Home
USER MANUAL
Contents
1. 6 10 POWER SUPPLY RESET CODE 9 The function is used for handling special detectors equipped with individual on off memory which is cleared by shutting down power supply for example smoke detectors Calling the function temporarily disconnects power supply for such detectors The function is active when the RESETTABLE POWER type is selected for one of the outputs 6 11 EVENTS FUNCTION 10 ONLY LCD KEYPAD The function is available in LCD keypad and makes it possible to view the whole contents of the events log the last 255 To view the events the user function menu should be opened with master user code or with service code and next the Events function should be called The way of viewing is described in section HOLD DOWN USER FUNCTIONS 6 12 TESTING OUTPUTS AND LED INDICATORS CODE 11 The function makes it possible to check the current status of the control panel outputs active inactive as well as functioning of the outputs and devices connected to them After calling the function from the LED type keypad the control panel will indicate the current status of outputs on LEDs with corresponding numbers 1 OUT1 2 OUT2 3 OUTS The lit up LED means active output the extinguished LED inactive output In the LCD keypad the status of outputs is displayed on the first three characters of the second line of the display The active outputs are indicated by displaying a corresponding digit 1 2 or 3
2. c G c O a amp USER MANUAL CE N WARNING In order to avoid any operational problems with the control panel it is recommended that you read carefully this manual before you start using the equipment Making any construction changes or unauthorized repairs is forbidden This applies in particular to modification of assemblies and components Maintenance or repair operations should be performed by authorized personnel i e the installer or factory service The control panel can only work with analog subscriber lines Connecting the telephone circuit directly to a digital network e g ISDN will result in damage to the equipment If the analog telephone network is to be replaced by the digital one please consult the installer of your security system Pay special attention if the telephone line used by the control panel is frequently busy and or failures are reported concerning the line and or monitoring Report such situations to the alarm system installer immediately CAUTION The alarm system is fitted with a battery which contains lead After expiry of its service the battery must not be thrown away but disposed of as required by the existing regulations European Union Directives 91 157 EEC and 93 86 EEC Latest EC declaration of conformity and product approval certificates can be downloaded from web site www satel pl DEFINITIONS OF SOME TECHNICAL TERMS AS USED IN
3. and the inactive by displaying a dot In order to carry out the functional test of the output arm disarm press the key with the number of specified output By repeatedly pressing the same key the output status will be toggled to the opposite one Activation deactivation of an output is acknowledged by three short beeps Additionally the function makes it possible to check operation of the LEDs in all keypads connected to the control panel Press the key 0 when the function is active to light up all the LEDs indicators and keypad illumination which were unlit at the given moment Press any key with another digit number to extinguish the LEDs which were turned on for the duration of the test After quitting the function key or the control panel will restore the previous status of the outputs from before calling the function 6 13 SERVICE ACCESS CODE 12 The function which is available to the master user allows the installer to access the system by using the service code It requires some data i e the time period during which the service mode of the control panel will be available to the installer service After expiry of the preprogrammed time the access will be blocked except when the value 99 is set which makes permanent the service mode access by using the code default setting In order to CA 5 SATEL 19 program the access time call the function enter two digits to indicate the time using Zero
4. 4009 gt l uoz ssedAg lesn 9SEJ 5 MON po obueUD INMA HES suoijoun wasn 4GOD WHV TV 201 S9 EAIOE 09S 40 Sulss ld uv TV OINVd SSIEAINOE 99S 10 Buissaud 0 sf LO IN OD o Huimaa Alowau lqno SS9 EAI 9E 09S 10 Bulssaid 9 Aejdsip lqno n ue11n9 sayeayoe Q S 10 Buissaud 7 09S 104 Z Asy ss d Buimela Alowaw HOOU9 0 5 5 Ul a qnox eoluyo9 JO 09S 10 Bulssaud c s yeorpul lqno n ssoi6oJd ul Aey p ew yx Buruq pawe uonnued UO powie possedAq uoz LEI Jadwe uoZ 1012 Alowow 5 wieje uOZ e Asowaw wieje Sulyullq pejelola s dule uoz 1032 MH wee lis UO POJEIOIA uOZ wee MO uoz S UOZ PALE JO SNIS Anou pue AV TdSIQ 4971
5. keypad keys EXAMPLE 0 arming The control panel cannot arm the system when e analarm condition is signaled by the panel the rib ALARM LED is blinking 8 USER MANUAL CA 5 e the panel is not ready to arm the system which is signaled by the panel with three long beeps see description in the previous paragraph of this manual e the function is disabled by the installer this situation will be signaled with two long beeps 4 9 DISARMING AND ALARM CLEARING CODEJ If the panel is armed the ARMED LED is on or blinking and or it signals an alarm the LA ALARM LED is on or blinking entering the user access code and confirming it with the or key will disarm the system and clear the alarm f while entering the access code you make a mistake press the key and re enter the code The control panel will confirm acceptance of the command by four short beeps and a long one and by extinguishing the gt ARMED LED and or ALARM LED if it was on The service code can only clear the tamper alarm or the keyboard alarm when the ARMED LED is off the control panel is disarmed The panel will not disarm the system or clear the alarm when the access code is wrong The user access code No 5 will not clear the alarm in the armed mode if a special operating mode has been selected for it by the installer and the system was armed by another user Refusal to clear the alarm is signaled with
