Home
IPower Control 8 www.LINDY.com
Contents
1. ISIINILO Ye CONNECTION PERFECTION IPower Control 8 User Manual English LINDY No 32652 www LINDY com LINDY ELECTRONICS LIMITED LINDY ELEKTRONIK GMBH FIRST EDITION Januar y 2011 Contents D AOL IN oC e er E m T 3 15 NTOQUCHON ER PE 4 A zi el A mcm 4 2 Package Contents a nern in caidos 4 2 2 Installation and ODGOFAOFEi AL tao 4 AS APP en A ee ae E eT Ne LM LED 4 9 COMING UNATION LS I m T 5 341 Automate Conriguration OY DAS A bcp en 5 3 2 Newtwork Configuration by Software nennen 5 2 9 Gobliguratiorn by Web Inter ace een en ee a recto nde nt de 5 Ai SOBEIANON E UU TM PUE 11 4 1 Operation or Me Qaevice estie oii eec Deb oodd des 11 4 2 Operation via the Web Interface ss 11 4 3 Operation via the Serial Interface VU nennen 11 AS GSP unen O o A 12 Sn A M 13 94 Bootloader Mode nsa e du 133 922 EIIMWAare CAIRN E ELT 133 A S ET 133 9 2 TECH CAD a 133 SP eM REM LM mM ME ere ee 14 User Manual English Safety Notice This device must beonly be instaled and used by qualified personnel The manufacturer assumes no liability for improper use of the equipment damage or injuries This device cannot be repaired by the customer and mustonly be performed by the manufacturer This device contains electrical parts with dangerously high voltages and must not be opened or disassembled The power cables plugs and sockets used with this device must be in good condition whilst the device must only be con
2. including interference that may cause undesired operation WEEE Waste of Electrical and Electronic Equipment Y Recycling of Electronic Products United Kingdom In 2006 the European Union introduced regulations WEEE for the collection and recycling of all waste electrical and electronic equipment lt is no longer allowable to simply throw away electrical and electronic equipment Instead these products must enter the recycling process Each individual EU member state has implemented the WEEE regulations into national law in slightly different ways Please follow your national law when you want to dispose of any electrical or electronic products More details can be obtained from your national WEEE recycling agency Germany Die Europ ische Union hat mit der WEEE Direktive umfassende Regelungen f r die Verschrottung und das Recycling von Elektro und Elektronikprodukten geschaffen Diese wurden von der Bundesregierung im Elektro und Elektronikger tegesetz ElektroG in deutsches Recht umgesetzt Dieses Gesetz verbietet vom 24 M rz 2006 an das Entsorgen von entsprechenden auch alten Elektro und Elektronikger ten ber die Hausm lltonne Diese Ger te m ssen den lokalen Sammelsystemen bzw rtlichen Sammelstellen zugef hrt werden Dort werden sie kostenlos entgegen genommen Die Kosten f r den weiteren Recyclingprozess bernimmt die Gesamtheit der Ger tehersteller France En 2006 l union Europ enne a introduit la nouvelle r
3. HTTP Port T e g http 192 168 0 2 1720 Enable HTML Autorefresh 2yes O no Enable HTML Auto Refresh Sob Rent ham Here you can choose to auto refresh the web a tnt Pigs Mae lie interface des hl adi Require HTTP Password a Login Name Password protected access can be activated here In this case a user and an admin password have to be defined Passwords have Apel a maximum length of 15 characters Administrators are authorized to switch all ports and to modify the settings of the IPower Control and of all ports The username of the admin is admin Users are authorized to switch all ports but are not allowed to modify the settings of either the IPower Control or the ports The username of the user is user If you have forgotten your password activate the bootloader mode of the IPower Control start GBLConf exe and deactivate the password request Password Check Password on start page SE Conaguraton MEER When this feature is activated the password is d checked before displaying the login page This prevents unauthorized persons from seeing the mi DRM m switching status and the labels of the power ports Choose Sensor Port Temperature Auxport Generate Messages yes Ono Maximum Value 0 Generate Messages Minimum Value 0 Here you can configure if and at which Hysteresis Minimum Maximum Temperature the IPower Control shall send temperature alerts via SNMP Traps and ose TE 1 Sysl
