Easergy W200 - W500 - Schneider Electric België

image

Contents

1. measurement Sensor PT100 sensor 2 wires Accuracy 5 measurement between 25 and 150 C Active power Accuracy 3 integrated over 10 min RMS power Power factor True RMS up to harmonic 17 Accuracy 3 integrated over 10 min Accuracy 3 from 0 8 capacitive to 0 5 inductive Powered inputs 5 VDC Dry contact outputs 3 Relay outputs 2 A at 230 VAC Dielectric IEC 61010 Insulation 50 Hz 1 min 2 kV EN 60 950 Impulse voltage 1 2 50 us 5 kV Electromagnetic Electrostatic discharge IEC 1000 4 2 Level 3 Radiated field IEC 1000 4 3 Level 3 Fast transients IEC 1000 4 4 Level 4 Impulse waves IEC 1000 4 5 Level 3 Radio frequency IEC 1000 4 6 Level 3 Magnetic field 50 Hz IEC 1000 4 8 Level 4 Voltage breaks IEC 1000 4 11 Damped oscillating waves IEC 1000 4 12 2 5 kV common mode 1 kV differential mode Impulse wave IEC 1000 4 5 Between lines 1 kV between lines and earth 2 kV Emissions EN 55011 Class A Climatic Temperature 25 C to 55 C Relative humidity IEC 68 2 3 Less than 95 at 40 C without condensation Salt mist IEC 68 2 11 168 h Storage temperature IEC 68 2 14 40 C to 70 C Mechanical Vibrations IEC 68 2 6 10 to 500 Hz 1 g or 0 075 mn peak to peak Protection IEC 60529 IP21 Supply voltage Battery 230 VA 15 50 Hz 60 Hz 2 h battery life Integrated GSM modem Measurement extension Easergy W500 Server installed on PC Communication to Intranet Dual band 900 1800 MH
2. reference Base Metering Sensors Application 6 DI 3 DO GSM 1LV channel 31 U 0 W200 62402 W200SG2ZZZ Digital data 62407 vasca few 3CT 1 MV LV transformer 62404 W200SG2N1Z Not supplied W500 62400 W500 ee WEB server e Schneider Electric PE40000 Easergy W200 Description of functions Operating and maintenance aid Voltage measurement Voltage measurement is taken on one phase W200 power supply This measurement enables monitoring of the quality of service and generating of an alarm if the voltage is too low adjustable low threshold Apparent power measurement The RMS current and RMS power are measured on the LV busbars The aim is to give information on the change in the transformer s apparent power Transformer temperature measurement The temperature is taken using a PT100 sensor in the transformer Inputs outputs The 6 digital inputs enable specific requirements to be met relative to MV LV substation operation such as m detection of LV fuse blowing m adding of MV fault indicators m opening of the MV LV substation door m substation in local remote mode m position of MV switches Similarly the 3 output relays can be used to remotely control a device in the substation The operator has the possibility of programming an alarm in the case of a change in status Recording suited to substation monitoring Recording suited to substation monitoring E Integrated power every 10 minutes m H
3. PE40000 Technical data sheet 2008 MV network management Easergy W200 W500 Network remote monitoring Presentation The W200 is a product dedicated to remote monitoring of MV LV substations It provides the following functions m recording power and temperature measurements m recording data from 6 digital inputs m sending orders via 3 outputs m detecting breaks in voltage m communicating via GSM Data is accessed m via Intranet Internet through the Easergy W500 server which can generate email alarm messages m by SMS messages on a cell phone The W200 exists several versions Basic version 6 digital inputs DI 3 relay outputs DO and GSM link Version with 1 measurement channel with CT Basic version with 3 analog inputs 1 for current measurement 3 phases plus an analog input 8 for transformer temperature measurement and one voltage measurement analog input U This version includes 3 opening current sensors CT adapted to measuring currents with a rating of 1300 1 Version with 1 measurement channel without CT This version is equivalent to the previous one It can be adapted to all types of sensors CT supplying a secondary current 0 5A The W500 is an INTRANET access server m Integrated in the company INTRANET network o password protection O possibility of INTERNET access m RTC communication with substations m HTTP server compatible with standard browsers Cat no Sales
4. ourly average over the past week and for the week with the year s peak value m Maximum per day and per month over 1 year m Maximum per year Logging of 200 date stamped events m Voltage breaks mg MV LV transformer temperature thresholds m Power thresholds m Miscellaneous substation data equipment actions m Recording changes in status of inputs outputs Communication m Integrated GSM interface or RS232 link m Automatic event related call alarms m Cyclic call Configuration m Local with laptop PC m Remote via the INTRANET network Schneider ES Flectric Easergy W500 Description of functions Easergy W500 server software Characteristics m PC software running under Windows 98 NT or 2000 n m requires a Modem on the COM1 serial port s r m manages the database of data from W200 units up to 8 000 substations m custom text for each substation 600 characters m integrated in the corporate Intranet network or in Internet E http server compatible with standard browsers PE55130 Saibelatlon satus WIM demo Record of IEUD 1i iidT Functionalities m file download m reports view and print of event files and measurements or import in another database m remote parameter configuration Internet Intranet version For more details refer to the W500 user s manual Alarms The alarms are triggered by the crossing of a threshold temperature power or voltage or even by modifying the statu
5. s of one of the digital inputs A GSM call to the Easergy W500 server is initialized which will give e mail alarms to the operators concerned and or send an SMS according to the selected settings DE55441 Event log The W200 record the last 150 events in an event log Each new connection enables the Easergy W500 server log to be updated Local configuration mode This enables the W200 to be configured locally using a PC running under Windows 98 NT 2000 or XP and a specific lead Menu based W200 configuration and operation m communication parameter definition telephone n SMS m setting alarm thresholds for powers voltages and temperatures m viewing RMS and active currents voltages and powers temperatures and digital data m recovering W200 recorded values in file form m development tools m setting up automatic daily calls Simplified installation Easergy W500 is distributed on CD Rom The computer on which Easergy W500 is installed requires m 1 RTC modem type V90 m 1 Ethernet link m 1 browser Internet Explorer Netscape Schneider ES Electric Easergy W200 W500 Easergy W200 Characteristics Current measurement with CT Easergy sensors busbars 70 x6 mm Accuracy 3 measurement between 0 and 1500 A Current measurement withoutCT 3 Current accuracy 1 Voltage measurement Supply voltage measurement just one phase Accuracy of 1 between 180 and 270 V Temperature
6. z Antenna supplied with 4 m cable 3 current measurement inputs and a PT100 Windows 98 NT 2000 XP Ethernet TCP IP port Communication to W200 Standard RTC modem COM1 not supplied Capacity 8 000 substations Schneider Electric Industries SAS 89 boulevard Franklin Roosevelt F 92506 Rueil Malmaison Cedex Tel 33 0 1 41 29 85 00 www schneider electric com www easergy com ENMED307023EN As standards specifications and designs change from time to time please ask for confirmation of the information given in this publication oe This document has been printed on ecological paper Publishing Schneider Electric Industries SAS Design Schneider Electric Industries SAS Printing Imprimerie du Pont de Claix JPF Made in France 10 2007 ART 832553 Schneider Electric Industries SAS All rights reserved