6. DELAYED zone the system becomes disarmed without triggering any alarm the memory of the first alarm violation will be automatically reset CA 5 SATEL 5 Some of the LED indicators are only installed in the LED type keypads their functions in the LCD keypads being taken over by the display 4 2 STATUS OF CONTROL PANEL ARMED ZONES IN LCD KEYPAD The first five characters counting from the left in the LCD display lower line indicate the state of detectors attached to the control panel armed zones Stated below are the symbols which may be displayed there as well as their respective meanings the zone is free not violated the zone is violated M 2EOL zone tamper violated a the zone caused an alarm condition alarm memory A the zone has been violated or caused alarm as the first one counting from the moment of ending the exit delay countdown after arming see notes in the section on LED FUNCTIONS s zone triggered the tamper alarm memory of 2EOL zone tamper alarm S tamper alarm caused as the first one for 2EOL zone b the zone is bypassed 4 3 CONDITIONS SIGNALED ACOUSTICALLY IN THE KEYPAD The beeps generated to confirm the operation on the keypad e one short confirmation of pressing a key activation of the review function in the keypad HOLD DOWN 5 6 7 three short confirmation of entering the mode of user functions programming deactivation of the chime signaling in the keypa
7. In order to delete selected access codes it is necessary to extinguish their corresponding LEDs digits and accept the selection with the key The LEDs digits indicate which access codes will remain in the system after quitting the function CA 5 SATEL 15 EXAMPLE deleting the third and fifth user s access codes Master user code 7890 7 8 9 0 calling the user function mode confirmed with three short beeps and in the LED keypad additionally slow blinking of the l PROGRAM LED 3 calling the erase user function confirmed with two short beeps and in the LED keypad additionally with lighting up of LEDs with the numbers of existing codes e g 1 2 3 4 5 and with fast blinking of the PROGRAM LED in the LCD keypad this function may be called using arrow keys Satel 3 5 indicating the numbers of deleted access a codes confirmed in the LED keypad by Whom to leave extinguishing of the LEDs with numbers 3 oe A and 5 the LEDs 1 2 and 4 are still lit up and in the LCD keypad by disappearing of BR 52 b digits 3 and 5 from the display digits 1 2 and 4 are still on deleting the selected access codes four short beeps and a long one signal end of the function 6 5 BYPASS ZONES CODE 4 The function enables bypassing of the zones in order to arm a part of the system or to bypass malfunctioning detectors in the armed mode After calling the func
8. THIS MANUAL e Service mode the control panel condition which permits calling of the service functions and programming of the security system parameters e User function mode the control panel condition which permits performing the user code protected functions which are described herein CONTENTS 1 TECHNICAL RELIABILITY OF THE SECURITY 8 9 2 2 2 ALARM SYSTEM GEERT 2 3 GENERAL FEATURES Aaa o yaba Wo oe Wd 2 4 OPERATION cala ati iwa diana ete 3 ri CED FUNCTIONS ea Rad nt ODA AE A ROZA x 4 4 2 STATUS OF CONTROL PANEL ARMED ZONES IN LCD 5 4 3 CONDITIONS SIGNALED ACOUSTICALLY IN THE KENYPRAD iii 5 4 4 EVENTS SIGNALED ON THE OUT OUTPUT 2er deed 6 45 USER ACCESS CODES ee kwa dak Ga 6 4 6 ARMED MODE OF THE CONTROL PANEL ar EO ENGEN SNE ENEE Ne 6 4 6 1 iad o lee etal A 6 4 6 2 SILENT ARMED MODE dae a eee 7 4 6 3 PARTIAL ARMED MODE WITH NO EXIT FROM THE SITE 7 4 7 lt ARMINGICODEJF eee GEE W o b RK LEE 7 4 5 QUK ARMING O H eni ana a Aa r EE ee 7 4 9 DISARMING AND ALARM CLEARING CODE A 8 4 10 REMOTE ARMING DISARMING AND CLEARING ALARM iii 8 5 AIOLD DOW ING USER FUNCTIONS SEE e EL 8 LOOKEYPA EE 8 5 1 ALARM MEMORY REVIEW 5 caen AE etek GDA dace OO EEEE kt renee 9 5 2 TROUBLE MEMORVRAEVIEW Gl
9. changing the master code or the service code none of the LEDs 1 5 is on EXAMPLE changing the access code from 1234 to 7890 1 2 3 4 calling the user function mode confirmed CU Satel with three short beeps and in the LED keypad additionally with slow blinking of the gt 1 Change code 3 PROGRAM LED 2 New user 1 calling the change code function confirmed with two short beeps and in the LED keypad additionally with fast blinking of the PROGRAM LED in the LCD keypad this function may be called using gt or keys 7 8 9 O entering the digits of a new code and accepting it confirmed with four short beeps and a long one return of the control panel to the normal operating mode 6 3 ADDUSER CODER This function permits adding new users of the system i e the access codes capable of controlling the panel operation It is only available to the Master code user As new users are added to the system they are automatically assigned consecutive numbers by the panel If the function is called after the number of entered users has reached five the control panel will generate three long beeps and will quit the user function mode If any of the codes have been deleted by means of the function 3 the control panel will allow new user access codes to be entered in their place After calling the function the control panel waits for entering the new user access code 4 to 8 digits
10. conditions up to the earliest item recorded e zone alarms one of the LEDs 1 to 5 is always lit up burglary panic fire tamper and other alarms depending on how the zone functions have been set up by the installer e keypad alarms one of the LEDs is off and the other LEDs 1 to 5 are on the meaning of the extinguished diode being as follows LED No ALARM DESCRIPTION Fire alarm keypad Panic alarm keypad Auxiliary alarm keypad 3 wrong access codes alarm Keypad tamper alarm short circuiting of bus wires cutting off of keypad 5 2 TROUBLE MEMORY REVIEW 6 This function allows the panel user to review the detailed information on the system trouble conditions from the panel memory log On pressing and holding down the 6 key until you hear a single beep the l PROGRAM LED will start blinking and the LEDs from 1 to 5 will indicate the type of trouble according to the list contained in the description of the CURRENT TROUBLE CHECK OUT function The list of detectable troubles consists of two sets of five items each Troubles relating to the first 10 USER MANUAL CA 5 set are indicated by the number of a lit up LED whereas troubles relating to the second set are indicated by the number of an extinguished LED one of five The previous earlier troubles are available for readout by consecutively pressing any key of the keypad except for the key which cancels the trouble memory re
