Home
Loop-O9400S SDH/SONET ADM/TM Features
Contents
1. Av UA Features 1U height full front access ETSI unit e 1US1 shelf STM 1 OC 3 e 1054 shelf STM 1 4 OC 3 12 Rack mount wall mount and stand alone Aggregate Lines e SIM 1 OC 3 software configurable e SIM 1 4 OC 3 12 software configurable Two hot swappable aggregate lines On board tributaries on TG1 slot Upto 16 E1 120 ohm T1 e Upto 16 E1 75 ohm Fixed tributary modules on TG2 and TG3 slots Up to two 16 E1 120 ohm T1 tributary modules e Upto two 16E1 75 ohm tributary modules e Upto six E3 T3 tributary modules for 1054 only Upto one 1 GbE FE EoS module with L2 switch for 1US4 only e Uptotwo 1 GbE or 4 FE EoS module without L2 switch Power Modules e Two hot swappable DC plug in modules 36 to 75 Vdc e Single AC plug in module 90 to 240 Vac AC and DC coexistent fixed module 90 to 240 Vac 36 to 75Vdc Two RS232 Asynchronous Networking Protection SNCP protection e MSP 1 1 protection for TM TM ADM cross connect VC11 VC12 VC3 VC4 cross connect External Internal Line timing with SSM Supports VCAT LAPS GFP BCP LCAS and non LCAS Supports jumbo frame Performance monitoring Alarm suppression masking and reporting Ethernet Order Wire EOW using VoIP technology note 1 Management e Console Port VT 100 menu driven SNMP Port e Centralized management with Loop s EMS INMS over DCC channel LoopView GUI E
2. where 101 is manufacture option used to select T1 E1 type for the Tributary Group1 TG1 slot must select one tg1 Description 8TE 8 1 1 120 ohm on board 8E75 8 E1 75 ohm on board 16TE 16 1 1 120 ohm on board 16E75 16 E1 75 ohm on board Note where 102 is manufacture option used to select a daughter card for the Tributary Group2 TG2 slot tg2 Description 16TE 16 1 1 120 ohm daughter card 16E75 16 E1 75 ohm daughter card 3TE3 3 E3 T3 daughter card with RF connector 1 0 2 3 75 ohm impedance 1GE4NSW 1 GbE over 155 622 Mbps SDH SONET signal daughter card without L2 switch 4FE4NSW 4 FE over 155 622 Mbps SDH SONET signal daughter card without L2 switch Note 1US4 version only The SA power option CAN NOT be used if you selected a 1GE4NSW or 4FE4NSW daughter card as a tg2 option AND 4EoS6SW or a 4EoS1SW daughter card as a tg3 option where tg3 is manufacture option used to select a daughter card for the Tributary Group3 slot tg3 Description 16TE 16 T1 E1 120 ohm daughter card 16E75 16 E1 75 ohm daughter card 4EoS6SW Ethernet Switch Daughter card with 4 LAN 1 GbE and SFE and 1 GbE WAN mapped to 155 622 Mbps SDH SONET EoS 4EoS1SW Ethernet Switch Daughter card with 4 LAN 1 GbE and 3FE and 4 8 FET WANs mapped to 155 622 Mbps SDH SONET EoS 1GE4NSW 1 GbE over 155 622 Mbps SDH SONET signal daughter card without L2 switch 4FE4NSW 4 FE over 155 622 Mbps SDH SO
3. 1SCSI68M G Ear Mounts 19 23 ear mounts Telecom Optional paper copy of User Manual A CD version of the manual is already included as standard package Optional paper copy of User Manual A CD version of the manual is already included as standard package AC power cord for Taiwan America AC power cord for Europe AC power cord for UK AC power cord for Australia AC power cord for China Order Wire VoIP Phone SIP Proxy Server Basic Software Note One SIP proxy server license supports