Home
WIRELESS PIR SENSOR
Contents
1. wireless PIR has a 2 minute warm up period after it is powered up 2 Programming the detector into your Wireless control unit system Press keys on Wireless control unit as follows The User PIN code is factory set to 1234 or different if you have setup your own unique PIN code 1 Input user Pin lt 1 gt lt 2 gt lt 3 gt lt 4 gt and lt Reset gt button while the CU is in standby mode 2 Press and hold the lt Learn gt button for over 5 seconds to enter Learn Mode with two beep sounds from CU 3 Hold the Detector at least 0 5m away from the CU Within 10 seconds trigger the Detector by moving your hand it front of the PIR lens The CU will beep twice and the Learn LED will turn ON If no beeps are produced then the CU has reach its full capacity of PIR Detectors 4 max 4 Any Z1 to Z4 LEDs flashing indicates corresponding PIRs have been added Z1 to Z4 LEDs OFF indicates corresponding PIRs are not yet programmed into these zones The maximum capacity of the system is 4 wireless PIRs 5 If any further Detectors need to be added then trigger the next device within the 10 second learning period If this period has expired then re enter learn mode 6 Programming order of the CU Zone5 gt Zone6 gt Zone7 gt Zone8 7 Ifno more devices are added all zone LEDs will turn off after 10 seconds and the CU will return to standby mode Final Setup IMPORTANT To extend the battery life wireless PIR detectors are
2. WIRELESS PIR SENSOR USER MANUAL Wireless PIR Features EXTRA Low current draw S M D Technology 12m 110 Convex honey comb hemispherical infra red lens Excellent false alarm suppression Walk test LED High RFI amp EMI Immunity Introduction The Wireless PIR is a dual element passive infra red intrusion detector for use in wireless electronic security systems The Wireless PIR is easy to install by learning without connecting any cables from the Security Control Unit The Wireless PIR is compact attractive and easy to install it can be mounted indoors on a wall or in a corner The Wireless PIR is ideal for commercial office and residential applications The Wireless PIR detects intrusion by determining changes in infra red energy patterns The Wireless PIR emits no radiation and is harmless to humans amp animals The Wireless PIR reduces false alarms to a very low level due to its effective elimination of background noises and nuisance stimuli Please follow the following steps in order to correctly install 1 Installing batteries in the detector Note Do not use rechargeable zinc carbon or zinc chloride batteries in the detectors 1 Insert two AAA size alkaline batteries as shown taking care to observe correct polarity Illustration 1 Illustration 1 Note The
3. ace the electronic module into the retaining clips ensuring that it is correctly positioned and firmly seated Install the battery into the battery snap Replace PIR cover and refit retaining screw Illustration 3 Illustration 4 5 Power the CU again Power up the CU again The system will return to standby ready for use Lens Arrays bide View Top View Specifications Type Dual Element low noise Pyroelectric sensor Housing ABS Transmission range 150 metres open air with direct line of sight Transmission frequency 433MHz Test LED Selectable on off Mounting Height 2 2 5 m Distance Range Up to 12 meters Power Supply 3VDC 2 x 1 5V AAA Alkaline battery Batteries are excluded Battery Life Approx 18months
4. designed to detect once only before entering a Sleep condition for two minutes during which the unit will not trigger Any movement seen by the PIR during this period causes Sleep condition to be extended by a further two minutes Therefore a wireless PIR which is constantly sensing movement such as a person walking around a room may appear to be non functional you will find that the PIR will detect normally again following a two minute period with no movement present The wireless PIR detector contains one jumper which activates deactivates the LED If required that the LED will be off when the detector is triggered during arm pull this jumper off otherwise leave the jumper on If you choose to leave the LED on bear in mind that this will reduce battery life Illustration 2 This LED is normally used only walk testing to ensure the PIR covers the detection area satisfactorily and then turned off LED LED OFF Illustration 2 3 Power OFF the CU Power OFF the CU completely after the Detector s have been learnt by isolating the backup power battery and mains power adaptor to prevent the tamper function of the Detector s from triggering the alarm of the CU when mounting 4 Mounting Location The PIR is designed for indoor use It should not be mounted near to large metalobjects or on metal surfaces It needs to be mounted on a wall or in a corner at a height of approxi
5. mately 2 2 5meters for the best general coverage in an average room The detector has been designed to avoid false alarms nevertheless it is best to avoid facing sources of heat such as fires and boilers and always try to keep away from a window A PIR can look at a radiator but should not be sited above one Do not site a PIR where its field of view may be obstructed e g by curtains Also note that PIRs work best when sensing movement across rather than along their detection beams 2m to 2 5n S X Fire Boiler Radiator v x Mounting the detector 1 Remove and retain the screw from the bottom of the PIR and lift off the cover Illustration 3 2 If you are fitting the PIR in a corner use mounting points A if you are fitting the detector on to a flat surface use mounting points B the mounting points are shown by indentations in the plastic molding Use a small drill to create two fixing holes at the mounting points Illustration 4 3 Hold the base of the PIR in the chosen position ensuring that the front of PIR will face towards the centre of the protected area and mark and drill two 5mm fixing holes in the wall DO NOT drill holes with the PIR in position the resulting dust may damage the unit Secure the PIR to the wall using two screws 25mm countersink and the wall plugs 4 Repl
Download Pdf Manuals
Related Search
Related Contents
Fujitsu Casual Sleeve 16 見 積 仕 様 書 CDE-120R DE Page1 copy L.M.D. MASTER ACADEMIQUE - Université des Sciences et de la Maroo MR-MS3001 KOHLER K-3554-RA-0 Installation Guide Magellan Roadmate 2230T LM DVR User Manual Samsung NX05BP1VM2 Manuel de l'utilisateur Scosche KA2410SB car kit Copyright © All rights reserved.