Home
Vista ABI Quick User Guide
Contents
1. Current Procedural Terminology CPT is copyright 2011 American Medical Association AMA All Rights Reserved No fee schedules basic units relative values or related listings are included in CPT The AMA assumes no liability for the data contained herein CPT is a registered trademark of the American Medical Association References to CPT codes herein are not intended to convey any endorsement or sponsorship by or affiliation with the AMA 11 File Management Save Recall Delete and Download Data Optional AVS Report Software is required to download data to PC SAVING AN EXAM Step 1 Perform an exam in any of the automated modes as described in the previous Quick Guides Exams can be stored in either numeric or alpha characters To change the filename configuration press the ENTER MENU key to open the OPTIONS menu and press the number 4 key to select NAME or NUMBER Press ENTER MENU to exit SYSTEM SETTINGS Step 2 Press the ENTER MENU key again to open the OPTIONS screen Press the number 3 key for File Management Press the number 1 key to select Save Current Exam to File There are 10 storage locations that retain data if power is lost Step 3 Press the number of a file location that is open When the area is highlighted enter the patient name or ID in the location using the numeric keypad Use the DOWN key to backspace and the UP key to toggle between letters on the same key Press the SAVE key to complete
2. a WALLACH brand 95 Corporate Drive Trumbull CT 06611 USA Phone 800 243 2463 Fax 203 799 2002 MKTO177 e Rev Ce 1 14
3. New Exam Keep Brachials to start a new exam on a current patient in which the brachial pressures can be used again DOWNLOADING AN EXAM AVS REPORT Note File to be downloaded was previously saved Step 1 Perform an exam in any of the automated modes as described in the previous Quick Guides or recall a previously saved exam DOWNLOADING AN EXAM AVS REPORT Note File to be downloaded was previously saved Step 1 Perform an exam in any of the automated modes as described in the previous Quick Guides or recall a previously saved exam Step 2 Set up the AVS Report software by double clicking on the application icon on the installed PC Consult the user manual if the AVS Report software has not already been installed on the PC Step 3 Connect the USB cable from the PC to the Vista ABI Step 4 Press the ENTER MENU key to open the OPTIONS menu Press the number 3 key for File Management Press the number 4 key for Download Exam from File Step 5 Press the number of a file location to recall and download Note Recalling a file will overwrite the current examination Save current data prior to recalling if desired To download all files at once use the UP or DOWN key to move the marker to DOWNLOAD ALL and press ENTER MENU Step 6 Data will be transferred to the AVS Report software Consult the Vista ABI User s Manual to save recall or export the AVS Report file to the PC 13 WALLACH SummitDibppler
4. Step 5 Move the hose to the right ankle and connect it to the cuff Step 6 Press and hold the PUMP key to inflate the cuff to 75 mmHg Release the PUMP key when the inflation automatically stops Pressure will deflate to 65 mmHg for optimum PVR Wait for the Cuff Deflating message on screen to disappear If needed use the SCALE key to optimize the waveform Step 7 After the waveform stabilizes press the FREEZE key to hold the waveform The pressure will automatically deflate from the cuff If the waveform is acceptable press the SAVE key Or use the UP or DOWN key to move the waveform to the optimum view and press the SAVE key Press SAVE again and the marker will move to the Right PT Step 8 Apply gel to the posterior tibial PT artery site and use the Doppler probe to listen to the blood flow Step 9 While holding the probe steady on the PT artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 10 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to move the caliper tool to the beginning of the returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to Right DP Step 11 Apply gel to th
5. Step 9 Switch the hose to the cuff at the left ankle and repeat steps 5 through 8 to obtain the left ankle waveform and DP or PT pressures Step 10 Switch the hose to the cuff at the left brachial site and repeat steps 1 through 3 to complete the exam The Vista ABI makes the hydrostatic correction based on the vertical distance entered prior to obtaining pressures The corrected values are displayed REPORT FORM RESULTS Step 1 Review the pressure corrected ABI values and waveforms Press the PRINT key to print the results Step 2 Peel the adhesive backing off the paper and apply to the report form Complete the report form by including the patient information Step 3 To save the exam to one of the 10 storage locations open the OPTIONS menu select FILE MANAGEMENT and save the current exam as described in Section 9 of the user s manual DUAL ANKLE PRESSURES After the current exam is either printed or saved a second ankle pressure to conform to CPT 93922 changes can be obtained Press ENTER MENU to open the OPTIONS menu and press the number 5 key to select NEW EXAM KEEP BRACHIALS Note A second ankle waveform is not necessary to complete the exam Press the ENTER MENU key again to open the OPTIONS menu and press the number 7 key for the hydrostatic correction Enter the vertical distance between cuffs in centimeters and press the SAVE key when finished Repeat steps 7 through 8 to obtain the second ankle pressures
