Home

User manual - ES Documentation

image

Contents

1. However if you want to enter DISCHARGE or CYCLE modes you can press the BATT TYPE button to start NiMH blinking then press INC DEC buttons to scroll through the various modes Once the mode is settled like CYCLE short press ENTER to start values blinking for editing Below are the flow charts for all the settings in the charger Have a play with no battery connected to see how to set all the parameters for all supported battery types NiCd Mode GE Setting charge current Adjust and find the desired charge current which ranges from 0 1A to 5 0A with INC amp DEC buttons Press the ENTER button to confirm setting Setting discharge current Adjust and find the desired discharge current ranging from 0 1A to 1A with INC amp DEC buttons Press the ENTER button to confirm setting Setting discharge cutoff voltage This is the voltage that the charger should stop discharging the battery Adjust and find total discharge cutoff voltages to be discharged from 0 1V to 16 8V with INC amp DEC buttons Press the ENTER button to confirm setting Setting cycle This is to set cycling with two options Charge to Discharge Discharge to Charge Set cycling with INC amp DEC buttons and press the ENTER button to confirm setting NiMH Mode BATT TYPE N ENTER s555 C gt D 5 SETUP In C Setting charge current 3 0A Adjust and find the desired charge current which ranges from 0 1A to 5 0A with INC amp
2. DEC buttons Press the ENTER button to confirm setting Setting discharge current Adjust and find the desired discharge current which ranges from 0 1A to 1A with INC amp DEC buttons Press the ENTER button to confirm setting Setting discharge cutoff voltage This is the voltage that the charger should stop discharging the battery Adjust and find total discharge cutoff voltages to be discharged from 0 1V to 16 8V with INC amp DEC buttons Press the ENTER button to confirm setting Setting cycle This is to set cycling with two options Charge to Discharge Discharge to Charge Set cycling with INC amp DEC buttons and press the ENTER button to confirm setting Lithium Mode for 3 7V cell types only Setting Lithium battery capacity Adjust and set the desired battery capacity from 100mAh to 5000mAh with INC amp DEC buttons 50mAh per step Press the ENTER button to confirm setting Charge rate is set on the basis of selected capacity at 1C rate Example Li Po cell of 1500mAh capacity 1C 1500mAh 1 5A If your battery is larger than 5000mAh you can charge it at the 5000mAh setting but it will just take longer to finish charging Setting battery voltages for Lithium battery packs Select the total battery voltage to be charged or discharged with INC amp DEC buttons 1S 1S 3 7V single cell 2S 7 4V two cell series pack 3S 11 1 V three cell series pack 4S 14 8V fou
3. an error is detected In both cases the LBA tells the charger to shut down This insures maximum safety and saves the user from having to manually push the charger STOP enter button to stop the charge end or error tones The lithium battery should be disconnected from the LBA as soon as possible after charging is completed The DataPort version EOS chargers when connected to LBA10 balancer via cable HP EOSLBA10 DPC allow the user to monitor the individual voltages of each battery cell during the charge process This is an important addition to pack diagnostics as one is able to see the exact balance status of the battery pack or packs when LBA1O is in NET mode To view individual cell voltages after the balance charge has been started Connect DataPort Cable DPC between Charger and LBA10 as shown by the Green line in diagram below no matter if single or networked LBA connect DPC to Master LBA Push the EOS5i BATT TYPE Button for 3 seconds to access DATA screen Push the INC DEC buttons to scroll up and down data screens as in the chart below Series Adapter and Net Cable are from option pack HP EOSLBA10 MSC CHARGER DISCHARGER charger output charger output LBA 10 SLAVE H Balance Harness BATTERY T Main Leads Series Adapter gt Net Cable gt BATTERY o Main Leads LBA 10 MASTER E55 data port m hak DataPort Cable optional not required for