11. in the beginning for numbers smaller than 10 and press the key Two zeros entered with this function for the number of hours automatically block the access The access time countdown is running whether the service mode is active or not The countdown can only be interrupted by disconnection of power supply 230V mains and or battery By calling this function you can check how much time remains until the access is blocked by the service code 20 USER MANUAL CA 5 7 HISTORY OF MANUAL UPDATES The changes described refer to the manual drawn up for the CA 5 v1 09 control panel DATE VERSION DESCRIPTION OF CHANGES New designations pictograms have been introduced for the keypad LEDs The way of indicating the entry delay countdown in the keypad has been changed p 5 April 2 10 nformation on the options to restrict the arming disarming signaling on OUT1 output by 2007 the installer has been added p 66 Information on acoustic signaling in the keypad of arming disarming by means of remote control button etc has been added p 8 SATEL sp z 0 0 ul Schuberta 79 80 172 Gdansk POLAND Tel 48 58 320 94 00 info satel pl www satel pl SS909B Z is indino LL ulfeubis swIyo S U AZ 0 INYV TV XNV S9 EAI OEOP SO BAI OE Jose Ajddns 18mM04 sayenioe 90S 40 Bulssaid 0 Q S 40 Bulsseud g s nd no iq wieje Gueo 9 SE Bulwuesip Gule 4
12. keypad allow the user to scroll through the list of events provided by the alarm control panel The events are displayed chronologically 4 earlier ones later ones The lt gt arrow keys on the left side of the keypad make it possible to display the user or zone name default one or entered into the control panel memory by the installer using the DLOAD10 computer program Pressing the same key again will restore the previous mode of event information display CA 5 SATEL 9 rib atei Rz amper alarm Lp CAS Fig 3 Example of events description The event description contains date day and month time of event hour and minutes source code if possible kpd keypad zo N n 1 2 5 zone number US n 1 2 5 ordinary user number n 6 master user n 7 service name of event description in words Pressing the key terminates the viewing function The method of reading information from the LED keypad is described together with particular functions 5 1 ALARM MEMORY REVIEW 5 Holding down the 5 key until a single beep is heard will display information on the most recent alarm condition The PROGRAM LED will be blinking and the LEDs 1 5 will indicate the cause of the alarm Pressing any key except for the key which gives you the option to quit the memory log review immediately displays the previous alarm
13. output If this output controls the siren operation it will generate short sounds in much the same way as in the car alarm systems The signals have the following meanings e one short sound arming e two short sounds disarming e four short sounds clearing the alarm or disarming and clearing the alarm Additionally the OUT1 output signals the typical situations for the security system continuous signal burglary alarm intermittent signal 1s 1s fire alarm The installer may select the identical manner of signaling for the fire alarm and for the burglary alarm i e the continuous signal he can also with the use of a corresponding service function disable the OUT1 output signaling of arming disarming from the keypad 4 5 USER ACCESS CODES For everyday operation of the system it is necessary to know the user access code the access code is a sequence of 4 to 8 digits within the range of 0 9 To enter the access code in the control panel press the corresponding keys on the keypad in the order of the code digits and finish the full sequence by pressing the or keys as may be required The control panel comes with the following factory settings master user access code 1234 service code 12345 By using the master user code you can program 5 additional user access codes or to delete them if they were programmed before The installer can assign specific authority levels to some of the access c
14. repeat the function calling attempt two long beeps mean lack of the programmed computer number or unavailability of the function to the given user Notes e The function enables connection between the panel and the computer when the option to establish communication from outside from the computer is blocked e Initiation of the programming from the outside may be useful e g when the user is often absent from the site and there is an urgent need for service intervention or remote testing of the security system Programming the computer telephone number when the function initiating the programming from the outside is available is an extra safeguard against the panel being accessed by any computer except the service one in case unauthorized persons know the communication access codes e t is possible to block the service computer access to the control panel for the time of armed mode 6 2 CHANGE ACCESS CODE CODE 1 The function permits changing the access code of the user who has activated the function It is only unavailable to the user 4 if a special duress action authority level has been selected for him Such an access code can only be changed by the master user by deleting and re entering it Having called the function enter the new access code and press the key 14 USER MANUAL CA 5 In the LED keypad the number of the lit up LED 1 5 indicates which access code is being changed When
15. three long beeps 4 10 REMOTE ARMING DISARMING AND CLEARING ALARM The installer may install in the security system a radio controller to make remote control possible or a special button designed for quick arming disarming of the system or clearing of alarm For this purpose one of the control panel programmable zones is used The system will be always armed in this mode by violation of the zone irrespective of the status violation of the other zones of the control panel Arming disarming is signaled in the keypad by 4 short beeps and 1 long beep The installer may restrict the zone operation to arming only while disarming and alarm clearing will require the user access code To facilitate remote control of the panel the installer may activate the signaling of arming disarming on the OUT1 alarm output see Events Signaled on the OUT1 Output 5 HOLD DOWN USER FUNCTIONS The functions are available to every user of the protected site without using the access code They are activated by holding down the function key until audible signal sounds in the keypad The first three functions refer to viewing the alarms and troubles Depending on the keypad type the viewing is done in different ways LCD keypad To start the viewing call the function and press any of the arrow keys information on the most recent alarm condition referring to selected function will be displayed The 4 v arrow keys on the right side of the