4. example monitor TCP port 25 for a standard SMTP server TCP port 80 for a standard HTTP server etc 6 www LINDY com LINDY IPower Control 8 User Manual English Host IP Here you can enter the IP address this watchdog should observe TCP Port If TCP pings are used here you can enter the TCP port A TCP port is not needed when ICMP pings are chosen Ping Interval Here you can enter the time between pings Ping Retry Here you can enter how often the ping should be repeated before a power port will be reset Configuration IP Address Hostname Enter a name using up to 15 characters MN Using special characters may de stabilise your network IP Address Here you can change the IP address of the IPower Spang Control Configuration IP Address Netmask Hostname EPCNET x Here you can change the netmask of the lPower IP Address 19216802 Control Netmask 255 255 255 0 Gateway N9216801 Gateway Use yes C no Here you can change the standard gateway of the p IPower Control Apply Use DHCP Here you can set whether the IPower Control get its TCP IP settings directly from your DHCP server If DHCP is activated the IPower Control checks that a DHCP server is active on your LAN The IPower Control then requests TCP IP settings from this DHCP server If there is no DHCP server available on your network we recommend you deactivate this function Configuration IP ACL Reply ICMP Pi
5. glementation DEEE pour le recyclage de tout quipement lectrique et lectronique Chaque Etat membre de Union Europ enne a mis en application la nouvelle r glementation DEEE de mani res l g rement diff rentes Veuillez suivre le d cret d application correspondant l limination des d chets lectriques ou lectroniques de votre pays Italy Nel 2006 l unione europea ha introdotto regolamentazioni WEEE per la raccolta e il riciclo di apparecchi elettrici ed elettronici Non e piu consentito semplicemente gettare queste apparecchiature devono essere riciclate Ogni stato membro dell EU ha tramutato le direttive WEEE in leggi statali in varie misure Fare riferimento alle leggi del proprio Stato quando si dispone di un apparecchio elettrico o elettronico Per ulteriori dettagli fare riferimento alla direttiva WEEE sul riciclaggio del proprio Stato LINDY No 32652 1 Edition January 201 1 C FC www lindy com www LINDY com LINDY IPower Control 8
6. inlet IEC C20 max 16A Network 10 100 MBit s 10baseT Ethernet Protocols TCP IP HTTP SNMP v1 und v2c SNMP traps Syslog owitched Power total 16 A 3600W Switched Power per port 10 A 2000W Power supply IEC C20 16A 230V AC Operating temperature 0 C 50 C Dimensions 19 1 rack unit Total weight 1 5 kg The device can operate at 10Mbps or 100Mbps By default from the factory it is set to 10Mbps It is recommended that you only change this setting if your network requires it There is no noticeable performance advantage in switching from 10Mbps to 100Mbps as amount of data transferred by the device is very small By setting the IPower Control to 100Mbps it will use more power and operate at a higher temperature LINDY IPower Control 8 www LINDY com 13 User Manual English 6 Support On our website www lindy com you have the latest software on our products for free download For further questions about installation or operation of the IPower Control please contact our support team www LINDY com LINDY IPower Control 8 User Manual LINDY IPower Control 8 www LINDY com English User Manual English CE Certification This equipment complies with the requirements relating to electromagnetic compatibility EN55022 EN55024 class B for IEC EN61000 4 2 3 the essential protection requirement of Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic
7. OND 2 2 Installation and Operation 1 Connect the power supply cable to the power socket 9 at the rear side of IPower Control and a power outlet The Power Control will now boot up and shortly after will be ready for use 2 Plug the Ethernet cable into the connector 6 on the front side of Power Control and connect it to your network 3 Connect the client devices to the active outlets 8 at the rear side of the Power Control 2 2 LED Status The Status LED 3 shows different states of the device e Status LED red Device is not connected to the ethernet e Status LED orange Device is connected to the ethernet TCP IP settings are not allocated e Status LED green Device is connected to the ethernet TCP IP settings allocated device is ready to use e Status LED blinks alternately red and green Device is in Bootloader mode 4 www LINDY com LINDY IPower Control 8 User Manual 3 Configuration 3 1 Automatic Configuration by DHCP English After switching on the IPower Control it will look for a DHCP server and request an available IP address for deactivation of that feature on page 7 Please check the IP address allocated to the IPower Control in the DHCP server settings to make sure that the same address is used after every reboot 3 2 Network Configuration by Software To change the network properties manually the program GBL Conf exe is required This tool is available for free on our website www lindy com Furthermo