6. menu Press the number 1 key for CONFIGURE EXAMINATION Press the number 1 key to select the ABI with PVR Waveform option Step 5 Press the ENTER MENU key again to open the OPTIONS menu Press the number 2 key for the SYSTEM SETTINGS menu Press the number 5 key to turn the Dual Ankle Pressure setting to OFF Press the number 6 key to use the DOPPLER probe to obtain pressures and press the ENTER MENU key to exit Step 6 Press the ENTER MENU key again to open the OPTIONS menu and press the number 7 key for the HYDROSTATIC CORRECTION Enter the vertical distance between cuffs in centimeters and press the SAVE key when finished SEATED ABI EXAM INSTRUCTIONS Step 1 Start at the right brachial artery site and connect the hose to the cuff Apply gel to the site and use the Doppler probe to listen to the blood flow Step 2 While holding the probe steady on the brachial artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 3 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to move the caliper tool to the beginning of returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to Right WAV Step 4 Move t
7. the storage process RECALLING A SAVED EXAM Step 1 Press the ENTER MENU key to open the OPTIONS menu Step 2 Press the number 3 key for File Management Press the number 3 key to Recall Exam Step 3 Press the number of a file location to recall Note Recalling a file will overwrite the current examination Save current data prior to recall if desired RESTORING DATA Step 1 Press the ENTER MENU key to open the OPTIONS menu Step 2 Press the number 3 key for File Management and press the number 3 key again for Recall Exam from File Step 3 Press the UP key to highlight Restore Data and press ENTER MENU to open the exam DELETING A SAVED EXAM Step 1 Press the ENTER MENU key to open the OPTIONS menu Press the number 3 key for File Management Press the number 2 key for Delete Exam from File Step 2 Press the number of a file location to delete Press that number key again to confirm file selection Step 3 Alternatively select DELETE ALL to clear the entire stored memory Press ENTER MENU to confirm or any other key to cancel 12 Attach Quick Guide to the basket for easy access STARTING A NEW EXAM Step 1 Press the ENTER MENU key for the OPTIONS menu Press the number 6 key for New Exam Clear All to clear all data and start a new exam You may enter a file name at this time using the keypad see Saving An Exam Alternatively press the number 5 key for
8. TTINGS Step 3 Press the ENTER MENU key to open the OPTIONS menu again Press the number 1 key for CONFIGURE EXAMINATION Press the number 3 key to select the TBI with PVR Waveform option Step 4 Wrap a cuff at each arm and ankle to prepare for the exam Typically use a 12 cm cuff for the arms and a 10 cm cuff for the ankles Wrap the digit cuff at the base of the Right great toe TBI EXAMINATION INSTRUCTIONS Step 1 Start at the right brachial artery site and connect the hose to the cuff Place the PPG probe on the index finger with the blue side of the probe against the skin The patient must remain still to acquire a PPG signal Step 2 Wait several seconds for the waveform to stabilize and press the SCALE key to properly size the waveform on the screen Once the waveform is stable press the PUMP key to inflate the cuff to approximately 20 mmHg above the pressure where the PPG pulsations disappear on the display Release the PUMP key and the cuff will automatically begin to deflate Step 3 When the first pulsation returns press the FREEZE key Use the caliper tool by pressing the UP or DOWN key to adjust the pressure reading Move the caliper to the beginning of the first upward slope at the start of the pulsation Press the SAVE key to save the systolic pressure and the marker will move to Right WAV Step 4 Move the hose to the ankle site and connect it to the cuff Step 5 Press and hold the PUMP key to inflate the cu