4. HYPERION EOS 5i DP AC DC User s Manual EOS Sia AC DC SPEED 5S14N Baa pres Comme orana Dual Input n lt gt gt Power with Ease HYPERION EOS 5i DP AC DC User s Manual Please read the following instructions carefully to insure safety and convenience EOS 5i DP_AC DC Special Features Two INPUT power choices Use AC 100 240V at home or DC 11 15V anywhere Powerful yet compact and portable with Wide support for various battery types Clear and easily readable LCD Screen with Warning messages for common setup errors Packaged in a rugged aluminum case Output harness included Long Input leads Specially designed to be 100 Compatible with Li Po PCM Guard and Balancer Adapters DataPort Interface for EOS LBA 10 Balancers see last page of manual for details Specifications Input voltage range Appropriate battery types and 1 14 Nickel Metal Hydride cells range of series connected cells 1 5 Lithium cells 100 5000mAh 3 7V cell type 100 240V AC OR 11 0 15 0V DC only one source may be connected at a time 1 14 Nickel Cadmium cells 1 6 Lead Acid cells 2V per cell nominal Charge current 0 1A 5A MAX by 100mA steps Discharge current 0 1A 1A MAX by 10mA steps Trickle charge current NiCd NiMH 0 200mA Charge termination zero delta V peak detection for NiCd NiMH CV CC for Lithium and Lead Acid Batteries Cycling Modes N
5. bare wire ends of the harness taking great care to observe proper polarity ALWAYS FOLLOW this connection sequence and reverse sequence to disconnect 1 Connect OUTPUT harness to the sockets located on the right side of the charger Take care that the Output Harness RED wire bullet connector goes to the socket and BLACK wire to 2a Connect Charger INPUT alligator clips to an appropriate DC power source a A 12V automobile battery b A quality low noise DC power supply of 12 15V with 5A rating large batteries may require 10A supply OR 2b Connect to AC wall power 100 240V using the supplied AC adapter cable DO NOT CONNECT BOTH AC AND DC INPUT AT THE SAME TI ME The Charger will display INPUT VOLTAGE error message if input voltage is out of range If this happens please recheck the input power supply to make sure correct voltage is present cens 3 Set the battery type using the charger cells configuration buttons The INC and DEC buttons are used to Increase or Decrease values such as Charge Current or LiPo Cell Count The INC and DEC buttons are used to select MODE such as Charge Discharge or Cycle The BATT TYPE and ENTER buttons both have two modes SHORT press or LONG 1 second press e Short press BATT TYPE Scroll battery types e Long press BATT TYPE View input output Data e Short press ENTER Scroll settings for a battery type Values will blink when selected If nothing is changed blinking wil
6. charging Balance Harness Data Display
7. h INC amp DEC button Press the ENTER button to confirm setting Displays during charge discharge and cycle CHG charge DCH discharge C D cycle D gt C cycle NC NiCd NM NiMH LP LiPo Pb Pb Completion display If the Enter button is pressed charge or discharge will be stopped In order to move back to the main display press the Enter button Data display INC INC DEC DEC If the Battery type button is pressed for over 3 seconds Data view will be displayed as above Data displays can be scrolled left and right by INC amp DEC buttons If nothing pressed for 3 seconds this display disappears Error messages When input voltage is below 11 0V or exceeds 15V Battery is not connected to the charger s output Battery is connected to the output in reverse When the output connection has some other problem When a battery becomes disconnected during an operation If incorrect voltages are set while charging lithium or Pb batteries If incorrect voltages are set or batteries are over discharged while charging Lithium or Pb batteries LBA DATAPORT FEATURE The DataPort is a 3 pin output which fits the option cable HP EOSLBA10 DPC See top label to locate the DataPort on the top left side of your EOS charger There are two main functions of the DataPort connection to LBA10 balance adapter The LBA communicates with the charger giving notification when balance charging is completed or when