16. Afterwards the key should be pressed In the LED keypad the number of the user code being programmed is indicated by blinking of one of the LEDs 1 to 5 In the LCD keypad the number of the user code is displayed EXAMPLE entering the new user access code 4938 master user access code 7890 7 8 9 0 calling the user function mode confirmed with three short beeps and in the LED keypad additionally with slow blinking of the PROGRAM LED 2 calling the enter new user access code function confirmed with two short beeps and in the LED keypad additionally with lighting up of one of LEDs 1 5 and fast blinking of the PROGRAM LED in the LCD keypad this function may be called with arrow keys 1411919 181121171 1 entering the new code digits and accepting it confirmed with four short beeps and a long one return of the control panel to the normal operating mode 6 4 ERASE USER CODE 3 The purpose of this function is to delete the access codes of existing users if the contents of their code is lost or to revoke the current users authority to operate the security system The function is only available to the Master user After calling the function the control panel will light up the LEDs with the numbers of current user codes and will display their numbers in the LCD keypad Pressing the key with the digit corresponding to the number of existing access code will extinguish the given LED digit
17. amming of the security system parameters and downloading the event memory log The function can be called by the master user and the service The computer program makes available to the computer operator a keypad working simultaneously with the real keypads installed in the system and provides detailed monitoring of the system including the status of its zones and outputs The knowledge of the users access codes makes it possible to use the computer pad in the same way as any additional system keypad most of the user functions are available On activating the function the panel engages the telephone line and connects to the service computer During the data exchange the telephone line will be busy The service can temporarily free the telephone line by suspending the downloading and then calling the control panel again to continue the data exchange The installer should make the users aware of it so that they will not answer the incoming calls to allow re establishing of the connection and correct completion of the transmission Connection between the control panel and the computer after the panel is appropriately programmed can be initialized from outside by the computer calling the control panel and also can be effected by the installer in local mode using the corresponding service function The meaning of audible signals generated on activating the function three long beeps mean that the line is engaged by monitoring wait and then
18. anize evacuation 2 ALARM SYSTEM OPERATING COSTS The main task of the control panel is signaling and efficient reporting of alarm situations and as far as the monitoring function is concerned keeping the monitoring station informed about the protected facility status Performance of these functions is to a large extent based on the use of a telephone line which entails generating certain costs Generally the level of costs incurred by the alarm system owner depends on the amount of information the control panel has to transfer to the monitoring station A failure of the telephone links as well as incorrect programming of the control panel may considerably increase these costs Such a situation is usually related to an excessive number of connections made The installer can adjust functioning of the alarm system to the specific conditions and the type of protected site however it is the user who should decide if his or her priority is transferring information at any price or if some technical problems occur the control panel is allowed to skip some events the reception of which has not been confirmed by the monitoring station 3 GENERAL FEATURES The CA 5 alarm control panel is an advanced microprocessor based device designed for burglary and panic alarm systems It is characterized by simplicity of operation legibility of information for the user and a high operational reliability It has been fitted with a telephone communicator d
19. ation of selected zones when the control panel is disarmed from the keypad Three short beeps in the keypad confirm switching off the chime signaling function whereas four short beeps and a long one mean that the signaling is on The installer specifies which zones will generate the chime signal 5 5 FIRE ALARM This function makes it possible to trigger the fire alarm from the keypad The control panel activates signaling on the OUT1 output in the keypad and sends an appropriate code to the monitoring station The function can be disabled by the installer 5 6 AUXILIARY ALARM 0 The meaning of this alarm is specified depending on the needs The function may transmit information on the auxiliary alarm to the monitoring station it may be for example a call for medical assistance as it was adopted in the Contact ID monitoring format The function may be disabled by the installer 5 7 PANIC ALARM This function makes it possible to trigger the panic alarm from the keypad The control panel activates signaling on the OUT1 output in the keypad and sends an appropriate code to the monitoring station The function can be disabled by the installer or limited to the keypad and monitoring only the SILENT panic alarm 6 USER FUNCTIONS ACCESSIBLE WITH ACCESS CODE If the control panel is not armed and is signaling no alarm the users can access several functions useful in everyday operation of the security system The user functi