9. WALLACH Wallach works for you f Mi s Geen VistaABI v 3 1 edit Quick User Guide BA pa Doppler 9 D a WALLACH brand f MKTO177 e Rev C e 1 14 PUT WALLACH TO WORK IN YOUR PRACTICE We are pleased to provide this Vista ABI Quick User Guide which provides step by step setup and exam instructions for a number of studies performed by our Vista products We encourage you to affix this Quick User Guide to the product s basket for easy access to the Guide and its contents WALLACH SummitDpppler a WALLACH brand VistaABl USER GUIDE CONTENTS ABI with Doppler Pressures and PVR Waveforms Dual Pressures PerAnkie EE ABI with Doppler Pressures and Waveforms Dual Pressures PerAnkie amp 4 o ABI with PPG Pressures and PVR Waveforms Single Pressures Per Ankle Optional PPG Package is required for PPG pressures TBI with PPG Pressures and PVR Waveforms Single Pressure Per Anke Optional PPG Package is required to perform TBI exams Seated ABI with Doppler Pressures and PVR Waveforms Single Pressure Per Ankle 0 00 00 00 cee ene File Management Save Recall Delete and Download Data Optional AVS Report Software is required to download data to PC ABI with Doppler Pressures and PVR Waveforms Dual Pressures Per Ankle SETUP INSTRUCTIONS Step 1 Turn on the Vista ABI system by pressing the power button Step 2 Press the ENTER MENU ke
10. d Waveforms Dual Pressures Per Ankle SETUP INSTRUCTIONS Step 1 Turn on the Vista ABI system by pressing the power button Step 2 Press the ENTER MENU key to open the OPTIONS menu Press the number 2 key for SYSTEM SETTINGS Set Dual Ankle Pressure to either HIGH or LOW by pressing the number 5 key until the desired setting appears Press the number 6 key to select DOPPLER for obtaining the pressures then press ENTER MENU again to exit SYSTEM SETTINGS Step 3 Press the ENTER MENU key again to open the OPTIONS menu Press the number 1 key for CONFIGURE EXAMINATION Press the number 2 key to select the ABI with Doppler Waveform option Step 4 Wrap a cuff at each arm and ankle to prepare for the exam Typically use a 12 cm cuff for the arms and a 10 cm cuff for the ankles ABI EXAMINATION INSTRUCTIONS Step 1 Start at the right brachial artery site and connect the hose to the cuff Step 2 Apply gel to the right brachial artery site and use the Doppler probe to listen to the blood flow Step 3 While holding the probe steady on the brachial artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when the blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 4 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to
11. e dorsalis pedis DP artery site and use the Doppler probe to listen to the blood flow Step 12 While holding the probe steady on the DP artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 13 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to move the caliper tool to the beginning of the returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to Left WAV Step 14 Switch the hose to the cuff at the left ankle and repeat steps 6 through 13 to obtain the left ankle waveform and the left PT and DP pressures Step 15 Switch the hose to the cuff at the left brachial site and repeat steps 2 through 4 to complete the exam REPORT FORM RESULTS Step 1 Review the pressure ABI values and waveforms and press the PRINT key to print the results Step 2 Peel the adhesive backing off the paper and apply to the report form Step 3 Complete the report form by including the patient information Step 4 To save the exam to one of the 10 storage locations open the OPTIONS menu select FILE MANAGEMENT and save the current exam as described in Section 9 of the user s manual ABI with Doppler Pressures an
12. ff to 75 mmHg Release the PUMP key when the inflation automatically stops Pressure will deflate to 65 mmHg for optimum PVR Wait for the Cuff Deflating message on screen to disappear Step 6 After the waveform stabilizes press the FREEZE key to hold the waveform The pressure will automatically deflate from the cuff If the waveform is acceptable press the SAVE key Or use the UP or DOWN key to move the waveform to the optimum view and press the SAVE key Press SAVE again and the marker will move to the Right TOE Step 7 Move the hose to the digit cuff at the right great toe Apply the PPG probe to the underside of the toe opposite the toenail and above the digit cuff Wait several seconds for the waveform to stabilize and press the SCALE key to properly size the waveform on the screen Step 8 Once the waveform is stable press the PUMP key to inflate the cuff to approximately 20 mmHg above the pressure where the PPG pulsations disappear on the display Release the PUMP key and the cuff will automatically begin to deflate Step 9 When the first pulsation returns press the FREEZE key Use the caliper tool by pressing the UP or DOWN key to adjust the pressure reading Move the caliper to the beginning of the first upward slope at the start of the pulsation Press the SAVE key to save the systolic pressure and the marker will move to Left WAV Step 10 Switch the hose to the left ankle cuff and repeat steps 5 through 9 T