8. iCd NiMH Charge gt Discharge and Discharge gt Charge Display type 2 line 16 backlit character LCD Safety precautions KEEP CHARGER AWAY FROM CHILDREN AND PETS AT ALL TIMES This charger is designed ONLY for NiCd NiMH Lithium 3 7V cell Lead Acid 2 0V cell type cells DO NOT attempt to charge other types such as 3 6V cell Lithium or non rechargeable batteries Always place the charger on a firm level and fireproof surface for charging Do not place the battery or charger on or near flammable materials while in use Keep away from carpets cluttered workbenches etc Do not exceed cell manufacturer s suggested max charge rates Do not use automotive type battery chargers to power the charger Do not leave the charger unattended while charging Disconnect the battery and remove input power from charger immediately if the charger becomes hot Allow the charger or battery to cool down before reconnecting Do not allow water moisture or foreign objects into the charger Do not open the charger nor attempt any repair It is dangerous and will void your warranty Do not obstruct the air intake holes on the charger ALWAYS follow correct connection sequence as given below CAREFULLY FOLLOW THE BATTERY PACK MAKER S RECOMMENDATIONS AND SAFETY ADVICE Using the EOS 5i DP AC DC The EOS 5i includes an Output Harness with two 4mm male banana connectors attached First solder your chosen battery connector to the
9. l stop Short press Enter until re selected then INC DEC to change values e Long press ENTER START charging or discharging or cycling Let s start by using a NiMh battery as an example When the charger is first connected to input power it will display the previously used battery configuration This is especially convenient if you often charge the same type of battery 1 If NIMH is not shown short push the BATT TYPE button to scroll through all battery types Stop when you reach NIMH 2 Short press the ENTER button to select C charge rate in Ampere 3 Press INC or DEC buttons to choose the proper rate for your battery pack Charging NiCd and NiMH is mostly automatic and the setup routines are the same for both You only need to consult the documentation for your battery pack or ask your dealer to determine the proper charge current in Ampere A If the rate is given in mA note that 100mA equals 0 1A so 900mA would be 0 9A for example 4 Attach your NiMH battery to the EOS 5i Output side harness checking that polarity is correct 5 Long press ENTER button hold down for about 1 second to begin charging NO BATTERY error if battery not connected OPEN CIRCUIT error if the battery becomes disconnected from the charger after START REVERSE POLARITY error if the battery is connected in reverse In our NiMH charging example above we pressed the ENTER button when NiMH was blinking to go directly to charge rate setting
10. r cell series pack 5S 18 5V five cell series pack NOTE The EOS Series chargers have intelligent detection routines to help you avoid making mistakes and LOW or HIGH VOLTAGE errors are displayed if battery voltage does not match your setting HOWEVER under some circumstances especially with over discharged or damaged batteries the safeguard could fail Therefore be absolutely sure that you have correctly set pack voltage correctly before charging every time Setting discharge parameters Adjust to the desired discharge current from 0 10A to 1 00A 0 01A per step with INC amp DEC button Press the ENTER button to confirm setting Set pack voltage 1S 5S as in charging example above Autocut occurs automatically at 3 0V per cell LITHIUM MODE IS ONLY FOR LITHIUM BATTERIES WITH 3 7V cell RATING Some Li Ion types are rated at 3 6V cell and CANNOT BE CHARGED with the EOS 5i Pb Mode lead acid battery BATT TYPE Back to NiCd Setting charge current Adjust and find the desired charge current which ranges from 0 1A to 5 0A with INC amp DEC buttons Press the ENTER button to confirm setting Setting total battery voltage for Lead Acid Battery Select the proper total battery voltage to be charged or discharged with INC amp DEC buttons 2V 4V 6V 8V 10V and 12V 2V per cell types only Setting discharge current Bee pan Adjust and find the desired discharge current from 0 10A to 1 00A 0 01A per step wit

Download Pdf Manuals

image

Related Search

Related Contents

Super Talent Technology 1TB RaidDriver II  Italian  Samsung Galaxy A5 Hướng dẫn sử dụng  Samsung DE46A  BakkerElkhuizen HandShoeMouse  データシート    Valueline VLSP40200B15 coaxial cable  Philips Wireless HiFi Headphone SBCHC8430  User Manual for the 820153 DC-DC Power Supply 150W  

Copyright © All rights reserved.
Failed to retrieve file