up to 25 phone lines For phone lines exceeding 25 you need to purchase additional licenses for each increment of 25 lines One SCSI to sixteen RJ 1u height without cable 432x44x23mm WxHxD One SCSI to sixteen Wire Wrap 1u height without cable 432x44x40mm WxHxD One SCSI to sixteen BNC 1 5u height without cable 432x66x53mm WxHxD SCSI68 Male to one SCSI68 Male Length 200 cm Customer must provide a MAC address so that a license key can be generated to operate the software at that address Used for all Conversion Panels A pair of 19 23 ear mounts is supplied as part of standard package Note For other sizes please contact your nearest Loop sales representative where agg1 and agg2 are used to select aggregation line type 094005 SDH SONET ADM TM SDH SONET MSTP SFPC SFP mini GBIC housing plug in card without SFP module Order SFP modules separately from SFP module brochure
4. MS SD Line Alarm MS SF MS AIS MS RDI MS BIP UAS MS REI UAS Ho Path AU LOP AU AIS HP SD HP SF HP UNEQ HP PLM HP RDI S HP RDI C HP RDI P HP BIP UAS HP REI UAS LOM Lo Path TU LOP TU AIS LP SD LP SF SONET Line LOS PI LOF S TIM S BIP S UAS SD L SF L AIS L RDI L BIP L UAS REI L UAS STS Path LOP P AIS P SD P SF P TIM P UNEQ P PLM P RDI S P RDI C P RDI P P BIP P UAS REI P UAS LOM VT Path LOP V AIS V SD V SF V Alarm Queue Contains up to 200 alarm records of latest alarm types alarm severity date and time Alarm Input Output Inputs Outputs Channel 4 Channel 4 Connector RJ45 Connector RJ45 Internal Resistance 1K Initial Insulation Resistance Min 100M ohm at 500Vdc Activation Current 3 ma Maximum switching voltage 110 V DC 125 V AC Deactivation Current 1 5 ma Allowable Current 4ma Power AC module 100 to 240 Vac 50 60Hz DC module 48 Vdc 36 to 75 Vdc and DC coexistent module 100 240 Vac 50 60 2 36 to 75 Vdc Power Consumption Loop 09400S 1US1 Max 24 6 W AC Max 25 7 W DC amp AC Max 27 5 W Loop 09400S 1US4 DC Max 39 6 W AC Max 43 9 W DC amp AC Max 47 1 W Physical and Environmental Dimensions for 1u 432 x 44 x 240 mm W x H x D Temperature 0 to 50 C Humidity 0 95 RH non condensing Mounting 19 inch rack mountable and wall mountable Standards Compliance ITU G 664 G 707 G 7041 G 7042 G 775 G 783 G 806 G 823 G 7
5. 1 0 2 3 75 ohm impedance 75 ohm coax Bellcore GR 499 core ITU G 824 Unframed RF connector 1 0 2 3 75 ohm impedance 75 ohm coax Two ports in one DB9 female nx VC12 n x VC11 n x VC3 or n x VC4 RJ45 nx VC12 n x VC11 n x VC3 or n x VC4 RJ45 2 aggregate lines clocks East STM 1 4 OC 3 12 West STM 1 4 OC 3 12 3 tributary clocks 1 external input and output clock 2 048 MHz of ITU T G 703 or E1 for STM 1 4 T1 for OC 3 12 Multi color LEDs Electrical RS232 Connector DB9S female DCE Protocol Menu driven VT 100 SNMPv1 RFC1213 Using 1 E1 Using DCC channel user selectable 3 9 or 12 channels Direction to optical lines to tributary lines Optical interface Direction to optical lines Direction to optical lines to tributary lines TE1 interface Direction to optical lines to tributary lines Direction to optical lines to tributary lines interface Direction to optical lines to tributary lines 094005 SDH SONET ADM TM SDH SONET MSTP Performance Monitor Performance Performance Parameters Error Block EB Background Block Error BBE Error Second Reports ES Burst Error Second BES Severe Error Second SES Unavailable Second UAS Alarm History System Alarm Alarm Cut Off Power Loss TS Sync Loss SNCP Switch MSP Switch Login Logout FOM Equip Unequip SFP Tx Fail SFP Rx Fail SFP Temperature SDH SONET SDH Line PI LOS RS LOF RS TIM RS BIP UAS