8. Serial Interface Alternatively to the ethernet network interface the Power Bits per seconds EDU Ports of the IPower Control can be switched through its hat M serial interface It only requires a terminal program like stop bits 1 HyperTerminal a program provided under Windows for free Flow control none found in Programs Accessories Communication Connect your PC to the Power Control with the PS2 RS232 adaptor cable and plug the device into a power outlet Now you can turn on the IPower Control The boot process takes a few seconds longer than by Ethernet You can access the IPower Control through the terminal program as soon as the status LED lights up green Choose the COM port that is connected to the IPower Control and enter the following values for the serial interface If you do not use HyperTerminal please make sure that the terminal program supports LA VT100 commands LINDY IPower Control 8 www LINDY com 11 User Manual English After connecting successfully the IPower Control answers as shown in figure below Press Enter to login Pe s _ LINDY IFower Control 8 Hyper Terminal Datei Bearbeiten Ansicht Anrufen bertragung Dig 8 3 ole es LINDY IPower Control 8 press ENTER gt kev to login Now the Power Ports can be switched on and off by number keys By pressing c you can check the network configuration and by pressing Esc you can log out LINDY IPower Control 8 Hyper Termina
9. as disabled Host IP 0 0 0 0 TCP Port 80 Watchdog Function While using the Watchdog electrical devices can be observed The Watchdog sends ICMP pings or TCP pings to the device If these pings are not answered during a defined delay time or pings the power port will reset The Watchdog function allows you to restart e g crashed servers or NAS systems You can check the Watchdog function and other information inside the switching menu There are different colours to let you know the status e Green text Watchdog is active and receiving ping replies e Orange text Watchdog is activating at the moment waiting for first ping reply e Red text Watchdog is active and does not receive ping replies any longer When Watchdog is activating it waits for a first ping reply During this time the information is written as an orange text After the receipt of the first ping reply it switches to active written in green letters When Watchdog reset a power port the Watchdog again waits for a first ping reply as stated above Enable Watchdog Here you can activate the watchdog for this power port Watchdog type Here you can switch between ICMP ping and TCP ping ICMP Pings Uses an Internet Control Message Protocol ICMP echo request to the network device such as a server or NAS to check access is possible TCP Pings Using a TCP Ping you can check whether a specific service on the monitored network device functions So you can for
10. compatibility FCC Certification This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced technician for help You are cautioned that changes or modification not expressly approved by the party responsible for compliance could void your authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received
11. e communities without encryption Therefore it is simple to spy out these communities We recommend using a DMZ or IP ACL MIB All information that can be requested or changed Managed Objects are described in Management Information Bases MIBs There are three MIBs which can be requested from the IPower Control system interface and powerports system and interface are standardised MIBs MIB Il powerports was created especially for the IPower Control These three sub structures are called OIDs Object Identifiers subordinate An OID space indicates the location of a value within the MIB tree Each OID can alternatively be denoted by its symbol name name subtree SNMP Traps SNMP Traps are system messages that are sent via the SNMP protocol to different recipients SNMP traps occur for the following events e Switching the power ports e Exceeded max min values of the sensors For the available SNMP options see the section Configuration SNMP LINDY IPower Control 8 www LINDY com 9 User Manual Configuration SNMP Trap Receiver List Enable Traps Here you can activate SNMP Traps If enabled the IPower Control will dispatch SNMP Traps to all of the listed recipients Recipients have to be listed as follows IP address and if necessary the HTTP port e g 192 168 0 2 8000 Trap Version Here you can choose between SNMP vi and v2c standards for the type of SNMP Trap you want to send Confi