20. cess code 39763 press in turn 3 9 7 6 3 The control panel may fail to arm the system if e the panel is not ready for arming the system there are zones defined by the installer which must not be violated or tampered while the system is being armed PRIORITY option and one of them is being violated or tampered the panel signals this state with three long beeps and displays the names of violated zones on LCD keypad In such a situation you should wait until all the zones are ready in the LED keypad the LEDs 1 5 will go out in the LCD keypad symbols of zone violation and then arm the system again enter the access code If for example one of the zones remains all the time violated in the LED keypad one of the LEDs 1 5 is always on in the LCD keypad the symbol of zone violation is displayed it may be caused e g by the detector failure the armed mode can be activated after bypassing the given zone using the function 4 e the access code is incorrect this situation is signaled with two long beeps e at least one output in the system performs the DURESS ALARM function and is on active Using the code which does not carry out the action under duress function will reset the a m output activity three short beeps without arming the system the system will only be armed on using any code again 4 8 QUICK ARMING 0 Quick arming without using any access code is possible by consecutive pressing of two
21. cking step pressing the key at this moment will generate the Clock programming event downloading of next digit 0 9 1 1 two long beeps the LED indications remain unchanged quitting the function without changing the date signaled by two long beeps The following data have been downloaded from the control panel time 15 39 date September 11 5 8 MONO ourpuTs 00084 2O02 ICODEL The purpose of the function is determined by the installer It can for instance activate electromagnetic locks bells signaling lamps or any other devices The function is available when the MONO SwITCH type has been selected for one of the outputs Using this function svvitches on the output for a time specified by the installer Performance is confirmed by four short beeps and a long one 18 USER MANUAL CA 5 6 9 Bl OUTPUTS CODEJ 8 The purpose of the function is determined by the installer It can be used for example for switching on the external lighting or any electrical devices The function is active when the BI SWITCH type is selected for one of the outputs Using the function will permanently change the output status into the opposite one until the function is used again An inactive output will be activated and an active output will be deactivated Switching the output on is confirmed by the keypad with four short beeps and a long one while switching it off with three short beeps
22. d key 8 reset of the DURESS ALARM output activity one long lasting approx 1 5s an attempt to arm the system when the control panel is not ready there are violated or tampered zones with the PRIORITY option activated see Arming a refusal to enter the function two long a wrong access code canceling a function or incorrect data for a function three long the code is recognized but because of some reasons the calling function is not available or it can not be perform at the moment e g in case of the attempt to view a troubles memory when system is armed four short one long arming disarming entering the service mode successful completion of function programming activating the chime signaling in the keypad e six short partial arming there are some zones bypassed System events signaling continuous beep alarm e intermittent beep fire alarm e one short beep every 3 seconds service mode with the PROGRAMMING LED on e one long beep every 3 seconds indicates exit delay time countdown e two short beeps every 1 5 seconds indicates entry delay time countdown e five short beeps violation of the CHIME type zone Which events are to be signaled acoustically should be determined by the installer 6 USER MANUAL CA 5 4 4 EVENTS SIGNALED ON THE OUT1 OUTPUT The installer may activate the signaling of arming disarming and alarm clearing on the OUT1
23. date ensure correct interpretation of the events recorded in the panel memory log The history of events may be downloaded by means of the LCD keypad or the computer and its program managing the CA 5 alarm control panel The programming procedure is as follows HOURS MINUTES acknowledge H H M M MONTH DAY acknowledge M M D D The hour should be given in the 24 hour format with zero before the hour less than 10 It is possible to leave the function earlier after programming the time the date will remain unchanged by pressing the key twice Note In order to reset the Clock loss trouble signal the time and date must be programmed EXAMPLE programming time 7 45 and date 25 July user access code 1230 1 2 3 0 calling the user function mode confirmed EK UNE Satet with three short beeps and in the LED keypad additionally with slow blinking of the Time hh mm 3 PROGRAM LED 07 45 6 4 calling the set time function confirmed with two short beeps and in the LED keypad Ex additionally with fast blinking of the gt gt PROGRAM LED in the LCD keypad LA be called using arrow Dace m dj 0 7 4 5 entering the hours and minutes confirmed 07 25 with two short beeps e CAS 0 7 2 5 entering the month and day confirmed with four short beeps and a long one quitting the function The LCD keypad display p
24. de Set time programs panel clock MONO outputs MONO SWITCH output on BI outputs BI SWITCH output on off Power supply RESET on RESETTABLE POWER outputs type Events only in LCD keypad Outputs 8 LEDs test Service access Notes e The functions 2 3 and 12 are available to the master user only the regular user has only access to functions 1 4 5 6 7 8 9 The service code provides access to functions 1 4 6 7 8 9 10 11 e Access to some of the user functions functions 0 7 8 9 depends on the service settings For example if the system includes no MONO and BI outputs the functions 7 and 8 are not displayed in the menu e Pressing the key at any time makes the control panel quit the user function mode e Having performed the function or having refused to perform it the control panel always quits the user function mode To carry out a next function you must re enter the access CA 5 SATEL 13 code confirm it with the key select the function number and confirm it by pressing the key e Refusal to perform the function is signaled with three long beeps e g after calling the function 2 when all the access codes are already entered 6 1 START DOWNLOAD CODE 0 The function connects the control panel by telephone with the service computer the computer telephone number must be previously programmed by the installer for remote progr