6. 47 X 86 ANSI T1 105 71 107 IEEE 802 1q VLAN 802 1w RSTP 802 15 MSTP 802 1ad stack VLAN 802 3x flow control 802 1p QoS IETF RFC2236 IGMP Snooping RFC1213 SNMPv1 Certification EMC EN55024 EMI EN55022 Class A FCC Part 15 Class A EN55024 Safety EN60950 1 IEC60950 1 Loop O9400S SDH SONET ADM TM SDH SONET MSTP 094005 Front Panels Single AC Power Plug in Module Single AC and DC coexistent Fixed Power Module 1US4 Tributary Tributary Group 3 Group 2 Alarm IN OUT Slot DC power Aggregate SNMP RS232 Console Tributary hot swappable Lines Port Group1 plug in modules Ext E1 T1 Clock 1US1 Tributary Tributary Alarm IN OUT Group 3 Slot Group 2 Slot TET Single AC and DC Aggregate Lines Ext RS232 Console Tributary Group coexistent Fixed Clock Port Power Module SNMP 1 1 1 Panel View of Plug in Cards 8TE 8E75 16TE 16E75 1GE4NSW 4EoS1SW Telecom Loop O9400S SDH SONET ADM TM SDH SONET MSTP Application Illustration C SDH SONET backbone STM 1 4 OC 3 12 O9400R E3 T3 1 1 E3 T3 a E1 T1 heni STM 1 4 A Ethernet OC 3 12 09100 Ring Waaa O9400S YA 09100 094006 E3 T3 Nawe9 Ethernet T i T elec Loop O9400S SDH SONET ADM TM SDH SONET MSTP Loop 09400S Tributary Type and Capacity Reference Tab
7. MS Element Management System e Loop iNMS with full FCAPS and end to end circuit management e Telnet support e SSH RoHS compliant Loop 09400S SDH SONET ADM TM Description Loop 09400S ADM TM is a compact economic STM1 4 OC 3 1 2 ADM amp TM multiplexer designed to add and drop up to note lt 1US1 shelf STM 1 OC 3 48 E1 T1 tributaries 2 GbE tributaries 8 FE tributaries 1054 shelf STM 1 4 OC 3 1 2 48 E1 T1 tributaries 6 E3 T3 tributaries 2 GbE tributaries 8 FE tributaries With up to two aggregate STM 1 4 OC 3 12 interfaces the Loop O94008 can offer the service provider a versatile protection scheme including SNCP and MSP 1 1 protection for both ring and linear network topology All interfaces are fully compliant with the relevant ETSI standards and ITU recommendations The Loop O94008 provides powerful OAM amp P Operation Administration Maintenance and Provisioning functionality including fault management performance monitoring configuration management and network security management Through the console port LAN port Inband E1 and DCC channel the OAM amp P can be achieved both locally and remotely via SNMP or menu driven interfaces Powerful SDH Loop s EMS NMS The Loop O94008S provides a complete set of operation interfaces that are consistent with the Telecommunication Management Network TMN concept ITU Recommendation M 30 G 784 for SDH SONET Network Element Ope