13. he hose to the right ankle site and connect it to the cuff Step 5 Press and hold the PUMP key to inflate the cuff to 75 mmHg Release the PUMP key when the inflation automatically stops Pressure will deflate to 65 mmHg for optimum PVR Wait for the cuff deflating message on screen to disappear If needed use the SCALE key to optimize the waveform 10 Step 6 After the waveform stabilizes press the FREEZE key to hold the waveform The pressure will automatically deflate from the cuff If the waveform is acceptable press the SAVE key Or use the UP or DOWN key to move the waveform to the optimum view and press the SAVE key Press SAVE again and the marker will move to Right ANK Step 7 Apply gel to either the posterior tibial PT artery site or the dorsalis pedis DP artery site and use the Doppler probe to listen to the blood flow While holding the probe steady on the chosen artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 8 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to move the caliper tool to the beginning of returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to Left WAV
14. he marker will then move to Left BRA Step 11 Switch the hose to the left brachial cuff and repeat steps 1 through 3 The marker will move to Right BRA at the completion of the exam REPORT FORM RESULTS Step 1 Review the pressure TBI values and waveforms and press the PRINT key to print the results Step 2 Peel the adhesive backing off the paper and apply to the report form Step 3 Complete the report form by including the patient information Step 4 To save an exam to one of the 10 storage locations open the OPTIONS menu select FILE MANAGEMENT and save the current exams described in Section 9 of the user s manual Seated ABI with Doppler Pressures and PVR Waveforms Single Pressure Per Ankle SETUP INSTRUCTIONS Step 1 Turn on the Vista ABI system by pressing the power button Step 2 The patient must sit erect in a chair so that the knees are at a 90 degree angle and feet rest flat on the floor or on an elevated platform The feet should not be dangling Wrap the cuffs around the arms and ankles Typically use a 12 cm cuff for the arms and a 10 cm cuff for the ankles Step 3 Using a tape measure or a yardstick measure the vertical distance in centimeters between the middle of the arm cuff to the floor and the middle of the ankle cuff to the floor Next subtract the ankle distance from the arm distance to acquire the vertical distance between cuffs Step 4 Press the ENTER MENU key to open the OPTIONS
15. l PPG Package is required for PPG pressures SETUP INSTRUCTIONS Step 1 Turn on the Vista ABI system by pressing the power button Step 2 Press the ENTER MENU key to open the OPTIONS menu Press the number 2 key for SYSTEM SETTINGS Ensure Dual Ankle Pressure is OFF by pressing the number 5 key until the setting is OFF Press the number 6 key to select PPG for obtaining pressures and then press the ENTER MENU key to exit SYSTEM SETTINGS Step 3 Press the ENTER MENU key again to open the OPTIONS menu Press the number 1 key for CONFIGURE EXAMINATION Press the number 1 key again to select the ABI with PVR Waveform option Step 4 Wrap a cuff at each arm and ankle to prepare for the exam Typically use a 12 cm cuff for the arms and a 10 cm cuff for the ankles ABI EXAMINATION INSTRUCTIONS Step 1 Start at the right brachial artery site and connect the hose to the cuff Place the PPG probe on the right index finger with the blue side of the probe against the skin The patient must remain still to acquire a PPG signal Step 2 Wait several seconds for the waveform to stabilize and then press the SCALE key to properly size the waveform on the screen Once the waveform is stable press the PUMP key to inflate the cuff to approximately 20 mmHg above the pressure where the PPG pulsations disappear on the display Release the PUMP key and the cuff will automatically begin to deflate Step 3 When the first pulsation returns press
16. move the caliper tool to the beginning of the returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to the Right WAV Step 5 Move the hose to the right ankle and connect it to the cuff Step 6 Apply gel to the posterior tibial PT artery site and use the Doppler probe to listen to the blood flow NOTE The ankle waveform can be obtained from either the PT artery or the dorsalis pedis DP artery Step 7 Once the desired waveform is obtained press the FREEZE key to hold the waveform Ifthe waveform is correct press the SAVE key Or use the UP or DOWN key to move the waveform to the optimum view and press the SAVE key Press SAVE again and the marker will move to the Right PT Step 8 While holding the probe steady on the PT artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 9 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to move the caliper tool to the beginning of the returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to the Right DP Step 10 Apply gel to the dorsalis pedis DP artery site and use the Doppler