25. e control panel is fitted with a backup power supply to enable a limited time operation without the mains supply if the AC loss is indicated despite the electrical installation being OK you should call the service Battery trouble means that the battery voltage is too low lower than 12V under load This condition may hold for several hours after AC supply loss or after connecting a discharged battery The battery charging time depends on its capacitance the battery is charged with direct current of approx 350mA the time necessary for testing the battery status is about 12 minutes Overload OUT1 output overload installation short circuiting usually requires intervention of the service personnel Overload power outputs information on the installation fault requires intervention of the service personnel it can be only displayed during the trouble memory review Clock loss occurs on disconnecting the power supply and restarting the control panel the clock and date should be set with the user function 6 No voltage on telephone line means cut off of the telephone line it may be also caused by lifting the handset of the telephone connected to the same line for longer than the time specified by the installer CA 5 SATEL 11 Problems with access to settings memory may occur when the RESET pins on the control panel main board are shorted If the pins are open and connecting the power off and on does not cl
26. ear the trouble signaling intervention of the service personnel is necessary Wrong communication codes means that during three consecutive communication sessions with the computer the control panel hanged up after reading a wrong communication code three times in such a case the panel suspends communication with the computer for 30 minutes upon answering a call it sends to the computer a message that the connection capability is disabled and hangs up Monitoring trouble ihis message indicates multiple occupancy of the line when the monitoring station fails to go off hook does not send the handshake or the acknowledgement signal after receiving the codes If this signaling persists the monitoring is ineffective and requires intervention of the service personnel or the technicians from monitoring station Dialing error information on the cause of an unsuccessful telephone connection lack of the dialing tone after the handset is lifted or presence of an intermittent signal instead of the continuous one The signaling of trouble will remain on until next successful telephone connection Depending on the programmed options the current trouble memory will be deleted on clearing the cause of trouble or only after running the above mentioned current trouble checkout function 5 4 SWITCHING THE CHIME ON OFF 8 This function holding down the 8 key makes it possible to switch on off the chime signal signaling the viol
27. en 9 5 9 CURRENT ele e EI KEE 10 5 3 1 DESCRIPTION OF SOME TROUBLE SIGNALING CAUSES nana nana aa aa za aa aa aa aa aa za za za aa As Ass s s s rnrn nenne 10 5 4 SWITCHING THE CHIME ON OFF 8 GOA ARAYIR RA HER EE dA KA 11 5 5 PIRE ALARM ant od ye ACE 11 5 0 KR EE RT EE 11 5 4 PANIC AIGA RIA kai ad ka fa kad ARE 11 6 USER FUNCTIONS ACCESSIBLE WITH ACCESS CODE 11 6 1 STARTDOWNEOAD COBEJH OH asusa te tete aaa 13 6 2 GHANGE ACCESSCODETCODE B LT EHL aia A iA ie OTO ZER OE 13 6 3 ADD USER CODE 2 asa aloe EAP 14 6 4 ERASE USER GODE PIPBIM z S A R GA 14 6 5 BYPASS 2 15 6 6 ARM SIEENT CODE f B H ad da eae ee 16 6 E 16 6 8 17 6 9 BLODTPUTS CODE EE 18 6 10 POWER SUPPLY RESET CODE 9 ce ns 18 6 11 EVENTS FUNCTION 10 ONLY LCD KEYPAD eee a AO LARA 18 6 12 TESTING OUTPUTS AND LED INDICATORS ICGODEINI IS 18 6 13 SERVICE ACCESS CODE EL e Eo i 18 7 HISTORY OF MANUAL UPDATES 20 2 USER MANUAL CA 5 1 TECHNICAL RELIABILITY OF THE SECURITY SYSTEM The security system is built of technical devices the reliability of which is vital for effectiveness of the site protection The security
28. ialer which enables the security system to operate together with a monitoring station The control panel is intended for a variety of sites including apartments detached houses warehouses stores kiosks etc CA 5 SATEL 3 4 OPERATION This manual contains description of operating the CA 5 alarm control panel by means of the keypad Operating the security system consists basically in arming disarming the system switching the supervision on off and in adequate reaction to the information indicated by the control panel By means of the control panel keypad it is possible to trigger special alarms PANIC FIRE HELP to bypass the zones to establish communication with the service computer and also to control external electrical equipment such as electromagnetic lock fan lighting etc The keypad provides information on the security system status by means of 10 light emitting diodes LED and audible signals The LCD keypad provides information on the alarm system status by means of a liquid crystal display 2x16 characters three light emitting diodes LEDs as well as audible signals Fig 1 CA 5 KLED S keypad The LCD keypads are available in two versions i e CA 5 KLCD L and CA 5 KLCD S that differ in their overall dimensions and the display size The backlighting of keypad and display can be permanent or switched on automatically by pressing a key or alternatively by violation of any control panel z
29. icates the control panel is being programmed from the keypad ON the control panel is in the service mode press successively the 0 keys to return to the normal operating mode blinking slowly indicates entering the user functions menu blinking fast indicates entering the service user function reviewing the alarm trouble memory ULB red color LEDs indicating the status of system zones ON zone violated blinking fast alarm memory the zone triggered alarm but is not violated any more blinking very fast memory of the first violation vvhen armed the zone triggered alarm or was violated as first when armed but is not violated any more ON with a short extinguishment every 2 seconds detector tamper 2EOL zone type flashing every 2 seconds tamper memory detector was tampered 2EOL zone type blinking slowly zone bypassed indicated only with the partition disarmed Notes Depending on the options set the zone alarm memory is active until disarming and alarm clearing or until performing alarm log review with the system previously disarmed or alternatively until rearming the system If with the control panel armed an ENTRY EXIT or DELAYED zone is violated as the first one and then another zone triggers alarm the memory of the first alarm will be assigned to the zone which was violated first If after violation of an ENTRY EXIT or