8. NET signal daughter card without L2 switch daughter card with RF connector 1 0 2 3 75 ohm impedance where 1 is used to select 1st power supply Note Available for 1US4 version only The SA power option CAN NOT be used if you selected a 1GE4NSW or a 4FE4NSW daughter card as a tg2 option AND a 4EoS6SW ora 4EoS1SW daughter card as a tg3 option 1US4 version only Note AD is a fixed power supply If you order AD then you cannot select any items for pp2 For AC power module choose an appropriate power cord If you order SA then you cannot select any items for pp2 CAN NOT be used if you selected a 1GE4NSW a 4FE4NSW daughter card as a tg2 option AND a 4EoS6SW ora 4EoS1SW daughter card as tg3 option For AC choose an appropriate power cord 1 Description AD AC and DC co existent fixed power module 90 to 240 Vac 36 to 75Vdc SA Single AC plug in power module 90 to 240 Vac 50 60 2 SD48 Single hot swappable DC plug in power module 48 Vdc m z EP WAVAVAVA Telecom Can order up to two power modules for 094005 SDH SONET ADM TM SDH SONET MSTP 1 Description Note 36 to 75Vdc Redundancy where pp2 is used to select 2nd power supply pp2 Description Note SD48 Single hot swappable DC plug in power module 48 Vdc order up to two power modules for 36 to 75Vdc Redundancy SA Power option for Ethernet Cards Refe
9. SI II 68 pin feet E3 Interface Line Rate 34 368 M bps 20ppm Output Mask ETS 300 689 Sec 4 2 1 2 ITU G 703 Line Code HDB3 Jitter ITU G 823 Input Signal ITU G 703 Framing Unframed ya Telecom 094005 SDH SONET ADM TM SDH SONET MSTP Output Signal T3 Interface Line Rate Line Code Input Signal Output Signal RS232 Interface Rate ITU G 703 44 736 M bps 20ppm B3ZS ITU G 703 ITU G 703 up to 19 2K bps Asynchronous Fast Ethernet FE interface Line Rate Layer2 Protocol Process Protocol 10 100M bps RSTP 802 1w VLAN 802 10 802 1 Flow Control 802 3x MSTP 802 1s IGMP Snooping RFC2236 QoS 802 1 VCAT GFP G 7041 LAPS BCP LCAS G 7042 and non LCAS Gigabit Ethernet GbE interface Line Rate Layer2 Protocol Process Protocol System Clock Clock Source Management LEDs Console port Telnet SNMP Inband interface Outband interface Diagnostics Mainboard Loopback Test BERT Test 1 card Loopback Test BERT Test TE3 card Loopback Test BERT Test 10 100 1000Mbps 1GE4NSW only supports 1000Mbps RSTP 802 1w VLAN 802 10 802 1p Flow Control 802 3x MSTP 802 1s IGMP Snooping RFC2236 QoS 802 1 VCAT GFP G 7041 LAPS BCP LCAS G 7042 and non LCAS Internal clock Connector Impedance Output Mask Jitter Framing Connector Impedance Connector Mapping Connector Mapping Connector RF connector
10. le 1US4 Max aroup Capacity IGT 48E1 T1 6E3 T3 2 GbE 1 GBE and 3 FE Note The maximum capacity of the tributary cards is one STM4 1US1 Max Capacity 48E1 T1 Note The maximum capacity of tributary cards is two STM1 WATANI YTA Telecom Loop O9400S SDH SONET ADM TM SDH SONET MSTP Loop O9400S Aggregate Line and Capacity Reference Table 1US4 1US1 2 STM 1 4 OC 3 12 for ADM 2 STM 1 4 OC 3 12 for TM 141 2 STM 1 4 OC 3 12 for 2 TM 2 STM 1 OC 3 for ADM for TM 141 2 STM 1 OC 3 for 2 TM EP uk TET 1 pleci mua EEE a E EH Gw ss l elecom 094005 SDH SONET ADM TM SDH SONET MSTP Block Diagrams 1US4 Model 1US1 Model J Oop LOOP TELECOMMUNICATION INTERNATIONAL INC ISO 9001 ISO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Hsinchu Science Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China 886 3 578 7696 886 2 2659 0399 1 561 627 7947 86 22 8789 4027 www looptelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2012 Loop Telecommunication International Inc All Rights Reserved Version 25 23 March 2012 Subject to change without notice WAVATA Telecom