12. guration Syslog Enable Syslog Here you can enable the Syslog function Syslog Server IP If Syslog is enabled enter the IP address of your Syslog server Syslog Port If Syslog is enabled enter the port number that your Syslog server uses to receive syslog information Syslog English Configuration Logout Power Ports IP Address IP ACL HTTP Messages SNMP Syslog Config Traps Configuration SNMP Trap Receiver List Enable Traps U Trap Version Ovi Ovzc OY M wn Configuration Power Ports IP Address IP ACL HTTP SNMP Syslog Configuration Syslog Enable Syslog yes no Syslog Server IP Syslog Port 51 4 Apply oyslog messages are simple text based messages transmitted to a syslog server using UDP Linux OS generally have a syslog daemon installed e g syslog ng For Windows there are freeware tools available On following events the IPower Control will send a syslog message e Booting up e Activation deactivation of syslog e Switching of Power Ports 10 www LINDY com LINDY IPower Control 8 User Manual English 4 Operation 4 1 Operation of the device The IPower Control offers two buttons for control select and ok By pushing select the LED of Power Port 1 status select ok starts blinking which means that it is selected By pushing the button again the next Power Port is selected and so on lf you want to change
13. l Dabei Bearbeiten Ansicht Anrufen bertragung 7 Die sid ols el LINDY IPower Contral 8 1 ON Power Port 1 lt 2 gt ON Power Port 2 lt 3 gt OFF Power Port 3 4 ON Power Port 4 lt o gt ON Power Port 3 lt b gt OFF Power Port 6 lt ON Power Port 8 OFF Power Port 8 press lt 1 gt lt 8 gt to toggle port 1 8 press lt z gt for configuration menu press lt ESC gt to logout 4 4 Sensor Connect the temperature sensor with the TEMP and AUX connector at the front of the device Once it is connected correctly the recent temperature is displayed in the login window in the switching window and can be requested via SNMP The sensors temperature sensor and hybrid sensor for temperature and humidity can be purchased as an accessory from us More information can be found at www lindy com or you can contact our sales team Technical Data for Sensors Temperature Sensor Cable Length 2m PS 2 10 C to 70 C at 2 C maximal and 1 C typical Temperature Humidity Hybrid Sensor Cable Length PS 2 40 C to 80 C at 0 5 C 0 100 3 12 www LINDY com LINDY IPower Control 8 User Manual English 5 Features 5 1 Bootloader Mode To activate the bootloader mode of the IPower Control press the select button while restarting the device In bootloader mode it is possible to disable password protection to update the firmware and to restore the default settings by
14. line of your internet browser http IP address of the Power Control and press LOGIN LINDY IPower Control 8 www LINDY com Mi Power Port 1 M Power Port 2 MA Power Port 3 EB Power Port 4 M Power Port 5 MP Power Port 6 M Power Port 7 We Power Port 8 Cuan Temp por 1002 7240 24h mes mo Temp port 007 AI 24h mines mad se Cunrent tree D he i eee User Manual English To enter the configuration menu click on Configuration on the upper left side of the screen Configuration Power Ports Label Control Pane Configuration Logout A name with a maximum of 15 characters Power Ports IP Address IPACL HTTP Messages SNMP Syslog can be entered here for each Power Port Configuration Power Ports After power up switch Choose Power Port 1 Power Port1 Y The Power Ports switching state after a power on of the lPower Control can be Label Power Port 1 defined here on off remember last state AS HE If switching on after power up wait 0 seconds before switching If switching on after power up wait A switching delay of a Power Port can be AE SELTEN defined here that is applied after switch on of the IPower Control The delay can last up to 8191 seconds Enable watchdog 9 off O on Watchdog type ICMP TCP After turning off wait When this feature is activated the Power Port turns on automatically after a Ping Inte TE Pina rivis predetermined time since it w
