6 steps please adjust Brightness until 2 A O aca a If you change the value over 10 points please go back to Senne adjust Contrast because Contrast setting affects Brightness and vice versa Brightness Checker test pattern Sony Corporation All Rights Reserved 2014 9 Issued Date Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 2 3 3 Check Contrast and Brightness with Sample Photos Sample Photo 1 for Contrast check Sample Photo 2 for Brightness check gt J y 43 A 4 2 4 4 Click Finish to complete Contrast and Brightness Adjustment Sony Corporation All Rights Reser
13. ved 2014 10 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 2 4 White Balance Adjustment Whee isin Aja White Balance Adjustment Step 2 4 2 4 1 Adjust Bias Click next to show Bias Checker If the Bias Checker image is reddish decrease the Red Bias If the Bias Checker image is greenish increase the Red Bias and Blue Bias If the Bias Checker image is bluish decrease the Blue Bias Bias Checker test pattern 4 2 4 2 Adjust Gain Click next to show Bias Checker E White Balance Adjustment If the Gain Checker image is reddish decrease the Red Gain If the Gain Checker image is greenish increase the Red Gain and Blue Gain If the Gain Checker image is bluish decrease the Blue Gain tex Met Gain Checker test pattern Sony Corporation All Rights Reserved 2014 11 Issued Date Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 2 4 3 Check final settings Click next to show Full Checker to check the final result White Balance Adjustment Full Checker 4 2 4 4 Click Finish to complete White Balance Adjustment Sony Corporation All Rights Reserved 2014 12 Sony Corporation Projector Calibration Pro Version 0 01 Nov 17th 2014 4 2 5 Reality Creation Adjustment Oe omaa Reality Creation Adjustment Reality Creation settings are adjusted