11. rations System NE OS NE NE and NE Craft communications Users can easily operate the Loop 09400S both locally or remotely for centralized management Note 1 Enquire Loop for detail Note 2 Detail on Tributary Type and Capacities are found on pages 14 and 15 Future option 094005 SDH SONET ADM TM SDH SONET MSTP Ordering Information To specify options choose from list below Note All 094005 units plug in modules and accessories are ROHS compliant If a different environment requirement is needed please contact Loop s Sales team regarding availability Model Main Unit Loop 09400 S 1US4 agg1 agg2 tg1 tg2 tg3 pp1 pp2 G Loop O9400 S 1US1 agg1 agg2 tg1 tg2 tg3 pp1 pp2 G Plug in Card Loop O9400 S SFPC G Accessories SFP Optical Modules Description 1U height shelf with STM 1 4 OC 3 12 engine 1U height shelf with STM 1 OC 3 engine SFP mini GBIC housing plug in card without SFP module Note Order one or two cards Please place your order using the 5 digit alohanumeric codes listed in the separate SFP Optical Module Brochure User s Manual Loop O9400 S UM 1US4 Loop O9400 S UM 1US1 Power Cord Loop ACC PC USA Loop ACC PC EU Loop ACC PC UK Loop ACC PC AUS Loop ACC PC CH Order wire phone Loop O9400 S OW G SIP Proxy Server Loop O9400 S SIP Conversion Panels Loop ACC P 1SCSI 16RJ G Loop ACC P 1SCSI 16WW G Loop ACC P 1SCSI 16BNC G Conversion Cable Loop ACC CAB SCSI68M 200
12. rence Table SA power option TG2 TG3 16 16E75 3TE3 1US4 only 4EoS6SW 4EoS1SW 16 16E75 3TE3 1US4 only 1GE4NSW 4FE4NSW 16TE 16E75 3TE3 1US4 only 1GE4NSW 4FEANSW Comparison of Slots between 1US1 and 1US4 1US1 1US4 01 8TE 8E75 16TE 16E75 the same with 1051 Tg2 Does not support 3TE3 All Tg3 Does not support 3TE3 4EoS6SW 4 515 All Loop O9400S SDH SONET ADM TM Product Specifications SFP Module Characteristics please refer to SFP optical module brochure for detail Max Number of Cross Connect Modules 1US1 Shelf STM 1 OC 3 2 STM 1 OC 3 aggregate lines 1US4 Shelf STM 1 4 2 STM 1 4 OC 3 12 aggregate lines OC 3 12 Max Number of Tributary Modules 1US1 Shelf STM 1 OC 3 48 E1 T1 tributaries 2GbE tributaries 8FE tributaries 1054 Shelf STM 1 4 48 E1 T1 tributaries OC 3 1 2 2 E3 T3 tributaries 2 GbE tributaries 8 FE tributaries Tributary Modules E1 Interface Line Rate 2 048 M bps 50 ppm Output Mask ETS 300 689 Sec 4 2 1 2 ITU G 703 Line Code AMI HDB3 Jitter ITU G 823 Input Signal ITU G 703 Framing Unframed Output Signal ITU G 703 Impedance 75 ohm coax 120 ohm twisted pair Connector One SCSI II 68 pin T1 Interface Line Rate 1 544 M bps 32 ppm Output Mask Bellcore GR 499 core Line Code AMI B8ZS Jitter ITU G 824 Input Signal DSX 1 0dB to 6dB w ALBO Framing Unframed Output Signal DSX 1 w short haul 0 133 Impedance 100 ohm 133 266 266 399 399 533 533 655 Connector One SC
Download Pdf Manuals
Related Search
Related Contents
Cables Direct DisplayPort, 1m ISTRUZIONI PER L`UTILIZZO DELLA VASCA A TINOZZA IN LEGNO Supermicro P8SGA Hyundai D42EMA Ï * D1 Chptr - Moose Peterson - Ana Important! Please ensure the DC Plug is inserted to match the Digital Delay effektpedal bedienungsanleitung BEDIENUNGSANLEITUNG Copyright © All rights reserved.