Home

"user manual"

image

Contents

1. Do not attempt to open the upper housing cover and modify otherwise may cause danger of burn For adult use only Hazer must be installed out of the reach of children Never leave the unit running unattended Position the Hazer machine in well ventilated area Please leave about 20cm spaces surrounding the machine Never aim the machine at open flames or close to flammable items Never add flammable liquids of any kind oil gas perfume to the Hazer liquid ENT f DA Use only dealer recommended SGM high quality Hazer liquid HZL Please do not use any other liquid which may cause erosion of inner parts If your SGM Hazer fails to work properly discontinue use immediately Drain all Hazer liquid from the tank pack the unit securely preferably in the original packing material and return it to your SGM dealer for service Please note before sending the machine for transporting purpose make sure the liquid inside the tank is fully emptied Never drink Hazer liquid If it is ingested call a doctor immediately If Hazer liquid comes in contact with skin or eyes rinse thoroughly with water IMPORTANT Pay attention to all warning labels and instructions printed on the exterior of your SGM Hazer 3 UNPACKING amp INSPECTION Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact Before beginning initial setup of your SGM Hazer make sure that there is no
2. OTHER THAN SGM FOG FLUID WILL VOID WARRANTY 6 Hazer 400
3. Thumb Screws Nozze Output Blade Liquid Level Indicator SGM Hazer 400 machine produce safe dry clean and virtually invisible Hazer when used with HZL 1 Hazer liquid with an extremely long hanging time For ideal results Hazer when touch up is needed Hazer 400 3 GB SGM 6 CAUTION 1 Always monitor and make sure that there is sufficient HZL liquid inside the tank during operation 2 Pour Hazer liquid into the liquid tank about 1 2 full be careful not to exceed the maximum fluid level DO NOT OVERFILL The extra 1 2 tank space is reserved for air flow purpose Overfilling will cause the unbalance in air pressure which will affect the Hazer liquid to flow back to the compressor and may lead damage of the compressor unit 3 When the machine is operated for a longer period of time under open air conditions falling dust debris can enter the machine and may create residue inside the muffler of the compressor It will clog the filtration fibre on the muffler Contact an authorized SGM dealer to replace a new muffler only please note that the old muffler is unable to use repeatedly after washing or brushing Long term use of the unit which has the build up residue on the muffler may cause an unsteady operation of the compressor It may even cause danger of burn under serious conditions Compressor Muffler 4 If you have followed the above operation steps and you still experience low output mechanical noise or no output at all unp
4. N control knob HCR 1 Wireless remote controller with 14 stereo plug for SGM Hazer 400 Attach the receiver s magnetic base to the Hazer Plug the receiver s cable into the Hazer s remote control input Using the sending unit your SGM Hazer can be operated from a distance at least 50 meters when under no obstruction Start Hazer emission by pressing the small button on the sending unit Stop Hazer emission by pressing the large button Multiple SGM Hazers may be controlled using only one sending unit The control of the master unit will override all other controllers when connecting the Hazer machine via DMX 8 DMX OPERATION The units HZ 300 and HZ 400 have on board DMX control These models use 1 channel to control volume output operation Each channel has a value range of O to 255 The DMX channel is set on the rear panel of the HZ 300 and HZ 400 by setting the dip switches to the desired channel If Channel A has a value from O to 5 the unit is OFF Between the values 6 to 255 the volume of fog output is regulated With 6 being the minimum volume of fog produced and 255 approaching the maximum The volume output rises as the DMX value is increased Note The controls HC 1 and HCR 1 will be disabled when the Hazer is in DMX mode DMX DIP SW Pos 67255 OF a SW12345 67 8 9 Hazer 400 5 GB SGM 9 HAZER LIQUID SGM HZL 1 Hazer liquid was designed for the use with SGM Hazer 400 SGM HZL 1 is a non toxic solution tha
5. SGM GB Sommario E cg E O gt em A O 2 HAZERILIQUID ta gra via a LC A E Gard aaa os tsk 10 TECHNICAL SPECIFICATION Sansen tenane eman perda ade RR ada nein pragas pda Dada mamas pda no pentane eta paid Ti EIMITED WARRANTY aaa 1 00 10 07 2008 SGM Starting Document Revision Date Author Description mm 99 aa Hazer 400 GB SGM 1 INTRODUCTION Thank you for choosing an SGM Hazer 400 Machine You now own a rugged and powerful state of the art machine Prior to use we suggest that you carefully read all of the instructions By following the suggestions found in this user manual you can look forward to the best virtually invisible Hazer effect and reliable satisfactory performance of your SGM Hazer for years to come Please follow these operation and safety instructions to ensure a long and safe life for your Hazer 2 IMPORTANT SAFEGUARDS DANGER OF ELECTRIC SHOCK Keep this device dry suitable for indoor outdoor use For all models use grounded electrical outlet Prior to use take care to determine that the unit is installed at the rated voltage Always unplug your SGM Hazer 400 before filling its tank Turn off or unplug when not in use This machine is not water proof If moisture water or Hazer fluid gets inside the housing immediately unplug the unit and contact a service technician or your SGM dealer before using it again DANGER OF BURN No user serviceable and modifying parts inside