15. nected directly to a mains power outlet with adequate grounding which provides power at 230 volts AC 50 or 60 Hz This equipment is intended for indoor use only It should not be used in damp or excessively hot areas Please notethe safety instructions in this manual Please note also the safety and operating instructions of the other equipment that are connected to the device This device is not a toy It must not be kept or operated within the reach of children Packaging material can be dangerous and must also be kept away from children LINDY IPower Control 8 www LINDY com 3 User Manual English 1 Introduction Using the LINDY IPower Control 8 electrical devices can be switched via a TCP IP network There are only two steps necessary for installation The connection to an electric circuit and a TCP IP network followed by the configuration of the IP settings Afterwards the LINDY IPower Control 8 can be switched by all PCs on the network 2 Hardware 2 1 Package Contents LINDY IPower Control for 19 Installations Power Supply Cable User Manual CD ROM with Software Front view of the IPower Control 1 23456 7 Rear view of the IPower Control LED indicators for power ports OK and Select buttons Status LED Auxiliary port for serial adapter cable or sensor Port for Temperature sensor Network port RJ45 Display 8 Power Out Ports IEC C13 max 10A Power In Port IEC C20 max 16A Ron
16. ng requests Power Ports IP Address IP ACL HTTP SNMP Syslog Here you can set whether the IPower Control shall react on pings Configuration IP Access Control List Reply ICMP Ping requests M Enable IP Filter Enable IP Filter 1 Here you can activate the IP Access Control List IP ACL of the IPower Control If IP ACL is active DHCP and SNMP only work if all necessary servers and clients are registered in this list 1 2 3 4 5 B iy 8 Apply LINDY IPower Control 8 www LINDY com 7 User Manual English IP Access Control List The IP Access Control List ACL IP is an IP filter for the IPower Control When the filter is active only the hosts and subnets whose IP addresses are registered in the list can contact the IPower Control to change settings and switch the power ports Example Entry in the IP ACL Access 192 168 0 123 e with the IP Address 192 168 0 123 can access the 192 168 0 1 24 Fr on the subnet 192 168 0 1 24 can access the If you are here locked out by mistake select the bootloader mode of the Power Control and turn off the IP ACL using the GBL Conf exe Configuration HTTP HTTP Port Here you can enter the HTTP port number if ome Gonfguration Logeu necessary Possible numbers are 1 65534 UI AL AL E A HS SE standard 80 To get access to the lPower Control you have to enter the port number Configuration HTTP behind the IP address of the IPower Control
17. og Apply 8 www LINDY com LINDY IPower Control 8 User Manual English Configuration SNMP Enable SNMPget Here you can set whether the IPower Control should be addressed over the SNMPget protocol Power Ports IP Address IPACL HTTP SNMP Syslog Config Traps Configuration Community public Define the SNMP Working Group Configuration SNMP Enable SNMPset Community pub SER Here you can set whether the Power Control should be addressed over the SNMPset protocol Enable SNMP set C yes no Community private private omm P Download SNMP MIB p Define the SNMP Working Group Sent Download SNMP MIB Here you can download the MIB to query and control the IPower Control with SNMP SNMP You can use SNMP to get detailed status information from the IPower Control via UDP port 161 In addition you can use SNMP to switch the power ports Supported SNMP commands e SNMPGET Request status information e SNMPGETNEXT Request the next status information e SNMPSET Request change of status You will need a Network Management System e g HP Open View OpenNMS Nagios etc or the command line tools of NET SNMP to request information of the IPower Control via SNMP SNMP Communities SNMP authenticates requests by communities The public community has to be added to SNMP read requests and the private community to SNMP write requests You can see the SNMP communities like read write passwords SNMP v1 and v2 transmit th