30. it from the site The armed mode with automatic bypassing of the zones detectors assigned by the installer If after arming the system the user has not left the site and has not violated the entry exit monitoring line during the exit delay the selected zones of the control panel will be automatically bypassed and activation of the detectors connected to those zones will trigger no alarm 4 7 ARMING CODE The arming is only possible when the system is signaling no alarm and it is not in the armed mode the LA ALARM and lt gt ARMED LEDs are off In order to arm the system enter the user access code and confirm it with the key If you made a mistake when entering the access code press the key and re enter the code The access codes should be entered very carefully Three consecutive mistakes may trigger the alarm recorded in the events log as the 3 wrong codes alarm If the code is entered correctly and arming is possible the control panel will confirm the entry with four short beeps followed by a long one and will get armed In case the installer has pre programmed the exit delay the ARMED LED will start blinking to indicate beginning of that time countdown and arming will take place when the countdown is over The LCD keypad will display information about exit time delay The installer determines the length of the exit delay and the way the audible signaling works EXAMPLE Arming with the user ac
31. mbers of zones to be Eb bypassed in the LED keypad the LEDs 3 EP and 4 will light up in the LCD keypad digit 3 bal and 4 will be displayed accepting the entered data four short beeps and a long one signal end of the function Note The 24h zones which are on duty whether the system is armed or not can only be bypassed by means of the zone bypassing function accessible on entering the service code which ends with 16 USER MANUAL CA 5 6 6 ARM SILENT CODE 5 In the silent armed mode the alarms are not signaled on the OUT1 output and on the output programmed as BURGLARY ALARM They are only signaled in the keypad and by sending a message to the monitoring station EXAMPLE activating the silent armed mode user code 1230 1 2 3 0 calling the user function mode confirmed with three short beeps and in the LED keypad additionally slow blinking of the l PROGRAM LED 5 activating the silent armed mode four short beeps and a long one signal the end of the function in the LCD keypad this function may be called using arrow keys Note If a zone with activated PRIORITY option is violated or tampered than the control panel will refuse to perform this function 67 SETTME 000 R TCODET The function permits setting the control panel clock day month hour Present year is set by the installer vvith the service function The real indications of time and
32. odes to distinguish them from the other user codes e Access code No 4 action under duress disarming or alarm clearing by means of this code results in sending a special code to the monitoring station and activating the DUREss ALARM output access code cannot be changed with the user function 1 the code does not reset activity of the DURESS ALARM output e Access code No 5 does not disarm for other users permits disarming only when the same access code was used for arming the system which makes it possible to control block access to the site for the user who has such an access code at his disposal The installer has access to some of the user functions service code ending with However the service code cannot arm and or disarm the system set the service access time and add or delete the users 4 6 ARMED MODE OF THE CONTROL PANEL In order to adjust the security system to various situations the CA 5 control panel offers several armed modes 4 6 1 Full armed mode The operating mode when detectors connected to the control panel control the protected site and violation of the protected areas is signaled by the control panel with any available means monitoring sirens keypad CA 5 SATEL 7 4 6 2 Silent armed mode The supervision mode during which the alarms are transmitted to the monitoring station signaled in the keypad and on the KEYPAD ALARM type of output 4 6 3 Partial armed mode with no ex
33. one when in armed mode the manner of backlight operation should be determined by the installer The letters on number keys help the user memorize the code by associating it with a particular word e g the 2 6 2 7 2 code corresponds to the word COBRA o Satel Fig 2 LCD keypad for CA 5 control panel 4 USER MANUAL CA 5 Note Access to all functions of the control panel in version 2 10 is provided by LCD keypads in program version 1 08 and later and CA 5 KLED S keypads in version1 1 and later 4 1 LED FUNCTIONS The LED indicators inform the user about the security system status D ALARM red color the LED is on during alarm conditions and goes out after alarm L reset Blinking of the LED indicates there was an alarm in the system alarm memory ARMED green color the LED is on when the system is armed the LED can optionally extinguished by the control panel 3 minutes after arming Blinking of the LED indicates that exit countdown is running TROUBLE yellow color blinking of the LED indicates a trouble in the security system A The LED will be extinguished after the trouble cause is cleared or the function of current trouble checkup is executed key 7 function Re POWER green color the LED indicates the control panel power status ON mains supply and battery OK blinking low battery OFF loss ES PROGRAMMING red color the LED ind