17. probe to listen to the blood flow Step 11 While holding the probe steady on the DP artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when the blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 12 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to move the caliper tool to the beginning of the returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to the Left WAV Step 13 Switch the hose to the cuff at the left ankle and repeat steps 6 through 12 to obtain the left ankle waveform and the left PT and DP pressures Step 14 Switch the hose to the cuff at the left brachial and repeat steps 2 through 4 to complete the exam REPORT FORM RESULTS Step 1 Review the pressure ABI values and waveforms and press the PRINT key to print the results Step 2 Peel the adhesive backing off the paper and apply to the report form Step 3 Complete the report form by including the patient information Step 4 To save an exam to one of the 10 storage locations open the OPTIONS menu select FILE MANAGEMENT and save the current exam as described in Section 9 of the user s manual ABI with PPG Pressures and PVR Waveforms Single Pressures Per Ankle Optiona
18. rns press the FREEZE key Use the caliper tool by pressing the UP or DOWN key to adjust the pressure reading Move the caliper to the beginning of the first upward slope at the start of the pulsation Press the SAVE key to save the systolic pressure and the marker will move to Left WAV Step 9 Switch the hose to the cuff at the left ankle move the PPG probe to the underside of the left great toe and repeat steps 5 through 8 Step 10 Switch the hose to the cuff at the left brachial move the PPG probe to the left index finger and repeat steps 1 through 3 REPORT FORM RESULTS Step 1 Review the pressure ABI values and waveforms and press the PRINT key to print the results Step 2 Peel the adhesive backing off the paper and apply to the report form Step 3 Complete the report form by including the patient information Step 4 To save the exam to one of the 10 storage locations open the OPTIONS menu select FILE MANAGEMENT and save the current exam as described in Section 9 of the user s manual TBI with PPG Pressures and PVR Waveforms Single Pressure Per Ankle Optional PPG Package is required to perform TBI exams SETUP INSTRUCTIONS Step 1 Turn on the Vista ABI system by pressing the power button Step 2 Press the ENTER MENU key to open the OPTIONS menu Press the number 2 key for SYSTEM SETTINGS Press the number 6 key to select PPG for obtaining pressures Press the ENTER MENU key again to exit SYSTEM SE
19. the FREEZE key Use the caliper tool by pressing the UP or DOWN key to adjust the pressure reading Move the caliper to the beginning of the first upward slope at the start of the pulsation Press the SAVE key to save the systolic pressure and the marker will move to Right WAV Step 4 Move the PPG probe from the finger to the underside of the right great toe Move the hose to the ankle site and connect it to the cuff Step 5 Press and hold the PUMP key to inflate the cuff to 75 mmHg Release the PUMP key when the inflation automatically stops Pressure will deflate to 65 mmHg for optimum PVR Wait for the Cuff Deflating message on screen to disappear If needed use the SCALE key to optimize the waveform Step 6 After the waveform stabilizes press the FREEZE key to hold the waveform The pressure will automatically deflate from the cuff If the waveform is acceptable press the SAVE key Or use the UP or DOWN key to move the waveform to the optimum view and press the SAVE key Press SAVE again and the marker will move to the Right ANK Step 7 Wait several seconds for the waveform to stabilize and press the SCALE key to properly size the waveform on the screen Once the waveform is stable press the PUMP key to inflate the cuff to approximately 20 mmHg above the pressure where the PPG pulsations disappear on the display Release the PUMP key and the cuff will automatically begin to deflate Step 8 When the first pulsation retu
20. y to open the OPTIONS menu Press the number 2 key for SYSTEM SETTINGS Set Dual Ankle Pressure to either HIGH or LOW by pressing the number 5 key until the desired setting appears Press the number 6 key to select DOPPLER for obtaining pressures Press the ENTER MENU key to exit SYSTEM SETTINGS Step 3 Press the ENTER MENU key to open the OPTIONS menu Press the number 1 key for CONFIGURE EXAMINATION Press the number 1 key again for the ABI with PVR Waveform option Step 4 Wrap a cuff at each arm and ankle to prepare for the exam Typically use a 12 cm cuff for the arms and a 10 cm cuff for the ankles ABI EXAMINATION INSTRUCTIONS Step 1 Start at the right brachial artery site and connect the hose to the cuff Step 2 Apply gel to the right brachial artery site and use the Doppler probe to listen to the blood flow Step 3 While holding the probe steady on the brachial artery press and hold the PUMP key to about 20 mmHg above the occlusion pressure when blood flow is no longer audible Release the PUMP key and the cuff will automatically begin to deflate Step 4 When the arterial blood flow is audible again press the FREEZE key If the pressure is correct press the SAVE key If the pressure needs adjusting use the UP or DOWN key to move the caliper tool to the beginning of the returned pressure shown on the screen or enter the desired number from the keypad and then press SAVE The marker will move to the Right WAV