18. re GBL Conf exe enables you to install firmware updates and to reset the lPower Control to its factory settings see page 14 Activate the bootloader mode of the lPower Control and run GBL Conf exe see page 14 The program will look automatically for connected devices and will display their network configuration If the displayed IP address is the factory setting 192 168 0 2 there is either no DHCP server available in the network or no free IP address could be allocated Enter a free IP address and the according netmask in the entry mask then save these changes by clicking on Program Device SaveConfig Search LaunchBrnwsar ProcravGevos pions 7 BealLasmde Veron 23 GEL wt Claire Fimevare Version 1 2 Hozi OS Windows 2000 Version 5 0 Build 7195 GEL Conf asa 1 25 zeerchng dences plesce wal 1 devices found TH ghuork Configuration MAL Addrers IP Address o1 392000114 1221 EB Helm az Gober 255 255 255 0 3216801 Use HTTP password HITF Fuit M TCP IP Setingr by DHCP 82 7 Erab IF ACL 7 GEL serial debug C AueMeg S Menud Re 10mbk 1Onbt f Curent Link 10rmbit hal dupl poer ux Restart the Power Control by switching it off and on again so that the changes will take effect Now click on Search in order to have the new network configuration displayed 3 3 Configuration by Web Interface Go to the website of the IPower Control by entering the IP address of the IPower Control into the address
19. running the program GBL Conf exe If the device runs already press and hold the select and ok buttons for three seconds The bootloader mode of the IPower Control is indicated by BOOT LDR appended to the device name in the program window of GBL_Conf exe To restart the firmware without toggling the Power Ports press and hold the select and ok buttons for three seconds again 5 2 Firmware Update In order to update the firmware GBL Conf exe and the latest firmware are needed otart the device in bootloader mode and run the program GBL Conf exe On the left side of the program window all IPower Control devices that are in the network are listed Select the device that should be updated click on Program Device Firmware Update and specify the location of the new firmware Please note that the current version of the firmware and the program GBL_Conf exe are available for download from www lindy com 5 3 Factory Reset You can roll back the IPower Control to Factory Default settings at any time using the software GBL Conf exe To complete the reset and therefore delete all the settings you have entered please take the following steps Enable the boot loader mode of the device e Select the device in the software GBL Conf exe e Select Program Device Reset Settings to Fab e Disable now the boot loader mode 5 4 Technical Data Connections 1 x Ethernet RJ45 2 x PS2 Connector 8 x Power Ports IEC C13 max 10A 1 x Power supply
20. the switching state of the selected Power Port push the ok button for two seconds TOMO You can check the status of the Power Ports by the colour of the Power Port status LED green enabled red disabled 4 2 Operation via the Web Interface Switching Go to the website of the IPower Control by entering the lll Power Port 1 IP address of the IPower Control into the address line of lll Power Port 2 your internet browser Wl Power Port 3 EM Power Port 4 http IP address of the IPower Control and press Wl Power Port 5 LOGIN NS Power Port 6 NS Power Port 7 Now you can switch directly The current switching M Power Port 8 state of the power ports is presented visually red off on green In the lower part of the switching window m you can see the current flow and the peak current If PAR Moon vates you have connected a temperature sensor or a hybrid sensor you will see the sensor readings here as well Batchmode contorraner LL EE Each individual power port of the IPower Control can be set for a selectable period of time 1 30 seconds or 1 30 minutes in the state switch on or switch off After the selected time period it will automatically ok switch to the predetermined condition Switching Batchmode Switch 1 Power Port 1 x of wait 5 sec y switch on y Alternately the device can be switched as required via a Perl script or external programs 4 3 Operation via the
Download Pdf Manuals
Related Search
Related Contents
SISRAMAL – MANUAL DE INSTRUÇÕES – LOG IN golden spot 1200 hmi 1200w/s Rheem High Efficiency - ECM Motor - Standard N Coil Sales Fact Sheet 修理お取扱いについてのお知らせ Installation Breville VIN209 iron MT 2.11.03 Air Cooled Scroll Chiller Service Manual (T1/R407C/50Hz) KRAM 78951 mounting kit Copyright © All rights reserved.