34. ons described in this section are activated by entering the user access code and confirming it with the key not the key as is the case when arming the system 12 USER MANUAL CA 5 LED keypad The panel confirms entering the user function mode by the slowly blinking PROGRAM LED Next press the key with the number of selected function and then the key LCD keypad The panel confirms entering the user functions mode with three short beeps and displays the two first names out of the currently accessible user functions Satel cursor of function selection Fig 4 Fragment of user functions menu example To reach the required menu function press the key with selected function number or alternatively move the selection cursor up or down using the A V keys so that it indicates the suitable function The function is activated upon pressing the or gt keys When activated some functions require that data be entered or selection be made if this is the case the control panel waits for the user to take action a corresponding message will appear on the LCD display the PROGRAM LED will be blinking fast in the LED keypad USER FUNCTIONS MENU FUNCTION NR FUNCTION NAME Start DWNL starts panel programming by the phone from service computer Change access code Add user adds new user code Erase user deletes user code Bypass zones Arm silent activates silent armed mo
35. resent time but in the LED keypad it is possible to check the current hour and date set in the control panel In order to check the settings call the user function 6 and pressing the key twice look through the digits displayed on the LEDs from 2 to 5 as they were programmed The first digit is displayed immediately on calling the function CA 5 SATEL 17 Digits are presented in the binary code according to the table LED INDICATIONS 34185 O LED off LED on OO NO BB OI NM O 0 0 00 00 0010 0 08 8088 00 O0 O 0106868 00e 6e O O 0 08 0e O0 EXAMPLE checking the time and date of the panel clock user access code 1230 next to the keys are shown examples of LED indications 1 2 3 0 calling the user function mode confirmed with three short beeps and slow ei 000 HI OOee 000 NE blinking of the PROGRAM diode calling the number of the panel clock programming function confirmed with two short beeps and fast blinking of the PROGRAM diode The first digit 1 is displayed on the LEDs two long beeps the LED indications remain unchanged Note Pressing the keys will quit the function while for checking the date setting it is necessary to press the key 4 0000 0000 PUP going over to the date che
36. system elements are exposed to a variety of outside factors including the weather conditions outside sirens lightning overhead telephone lines power lines outside sirens mechanical damage keypads detectors etc Maintaining a high level of the security system reliability is only possible by current control of the functioning of particular devices The control panel is equipped with a number of safeguards and auto diagnostic functions intended for testing the system reliability The control panel signals trouble detection by p switching on the 44 TROUBLE LED on the keypad Such a situation requires an immediate response and if necessary consultation with the installer It is necessary to periodically test the security system functioning Make sure that the control panel reacts to violation of individual detectors that their field of vision is not blocked that there is a reaction to the opening of protected doors and windows and that the functioning of sirens and telephone monitoring is correct The installer should provide specific instructions on how the system should be tested It is recommended that periodical surveys be carried out by the installer as requested by the user The user in his own interest should anticipate unexpected alarm conditions and plan adequate procedures It is vital to be able to verify the alarm to determine its source based on the keypad information and to take appropriate measures e g to org
37. tion press the keys with numbers corresponding to the numbers of zones to be bypassed the LEDs or digits corresponding to the selected zones will on and confirm the selection with the key After bypassing the zones and quitting the user function mode in the LED keypad the corresponding LEDs start slowly blinking in the LCD keypad letters b will appear on the display in the fields corresponding to the bypassed zones The zones will remain bypassed until the next disarming or their manual unbypassing with the same function The unbypassing consists in extinguishing the LEDs digits which correspond to the bypassed zones Bypassing unbypassing a zone generates an event saved in the control panel memory Upon arming the indication of bypassed zones is switched off Bypassing the Arm Disarm type zones makes impossible the remote arming disarming of the system as well as the alarm clearing This operation must then be performed by entering the access code from the keypad code 12321 What to bypass 34 in the LED keypad additionally vvith slovv EXAMPLE bypassing the zones 3 and 4 user access Satel 111121312101 calling the user function mode confirmed with three short beeps and blinking of the PROGRAM LED us 2 4 calling the bypass zones function confirmed with two short beeps in the LCD D Satef keypad this function may be called usin 00 3 JUL 16 10 3141 selecting the nu
38. view function 5 3 CURRENT TROUBLE CHECK OUT 7 When the control panel signals a trouble detection the L TROUBLE LED is blinking holding down the 7 key until you hear a single beep will activate the Current Trouble Check out Function On activating the function the 2 PROGRAM LED will start blinking and the LEDs 1 to 5 will indicate any possible troubles from the first set list of troubles as per the table Pressing any key except for the key will change the set of displayed troubles to the other one which will be signaled by two short beeps Consecutive pressing of any key will display information alternately on the first set of troubles and on the second one Pressing the key will quit the function The meaning of the LEDs is as follows FIRST SET OF TROUBLES 230V AC power supply loss Battery trouble OUT 1 output trouble Power supply outputs trouble Clock loss SECOND SET OF TROUBLES No voltage on telephone line Problem with access to settings memory Wrong communication codes connections from computer blocked for 30 minutes by the panel Monitoring trouble Dialing error Note During the trouble memory review the extinguished LED No 3 asecond set trouble means Unsuccessful DWNL downloading The meaning described in the table refers to the current trouble check out only 5 3 1 Description of some trouble signaling causes 230V AC power supply loss th
Download Pdf Manuals
Related Search
Related Contents
SD-6980SY User Manual USER MANUAL - AJ Madison Electrolux AG17542STA User's Manual Use and maintenance manual - Hydro-Mec Portofino - Sanremo UK Samsung Galaxy Grand 2 manual de utilizador(KK) CTO Teminal - User Manual Copyright © All rights reserved.
Failed to retrieve file