6. evident damage caused by transportation In the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your SGM dealer for assistance 2 Hazer 400 SGM GB 4 SETUP Remove all packing materials from the shipping box Check that all foam and plastic padding is removed Place Hazer on a flat surface and remove Hazer liquid tank cap Your Hazer 400 may come with standard Timer remote HC 1 If you will be controlling your unit remotely firmly attach the remote control cable to the proper position OPERATION Place the unit on a flat surface Plug power cord into a grounded electrical outlet Set the power switch to ON on the back of the machine Make sure that the red indicator light is on Remove the black liquid tank cap pour Hazer liquid into the liquid tank about 1 2 full be careful not to exceed the maximum fluid level DO NOT OVERFILL Use only dealer recommended high quality Hazer liquid Any other types of fluid may cause health hazard and damage the unit Use of any other liquid may void warranty Connect the remote controller to the unit press the red button ON OFF to start up the unit For further information on operating including DMX your SGM HZ 400 Hazer see the section titled Remote Control Operation There s an adjustable nozzle blade where you can adjust the angle of the Hazer output by adjusting the thumb screws indicated below
7. lug the unit immediately from the mains Check the fluid level the external fuse the remote control connection and the power cable from the wall If all ofthe above appears to be O K plug the unit in again If the Hazer still does not function discontinue operation or it may result in permanent damage to the unit Return the machine to your SGM dealer Always drain tank before mailing or transporting this unit 7 REMOTE CONTROL OPERATION HC 1 10 meter wired multi function remote controller with 1 4 stereo plug Red CONTROL ON OFF Green HAZER Yellow TIMER ON OFF DURATION and INTERVAL knobs Connect the unit to the mains set the power switch on the at rear of the machine to on Press the red button CONTROL ON OFF the red indicator light will be on at the same time This Hazer machine is ready to operate Keep the green button HAZER pressed the unit will produce continuous Hazer output Release the button to stop output During this time the red button CONTROL ON OFF is kept pressed while the red indicator light is still on Hazer 400 SGM GB Press the yellow button TIMER ON OFF to activate the timer function for the knobs DURATION and INTERVAL located on the top of the controller Adjust the interval between each Hazer emission within the range from 10 to 200 seconds by means of the INTERVAL control knob Adjust the duration of each Hazer emission within the range of 5 to 100 seconds by means of the DURATIO
8. t produces a pure translucent Hazer with extremely long hang time and low moisture perfect for HZ 400 Important Never mix oil based and water based Hazer liquids Before switching the kind of Hazer liquid in use completely drain the Hazer s tank to avoid mixing 10 TECHNICAL SPECIFICATIONS Model HZ 400 Power supply AC100V AC120V AC230V AC240V 50Hz 60Hz Power consumption 560 W Output volume 84 m3 min Tank capacity 2 5 liters Fluid consumption 16 Std liter Weight 18 5 kg Dimensions LxWxH mm 500 x 320 x 246 Remote included HC 1 Optional remote HCR 1 Save these instructions 11 LIMITED WARRANTY The unit is guaranteed for 24 months from the date of purchase against manufacturing material defects Breakdown caused by carelessness and improper use of the fixture is excluded The guarantee is no longer valid if the unit has been tampered with or repaired by unauthorized personnel Replacement of the fixture is not foreseen by the guarantee External parts knobs switches removable parts and lamps are excluded from the guarantee Transport costs and related risks are borne by the fixture s owner The guarantee is valid to all effects only on presentation of the guarantee certificate to the manufacturer or the nearest SGM technical assistance centre Always quote the unit s serial number and model when contacting your reseller for information or assistance NOTE USE OF ANY FLUID

Download Pdf Manuals

image

Related Search

Related Contents

  Planificación Semanal Proyecto: Asistente Samuel Robinson  Philips CD Soundmachine AZ1852  Philips Aluminium Collection Pusher CP9164  manual do usuário  マニュアル(3.2MB)  LIVELLO LASER ROTANTE  This EEE is compliant with RoHS  

Copyright © All rights reserved.
Failed to retrieve file